CSA Certified File # 1637485 (series S05, S06 & S02)



Similar documents
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Pressure Switch for gas and air

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

G670 Intermittent Pilot Ignition Controls

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Oil and Coolant Circulating Heating System. Model - OCSM

Your safety and the safety of others are very important.

Manual for Fire Suppression & Methane Detection System

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Advantium 2 Plus Alarm

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

MCR1900 Media Converter 19-Slot Chassis

Y7230A CO 2 Alarm System

Centro-Matic Automatic Lubrication Systems System Controls

Installation Instructions for Alarm Module Kit A043F059

DC400 Dispensing Cutoff System

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

! WARNING. Before using product, read and understand instructions.

Thermo Top - Troubleshooting Tree

Duct Humidity Transmitter

Part I - Installation

Leak Detection System

Operator: Save these instructions for future use!

User s Manual Before using the inverter, you need to read and save the safety instructions.

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Firewall. Propane flame projector Safety instructions and operating manual

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Addendum to the Operating Instructions

Model Description / Applications. Intermittent Pilot Gas Ignition Control

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Factory owners must ensure the boiler is:

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

, User s Manual

orlando OWNER S MANUAL

1998½-2007 Dodge Ram 5.9L Cummins

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Technical Information

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Veri-Flame Single Burner Monitoring System

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

OPL BASIC. Dosing System for Professional Laundry machines. Contents

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Technical Guide 08/15/14

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

DC Series Digital Conversion Alarm Operator s Manual

Pressure switches for gas and air Pressure sensors

Know-how makes the difference. Electrical Actuators

Online UPS. PowerWalker VFI 1000R/1U

i ChatterBox! Motorcycle Security

BERMAD Fire Protection

ACS-30-EU-EMDR-10-MOD

Technical Information

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

E2 Series Electric Furnaces

TS93 EMR T/PT/TDE. Surface applied door closer

Line to Refrigerator Ice/Water Dispenser

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

TorqPlus TM Electric Valve Actuators and Controls

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

VOYAGER 570G. 744A Sprayer Control

Safety Manual BT50(T) Safety relay / Expansion relay

Operating Instructions Drill rig DRU160

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

BroadBand PowerShield. User Manual

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Utility Distribution Systems

Three-phase monitoring relay CM-PFE

12-Volt 10-Amp Regulated Power Supply

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Transcription:

VPS 504 S06, S05 & S02 Valve Proving System Installation Instructions USA CDN Table of Contents Table of Contents... Page 1 Approvals... Page 1 Attention... Page 1 Specification... Page 2 Mounting Positions... Page 3 Mounting VPS 504 to DMV Shutoff Valve... Page 4 Wiring... Page 4 Wiring VPS as proof of closure... Page 5 Operation... Page 5 Leak Detection Limit for each Valve... Page 6 Maintenance & Testing... Page 6 Accessories & Replacement... Page 7 Approvals Attention UL Recognized File # MN 17004 (S06 only) CSA Certified File # 1637485 (series S05, S06 & S02) FM Approved File # J.I. 3004006 (7411) (S06 only) New York City: File # MEA 51-05-E (S06 only) Commonwealth of Massachusetts Approved Product Approval code G1-1107-35 1 9 Explanation of symbols 1, 2, 3... = Action = Instruction The installation and maintenance of this product must be done under the supervision of an experienced and trained specialist. Never perform work if gas pressure or power is applied, or in the presence of an open flame. Please read the instruction before installing or operating. Keep the instruction in a safe place. You find the instruction also at www. dungs.com If these instructions are not heeded, the result may be personal injury or damage to property. Any adjustment and applicationspecific adjustment values must be made in accordance with the equipment manufacturers instructions. [V] [A] [Hz] [VA] Safety first O.K. IFGC CSA UL ANSI NFPA Check the ratings in the specifications to verify that they are suitable for your application. On completion of work on the valve proving system, perform a leakage and function test. This product is intended for installations covered by, but not limited to, the following codes and standards: NFPA 86, NFPA 85, Swiss Re (formerly IRI) or CSA B149.3.

