RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE



Similar documents
Power & Environmental Monitoring

Packet Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution

Comprehensive Data Center Energy Management Solutions

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

Comprehensive Data Center Energy Management Solutions

Energy Management Solutions

CenterMind P+ Solution for efficient power management

Intelligent Power Distribution in the Data Center

Power Distribution Considerations for Data Center Racks

DATA CENTER PHYSICAL INFRASTRUCTURE

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Eaton epdu. Intelligent and flexible power distribution

Case study: End-to-end data centre infrastructure management

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

Revolutionizing Data Center Infrastructure Management

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

Technologies for Data Centres

PE6108/PE6208/PE8108/PE8208

Improve competiveness of IDC and enterprise data centers with DCIM

Data Center Power Distribution and Capacity Planning:

About Geist. geistglobal.com

Server Technology, Inc.

PN5212/PN5320/PN7212/PN7320

5 Reasons. Environment Sensors are used in all Modern Data Centers

scalable data centre energy management solution

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

MAXIMIZING YOUR DATA CENTER INFRASTRUCTURE: CENTRALIZED MANAGEMENT AND WIRE-FREE ENVIRONMENTAL MONITORING

How To Power A Bladecenter H Servers

Management and Wireless in the Data Center

Power Management. Raritan Description.

Rack Power Distribution

Includes customer case study. February 28, 2013

CenterMind P+ Intelligent Power Management for your Data Center

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Cisco Nexus 7000 Series Power Supply Modules

CenterMind G+ Smart and Proactive Environment Monitoring

One unbelievable solution for rack-level data center power management. Sentry Power Manager. Solutions for the Data Center Equipment Cabinet

How To Use Rittal'S Rizone

Rack Power Distribution. Worldwide

PX Intelligent Rack PDUs

Panduit Infrastructure Management Software for Data Centers and Enterprises

Server Technology, Inc.

Data Center Infrastructure Management (DCIM) Demystified

PatchView+ Generation. The Next. Intelligent Infrastructure Management Solution

Best Practices for Wire-free Environmental Monitoring in the Data Center

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Integrated Wire-Free Solution for Monitoring Power and Environment with RF Code and Sentry Power Manager (SPM)

DATA CENTER SOLUTIONS

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

Data Center Infrastructure Management: How to Optimize Data Center Operations

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers

ICT and the Green Data Centre

The Trellis Dynamic Infrastructure Optimization Platform

Zen Internet Case Study

EO and Smart Federal Government Data Center Management

Preparing for Your First DCIM System Deployment: Auto-Discovery and Data Collection

PE8216/PE8324. Energy Intelligence Solutions

Application Briefs: Remote Office Environment

Environmental Data Center Management and Monitoring

Distributing Power to Blade Servers

Mejora la Eficiencia Operativa en Centros de Datos

Case Study Nottingham Trent University

Data Centre Infrastructure Assessment

Classification of Data Center Infrastructure Management (DCIM) Tools

Foreseer Services. Product application guide. Table of contents

Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM)

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

Applying Data Center Infrastructure Management in Collocation Data Centers

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Increase the efficiency of power distribution in your high-density data center

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Managing Cooling Capacity & Redundancy In Data Centers Today

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

Re Engineering to a "Green" Data Center, with Measurable ROI

The necessary convergence of IT and Facilities

Modular Datacenter based in a 20' container

Automating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

MAJORSINE Power Inverter

Data Center Infrastructure Management: ERP for the Data Center Manager

Managing the Data Center One Rack at a Time

QuickSpecs. HP 480/277 Volt Solutions. Overview

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Transcription:

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE Highly efficient solutions for power distribution, management and monitoring POWER DISTRIBUTION WIRE-FREE MONITORING LEAK DETECTION

Daxten provides comprehensive power solutions to optimise resources, energy usage and efficiency in your data centre while ensuring reliable and flexible power supply at room, rack and IT equipment level. Furthermore, we provide you with innovative and field-proven tools for monitoring power. By using these tools, you have access to all power parameters, energy consumption readings and PUE reports in real-time and at your fingertips. In addition to power monitoring, environmental monitoring adds temperature, humidity, air pressure, airflow and many more data sets to your data centre overview. To control, manage and visualise all the power and environmental assets and data, we also offer DCIM solutions that give you an overview of your data centre at a glance. 1. Best Practice: Power Distribution via Track Busbar Maximum availability, flexibility and reliability for the electrification of server cabinets In mission critical DC environments the reliability and availability of the productive IT hardware are the pillars of success. Modular, scalable and redundant power distribution is essential to achieve TIER I to IV classification. STARLINE track busway provides reliable 100, 225, 250, 400 and 800 amp busbar that can be installed overhead or under the raised floor. Mounting power tap offs takes only a few seconds by inserting the twist-and-lock plug into the busbar and rotating it 90 degrees at any location along the track. Power cables can then be connected directly to the tap offs allowing for immediate power to new racks. Wire-free power monitoring for individual servers, tap-off or busbar level is available from Packet Power. STARLINE TRACK BUSWAY HIGHLIGHTS:» Modular continuous access track busbar system» Up to 800 Amps and 415 Volts» No cabling required» Easily reconfigurable» Lower TCO than traditional PDU and cable solutions STARLINE TAP-OFF HIGHLIGHTS:» Tap-Offs with 16, 32, 63 Amps» Customised versions upon request» Easy installation via twist-and-lock connector» Rack connections via drop cord or receptacles» Integrated circuit breakers for all power designs 2 Daxten Best Practices for Power & Monitoring

