PERCEDOS. Instruction Manual/Technical Information PERCEDOS



Similar documents
DALI RC BASIC SO. Control unit Operating instructions

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Electric mobility: The small charging in between Safe charging with the right charging cable for mode 2

ACS-30-EU-EMDR-10-MOD

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

instabus KNX / EIB System System E F G H

EVR01. General description. Input power cord. S.a.s. di Rizzo Davide & C.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and functional description

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

E-STOP relays, safety gate monitors

Quick Connect. quick - simple - efficient.

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Instruction Manual for Operating Panel 301 and 302

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Electronic Pressure Switch EDS 300

Back-UPS Pro 1300/1500 Installation and Operation

Installation and Operation Back-UPS 1250, 1300, 1500

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Residual current socket 30mA Order No.:

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Safety technique. Emergency stop module BO 5988 safemaster

is then retained absolutely without interruption.

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

SURGE PROTECTIVE DEVICES

Safety automation solutions

User s Manual Before using the inverter, you need to read and save the safety instructions.

UM-X Field display for continous level sensors

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Operating instructions. RCD flat 4-fold, 6-fold

Product Information Sheet UH28CS-12kV Hi Pot Tester

PNOZsigma - Base units

PS 155 WIRELESS INTERCOM USER MANUAL

Fundamentals of Power

How To Use A Power Supply On A Powerline 2.2 (Ai)

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

HOSCH. Sprung blade scraper with heating system. Documentation Type B6C/H

Product Information Sheet UH36 Hi Pot Tester

Electrical connection

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Manual for Fire Suppression & Methane Detection System

Online UPS. PowerWalker VFI 1000R/1U

HM-W536 Install Guide

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

NX Series Inverters. HVAC Pocket Programming Guide

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Automatic Phone-Out Home Monitoring Systems

TMS TANK MANAGEMENT SYSTEM

TCR easy Plus Alarm. Operating Instructions

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Combi switchbox with integrated 3/2 way pilot valve

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Mounting and System Description for SSZ-Safety-Mats

Operating instructions IV / 2007

magnetronic GmbH Kreuzhofstr München Tel.: 089/ Fax: 089/ Battery control system DCC 6000

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

PROCESS AUTOMATION MANUAL OVERSPEED/UNDERSPEED MONITOR KF**-DWB-(EX)1.D ISO9001

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Electrical Resistance Resistance (R)

User Manual for CH-PFC76810

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

INDEPENDENT HOBS WITH HIC ELECTRONIC CONTROL

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

CONFIGURABLE SAFETY RELAYS

Charge Controller CC611/CC612 Preliminary datasheet

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

ELECTRIC CENTRAL HEATING FLOW BOILER

Analog Command Value Card Type VT-SWKA-1

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

1 Technical Description Lokal-200PC

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Photovoltaic Solar Energy Unit EESFB

Installation and safety instructions for AC/DC built-in devices

Inwall 4 Input / 4 Output Module

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Model SETR-50 and SETR-51 Trim Tab Control

Installation & User Manual Radio Remote rev1.0.3

CONFIGURABLE SAFETY RELAYS

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

E-STOP relays, safety gate monitors

Addendum to the Operating Instructions

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Transcription:

