Halton Marine HVAC solutions for refurbishments

Size: px
Start display at page:

Download "Halton Marine HVAC solutions for refurbishments"

Transcription

1 Halton Marine HVAC solutions for refurbishments FOR ENERGY-EFFICIENT, COMFORTABLE AND SAFER INDOOR ENVIRONMENTS Enabling Wellbeing

2 Contents Creating added value for owners Considering refurbishment? Galley reburbishment M.A.R.V.E.L. demand-based ventilation Control systems for galley ventilation Cabin refurbishment Demand-based cabin ventilation Cabin HVAC supervision system Fire dampers Droplet separators Services Photo: courtesy of MSC Cruises HVAC solutions for refurbishment projects

3 Creating added value for owners It can be estimated that 30% of the total energy consumption of a cruise ship comes from HVAC for galley ventilation, accommodation and public spaces. This has a major impact on profitability and environmental issues. Let us help you with industry leading solutions that are also available for refurbishment projects. WE ENCOURAGE YOU TO INVEST IN TECHNOLOGY THAT WILL PROVIDE YOUR BUSINESS WITH ENERGY-EFFICIENT, DEMAND-BASED VENTILATION THAT COMES WITH AN INTELLIGENT OPERATION SYSTEM 3

4 Halton is passionate about indoor environments. We offer business enhancing solutions for comfortable, energy-efficient and safe environments, for companies that value wellbeing and productivity of their customers and personnel. HVAC solutions for refurbishment projects

5 Halton scope of supply Considering refurbishment? Ships are required to dry-dock every now and then. Major overhauls usually extend the ship s life cycle, attract new passengers and create an opportunity to upgrade the ship with modern up-to-date solutions. Halton Marine, the leading suppliers of marine HVAC, develops, manufactures and markets, reliable, high-quality ventilation solutions specifically designed for shipbuilding, naval vessels and the oil & gas indusry. The following pages introduce you to our refurbishment solutions and products. Halton Marine HVAC Audit A succesful dry-docking requires a great deal of planning and some serious decisions concerning what should and can be done. Prior to the dry-docking, Halton Marine can offer an HVAC Audit for galley and cabin ventilation the areas that use a substantial part of the ship s HVAC. Based on the HVAC Audit, Halton Marine draws up a report on the upgrades, improvements and solutions it recommends in order to have a better functioning system. When these improvements have been carried out, Halton Marine conducts another survey to compare the results to the original values and to verify the results. Halton currently operates in 24 countries. In addition to Halton's own personnel, an extensive network of Halton distributors and agents are at your service. Let us help you with industry leading solutions and services 5

6 Galley refurbishment IMPROVEMENT? CONSUME LESS ENERGY WITH CAPTURE JET The Capture Jet technology in Halton hoods prevents the heat and impurities produced by cooking appliances from spreading to the work area. Compared to conventional exhaust-only hoods, Capture Jet is up to 30% more efficient and it reduces required airflow thus saving weight, space and energy consumption. The Halton Capture Jet technology does not necessarily require a separate supply air duct. The Capture Jet Fan takes the required air from the galley. This saves space as well as refurbishment and operational costs. UV LIGHT TECHNOLOGY SPEAKS FOR ITSELF The UV light technology is an excellent choice, not only for new building but also for refurbishment projects as Halton s solution doesn t affect the outer dimension of the hood. UV light is the most efficient grease filtration technology in the market that also helps to reduce fire risks and the need for the expensive cleaning of the ducts. The pictures on the next page speak for themselves. HVAC solutions for refurbishment projects

7 SUPPLY AIR / Halton KWT hood includes a supply air panel. Halton Marine also manufacturers low velocity ceiling diffusers (TCG) for galleys. ASHRAE recommends using low velocity ceiling diffusers in galleys. AUTOMATIC WASHING / Halton water wash hoods are equipped with an automatic washing system that cleans the filters, UV lamps and exhaust plenum at the set time. UV-LIGHT EFFICIENCY/ Indisputable filtration efficiency. Above: hood damper of a hood that uses UV light technology. Below: hood damper of a hood without UV light technology. WET CHEMICAL FIRE SUPPRESSION SYSTEM / Certified wet chemical fire suppression systems available as a factory installation. CAPTURE EFFICIENCY/ Halton Capture Jet prevents the heat and impurities from spreading into the work area. CONSTRUCTION / Continuosly welded construction. Halton KWH and KWT hoods include an in-built certified fire damper in the exhaust connection. GALLEYS 7

