1 DATA CENTERS Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS
2 COSTLY FAN ENERGY REDUCED BY CAMFIL PREMIUM PRODUCTS = COST SAVINGS Power Usage Effectiveness (PUE) is an important metric tool that measures and tracks where and how improvements can be made in efficiency performance of the electrical and mechanical infrastructure the lower the ratio, the better the efficiency. A PUE ratio can be dramatically lowered by the reduction of electrical energy draw, or fan energy in the data center s cooling system. The efficiency and energy curves of fans used in the cooling systems is far from constant. There can be a difference of 30% or more between peak and low efficiency in fan working range. Filter pressure drop is the driving force behind fan energy expenditures. If low cost filters are installed, pressure drop will cause the system to lose efficiency, sending fan energy costs soaring, which in turn will show a rise in the PUE ratio. Regardless of the type of cooling or AHU system installed in a facility, to manage pressure drop and maintain as close to peak fan efficiency as possible, it s imperative to evaluate the choice of filters used. When you consider the number of filters needed annually in a system, the guaranteed efficiency and Total Cost of Ownership (TCO) should be the key drivers for determining which filter selection is the best solution. The majority of the energy consuption in your facility is the data center. This chart represents the energy survey of a 21-story office building. It s a fact Data Centers consume an exorbitant amount of energy. With Camfil, data centers have documented six figure savings in total cost of ownership. Camfil s Farr 30/30, Durafil ES 2 and Hi-Flo ES filters have Energy Cost Index (ECI) ratings of five stars the highest performance rating available. Camfil uses a proprietary blend of fine fibers that uses a mechanical particle capture principle which does not require an electret charge. This offers the longest life and lowest average pressure drop while in service over the life of the filter...guaranteed! Low cost, coarse fiber filters, which incorporate an electret charge to operate, can drop in efficiency and increase in pressure drop in a short period of time resulting in increased fan energy consumption and shorter filter life. Although the upfront cost for these filters may be lower, the Total Cost of Ownership (TCO) is higher because they are on the negative side of Life Cycle Cost (LCC) values when compared to the fine fiber media used in Camfil products. Camfil s low average pressure drop filters allow AHUs and fans to be downsized, saving operating costs and capital costs on initial installation. Conversely, if a system isn t optimized at design, Camfil filters can replace substandard filters, or can be retrofitted with FastFrames or Multi-Track hardware for short term payback. These are just some of the factors that are considered in Camfil s LCC Software (see page 3). Camfil offers a free LCC analysis which is performed by our exclusive distributor in your area. Camfil s longer lasting, fine fiber filters extend equipment life and reduce maintenance. Data firms consume energy Camfil has documented significant energy savings for our data center customers, in some cases, by as much as six figures annually. According to DOE statistics, the data center electricity usage of 30 billion kilowatt hours, in 2001, soared to 100 billion kilowatt hours by Analysts project this figure will quadruple over the next three years. Business enablement platforms bear increasing demands for cloud access this drive will push mega data center production to jump eight times from the standards of today by the year FARR 30/30 With its industry leading 5-Star ECI Rating, the Camfil Farr 30/30 sets the standard for medium efficiency air filtration. When used as a prefilter, a stand-alone HVAC filter, or as the main filter in custom data room air conditioning units, the Farr 30/30 will remove nuisance dusts and staining particles, and increase the life of downstream final filters by removing contaminants that shorten the life of final filters. Using a mechanical efficiency to provide MERV 8 and MERV 8-A performance levels, the Farr 30/30 will maintain its efficiency throughout the life of the filter. LCC SOFTWARE The selection of air filters for data processing facilities is a critical decision when considering filter effectiveness in providing a clean