PERCEDOS Instruction Manual/Technical Information PERCEDOS

Function description: PERCEDOS is a portable protective system (IC-RCD*) including communication interface to the electrical vehicle and intended for use on the charging cable in mode 2. The device checks the power supply for proper function and only allows current to be drawn from a safe power source. The charger of the electrical vehicle controls the charging procedure of the batteries and prompts the PERCEDOS to switch the charging procedure on or off means of the communication connection. In order to activate the charging procedure, the PERCEDOS must be activated. An inactive PERCEDOS status is the equivalent of a stand function. Without PERCEDOS, it is impossible to charge the vehicle in mode 2. When connected to an outlet, the device automatically recognizes whether mains voltage is present at the feed point. It is not necessary to manually switch on the PERCEDOS If mains voltage is recognized, the device automatically starts the protective ground monitoring. This monitoring function is constantly active as long as the device is operated with mains voltage and monitors the protective ground connection between PERCEDOS and the outlet for the presence of the protective ground wire and its freedom from faults. So that the PERCEDOS can detect external voltage on the protective ground, the device must be connected to the electrical vehicle. The function external voltage detection is also automatically activated as soon as the plug connection to the vehicle has been created and detected. As soon as the PERCEDOS finds one of these faults, the charging procedure is immediately interrupted or a beginning of the charging procedure is prevented The fault current circuit breaker integrated into the device additionally protects the user against an electrical accident in case of a system defect. Sequence of the charging procedure: 1. Check the maximum possible charging current of the outlet and reparameterize the charging current of the PERCEDOS after connection to the mains voltage, if necessary. 2. Connect PERCEDOS to outlet (mains voltage) and to vehicle. 3. PERCEDOS automatically starts its test sequence; (outlet and connection cables) are checked for proper function. 4. After the test sequence and if no malfunctions have been determined, the PERCEDOS is ready to activate the charging procedure. 5. For this, the PERCEDOS must be activated in operating status. 6. Check operating status and switch to active if necessary 7. The charging current of the PERCEDOS may need to be reparameterized. 8. The vehicle electronics switch the PERCEDOS on and off for the charging procedure. * IC-RCD = In Cable - Residual Current Device 2

Protective ground monitoring - external voltage detection: Depending upon the connection configuration, the protective ground is monitored as follows: PERCEDOS connected to outlet (mains voltage) without connection to the vehicle: The symbols vehicle, PERCEDOS, and power column blink red/green for approx. 2 seconds. The constant monitoring of the protective ground connection (PE) between the PERCEDOS and the outlet for wire breakage is activated. No external voltage detection possible. PERCEDOS connected to outlet (mains voltage) and vehicle: The symbols vehicle, PERCEDOS, and power column blink red/green for approx. 2 seconds. The constant monitoring of the protective ground connection (PE) between the PERCEDOS and the outlet for wire breakage is activated. The constant detection of external voltage on the protective ground wire is activated. PERCEDOS only attached to the vehicle: Device is not being supplied with mains voltage (device off). No visual feedback possible. No protective ground monitoring possible. No external voltage detection possible. Possible results of the protective ground monitoring - external voltage detection: There is no protective ground connection between the PERCEDOS and the outlet (mains connection). Charging procedure is not activated. Display power column blinks red. The protective ground connection between the PERCEDOS and the outlet (mains connection) is interrupted during the charging procedure. The current charging procedure is switched off. Display power column blinks red. Protective ground wire between electrical vehicle, PERCEDOS, and outlet (mains connection) is carrying external voltage. Charging procedure is not activated. The current charging procedure is switched off. Display power column blinks red. Check the charging cable and plug connections. Use another outlet. Then, restart the charging procedure. 3

"Activate/deactivate" PERCEDOS operating status: If no fault is detected after commissioning and test sequence, the charging procedure is permitted. For this, the device must be activated in operating status. The PERCEDOS is delivered inactive. The respective operating status, whether active or inactive, is permanently saved in the device even in case of power loss. For every startup or after the return of voltage note which operating status the device assumes after fault-free test sequence. If the device was deactivated as its last operating status inactive, the PERCEDOS must be switched to active so that the vehicle can be charged. Activate PERCEDOS : Press button (I). Charging procedure activated. Display PERCEDOS illuminates green. Deactivate PERCEDOS : Press button (0). The charging procedure is switched off or interrupted. Stand mode. Battery charging procedure: Only possible if the PERCEDOS has not detected any fault and is activated. Stand Vehicle connection has been detected. Charging procedure possible, but not yet switched on the vehicle electronics. Current indicators are off. Display vehicle illuminates red/green. Charging procedure Charging procedure was switched on the vehicle electronics. Vehicle battery is being charged. Maximum possible current level illuminates yellow. Momentary current level illuminates as a green bar. Display vehicle blinks green. Charging procedure concluded: Vehicle batteries are completely charged. Current indicators are off. Display vehicle illuminates green. Switch PERCEDOS to inactive and remove the connections to the vehicle and the mains connection. Vehicle operation can be resumed. Charging procedure not possible: Communication error between the PERCEDOS and the electrical vehicle. Ventilation required the vehicle electronics is not present, not activated, or faulty Display vehicle blinks red. Current indicators are off. 4

