Foreseer Services. Product application guide. Table of contents
|
|
|
- Steven Miles
- 10 years ago
- Views:
Transcription
1 Product application guide Foreseer Services Table of contents 1.0 General What are Foreseer Software and Engineering Services Foreseer Service Categories How to use the Product Application Guide Matching your application Matching your devices and device manufacturers I just want to get started with my project, where do I go? Data center and co-location infrastructure applications Application description Key requirements Communications diagram Application screenshots Industrial facility applications Application description Key requirements Communications diagram Application screenshots Healthcare sector applications Application description Key requirements Communications diagram Application screenshots Telecom/CATV applications Application description Key requirements Communications diagram Application screenshots Financial institution applications Application description Key requirements Communications diagram Application screenshots Education sector applications Application description Key requirements Communications diagram Application screenshots Government sector applications Application description Key requirements Communications diagram Application screenshots
2 10.0 Custom applications Air conditioner monitoring and control Introduction Features Tools Scheduled maintenance and alarm management application Introduction Features Tools Branch circuit monitoring Description Application requirements: Application screenshot: Power flow monitoring Description Application requirements: Application screenshot: Services Hardware compatibility list Supported protocol list Supported device categories and vendors UPS s Power distribution equipment Meters Circuit protection Transfer switches Drives HVAC Environmental monitoring Protocols BMS Generators Chillers Security and safety Fuel monitoring PLC s Leak detection Lighting control Other Tyical options & accessories list Software functionality list Foreseer Server functions Foreseer WebViews functions Message Management functions Advanced Applications functions Custom dashboards Maintenance manager AC control Energy cost allocation Capacity assessment How to get started with your project Foreseer Services Hotline Contact your local Eaton Foreseer Services Marketing Manager EATON CORPORATION Foreseer Services Product Application Guide
3 1.0 General Welcome to the Foreseer Services Product Application Guide. This guide provides information on how Foreseer Services are typically implemented and configured in different types of infrastructures and environments. Each main implementation section of the guide provides information about the key requirements for that specific application in question and includes an implementation example diagram with typical components, as well as example screenshots of what the applications graphical user interface (GUI) may look like. This guide also details the typical hardware options and accessories used with Foreseer Services along with supported protocols, device categories and vendors. In addition it will point you to additional information available on the topics, e.g. to the Hardware Compatibility List that details specifics of devices supported. Typical Foreseer Services available, software functionality, and how to get started with a project are described towards the end of the guide along with some typical terminology and acronyms. 1.1 What are Foreseer Software and Engineering Services Foreseer Software and Engineering Services provide vendor-neutral power and energy infrastructure integration solutions that help companies reduce energy consumption and unplanned downtime due to the failure of critical power, environmental, safety or security systems. For more information including product brochure and marketing collaterals, please visit out web site at or Foreseer Service Categories Foreseer Services have been categorized into three main categories as shown in Figure 1 below. Foreseer Services Software Services Project Management Services Engineering Services Figure 1: Foreseer Services have been categorized into three main categories. 1. Software Services Foreseer Software was developed from the ground up to support thousands of devices, connections, device parameters and data logging. It is fully scalable to support a single data center, or multiple facilities no matter where they are in the world. It facilitates monitoring of infrastructure pieces, including HVAC, UPS, power distribution systems (meters, motor control, variable frequency drives, etc.), generators, fire-detection, security systems, and other communicating sub-systems from hundreds of manufacturers all on one screen. Software Services Foreseer Software Classes Secure Web Server Redundant Web Server Power Xpert Reporting Manager of Managers (MOM) Other Custom Applications Upgrades Class upgrades Version upgrades Figure 2: Software Services cover all aspects from choosing the right class of software to custom application development and redundancy requirements. EATON CORPORATION 3
4 2. Engineering Services Foreseer Engineering Services provide you with the full array of services needed to design, install, and commission your monitoring solution. Engineering Services Hardware Services Installation Services Follow Up Services Gateways, Data Acqusition Engines, Terminals, CPU Turnkey Installations Startup System Startup & Commissioning Third-Party Software Integration Training 7/24 Support Service Contracts Training Engineering Services Design Services Commissioning Services System Services Specification Development Third-Party Device & Comms Driver Development Custom GUI Development System Testing Point-to-Point Commissioning Options Figure 3: Engineering Services covers all aspects of system design, communications, hardware, installation and follow up services requirements. 3. Project Management Services Each Foreseer integration project may be customized with a full range of services to fulfill even the most demanding requirements. Services may be selected to fit the immediate and long-term needs of the installation. Figure 4: A dedicated Project Manager is assigned to each project along with a project team. The customer is consulted and kept up to speed each step of the way with formal approval requirements. 4 EATON CORPORATION Foreseer Services Product Application Guide
5 2.0 How to use the Product Application Guide 2.1 Matching your application Please use the table of contents to identify which application is the closest match to your environment and general infrastructure. Then review the key requirements for that particular section along with associated implementation and configuration example diagrams. Once you have matched up your application details, please browse to section 11 to review the typical Foreseer Services that you may require, and then go to section 15 to find out how to get started with your project. 2.2 Matching your devices and device manufacturers Match up the devices that you currently have, and are planning to include in the future, to the device and vendor list in section 12. If necessary review the detailed Hardware Compatibility List available on the Internet to ensure compatibility as described in this section. Once you have matched up your devices, please browse to section 11 to review the typical Foreseer Services that you may require, and then go to section 15 to find out how to get started with your project. 2.3 I just want to get started with my project, where do I go? Please browse to section 11 to review the typical Foreseer Services that you may require and then go to section 15 to find out how to get started with your project. Foreseer Services is a full scale integration package that can be customized to fit all your needs from simple project management and system design to full turn key, multiple site redundant system delivery around the globe. 3.0 Data center and co-location infrastructure applications 3.1 Application description Key success requirements for data centers include maximizing system availability and energy efficiency. Other important factors include generating capacity reports and automatically calculating PUE and DCiE metrics, ensuring load balancing and monitoring your environment as well as your greenhouse gas footprint. Benchmark your energy use, record the sequence of events at a 1 millisecond time resolution, and extend your critical infrastructure life with this comprehensive monitoring solution. 3.2 Key requirements ( = most important, «= less important ) Importance Requirement Description ««Software & Hardware 1 millisecond event timestamp resolution Millisecond based timestamp support enables understanding the sequence of rapidly occurring events and putting necessary mitigation plans in place Alarm Notification Notify locally and remotely occurring alarm events Data Center and Energy Management Fully scalable from a single data center to multiple facilities around the world Solution scalability DC Power Plant Monitoring Monitor battery banks and detect/replace bad strings to avoid costly downtime and maximize equipment service life Emergency Power and Fuel Level Monitor generators and emergency power fuel levels Monitoring Event Prediction Predict upcoming issues utilizing a trend projection graph Fire and Safety monitoring Detect fire and smoke as well as occurring leaks (fuel, water, acid) High Availability Installation of power quality products (UPS, TVSS, PDU, Generators etc.) to minimize unscheduled downtime due to power quality related issues High Security Enable high level of encryption for data access and server-client communications Holistic enterprise view of the system Monitor facilities and Data Center infrastructures around the country, or/and the globe Lighting Control Lighting control high level event integration into Foreseer System Load balancing Balance electrical loads to minimize peak demand and maximize energy cost savings PLC Monitoring Cost effective and simple way to monitor a multitude of PLC linked to critical equipment PowerChain Management Monitor all the devices in the power distribution system power chain including environmental factors, safety and security systems and connections to other monitoring systems in the facility e.g. Building Management Systems Power Measurement Installation of metering products to understand energy consumption and realize energy savings EATON CORPORATION 5
6 Power Quality Measurement Installation of metering products to understand sags, swells, transients, harmonics, power factor etc. PUE and DCiE Energy Efficiency reporting, benchmarking and improvement tracking Rack level cooling monitoring Understanding of cooling at the rack level Security Monitoring Utilize IFrames to bring in CCTV, monitor open/closed door to the rack level, integrate high level building security event notification into the software Sequence of Events recording Installation of Sequence of Events recording devices to understand the order of occurring events Temperature, humidity and environmental monitoring Installation of sensors to monitor temperature, humidity and detect leaks (fuel, water, acid) as well as differential pressure Third party device integration Foreseer Software is vendor neutral and supports most third-party devices using their native communication protocol, a standard protocol or a protocol gateway. Programmers develop new drivers as needed during the project Weather Monitoring/Lightning detection Monitoring and alarm notification of upcoming weather conditions and severe weather preparedness Reporting Branch Circuit Monitoring Report Capacity info with understanding of redundant sources. Determine circuit loading levels at-aglance with color-coded graphics indicating loading against capacity Capacity Summary Report The summary of top and bottom loaded circuits as well as loading details for each circuit according to user defined date/time range and facility hierarchy location Data Center Efficiency Report A summary of data center infrastructure efficiency (DCiE) metrics and power usage effectiveness (PUE) including temperature and humidity. Benchmark, improve and track progress «Energy Cost Allocation Report The total energy bill ($) dollar value or cost per kwh across a facility hierarchy for a user defined date/time range Energy Summary Report The summary of consumption (kwh) and demand (kw) for a user defined date/time range and facility hierarchy location Event Summary Report Provides a Pareto-chart of occurred events according to user defined date/time range and facility hierarchy location Greenhouse Gas Report Captures the six offensive greenhouse gasses: Carbon Dioxide, Sulfur Dioxide, Nitrogen Oxide, Mercury, Methane, and Nitrous Oxide broken down by selected locations within a facility N/A Joint Commission Report Generate a standard JCAHO compliant report to support hospital power test requirements. Check events, key metrics of generators, Automatic Transfer Switches during generator testing at user defined date/time time range and facility hierarchy location Power Quality Report The distribution and trend for amps, volts, THD according to user defined date/time range and facility hierarchy location «Utilities Report Understand and track your utilities (water, air, gas, electricity, steam) consumption, and how effective your improvement