Managing the Data Center One Rack at a Time
|
|
|
- Miles Stanley
- 10 years ago
- Views:
Transcription
1 Managing the Data Center One Rack at a Time No Limits Software White Paper #6 By David Cole 2013 No Limits Software. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted, or stored in any retrieval system of any nature without the written permission of the copyright holder.
2 Table of Contents Overview... 3 Why Manage at the Rack Level?... 3 How Does Rack Density Affect Capacity Planning?... 4 Measuring at the Rack Level... 6 Inventory at the Rack Level... 8 Using RFID to Track Assets within the Rack... 9 Using Tethered Solutions to Track Assets within the Rack The Rack Just Got a Lot Smarter Summary About No Limits Software Works Cited No Limits Software 2
3 Simplify data center management by breaking a complex environment into more manageable pieces the racks. Overview The typical data center is an ever-changing system consisting of thousands of IT and infrastructure assets with very complex relationships between the three primary resources: space, power, and cooling. There are a wide range of tools available for data center management. These tools can assist the data center manager in areas such as asset management, real-time monitoring, capacity planning, and process management. In spite of this, data center management remains a daunting task. Why is this? Is it the sheer number of assets? Is it the difficulty in trying to juggle power and cooling resources in a non-homogeneous environment in which 2 kw racks must peacefully coexist with 20 kw racks? Is there a way to make data center management easier? When faced with a complex problem, it is often beneficial to break the problem down into smaller segments. One method to address data center management is to break the large, complex environment (the data center) into more manageable segments the racks. By breaking it down to the rack level, overall data center management is simplified and the resource requirements of IT assets are more closely administered. This white paper addresses the rationale for managing at the rack level and discusses the concept of a rack as an intelligent device rather than simply a housing unit for IT equipment. Why Manage at the Rack Level? In the APC White Paper Power and Cooling Capacity Management for Data Centers (Rasmussen, 2011), Neil Rasmussen explains the reasoning for management at the rack level, saying Accurate answers to questions about changes to the IT infrastructure require information at the rack level. While having power and cooling supply and demand information at the room or facility level helps, it does not provide sufficiently detailed information to answer the questions about specific IT equipment deployments. An effective and practical level at which to measure and budget power and cooling capacity is at the rack level. David Chernicoff echoes this opinion in his white paper The Shortcut Guide to Data Center Energy Efficiency (Chernicoff, 2011): Information about power and cooling at the data center/room level can be useful in answering general capacity questions. However, for accurate answers to questions about changes to the IT infrastructure, it is necessary to have information at the rack level. Having detailed information about power and cooling at the rack level provides the best, and most useful, information for capacity management. With dramatic growth in power consumption at the rack, measuring and managing power and cooling at the rack level becomes increasingly important in the overall management of data center capacity. No Limits Software 3
4 Rack Power Consumption (kw) How Does Rack Density Affect Capacity Planning? Data center capacity planning has typically been done at the data center level, where management makes decisions on the total power, cooling, and space resources needed to support the IT load. This planning often relies on the concept of power density. Unfortunately, the term power density is inconsistent (Rasmussen, Guidelines for Specification of Data Center Power Density, 2005), and includes definitions such as the following: Power consumption of IT equipment / Area used by racks Power consumption of IT equipment / Area used by racks and their clearances Power consumption of IT equipment / Data center space Power consumption of IT, power and cooling equipment / Data center space Power consumption / Number of racks Managing capacity based on the average rack power can result in stranded capacity and increased risk of shutdown due to insufficient resources. The first four definitions are measured in watts/ft 2 or watts/m 2. The final definition is measured in kw/rack. In a homogeneous data center environment, where each of the racks has the same approximate power consumption, any of these definitions can be used for capacity planning as long as the definition is consistently applied. Unfortunately, racks can vary significantly in power consumption, from a patch panel rack drawing 0 kw to blade server racks drawing 20 kw or more. Let s look at a data center with 50 racks and a total power consumption of 300 kw. The average power consumption per rack is calculated by dividing the total power consumption by the number of racks. In this case, Average Power/Rack = 300 kw/50 racks = 6 kw/rack If the data center is designed to support 6 kw per rack, the following figure illustrates the issues which can arise: 25 Rack Density Varies Widely in a Data Center Average Power/Rack 0 Stranded power and cooling due to racks being over-provisioned Shutdown risk due to insufficient power or cooling No Limits Software 4