8 Save this Airflow Consume only what is strictly needed M.A.R.V.E.L. Demand-Controlled Ventilation Operating Day IMPROVEMENT? UP TO 50% ENERGY SAVING COMBINED WITH CAPTURE JETS Halton offers a unique system that can save significant amount of energy in galleys without compromising the comfort and functionality. Halton s patented method of Demand-Controlled Ventilation called M.A.R.V.E.L. adjusts hood exhaust airflow based on the status of the cooking appliance. This is done automatically and individually for each hood. AVAILABLE FOR REFURBISHMENT PROJECTS In conventional systems, galley ventilation is maintained at a constant level, which has been designed for the highest expected level. In the Halton system, the exhaust and supply air volumes of the ventilation vary according to real need. The system detects the status of cooking equipment by using sensors and an algorithm designed for galley application. M.A.R.V.E.L. also provides comfortable conditions by supervising and maintaining the humidity and temperature levels inside the galley by adjusting the supply and exhaust fans. The result of M.A.R.V.E.L. system is an optimized energy consumption according to real need. HVAC solutions for refurbishment projects

9 AIR HANDLING UNIT Te P CALCULATOR EXHAUST FAN SUPERVISOR DAMPER REGULATION IR Te RH M.A.R.V.E.L. TECHNOLOGY/ The system continuously measures the actual status of each piece of galley equipment, whether switched off, heating up, or in the process of cooking and adjusts the exhaust and supply air flow rates automatically according to demand. GALLEYS 9

10 Intelligent control systems for galley ventilation IMPROVEMENT? USER-FRIENDLY INTERFACE MANAGING ALL INNOVATIVE TECHNOLOGIES The touch screen is the heart of the galley ventilation control system. It has been developed to handle and manage all the innovative Halton galley ventilation technologies such as the UV light technology, water wash system and demand-based ventilation system M.A.R.V.E.L.. The FCP touch screen is easy to use due to the visual displays. The screen displays individual hoods with clear pictures and shows the hood statuses. The system enables the naming of different hoods connected to the control cabinet in order to improve understanding of what is going on in the galley. If the hoods utilize M.A.R.V.E.L. demand-based ventilation technology, the touch screen gives feedback on energy efficiency and compares it to the system without M.A.R.V.E.L. The FCP touch screen that can be integrated on control cabinet or even inside the chef's office, can manage up to 32 hoods (depending on the integrated technology). HVAC solutions for refurbishment projects

11 ON / OFF SWITCH FIRE SWITCH EMERGENCY STOP HALTON FCP TOUCH SCREEN / The touch panel interface has been developed to provide a fast and visual approach to the technical ventilation installation, even for nontechnically skilled personnel. PWR HALTON UCS CONTROL PANEL / The Halton UCS control panel is a small and compact monitoring and controlling panel for galley hoods that are equipped with UV light technology. The panel can be integrated e.g. in the front panel of the hood, hood surface or control cabinet door. The control panel indicates the status of the UV light, running hours and possible maintenance calls. PWR PLEASE NOTE: CONTROL CABINETS / Halton Marine supplies several types of control cabinets according to the customers' needs. Different control panel options are shown in the picture but the panel type is selected according to the customers' needs. GALLEYS 11

12 Cabin refurbishment IMPROVEMENT? MODERN, UP-TO-DATE SOLUTION FROM RELIABLE SUPPLIER The Halton Marine cabin ventilation solution is a total package that is specifically designed for different types of cabins and other spaces that require a good and efficient air-conditioning. The package includes a VAV or FCU unit with plug and play functionality, plus grilles, diffusers and valves. The VAV unit with intelligent automation can operate as stand-alone unit or in a network which enables additional features. Halton Marine is your partner when you need to upgrade your cabin ventilation system with modern up-to-date solution. We offer you the possibility to save in energy consumption, a possibility to control, monitor and adjust cabin indoor climate centralized via network (available also for hotel management) as well as a decreased possible trouble shooting time. TERMINAL UNITS / Halton Marine complete cabin ventilation package offers a selection of cabin units as well as fancoils for different types of cabins. HVAC solutions for refurbishment projects