efforts have been with day-to-day bar and line charts «Other Other custom reports deemed necessary. NOTE: Power Xpert Reporting utilizes standard SQL database storage making it easy to create custom reports with third-party software if necessary. Custom Applications A/C Control The A/C interface offers comprehensive monitoring and optional lead/lag control for Air Flow, Data Aire and Liebert air conditioning units. Lead/lag control and scheduling is viewable via a Web-browser and is controllable with the proper user authority Branch Circuit Monitoring Monitor Branch Circuits from small 42 circuit panels to a fully configured PDU with multiple 84 circuit panels or any configuration of distribution panels. Includes current and watts for each circuit or pole from the panels but can be extended to any data available via an integration protocol with the hardware. Optional advanced features such as totaling breakers for an N+1 application or per customer are supported Capacity Planning Planning electrical usage and demand is a difficult job. As site loads increase and usage patterns change, demand on a device may grow beyond its intended capacity. And, while average demand may not be a concern, peak demand always is. Even a momentary spike has the potential to bring down an entire network. Foreseer Software tracks the kw and kva over time, immediately informs of peak levels, and projects future demands based on past usage. This knowledge is critical in planning for electrical upgrades and/or changes to the power chain to support changing load patterns Dashboard Various GUI Dashboards are available for specific applications and configurations: Data Center Risk Analysis Power Outage Power Capacity Executive Maintenance Scheduler The maintenance scheduler offers the ability to preset scheduled (weekly or periodic) maintenance windows within the system to disarm selected devices on which maintenance will be performed. Disarming the devices allows continued monitoring and archiving during the maintenance period while disabling alarms and preventing unnecessary notification of personnel 6 EATON CORPORATION Foreseer Services Product Application Guide
7 3.3 Communications diagram Figure 5: The typical Data Center/Co-Location device mixture includes a large variety of power distribution, cooling, environmental monitoring, lighting, safety and security, backup and emergency power systems that have been purchased over a long period of time. Foreseer Services integrates all of these systems into a simple, single software monitoring package. Support for metering and energy measurement including greenhouse gas monitoring are requirements that need to be taken into consideration as well as e.g. Building Management System integration. 3.4 Application screenshots A A B C D E F G H I J K Webviews example data summary: A. Utility Power Feed 1 & 2 B. UPS Status C. Data Center Power D. PDU Loading E. Generator Status F. Battery System Status G. Data Center Efficiency H. Cooling System Status I. Data Center Environment J. Weather Conditions K. Foreseer Software Status Figure 6: The above example is a single Webview of the most critical elements of Data Center/ Co-location infrastructure. Individual data screens display summary information on backup power, cooling, power quality, energy consumption, environment and weather, which are vital to be able to run a mission critical system at maximum efficiency and uptime. Webviews look and feel can be configured and customized to include mimic screens and any available data including ones derived from complex formulas. EATON CORPORATION 7
8 Webview example data summary: A B G C D B G A F A. B. C. D. E. F. G. Redundant backup power capacity PDU level power capacity Data Center rack-level power capacity Load Balancing overview Backup power distribution analysis Capacity analysis Color coded online and remote event notification E E A A E G E Figure 7: (Optional feature). The Power Capacity View provides an at-a-glance simple analysis of the data centers electrical capacity. Normal, cautionary and alarm events are triggered automatically, both online and remotely once a threshold has been reached. Mapping the data centers capacity is critical for power, cooling and redundancy planning. With Foreseer Software projection graphing capability, data center managers can easily predict when they are going to hit a capacity threshold going into the future and prepare accordingly. Webview example data summary: A C E A. B. C. D. E. PDU level power capacity Data Center rack-level power capacity Load Balancing overview Capacity analysis Color coded online and remote event notification D B Figure 8: The Rack Row-level Power Capacity view provides an at-a-glance visual overview of A and B side loading as well as the racks total current utilization. Color coded gauges clearly indicate the alarm notification thresholds and available capacity. With Foreseer Software projection graphing capability, data center managers can easily predict when they are going to hit a capacity threshold going into the future and prepare accordingly. 8 EATON CORPORATION Foreseer Services Product Application Guide
9 Webview example data summary: A. Device physical location data B. Color-coded device status overview C. Drill down capability Figure 9: This Floor Plan graphic provides an at-a-glance overview of all the monitored devices on the floor and their corresponding color-coded and animated status indicators. Device objects are clickable and enable the user to drill down into device level details for additional visual and physical information. Floor Plans and blueprints of the facilities can be easily imported into the Foreseer System and modified to fit the user s needs. Webview example data summary: A. Color-coded Enterprise wide device status bubble up and overview B. Drill down capability C. Alarm Notifications D. 3D modeling and floor plan E. Campus layout example F. Global status tracking and event presentation Figure 10: This multi-view graphic offers a customized enterprise level overview of the most important sites, systems, locations and campuses running the Foreseer systems along with associated color-coded alarms. The users can immediately take action based on visual, audible alarms and via remote notification through , SMS, pagers or real-time event printing depending on the best practices in place. EATON CORPORATION 9
10 Webview example data summary: A. Color-coded device status bubble up and overview B. Drill down capability C. Alarm Notifications D. 3D floor plan Figure 11: (Optional feature). This 3D floor plan modeling example graphic illustrates the capabilities of presenting highly accurate visual positioning of devices along with their associated status can be displayed within the Foreseer Software framework. Device labels are color-coded displaying the current status. The users can immediately take action based on visual, audible alarms and via remote notification through , SMS, pagers or real-time event printing depending on the best practices in place. Webview example data summary: A. Input voltage, current and frequency B. Output voltage, current and frequency C. UPS status indicators D. Separate alarm category section E. Battery status indicators and available runtime Figure 12: This Data Center UPS equipment view example displays at-a-glance the most critical data coming from a UPS system. Input, output, status and alarms along with battery information provide a great inner view into the UPSs overall performance. Note that fields for system location and e.g. battery maintenance schedule can be made available automatically. 10 EATON CORPORATION Foreseer Services Product Application Guide
11 4.0 Industrial facility applications 4.1 Application description Industrial and production facilities, in addition to typical power quality, energy management, efficiency and device maintenance requirements, need all systems to work seamlessly in a rugged shop floor environment. Utilities consumption (Water, Air, Gas, Electricity, Steam) and metering along with load balancing for peak demand minimizing, energy cost allocation are key requirements that need to go from the bottom floor to the top floor. 4.2 Key requirements ( = most important, «= less important ) Importance Requirement Description Software & Hardware «1 millisecond event timestamp resolution Millisecond based timestamp support enables understanding the sequence of rapidly occurring events and putting necessary mitigation plans in place Alarm Notification Notify locally and remotely occurring alarm events ««Data Center and Energy Management Solution scalability Fully scalable from a single data center to multiple facilities around the world «DC Power Plant Monitoring Monitor battery banks and detect/replace bad strings to avoid costly downtime and maximize equipment service life Emergency Power and Fuel Level Monitor generators and emergency power fuel levels Monitoring Event Prediction Predict upcoming issues utilizing a trend projection graph Fire and Safety monitoring Detect fire and smoke as well as occurring leaks (fuel, water, acid) High Availability Installation of power quality products (UPS, TVSS, PDU, Generators etc.) to minimize unscheduled downtime due to power quality related issues «High Security Enable high level of encryption for data access and server-client communications Holistic enterprise view of the system Monitor facilities and Data Center infrastructures around the country, or/and the globe Lighting Control Lighting control high level event integration into Foreseer System Load balancing Balance electrical loads to minimize peak demand and maximize energy cost savings «PLC Monitoring Cost effective and simple way to monitor a multitude of PLC linked to critical equipment PowerChain Management Monitor all the devices in the power distribution system power chain including environmental factors, safety and security systems and connections to other monitoring systems in the facility e.g. Building Management Systems Power Measurement Installation of metering products to understand energy consumption and realize energy savings Power Quality Measurement Installation of metering products to understand sags, swells, transients, harmonics, power factor etc. «PUE and DCiE Energy Efficiency reporting, benchmarking and improvement tracking «Rack level cooling monitoring Utilize IFrames to bring in CCTV, monitor open/closed door to the rack level, integrate high level building security event notification into the software Understanding of cooling at the rack level Installation of Sequence of Events recording devices to understand the order of occurring events Security Monitoring Utilize IFrames to bring in CCTV, monitor open/closed door to the rack level, integrate high level building security event notification into the software «Sequence of Events recording Installation of Sequence of Events recording devices to understand the order of occurring events Temperature, humidity and environmental monitoring Installation of sensors to monitor temperature, humidity and detect leaks (fuel, water, acid) as well as differential pressure Third party device integration Foreseer Software is vendor neutral and supports most third-party devices using their native communication protocol, a standard protocol or a protocol gateway. Programmers develop new drivers as needed during the project «Weather Monitoring/Lightning detection Monitoring and alarm notification of upcoming weather conditions and severe weather preparedness Reporting «Branch Circuit Monitoring Report Capacity info with understanding of redundant sources. Determine circuit loading levels at-a-glance with color-coded graphics indicating loading against capacity «Capacity Summary Report The summary of top and bottom loaded circuits as well as loading details for each circuit according to user defined date/time range and facility hierarchy location «Data Center Efficiency Report A summary of data center infrastructure efficiency (DCiE) metrics and power usage effectiveness (PUE) including temperature and humidity. Benchmark, improve and track progress «Energy Cost Allocation Report The total energy bill ($) dollar value or cost per kwh across a facility hierarchy for a user defined date/time range «Energy Summary Report The summary of consumption (kwh) and demand (kw) for a user defined date/time range and facility hierarchy location EATON CORPORATION 11