Specification VPS The Valve Proving System VPS 504 checks that both safety shutoff valves in a Dual Modular Valve (DMV) are closed before either a system start-up or after shutdown when wired and interlocked with a sutiable flame monitoring relay. The VPS 504 will halt the start-up sequence to a burner if it detects an open or damaged safety shutoff valve, thus preventing ignition under potentially dangerous conditions. [PSI] Max. Operating Pressure (MOP) 7 PSI (500 mbar) Max. Body Pressure 15 PSI (1000 mbar) F +140 +5 0 Ambient / Fluid Temperature +5 F to +140 F (-15 C to +60 C) [V] [A] [Hz] [VA] Electrical Input Ratings 120 VAC / 60 Hz for S06 Series and 24 VDC for S05 and S02 Series Power Rating (consumption) Valve proving 60 VA In operation 17 VA Switch Output Ratings S06 Series: RUN (T5) 4 A and ALARM (T3) 1 A @ 120 VAC S05 and S02 Series: RUN (TB) 4 A and ALARM (TS) 1 A @ 24 VDC Gas Gases Dry, natural gas, air and other inert gases. NOT suitable for butane or any gas mixture containing 60 % or more of butane. A dry gas has a dew point lower than +15 F and its relative humidity is less than 60 %. Materials in Contact with Gas Housing: Aluminum Seals: NBR-based rubber NEMA Enclosure Rating NEMA Type 12 IEC 529 / NEMA 250 Operating Time 100 % duty cycle; Maximum 20 test cycles per hour Release Period (time to get a RUN or ALARM) 10 sec. for test volume < 0.05 ft 3 >10 sec. (max. 26 s) for test volume > 0.05 ft 3 Detection Limits of Natural Gas (each valve) Less than 1.76 ft 3 /h (0.2-1.0 ft 3 /h through both valves) Test Volume Less than 0.14 ft 3 Electrical Connection Screw terminals with 1/2 NPT conduit connection 2 9

Mounting Positions Location for DMV 7xx series The VPS 504 is to be mounted directly to either side of the DMV to ports 1 and 2. 2 1 3 1 Mounting Holes Location for DMV 525 Series The VPS 504 is to be mounted directly to either side of the DMV to ports 2 and 3. Mounting Holes 3 9 Location for DMV 5xxx Flanged Series The VPS 504 is to be mounted directly to either side of the DMV to ports 2 and 3. Mounting Holes

Mounting VPS 504 to DMV Shutoff Valve Recommended Mounting Procedure 1. Shut off the gas supply and disconnect all power to the DMV and the VPS 504 to prevent shock and equipment damage. 2. Verify the 10.5 x 2.25 mm O-rings are fitted into the grooves on the back of the VPS 504. 3. Verify that the O-rings are clean and in good condition. 4. Remove the G 1/8 plugs from port 1 and port 2 of the valve with a 3 mm hex key wrench. 5. Verify that the surface is clean and in good condition. Clean if necessary. 6. Use the M 4 x 15 mm self tapping hex head screws supplied to mount the VPS 504 to the DMV valve body. DO NOT Exceed 22 lb-in of Torque. 7. Verify that the O-rings are located in the grooves form a complete leak test to verify that no leakage occurs around the O-rings. Do not adjust or remove any screws or bolts which are sealed with a Red or Blue colored compound. Doing so will void all approvals and warranties. Wiring Wiring Procedure 1. Use 14 or 16 gauge wire rated for 95 C (200 F). 2. Disconnect all power to the VPS 504 before beginning the wiring to prevent electrical shock and equipment damage. 3. Remove the black cap on top of the VPS 504. 4. Loosen the screw which secures the gray cover and remove. 5. Attach 1/2 NPT conduit to the black conduit adapter. 6. Route the wires through the conduit connector. 7. Install a conduit plug at some point in the conduit run between the VPS and closest panel that contains switching contacts or other sparking devices (see NFPA 86 requirements about potential risks of gas leaking down conduit). 8. Connect the wiring to the appropriate screw terminals on the terminal strip. 9. Replace the gray cover, the screw, and the black cap. 10. A typical wiring diagram for operating the VPS 504 on burner start-up only is shown below. VPS 504 Internal Wiring and Terminals series 06 and S05 + S02 internal wiring 120 VAC Terminals 24 VDC Terminals I max Run Terminal: 4 A Alarm Terminal: 1 A leak detected or valve open no leak detected Output Input ALARM 3 RUN 5 L 1 6 N 7 8 S (+) B (+) + V3 P Operating Voltage VPS 504 S06 = 120 VAC/60 Hz VPS 504 S05 = 24 VDC VPS 504 S02 = 24 VDC Do not wire the VDK RUN terminal to directly power the safety shutoff valves. The safety shutoff valves should always be under direct command to the flame safeguard. Frequency converters or frequency drive motors with insufficient shielding can cause faults in the VPS 504 as the result of transients. Verify that the equipment is provided with sufficient shielding. Operating voltage for the S06 series is 120 VAC 60 Hz. NOT suitable for 50 Hz. All wiring must comply with local electrical codes, ordinances and regulations. 4 9

