IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world



Similar documents
IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

Data Centre Cooling: Don't Waste Money on the Wrong Solution

IT Cooling Solutions. STULZ AirModulator, AirBooster and AirBooster Pro. Air Flow Management for Data Centres

Precise, Reliable and Innovative Air Conditioning for Information and Communication Technology

STULZ the natural choice. Tel-Air-2 Series. Telecom Line

IT Cooling Solutions. CyberAir 2 Precision Cooling Solutions. Making more efficient use of your resources

STULZ View On DataCenter Cooling

IT Cooling Solutions. Wall-Air Series Displacement Evolution. Telecom-Line

IT Cooling Solutions. Precision Cooling Solutions. Maximum efficiency in data centre air conditioning

Elements of Energy Efficiency in Data Centre Cooling Architecture

State of the Art Energy Efficient Data Centre Air Conditioning

Monitoring. STULZ The natural choice. Around the clock Around the world

Free Cooling for Data Centers

IT Cooling Solutions. The Whole Range of. Data Center Cooling Solutions

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CRAC Precision climate control units for data centres

News in Data Center Cooling

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

- White Paper - Data Centre Cooling. Best Practice

System solution for data centres

Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Direct Fresh Air Free Cooling of Data Centres

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Daikin Altherma Hybrid Heat Pump

AIRAH Presentation April 30 th 2014

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

In Row Cooling Options for High Density IT Applications

60-150kW. For more information on Airedale visit SmartCool kW. > SmartCool.

Chilled Water Precision Air Conditioner For Critical Application

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

york air-conditioning products Residential & VRF News 2015

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

STULZ Water-Side Economizer Solutions

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

RiMatrix S Make easy.

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

Reduce data center PUE using Munters innovative cooling solutions

Innovent LASER Packaged Fresh Air Conditioning Units

Defining Quality. Building Comfort. Precision. Air Conditioning

ROTEX gas hybrid heat pump. A strong team.

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Complete Data Center.

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

Absolute and relative humidity Precise and comfort air-conditioning

AIR DEHUMIDIFYING Condensation drying for industry and trade

Daikin Altherma Hybrid Heat Pump

Cooling kw Heating kw

Daikin Altherma Hybrid Heat Pump

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

DataCenter 2020: first results for energy-optimization at existing data centers

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Data Center. Ultra-Efficient chilled water system optimization. White paper. File No: Date: december 03, 2015 Supersedes: new Date: new

Indirect Evaporative Cooling (IDEC) Unit for Data Centers

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

The Different Types of Air Conditioning Equipment for IT Environments

DUCTED AIR CONDITIONING SOLUTIONS

University of St Andrews. Energy Efficient Data Centre Cooling

Blade Server & Data Room Cooling Specialists

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

Maintenance for Energy Efficiency

Improving Data Center Energy Efficiency Through Environmental Optimization

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Case Study: Guaranteed efficiency through standardised data centres

White Paper #10. Energy Efficiency in Computer Data Centers

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Critical Infrastructure for the World s Leading Data Centers

HVAC Infrastructure Retrofit Solutions

White Paper Rack climate control in data centres

Pioneer in sustainability

Infrastructure & Cities Sector

Refrigeration Compressed Air Dryer Buran Ultrapulse

Hiwall Hiross for Telecom. High Performance Air Conditioning

DTU-52 Series. High-Power Digital TV Transmitter. Features

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Transcription:

IT Cooling Solutions DFC² Direct Free Cooling for Data Centres Energy-efficient, reliable and available around the world

Worldwide Green Engineering with Direct Free Cooling from STULZ Forward thinking and cost-efficient from years of experience The trend is towards densely packed server rooms, which generate ever more computing power over an ever smaller surface area and the resulting power is almost completely converted into heat. Without the use of energy-efficient airconditioning solutions, the running costs of air-conditioning climb dramatically and can exceed the entire purchase cost of the technology in the data centre in just a few years. With every new product development, therefore, our engineers are dedicated to the pursuit of further reducing the running costs of air-conditioning. We have repeatedly led the field of precision air-conditioning for almost 0 years now, and continue to develop new, even more efficient systems. Now and in the future, we are focused on one vision: Mission Energy from STULZ. It pays to have energy efficiency with STULZ air-conditioning systems: The air-conditioning of a Hamburg data centre with a surface area of 800 m and a heat load of 1 MW costs only 34,000.- a year with Direct Free Cooling, as opposed to 96,000.- a year with compressor cooling only. This corresponds to savings of 6,000.- a year. Source: STULZ comparison of system costs, basis for calculation 13 ct/kwh

