Best Practices for Wire-free Environmental Monitoring in the Data Center



Similar documents
Best Practices for Wire-free Environmental Monitoring in the Data Center

MAXIMIZING YOUR DATA CENTER INFRASTRUCTURE: CENTRALIZED MANAGEMENT AND WIRE-FREE ENVIRONMENTAL MONITORING

Environmental Data Center Management and Monitoring

DCIM Data Center Infrastructure Monitoring

Integrated Wire-Free Solution for Monitoring Power and Environment with RF Code and Sentry Power Manager (SPM)

5 Reasons. Environment Sensors are used in all Modern Data Centers

Element D Services Heating, Ventilating, and Air Conditioning

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Introducing AUDIT- BUDDY

APC APPLICATION NOTE #112

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

Data Center Cooling A guide from: Your partners in UPS Monitoring Systems

Server Room, Data Centre Management and Monitoring Solutions

APC APPLICATION NOTE #92

Advantages of Wire- Free Power Monitoring in the Data Center

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Raised Floor Data Centers Prepared for the Future

Utilizing Temperature Monitoring to Increase Datacenter Cooling Efficiency

How To Run A Data Center Efficiently

The New Data Center Cooling Paradigm The Tiered Approach

In Row Cooling Options for High Density IT Applications

Comprehensive Data Center Energy Management Solutions

How To Improve Energy Efficiency In A Data Center

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Includes customer case study. February 28, 2013

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Managing Data Centre Heat Issues

Comprehensive Data Center Energy Management Solutions

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Managing Cooling Capacity & Redundancy In Data Centers Today

White Paper Rack climate control in data centres

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Managing the Data Center One Rack at a Time

Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning

Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

Airflow Simulation Solves Data Centre Cooling Problem

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Microsoft Technology Center: Philadelphia

Data center upgrade proposal. (phase one)

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Using CFD for optimal thermal management and cooling design in data centers

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

Management and Wireless in the Data Center

Data Centre Testing and Commissioning

Reducing the Annual Cost of a Telecommunications Data Center

White Paper: Server Room Environmental Monitoring

Virtual Data Centre Design A blueprint for success

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Data Center Components Overview

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Data Center Cooling A guide from: Your partners in UPS Monitoring Systems

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Enclosure and Airflow Management Solution

Choosing Close-Coupled IT Cooling Solutions

Measure Server delta- T using AUDIT- BUDDY

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Ammonia Detection System Codes and Design Specifications

EMC PERSPECTIVE Managing Energy Efficiency in the Data Center

Cisco Data Center Facilities Assessment Service

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

JAWAHARLAL NEHRU UNIVERSITY

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Rack Hygiene. Data Center White Paper. Executive Summary

- White Paper - Data Centre Cooling. Best Practice

Data Operations Center Renovation

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

The Pros and Cons of Modular Systems

Relative Sensitivity based Fire Detection Systems used in High Density Computer Rooms with In-Row Air Conditioning Units

Increasing Energ y Efficiency In Data Centers

Impact of Virtualization on Data Center Physical Infrastructure White Paper #27. Tom Brey, IBM Operations Work Group

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

An Introduction to Cold Aisle Containment Systems in the Data Centre

Introducing Tripp Lite s PowerAlert Network Management Software

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.)

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions

Achieving ROI through Automated Physical IT Asset Tracking. White Paper

CenterMind G+ Smart and Proactive Environment Monitoring

SensiNet Rack Sentry Data Center Handbook

Management Strategy for Network Critical Physical Infrastructure

University of St Andrews. Energy Efficient Data Centre Cooling

Virginia Tech. Background. Case Summary. Results

Cabinets 101: Configuring A Network Or Server Cabinet

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Strategies for Deploying Blade Servers in Existing Data Centers

Transcription:

White Paper 11800 Ridge Parkway Broomfiled, CO 80021 1-800-638-2638 http://www.42u.com sales@42u.com Best Practices for Wire-free Environmental Monitoring in the Data Center