Parameterization mode charging current: When connecting the electrical vehicle to an unknown power source, the maximum possible charging current of the power source should be checked before the beginning of the charging procedure. Example: If the utilized power source is fused for 13A, the maximum possible charging current on the PERCEDOS must be reduced one level from 16A to 13A. Otherwise, the power source will be overloaded. The fuse can trigger prematurely or the connection cables will be destroyed overheating. Five different current levels can be set manually. (16A, 13A, 11A, 8A, 6A). As delivered, the maximum possible charging current is preset at 16A. Parameterization of the maximum possible charging current is only possible inactive operating status. To manually parameterize the maximum possible charging current, proceed as follows: Check the operating status of the PERCEDOS and switch from active to inactive, if necessary. Then, press button (0) and button (I) simultaneously and keep pressed for approx. 5 seconds. During initial parameterization (delivered status), all of the LED s of the current indicator light up. Current indicator illuminates as yellow bar. If charging current parameterization has already been performed and this setting will now be changed, the yellow bar illuminates up to the previously set maximum possible current level. Example: Preset 13A maximum possible charging current corresponds to 80% of the bar display. Reduce maximum possible charging current: Press button (0). Each time the button is pressed, the maximum possible charging current is reduced one charging level until the lowest charging level is reached. Increase maximum possible charging current: Press button (I). Each time the button is pressed, the maximum possible charging current is increased one charging level until the highest charging level is reached. Close charging current parameterization: Parameterization mode is automatically closed if no button is pressed for at least 5 seconds. Yellow current indicator goes out completely. 5

Temperature monitoring: In order to ensure safe charging of the electrical vehicle at all times, the PERCEDOS has internal temperature monitoring and temperature-related charging current optimization. This ensures that the permissible charging current is set automatically with consideration for safety aspects. This guarantees safe, unsupervised operation with optimized charging times. Charging current optimization means of internal temperature monitoring: The temperature monitoring is switched on automatically, as soon as the charging of the vehicle battery begins. As soon as the temperature sensor measures an excessive temperature, the preset charging current is automatically reduced one charging level (e.g. from 16A to 13A). In case of temperature reduction, the charging current is automatically increased one charging level up to the maximum possible charging current (e.g. from 13A to 16A). The charging procedure is permanently switched off if the excessive temperature continues to be measured when the lowest charging level of 6A is reached. Display PERCEDOS illuminates red. Display vehicle and current indicators are off. Switch-off in case of critical temperature: If a critical temperature occurs, the charging procedure is immediately permanently switched off. Display PERCEDOS illuminates red. Display vehicle and current indicators are off. Reset of temperature monitoring: If the charging procedure has been permanently switched off automatically the temperature monitoring, this must be manually reset after eliminating the fault. For this, proceed as follows: Switch the operating status of the PERCEDOS from active to inactive. This resets the temperature monitoring. If the charging procedure is to be continued, switch the operating status of the PERCEDOS from inactive to active. Display PERCEDOS illuminates green. Only reset temperature monitoring if the cause of the excessive temperature has been eliminated and the device has first been tested for proper function, e.g. testing an electrician. 6

Fault current circuit breaker: A fault current circuit breaker has been integrated into the device, which additionally protects the user against an electrical accident in case of a system defect. Automatic switch-off in case of detected differential fault current: In case of detected differential fault current IVn 30 ma, the PERCEDOS initially switches off the charging procedure temporarily. Display PERCEDOS illuminates red. Display vehicle and current indicators are off. The PERCEDOS will reactivate the charging procedure up to three times with a waiting period of 20 seconds. If the fault still exists, the charging procedure will no longer be allowed after it is switched off for the fourth time (permanent switch-off). Display PERCEDOS illuminates red. Display vehicle and current indicators are off. Manual test of the differential fault current monitoring: Check the operating status of the PERCEDOS and switch from active to inactive, if necessary. Then, press the button (0) again for approx. 1 second. Test of the differential fault current monitoring is started. Display PERCEDOS goes off. Possible results of the manual test of the differential fault current monitoring: Fault current triggering is working properly: The charging procedure can begin or be continued. For this, switch the operating status back to active. Fault current triggering is not working properly: Do not switch on charging procedure. Have the PERCEDOS checked immediately an electrician! 7

