An Introduction to Electrochemical Impedance Measurement



Similar documents
Electrochemical Impedance Spectroscopy (EIS): A Powerful and Cost- Effective Tool for Fuel Cell Diagnostics

Understanding ir Compensation

PHASOR DIAGRAMS HANDS-ON RELAY SCHOOL WSU PULLMAN, WA. RON ALEXANDER - BPA

SERIES-PARALLEL DC CIRCUITS

Impedance Matching. Using transformers Using matching networks

The Potentiodynamic Polarization Scan. Technical Report 33

Positive Feedback and Oscillators

RLC Resonant Circuits

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

An Introduction to Electrochemical Impedance Spectroscopy (EIS)

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

CURRENT ELECTRICITY INTRODUCTION TO RESISTANCE, CAPACITANCE AND INDUCTANCE

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

Capacitors in Circuits

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

Relationship between large subject matter areas

Application of network analyzer in measuring the performance functions of power supply

Laboratory 4: Feedback and Compensation

Electrical Resonance

Electronics for Analog Signal Processing - II Prof. K. Radhakrishna Rao Department of Electrical Engineering Indian Institute of Technology Madras

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

LABORATORY 2 THE DIFFERENTIAL AMPLIFIER

Understanding Power Impedance Supply for Optimum Decoupling

SCHWEITZER ENGINEERING LABORATORIES, COMERCIAL LTDA.

Technical Note #3. Error Amplifier Design and Applications. Introduction

GENERAL POWER SYSTEM WIRING PRACTICES APPLIED TO TECNADYNE DC BRUSHLESS MOTORS

Grounding Demystified

Inductors in AC Circuits

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

Objectives. Electric Current

Transistor Characteristics and Single Transistor Amplifier Sept. 8, 1997

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

Reading: HH Sections , (pgs , )

Diodes have an arrow showing the direction of the flow.

GenTech Practice Questions

Slide 1 / 26. Inductance by Bryan Pflueger

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

V out. Figure 1: A voltage divider on the left, and potentiometer on the right.

MUIRHEAD AEROSPACE Synchros

A wave lab inside a coaxial cable

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Electromagnetism Laws and Equations

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Alphasense Application Note AAN DESIGNING A POTENTIOSTATIC CIRCUIT

Lecture 24. Inductance and Switching Power Supplies (how your solar charger voltage converter works)

The Autolab control command is located in the Measurement General group of commands.

Fundamentals of Signature Analysis

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

Physics 6C, Summer 2006 Homework 2 Solutions

VOLTAGE REGULATOR AND PARALLEL OPERATION

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

Input and Output Capacitor Selection

ANALYTICAL METHODS FOR ENGINEERS

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

AP1 Electricity. 1. A student wearing shoes stands on a tile floor. The students shoes do not fall into the tile floor due to

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Keysight Technologies Understanding the Fundamental Principles of Vector Network Analysis. Application Note

Three phase circuits

AN-837 APPLICATION NOTE

Fundamentals of Microelectronics

Chapter 10. RC Circuits ISU EE. C.Y. Lee

EIS investigation of CO 2 /H 2 S corrosion

Experiment 7: Familiarization with the Network Analyzer

Lecture 18: Common Emitter Amplifier. Maximum Efficiency of Class A Amplifiers. Transformer Coupled Loads.

Voltage/current converter opamp circuits

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

Precision Diode Rectifiers

Application Note AC-1

Active Vibration Isolation of an Unbalanced Machine Spindle

AP Physics Electricity and Magnetism #4 Electrical Circuits, Kirchoff s Rules

Reading assignment: All students should read the Appendix about using oscilloscopes.

EDUMECH Mechatronic Instructional Systems. Ball on Beam System

REPORT ON CANDIDATES WORK IN THE CARIBBEAN ADVANCED PROFICIENCY EXAMINATION MAY/JUNE 2008 ELECTRICAL AND ELECTRONIC TECHNOLOGY (TRINIDAD AND TOBAGO)

Introduction to Electricity & Magnetism. Dr Lisa Jardine-Wright Cavendish Laboratory

Basic Op Amp Circuits


Chapter 12: The Operational Amplifier

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

DIELECTRIC SPECTROSCOPY AS A DIAGNOSTIC TEST METHOD FOR THE DETERMINATION OF MECHANICAL DAMAGE IN MARBLE SAMPLES

Lab E1: Introduction to Circuits

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Physics 120 Lab 6: Field Effect Transistors - Ohmic region