2. Best Practice: Cabinet Power with intelligent PDUs Reliable power supply for servers and network components at rack level To power and monitor active hardware in data centre cabinets we offer ipdus (intelligent PDUs) with outlet monitoring, various levels of security and fuse protection features. Depending on the model, the ipdus are accessible via the serial port, TCP/IP, web browser or wirelessly and integrate power and monitoring functions. Together with vendor specific management applications or third party DCIM or BMS systems, there are limitless ways to manage, monitor and control power in the data centre. We partner with market leader PDU manufacturers Dataprobe, Geist, Raritan and Server Technology, to offer the best solution for your needs. PDU HIGHLIGHTS (MANUFACTURER AND MODEL DEPENDENT):» PDUs available with 8, 16, and 32 Amps (further options upon request)» Single or three phase options 1, 4, 8, 16, 24 or more power outlets» Integrated power monitoring capabilities» Threshold settings, SNMP traps and alerts» Remote power off/on» Sensor ports for environmental monitoring» Support for third-party DCIM and BMS tools Option: On-demand custom PDUs Custom designed PDUs that meet your exact day to day power needs In the case of customers having special requirements for their PDUs, customisation is a very good option to get a product that fits perfectly into their individual IT or DC environment. The choice is up to the customer, e.g. how many outlets, which voltage, amperage, type of circuit breaker, power and environmental monitoring capabilities and/or colours are required. CUSTOM DESIGNED PDU HIGHLIGHTS:» Choice of number of power outlets» Available as single or three phase versions» Available with 8, 16, 32 or 63 Amps» Optional: power and environmental monitoring capabilities» Different colours available» Mounting options: horizontal (requires U space) or vertical (0U)» Optional: zlock Dual IEC Locking Cable Best Practices for Power & Monitoring Daxten 3

3. Best Practice: Secure Power to Device Connections Prevention of downtime with dual sided IEC locking power cables The zlock dual sided locking cables simply replace existing power cables. All connected IT devices are well protected against accidental and vibration disconnects and the resulting power supply disruptions, downtime and equipment damage. ZLOCK DUAL LOCKING POWER CABLE HIGHLIGHTS:» Unique power cable that locks both ends» Locks automatically (C13) and via twist lock (C14)» Requires no vendor specific mating plug or receptacle» Prevents power cables from being dislodged» Increases the reliability of power distribution» Available in C13 to C14, C15 to C14 and C19 to C20» Choice of different colours and lengths The zlock power cords are also available as versions with a single sided locking mechanism. 4. Best Practice: Redundancy for Single Power Devices Micro Automatic Transfer Switches add fail-safe power to any IT component Reliable power for network devices and servers is a vital part in ensuring uptime in any data centre. For IT equipment with single power supplies, the micro ATS is essential in creating redundancy by providing power from two different sources. Without transfer switches, any power interruption can cause failures and downtime. Not only does the μats test the power supply, but also the incoming voltage. If incoming power is interrupted or if over or under voltage is detected, the source is switched from A to B preventing failures and keeping the IT equipment up and running. A and B power sources do not need to be synchronised and switch well within CBEMA curve recommendations. MICRO AUTOMATIC TRANSFER SWITCHES HIGHLIGHTS:» 1, 2 or 3 port versions» Requires 0U rack space» Supports 8 Amps for 208 to 240 Volts» Switches from power feed A to B within 9 and 11ms» Phases do not need to be aligned» Protects against over and under voltage» Virtual circuit breaker with audio alarm 4 Daxten Best Practices for Power & Monitoring