5 Managing to the average rack power consumption can cause two types of problems. First, there is the issue of stranded resources. If the rack is only consuming 1 kw of power but is being supplied as though it is consuming 6 kw of power, excessive power and cooling are being supplied but not used. This over-provisioning means power and cooling are being stranded and the end result is a decrease in overall energy efficiency. It is important to understand that energy efficiency decreases for data center equipment with lower usage. This graph shows the efficiency of a UPS based on the load. A UPS loaded at 60% operates more efficiently than the same UPS loaded to only 20%. The same holds true for CRAC units, server power supplies, and so on. High Performance Buildings: Data Center Uninterruptible Power Supplies Berkeley Labs (Ton & Fortenbury, 2005) Over-provisioning will always have the impact of lowering the load on the equipment and thereby reducing the overall energy efficiency. Having sufficient power and cooling at the data center level does not mean there is sufficient power and cooling at the rack level. The second, and potentially more serious, issue of managing to the average rack power consumption is the increased risk of shutdown due to insufficient resources. Having sufficient power and cooling at the data center level does not prevent downtime at the rack level. Power generates heat, and increasing the power consumption increases the heat generation, often creating hot spots within the data center. There are many ways to address hot spots including adding additional cooling, in-row cooling, segregating the data center into zones of varying densities, cold or hot aisle containment, and so on, but all require information at the rack level. Without the rack-level knowledge of power and cooling requirements, the data center manager can t make informed decisions as to where to place servers in a rack, which racks to put into a zone, which racks could benefit from cold or hot aisle containment, which rows need additional in-row cooling, and so on. In order to properly address capacity at a rack level, data must be available at the rack level, in particular power and environmental measurements. No Limits Software 5
6 Measuring at the Rack Level Once the decision is made to measure data at the rack level, the next logical question is what should be measured. There are several key data areas to consider: Power o o o How much total power is the rack consuming? How much power is each rack PDU providing? How much power is each IT device consuming? Environmental Sensors o What is the inlet temperature at the front of the rack? o What is the outlet temperature at the back of the rack? o What is the humidity of the air being supplied to the IT equipment? o What is the pressure differential between the hot and cold aisles? Security o Are the front and rear rack doors open? o Are the front and rear rack doors locked? How will the information be used? is the key question when determining what data to collect and how often it should be collected. Not all of this data needs to be collected, of course. With most measurement considerations, the key question is how will the information be used? Is the data going to be used for alerting or for viewing data trends for capacity planning purposes? If the data is to be used for capacity planning purposes and the goal is to view changes over a longer period of time (say months or longer), collecting snapshot data once every hour may be sufficient. If the data is to be analyzed over a shorter period of time, say over the course of a day, snapshots should be collected more often, perhaps once every 5 minutes. If the data is to be used for alerting, however, the devices will have to be polled even more frequently or the devices will have to provide some means to push the data to the alerting system (via an SNMP trap, for example). When it comes to power data, there are three primary levels of detail: Rack total rack power o Important for knowing how much total power is consumed at the rack and how much cooling is needed to cool the rack Rack PDU power at the rack PDU o Important for calculating the total rack power and for alerting to potential overload conditions Device power consumed by the IT device o This information provides a greater level of detail of power at the device level but can add considerably to the cost of the rack PDU o This information can also be obtained through communications with the device itself using IPMI (Intelligent Platform Management No Limits Software 6
7 Interface) or manufacturer-specific base management protocols such as ilo or idrac. Typical data captured at the rack level includes power, humidity, temperature, pressure differential, and security status. Temperature readings at the rack are important to ensure that the rack inlet temperature (the temperature of the air being drawn into the IT equipment) is sufficiently low to properly cool the equipment. Just as with power, there are multiple levels of temperature monitoring which can be done at the rack level. In the case of temperature, however, the level of monitoring comes down to the number of sensors and their placement within the rack. One typical choice is to have three temperature sensors at the front of the rack low, medium and high in order to measure the inlet temperature variance across the front of the rack. Some choose to measure the rear temperature, particularly if using a hot-aisle containment system. Some choose to measure temperature at every other rack or only for selected racks. All of these are valid choices. More sensors will provide more temperature detail at a higher cost. Fewer sensors will be less expensive but will yield less overall information. Humidity readings at the rack are important to ensure that there is sufficient moisture in the air being drawn into the IT equipment. If the humidity is too high, there is a risk of condensation forming on the equipment. If the humidity is too low, there is an increased risk of static electricity. Unlike temperature sensors, there is typically only a single humidity sensor used to measure the humidity at the front of the rack. The pressure differential between the front and back of the rack is an important indication of the ability of the air to move from the cold aisle to the hot aisle, cooling the IT equipment in the process. If the pressure differential is too low, the rack will only be able to handle a certain load without exceeding a particular temperature threshold. This pressure differential can be measured with a pressure monitor at the front and the rear of the rack. Security at the rack is important if only certain people are allowed to interact with equipment within the rack. The two important parameters measurements are the lock status of the rack (if employing an electronic locking mechanism) and the door open status. Again, when determining what data is to be collected, it is important to consider how the information will be used. This will determine what sensors are needed and how often the data must be collected. Think about the key questions: What data do I need? How often do I need to measure the data? No Limits Software 7