12 Event Summary Report Provides a Pareto-chart of occurred events according to user defined date/time range and facility hierarchy location Greenhouse Gas Report Captures the six offensive greenhouse gasses: Carbon Dioxide, Sulfur Dioxide, Nitrogen Oxide, Mercury, Methane, and Nitrous Oxide broken down by selected locations within a facility «Joint Commission Report Generate a standard JCAHO compliant report to support hospital power test requirements. Check events, key metrics of generators, Automatic Transfer Switches during generator testing at user defined date/time time range and facility hierarchy location Power Quality Report The distribution and trend for amps, volts, THD according to user defined date/time range and facility hierarchy location «Utilities Report Understand and track your utilities (water, air, gas, electricity, steam) consumption, and how effective your improvement efforts have been with day-to-day bar and line charts «Other Other custom reports deemed necessary Custom Applications A/C Control The A/C interface offers comprehensive monitoring and optional lead/lag control for Air Flow, Data Aire and Liebert air conditioning units. Lead/lag control and scheduling is viewable via a Web-browser and is controllable with the proper user authority «Branch Circuit Monitoring Monitor Branch Circuits from small 42 circuit panels to a fully configured PDU with multiple 84 circuit panels or any configuration of distribution panels. Includes current and watts for each circuit or pole from the panels but can be extended to any data available via an integration protocol with the hardware. Optional advanced features such as totaling breakers for an N+1 application or per customer are supported Capacity Planning Planning electrical usage and demand is a difficult job. As site loads increase and usage patterns change, demand on a device may grow beyond its intended capacity. And, while average demand may not be a concern, peak demand always is. Even a momentary spike has the potential to bring down an entire network. Foreseer Software tracks the kw and kva over time, immediately informs of peak levels, and projects future demands based on past usage. This knowledge is critical in planning for electrical upgrades and/or changes to the power chain to support changing load patterns Dashboard Various GUI Dashboards are available for specific applications and configurations: Data Center Risk Analysis Power Outage Power Capacity Maintenance Scheduler The maintenance scheduler offers the ability to preset scheduled (weekly or periodic) maintenance windows within the system to disarm selected devices on which maintenance will be performed. Disarming the devices allows continued monitoring and archiving during the maintenance period while disabling alarms and preventing unnecessary notification of personnel 4.3 Communications diagram 4.4 Application screenshots 12 EATON CORPORATION Foreseer Services Product Application Guide
13 5.0 Healthcare sector applications 5.1 Application description Enhancing patient treatment and safety, along with improving operational efficiencies are requirements that can be achieved at higher levels only with a strong foundation of having security, safety, IT and electrical equipment functioning reliably, efficiently and without interruption, and in accordance to industry rules and regulations including Joint Commission compliancy. Foreseer Services offer value-add applications for the healthcare sector that empower organizations to maximize system uptime, reliability and provide a wealth of information for future improvements on power quality and energy management as well as device lifetime expectancy. In addition Foreseer software can provide educated predictions with projection graphing to foresee brewing issues before they become real problems. 5.2 Key requirements ( = most important, «= less important ) Importance Requirement Description Software & Hardware «1 millisecond event timestamp resolution Millisecond based timestamp support enables understanding the sequence of rapidly occurring events and putting necessary mitigation plans in place Alarm Notification Notify locally and remotely occurring alarm events Data Center and Energy Management Fully scalable from a single data center to multiple facilities around the world Solution scalability DC Power Plant Monitoring Monitor battery banks and detect/replace bad strings to avoid costly downtime and maximize equipment service life Emergency Power and Fuel Level Monitor generators and emergency power fuel levels Monitoring Event Prediction Predict upcoming issues utilizing a trend projection graph Fire and Safety monitoring Detect fire and smoke as well as occurring leaks (fuel, water, acid) High Availability Installation of power quality products (UPS, TVSS, PDU, Generators etc.) to minimize unscheduled downtime due to power quality related issues High Security Enable high level of encryption for data access and server-client communications Holistic enterprise view of the system Monitor facilities and Data Center infrastructures around the country, or/and the globe Lighting Control Lighting control high level event integration into Foreseer System «Load balancing Balance electrical loads to minimize peak demand and maximize energy cost savings «PLC Monitoring Cost effective and simple way to monitor a multitude of PLC linked to critical equipment PowerChain Management Monitor all the devices in the power distribution system power chain including environmental factors, safety and security systems and connections to other monitoring systems in the facility e.g. Building Management Systems Power Measurement Installation of metering products to understand energy consumption and realize energy savings Power Quality Measurement Installation of metering products to understand sags, swells, transients, harmonics, power factor etc. «PUE and DCiE Energy Efficiency reporting, benchmarking and improvement tracking «Rack level cooling monitoring Understanding of cooling at the rack level Security Monitoring Utilize IFrames to bring in CCTV, monitor open/closed door to the rack level, integrate high level building security event notification into the software «Sequence of Events recording Installation of Sequence of Events recording devices to understand the order of occurring events Temperature, humidity and environmental monitoring Installation of sensors to monitor temperature, humidity and detect leaks (fuel, water, acid) as well as differential pressure Third party device integration Foreseer Software is vendor neutral and supports most third-party devices using their native communication protocol, a standard protocol or a protocol gateway. Programmers develop new drivers as needed during the project Weather Monitoring/Lightning detection Monitoring and alarm notification of upcoming weather conditions and severe weather preparedness Reporting «Branch Circuit Monitoring Report Capacity info with understanding of redundant sources. Determine circuit loading levels at-a-glance with color-coded graphics indicating loading against capacity «Capacity Summary Report The summary of top and bottom loaded circuits as well as loading details for each circuit according to user defined date/time range and facility hierarchy location «Data Center Efficiency Report A summary of data center infrastructure efficiency (DCiE) metrics and power usage effectiveness (PUE) including temperature and humidity. Benchmark, improve and track progress «Energy Cost Allocation Report The total energy bill ($) dollar value or cost per kwh across a facility hierarchy for a user defined date/time range EATON CORPORATION 13
14 Energy Summary Report The summary of consumption (kwh) and demand (kw) for a user defined date/time range and facility hierarchy location Event Summary Report Provides a Pareto-chart of occurred events according to user defined date/time range and facility hierarchy location Greenhouse Gas Report Captures the six offensive greenhouse gasses: Carbon Dioxide, Sulfur Dioxide, Nitrogen Oxide, Mercury, Methane, and Nitrous Oxide broken down by selected locations within a facility Joint Commission Report Generate a standard JCAHO compliant report to support hospital power test requirements. Check events, key metrics of generators, Automatic Transfer Switches during generator testing at user defined date/time time range and facility hierarchy location Power Quality Report The distribution and trend for amps, volts, THD according to user defined date/time range and facility hierarchy location Utilities Report Understand and track your utilities (water, air, gas, electricity, steam) consumption, and how effective your improvement efforts have been with day-to-day bar and line charts «Other Other custom reports deemed necessary Custom Applications «A/C Control The A/C interface offers comprehensive monitoring and optional lead/lag control for Air Flow, Data Aire and Liebert air conditioning units. Lead/lag control and scheduling is viewable via a Web-browser and is controllable with the proper user authority «Branch Circuit Monitoring Monitor Branch Circuits from small 42 circuit panels to a fully configured PDU with multiple 84 circuit panels or any configuration of distribution panels. Includes current and watts for each circuit or pole from the panels but can be extended to any data available via an integration protocol with the hardware. Optional advanced features such as totaling breakers for an N+1 application or per customer are supported Capacity Planning Planning electrical usage and demand is a difficult job. As site loads increase and usage patterns change, demand on a device may grow beyond its intended capacity. And, while average demand may not be a concern, peak demand always is. Even a momentary spike has the potential to bring down an entire network. Foreseer Software tracks the kw and kva over time, immediately informs of peak levels, and projects future demands based on past usage. This knowledge is critical in planning for electrical upgrades and/or changes to the power chain to support changing load patterns Dashboard Various GUI Dashboards are available for specific applications and configurations: Data Center Risk Analysis Power Outage Power Capacity Maintenance Scheduler The maintenance scheduler offers the ability to preset scheduled (weekly or periodic) maintenance windows within the system to disarm selected devices on which maintenance will be performed. Disarming the devices allows continued monitoring and archiving during the maintenance period while disabling alarms and preventing unnecessary notification of personnel 5.3 Communications diagram 14 EATON CORPORATION Foreseer Services Product Application Guide
15 5.4 Application screenshots 6.0 Telecom/CATV applications 6.1 Application description DC to DC power plants required for telecommunications and CATV applications demand rigorous battery, power transfer, and associated emergency power monitoring capabilities. All battery events are categorized and logged for retrospective analysis. Individual battery cells in the battery strings are continuously checked, and bad cells are identified for replacement. It is also critical to automatically keep track of service intervals and set the monitoring system into maintenance mode to avoid unnecessary alarms as well as alarm escalation to service personnel on duty. In addition these types of applications require stringent environmental monitoring including temperature, humidity, leak detection (acid, water, fuel) and emergency power fuel level monitoring. AC to DC converters along with Foreseer Capacity planning application enables the minimization of peak demand fluctuations and maximizes energy cost savings along with energy and event summary reporting associated with installed metering products. Other typical add on applications include Foreseer Services AC Control, Dashboards and the Maintenance Scheduler. EATON CORPORATION 15
16 6.2 Key requirements ( = most important, «= less important ) Importance Requirement Description Software & Hardware «1 millisecond event timestamp resolution Millisecond based timestamp support enables understanding the sequence of rapidly occurring events and putting necessary mitigation plans in place Alarm Notification Notify locally and remotely occurring alarm events «Data Center and Energy Management Fully scalable from a single data center to multiple facilities around the world Solution scalability DC Power Plant Monitoring Monitor battery banks and detect/replace bad strings to avoid costly downtime and maximize equipment service life Emergency Power and Fuel Level Monitor generators and emergency power fuel levels Monitoring Event Prediction Predict upcoming issues utilizing a trend projection graph Fire and Safety monitoring Detect fire and smoke as well as occurring leaks (fuel, water, acid) High Availability Installation of power quality products (UPS, TVSS, PDU, Generators etc.) to minimize unscheduled downtime due to power quality related issues High Security Enable high level of encryption for data access and server-client communications Holistic enterprise view of the system Monitor facilities and Data Center infrastructures around the country, or/and the globe «Lighting Control Lighting control high level event integration into Foreseer System Load balancing Balance electrical loads to minimize peak demand and maximize energy cost savings «PLC Monitoring Cost effective and simple way to monitor a multitude of PLC linked to critical equipment PowerChain Management Monitor all the devices in the power distribution system power chain including environmental factors, safety and security systems and connections to other monitoring systems in the facility e.g. Building Management Systems Power Measurement Installation of metering products to understand energy consumption and realize energy savings «Power Quality Measurement Installation of metering products to understand sags, swells, transients, harmonics, power factor etc. «PUE and DCiE Energy Efficiency reporting, benchmarking and improvement tracking «Rack level cooling monitoring Understanding of cooling at the rack level Security Monitoring Utilize IFrames to bring in CCTV, monitor open/closed door to the rack level, integrate high level building security event notification into the software «Sequence of Events