Wiring VPS as proof of closure VPS wired as proof of closure to prove safety shutoff valves on a startup L1 120 VAC 60 Hz L2 1 2 3 Main Power Burner Start Low Gas High Gas L1 VPS 3 1 L2 4 5 RUN (B) Alarm (S) Interlock Limits Alarm Ignition Pilot Valve L1 N SSOV Flame Safeguard Operation Functional description The VPS 504 proves the integrity and the effective closure of the valve seats by pumping gas from upstream of the main safety valve to the volume between the two safety shutoff valves and detecting leakage. The VPS 504 proves the valves as soon as power is applied. Valve proving should be wired to prove on each start-up. p max. = 7 PSI (500 mbar) Program module Test nipple Connection G 1/8 tap DMV-D(LE) VPS 504 Program sequence + 8 W.C. Program module Program module p Program module 2 5 9 VPS 504 VPS 504 VPS 504 Idle state Idle state: Valves 1 and 2 are closed. Valve proving: The internal pump pumps gas pressure from upstream the first safety valve,, to the volume between the two safety valves. The gas pressure between the two safety shut-off valves,, increases approx. 8 in. W.C. above. During the test period, the internal differential pressure switch monitors the pressure between the two safety valves. Valve Proving If increases approx. 8 in. W.C. above, the motor pump is switched off (end of test period) indicating no leak is detected. The contact RUN (T5) is energized after 26 s max. and the yellow signal lamp lights continuously. (For 24Vdc models, the B terminal is energized) If does not increase approx. 8 in. W.C. above, the motor pump is switched off (end of test period) as a leak is detected. The contact ALARM (T3) is then energized after about 26 s, and the red signal lamp lights continuously. (For 24VDC models, the S terminal is energized) Operation ALARM 1. Switch off appliance 2. Test Valve and/or Valve for tightness manually. 3. If untight replace Valve and/or Valve. The release time (10-20 s) depends on the test volume (max. 0.14 ft 3 ) and input pressure (max. 200 in. W.C.) In the case of short-term voltage failure during test or burner operation, an automatic restart is performed. Operation VPS pump remains off. RUN contact remains energized.

Leak Detection Limit for each Valve 1.6 VPS 504 all series Natural gas; test volume no greater than 0.14 ft 3 Approx. Detection Limit [cfh] +/- 20 % 1.4 1.2 1.0 0.8 0.6 0.4 Maximum Limit Minimum Limit 0.2 0 0 50 100 150 200 Inlet Pressure in. [W.C.] NOTE: Leak detection limit depends on inlet pressure and gas density. To obtain detectable leakage through both valves, divide values in graph by 1.6. Maintenance & Testing Verify that both safety shutoff valves are deenergized and closed prior testing the VPS 504. The VPS 504 is a protective device. Check it at least annually for proper operation. All s must be properly tightened before any gas is reapplied to the system. If the VPS 504 is defective, do not try to repair the unit. Doing so might interfere with ist normal operation and cause a fire or explosion. If disassembled, approvals, warranty and exchange policies will be void. Test Procedure 1. Loosen test nipple. Confirm that gas is not continuously leaking from by applying soapy water to the p2. If bubbles continue, perform a leakage test on the valve seats. 2. Close test nipple, and then simulate a leak by removing test tap at port #2 from the DMV safety shutoff valve on the opposite side of the VPS. With power to the VPS 504, and the upstream ball valve opened, reset the VPS 504 by pressing the red lockout button. Confirm that after the VPS 504 stops pumping, the red light illuminates, and the VPS 504 locks out. (Terminal T3 on S06 series or terminal S on S05 series is energized.) 3. If test procedure 1 or 2 fails, immediately shut down the system, remove, and replace the VPS 504. When the internal pump in the VPS 504 is running, a small amount of gas will flow from port #2 of the DMV. 6 9