Introduction Monitoring for environmental threats in the data center is not a new concept. Since the beginning of modern data centers, the temperature of servers and network equipment has been a constant concern as one of the most threatening environmental conditions. The idea that servers need to be protected from environmental threats and operated only under the right conditions coincided with the explosion of client-server computing. Together, both were the driving factors behind the creation of the modern data center in the late 1980 s and early 1990 s. Since then, the physical construction, physical layout, and implementation of a data center has steadily improved, optimized to accommodate the ever-changing requirements driven by advances in server and storage technology. The methods and mechanisms to monitor for physical threats in the data center have also evolved. In this paper, we will explore wire-free environmental monitoring best practices, one of the newest developments in data center physical threat monitoring. Environmental Threats in the Data Center Before diving into the best practices for monitoring environmental threats with wire-free sensors, let s first review the top physical threats to the data center and impact of these threats. Temperature The first and most important physical threat to the data center is temperature. There are many physical locations in the data center where temperature is critical: Air temperature in the plenum spaces such as raised floors, especially far away from the CRACs Air temperature above the plenum and in front of the racks on cold aisles (i.e., the intake air for the servers in the racks) especially if the racks are fully enclosed (doors front and rear as well as sides) Humidity Humidity is like air temperature in that it can vary throughout the data center, although it typically does not vary as much. It is not uncommon for data center humidity readings to vary with the outdoor humidity conditions. Most modern CRACs (computer room air conditioning unit) have the ability to control (increase or decrease) the humidity in the data center. The danger of low humidity conditions in the data center is threat of electrostatic discharge (ESD), which can damage electrical components. The result of high humidity in the data center is the possibility of condensation. ASHRAE currently recommends a range of 40%-55% for data center humidity. Water or Fluid Leaks Water or fluid leaks in the data center are definitely a concern. The severity of this threat to a data center varies according to construction details, equipment use and water/fluid systems placement. Many systems use fluid or water for cooling from CRACs to water cooled systems to fire suppression systems. The impact to the data center from fluid or water leaks is damage to electronic systems and cabling. Door Position The position of rack doors and room doors is directly related to the physical threats of are air flow/ cooling and access control. Proper and efficient air flow and cooling are constructed around a known or fixed configuration, which incorporates the knowledge that doors to racks and rooms are supposed to be open or closed. Normal open and closing of a door in a short period of time typically does not impact air flow and cooling. However, doors that are propped open for extended periods of time can cause issues. Air temperature inside the IT racks themselves, Page 1

Air Handler or CRAC Failure Understanding, even at the most basic level, the state or health of a CRAC in the data center is essential. Not all CRACs and air handlers have network monitoring and management capabilities, particularly older units and models. However, most CRACs and air handlers (as well as generators) typically do have dry contact monitoring capabilities. Dry Contact is basically a relay that makes or breaks a circuit to indicate a status change or fault with a device. So a CRAC, for example, may have one or more dry contact connection points that may indicate things such as fan status (normal or fault) and compressor status (normal or fault). Proactively monitoring the status of CRAC units, even at a basic dry contact level, can reduce the impact of a failure and increase the amount of time available to respond to the issue. Physical Threat Summary The following is a summary table of the most common physical threats to a data center, their impact and the right sensor to monitor proactively for these threats. Best Practice Sensor Placement An acquaintance of mine who runs the IBM Green Data Center in Austin Texas, uses the following phrase when he communicates how he manages the data center: Intelligent data allow for intelligent decisions. In other words, the more information you have about the conditions in your data center, the better equipped you are to make decisions regarding the optimization, expansion, and utilization of your data center. Environmental monitoring and physical threat sensors provide the infrastructure to collect intelligent data throughout the data center. Now let s look at the best practice methods for sensor placement to proactively monitor for physical threats in the Page 2

data center. Temperature Sensors There is no single answer to what is the ideal placement for temperature sensors in a data center. Multiple factors influence the quantity and location of the temperature sensors needed to properly. These include data center design, load, capacity, percent utilization, and efficiency goals. The classic way of running a data center was to cool the data center regardless of cost and efficiency. With the new green way of thinking and the fact that operational costs of now outweigh the capital costs of a data center, the concept of overcooling has lost favor. Three temperature sensors in the front of every rack, with one mounted about twelve inches from the bottom, one mounted in the middle and one mount about twelve inches from the top of the rack One temperature sensor in the rear of every rack at mid-point of the height of the rack The following illustration shows proper placement of temperature sensors (assuming maximum coverage) in the front of a closed rack. Regardless of the mounting location and quantity For cold aisles and hot aisles the quantity of sensors can vary, depending on your monitoring goals and budget. For closed racks with doors, it is recommended to place the sensor on the inside of the rack door. For open racks without doors, it is a matter of convenient and secure mounting location more than anything else. A good location for open racks is the left or right side of the rack but not interfering with the equipment U space. The following are three best practice recommendations around the placement of temperature sensors: Minimal temperature sensor coverage One temperature sensor in the front of every rack at mid-point of the height of the rack One temperature sensor in the rear of every five racks at mid-point of the height of the rack Typical temperature sensor coverage Two temperature sensors in the front of every rack, with one mounted about sixteen inches from the bottom of the rack and one about sixteen inches from the top of the rack One temperature sensor in the rear of every other rack at mid-point of the height of the rack of temperature sensors used, always mount sensors consistently from rack to rack and row to row. To better understand the environment in the plenum, additional temperature sensors may be placed in plenum spaces such as below raised floors. Maximum temperature sensor coverage Page 3