recording Installation of Sequence of Events recording devices to understand the order of occurring events Temperature, humidity and environmental monitoring Installation of sensors to monitor temperature, humidity and detect leaks (fuel, water, acid) as well as differential pressure Third party device integration Foreseer Software is vendor neutral and supports most third-party devices using their native communication protocol, a standard protocol or a protocol gateway. Programmers develop new drivers as needed during the project «Weather Monitoring/Lightning detection Monitoring and alarm notification of upcoming weather conditions and severe weather preparedness Reporting «Branch Circuit Monitoring Report Capacity info with understanding of redundant sources. Determine circuit loading levels at-aglance with color-coded graphics indicating loading against capacity Capacity Summary Report The summary of top and bottom loaded circuits as well as loading details for each circuit according to user defined date/time range and facility hierarchy location «Data Center Efficiency Report A summary of data center infrastructure efficiency (DCiE) metrics and power usage effectiveness (PUE) including temperature and humidity. Benchmark, improve and track progress «Energy Cost Allocation Report The total energy bill ($) dollar value or cost per kwh across a facility hierarchy for a user defined date/time range Energy Summary Report The summary of consumption (kwh) and demand (kw) for a user defined date/time range and facility hierarchy location Event Summary Report Provides a Pareto-chart of occurred events according to user defined date/time range and facility hierarchy location «Greenhouse Gas Report Captures the six offensive greenhouse gasses: Carbon Dioxide, Sulfur Dioxide, Nitrogen Oxide, Mercury, Methane, and Nitrous Oxide broken down by selected locations within a facility «Joint Commission Report Generate a standard JCAHO compliant report to support hospital power test requirements. Check events, key metrics of generators, Automatic Transfer Switches during generator testing at user defined date/time time range and facility hierarchy location «Power Quality Report The distribution and trend for amps, volts, THD according to user defined date/time range and facility hierarchy location «Utilities Report Understand and track your utilities (water, air, gas, electricity, steam) consumption, and how effective your improvement efforts have been with day-to-day bar and line charts «Other Other custom reports deemed necessary 16 EATON CORPORATION Foreseer Services Product Application Guide
17 Custom Applications A/C Control The A/C interface offers comprehensive monitoring and optional lead/lag control for Air Flow, Data Aire and Liebert air conditioning units. Lead/lag control and scheduling is viewable via a Web-browser and is controllable with the proper user authority «Branch Circuit Monitoring Monitor Branch Circuits from small 42 circuit panels to a fully configured PDU with multiple 84 circuit panels or any configuration of distribution panels. Includes current and watts for each circuit or pole from the panels but can be extended to any data available via an integration protocol with the hardware. Optional advanced features such as totaling breakers for an N+1 application or per customer are supported Capacity Planning Planning electrical usage and demand is a difficult job. As site loads increase and usage patterns change, demand on a device may grow beyond its intended capacity. And, while average demand may not be a concern, peak demand always is. Even a momentary spike has the potential to bring down an entire network. Foreseer Software tracks the kw and kva over time, immediately informs of peak levels, and projects future demands based on past usage. This knowledge is critical in planning for electrical upgrades and/or changes to the power chain to support changing load patterns Dashboard Various GUI Dashboards are available for specific applications and configurations: Data Center Risk Analysis Power Outage Power Capacity Maintenance Scheduler The maintenance scheduler offers the ability to preset scheduled (weekly or periodic) maintenance windows within the system to disarm selected devices on which maintenance will be performed. Disarming the devices allows continued monitoring and archiving during the maintenance period while disabling alarms and preventing unnecessary notification of personnel 6.3 Communications diagram EATON CORPORATION 17
18 6.4 Application screenshots 18 EATON CORPORATION Foreseer Services Product Application Guide
19 7.0 Financial institution applications 7.1 Application description Secure, real-time transactions and mission critical back-office operations along with IT, security, safety, environmental and building management integration for maximum uptime are key considerations for financial institutions. In addition energy, utilities measurement and management functionality, including benchmarking, progress tracking, coupled with greenhouse gas footprint recognition and full scale third party device integration are key success factors that Foreseer Services can provide to financial institutions. 7.2 Key requirements ( = most important, «= less important ) Importance Requirement Description ««Software & Hardware 1 millisecond event timestamp resolution Millisecond based timestamp support enables understanding the sequence of rapidly occurring events and putting necessary mitigation plans in place Alarm Notification Notify locally and remotely occurring alarm events Data Center and Energy Management Fully scalable from a single data center to multiple facilities around the world Solution scalability DC Power Plant Monitoring Monitor battery banks and detect/replace bad strings to avoid costly downtime and maximize equipment service life Emergency Power and Fuel Level Monitor generators and emergency power fuel levels Monitoring Event Prediction Predict upcoming issues utilizing a trend projection graph Fire and Safety monitoring Detect fire and smoke as well as occurring leaks (fuel, water, acid) High Availability Installation of power quality products (UPS, TVSS, PDU, Generators etc.) to minimize unscheduled downtime due to power quality related issues High Security Enable high level of encryption for data access and server-client communications Holistic enterprise view of the system Monitor facilities and Data Center infrastructures around the country, or/and the globe Lighting Control Lighting control high level event integration into Foreseer System Load balancing Balance electrical loads to minimize peak demand and maximize energy cost savings PLC Monitoring Cost effective and simple way to monitor a multitude of PLC linked to critical equipment PowerChain Management Monitor all the devices in the power distribution system power chain including environmental factors, safety and security systems and connections to other monitoring systems in the facility e.g. Building Management Systems Power Measurement Installation of metering products to understand energy consumption and realize energy savings Power Quality Measurement Installation of metering products to understand sags, swells, transients, harmonics, power factor etc. PUE and DCiE Energy Efficiency reporting, benchmarking and improvement tracking Rack level cooling monitoring Understanding of cooling at the rack level EATON CORPORATION 19
20 Security Monitoring Utilize IFrames to bring in CCTV, monitor open/closed door to the rack level, integrate high level building security event notification into the software Sequence of Events recording Installation of Sequence of Events recording devices to understand the order of occurring events Temperature, humidity and environmental monitoring Installation of sensors to monitor temperature, humidity and detect leaks (fuel, water, acid) as well as differential pressure Third party device integration Foreseer Software is vendor neutral and supports most third-party devices using their native communication protocol, a standard protocol or a protocol gateway. Programmers develop new drivers as needed during the project Weather Monitoring/Lightning detection Monitoring and alarm notification of upcoming weather conditions and severe weather preparedness Reporting Branch Circuit Monitoring Report Capacity info with understanding of redundant sources. Determine circuit loading levels at-aglance with color-coded graphics indicating loading against capacity Capacity Summary Report The summary of top and bottom loaded circuits as well as loading details for each circuit according to user defined date/time range and facility hierarchy location Data Center Efficiency Report A summary of data center infrastructure efficiency (DCiE) metrics and power usage effectiveness (PUE) including temperature and humidity. Benchmark, improve and track progress Energy Cost Allocation Report The total energy bill ($) dollar value or cost per kwh across a facility hierarchy for a user defined date/time range Energy Summary Report The summary of consumption (kwh) and demand (kw) for a user defined date/time range and facility hierarchy location Event Summary Report Provides a Pareto-chart of occurred events according to user defined date/time range and facility hierarchy location Greenhouse Gas Report Captures the six offensive greenhouse gasses: Carbon Dioxide, Sulfur Dioxide, Nitrogen Oxide, Mercury, Methane, and Nitrous Oxide broken down by selected locations within a facility «Joint Commission Report Generate a standard JCAHO compliant report to support hospital power test requirements. Check events, key metrics of generators, Automatic Transfer Switches during generator testing at user defined date/time time range and facility hierarchy location Power Quality Report The distribution and trend for amps, volts, THD according to user defined date/time range and facility hierarchy location Utilities Report Understand and track your utilities (water, air, gas, electricity, steam) consumption, and how effective your improvement efforts have been with day-to-day bar and line charts Other Other custom reports deemed necessary Custom Applications A/C Control The A/C interface offers comprehensive monitoring and optional lead/lag control for Air Flow, Data Aire and Liebert air conditioning units. Lead/lag control and scheduling is viewable via a Web-browser and is controllable with the proper user authority Branch Circuit Monitoring Monitor Branch Circuits from small 42 circuit panels to a fully configured PDU with multiple 84 circuit panels or any configuration of distribution panels. Includes current and watts for each circuit or pole from the panels but can be extended to any data available via an integration protocol with the hardware. Optional advanced features such as totaling breakers for an N+1 application or per customer are supported Capacity Planning Planning electrical usage and demand is a difficult job. As site loads increase and usage patterns change, demand on a device may grow beyond its intended capacity. And, while average demand may not be a concern, peak demand always is. Even a momentary spike has the potential to bring down an entire network. Foreseer Software tracks the kw and kva over time, immediately informs of peak levels, and projects future demands based on past usage. This knowledge is critical in planning for electrical upgrades and/or changes to the power chain to support changing load patterns Dashboard Various GUI Dashboards are available for specific applications and configurations: Data Center Risk Analysis Power Outage Power Capacity Maintenance Scheduler The maintenance scheduler offers the ability to preset scheduled (weekly or periodic) maintenance windows within the system to disarm selected devices on which maintenance will be performed. Disarming the devices allows continued monitoring and archiving during the maintenance period while disabling alarms and preventing unnecessary notification of personnel 20 EATON CORPORATION Foreseer Services Product Application Guide
21 7.3 Communications diagram 7.4 Application screenshots 8.0 Education sector applications 8.1 Application description From K-12 schools to multiple far-flung University Campuses, they all have rigorous requirements for power quality, energy management, security, safety and environmental monitoring covering the facilities as well as the IT Data Centers. Power Usage Effectiveness, cost allocation, utilities consumption and energy summary along with custom applications are key requirements for the educational sector. 8.2 Key requirements ( = most important, «= less important ) Importance Requirement Description Software & Hardware 1 millisecond event timestamp resolution Millisecond based timestamp support enables understanding the sequence of rapidly occurring events and putting necessary mitigation plans in place Alarm Notification Notify locally and remotely occurring alarm events Data Center and Energy Management Solution scalability Fully scalable from a single data center to multiple facilities around the world «DC Power Plant Monitoring Monitor battery banks and detect/replace bad strings to avoid costly downtime and maximize equipment service life Emergency Power and Fuel Level Monitor generators and emergency power fuel levels Monitoring Event Prediction Predict upcoming issues utilizing a trend projection graph Fire and Safety monitoring Detect fire and smoke as well as occurring leaks (fuel, water, acid) High Availability Installation of power quality products (UPS, TVSS, PDU, Generators etc.) to minimize unscheduled downtime due to power quality related issues EATON CORPORATION 21