13 DIFFUSERS / Fully integrated DLQ. Halton offers several diffuser models for different types of cabins. Photo: courtesy of MSC Cruises ROOM THERMOSTATS / Halton LCD room thermostats are available with customized background pictures and with several frame options. GRILLES / Golden grille. Halton offers several grille types with different types of finishing. CABINS 13

14 Demand-based cabin ventilation IMPROVEMENT? UP TO 35% ENERGY SAVINGS WITHOUT LOSING ANY COMFORT EFURBISHMENT PROJECTS Halton offers energy efficiency solutions for cabins by providing local and advanced energy efficiency systems. Local energy efficiency solution Air-conditioning is forced into standby mode when the passenger removes the keycard from its holder. Even though unnecessary cooling and heating is limited while the cabin is not occupied, the indoor climate conditions are simply maintained at a comfortable level. The individual comfort level is quickly re-established when the passenger returns to the cabin. If the passenger opens the balcony door, the cabin ventilation unit saves energy by preventing unnecessary cooling. With local technology, it is possible to achieve savings up to 8% (VAV or FCU unit) in cabin HVAC energy consumption. Unlike the advanced system, the local solution for energy efficiency does not require a network. Advanced energy efficiency solution (VAV) One of the best benefits from the owner's point of view is active operation between AHU (Air Handling Unit) and terminal units. Data from terminal units is collected, calculated and used to control the AHU in two ways: 1. Adjusting the fan operation to optimal level Data from the terminal units is collected, calculated and used to control the AHU's fan speed. 2. Minimizing the need to cool down the air inside the AHU Based on the terminal unit reheater's utilization rates, AHU's cooling and heating valves are controlled to prevent unnecessary air-conditioning. This also minimizes unnesseary electrical heating inside the terminal unit. With Halton Marine's advanced energy efficiency technology, it is possible to save up to 35% in cabin HVAC energy consumption. HVAC solutions for refurbishment projects

15 AIR HANDLING UNIT CALCULATOR CABIN UNIT Photo: courtesy of MSC Cruises BALCONY DOOR SWITCH CABINS 15

16 Monitor your cabin comfort and savings IMPROVEMENT? EASY ADJUSTMENT, CONTROL AND MONITORING VIA NETWORK Halton Marine cabin units / fancoils can be connected to a network (LON or Ethernet) in order to improve energy efficiency and implement the Halton supervision system (SCADA). Halton SCADA (Supervision, Control, and Data Acquisition) is a system that controls a total cabin ventilation system. Ventilation units (VAV cabin units or FCU fancoils) are easy to connect to the existing Ethernet network with Halton network adapters. The Halton Marine supervision software runs on a computer and offers an excellent tool for HVAC engineers and hotel management. The software offers an overview from a cabin ventilation system, to each cabin that can be individually adjusted, controlled and monitored via network. The software enables the changing of parameters and set-points, for individual cabins or for cabin groups, as well as printed listings of different elements that have a direct impact on indoor climate conditions, safety and energy-efficiency. The supervision system can also display the history data and trends. Symbolic representation of the process and clear displays make the software easy and convenient to use. HVAC solutions for refurbishment projects