8 20% of data center managers can take more than a day to find a server! Inventory at the Rack Level A data center can contain thousands of assets, from servers, storage and network devices to infrastructure support equipment such as PDUs, UPSs and cooling units. Keeping track of these assets is an ongoing task faced by data center managers. A Digital Realty Trust survey found that only 26% of data center managers could locate a server that had gone down within minutes. Only 58% could locate the server within 4 hours and 20% required more than a day. The inability to locate equipment in the data center increases the mean time to repair (MTTR) for the equipment and decreases the overall availability. Within a day 22% Within 4 hours 32% More than a day 20% Within minutes 26% Digital Realty Trust At the rack level, there are three primary resources which must be considered when trying to determine whether the rack can support a new asset: Is there enough contiguous space to house the asset? Is there sufficient redundant power for the asset? Is there enough cooling to remove the heat generated by the asset? Organizations can typically expect a 10% error rate in manual data entry of asset inventory. Comprehensive management of IT equipment must consider space, power and cooling at the rack level. Therefore, the inventory of the assets in the rack is required down to the rack unit. This is typically done through a manual data entry and audit process. There are drawbacks to this method, however. Manual entry is an arduous, time-consuming process that is typically rife with errors. In the Computer Associates technology brief Striving to Achieve 100% Data Accuracy: The Challenge for Next Generation Asset Management (Watson & Fulton, 2009), the authors point out the difficulty in maintaining the accuracy of this information. The authors state that Manual tracking with pen and clipboard, or even spreadsheets is time consuming and highly error-prone. Organizations can typically expect a 10% error rate in manual data entry due to typing and transcribing errors. There are other options for asset inventory at the rack level which can reduce or eliminate the manual process and its inherent errors. The two primary methods are radio frequency identification (RFID) or tethered solutions. A tethered solution ties an asset to a rack location by means of a cable or some other physical connection. No Limits Software 8
9 Using RFID to Track Assets within the Rack There are multiple vendors who provide RFID-based solutions for tracking IT assets in the data center. There are some advantages to this technology, the primary one being the ability to track an asset throughout multiple locations, from the loading dock to a staging area to the rack. As the asset is moved, it is tracked using RFID readers placed throughout the building, particularly at the entrance points to a room. RFID provides advantages over barcodes, including more storage, ability to reprogram and remote reading. There are several major advantages of an RFID tag over a barcode. First, an RFID tag can contain much more information than a barcode, which is typically limited to numbers or letters. Second, an RFID tag is reprogrammable while a barcode must be replaced if the information changes. Finally, an RFID tag can be read remotely while a barcode requires someone to manually scan it with a handheld device. RFID tags are read using RFID readers which are distributed in areas in which tags are to be read. Typically, these readers are placed in doorways, enabling the readers and associated management system to determine the zone in which the tagged asset resides. As the tagged asset is moved through a doorway, the reader will detect its presence and record where the asset is currently located. There are some drawbacks to the use of RFID in a data center. First, each tag must be programmed and installed on each asset to be tracked. Each tag is programmed with a unique identifier that is used to tie the identifier to the asset in an asset management database. This programming requires someone to gather the information about the asset and to then program this information into the tag. This manual data entry can result in errors. An alternative is to have the manufacturer program the tag with the appropriate information about the asset, including manufacturer, model and a unique asset identifier such as a serial number. RFID is designed as a proximity system, not a location system. Tracking assets to the rack unit will require equipment to be installed in each rack. It is important to understand that RFID was designed as a proximity or portal system rather than as a location system. In other words, the systems were designed to know when a tag passes a reader or passes through a portal containing a reader. To determine a more precise asset location, RFID must rely on triangulation of multiple readers which measure the return signal strength of a tag. This is a difficult task under any circumstances, but is particularly difficult in a data center environment with hundreds of racks and thousands of servers creating a noise-filled environment. In order to locate a server in a specific location within a rack, an RFID solution will require additional equipment to be installed in each rack. One method uses Near Field Communication, a short-range high frequency wireless communication technology which enables the exchange of data between devices over a very short distance. This method requires an RFID reader for each rack unit. A 42U rack would require 42 RFID readers, for example. These readers have a very short range (sometimes as low as 20 mm), which means there will be restrictions on where the tags can be placed on the asset in order to ensure the tag is close enough to the No Limits Software 9