22 High Security Enable high level of encryption for data access and server-client communications Holistic enterprise view of the system Monitor facilities and Data Center infrastructures around the country, or/and the globe Lighting Control Lighting control high level event integration into Foreseer System Load balancing Balance electrical loads to minimize peak demand and maximize energy cost savings PLC Monitoring Cost effective and simple way to monitor a multitude of PLC linked to critical equipment PowerChain Management Monitor all the devices in the power distribution system power chain including environmental factors, safety and security systems and connections to other monitoring systems in the facility e.g. Building Management Systems Power Measurement Installation of metering products to understand energy consumption and realize energy savings Power Quality Measurement Installation of metering products to understand sags, swells, transients, harmonics, power factor etc. PUE and DCiE Energy Efficiency reporting, benchmarking and improvement tracking Rack level cooling monitoring Understanding of cooling at the rack level Security Monitoring Utilize IFrames to bring in CCTV, monitor open/closed door to the rack level, integrate high level building security event notification into the software Sequence of Events recording Installation of Sequence of Events recording devices to understand the order of occurring events Temperature, humidity and environmental monitoring Installation of sensors to monitor temperature, humidity and detect leaks (fuel, water, acid) as well as differential pressure Third party device integration Foreseer Software is vendor neutral and supports most third-party devices using their native communication protocol, a standard protocol or a protocol gateway. Programmers develop new drivers as needed during the project Weather Monitoring/Lightning detection Monitoring and alarm notification of upcoming weather conditions and severe weather preparedness Reporting Branch Circuit Monitoring Report Capacity info with understanding of redundant sources. Determine circuit loading levels at-aglance with color-coded graphics indicating loading against capacity Capacity Summary Report The summary of top and bottom loaded circuits as well as loading details for each circuit according to user defined date/time range and facility hierarchy location Data Center Efficiency Report A summary of data center infrastructure efficiency (DCiE) metrics and power usage effectiveness (PUE) including temperature and humidity. Benchmark, improve and track progress Energy Cost Allocation Report The total energy bill ($) dollar value or cost per kwh across a facility hierarchy for a user defined date/time range Energy Summary Report The summary of consumption (kwh) and demand (kw) for a user defined date/time range and facility hierarchy location Event Summary Report Provides a Pareto-chart of occurred events according to user defined date/time range and facility hierarchy location Greenhouse Gas Report Captures the six offensive greenhouse gasses: Carbon Dioxide, Sulfur Dioxide, Nitrogen Oxide, Mercury, Methane, and Nitrous Oxide broken down by selected locations within a facility «Joint Commission Report Generate a standard JCAHO compliant report to support hospital power test requirements. Check events, key metrics of generators, Automatic Transfer Switches during generator testing at user defined date/time time range and facility hierarchy location Power Quality Report The distribution and trend for amps, volts, THD according to user defined date/time range and facility hierarchy location Utilities Report Understand and track your utilities (water, air, gas, electricity, steam) consumption, and how effective your improvement efforts have been with day-to-day bar and line charts «Other Other custom reports deemed necessary Custom Applications A/C Control The A/C interface offers comprehensive monitoring and optional lead/lag control for Air Flow, Data Aire and Liebert air conditioning units. Lead/lag control and scheduling is viewable via a Web-browser and is controllable with the proper user authority Branch Circuit Monitoring Monitor Branch Circuits from small 42 circuit panels to a fully configured PDU with multiple 84 circuit panels or any configuration of distribution panels. Includes current and watts for each circuit or pole from the panels but can be extended to any data available via an integration protocol with the hardware. Optional advanced features such as totaling breakers for an N+1 application or per customer are supported Capacity Planning Planning electrical usage and demand is a difficult job. As site loads increase and usage patterns change, demand on a device may grow beyond its intended capacity. And, while average demand may not be a concern, peak demand always is. Even a momentary spike has the potential to bring down an entire network. Foreseer Software tracks the kw and kva over time, immediately informs of peak levels, and projects future demands based on past usage. This knowledge is critical in planning for electrical upgrades and/or changes to the power chain to support changing load patterns Dashboard Various GUI Dashboards are available for specific applications and configurations: Data Center Risk Analysis Power Outage Power Capacity Maintenance Scheduler The maintenance scheduler offers the ability to preset scheduled (weekly or periodic) maintenance windows within the system to disarm selected devices on which maintenance will be performed. Disarming the devices allows continued monitoring and archiving during the maintenance period while disabling alarms and preventing unnecessary notification of personnel 22 EATON CORPORATION Foreseer Services Product Application Guide
23 8.3 Communications diagram 8.4 Application screenshots EATON CORPORATION 23
24 9.0 Government sector applications 9.1 Application description Government agencies, aviation and military applications all require rigorous security and safety specifications fulfillment according to existing best practices as well as laws and regulations. Power quality and systems reliability need to be at the highest possible levels. In addition what-if scenarios modeling, projection graphing along with statistical analysis are key requirements. For government operated facilities and departments, energy measurement and power usage effectiveness along with cost allocation are also major contributors and in many cases mandatory requirements abiding to the Energy Policy Act of Also adherence to the Energy Independence and Security Act of 2007, as well as many executive orders, are critical success factors. 9.2 Key requirements ( = most important, «= less important ) Importance Requirement Description Software & Hardware «1 millisecond event timestamp resolution Millisecond based timestamp support enables understanding the sequence of rapidly occurring events and putting necessary mitigation plans in place Alarm Notification Notify locally and remotely occurring alarm events Data Center and Energy Management Solution scalability Fully scalable from a single data center to multiple facilities around the world «DC Power Plant Monitoring Monitor battery banks and detect/replace bad strings to avoid costly downtime and maximize equipment service life Emergency Power and Fuel Level Monitor generators and emergency power fuel levels Monitoring Event Prediction Predict upcoming issues utilizing a trend projection graph Fire and Safety monitoring Detect fire and smoke as well as occurring leaks (fuel, water, acid) High Availability Installation of power quality products (UPS, TVSS, PDU, Generators etc.) to minimize unscheduled downtime due to power quality related issues High Security Enable high level of encryption for data access and server-client communications Holistic enterprise view of the system Monitor facilities and Data Center infrastructures around the country, or/and the globe Lighting Control Lighting control high level event integration into Foreseer System Load balancing Balance electrical loads to minimize peak demand and maximize energy cost savings PLC Monitoring Cost effective and simple way to monitor a multitude of PLC linked to critical equipment PowerChain Management Monitor all the devices in the power distribution system power chain including environmental factors, safety and security systems and connections to other monitoring systems in the facility e.g. Building Management Systems Power Measurement Installation of metering products to understand energy consumption and realize energy savings Power Quality Measurement Installation of metering products to understand sags, swells, transients, harmonics, power factor etc. PUE and DCiE Energy Efficiency reporting, benchmarking and improvement tracking Rack level cooling monitoring Understanding of cooling at the rack level Security Monitoring Utilize IFrames to bring in CCTV, monitor open/closed door to the rack level, integrate high level building security event notification into the software «Sequence of Events recording Installation of Sequence of Events recording devices to understand the order of occurring events Temperature, humidity and environmental monitoring Installation of sensors to monitor temperature, humidity and detect leaks (fuel, water, acid) as well as differential pressure Third party device integration Foreseer Software is vendor neutral and supports most third-party devices using their native communication protocol, a standard protocol or a protocol gateway. Programmers develop new drivers as needed during the project Weather Monitoring/Lightning detection Monitoring and alarm notification of upcoming weather conditions and severe weather preparedness Reporting «Branch Circuit Monitoring Report Capacity info with understanding of redundant sources. Determine circuit loading levels at-aglance with color-coded graphics indicating loading against capacity Capacity Summary Report The summary of top and bottom loaded circuits as well as loading details for each circuit according to user defined date/time range and facility hierarchy location Data Center Efficiency Report A summary of data center infrastructure efficiency (DCiE) metrics and power usage effectiveness (PUE) including temperature and humidity. Benchmark, improve and track progress Energy Cost Allocation Report The total energy bill ($) dollar value or cost per kwh across a facility hierarchy for a user defined date/time range Energy Summary Report The summary of consumption (kwh) and demand (kw) for a user defined date/time range and facility hierarchy location 24 EATON CORPORATION Foreseer Services Product Application Guide
25 Event Summary Report Provides a Pareto-chart of occurred events according to user defined date/time range and facility hierarchy location Greenhouse Gas Report Captures the six offensive greenhouse gasses: Carbon Dioxide, Sulfur Dioxide, Nitrogen Oxide, Mercury, Methane, and Nitrous Oxide broken down by selected locations within a facility «Joint Commission Report Generate a standard JCAHO compliant report to support hospital power test requirements. Check events, key metrics of generators, Automatic Transfer Switches during generator testing at user defined date/time time range and facility hierarchy location Power Quality Report The distribution and trend for amps, volts, THD according to user defined date/time range and facility hierarchy location Utilities Report Understand and track your utilities (water, air, gas, electricity, steam) consumption, and how effective your improvement efforts have been with day-to-day bar and line charts «Other Other custom reports deemed necessary Custom Applications «A/C Control The A/C interface offers comprehensive monitoring and optional lead/lag control for Air Flow, Data Aire and Liebert air conditioning units. Lead/lag control and scheduling is viewable via a Web-browser and is controllable with the proper user authority «Branch Circuit Monitoring Monitor Branch Circuits from small 42 circuit panels to a fully configured PDU with multiple 84 circuit panels or any configuration of distribution panels. Includes current and watts for each circuit or pole from the panels but can be extended to any data available via an integration protocol with the hardware. Optional advanced features such as totaling breakers for an N+1 application or per customer are supported «Capacity Planning Planning electrical usage and demand is a difficult job. As site loads increase and usage patterns change, demand on a device may grow beyond its intended capacity. And, while average demand may not be a concern, peak demand always is. Even a momentary spike has the potential to bring down an entire network. Foreseer Software tracks the kw and kva over time, immediately informs of peak levels, and projects future demands based on past usage. This knowledge is critical in planning for electrical upgrades and/or changes to the power chain to support changing load patterns Dashboard Various GUI Dashboards are available for specific applications and configurations: Data Center Risk Analysis Power Outage Power Capacity «Maintenance Scheduler The maintenance scheduler offers the ability to preset scheduled (weekly or periodic) maintenance windows within the system to disarm selected devices on which maintenance will be performed. Disarming the devices allows continued monitoring and archiving during the maintenance period while disabling alarms and preventing unnecessary notification of personnel 9.3 Communications diagram EATON CORPORATION 25