17 ROOM TEMPERATURE CONTROL PANEL (º C.) CABIN UNIT HALTON Terminator OR FANCOIL NETWORK ADAPTER PRINCIPLE DRAWING / Main components of LON or Ethernet network. LONAC LONAC 914 LONAC RPU BUSAC : 16 m LAN LONAC RPU BUSAC : 12 m LONAC RPU RPU BUSAC : 33 m LONAC RPU RPU NETWORK ARCHITECTURE / Halton Marine offers its services for designing the BUSAC : 12 m network architecture rminator C 914 RPU LONAC AHU PLC CALCULATOR BUSAC : 18 m (OPTIONAL) ILONAC Terminator 507 Terminator LON 108 RPU AC : 3 m LONAC BUSAC : 12 m RPU BUSAC 704 : 33 m 504 LONAC RPU BUSAC : 8 m BUSAC : 23 m BUSAC : 22 m AC VAC VAC VAC VAC VAC SCADA (HMI) IBRA AC rminator FIBRA ILONAC BUSAC : 18 m FIBRA FIBRA ILONAC Balcony door list Key card list Balcony door & key-card list ILONAC Terminator FIBRA ILONAC Energy saving Cp local mode Cp remote set point Cp middle position Terminator FIBRA ILONAC Terminator LONAC Terminator RPU PRINCIPLE MIMICS OF HALTON SOFTWARE / The software offers an overview from a cabin ventilation system, to each cabin that can be individually adjusted, controlled and monitored via network. Halton's supervision system interface is always built according to customers' needs. CABIN 9214 LON RPU ALARMS Minimum flow Air inlet Overheating Reheater safety switch I/O communication fault Communication fault Terminator LCD Reception Re-heater control 400 W 800 W Temp. control Local Remote Flow control (m3/h) Room supply 250 Flow ref. 300 Flow max. 100 Flow min. Energy saving mode (º C.) Maximum Optimum Minimum History trends Actual Maximum Setpoint Minimum Close ETHERNET ER ILONAC :12 m LCD ECR HVAC Workshop CABINS 17

18 Halton Marine fire dampers for safer seas IMPROVEMENT? UPGRADE YOUR SHIP WITH SMOKE-TIGHT FIRE DAMPERS FDB2 - MOST WIDELY SOLD MARINE FIRE DAMPER IN THE WORLD Safety is the most important factor board ships, where a fire could put people s life in serious risk unless necessary precautions are taken. Therefore, it is essential that the equipment chosen to prevent fire progression in a ventilation ductwork is top-class. Fire and gas dampers are typically installed to prevent the spread of fire, smoke and gas between fire zones. Because smoke and toxic gases can be more dangerous than fire itself, it is important that the fire dampers also prevent smoke from spreading. Halton is the manufacturer supplying smoketight fire dampers. The patented blade structure of Halton's FDB2 fire and gas dampers contains special seals that are effective up to 300 C (572 F) and thermally activated graphite seals that expand when the temperature reaches 150 C (302 F) in the ductwork. The construction of the damper contains a lockable blade structure. In addition, the seal has been forced to expand between the end of the blade and the cleat. These unique safety feature ensures air tightness and low leakage of Halton FDB2 dampers. FDB2 FIRE AND GAS DAMPER / FDB2 fire and gas dampers are always manufactured according to customers' needs. Agile production enables fast delivery times. HVAC solutions for refurbishment projects

19 ARCTIC TEST FDB2 / The damper was tested for over three months in cold conditions (-35 C). The damper operated normally for the full duration of the test. After cold conditions, the fire damper was tested in fire conditions. The temperature in the test chamber was set to 1000 C and the test pressure to 1000 Pa. The test results show that the cold conditions had no affect on the operation of the fire damper. FDB2 IN FIRE CONDITIONS 300 PERFORMANCE OF FDB2 / FDB2 is truly desgined for fire. Tightness of FDB2 improves substantially under fire conditions. Typically, steel deformation during fire increases the damper leakage and allows the smoke and other toxic gases to spread out into the ductwork. 250 Leakage (m 3/h) standard fire and gas damper FDB Minutes (from 20 to 500 C in 5 m inutes) 19

20 Droplet separators IMPROVEMENT? BETTER PROTECTION OF VENTILATION SYSTEMS Droplet separators are used to protect e.g. ventilation systems, air handling units, diesel engines and marine gas turbines. Halton Marine droplet separators are designed for demanding applications, such as marine, oil & gas, chemical, nuclear and paper industries, where the easy installation, high-efficiency and special design of the separators play an important role. Weather conditions will undoubtedly vary, but even in the calmest weather conditions, the air contains salty spray particles. Better filtration efficiency means better protection, which directly results in maintenance, repair and replacement cost savings. Halton Marine offers a selection of highefficiency droplet separators according to the customers' needs that are easy to install, easy to access and can produce savings in life-cycle costs. HVAC solutions for refurbishment projects