10 reader. Proper tag mounting within the acceptable range may be difficult due to the presence of ports, power connectors and other physical limitations. Using Tethered Solutions to Track Assets within the Rack An alternative to RFID is to use a tethered solution which ties an asset to a rack location by means of a cable (typically serial or USB) or some other physical connection (one-wire, for example). These solutions are sometimes used in conjunction with an RFID solution. The combined solution uses RFID to track asset location to the room and the tethered method to get the location within the rack. There are two types of tethered solutions. The first simply relates a unique ID to a location within the rack. A second step must then be taken to correlate the ID to a specific asset. The location system may know, for example, that asset #12345 is in rack unit 24. It won t, however, know anything about asset #12345 until there is some data entry which tells the system that the asset is an HP DL360 G6 server with serial number An intelligent tethered solution can greatly reduce, or even eliminate, the manual effort required to manage asset inventory within a rack. The second type of tethered solution is an intelligent system which communicates with the asset to retrieve detailed information about the asset and its configuration. A serial cable could be used, for example, to allow communications with a server through its serial BMC (base management controller). In a similar fashion, a USB cable could be used to allow communications with a device through a USB connection. Using this type of solution, a data center technician could place a new server in a rack and connect it via a serial or USB cable to a communications port indicating the position of the asset in the rack. Communication would be automatically established with the asset, which would then be identified. This method eliminates the manual process of linking an asset with a unique identifier. In addition, this type of solution can retrieve configuration information about the server. Detailed information such as hardware (processor, memory, disk drives, and network), operating system, serial numbers, installed software, virtual machines, and so on can be quickly and accurately retrieved from the asset. In addition, as the configuration of the server changes (software installed, hardware added, etc.), this information can be automatically logged as a change to the system. The Rack Just Got a Lot Smarter By breaking it down to the rack level, overall data center management can be simplified while at the same time providing the ability to more closely manage the resource requirements of IT assets. The easiest way to manage to this level is for the rack to become an intelligent device. By installing an intelligent controller and touch screen, the result is an intelligent cabinet which can provide detailed rack-level data. With connections to existing rack management hardware, the intelligent cabinet can provide the following functionality: No Limits Software 10
11 Asset management location of all rack assets down to the rack unit Power management rack PDU and overall rack power management Rack security access monitoring and lock control via badge or keypad Environmental monitoring temperature, humidity, air flow, and other sensors KVM access to rack devices through a KVM switch Touch screen and keyboard at the front of the rack Benefits of an intelligent cabinet include enhanced management, a single rack IP address, detailed data right at the rack, automated inventory control and the ability to easily retrofit existing racks. Besides the obvious advantages of enhanced management of the resources needed for the IT assets, there are other key benefits to an intelligent cabinet system. First, there is a single IP address to the rack. All of the devices within the rack (rack PDU, KVM, sensors, and so on) use a private rack network for communication. This provides enhanced security while also greatly reducing the number of IP addresses required within the data center. The touch screen on the front of the rack provides all pertinent data and functionality from a single source. Rack inventory, power usage, outlet control, environmental conditions, KVM access and rack security are all available directly from the rack. There is no need to leave the rack to gather information from a DCIM solution, spreadsheet or other tools because all of the required information is readily available. Power connections can be mapped at the rack level directly from the touch screen, so there is no need to record the connections and then later enter them into another system. The intelligent cabinet can help to manage power by verifying the power redundancy of devices within the rack as well as warning of potential failover conditions. For example, if one rack PDU fails within the rack, the resultant failover load may cause the remaining rack PDU to also fail by exceeding its power capacity. The result is that what looked to be a redundant configuration is, in fact, dependent on a single rack PDU. The intelligent cabinet can intelligently monitor both rack PDUs and warn of potential failover conditions. Another benefit of the intelligent cabinet is that all new assets added to the rack will be automatically added to the rack inventory (down to the rack unit) and this information can then be automatically pushed up to a centralized DCIM solution. The intelligent cabinet solution can be easily retrofitted into existing racks by communicating with equipment already installed in the rack. The controller can communicate with a wide range of components by simply extending the software capabilities. The components of a typical intelligent cabinet system would include the following: 1) Intelligent Controller 2) Router routes all internal network traffic on private rack network 3) Monitored rack PDUs monitor and control power to the outlet level 4) Asset Location System (both RFID and serial solutions are supported) a. RFID Near-field readers to determine asset location within the rack (requires RFID tags to be pre-configured) No Limits Software 11