Energy-saving potential thanks to ambient air With Direct Free Cooling, conditioned ambient air below 18 C is used to keep the data centre cool. This brings huge potential savings, but challenges as well. With this cooling method, a large volume of ambient air enters the rooms, so that extended temperature and humidity tolerances must be permitted. If the ambient temperature rises above 18 C, either an integrated DX system with compressors or a separate chiller assumes the task of cooling the data centre, depending on the air-conditioning solution that is installed. Thanks to our many years of experience with precision airconditioning solutions, we have succeeded in optimising all components for Direct Free Cooling, ensuring compliance with the specifications for data centre temperature tolerances according to ASHRAE TC 9.9 008. In addition, the cooling unit and mixing and filtration box are available in various sizes, so they can be selected precisely to suit your requirements and to achieve optimum energy efficiency. Percentage and number of hours per year of temperatures up to and including 18 C (up to 7 C possible according to ASHRAE TC 9.9 008) Hamburg London Moscow Canberra Madrid Istanbul New York Beijing Johannesburg Annual no. of hours 847 8014 7805 7786 6338 64 5997 5563 4833 below 18 C 1 Percentage 95 % 91 % 89 % 89 % 7 % 71 % 68 % 63 % 55 % 1 Hours per year of temperatures up to and including 18 C Percentage of hours with temperatures up to and including 18 C over the year CyberAir units with Direct Free Cooling and fold-away heat exchanger 3

Two systems and three sizes for flexibility to suit all requirements Room size, noise protection, redundancy every project has requirements of its own. This is why CyberAir with Direct Free Cooling is available in both an air-cooled and a liquid-cooled version. What s more, we have divided the sizes into different units, in order to enlarge the heat exchanger surfaces and enable a standardised, modular construction. 1 1 Louver for circulating air and filter pre-warming 3 Louver for outside air F5 Filter (compact type) 3 4 F7 Filter (compact type) 4 5 Louver for circulating air and return air compressor mode, equipped with G4 filter (compact type) 5 Mixing and filtration box (available in size 1,, and 3). The special filters, placed in the outside air path, remove unwanted particles from the incoming air ensuring that clean filtered air, flows into the Data Center and through the sensitive servers. Bag-type filters are used for sizes and 3, which further reduces air-side pressure losses. 3 1 1 Heat exchanger unit Compressor unit 3 Motors for heat exchanger folding mechanism 4 Fan unit with EC fans 4 CyberAir AMD 110 AU with fold-away heat exchanger 4 The air-cooled version consists of 4 components in the data centre (mixing and filtration box, heat exchanger unit, compressor unit and fan unit). The liquid-cooled CW version consists of 3 components in the data centre (mixing and filtration box, heat exchanger unit and fan unit), plus a chiller outside the data centre.

CyberAir keeping your running costs down Our new CyberAir air-conditioning unit with Direct Free Cooling for medium-sized to large data centres slims down on demand, saving even more energy! This works thanks to a special heat exchanger a new design that we have developed and patented for the CyberAir AMD units. When Direct Free Cooling is used, the heat exchanger automatically folds away to the side. The filtered ambient air can then flow into the void under the raised floor unhampered and without further losses. This brings a further improvement in efficiency. In Direct Free Cooling mode, the heat exchanger moves to the side, enabling the conditioned ambient air to flow unimpeded and without losses into the cavity under the raised floor. This technique brings about a further improvement in energy efficiency. In DX or CW mode, the heat exchanger automatically moves back into position, and air-conditioning continues reliably in compressor mode or with chilled water from the outdoor chiller. CyberAir AMD in Free Cooling mode CyberAir AMD in DX (compressor) mode or CW mode, with chillers In the CyberAir ASD units, both ambient air and return air flows through the heat exchanger in FC, DX or CW mode. The CyberAir AMD units, on the other hand, are equipped with a folding heat exchanger, which automatically folds away in Free Cooling mode, so that no pressure is lost. Advantages High energy efficiency through the direct use of Free Cooling Fold-away heat exchanger in the CyberAir AMD for additional energy efficiency Additional savings opportunities in Mixed and DX mode, thanks to enlarged heat exchanger surfaces and low condensing temperature Excellent system scalability Build as you grow! No hydraulics (pipework, pumps, fittings) Maximum reliability thanks to self-contained, simply constructed air-conditioning systems Drastically lower energy consumption than all conventional systems High-quality materials and perfectly harmonised components Lower capital investment than with conventional Indirect Free Cooling systems 5