21 DROPLET SEPARATORS / Can be tailored according to the customers' needs. The construction of a two-stage droplet separator includes a separator, frame and filter. Net and mask louvre are available as an option. The droplet separator has reached A-Class results. DROPLET SEPARATORS 21

22 Your partner during the entire life cycle of the system DESIGN MAKES A DIFFERENCE Halton Marine offers several options to test and verify different types of air-conditioning solutions. Halton SEAVIEW with two cruise ship cabins and a connecting corridor is a complete HVAC installation with an extensive range of air-conditioning solutions and measurement devices. The installation consists of a fully automatic monitoring system for energy consumption, comfort and safety by continuous measurement. Different types of terminal units, supply and exhaust products are integrated into the cabin architecture. Remote control and monitoring of cabin air-conditioning operates both on a LON or Ethernet network. Halton s world-class measurement laboratories are an ideal place for sound generation, attenuation and air velocity measurements. It is also possible to build a mock-up inside a velocity laboratory to test integration and functionality of different solutions in order to find the most comfortable conditions. If the a customer finds the experiment difficult to set up, Halton Marine offers computational fluid dynamics (CFD) simulation services for optimizing the ventilation system functions. With CFD, it is possible to simulate heat transfer, temperatures, velocities, and to verify comfort in the room. At Halton, CFD simulations can be validated against laboratory measurements. HVAC solutions for refurbishment projects

23 Maintenance services for UV light technology and M.A.R.V.E.L. Spare part service Fast service Product and solution deliveries Installation and commissioning services Testing User training Halton HVAC audit Mock-up installation and verifiication test Design services Recommendations WE ARE AT YOUR SERVICE SERVICES 23

24 Halton Halton Marine, one of the world s leading suppliers of marine HVAC, develops, manufactures and markets reliable, high-quality ventilation solutions specifically designed for marine, navy and offshore applications. Our know-how and expertise will support you at every stage of the build - from the design stage to indoor environment solutions and indoor environment management. Halton Marine Pulttikatu 2 FIN Lahti, Finland Tel (0) Fax +358 (0) haltonmarine@halton.com Halton Group specializes in indoor environment solutions, ranging from public and commercial buildings to foodservice facilities. Founded in Finland in 1969, Halton currently operates in 24 countries around the world, with annual sales of 140 million and over 1100 employees. The company has production facilities in Canada, China, France, Finland, Germany, Hungary, Malaysia, Norway, United Kingdom and USA. Halton Marine s sales offices, distributors and agents are listed at Contacts for refurbishment projects Sami Piirainen (sami.piirainen@halton.com) / Tel (0) / Europe Sean Grigsby (sgrigsby@haltoncompany.com) / Tel / USA

Halton - Achieving Energy Efficiency in School Design

Halton - Achieving Energy Efficiency in School Design Halton - Achieving Energy Efficiency in School Design Enabling Wellbeing Halton Design Tools Drive Energy Efficient Kitchen Ventilation and Comfort Today, nutritional guidelines for school foodservice

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

ENHANCED LABORATORY HVAC SYSTEM

ENHANCED LABORATORY HVAC SYSTEM ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

Glossary of HVAC Terms

Glossary of HVAC Terms Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Knowledge for optimal efficiency

Knowledge for optimal efficiency Engineering Onboard Climate Control Knowledge for optimal efficiency MARINE HVAC-R MARINE HVAC-R ADVANTAGES 2 KNOWLEDGE FOR OPTIMAL EFFICIENCY The BRONSWERK Advantage It s like the ideal day at sea when

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

HVAC Checklist - Long Form

HVAC Checklist - Long Form HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,

More information

HOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN

HOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN HOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN Presented to: ASHRAE YEA Illinois Chapter Specialty Environment Design Conference March 24, 2014 Jean O. Gibbons, PE, LEED AP Senior Vice President Grumman/Butkus

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

More efficiency in schools with HVAC, lighting and security

More efficiency in schools with HVAC, lighting and security The worldwide standard for home and building management More efficiency in schools with HVAC, lighting and security Simply first class: Higher energy efficiency and more flexibility thanks to Synco HVAC

More information

Basics of HVAC Cleaning

Basics of HVAC Cleaning Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project

More information

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB

More information

Hotel System Management The Hotel Smartest Solution

Hotel System Management The Hotel Smartest Solution Hotel System Management The Hotel Smartest Solution Apice Hotel System is a natural evolution of the Building Automation line; it integrates a number of highly technological products, specifically designed

More information

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size

More information

Using Time-of-Day Scheduling To Save Energy

Using Time-of-Day Scheduling To Save Energy The following article was published in ASHRAE Journal, May 29. Copyright 29 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. It is presented for educational purposes only.