Accessories & Replacement Inch (mm) 5.0 (126,5) Cover, electrical connection 4.0 (100) 5.8 (147) 5.9 (150) Standard: 1/2 in. NPT conduit connection for S06. PG 11 with chord grip for S05 2.8 (72) Suction connection (gas input) Pressure connection (to test section) 4.0 (100) Sicherung eingebaut, auswechselbar Fuse built into housing, exchangeable Fusibile integré dans la couvercle du boîtier interchangeable Typ/Type/Type/Tipo T 6,3 L 250 V Betriebsanleitung beachten! Please comply with the operating instructions! Suivre les instructions de la notice d'utilisation! Seguire le istruzioni! Version Order No. VPS 504 S06 (120 VAC 60 Hz) 221-073 VPS 504 S05 (24 VDC) 224-983 PG13, only CSA certified VPS 504 S02 (24 VDC) 225-481 Plug, 7 pin, only CSA certified Accessory Order No. Mounting kit NPT 1/2 (4 mounting screws) 164-760 Mounting kit (for mounting to MVD Valves up to 2 ) 205-360 5.8 (147) 5.9 (150) 4.0 (100) Sicherung eingebaut, auswechselbar Fuse built into housing, exchangeable Fusibile integré dans la couvercle du boîtier interchangeable Fuse Typ/Type/Type/Tipo T 6,3 L 250 V Betriebsanleitung beachten! Please comply with the operating instructions! Suivre les instructions de la notice d'utilisation! Seguire le istruzioni! 5.0 (126,5) 5.0 (126,5) Fuse Sicherung eingebaut, auswechselbar Fuse built into housing, exchangeable Fusibile integré dans la couvercle du boîtier interchangeable Typ/Type/Type/Tipo T 6,3 L 250 V Betriebsanleitung beachten! Please comply with the operating instructions! Suivre les instructions de la notice d'utilisation! Seguire le istruzioni! 5.8 (147) 5.9 (150) 4.0 (100) 5.8 (147) 5.9 (150) 5.0 (126,5) Fuse 4,3 22 pe 53,7 2.8 (72) 7 9 pa 5 13 4,3 22 pe 53,7 2.8 (72) pa 5 Störung Dérangement Blocco Lockout 13 Typ: VPS 504 Serie 02 Betrieb Fonctionamento Funziamento Run Ø 9 Auxiliary fuse Störung Dérangement Blocco Lockout Typ: VPS 504 Serie 02 4,3 Betrieb Fonctionamento Funziamento Run 22 pe Ø 9 53,7 2.8 (72) pa 5 Suction connection (gas input) Auxiliary fuse 13 Pressure connection (to test section) Karl Dungs Inc. 3890 Pheasant Ridge Drive NE Suite 150 Blaine, MN 55449, U.S.A. Phone 763 582-1700 Fax 763 582-1799 e-mail info@karldungsusa.com Internet http://www.dungs.com/usa/ Störung Dérangement Blocco Lockout Typ: VPS 504 Serie 02 Betrieb Fonctionamento Funziamento Run Suction connection (gas input) Pressure connection (to test section) Ø 9 Auxiliary fuse Karl Dungs GmbH & Co. KG P.O. Box 12 29 D-73602 Schorndorf, Germany Phone +49 (0)7181-804-0 Fax +49 (0)7181-804-166 e-mail info@dungs.com Internet http://www.dungs.com Suction con mounts dire Pressure c mounts dir