26 9.4 Application screenshots 26 EATON CORPORATION Foreseer Services Product Application Guide
27 10.0 Custom applications 10.1 Air conditioner monitoring and control Introduction The Foreseer Software AC interface offers comprehensive monitoring and optional lead/lag control for Data Aire and Liebert air conditioning units. Lead/lag control and scheduling is viewable from any Foreseer client and is controllable with the proper user authority Features Zone assignment/support for all AC units based on N+1 or N+2 standby scheme. Primary and secondary schedules allow easy changeover for weekends/holidays. AC auto changeover on a unit basis by selectable standby schedule or user selected critical alarms. Lead/Lag standby rotation with 8 hour to 30 day schedule. Standby unit activation by temperature threshold from embedded or externally monitored temperature sensors. Manual control of any unit in an On/Off/Standby mode. Zone inhibit function to block different AC s within a zone from humidifying/dehumidifying or heating/cooling at the same time. All scheduling or manual control password protected Tools Alarm Actions view: Off Alarm settings Used to indicate which alarms will cause a unit to be controlled off and cause the current standby unit to be controlled on. Standby Alarm settings For selection of alarms that will cause a Standby unit to supplement the zone until the alarm is cleared from the On unit. Zone Assignment view: Allows grouping of AC s into geographically controlled zones Primary/secondary schedule initial status, set s the initial startup for each AC. Allows ON/OFF/AUTO manual control for each AC. Schedule Setup view: Rotation Day/Time, used to enable and select rotation frequency of standby unit(s) Secondary schedule, used to enable and control the secondary menu start date/time and stop date/time EATON CORPORATION 27
28 Control Logic view: Temperature zone override, used to start the standby unit within a zone if the units in the zone are unable to keep cooling within a specified deadband from the average setpoint. Zone inhibit control, used to enable the zone inhibit functionality and set the temperature and humidity tolerance which activate the inhibit. Figure 13: AC Control Alarm Actions View Figure 14: AC Control Logic View 28 EATON CORPORATION Foreseer Services Product Application Guide
29 Figure 15: AC Control Schedule Setup View Figure 16: AC Control Zone Assignment View 10.2 Scheduled maintenance and alarm management application Introduction The Eaton Foreseer Software maintenance scheduler offers the ability to preset scheduled (weekly or periodic) maintenance windows within the Foreseer Software System to disarm selected devices maintenance will be performed on. Disarming the devices will allow all continued monitoring and archiving during the maintenance period while disabling alarms from occurring and Message Management from unnecessarily notifying personnel Features Single button for Enable/Disable of entire schedule Schedule by the day of week or monthly date Easily select/review devices that will be disarmed Single view allows control/review of all settings All scheduling and control password protected EATON CORPORATION 29
30 Tools Maintenance Schedule Control View Allows complete control for up to 30 devices. Multiple views may be installed grouping like equipment per view or splitting electrical/mechanical equipment. Includes the ability to manually disarm any of the listed equipment with a simple right click control menu, password protected. Automatically indicates when the schedule setup is invalid, only allows for a maximum 48 hour window. Figure 17: Maintenance Schedule Control View 10.3 Branch circuit monitoring Description Foreseer Software fully supports all aspects of Branch Circuit Monitoring from a small 42 circuit panel to a fully configured PDU with multiple 84 circuit panels or any configuration of distribution panels. Support for Branch Circuit Monitoring typically includes current and watts for each circuit or pole from the panels but can be extended to any data available via an integration protocol with the hardware. Included are default alarm settings for 70% cautionary and 80% critical of the rated breaker size. The user interface with this driver is a graphical representation depicting the panel itself and including breaker sizes, number of poles per breaker and breaker load assignments. The end user is also supplied tools and a user s guide for keeping the panel graphics and schedules up to date as dynamic changes are implemented within the application. Optional advanced features such as totaling breakers for an N+1 application or per customer are easily implemented Application requirements Current panel schedules for as delivered implementation will provide the customer with most complete and accurate system from the start. Any changes to the default alarm settings are easiest implemented prior to configuration. 30 EATON CORPORATION Foreseer Services Product Application Guide
31 Application screenshot 10.4 Power flow monitoring Description Foreseer has the ability to bring your electrical oneline to life. Actual energized/de-energized conditions can be presented on any area of the electrical oneline where equipment is being monitored. ATS, STS, Breakers and disconnect switches all dynamically show current position as reported to Foreseer Application requirements Accurate AutoCAD drawing of the Electrical Oneline Application screenshot EATON CORPORATION 31
32 11.0 Services Typical design services System Design and bill of material development and recommendations Specification development, drawings and documentation Third Party device, communication interface and driver design and development Interactive software user interface design, please contact us Typical installation services Complete project management services Complete Turn-key installation options System installation and startup services System testing and customization 50% - 95% - 100% custom installation drawing package Customized graphic layouts and backgrounds Facility and equipment mimic graphics One-line layouts development Customized device gauges and status indicators Custom software installation and configuration Device configuration, setup and testing Custom software and application development Third Party Software integration Reporting setup and configuration Basic Foreseer System training, please contact us Typical commissioning services Overall system testing Tiered systems testing Full point-point system commissioning options, please contact us Typical follow-up services Connectivity devices installation, configuration, testing and customization Eaton Hardware integration Third Party Hardware integration device configuration, setup and testing activities Advanced Foreseer System customer training 7 x 24 technical support Customized service contract w/scheduled site visits, please contact us 32 EATON CORPORATION Foreseer Services Product Application Guide
33 12.0 Hardware compatibility list Please refer to the Foreseer Services Hardware Compatibility List. Latest version is posted on Supported protocol list Modbus RTU Modbus TCP SNMP BACnet IP OPC LONworks Multiple proprietary protocols 12.2 Supported device categories and vendors UPS s APC Best Power Borri Caterpillar Chloride Eaton Exide GE IPM Liebert MGE Mitsubishi Piller Power Tecnique Powerware Thycon Toshiba UPS Ltd Power distribution equipment APC Aphel BayTech Danaher Eaton IBM Layer Layer Liebert MGE PDI Powersmiths Powerware United Power Meters Autometers BMI Circutor Crompton DataTrax Dent Dranetz Eaton Electro Industries EMON Entes GE IME Kele NK Onicon PML Satec Schneider Siemens SquareD Universal Veris Westinghouse Circuit protection Basler Eaton GE SEL Siemens SquareD Utility Relay Co Transfer switches APC ASCO BayTech Chloride Cyberex Danaher Eaton EATON CORPORATION 33
34 GE Kohler L3 STS Layer Liebert MGE Onan PDI Russelectric Spectrum TwinSource United Power Drives ABB Danfoss Eaton Eurotherm Saftronics Telemecanique Yaskawa HVAC Airflow APC Compu-Aire Data Aire Dectron Hiross Liebert Nortec Opengate Stulz Environmental monitoring Eaton Powerware APC Caron Chromalox IT Watchdogs Lighthouse Nalco PointSix Sensa SquareD Boltek Davis Global Atmos Rugid Computer Weather Protocols APC ASCII BACnet BACnet WS+ BCM CMI ASCII INCOM Liebert Info Modbus RTU Modbus TCP Modbus3 OPC Server QCPort Shut SNMP UPSCode II XCP BMS Alber BTech CellWatch JCI Phoenix Powershield Generators Basler Caterpillar FW Murphy Generac Katolight Kohler Onan Synergy Chillers APC Carrier Liebert McQuay Multistack Rittal York 34 EATON CORPORATION Foreseer Services Product Application Guide
35 Security and safety Cerberus Fike Fire Generic Fire Kidde-Fenwal Fuel monitoring EarthSafe EBW JCH Omntec Phoenix Pneumercator Preferred Inst Veeder-Root PLC s Allen-Bradley GE JCI Modicon TWIDO Leak detection AquaLeak Liebert PermAlert RLE Tracetek Lighting control Other 13.0 Typical options & accessories list Power Xpert Reporting Offers the big picture every time. Power Xpert offers a convenient report boils down the numbers and events to intuitive graphs and charts. The report allocates energy costs, compares consumption, monitors branch circuits, keeps capacity in check and summarizes your power quality. And you get it automatically delivered via at intervals that you define. Manager of Managers (MOM) Provides a powerful means to integrate data from multiple locations where each location is running its own Foreseer Class server. This unique feature provides a scalable system where the total number of integrated points on the centralized MOM server can be as large as 256,000 points. Secure Web Server (https) Provides an encrypted means to protect all data that is viewed via a standard Web browser on the Internet or intranet. Utilizing the OpenSSL package from the Internet, Foreseer Class software is able to provide 128 bit encryption between the Foreseer Class Web server and the Web browser client. Both registered certificates from a 3rd party provider or self-signed certificates are allowed to be used with this option. Software Classes There are four Software Classes: Foreseer C-Class Server Software (up to 15,000 channels) Foreseer M-Class Server Software (up to 25,000 channels) Foreseer R-Class Server Software (up to 100,000 channels) Foreseer S-Class Server Software (up to 256,000 channels) Redundancy Safeguards valuable information. The inclusion of one or more extra Foreseer Class servers provides the highest levels of system reliability. In the event that one Foreseer Class server fails, the remaining servers carry the load of the power monitoring system. Data Acquisition Engine (DAE) Designed specifically for geographically or physically removed sites where local IT expertise may not exist. The Data Acquisition Engine automatically collects and sends data from critical infrastructure devices, and communicates that data back to the Foreseer Class server. Using local processing and the shared bandwidth of an IP network, the DAE reduces the cost required to transmit data to the central server. The DAE also continues to operate independently and generate alarms even if the connection to the central server is unavailable, increasing the overall availability of the management system. Data Acquisition Terminal (DAT) Easily integrates monitored equipment and sensors located in small, networked remote sites. The DAT employs standard Modbus communications to relay information to either a Foreseer Class server or a Data Acquisition Engine over a TCP/ IP network. Data is packaged in sequential Modbus registers to enable optimum scan times without impacting network bandwidth. Services Hardware: Data Acquisition Engine (DAE) Data Acquisition Terminal (DAT) Server CPU EATON CORPORATION 35