Fault current monitoring: If the charging procedure has been permanently switched off automatically the activation of the differential fault current monitoring, this must be manually reset after eliminating the fault. Display PERCEDOS illuminates red. For this, proceed as follows: Switch the operating status of the PERCEDOS from active to inactive. This resets differential fault current monitoring. If the charging procedure is to be continued, switch the operating status of the PERCEDOS from inactive to active. Display PERCEDOS illuminates green. Only reset differential fault current if the cause of the fault current has been eliminated and the device has first been tested for proper function, e.g. testing an electrician. Service functions: In order to ensure sae charging of the electrical vehicle at all times, PERCEDOS has internals protective mechanisms. A periodic self-test checks the internal differential fault current function and an operating hours meter monitors the maximum recommended operating time until the next retesting Periodic self-test: The PERCEDOS checks the differential fault current function with the aid of an internal self-help routine. This self-test is automatically performed every 4 operating hours, both in active and inactive operating status. The running of the self-test does not have an influence on the charging procedure. Operating hours meter: The operating hours meter keeps track of the active charging time until the next service interval. We recommend having the PERCEDOS checked an electrician after every 5,000 operating hours. Possible results of the service functions: Display PERCEDOS illuminates green. No error determined during differential fault current testing. Maximum operating hours not yet reached. PERCEDOS operating status is active. Charging procedure is possible and activated. No error determined during differential fault current testing. Maximum operating hours not yet reached. PERCEDOS operating status is inactive. Charging procedure would be possible but is not activated. 8

Display PERCEDOS illuminates constantly red/green. Error has occurred during differential fault current testing, or operating hours have been exceeded. PERCEDOS operating status is active. Charging procedure still possible and activated. Cancel charging procedure. Have the PERCEDOS checked immediately an electrician! Display PERCEDOS blinks red/green. Error has occurred during differential fault current testing and/or operating hours have been exceeded. PERCEDOS operating status is inactive. Charging procedure would be possible but is not activated. Do not switch on charging procedure. Have the PERCEDOS checked immediately an electrician! Reset operating hours meter: The operating hours meter can be manually reset in inactive operating status. For this, proceed as follows: Check the operating status of the PERCEDOS and switch from active to inactive if necessary. Then, press the button (0) again for approx. 2-3 seconds. This resets the operating hours meter. Only reset the operating hours meter if the device has first been tested for proper function, e.g. testing an electrician! Notes: Follow the rules of electrical engineering and the technical data. Do not make any changes to the device. You can find additional information and an overview of the assortment under www.kopp.eu. 9