environment. An almost equally critical factor is what a filter will cost over its lifetime in the system, or its Total Cost of Ownership (TCO). There are hidden costs to air filters, with energy usage at the top of the scale. This is followed by associated labor to service the filters, disposal costs and carbon footprint. Camfil can predict your TCO using our proprietary Life Cycle Costing (LCC) software. It can also predict the optimum filter change-out point to optimize energy usage and filter life based upon the actual operating parameters of your facility. DURAFIL ES 2 The Durafil ES 2 offers high efficiency particle removal down into the sub-micron particle range to protect the most sensitive semiconductor and electromechanical equipment from contamination. Its glass mat media maintains efficiency throughout the life of the filter and its increased media area ensures maintained low pressure drop and longer filter life. The Durafil ES 2 can save 40% or more in energy expenditures when compared to competitive products. Inputs include operating velocities, filter performance data pulled from a comprehensive information database of competitive filters, energy cost per kwh, number of hours of operation, labor cost projections, disposal costs and information related to total carbon footprint. Your local Camfil representative can run a data center specific LCC analysis at your convenience to see how you can save thousands, even tens of thousands of dollars a year. HI-FLO ES Life Cycle Costing software is a proprietary modeling tool developed by Camfil that allows users to evaluate and optimize air filter selection and change out points to reduce total cost of ownership. The Hi-Flo ES uses a Camfil-exclusive high loft micro fine glass media to capture particles down into the sub-micron particle range to protect data center equipment from contamination. The Hi-Flo ES may be used as the only filter in a single-stage system eliminating pressure drop and service requirements associated with two-stage filtration systems that require a prefilter. Available in MERV 11, MERV 13, MERV 14 and MERV 15, its MERV and relative MERV-A testing values are equivalent ensuring that performance is maintained throughout filter life. 2 Camfil Clean Air Solutions Camfil Clean Air Solutions 3
3 OPTIMIZATION ENERGY SAVINGS Outside Air Intake Plenum Mixing Area Farr 30/30 Fine Fiber And Durafil ES2 Filters Cooling Coils Condensing Coils Fan Arrays Exhaust Air Plenum Supply Air Plenum Misting Coils Supply Air Shaft Misting Eliminator Exhaust Fans & Louvers In most data center applications, Camfil recommends MERV 13 filters for the best balance of particle removal efficiency, low energy expenditures and a long filter life. Depending upon individual facility considerations, common configurations may include the Hi-Flo ES as the only filter stage or a Camfil Farr 30/30 with a Durafil ES 2 for two-stage designs. Data centers have critical cleanliness requirements, which is why Camfil recommended filters also have a MERV-A equivalent to their published MERV this ensures sustained filter performance over the entire life of the filters. Coarse fiber, or synthetic media products, lose efficiency over time often sacrificing filter efficiency resulting in a dirtier environment. Outside Air Louvers & Dampers Return Air Dampers Exhaust Air Ceiling Plenum Server Racks Hot Aisle Containment Panels 5-Star ECI Rating Camfil s filters are rated as 5-Star filters through the Energy Cost Index (ECI) program. Based upon a five-star scale, the Energy Cost Index is an indicator of what a filter will cost over its lifetime. The best rating five stars indicates that the filter is the most energy-efficient, longest lasting filter available. Farr 30/30 Durafil ES 2 Hi-Flo ES No PreFilter Necessary FASTFRAME The Camfil FastFrame for built-up air filter banks does not require cumbersome fasteners or clips to install filters into the frame. It accepts any headered air filter, including pads, pleats, bags, boxes and v-bank filters. It can also be used for two-stage filtration applications. Air bypass is eliminated as the air filters snap into place against a replaceable frame-to-filter seal ensuring less than ½ of 1% leakage across the filter and frame combination all of the air seen by the system will be treated by the system. The FastFrame is available in 24-inch by 24-inch, 12-inch by 24-inch, 20-inch by 24-inch and 20-inch by 20-inch sizes to accommodate a variety of airflow requirements. Existing systems can be retrofitted with Fast Frame or Multi-Track hardware. 4 Camfil Clean Air Solutions Camfil Clean Air Solutions 5