36 Software: Foreseer Software Classes Foreseer C-Class Server Software (up to 15,000 channels) Foreseer M-Class Server Software (up to 25,000 channels) Foreseer R-Class Server Software (up to 100,000 channels) Foreseer S-Class Server Software (up to 256,000 channels) Manager of Managers (MOM) Secure Web Server Redundant Server Power Xpert Reporting Branch Circuit Monitoring Report Capacity Report Data Center Efficiency Report Energy Cost Allocation Report Energy Summary Report Event Summary Report Greenhouse Gas Report Joint Commission Report Power Quality Report Utilities Report Upgrades Foreseer Class-C Software Upgrade to Class-M Foreseer Class-C Software Upgrade to Class-R Foreseer Class-C Software Upgrade to Class-S Foreseer Class-M Redundant SQL Support Upgrade Foreseer Class-M Software Upgrade to Class-R Foreseer Class-M Software Upgrade to Class-S Foreseer Class-R Software Upgrade to Class-S Foreseer System Upgrade v. 4 x to v. 5.x - wo/ Contract Foreseer System Upgrade v. 4.x to v. 5.x - w/ Contract Foreseer System Upgrade v. 2.x to v. 5.x - wo/ Contract Foreseer System Upgrade v. 2.x to v. 5.x - w/ Contract 14.0 Software functionality list 14.1 Foreseer Server functions Data acquisition and storage An extensive vendor independent device driver library of over 800 devices. Historical data to support proactive equipment management. All analog readings are stored in the database every minute and digital points are stored on a change of state. User defined channels Powerful, real time, feature that enables the end user to apply any mathematical or logical equation to a combination of channels or data to represent virtual information about their facility or environment. Message management channel configuration Used to assign channels to Alarm Notification call lists. Device and channel properties Allows customization of alarm thresholds, alarm messages, data scaling etc Foreseer Webviews functions Facility/enterprise overview and management A Virtual site or enterprise is created that represents the actual site location and floor plan, navigation is through a simple point and click drill down paradigm. Equipment views show the specific device, current status and data readings. Color utilization makes it easy to determine current state of each site, device or data point. Channel properties With the proper authorization allows customization of alarm thresholds, alarm messages, data scaling etc. Standard Webviews Semi-custom dashboard displays an overview of the facility equipment based on customer selection of Power, Environmental, Life-Safety and Conservation objects. Includes items and calculations for DcIE/PUE, Quality of Power based NERC standards and aggregation of quantities of like equipment. Alarm management The user-interface uses a stop light color scheme (green, yellow, and red) for easy identification of alarm conditions. Each analog channel is measured against four configurable alarm limits (hi-hi, hi, lo and lo-lo). Green indicates normal state, yellow indicates cautionary level alarm, and red indicates a critical level alarm. Operator alarm response instructions are configurable for each alarm limit of every data point. An alarm summary screen can be accessible with a mouse click from any level of the system software. These alarms can be listed by priority, time of occurrence, and type. Each Client has the capability to filter data point alarms, so that individual users can view specific alarms. Data analysis High performance trend analysis and forecasting tools to assess equipment performance through cause analysis, impact analysis, capacity planning, preventative maintenance assessments and trending. Automatic statistical analysis Min, Max, Mean, Range, Standard Deviation and Trend. Projection graph doubles the x-axis of the graph to project the trend into the future. Reports Diagnostic System Reports System Configuration Reports Notes Reports. All alarms are automatically logged to an alarm history report. This report is formatted in 1, 7 and 30 day time periods and display data point in alarm, level, time of occurrence, acknowledgement and rearm. Advanced reports with PXR 36 EATON CORPORATION Foreseer Services Product Application Guide
37 14.3 Message management functions , SNMP traps or paging of alarm events Automatic notification escalation 14.4 Advanced applications functions Custom dashboards Risk Analysis Dashboard Based on current conditions what is the risk your Data Center is experiencing? Power Outage Dashboard A single overview to monitor/manage through a power outage. Power Capacity Dashboard - Track power capacity in real time in an electrical block diagram of your electrical system. Can include items such as carbon footprint and monthly energy usage Maintenance manager The Maintenance Scheduler (MS) is an option within the Foreseer system that allows devices to be disarmed based upon weekly or periodic maintenance schedules. This prevents the alarms that would accompany a device p.m. but at the same time allows for monitoring of the channel. The device is placed upon a predetermined schedule that will disarm that device and the rearm it again at a later predetermined time AC control The Foreseer CRAC interface offers comprehensive monitoring and optional lead/lag control for Data Aire, Liebert, and Airflow air conditioning units. Lead/lag control and scheduling is viewable from Webviews and is controllable with the proper user authority Energy cost allocation Electrical cost has always been a significant part of the operating expense for any business. With the electricity costs increasing every year, tracking usage by individual circuit has become part of the energy management strategy of many companies. Foreseer offers design methods for monitoring and allocating electrical cost to the individual users of a department, device, branch circuit, or even an individual, below is an example. The application totalizes kilowatts per department based on a fixed voltage parameter, total current from a series of breakers assigned to each department and power factor from an upstream device. Each department s kilowatt usage is integrated into kilowatt hours which are saved on a monthly basis. Total kilowatts are also calculated for air conditioning the environment which is then integrated into kilowatt hours and saved on a monthly basis. Each department s percentage of the total kilowatt usage is then calculated. This percentage is then used to assess a portion of the energy used for air conditioning. This results in a department s total allocation for energy on a monthly basis Capacity assessment Foreseer supports informative information on power capacity and power density. Making cogent understanding of power issues, an easy process. This information can show individual capacity of equipment, or a system. With higher density of communications and IT equipment being placed into smaller areas, power density has become a critical measurement. Foreseer can display power density by device or power density for an entire area How to get started with your project 15.1 Foreseer Services hotline To learn how Foreseer Services can enhance the reliability and value of your power distribution, environmental, safety and security systems, or to see a live, online demo, visit our Web site at call your local Eaton representative or our Foreseer Services hotline at , option 3. EATON CORPORATION 37
38 Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH United States 877-ETN-CARE ( ) Eaton Corporation All Rights Reserved Printed in USA AP E / TN January 2011 Eaton, Foreseer and Power Xpert are registered trademarks of Eaton Corporation. All other trademarks are property of their respective owners.
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
Comprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara framework to provide full convergence of
Comprehensive Data Center Energy Management Solutions
FROM INSIGHT TO EFFICIENCY: Comprehensive Data Center Energy Management Solutions Since 1995, facility managers and BAS professionals have relied on the Niagara Framework to provide full convergence of
The necessary convergence of IT and Facilities
The necessary convergence of IT and Facilities Bringing the two groups together under one unified process By Dr. Kenneth Uhlman Director of Data Center Business Development Eaton Corporation Abstract Many
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
scalable data centre energy management solution
scalable data centre energy management solution scalable data centre energy management solution EcoMeasure - Scalable Data Centre Energy Management & Efficiency Measurement Solution by Workspace Technology
How green is your data center?
Siemens Answers: Sustainable Future How green is your data center? Istanbul June 01, 2010 Agenda 1 Solution 2 Siemens Data Center Approach 2 Designing with multiple power density zones can reduce energy
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
Server Technology, Inc.
Server Technology, Inc. Cabinet Power Monitoring, Management & Control Within the Data Center White Paper STI-100-011 2010-Sept-27 by Calvin Nicholson, Senior Director Software and Strategic Alliances,
Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions
Data Centre Solutions... energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration
Revolutionizing Data Center Infrastructure Management
Infrastructure Management & Monitoring for Business-Critical Continuity TM Revolutionizing Data Center Infrastructure Management The Trellis Platform A Real-Time Solution to Continuous Performance Improvement
DATA CENTER PHYSICAL INFRASTRUCTURE
Is your datacenter running with maximum performance? Datacenter managers have been challenged to maintain or increase availability, maximize efficiency, and optimize the use of existing capacity. However,
Classification of Data Center Infrastructure Management (DCIM) Tools
Classification of Infrastructure Management (DCIM) Tools White Paper 104 Revision 3 by Kevin Brown Dennis Bouley > Executive summary Data centers today lack a formal system for classifying infrastructure
Data Centers: Definitions, Concepts and Concerns
Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data
Case study: End-to-end data centre infrastructure management
Case study: End-to-end data centre infrastructure management Situation: A leading public sector organisation suspected that their air conditioning units were not cooling the data centre efficiently. Consequently,
Improving Data Centers Energy Reliability & Efficiency. December 2015
Improving Data Centers Energy Reliability & Efficiency December 2015 Background The challenges Alternative solutions SATEC approach Advantages Cases Summary Data Centers Energy Challenges Worldwide Data
Big Data Approaches For Retail Facility Management
Big Data Approaches For Retail Facility Management Quest For Facility Cost Savings 1. Proliferation of Facility Controls Electromechanical To Electronic Control Smart Algorithms And Control Schemes Modems
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity
Liebert GXT MT+ CX UPS, 1000VA - 3000VA Intelligent, Reliable UPS Protection AC Power for Business-Critical Continuity Liebert GXT MT+ CX UPS, 1000VA -3000VA Intelligent, Reliable UPS Protection Liebert
Model Manage Monitor Maximize your Data Center
NetZoomDC is the most feature rich, fully-scalable, enterprise Data Center Infrastructure Management (DCIM) software application. It enables data center professionals to Model, Manage, Monitor and Maximize
Whitepaper from WebNMS M2M. Unified DCIM: Achieving Data Centre Efficiency Beyond IT
Whitepaper from WebNMS M2M Unified DCIM: Achieving Data Centre Efficiency Beyond IT Today s data centers are not just a factory that houses storage systems and stores bytes; they enable to gain competitive
Data Center Infrastructure Management: How to Optimize Data Center Operations
Data Center Infrastructure Management: How to Optimize Data Center Operations Khaled Nassoura, PE [email protected] General Manager Raritan, Inc. Question of the Day Question: Would any CFO run
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
Types of Electrical Meters in Data Centers
Types of Electrical Meters in Data Centers White Paper 172 Revision 1 by David Kidd and Wendy Torell > Executive summary There are several different types of meters that can be designed into a data center,
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring
How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring Brian Rehnke e-pdu Business Development Manager November, 2011 The Problems Energy Usage in most data centers
Data Center Facility Basics
Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern
Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria
Tier 3+ 1 Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria Abstract: Schoolcraft College is constructing a High Availability (HA) Data Center
Power Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
Classification of Data Center Operations Technology (OT) Management Tools
Classification of Data Center Operations Technology (OT) Management Tools White Paper 104 Revision 0 by Kevin Brown Dennis Bouley > Executive summary Data centers today lack a formal system for classifying
Energy Management Services
February, 2012 Energy Management Services Data centers & IT environments are often critical to today s businesses, directly affecting operations and profitability. General & Mechanical Services has the
Improve competiveness of IDC and enterprise data centers with DCIM
Improve competiveness of IDC and enterprise data centers with DCIM This paper studies the implementation of modern DCIM systems for data centers to improve operational competitiveness with ATEN's DCIM
Capacity Planning in the Modern Datacenter
in the Modern Datacenter SERVER TECHNOLOGY - INDUSTRY BRIEF -001 July 2015 Executive Overview Today s datacenter managers oversee more infrastructure than ever, with an exponential increase in complexity
AUTOMSOFT and POWER ANALYTICS - Data Center White Space Management Realized
Executive Summary Power Analytics has been a leading edge provider of analytical software for the Data Center market and related industries for over six years. In that time, Power Analytics has been involved
About Geist. geistglobal.com
About Geist Geist designs and manufactures industry leading technology and software for powering, monitoring, cooling and managing critical data center infrastructure. We produce affordable, quality products
Monitoring the Computer Room s Physical Environment A white paper from Sensaphone, Inc.