More information

NORSOK STANDARD H-001 Rev. 4, Nov. 2001. Heating, ventilation and air-conditioning

NORSOK STANDARD H-001 Rev. 4, Nov. 2001. Heating, ventilation and air-conditioning NORSOK STANDARD H-001 Rev. 4, Nov. 2001 Heating, ventilation and air-conditioning This NORSOK standard is developed by NTS with broad industry participation. Please note that whilst every effort has been

More information

SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION SYSTEM CLEANING

SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION SYSTEM CLEANING SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION PART 1 - GENERAL 1.1 SUMMARY A. Section includes cleaning of interior surfaces of HVAC equipment. The HVAC equipment cleaning work includes the following: 1. Air

More information

air conditioners how to choose a cooling system

air conditioners how to choose a cooling system air conditioners how to choose a cooling system taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home and a reduced

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs

More information

Technical requirements

Technical requirements Technical requirements of site preparation for TF-T1 Module Project Manager / / Head of technical department /K. Nikitin/ St.-Petersburg 2009 Contents 1. Technical specification of TF-T1 module 2. Appearance

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing

More information

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

Radiant Panels and Chilled Sails. www.price-hvac.com

Radiant Panels and Chilled Sails. www.price-hvac.com Radiant Panels and Chilled Sails www.price-hvac.com Radiant Panels and Chilled Sails Introduction Radiant panels use thermal radiation to modify surface temperatures in order to provide sensible cooling

More information

Energy Efficient HVAC-system and Building Design

Energy Efficient HVAC-system and Building Design Energy Efficient HVAC-system and Building Design Maija Virta 1, Harri Itkonen 1, Panu Mustakallio 1, Risto Kosonen 1 1 Halton Oy, Finland Corresponding email: maija.virta@halton.com SUMMARY This paper

More information

HEATING, VENTILATION & AIR CONDITIONING

HEATING, VENTILATION & AIR CONDITIONING HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating

More information

Guide Specification SECTION 23 08 00 - COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY

Guide Specification SECTION 23 08 00 - COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY SECTION 23 08 00 - COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. HVAC Commissioning description. 2. HVAC Commissioning responsibilities. 1.2 REFERENCES A. American Society

More information

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN products > Energy & Cost Saving Products OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration HVAC energy & COST SAVING POSSIBILITIES A

More information

Mistrale. Fusion Terminal

Mistrale. Fusion Terminal Mistrale Fusion Terminal PUBLICATION NATURAL VENT. 1 SEPT 2015 Features - Slimline energy efficient ventilation solution - Standard and high capacity terminals provide 128 or 256 L/s capacity - Compliant

More information

COMMISSIONING OF HVAC SYSTEMS

COMMISSIONING OF HVAC SYSTEMS FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning

More information

- Save lives and reduce material damage

- Save lives and reduce material damage - Save lives and reduce material damage Ultra Fog specialises in high pressure sprinklers for fire extinction using water fog, both at sea and on land. Our base is in Gothenburg, which is where we carry

More information

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers C P I P O W E R M A N A G E M E N T WHITE PAPER Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers By Anderson Hungria Sr. Product Manager of Power, Electronics & Software Published

More information

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS National Air Duct Cleaners Association 1518 K Street, N.W. Suite 503 Washington, DC 20005 (202)

More information

Terms of Reference Air Handling Unit (HVAC System) Cleaning

Terms of Reference Air Handling Unit (HVAC System) Cleaning Terms of Reference Air Handling Unit (HVAC System) Cleaning Introduction General cleaning of the air handling units is currently undertaken by the Mechanical Division staff composing of 3 personnel. Cleaning