5. Best Practice: Capacity Expansion via Micro DCs Smallest and most cost-effective form factor for on demand DC expansion Mobile and modular Micro Data Centres (MDC) from Elliptical Mobile Solutions are self-enclosed, rack based data centres with up to 42U space for integrating any type of IT equipment. Depending on the MDC model, a closed air or water cooling loop and optional free cooling capabilities are available. As the MDC form factor is smaller than containerised data centres, capacity can be extended only when needed and located in areas that cannot be converted into a full server room. This leads to dramatic cost-savings and faster installation time. EMS MICRO DATA CENTRES HIGHLIGHTS:» Closed cooling loop for IT loads (up to 2.5, 6, 12, 20 or 80 kw)» NEMA 4 (IP56) or NEMA 12 (IP52) protection» Mobile or rack-based enclosure» Easy to deploy, setup and relocate» Shock and vibration isolation protects equipment from damage» Versions for indoor and outdoor usage available» Optional upgrades depending on model 6. Best Practice: Monitor Areas Susceptible to Leaks Leak Detection prevents water damage with catastrophic results in data centres Water leaks pose a huge potential danger in data centres and are one of the main causes of long-term failures of devices and systems. They can also cause technical and structure damage that can be very expensive to fix. Before the threat of even the smallest leak becomes acute and leads to serious risks, the leak first has to be pinpointed and remedied. A SeaHawk leak detection solution represents an effective way of handling this problem. SEAHAWK LEAK DETECTION HIGHLIGHTS:» Reliable detection of water leaks or other liquids» Alerts by SNMP or email depending on model» Spot detectors to monitor a confined zone» Sensing cables to monitor areas susceptible to leaks» Zone controllers generate alarms» Remote controllers pinpoint the exact location of leaks» Controller can be integrated into DCIM or BMS» Communication via SNMP, Modbus, BACnet or N2 Best Practices for Power & Monitoring Daxten 5

7. Best Practice: Centralised Power & Environmental Monitoring Increase resource utilisation, reliability and improve efficiency though monitoring For data centre and facility managers it is essential to ensure the most efficient usage of existing power and cooling capacities. To achieve optimal utilisation, regular monitoring of power and environmental parameters is critical. Monitoring data allows you to identify, analyse and resolve energy, thermal and reliability weaknesses while increasing the PUE in your data centre. Our comprehensive monitoring solutions enable you to centrally control and manage several hundred environmental sensors (e.g. for temperature, humidity, dew point and airflow) and energy parameters like Volts, Amperes, kw, kwh, kva, phase angle and total current for any cabinet, PDU or single IT device. All data points are accessible via serial, TCP/IP, wireless connection or via remote software. PACKET POWER WIRE-FREE-MONITORING HIGHLIGHTS: SMART POWER CABLES» Easily attaches to IT equipment, PDUs and busway plug-ins» Support for IEC, NEMA, Hubbell, Russell Stoll and other connectors» 1 or 3 phases with 120 and 208-240 Volts for 10 up to 100 A» Data collection: V, A, W, power consumption, power factor and peak» Compatible with GUIs from different vendors» Wireless communications designed for data centres» Options for integration into busway plug-ins and other devices ENVIRONMENTAL MONITOR» Easily collect temperature and humidity data» Supports hundreds of measurement points» Wireless data transfer to SNMP or Modbus gateway» Real-time comparison of set point and actual values» Detects different temperature zones at rack level GATEWAY» Data consolidation for up to 300 monitoring units per gateway» Wireless-to-SNMP or Modbus Gateway» Transfers power and environmental data to DCIM solutions» Complete monitoring with only 2 IP addresses EMX ENERGY PORTAL» Management tool for all wire-free monitoring units» Manages thousands of monitoring points» Captures, analyses and reports power and environmental data» Displays power values, temperature, humidity and differential pressure» Dynamic charts and diagrams show power and environmental values» Trend reports on power use, electricity costs and CO2 emissions» Access via (local) software, web and/or cloud service 6 Daxten Best Practices for Power & Monitoring

8. Best Practice: DCIM Management, Monitoring & Visualisation Complete asset, load and capacity management for data centres Data Centre Infrastructure Management solutions give you the graphical overview of your complete data centre infrastructure including power, cooling, asset and space capacity. You can proactively monitor and manage power and environmental conditions at the facility, server room, rack and single device level. In addition, components such as UPS, CRAC units, chillers and other DC equipment can also be included. Real-time status or trend reports for energy consumption, power usage effectiveness (PUE) and environmental parameters are clearly displayed in your customisable DCIM system. The DCIM solutions support SNMP, TCP/ IP, Modbus, BACnet, I /O, obix and Niagara protocols to name a few. DCIM SOLUTION HIGHLIGHTS:» Visualisation and asset management of the complete infrastructure» Capacity management through power and environmental monitoring» Real-time and trend reports for the load, power consumption and PUE» Thermal views at rack levels» Alert management and notifications» Multi-user and multi-location integration» Supports BMS and NMS systems Daxten has been an official endorser of the EU Code of Conduct for Data Centre Efficiency since 2009. Best Practices for Power & Monitoring Daxten 7

» Zonit & Daxten Daxten Ltd Bay 21 Free Zone West Shannon, County Clare» Fujitsu & Daxten IRELAND Tel: +353 (0)61 23 4000 Fax: +353 (0)61 23 4099 info.ie@daxten.com www.daxten.com/ie/» Packet Power & Daxten Daxten Ltd 5 Manhattan Business Park, Westgate London W5 1UP UNITED KINGDOM» Zonit & Daxten Tel: +44 (0)20 8991 6200 Fax: +44 (0)20 8991 6299 info.uk@daxten.com www.daxten.com/uk/ Daxten and the Daxten logo are registered trademarks of Daxten Industries. All other marks are property of their respective owners. Copyright 2015. Daxten Industries. All rights reserved. Daxten UKPM data sheet - version 201505. Subject to change without notice.