Intelligent control matters Without intelligent control, the advantages of Direct Free Cooling and the resulting energy savings are simply not achievable. Our C7000 microprocessor, which we have been using for years for our CyberAir and MiniSpace units and Indoor Data Chillers, also controls the DFC² system. The C7000 microprocessor controls and monitors the entire DFC² system, comprising air-conditioning units, filter and mixing units, humidification systems, heat exchangers, compressors and chillers, and it recognises any opportunity to make use of Direct Free Cooling. All active components in perfect balance Supply air control with return air limitation A settable number of units has to be connected and configured into one zone. All zones are independent from each other and are controlled in accordance to the average values Differential pressure control (raised floor) All three louvers of the mixing and filtration box are controlled from the C7000 (0-10V signal) in dependence of the ambient temperature and the room conditions Humidification control by the controller: in the event of low humidity in the room, a signal is sent to the external ENS humidifier, in the event of excessively high humidity in the room, one unit in the zone is set to compressor (dehumidification) mode. 6

Technical data CyberAir DX with Direct Free Cooling Unit type ASD xxx AU 74 8 88 95 100 110 with fixed heat exchanger Airflow m 3 /h 5,000 5,000 33,000 33,000 35,000 35,000 DX cooling capacity (total) 1) R407C kw 75.3 8. 89.0 95.4 99.4 108.1 DX cooling capacity (sensible) 1) R407C kw 75.3 8. 89.0 95.4 99.4 108.1 Compressor power consumption 1) R407C kw 14.4 16.4 16.4 18.6 18.6.4 DX cooling capacity (total) 1) R410a kw 75.7 8. 88.9 95.9 98.9 110.1 DX cooling capacity (sensible) 1) R410a kw 75.7 8. 88.9 95.9 98.9 110.1 Compressor power consumption 1) R410a kw 14.6 16.6 16.6 18.8 18.8.6 Noise level 3) dba 59.8 59.8 60.5 60.5 59.9 59.9 Fan power consumption in DX mode 4) 5) kw 3.5 3.5 7.6 7.6 5.1 5.1 Fan power consumption in DX mode 4) 6) kw 3.5 3.5 7.6 7.6 5.1 5.1 Fan power consumption in DX mode 4) 7) kw 3.5 3.5 6.3 6.3 4.6 4.6 Fan power consumption in FC mode 4) 5) kw 4. 4. 7.0 7.0 7.9 7.9 Fan power consumption in FC mode 4) 6) kw 4. 4. 7. 7. 8.0 8.0 Fan power consumption in FC mode 4) 7) kw 4.1 4.1 6.4 6.4 5.7 5.7 Unit type AMD xxx AU 74 8 88 95 100 110 with fold-away heat exchanger Airflow m 3 /h 5,000 5,000 33,000 33,000 37,000 37,000 DX cooling capacity (total) 1) R407C kw 75.3 8. 89.0 95.4 100.8 109.4 DX cooling capacity (sensible) 1) R407C kw 75.3 8. 89.0 95.4 100.8 109.4 Compressor power consumption 1) R407C kw 14.4 16.4 16.4 18.6 18.6.4 DX cooling capacity (total) 1) R410a kw 75.7 8. 88.9 95.9 100.3 111.5 DX cooling capacity (sensible) 1) R410a kw 75.7 8. 88.9 95.9 100.3 111.5 Compressor power consumption 1) R410a kw 14.6 16.6 16.6 18.8 19.0.6 Noise level 3) dba 58.1 58.1 59.4 59.4 59.3 59.3 Fan power consumption in DX mode 4) 5) kw 3.5 3.5 7.6 7.6 6.0 6.0 Fan power consumption in DX mode 4) 6) kw 3.5 3.5 7.6 7.6 6.0 6.0 Fan power consumption in DX mode 4) 7) kw 3.5 3.5 6.3 6.3 5.5 5.5 Fan power consumption in FC mode 4) 5) kw 3.3 3.3 5.8 5.8 7.7 7.7 Fan power consumption in FC mode 4) 6) kw 3.3 3.3 6.0 6.0 7.8 7.8 Fan power consumption in FC mode 4) 7) kw 3. 3. 5.3 5.3 5.3 5.3 Number of fans 3 Width mm,710 3,110 3,460 Height mm,495 Depth mm 890 Mixing and filtration box Width mm 1,930,330,660 (Size 1) Height x depth mm.000 x 1.980 (Size 1) Filter class pre filter, main filter compact type F5, compact type F7, compact type G4 (Size ) Height x depth mm 3.000 x 1.980 (Size ) Filter class pre filter, main filter bag type F5, bag type F7, bag type G4 (Size 3) Height x depth mm 3.840 x 1.980 (Size 3) Filter class pre filter, main filter bag type F5, bag type F7, bag type G4 Remarks: All data apply at 400V / 3 ph / 50 Hz with 0 Pa ESP 1) Return air conditions: 7 C / 30 % r. h.; condensing temperature: 45 C ) Return air conditions: 7 C / 30 % r. h.; water: 10 / 15 C, 0 % glycol 3) Noise level of unit (without mixing and filtration box) at m distance under free-field conditions 4) The electric power consumption of the fans must be added to the room load 5) Values apply to unit incl. size 1 mixing and filtration box 6) Values apply to unit incl. size mixing and filtration box 7) Values apply to unit incl. size 3 mixing and filtration box 7