USA CDN Replacement safety relevant components Austausch sicherheitsrelevanter Komponenten It is necessary to replace safety-relevant components after they have reached the end of their useful life. DUNGS recommends replacing such components according to the following table: Es besteht die Notwendigkeit sicherheitsrelevante Komponenten nach Erreichen ihrer Nutzungsdauer auszutauschen. Austausch gemäss folgender Tabelle: Valid only for domestic, residential and industrial* heating applications. *Not valid for high performance industrial heat process applications. See page 2 Gültig nur für häusliche Heizungsanlagen Nicht gültig für Thermprozessanwendungen mit Taktbetrieb Valve Type Safety relevant component Ventil Typ Sicherheitsrelevante Komponente Recommended replacement after years/cycles: Depends on the value which will be achieved first Empfohlener Austausch nach Jahren/Schaltspielen: Je nachdem welcher Wert zuerst erreicht wird USEFUL LIFE [Years] DUNGS recommends replacement after: USEFUL LIFE [Rated Cycle Life (cycles)] DUNGS recommends replacement after: Max. Cycle Rate Max. Schalthäufigkeit NUTZUNGSDAUER [Jahre] Austausch nach: Änderungen, die dem technischen Fortschritt dienen, vorbehalten We reserve the right to make modifications in the course of technical development. Karl Dungs Inc. 3890 Pheasant Ridge Drive NE Suite 150 Blaine, MN 55449, U.S.A. Phone 763 582-1700 Fax 763 582-1799 e-mail info@karldungsusa.com Internet http://www.dungs.com/usa/ NUTZUNGSDAUER [Schaltspiele (auf/zu)] Austausch nach: DMV-(D) SV-(D) MV(D)/602 1,000,000 cycles 500 /h DMV/MV/SV: 10 Years LE-Ausführungen 10 Jahre (mit Hydraulikbremse) 500,000 cycles 20 /h DMV/MV/SV: LE-Versions (with hydraulic brake) Gasventil mit DUNGS-Ventilprüfsystem Austausch nach erkanntem Fehler Replacement after error detection Gas valve with DUNGS valve proving system VPS 504* 20 /h 250,000 cycles VDK 200* 10 Years 15 /h CPI 400 10 Jahre 1,000,000 cycles @ 1 A and 120 VAC CPI 401 100,000 cycles @ 10 A and 120 VAC 1,000 /h * Valve proving system values shown are expected lifetime. NFPA 86 does not require replacing if the expected life has been exceeded. Karl Dungs GmbH & Co. KG P.O. Box 12 29 D-73602 Schorndorf, Germany Phone +49 (0)7181-804-0 Fax +49 (0)7181-804-166 e-mail info@dungs.com Internet http://www.dungs.com 8 9

USA CDN Replacement safety relevant components Austausch sicherheitsrelevanter Komponenten It is necessary to replace safety-relevant components after they have reached the end of their useful life. DUNGS recommends replacing such components according to the following table: Es besteht die Notwendigkeit sicherheitsrelevante Komponenten nach Erreichen ihrer Nutzungsdauer auszutauschen. Austausch gemäss folgender Tabelle: Valid for high performance industrial heat process applications! Valve Type Safety relevant component Ventil Typ Sicherheitsrelevante Komponente Recommended replacement after years/cycles: Depends on the value which will be achieved first Empfohlener Austausch nach Jahren/Schaltspielen: Je nachdem welcher Wert zuerst erreicht wird USEFUL LIFE [Years] DUNGS recommends replacement after: USEFUL LIFE [Rated Cycle Life (cycles)] DUNGS recommends replacement after: Max. Cycle Rate Max. Schalthäufigkeit NUTZUNGSDAUER [Jahre] Austausch nach: NUTZUNGSDAUER [Schaltspiele (auf/zu)] Austausch nach: MV... /602 NPT 1/2 - NPT 2 (no main flow adjustment) MVD... /602 NPT 1/2 - NPT 1 (with main flow adjustment) 3 Years 3 Jahre 3,000,000 cycles 1,000 /h MVD... /602 NPT 11/4 - NPT 3 (with main flow adjustment) Conditions 1,000,000 cycles Clean gas (NG, LNG, LPG): maximum 50 micron gas filter required! 9 9 Dry Gas: relative humidity < 60 % dew point of the gas < 14 F Not valid for MV(D).../602 valves delivered before 2011/01 Änderungen, die dem technischen Fortschritt dienen, vorbehalten We reserve the right to make modifications in the course of technical development. Karl Dungs Inc. 3890 Pheasant Ridge Drive NE Suite 150 Blaine, MN 55449, U.S.A. Phone 763 582-1700 Fax 763 582-1799 e-mail info@karldungsusa.com Internet http://www.dungs.com/usa/ }"dry" Karl Dungs GmbH & Co. KG P.O. Box 12 29 D-73602 Schorndorf, Germany Phone +49 (0)7181-804-0 Fax +49 (0)7181-804-166 e-mail info@dungs.com Internet http://www.dungs.com