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE APPLICATION NOTE TI-138 TSI s IAQ-CALC TM Indoor Air Quality Meter and TH-CALC TM Thermohygrometer calculate Percent Outdoor Air (%OA). In order to take

More information

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Methods for Effective Room Air Distribution Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Agenda Overview LEED issues and Update Perimeter Acoustics Thermal Comfort IAQ / Standard 62.1 Update

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

Room thermostats wide variety and high energy efficiency

Room thermostats wide variety and high energy efficiency Room thermostats wide variety and high energy efficiency New room thermostats of modern design for fan coil units and universal applications Answers for infrastructure. Room thermostats energy-efficient

More information

More efficiency in hotels with HVAC, lighting and security

More efficiency in hotels with HVAC, lighting and security The worldwide standard for home and building control More efficiency in hotels with HVAC, lighting and security Simply comfortable: Higher energy efficiency and more flexibility thanks to Synco HVAC controllers

More information

Scope of Work. See www.sei.ie for resources available

Scope of Work. See www.sei.ie for resources available HVAC SWG Summary Background Pool energy-efficiency knowledge Increase cost-competitiveness Develop resources aimed at assisting in reducing HVAC energy consumption Address barriers to energy-saving HVAC

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS -KESKUSTA One half of Finns live in housing blocks, which is a safe and comfortable way to live. Welcome a board! Buildings and the Finnish climate There

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

More efficiency in office buildings with HVAC, lighting and security

More efficiency in office buildings with HVAC, lighting and security The worldwide standard for home and building control More efficiency in office buildings with HVAC, lighting and security Simply more productive: Higher energy efficiency and more flexibility thanks to

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries. www.lonix.com

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries. www.lonix.com Guest Room Controls & Monitoring System Integrated Solution for Hotels Southern Countries www.lonix.com GUEST ROOM CONTROLS & MONITORING SYSTEM INDEX 1 GENERAL... 3 1.1 SYSTEM INTEGRATION... 3 1.2 USER

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS DATA CENTERS Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS COSTLY FAN ENERGY REDUCED BY CAMFIL PREMIUM PRODUCTS = COST SAVINGS Power Usage Effectiveness (PUE) is an important metric

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

SECTION 15950 - TESTING, ADJUSTING, AND BALANCING

SECTION 15950 - TESTING, ADJUSTING, AND BALANCING SECTION 15950 - TESTING, ADJUSTING, AND BALANCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for

More information

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) 1. In addition to the information scheduled below, the pre-tender designer is responsible for: (i)

More information

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications 1 CO2 Incubator Model CCL-170_-_ CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications Welcome to Esco Esco s Vision is to provide enabling technologies for scientific

More information

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues LBNL-6129E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Liping Wang, Tianzhen Hong Environmental

More information

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok. 44969-09 Sag 09/1437

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok. 44969-09 Sag 09/1437 technical standards Offshore Substation HVAC System ETS-09 Rev. 2 Dok. 44969-09 Sag 09/1437 Revision survey Document title HVAC System Document no. 44972-09 Target group Fabrications Contractors and Designer

More information

Variable Air Volume - VAV

Variable Air Volume - VAV Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:

More information

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat Energy Saving Tips Nowadays when Energy costs are skyrocketing and the awareness to environmental issues is increasing, we all want to reduce energy consumption and have a greener lifestyle. Heating &

More information

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency. www.usa.siemens.

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency. www.usa.siemens. Comprehensive Solutions for Data Centers Rely on Siemens for maximum uptime, reliability, and efficiency. www.usa.siemens.com/datacenters Siemens can meet the demands of your mission critical facility.

More information

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018 USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and

More information

Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency

Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency Because HVAC systems comprise a large amount of a building s operating costs, it makes sense to ensure these systems

More information

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program

More information

Energy Efficiency in Industrial HVAC Systems

Energy Efficiency in Industrial HVAC Systems Energy Efficiency in Industrial HVAC Systems Heating, ventilation and air conditioning (HVAC) constitutes up to 35 percent of energy used in manufacturing facilities. This fact sheet is geared towards

More information

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health Background Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health This document provides guidelines for the design and installation of Class

More information

Fire Protection of Data Centres

Fire Protection of Data Centres Fire Protection of Data Centres With SEM-SAFE High-Pressure Water Mist System Danfoss Semco A/S Total Solution Provider of Certified Fixed Fire Fighting Systems Need a fire fighting system that: Allows

More information

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Content Heating / Ventilation / Air Conditioning 3 The Right Room Climate 4 Optimised Energy Efficiency and well-being Room

More information

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA.