Technical data CyberAir CW with Direct Free Cooling Unit type ASD xxx CWU 1300 1600 000 with fixed heat exchanger Airflow m 3 /h 4,000 33,000 34,000 CW cooling capacity (total) ) kw 107.7 145.7 150.3 CW cooling capacity (sensible) ) kw 107.7 145.7 150.3 Noise level 3) dba 58. 57.4 58.5 Fan power consumption in CW mode 4) 5) kw 3.7 6.8 5. Fan power consumption in CW mode 4) 6) kw 3.7 6.8 5. Fan power consumption in CW mode 4) 7) kw 3.7 5.6 4.7 Fan power consumption in FC mode 4) 5) kw 4.3 6. 7.9 Fan power consumption in FC mode 4) 6) kw 4.3 6.4 8.0 Fan power consumption in FC mode 4) 7) kw 4. 5.6 5.7 Unit type AMD xxx CWU 1300 1600 000 with fold-away heat exchanger Airflow m 3 /h 4,000 33,000 35,000 CW cooling capacity (total) ) kw 107.7 145.7 153.9 CW cooling capacity (sensible) ) kw 107.7 145.7 153.9 Noise level 3) dba 56.5 55.7 57.4 Fan power consumption in CW mode 4) 5) kw 3.7 6.8 5.7 Fan power consumption in CW mode 4) 6) kw 3.7 6.8 5.7 Fan power consumption in CW mode 4) 7) kw 3.7 5.6 5. Fan power consumption in FC mode 4) 5) kw 3.5 5.0 7.1 Fan power consumption in FC mode 4) 6) kw 3.5 5. 7. Fan power consumption in FC mode 4) 7) kw 3.4 4.5 5.0 Number of fans 3 Width mm,150,550,900 Height mm,495 Depth mm 890 Mixing and filtration box Width mm 1,930,330,660 (Size 1) Height x depth mm,000 x 1,980 (Size 1) Filter class pre filter, main filter compact type F5, compact type F7, compact type G4 (Size ) Height x depth mm 3,000 x 1,980 (Size ) Filter class pre filter, main filter bag type F5, bag type F7, bag type G4 (Size 3) Height x depth mm 3,840 x 1,980 (Size 3) Filter class pre filter, main filter bag type F5, bag type F7, bag type G4 Remarks: All data apply at 400V / 3 ph / 50 Hz with 0 Pa ESP 1) Return air conditions: 7 C / 30 % r. h.; condensing temperature: 45 C ) Return air conditions: 7 C / 30 % r. h.; water: 10 / 15 C, 0 % glycol 3) Noise level of unit (without mixing and filtration box) at m distance under free-field conditions 4) The electric power consumption of the fans must be added to the room load 5) Values apply to unit incl. size 1 mixing and filtration box 6) Values apply to unit incl. size mixing and filtration box 7) Values apply to unit incl. size 3 mixing and filtration box 8