4 ON-SITE TESTING CAMFIL CAMCLEANER The Camfil CamCleaner provides clean air to data center areas that may require a higher level of cleanliness than the rest of the facility. It is also used to supplement HVAC systems that lack clean air performance required to maintain the data center s integrity. CamCleaner is available as a free-standing portable unit, or in a horizontal configuration that suspends within a room or connects to a ducted air distribution system above a ceiling. Available in 2000 or 4000 cfm airflow capacities, the CamCleaner accepts a variety of air filter efficiencies from MERV 8 prefiltration, various configurations and high efficiency final filtration, to HEPA level filtration for removing ISO cleanroom level contaminants. The freestanding portable unit includes carbon filtration capabilities for facilities that may have corrosive gas or odor problem concerns. LEADING THE WAY IN CLEAN AIR TECHNOLOGY The solution is clear protect your best in class technology with ours. Camfil is the global leader in clean air technology and air filtration products. We are the world s largest designer and manufacturer of air filters and related products, with over twenty six manufacturing facilities, six research and development sites, and over sixty five sales offices worldwide. Camfil employs over 60 global engineers and PhDs focused on product development more than all of our competitors combined. This ensures our products deliver performance and cost savings unachievable by other brands. Camfil is the only company with multiple air filter testing labs set to perform ASHRAE guideline air filter tests, and we are the only company with the equipment to perform ASHRAE Appendix J tests. We use this foundation to develop our products with the focus on premium performance. Servicing and supporting a broad spectrum of industries and administrations, Camfil takes pride in the fact that our products are of the highest quality, with the longest life, as well as the lowest operating and maintenance costs. We strive to develop and create products that well exceed industry standards and requirements. Strict monitoring, ISO certified quality control manufacturing processes and frequent product sample testing in our world-class testing facilities ensure that our customers receive industry leading product performance. Camfil is the world s largest designer and manufacturer of air filters with 26 manufacturing facilities around the globe. CAMFIELD LAB CAMTESTER II CamTester II, Camfil s mobile energy auditor with integrated fan, flow controller, and pressure transducer is used to measure filter performance on all styles of HVAC air filters. The remote display measures and shows the set air flow rate, the cubic feet per minute, the air filter s static pressure, and the energy consumption of the integrated fan in watts. 6 Camfil Clean Air Solutions Camfil s CamField Lab sets a higher standard for users to evaluate one air filtration product versus another, at the user s site, under their unique conditions by testing individual air filters either Camfil filters or competitors filters. Air quality managers can evaluate filters for particle size versus efficiency, using instruments that provide particle counts in individual bands that includes micron sizes from 0.3 to 0.5, 0.5 to 0.7, 0.7 to 1.0, 1.0 to 2.0 and 2.0 to 5.0., and can also provide cumulative totals from one selected particle size and larger. Detailed reports help you to attain data that may be critical to analyze factors such as temperature, humidity and airflow histories. Camfil Clean Air Solutions 7
5 CAMFIL is the world s largest and leading manufacturer of filters and clean air solutions. For over 50 years Camfil has been the global leader for air purification solutions. Our mission is clear. We are dedicated to providing exceptionally high quality air filtration for the benefit of human health, commercial processes, and environmental protection. There s a science behind clean air. Our CamField Mobile Lab, In-situ testing and Life Cycle Cost analysis software will help you determine the best performance outcome and the best value for your data center facility. Call your Camfil representative today. For further information please contact your nearest Camfil office.