12 b. Serial Communicates with assets to determine asset location and other asset details (no pre-configuration required) 5) Environmental Sensors 6) Touch Screen 7) Intelligent Cabinet Interface software which can communicate with multiple rack controllers to provide centralized control of rack security, controller upgrades, and system settings across multiple racks, as well as informing management personnel of warning and critical alerts in the data center Intelligent cabinets can simplify data center management while also providing better management of resources at the rack level. Summary Even with the proper tools, managing a data center is a difficult task due to the number of assets and the complex relationships between space, power, and cooling which must be balanced. The problem can be simplified by breaking the large, complex data center environment into more manageable segments the racks. Doing this simplifies the overall management while providing the added benefit of more closely monitoring the resource requirements of the IT equipment. Adding intelligence to the racks allows data center managers to create intelligent cabinets, single points of information at the critical rack level. Intelligent cabinets can provide asset management, power monitoring and control, rack security, environmental monitoring, KVM access and a single source of information at the rack itself. This information can be fed to a DCIM solution to provide an overall management solution which can address capacity planning at both data center and rack levels. About No Limits Software No Limits Software is a leading provider of data center infrastructure management (DCIM) solutions, including asset and change management, capacity planning and real-time monitoring. The Rack Management Platform (RaMP) solution automates asset and change management, dramatically reduces the time to find and repair equipment, improves system availability and increases data center energy efficiency by providing accurate capacity planning. No Limits Software is working with multiple partners to add intelligence to racks to help data center managers more effectively operate their data center. No Limits Software was founded in 2009 by industry experts in data center monitoring and management solutions. To learn more, visit or [email protected]. No Limits Software 12
13 Works Cited Chernicoff, D. (2011). The Shortcut Guide to Data Center Energy Efficiency. Realtime Publishers. Rasmussen, N. (2005). Guidelines for Specification of Data Center Power Density. APC. Rasmussen, N. (2011). Power and Cooling Capacity Management for Data Centers. APC. Ton, M., & Fortenbury, B. (2005). High Performance Buildings: Data Centers Uninterruptible Power Supplies (UPS). Lawrence Berkeley National Laboratory. Watson, T., & Fulton, J. (2009, March). Striving to Achieve 100% Data Accuracy: The Challenge for Next Generation Asset Management. Retrieved from No Limits Software 13
Data Center Management
Data Center Management Searching for the Optimum Solution Management of assets in the data center is incomplete, inaccurate, and difficult to maintain with today s technology No Limits Software White Paper
The Real Cost of Manual Asset Management
The Real Cost of Manual Asset Management No Limits Software White Paper #3 By David Cole 2011 No Limits Software. All rights reserved. No part of this publication may be used, reproduced, photocopied,
RaMP Data Center Manager. Data Center Infrastructure Management (DCIM) software
RaMP Data Center Manager Data Center Infrastructure Management (DCIM) software One solution for both IT and facilities managers As data centers become more complex, it becomes increasingly important to
MAXIMIZING YOUR DATA CENTER INFRASTRUCTURE: CENTRALIZED MANAGEMENT AND WIRE-FREE ENVIRONMENTAL MONITORING
MAXIMIZING YOUR DATA CENTER INFRASTRUCTURE: CENTRALIZED MANAGEMENT AND WIRE-FREE Chris C. Gaskins Vice President of Product Development RF Code, Inc. AUGUST 2010 Shawn Griggs Director of Product Management
Power Management. Raritan Description. http://www.raritan.com/products/power-management/
Raritan Description Raritan is a proven innovator of power management, infrastructure management, KVM and serial solutions for data centers of all sizes. In more than 50,000 locations worldwide, our hardware
Management and Wireless in the Data Center
SOLUTIONS BRIEF Management and Wireless in the Data Center High Performance Wireless Networks Management and Wireless in the Data Center Worldwide demand for new and more powerful IT-based applications,
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room
Comprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara Framework to provide full convergence of
Improve competiveness of IDC and enterprise data centers with DCIM
Improve competiveness of IDC and enterprise data centers with DCIM This paper studies the implementation of modern DCIM systems for data centers to improve operational competitiveness with ATEN's DCIM
Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning
Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning 2009, Raritan Inc. Overview Corporate America is more dependent than ever on computing
Preparing for Your First DCIM System Deployment: Auto-Discovery and Data Collection
Table of Contents What is Auto-Discovery? Where is My Data and How Can I Get It? Why Auto-Discovery is Not Enough Where to Go to Start Collecting Your Data What Does an Operational DCIM System Provide?
Comprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara framework to provide full convergence of
Data Center Infrastructure Management (DCIM) Demystified
software is quickly becoming the core engine of data center operations. Only 5 years ago, manual spreadsheets, sometimes supplemented with Visio diagrams, were accepted as the default tools for data center
Managing Cooling Capacity & Redundancy In Data Centers Today
Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS
Integrated Wire-Free Solution for Monitoring Power and Environment with RF Code and Sentry Power Manager (SPM)
Integrated Wire-Free Solution for Monitoring Power and Environment with RF Code and Sentry Power Manager (SPM) Purpose This technical note describes the components and process of the new power and environmental
Server Technology, Inc.
Server Technology, Inc. Cabinet Power Monitoring, Management & Control Within the Data Center White Paper STI-100-011 2010-Sept-27 by Calvin Nicholson, Senior Director Software and Strategic Alliances,
APC APPLICATION NOTE #92
#92 Best Practices for Designing Data Centers with the InfraStruXure InRow RC By John Niemann Abstract The InfraStruXure InRow RC is designed to provide cooling at the row and rack level of a data center
Airflow Simulation Solves Data Centre Cooling Problem
Airflow Simulation Solves Data Centre Cooling Problem The owner s initial design for a data centre in China utilized 40 equipment racks filled with blade servers spread out in three rows along the length
Best Practices for Wire-free Environmental Monitoring in the Data Center
White Paper 11800 Ridge Parkway Broomfiled, CO 80021 1-800-638-2638 http://www.42u.com [email protected] Best Practices for Wire-free Environmental Monitoring in the Data Center Introduction Monitoring for
5 Reasons. Environment Sensors are used in all Modern Data Centers
5 Reasons Environment Sensors are used in all Modern Data Centers TABLE OF CONTENTS 5 Reasons Environmental Sensors are used in all Modern Data Centers Save on Cooling by Confidently Raising Data Center
Power & Environmental Monitoring
Data Centre Monitoring Made Easy Power & Environmental Monitoring Features & Benefits Packet Power provides the easiest, most cost effective way to capture detailed power and temperature information for
The role of Access and Control in DCIM
Data Center Infrastructure Management for System Administrators The role of Access and Control in DCIM Table of Contents 1. Executive Summary... 3 2. Server Access & Control... 4 2.1 Remote Access Tools
Model Manage Monitor Maximize your Data Center
NetZoomDC is the most feature rich, fully-scalable, enterprise Data Center Infrastructure Management (DCIM) software application. It enables data center professionals to Model, Manage, Monitor and Maximize
Packet Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution
Data Center Solutions for Data Centers provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility operations. Gain
Better Data Center IT Asset Management through. Art Barton, Director of RFID Strategies, RFTrail
Better Data Center IT Asset Management through Smart RFID-Enabled Software Art Barton, Director of RFID Strategies, RFTrail IT asset managers and facilities managers for Data Centers worldwide are being
Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions
Data Centre Solutions... energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration
Application Briefs: Remote Office Environment
Overview Remote offices are a definite sign of growth, but it can constitute an immense challenge from an IT infrastructure standpoint. Remote offices may include a wide variety of wiring closets and small
Revolutionizing Data Center Infrastructure Management
Infrastructure Management & Monitoring for Business-Critical Continuity TM Revolutionizing Data Center Infrastructure Management The Trellis Platform A Real-Time Solution to Continuous Performance Improvement
Best Practices in. Best IT Asset Management through Smart RFID-Enabled Software. Art Barton, Director of RFID Strategies, RFTrail
Best Practices in RFID-Enabled Asset Management Best IT Asset Management through Smart RFID-Enabled Software Art Barton, Director of RFID Strategies, RFTrail Chief Information Officers, finance managers,
Automating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011
Automating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011 Opportunities in Automating Infrastructure Why Automation in Data Center? Tiers, compartments and complexity Work
The Avocent Data Center Planner Real-World Insight for Smarter Data Center Management
Infrastructure Management & Monitoring for Business-Critical Continuity TM The Avocent Data Center Planner Real-World Insight for Smarter Data Center Management EXECUTION AVAILABILITY EFFICIENCY What s
Technologies for Data Centres
Technologies for Data Centres BlueNet at a glance // PHILOSOPHY A passion for innovation page 5 // ENERGY MANAGEMENT The latest in efficiency page 7 // HIGH AVAILABILITY Seamless and systematic security
Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy
Data Center Solutions Packet Power for Data Centers Packet Power provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
PE6108/PE6208/PE8108/PE8208
Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency
Introducing Tripp Lite s PowerAlert Network Management Software
Introducing Tripp Lite s PowerAlert Network Management Software What Can It Do For You? Improve the accuracy and efficiency of the network operations staff in the context of power and environmental management
AIR-SITE GROUP. White Paper. Green Equipment Room Practices