Humidity Sensors Humidity does not vary as quickly in a data center as temperature. Therefore, fewer humidity sensors are needed. Humidity sensors are typically placed on cold aisles and spaced fairly far apart. The following are three best practice recommendations around the placement of humidity sensors: Minimal humidity sensor coverage One humidity sensor per row placed in the front of a rack in the middle of the row Typical humidity sensor coverage One humidity sensor for every five racks placed in the front of a rack Maximum humidity sensor coverage One humidity sensor for every three racks placed in the front of a rack As with temperature sensors, humidity sensors should always be mounted consistently throughout the data center. Liquid Sensors Liquid or leak sensors should be placed near the potential sources of the liquid. The most common fluid source in the data center is the CRACs. However, more sources may be present in your data center. So it is best to involve the facilities manager who can indentify pipes that may be hidden behind walls as well. Additional sensors may be needed if your data center is in the basement level of building (or even partially below ground level) because of potential water seepage from outside walls. Door Position Sensors At a minimum, door sensors should be placed on all doors that provide access to the data center, even if an access control system is installed. In addition, door sensors may be installed on the front and rear of IT racks. Dry Contact Sensors Any CRAC or air handler not monitored via SNMP should have a dry contact sensor attached. Note that outdoor generators as well as UPS systems usually have dry contact connection points as well. Page 4

Shortcomings of Wired Environmental Monitoring Solutions The traditional wired environmental monitoring systems on the market today typically consist of the following components: Aggregation appliances that install in the IT rack, host the environmental sensors and are accessible via TCP/ IP network Wired sensors that physically connect to aggregation appliances Monitoring software that communicates to aggregation appliances to collect sensor information These traditional wired environmental monitoring solutions are usually deployed in one of two ways. Some solutions require installing an aggregation appliance in each IT rack. Once the aggregation appliance is installed, then the wired sensors must be connected to the appliance and then placed in the appropriate position in the rack. Other solutions dictate installing one aggregation appliance for a row or group of IT racks. In this case, the environmental sensors from each rack are cabled back to the one appliance, which means there are cable connections between racks. Regardless of the deployment approach, wired sensors are required and disciplined cable management practices must be followed during the installation. Page 5

Traditional wired environmental monitoring solutions have a number of drawbacks in light of the newer wire-free solutions. 1. The cost of a wired solution is substantial. Using the assumption that a typical aggregation appliance costs about $800.00 and each environmental sensor costs about $99.00, the following estimates can be made. a. Assuming a 250 rack data center where one aggregation appliance and three sensors are installed in each rack, the total cost would be $274,250.00 or $1,097.00 per rack. b. Assuming a 250 rack data center where one aggregation appliance is installed for every 5 racks and three sensors are installed each rack, the total cost would be $114,250.00 or $457.00 per rack. 2. The entire concept of aggregation appliances that physically connect to sensors is scale limiting and costly. Aggregation appliances have a limited number of ports or connections for external sensors. As more sensors are added to the rack, more aggregation appliances are required. It is important to understand that future expansion is limited to the number of available ports on the aggregation appliances. 3. Aggregation appliances consume valuable rack space. Some aggregation appliances must be installed in a U space, which is extremely valuable real estate in a high density data center. Other aggregation appliances are designed to be installed in zero- U spaces, but these are often fully used by intelligent PDUs in the rear of the rack. Finally, aggregation appliances require power and Ethernet connections. 4. Lastly, the cost to deploy a wired monitoring solution is quite costly. Assuming an hourly rate of $100.00 per hour, 30 minutes to install an aggregation appliance and 15 minutes to install a wired sensor, the following estimates can be made: a. Assuming a 250 rack data center where one aggregation appliance and three sensors are installed in each rack, the total time to install the solution= 312 person hours or 39 person days. The total cost would be $31,200.00. b. Assuming a 250 rack data center where one aggregation appliance is installed for every 5 racks and three sensors are installed each rack, the total time to install the solution would be 212 person hours or 26 person days. The total cost would be $21,200.00. Advantages of Wire-free Environmental Monitoring Solutions The new wire-free environmental monitoring solutions on the market today are typically comprised of the following components: Battery-powered small wire-free sensors Radio frequency (RF) receivers that collect data from the wire-free sensors and are accessible on the TCP/IP network Monitoring software that communicates to receivers to collect information from wire-free sensors Not all wire-free sensor solutions are the same. It is important that a wire-free sensor solution has the following characteristics: Small and inexpensive wire-free sensors, NOT small boxes with wired external sensors Minimum 3 years battery life on all sensors, with replaceable batteries Long range, wire-free communications between sensors and RF receivers that must work inside racks with doors and sides Simple setup and configuration that does not require special radio communications skills Wire-free sensor solutions are typically deployed installing Page 6