Quick wins for energy savings in buildings
Quick wins for energy savings in buildings Choosing low energy air filters for both optimized energy performance and indoor air quality Executive Summary HVAC systems heat, cool and clean the air within
More informationDATA CENTRES. Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions
DATA CENTRES Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions Camfil Farr Leading the way in clean air Technology About Camfil Farr Camfil Farr is a world Leader in clean air
More information3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence
3M Purification Inc. 3M Air Management s for Your Commercial HVAC Needs Create an Air of Confidence Pursuing Innovation 3M Company has long encouraged employees to pursue ideas and concepts that might,
More informationA. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
More informationCamfil Farr Technical Services Bulletin
Camfil Farr Technical Services Bulletin ASHRAE Testing for HVAC Air Filtration A Review of Standards 52.1-1992 & 52.2-1999 The American Society of Heating, Refrigeration, and Air Conditioning Engineers
More informationRobert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade
Robert McCabe Director, Health Care Solutions HTS Chicago Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Biography Robert McCabe has been involved in commercial
More informationDealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges
More informationCamfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality
Camfil Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality Most non-practitioners notice the HVAC system when it is too hot, or too cold, or in other ways not working
More informationSECTION 23 01 30.51 HVAC AIR-DISTRIBUTION SYSTEM CLEANING
SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION PART 1 - GENERAL 1.1 SUMMARY A. Section includes cleaning of interior surfaces of HVAC equipment. The HVAC equipment cleaning work includes the following: 1. Air
More informationData Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
More information1/15/2013. HVAC Maintenance Repair or Replace & Planned Replace Initiative. Reduce Operating Costs. Improve Comfort / Process Conditions
HVAC Maintenance Repair or Replace & Planned Replace Initiative Greg DuChane, Retail Vertical Market, Director, TRANE Jack Rehder, Western Territory Manager, TRANE Why Maintain Rooftop Units? Reduce Operating
More informationCooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Lars Strong, P.E., Upsite Technologies, Inc. Kenneth G. Brill, Upsite Technologies, Inc. 505.798.0200
More informationHVAC Air Systems. Recirculation Air System Types
HVAC Air Systems Recirculation Air System Types Summary Recirculation air handler fan energy can account for 10 to 30% of total cleanroom energy use. There are three fundamental recirculation system configurations:
More informationCooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Kenneth G. Brill, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc. 505.798.0200
More informationGreen Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
More informationLaminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
More informationHVAC Design Requirements
Maintenance of HVAC HVAC Design Requirements Air Flow Diagram แบบ Recirculation Air Flow Diagram แบบ Once Through Definition Of Conditions As built At rest In operation air air air Maintenance GMP Requirements
More informationCase Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program
More informationUnified Physical Infrastructure (UPI) Strategies for Thermal Management
Unified Physical Infrastructure (UPI) Strategies for Thermal Management The Importance of Air Sealing Grommets to Improving Smart www.panduit.com WP-04 August 2008 Introduction One of the core issues affecting
More informationG u i d e l. Schools CERTIFICATION EDUCATION TRAINING. Recommended Practice
G u i d e l i n e s Schools Recommended Practice TRAINING EDUCATION CERTIFICATION Publication Information Why NAFA Guidelines? The National Air Filtration Association (NAFA) provides Best Practice Guidelines
More informationAIA Provider: Colorado Green Building Guild Provider Number: 50111120. Speaker: Geoff Overland
AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Office Efficiency: Get Plugged In AIA Course Number: EW10.15.14 Speaker: Geoff Overland Credit(s) earned on completion of this course
More informationUltra-Web High Efficiency Nanofiber Filters
Ultra-Web High Efficiency Nanofiber Filters Longer life, cleaner air, cost savings! The Ultra-Web advantage is cleaner air Nanofibers are scientifically proven to have an advantage in efficiency and pressure
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
More informationTop 10 Energy Efficiency Opportunities
Top 10 Energy Efficiency Opportunities 1 Federal Utility Partnership Working Group San Francisco, 5/22/2013 Siva Sethuraman Customer Energy Solutions PG&E 2 Whole Building A comprehensive, performance-based
More informationMC² Market & Competitive Convergence Air Filters: New Facilities, New Standard
MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard Advances in testing procedures, coupled with greater pressure for better IAQ, leads to a new standard By Ron Wilkinson, P.E.