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA. 1. There is verbiage in the hazardous material report referring to a state licensed abatement contractor. Within the recommendations part of the report (page 64 of 111 of the specification pdf) is the

More information

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget A PRIMER Educational HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget Contents: Introduction: The best HVAC system is durable, reliable

More information

HVAC. Kitchen Exhaust. rooftop equipment! let s drop on a few exhaust fans! it doesn t get easier!

HVAC. Kitchen Exhaust. rooftop equipment! let s drop on a few exhaust fans! it doesn t get easier! HVAC & Kitchen Exhaust The Heart of Restaurant HVAC rooftop equipment! let s drop on a few exhaust fans! it doesn t get easier! 1 CKV Design: Just not that easy! There is no piece of equipment in the commercial

More information

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM J.S. Hu, Philip C.W. Kwong, and Christopher Y.H. Chao Department of Mechanical Engineering, The Hong Kong University of Science and Technology Clear Water Bay,

More information

- Save lives and reduce material damage

- Save lives and reduce material damage - Save lives and reduce material damage Small droplets reduce heat to a minimum Ultra Fog s high pressure water fog sprinkler system is based on water being sprayed through special nozzles at high pressure.

More information

Efficient building technology for retirement and nursing homes

Efficient building technology for retirement and nursing homes The worldwide standard for home and building control Efficient building technology for retirement and nursing homes Simply safe: Higher energy efficiency and more flexibility thanks to Synco HVAC controllers

More information

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more FIRE PROTECTION SYSTEMS Fire protection systems, measures and equipment are all related to the safety of the occupants and the protection of the property. As part of a building design and its intended

More information

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715, 4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

Sample - Existing Building Commissioning Plan

Sample - Existing Building Commissioning Plan Sample - Existing Building Commissioning Plan Version: Draft for Review Final Approved: Owner Site Address: Primary Site Contact Name and Telephone Number: Date Building Description The site consists of

More information

Analysis of HVAC Control Strategies

Analysis of HVAC Control Strategies PUBLICATION DATE: Q1 2009 REF NUMBER: HVAC SWGII 006 03 HVAC SPECIAL WORKING GROUP Analysis of HVAC Control Strategies 06 Table of Contents 1 Introduction 2 2 Scope 3 3 Analysis 4 3.1 Strategy 1 4 3.2

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power

More information

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval Take the complication out of cooling Data center cooling equipment and service from Alfa Laval How to make cooling less complicated As data grows, so does the demand for new data centers with increased

More information

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP research journal 2013 / VOL 05.01 www.perkinswill.com SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP ARCHITECTURE AND ENGINEERING OF SUSTAINABLE BUILDINGS Current Trends in Low-Energy HVAC Design

More information

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. LIFE IN PURSUIT OF QUALITY FROM THE VILLAGE FORGE TO A GLOBAL CORPORATION The Directors of AL-KO KOBER SE (from right to left): Stefan Kober (CEO),

More information

Flexibility, Efficiency In San Antonio Arena

Flexibility, Efficiency In San Antonio Arena 2005, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Reprinted by permission from ASHRAE Journal, (Vol. 47, No. 9, September 2005). This article may not

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53% 1 1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53% 2. How much money do commercial facilities spend per square foot on energy costs

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D) Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2013 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Heat

More information

Data Centres A complete solution to noise control and acoustic packages

Data Centres A complete solution to noise control and acoustic packages Data Centres A complete solution to noise control and acoustic packages Introduction World class noise control. Expertise you can trust. IAC Acoustics is world-renowned for providing cost effective solutions

More information

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates Causes of High Relative Humidity Inside Air Conditioned Buildings Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates S. FLORIDA AVE. AMBIENT 91 F db / 78 F wb 16,000 HOURS ANNUALLY THAT wb

More information