AIR-SITE GROUP White Paper Green Equipment Room Practices www.air-site.com Common practices to build a green equipment room 1 Introduction Air-Site (www.air-site.com) is a leading international provider
Data Center Infrastructure Management: How to Optimize Data Center Operations
Data Center Infrastructure Management: How to Optimize Data Center Operations Khaled Nassoura, PE [email protected] General Manager Raritan, Inc. Question of the Day Question: Would any CFO run
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Environmental Data Center Management and Monitoring
2013 Raritan Inc. Table of Contents Introduction Page 3 Sensor Design Considerations Page 3 Temperature and Humidity Sensors Page 4 Airflow Sensor Page 6 Differential Air Pressure Sensor Page 6 Water Sensor
Unified Infrastructure Monitoring, Access and Control
A White Paper from the Experts in Business-Critical Continuity Unified Infrastructure Monitoring, Access and Control Streamline Infrastructure Management with a Single, Multi-Purpose Appliance the Avocent
Energy Management Solutions
Energy Management Solutions Introducing the world s most innovative intelligent Power Distribution Units (ipdus) designed to simplify rack energy and environmental management of your data center. Enlogic
Using DCIM to Identify Data Center Efficiencies and Cost Savings. Chuck Kramer, RCDD, NTS [email protected]
Using DCIM to Identify Data Center Efficiencies and Cost Savings Chuck Kramer, RCDD, NTS [email protected] Data Center Eco-System (A 3 layer cake) Physical Layer IT Layer Application Layer DECOMMISIONING
Wireless in the Data Centre becomes best practice!
Wireless in the Data Centre becomes best practice! Mobile computing has made wireless networking essential almost everywhere. Until recently the Data Centre was excluded from this advance but this is now
Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
Applying Data Center Infrastructure Management in Collocation Data Centers
Applying Data Center Infrastructure Management in Collocation Data Centers Infrastructure Management & Monitoring for Business-Critical Continuity TM Applying Data Center Infrastructure Management (DCIM)
Re Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
Intel Data Center Manager. Data center IT agility and control
Intel Data Center Manager Data center IT agility and control The Data Center Ecosystem 2 Why do we care about Data Center Management? attributed to devices connected to the Internet of Everything (up from
Data Center Power Distribution and Capacity Planning:
Data Center Power Distribution and Capacity Planning: Understanding what you know and don t know about power usage in your data center 2009, Raritan Inc. About This Series Raritan, a leading provider of
Server Technology, Inc.
Server Technology, Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2009-April-07 Headquarters Server Technology, Inc. 1040 Sandhill
How To Improve Energy Efficiency In A Data Center
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
InfraStruxure TM Management Software
InfraStruxure TM Management Software End to end data centre infrastructure management software for monitoring and control of power, cooling, security and energy usage from the building through IT systems
Cheat Sheets to Data Center Infrastructure Management
^ Business-wise, Future-drivenTM Cheat Sheets to Data Center Infrastructure Management The Brands You Trust. Table of Contents Introduction...3 How DCIM helps operations...4 How DCIM helps planning...5
Rack Power Distribution. Worldwide
Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data
Server Room, Data Centre Management and Monitoring Solutions
Server Room, Data Centre Management and Monitoring Solutions Published in October 2007 Management & Monitoring Solutions The ability to alert a business to disasters or potential performance issues at
Colocation and Cloud Hosting Solutions. Build a strong and efficient physical infrastructure that delivers service reliability and profitability
Colocation and Cloud Hosting Solutions Build a strong and efficient physical infrastructure that delivers service reliability and profitability 2 Dependability and Deployment Speed that Improves Your Bottom
Data Center Energy Efficiency Looking Beyond PUE
Data Center Energy Efficiency Looking Beyond PUE No Limits Software White Paper #4 By David Cole 2011 No Limits Software. All rights reserved. No part of this publication may be used, reproduced, photocopied,
Rack Power Distribution
The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:
Understanding the Promise of (DCIM)
Understanding the Promise of Data Center Infrastructure Management (DCIM) Chuck Kramer, RCDD, NTS, CDCP, CDFOM Senior Solutions Consultant Emerson Network Power What is DCIM? The monitoring, collection
DATA CENTER INFRASTRUCTURE MANAGEMENT
THE nlyte SOLUTION nlyte Software was founded by data center professionals for data center professionals and is the independent provider of data center infrastructure Management (DCIM) solutions. The nlyte
Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability
Considerations for a Highly Available Intelligent Rack Power Distribution Unit A White Paper on Availability Introduction Data centers are currently undergoing a period of great change. Data center managers
Data Centre Best Practices Summary
Data Centre Best Practices Summary Delivering Successful Technology Rooms 1 END2END s Data Centre Best Practices END2END design Data Centres/Computer Rooms based on 7 major principles: Understanding the
Data Centre Infrastructure Assessment
Data Centre Infrastructure Assessment Prepared for: ACME INC SAMPLE REPORT Attention: Mr DC Manager This report represents a generic sample data centre audit for a generic customer by Focus Group Technologies.