More informationExtend the Life of Your Data Center By Ian Seaton Global Technology Manager iseaton@chatsworth.com
C P I C O N TA I N M E N T S O L U T I O N S WHITE PAPER Extend the Life of Your Data Center By Ian Seaton Global Technology Manager iseaton@chatsworth.com Published August 2013 800-834-4969 techsupport@chatsworth.com
More informationFree Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the
More informationAir Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT. READ ONLY
Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT. THREE COMFORTABLE SOLUTIONS FOR ONE COMFORTABLE HOME. Platinum Series Air Conditioners American Standard Platinum
More informationData Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore
Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore Introduction Agenda Introduction Overview of Data Centres DC Operational
More informationReducing Data Center Loads for a Large-Scale, Net Zero Office Building
rsed Energy Efficiency & Renewable Energy FEDERAL ENERGY MANAGEMENT PROGRAM Reducing Data Center Loads for a Large-Scale, Net Zero Office Building Energy Efficiency & Renewable Energy Executive summary
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationPRESENTATION BY: MIKE BURT AIR FILTER SOLUTIONS INC. DENVER, COLORADO
PRESENTATION BY: MIKE BURT AIR FILTER SOLUTIONS INC. DENVER, COLORADO INEXPENSIVE RETROFIT DESIGNS FOR ABOVE CEILING UNITS Fan coil units Fan terminal units Single ducted fan powered units Heat pump units
More informationGUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY Public Sector ICT Special Working Group SERVER ROOM ENERGY EFFICIENCY This guide is one of a suite of documents that aims to provide guidance on ICT energy efficiency.
More informationData Centers: How Does It Affect My Building s Energy Use and What Can I Do?
Data Centers: How Does It Affect My Building s Energy Use and What Can I Do? 1 Thank you for attending today s session! Please let us know your name and/or location when you sign in We ask everyone to
More informationDehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
More informationCase Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
More informationRack Hygiene. Data Center White Paper. Executive Summary
Data Center White Paper Rack Hygiene April 14, 2011 Ed Eacueo Data Center Manager Executive Summary This paper describes the concept of Rack Hygiene, which positions the rack as an airflow management device,
More informationWhite Paper: Free Cooling and the Efficiency of your Data Centre
AIT Partnership Group Ltd White Paper: Free Cooling and the Efficiency of your Data Centre Using free cooling methods to increase environmental sustainability and reduce operational cost. Contents 1. Summary...
More informationGreening Commercial Data Centres
Greening Commercial Data Centres Fresh air cooling giving a PUE of 1.2 in a colocation environment Greater efficiency and greater resilience Adjustable Overhead Supply allows variation in rack cooling
More informationDatacenter Efficiency
EXECUTIVE STRATEGY BRIEF Operating highly-efficient datacenters is imperative as more consumers and companies move to a cloud computing environment. With high energy costs and pressure to reduce carbon
More informationG U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice
G U National Air Filtration Association Recommended Practice I D E L I N E Procurement Guideline TRAINING EDUCATION CERTIFICATION HVAC Air Filter Purchasing Specification Guideline 1.0 Purpose To provide
More informationTotal Cost of Ownership Tool from 3M
Commercial HVAC Filters Total Cost of Ownership Tool from 3M Restricted budgets challenge facility owners and operators to seek solutions that help save energy and reduce operating costs, while maintaining
More informationHIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
More informationNADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS National Air Duct Cleaners Association 1518 K Street, N.W. Suite 503 Washington, DC 20005 (202)
More informationDrives and motors. A guide to using variable-speed drives and motors in data centres
Drives motors A guide to using variable-speed drives motors in data centres The power behind the data Private public businesses, from banks to supermarkets, to telecommunications companies internet providers
More informationSAM HOUSTON STATE UNIVERSITY
PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the
More informationMechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw
More informationAisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings
WH I TE PAPE R AisleLok Modular Containment vs. : A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings By Bruce Long, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies,
More informationBasics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
More informationDATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates
More information85 F 80 F 50% 75 F 70 F 73.0/61.8 45 F 10% Figure 1
Feb. 07 INTRODUCTION: Wrap around heat pipes are air-to-air heat exchangers that are installed in the airstream upstream and downstream of a cooling coil to deliberately reduce the Sensible Heat Ratio
More informationHVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.