one or more RF receivers in the data center. These RF receivers require power and an Ethernet connection. RF receivers should easily cover 2000 square feet at a minimum. The wire-free sensors themselves should be very small and easy to install inside and outside the IT rack. Wire-free sensors should be installed by simply sticking them to the rack using adhesive. This makes deployment time extremely fast. The most important item to note is that there are no wires to purchase, install and manage. Wire-free environmental monitoring solutions have a number of advantages over the traditional wired approach. 1. They typically cost much less than wired solutions. When using wire-free solutions, sensors usually cost between $40.00 and $90.00. The RF receivers usually cost between $1,000.00 and $1,300.00. The best wire-free monitoring solution RF receivers should easily handle 2,000-4,000 sensors and cover thousands of square feet of data center. Using the assumption that a RF receiver costs about $1,000.00 and each environmental sensor costs about $79.00, the following estimates can be made. a. Assuming a 250 rack data center where one RF receiver covers about 20 racks (conservative RF coverage) and three sensors are installed in each rack, the total cost would be $71,750.00 or $287.00 per rack. b. Assuming a 250 rack data center where one RF receiver covers about 40 racks (typical RF coverage) and three sensors are installed in each rack, the total cost would be $65,500.00 or $262.00 per rack. 2. There are no wires to install and manage with wire-free solutions. 3. Wire-free monitoring solutions do not consume any valuable rack space because the RF readers are typically Page 7

mounted to the data center ceiling. 4. Properly designed wire-free solutions have a very high sensor- to-rf receiver ratio that allows for massive scalability. New sensors can be added without worrying about wiring connections and cabling restrictions. 5. In most wire-free sensor solutions, more than one RF receiver can receive the RF broadcast from each tag. Having multiple RF receivers with the same coverage zone eliminates the single point of failure of aggregation appliances. 6. Lastly, the cost to deploy a wire-free environmental monitoring solution is substantially less than a traditional wired solution. Assuming an hourly rate of $100.00 per hour, 30 minutes to install a RF receiver and 5 minutes to install a wire-free sensor, the following estimates can be made. a. Assuming a 250 rack data center where one RF receiver covers about 20 racks (conservative RF coverage) and three sensors are installed in each rack the total time to install the solution=68 person hours or 8.5 person days. The total cost would be $6,800.00. b. Assuming a 250 rack data center where one RF receiver covers about 40 racks (typical RF coverage) and three sensors are installed in each rack, the total time to install the solution=65 person hours or 8.2 person days. The total cost would be $6,500.00. Environmental Monitoring Software the Must Have Capabilities The monitoring software provided as part of the environmental monitoring solution is just as important as the sensors themselves. The monitoring software turns thousands of data points into valuable and usable information. The following are characteristics for environmental monitoring software: The software must be very scalable and must be able to handle tens of thousands of sensors The sensor location is the primary attributes with sensor readings the secondary attribute. The data are useless without knowing the exact location of each sensor Centralized policy based thresholds provide simplified management and enable mass management Multiple notification methods for threshold breaches such as SNMP, email, HTTP Post, are a must The software must be an open system that allows easy integration with enterprise class monitoring solutions in the data center such as Tivoli, HP, CA and building management systems. Conclusion Wired environmental monitoring solutions are the old and expensive way to monitor your data center. Wirefree environmental monitoring offers the following key advantages: Has a lower cost Is cheaper and easier to deploy Saves critical rack space Provides massive scalability and future expansion If you are considering an environmental monitoring solution for your data center, don t make the mistake of doing it the classic way. Green initiatives depend on instant and continuous visibility into data center hot and cold spots. Having the right information at the right time is more important than ever. A wire-free approach ensures you have both. 9229 Waterford Centre Blvd. s Suite 500 Austin, TX 78758 Tel: 512.439.2200 s Fax: 512.439.2199 sales@rfcode.com s http://www.rfcode.com Copyright 2012 RF Code, Inc. All Rights Reserved. RF Code and the RF Code logo are either registered trademarks or trademarks of RF Code Incorporated in the United States and/or other countries. All other trademarks are the property of their respective owners.