Monitoring the Computer Room s Physical Environment A white paper from Sensaphone, Inc. Introduction Nearly all small- and medium-sized businesses rely on a computer network to maintain operations, communicate
RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE
RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE Highly efficient solutions for power distribution, management and monitoring POWER DISTRIBUTION WIRE-FREE MONITORING LEAK DETECTION Daxten provides comprehensive
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
Essential NCPI Management Requirements for Next Generation Data Centers
Essential NCPI Requirements for Next Generation Data Centers By Ted Ives White Paper #14 1 Executive Summary The management of physical infrastructure in data centers can no longer be considered independently
Data Center Commissioning: What you need to know
Data Center Commissioning: What you need to know Course # CXENERGY1511 AIA Provider # 50111116 AABC Commissioning Group CxEnergy Conference Henderson, NV April 30, 2015 Presented by: Judson H. Adams, P.E.,
Calculating Total Power Requirements for Data Centers
Calculating Total Power Requirements for Data Centers By Richard Sawyer White Paper #3 Executive Summary Part of data center planning and design is to align the power and cooling requirements of the IT
Increasing Data Center Resilience While Lowering PUE
Increasing Data Center Resilience While Lowering PUE Nandini Mouli, Ph.D. President/Founder esai LLC [email protected] www.esai.technology Introduction esai LLC esai LLC: Is a Disadvantaged woman-owned
Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy
Data Center Solutions Packet Power for Data Centers Packet Power provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility
Data Center Infrastructure Management: ERP for the Data Center Manager
Data Center Infrastructure Management: ERP for the Data Center Manager 1 2 Topics What s DCIM & the ERP Analogy Why DCIM How DCIM Works How DCIM Helps 3 DCIM by Definition DCIM is a system that collects
Packet Power. Data Center Solutions. Packet Power. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution
Data Center Solutions for Data Centers provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility operations. Gain
Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications
W H I T E P A P E R Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications Executive Summary One of the fundamental decisions in the design of data centers, server rooms
Overview of Green Energy Strategies and Techniques for Modern Data Centers
Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.
Metrics for Data Centre Efficiency
Technology Paper 004 Metrics for Data Centre Efficiency Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile: 0121 354
Network Router Monitoring & Management Services
Network Router Monitoring & Management Services Get different parameters of routers monitored and managed, and protect your business from planned and unplanned downtime. SERVICE DEFINITION: NETWORK ROUTER
StruxureWare TM Data Center Expert
StruxureWare TM Data Center Expert Infrastructure management from rack to row to room to building Deploy in minutes, manage from anywhere, analyze instantly, integrate with other management systems. End
Alternative data center power
Alternative data center power A quantitative TCO comparison of 400V AC and 600V AC power systems Abstract Power efficiency has become a critical focus for IT and facilities managers as they struggle to
Power & Environmental Monitoring
Data Centre Monitoring Made Easy Power & Environmental Monitoring Features & Benefits Packet Power provides the easiest, most cost effective way to capture detailed power and temperature information for
Enterprise Remote Monitoring
Enterprise Remote Monitoring Alarm Management, Predictive Maintenance, Advanced Network Security Services For Business-Critical Continuity Can You Really Afford Not To Know? Loss of productivity and the
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
Eaton epdu. Intelligent and flexible power distribution
Eaton epdu Intelligent and flexible power distribution Introduction and overview With today s changing technology, increasing power demands and the need for reliability, data centre professionals require
Server Technology, Inc.
Server Technology, Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2009-April-07 Headquarters Server Technology, Inc. 1040 Sandhill
Data center management suite. Providing optimal control and efficiency to data center management. www.siemens.com/datacenters
Data center management suite Providing optimal control and efficiency to data center management www.siemens.com/datacenters Streamline operations with Siemens suite of integrated management tools You work
Energy Management Solutions
Energy Management Solutions Introducing the world s most innovative intelligent Power Distribution Units (ipdus) designed to simplify rack energy and environmental management of your data center. Enlogic
Energy Savings in the Data Center Starts with Power Monitoring
Energy Savings in the Data Center Starts with Power Monitoring As global competition intensifies, companies are increasingly turning to technology to help turn mountains of data into a competitive edge.
Tk20 Network Infrastructure
Tk20 Network Infrastructure Tk20 Network Infrastructure Table of Contents Overview... 4 Physical Layout... 4 Air Conditioning:... 4 Backup Power:... 4 Personnel Security:... 4 Fire Prevention and Suppression:...
Application Note: Monitoring Branch Circuit Loads in Critical Facilities
Application Note: Monitoring Branch Circuit Loads in Critical Facilities Description of application: The AcquiSuite data acquisition server (DAS) from Obvius is used to monitor the electrical loads and
How To Use Rittal'S Rizone
RiZone Data Centre Infrastructure Management Enclosures Power Distribution Climate Control IT INFRASTRUcTURe SOFTWARE & SERVICEs RiZone Data Centre Infrastructure Management What can the RiZone Data Centre
Power to the adaptable data center
Business Unit Manager, Data Center Solutions, Eaton s electrical group IT managers have more options than ever to tailor the power infrastructure to their unique data center and business requirements.
Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date
Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理 1 Agenda 1 2 3 相 UPS 總 覽 Introduction & Overview of 3 Phase UPS 理 解 客 戶 最 大 的 考 量 點 Understanding Top Customer Concerns 3 Galaxy VM 關 鍵 技 術 創
The Trellis Dynamic Infrastructure Optimization Platform
Infrastructure Management & Monitoring for Business-Critical Continuity TM The Trellis Dynamic Infrastructure Optimization Platform Delivering Confidence through Connection TM Is Your Data Center Operating
Re Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
You were seeking a protocol translator. Eaton delivered a vital data flow processor.
You were seeking a protocol translator. Eaton delivered a vital data flow processor. Your power system is a critical, integral part your organization s technological infrastructure. Ensuring availability,
This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.
This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits. DCD, DCOM, DCE DESIGN IMPLEMENTATION BEST PRACTICE OPERATION & MANAGEMENT DATA
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System MODEL NUMBER: HTR05-1U Description Tripp Lite's HTR05-1U AVR Series intelligent, Automatic Voltage Regulated
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
CUSTOMER EXPERIENCE CENTER
v CUSTOMER EXPERIENCE CENTER ABOUT THE CUSTOMER EXPERIENCE CENTER MAKE YOUR DATA CENTER AS DYNAMIC AS YOUR BUSINESS Emerson Network Power continuously strives to provide the best solutions by working collaboratively
Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ
Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ 2011 Raritan Inc. Overview Data center managers are faced with increasingly challenging demands: supplying additional computing
Paralleling Switchgear
Paralleling Switchgear By Maurice D Mello, P.Eng. Systems Engineer, GE Consumer & Industrial, Canada What is Paralleling? Paralleling is the operation in which multiple power sources, usually two or more
System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution
System integration oriented data center planning In terms of ATEN's eco Sensors DCIM solution 1. Introduction The reliability of an enterprise data center servicing either external or internal clients
Mixing Sodium and Lead Battery Technologies in Telecom Applications
Mixing Sodium and Lead Battery Technologies in Telecom Applications Paul Smith Shanon Kolasienski Technical Marketing Manager Application Engineer GE Critical Power GE Energy Storage Plano, TX 75074 Schenectady,
Australian Government Data Centre Strategy 2010-2025
Australian Government Data Centre Strategy 2010-2025 Better Practice Guide: Data Centre Power June 2013 17/06/2013 4:12 PM 17/06/2013 4:12 PM Contents Contents 2 1. Introduction 3 Scope 3 Policy Framework
Power Management. Raritan Description. http://www.raritan.com/products/power-management/
Raritan Description Raritan is a proven innovator of power management, infrastructure management, KVM and serial solutions for data centers of all sizes. In more than 50,000 locations worldwide, our hardware
CenterMind P+ Solution for efficient power management
CenterMind P+ Solution for efficient power management Overview Over last decade DC become significant power consuming facilities Information Technology Equipment (ITE) continue to increase computing capabilities
Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES
UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)
Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6
Contents Introduction 1 Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5 Initial Configuration Requirements 6 Overview 6 Setup Wizard 7 Status, Alarm,
Statement Of Work. Data Center Thermography Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary
Statement Of Work Professional Services Data Center Thermography Assessment Data Center Thermography Assessment Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits
Engineering & Support Services
Engineering & Support Services Expert Project, Engineering & Customer Support Services Providing a range of Engineering and Support Services for:- Mission Critical Environments Data Centres & Server Room
SMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.
AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled
www.aten.com Application Guide Guardian Over the NET Server Room Solution
www.aten.com Guardian Over the NET Server Room Solution Develop a Secure, Stable Server Room For security reasons, more and more companies house all their servers in a secure environment a server room
Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks
Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks White Paper Anil K. Trehan, Vice President, Energy Solutions CommScope, Inc. May 28, 2013 Contents
Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring
Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring A White Paper from the Experts in Business-Critical Continuity Summary The first decade of the 21st century
Reducing operating costs of telecom base stations with remote management
Reducing operating costs of telecom base stations with remote management Whitepaper How remote management can be used to cut operating expenses of existing telecom infrastructure. HMS Industrial Networks
One unbelievable solution for rack-level data center power management. Sentry Power Manager. Solutions for the Data Center Equipment Cabinet
One unbelievable solution for rack-level data center power management. Sentry Power Manager Solutions for the Data Center Equipment Cabinet Sentry Power Manager. The most comprehensive and affordable rack-level
TracKing. A complete web-enabled temperature management system.
TracKing A complete web-enabled temperature management system. Wireless communications for improved asset utilization and fleet efficiency. T hermo King is proud to offer a new mobile communications system
SECTION 16911 WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM
WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM PART 1 GENERAL 01 02 03 04 SCOPE This section describes the metering, communications, and visualization requirements for a modular, scalable Web-based Power