HVAC Systems and Indoor Air Quality Douglas K. Spratt, M.Sc., P.Eng. The 5 Senses Architecture Electrical Structural Mechanical Hearing Seeing Smelling Feeling Tasting HVAC Systems are Dynamic Heat Gains
More informationIMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT
DATA CENTER RESOURCES WHITE PAPER IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT BY: STEVE HAMBRUCH EXECUTIVE SUMMARY Data centers have experienced explosive growth in the last decade.
More informationSubpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
More informationUNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationAdvanced Filtration Media.
Advanced Filtration Media. Fleetguard Fuel Filters with NanoNet Media. Do you want a fuel filter that... protects your injectors better throughout the filter s service interval? is not affected by water
More informationScrew Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires
More information2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms
Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power
More informationAir Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
More informationGas-Phase Filtration. Advanced Solutions for the Removal of Airborne Particulate and Gaseous Contaminants. Better Air is Our Business
Gas-Phase Filtration Advanced Solutions for the Removal of Airborne Particulate and Gaseous Contaminants Better Air is Our Business Gas-Phase Filtration Industry Leader Our Qualifications AAF International
More informationEnergy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling
Energy Efficient Server Room and Data Centre Cooling Computer Room Evaporative Cooler EcoCooling EcoCooling CREC Computer Room Evaporative Cooler Reduce your cooling costs by over 90% Did you know? An
More informationHEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions
HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom Frequently Asked Questions What is a negative air machine and why do I need one?
More informationOptimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER
Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER Lylette Macdonald, RCDD Legrand Ortronics BICSI Baltimore 2011 Agenda: Discuss passive thermal management at the Rack
More informationAir Conditioners. A cool, comfortable solution to take you to a higher standard of comfort. READ ONLY
Air Conditioners A cool, comfortable solution to take you to a higher standard of comfort. Three comfortable solutions for one comfortable home. Platinum Series Air Conditioners American Standard Platinum
More informationChallenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre
Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre S. Luong 1*, K. Liu 2, James Robey 3 1 Technologies for Sustainable Built Environments, University of Reading,
More informationThere are several types of air cleaning devices available, each designed to remove certain types of pollutants.
Please Note: EPA neither certifies nor recommends particular brands of home air cleaning devices. While some home air cleaning devices may be useful in some circumstances, EPA makes no broad endorsement
More informationHot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.
Business Management Magazine Winter 2008 Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc. Contrary to some beliefs, air is quite
More informationENHANCED LABORATORY HVAC SYSTEM
ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of
More informationUltra-Filter. Compressed Air Filter. DF Series
Ultra-Filter DF Series ié~çáåö=íüé=t~ó=áå=^áê=mìêáñáå~íáçå As one of the world s leading manufacturers of compressed air purification equipment, Donaldson has built a comprehensive engineering, manufacturing,
More informationEnergy Efficiency Opportunities in Federal High Performance Computing Data Centers
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
More informationAPC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
More informationIT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS
IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS SUMMARY As computer manufacturers pack more and more processing power into smaller packages, the challenge of data center
More informationSpecialty Environment Design Mission Critical Facilities
Brian M. Medina PE Associate Brett M. Griffin PE, LEED AP Vice President Environmental Systems Design, Inc. Mission Critical Facilities Specialty Environment Design Mission Critical Facilities March 25,
More informationHow To Improve Energy Efficiency In A Data Center
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
More information1. Certification: Employ an ASCS certified by NADCA on a full-time basis. 2. Supervisor Qualifications: Certified as an ASCS by NADCA.
PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationHow High Temperature Data Centers and Intel Technologies Decrease Operating Costs
Intel Intelligent Management How High Temperature Data Centers and Intel Technologies Decrease Operating Costs and cooling savings through the use of Intel s Platforms and Intelligent Management features
More informationWhat to Know When Considering a Cleanroom. by Simplex Technical Staff
What to Know When Considering a Cleanroom by Simplex Technical Staff What to Know When Considering a Cleanroom by Simplex Technical Staff Does your business plan include the development of an area in your
More informationLeveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency
Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency Because HVAC systems comprise a large amount of a building s operating costs, it makes sense to ensure these systems
More informationHVAC Checklist - Long Form
HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More informationCooling Strategies for IT Wiring Closets and Small Rooms
Cooling Strategies for IT Wiring Closets and Small Rooms By Neil Rasmussen Brian Standley White Paper #68 Executive Summary Cooling for IT wiring closets is rarely planned and typically only implemented
More informationMAC 10. Original & IQ FAMILY OF FAN FILTER UNITS
MAC 10 Original & IQ FAMILY OF FAN FILTER UNITS used in: microelectronics medical device semiconductor disk drive laboratory pharmaceutical markets hospitals clean rooms Table of Contents MAC 10 Original
More information1.2 Refrigerant Equipment. General
Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying heating, ventilation and air conditioning (HVAC) work. These standards are not intended to restrict or
More informationClean air solutions FOOD & BEVERAGE INDUSTRY
Clean air solutions FOOD & BEVERAGE INDUSTRY Food & Beverage HUMAN HEALTH MICROSCOPIC CAUSES... Outdoor air carries 200 to 1,500 bacteria per m 3. So an air handling unit with a capacity of 10,000 m 3
More informationNetApp Data Center Design
NetApp Data Center Design Presentation for SVLG Data Center Efficiency Summit November 5, 2014 Mark Skiff, PE, CEM, CFM Director, IT Data Center Solutions Data Center Design Evolution Capacity Build Cost
More informationBenefits of. Air Flow Management. Data Center
Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment
More informationDOE FEMP First Thursday Seminar. Learner Guide. Core Competency Areas Addressed in the Training. Energy/Sustainability Managers and Facility Managers
DOE FEMP First Thursday Seminar Achieving Energy Efficient Data Centers with New ASHRAE Thermal Guidelines Learner Guide Core Competency Areas Addressed in the Training Energy/Sustainability Managers and
More informationAir Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT.
Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT. THREE COMFORTABLE SOLUTIONS FOR ONE COMFORTABLE HOME. Platinum Series Air Conditioners American Standard Platinum
More informationUsing Portable Spot Air Conditioners in Industrial Applications
Using Portable Spot Air Conditioners in Industrial Applications Cooling People, Processes and Equipment In today s highly competitive manufacturing sector, companies are constantly looking for new ways
More informationAnalysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
More informationCooling Strategies for IT Wiring Closets and Small Rooms
Cooling Strategies for IT Wiring Closets and Small Rooms White Paper 68 Revision 1 by Neil Rasmussen and Brian Standley > Executive summary Cooling for IT wiring closets is rarely planned and typically
More informationAir, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360
Autodesk Revit 2013 Autodesk BIM 360 Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360 Data centers consume approximately 200 terawatt hours of energy
More informationNational Grid Your Partner in Energy Solutions
National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National
More informationNEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
More informationMeasuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
More informationEnergy Management Services
February, 2012 Energy Management Services Data centers & IT environments are often critical to today s businesses, directly affecting operations and profitability. General & Mechanical Services has the
More informationDemand Based Static Pressure Reset Control for Laboratories
LLC Demand Based Static Pressure Reset Control for Laboratories Laboratories are generally the largest users of energy in any facility. Whether in a pharmaceutical research facility, a university or a
More informationResidential Duct Systems for New and Retrofit Homes
Residential Duct Systems for New and Retrofit Homes Why it is important to properly design and install high quality, efficient ducted air systems? The efficiency of air distribution systems has been found
More informationTrane Ductless Systems. Get comfortable with a smart solution. READ ONLY
Trane Ductless Systems Get comfortable with a smart solution. Trane Ductless Systems. A smart solution for efficient comfort, where and when you need it. Trane has a tradition of quality lasting more than
More information