DCIM Software and IT Service Management - Perfect Together
DCIM Software and IT Service Management - Perfect Together A White Paper from Raritan 2014 Raritan Inc Overview Information Technology is so fundamental to every business today that every organization
(Examples of various colocation sites)
Overview The largest factor involved in maintaining business servers today are the fixed costs associated with data centers. The Colocation Environment is an outsourcing model whereby a colocation company
How To Power A Bladecenter H Servers
Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications
THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER
Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR
Includes customer case study. February 28, 2013
Advances in Wire-Free Power and Environmental Monitoring in the Data Center Open Architecture API Integration capabilities offer the ultimate flexibility when using intelligent cabinet PDU Technology/
Major Risks and Recommended Solutions
Major Risks and Recommended Solutions www.icdsecurity.com OVERVIEW Are you familiar with the main security risks that threaten data centers? This paper provides an overview of the most common and major
DATA CENTER SOLUTIONS
DATA CENTER SOLUTIONS Nobody Makes Better Data Center Equipment Maximize availability, manageability and efficiency with cost-effective solutions from a dependable partner. Provide reliable, efficient
The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM)
The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM) TM IS YOUR DATA CENTER OPERATING AT PEAK PERFORMANCE? MITIGATE RISK. OPTIMIZE EFFICIENCY. SUPPORT
Data center upgrade proposal. (phase one)
Data center upgrade proposal (phase one) Executive Summary Great Lakes began a recent dialogue with a customer regarding current operations and the potential for performance improvement within the The
How to Measure Energy Consumption in Your Data Center
How to Measure Energy Consumption in Your Data Center Gartner RAS Core Research Note G00205428, Rakesh Kumar, 8 September 2010, R3506 02112011 This research outlines a pragmatic approach that should be
Optimized Network Monitoring
Optimized Network Monitoring Four ways matrix switching streamlines data center operation, reduces costs and positions IT for growth WHITE PAPER MARCH 2008 APCON, Inc. T 503.682.4050 800.624.6808 F 503.682.4059
Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert
Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate
Managing Data Centre Heat Issues
Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design
Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM
Power Management Strategies for High-Density IT Facilities and Systems A White Paper from the Experts in Business-Critical Continuity TM Executive Summary Increases in data center density and diversity
Dynamic Power Variations in Data Centers and Network Rooms
Dynamic Power Variations in Data Centers and Network Rooms By Jim Spitaels White Paper #43 Revision 2 Executive Summary The power requirement required by data centers and network rooms varies on a minute
Data Centre Infrastructure Management DCIM. Where it fits with what s going on
Data Centre Infrastructure Management DCIM Where it fits with what s going on ITIL reducing IT OPEX by 25% ITIL is about processes these are defined in two main areas ITIL Service Delivery processes :
Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems
NER Data Corporation White Paper Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems Introduction Data centers are
TNC is an open architecture for network access control. If you re not sure what NAC is, we ll cover that in a second. For now, the main point here is
1 2 This slide shows the areas where TCG is developing standards. Each image corresponds to a TCG work group. In order to understand Trusted Network Connect, it s best to look at it in context with the
Data Center Technology: Physical Infrastructure
Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider
Power Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM
Data Center Rack Systems Key to Business-Critical Continuity A White Paper from the Experts in Business-Critical Continuity TM Executive Summary At one time, data center rack enclosures and related equipment
InfraStruxure Data Centre Management Software. Holistic open standards integrated data centre management solution.
Data Centre Solutions...energy efficient by design InfraStruxure Data Centre Management Software Holistic open standards integrated data centre management solution. Creating an effective workspace environment
StruxureWare TM Data Center Operation
StruxureWare TM Data Center End to end Management (DCIM) software for monitoring, control of power, cooling, security and energy usage from the building through IT systems Part of StruxureWare for Data
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly
Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009
Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of