PERCEDOS mk4 Series mk4 Article-No.: 2940.0001.0 The listed facts relate to the technical data of the expected serial device. This data may be modified according to technical and normative (further development) evolution. For the single device the enclosed data sheet is effective. Function Technical data Rated voltage 160 240V~; 1-phase; ± 10% Rated current 16A Frequency 50Hz Switching capacity 3,600W (permanent load at 230V~) Power discipation approx. 7W Stand consumption < 1W Nominal residual current I n 30mA / I n 10mA on request Tripping characteristic (RCD) Typ A Charging current 5-steps 16A/13A/10A/8A/6A Parameters adjustable at manufacturing process Automatical treduction of charging current at over-temperature Programming mode manually adjustment of permitted charging load Parametering interface integrated Disconnection all pole (L,N,PE) according Norm IEC 62335 Circuitry Relais with electric strength > 1.500 V / short-circuit strength 1.500 A Power connection L, N, PE / 1-phase L1, L2, PE / 1-phase Usable main power supply networks TN: TN-C, TN-C-S, TN-S Operating hours of charging > 40,000h Protection class IP 55 Environmentral Temperature 30 C to +50 C Dimensions (l x w x h) approx 210 x 80 x 68 mm Weight approx 600 g Operating elements 2 push-buttons (tactil) with pre-stamped keypad suitable for left- and right-handed persons Operating functions ON, OFF/Test; Prog-Modus; +; - Display function concept self-explaining graphical touch panel and function display Imagery (ecar, PERCEDOS, charging pillar) Dispaly colour back-illuminated imagery colour variance: red = failure; green = active; red/green = service or Stand Service indication after 5,000h Periodical self test function every 4h Thermal monitoring mandatory: Internal temperature observation (NTC-resistance) optional: External temperature observation (NTC-resistance in power supply plug) Vehicle communication Integrated communication modul (PWM) according IEC 61851 Data port short-circuit proof Saftey functions Residual Current Device (RCD Type A) Protection Conductor Presence (PCP) Protection Conductor Monitoring (PCM) Operation recognition Automatic restart after power failure. The PERCEDOS must be previously activated and not switched off through residual current. No automatic restart after manual switch off Undervoltage release Undervoltage release with automatic reset after self test procedure Case fastener screwed with safety torx screws exclusively to open from professionals Protection against misuse 1. PERCEDOS only operates in Mode 2 2. Cabinet can not opened with ordinary tools Cord grip cord crip on both side with 2 torx screws surface tempered according DIN ISO 4042, zinc coated 5µm A2x Connector cable protective sleeve both side sealed range for IP 55: cable fitting 6 13mm protective sleeve 11,6 mm ± 0,4 mm Connector pins for power voltage receptacle 6,3x0,8 Ms (Type: Tyco 63012-2 or equivalent) Connector pins for temperature sensor receptacle 2,8x0,5 Ms or 2,8x0,8 Ms and communication wire Prefered components Automotive standard Certification and manufacturer's declaration CE self declaration (based on VDE information test) Standards IEC 61851-1:2001; IEC 62196-1:2003; IEC 62335; ISO 6722 10

PERCEDOS mk4 Indications on the PERCEDOS display: No displays: no mains voltage Charging station: 1. No display (off): no mains voltage. 2. Illuminates green: charging procedure possible. 3. Blinks red: charging procedure not possible. Outlet fault. 1. 2. 3. PERCEDOS: 1. No display (off): no mains voltage or outlet fault. 2. Illuminates green: device activated. 3. Blinks green: device deactivated. 4. Blinks red: detected fault current. Temporary switch-off. 5. Illuminates red: detected fault current. Permanent switch-off. 6. Illuminates red/green: periodic self-test has activated. Operating hours exceeded. 1. 3. 5. 2. 4. 6. Current indicator: 1. Displays illuminates: when the vehicle is being actively charged. Otherwise, no display (off). 2. Illuminates green: momentary current level. 3. Illuminates yellow: maximum possible current level. 1. 2. 3. Vehicle: 1. No display (off): No mains voltage. No vehicle detected. Switch-off due to fault current. Switch-off due to temperature. 2. Illuminates green: vehicle battery completely charged. 3. Blinks green: vehicle is being charged. 4. Illuminates red/green: vehicle connection detected, no charging procedure. 5. Blinks red: charging procedure not possible, communication error, among others. 1. 3. 5. 1. 2. 4. Dimensional drawing (all dimensions in mm) 11

Heinrich Kopp GmbH Alzenauer Straße 68 63796 Kahl/Main GmbH Theodor-Simoneit-Straße 2 A-4160 Aigen Telefon: +49 6188 40-0 Telefax: +49 6188 8669 Vertrieb, Telefax: +49 6188 40-369 Internet: http://www.kopp.eu E-Mail: vertrieb@kopp.eukopp Austria Tel: +43 7281 Technische 6566-0 Beschreibungen, Abbildungen und Leistungsangaben Fax: +43 7281 stellen 8790keine zugesagten Eigenschaften dar, sondern sind nur unverbindliche Informationen. Änderungen aufgrund technischen Fortschritts, Normänderungen, veränderter Fertigungsverfahren oder Konstruktionverbesserungen bleiben ausdrücklich vorbehalten. Art.-Nr. xxxx.xxxx.x/du10100097 110908-1649