That's how much energy efficiency and reliability are behind DFC Direct Free Cooling

STULZ Company Headquarters D STULZ GmbH Holsteiner Chaussee 83. 457 Hamburg Tel.: +49(40)55 85-0. Fax: +49(40)55 85 35. products@stulz.de STULZ Subsidiaries AUS CN E STULZ AUSTRALIA PTY. LTD. 34 Bearing Road. Seven Hills NSW 1 47 Tel.: +61()96 74 47 00. Fax: +61()96 74 67. sales@stulz.com.au STULZ AIR TECHNOLOGY AND SERVICES SHANGHAI CO., LTD. No. 999 Shen Fu Road, Min Hang District. Shanghai 01108. P.R. China Tel.: +86(1)54 83 0 70. Fax: +86(1)54 83 0 71. info@stulz.cn STULZ ESPAÑA S.A. Avenida de los Castillos 1034. 8918 Leganés (Madrid) Tel.: +34(91)517 83 0. Fax: +34(91)517 83 1. info@stulz.es F STULZ FRANCE S. A. R. L. 107, Chemin de Ronde. 7890 Croissy-sur-Seine Tel.: +33(1)34 80 47 70. Fax: +33(1)34 80 47 79. info@stulz.fr GB I IN STULZ U. K. LTD. First Quarter. Blenheim Rd.. Epsom. Surrey KT 19 9 QN Tel.: +44(137)74 96 66. Fax: +44(137)73 94 44. sales@stulz.co.uk STULZ S.P.A. Via Torricelli, 3. 37067 Valeggio sul Mincio (VR) Tel.: +39(045)633 16 00. Fax: +39(045)633 16 35. info@stulz.it STULZ-CHSPL (INDIA) PVT. LTD. 006, Jagruti Industrial Estate. Mogul Lane, Mahim. Mumbai - 400 016 Tel.: +91()56 66 94 46. Fax: +91()56 66 94 48. info@stulz.in NL STULZ GROEP B. V. Postbus 75. 1180 AB Amstelveen Tel.: +31(0)54 51 111. Fax: +31(0)64 58 764. stulz@stulz.nl NZ PL USA ZA STULZ NEW ZEALAND LTD. Office 71, 300 Richmond Rd.. Grey Lynn. Auckland Tel.: +64(9)360 3 3. Fax: +64(9)360 1 80. sales@stulz.co.nz STULZ POLSKA SP. Z O.O. Budynek Mistral. Al. Jerozolimskie 16. 0 34 Warszawa Tel.: +48()883 30 80. Fax: +48()84 6 78. info@stulz.pl STULZ AIR TECHNOLOGY SYSTEMS (SATS), INC. 157 Tilco Drive. Frederick, MD 1704 Tel.: +1(301)60 0 33. Fax: +1(301)66 54 87. info@stulz-ats.com STULZ SOUTH AFRICA PTY. LTD. P.O.Box 15687. Lambton 1414. Gauteng Tel.: +7(11)873 68 06. Fax: +7(11)873 31 36. aftersales@stulz.co.za Technical data subject to changes without notice. 1000369 01-11 en STULZ GmbH, Hamburg IT Cooling Solutions Close to you all over the world.... With specialist, competent partners in our subsidiaries and exclusive sales and service partners around the world. Our five production sites are in Europe, North America and Asia. www.stulz.com