Series and Parallel Circuits

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

Bruce B. Weiner, Walther W. Tscharnuter, David Fairhurst Brookhaven Instruments Corporation Holtsville, NY US

ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS

Power Supplies. 1.0 Power Supply Basics. Module

DRAFT. University of Pennsylvania Moore School of Electrical Engineering ESE319 Electronic Circuits - Modeling and Measurement Techniques

PCM Encoding and Decoding:

reduction ore = metal oxides metal oxidation

Single-Stage High Power Factor Flyback for LED Lighting

RF Network Analyzer Basics

Transcription:

An Introduction to Electrochemical Impedance Measurement Technical Report No. 6

An Introduction to Electrochemical Impedance Measurement N D Cogger and N J Evans Technical Report No. 6 Part No.: BTR006 Issue: 05 - May 99 Solartron Limited, 1999

Solartron Solartron Victoria Road 37 rue du Saule Trapu Farnborough, 91882 MASSY, Cedex Hampshire GU14 7PW France England Tel: +44 (0) 1252 376666 Tel: +33 (1) 69 53 63 53 Fax: +44 (0) 1252 544981 Fax: +33 (1) 60 13 37 06 Solartron Solartron 964 Marcon Boulevard Beijing Liaison Office Suite 200 Room 327, Ya Mao Building Allentown, PA 18103 No. 16 Bei Tu Cheng Xi Road USA Beijing 100101, PR China Tel: +1 610 264 5034 Tel: +86 10 6238 4687 Fax: +1 610 264 5329 Fax: +86 10 6202 8617 Email: Web: solartron@solartron.com http://www.solartron.com For details of our agents in other countries, please contact our Farnborough, UK, Office.

Introduction The rapid and accurate measurement of electrochemical phenomena is of considerable importance for a range of studies, not only in research, but also in practical applications. Typical subjects include corrosion, effectiveness and life of surface coatings, battery testing and the investigation of biological and photoelectric effects. Of these, corrosion and surface treatments are probably the most important applications, although the basic mechanisms determining the characteristics of, for example, batteries are broadly similar. It is possible to measure effects such as corrosion rate, or battery life, by direct analytical methods, for example weight loss measurements or solution analysis by spectroscopy; but, because the processes are slow, these methods are time consuming and inefficient. Additionally, they are restricted to systems in which the products formed by the process do not form adherent layers. Because the processes under consideration are electrochemical, it is possible to analyse them using electrical methods, based on Faraday s law which relates the change in mass per unit area to the current flow. The advantages of this approach are a relatively short measuring time, high accuracy and the possibility of monitoring the process continuously. Naturally there are also disadvantages, the major of these being that the system under investigation has to be perturbed from its normal state by an external signal, which inevitably changes the properties of the system. The perturbation itself can be due to an ac or dc signal and it is primarily with ac methods that this paper is concerned. The dc technique has been widely used for corrosion rate measurement, but the method generally requires a relatively large perturbation (or polarisation) signal and can, in fact, fail when the corrosion process is taking place in a low conductivity medium. Ac methods are finding increasing applications in electrochemical research, because only small perturbation signals (which do not disturb the electrode properties) need to be used and low conductivity media can be investigated. Principles of Electrochemical Measurements If a potential (voltage) is applied across an electrochemical cell (corroding material, battery etc.) a current is caused to flow through the cell, with a value determined by the mechanisms of the reaction taking place. The reaction is the formation of new chemical species as result of the movement of ions through the electrolyte. The ionic movements are caused by the applied potential difference, and constitute a flow of electric current. If the applied potential is a sinusoid ( Esinωt) then the subsequent current will also be sinusoidal, with a value isin (ωt + φ). Harmonics of this current (2ω, 3ω... etc.) will also flow. The relationship between the applied potential and the current flow is known as the impedance, which is analogous to the resistance-current-potential relationship of a dc circuit. The impedance (Z) has a magnitude ( E/ i) and phase (φ) and is thus a vector quantity. Now, if a sinusoidal potential is applied across a pure resistance of magnitude R, then the magnitude of the impedance Z = R and the phase φ = 0 for all frequencies. This is shown on a plot of the real (a) and imaginary (jb) components as a point on the real axis (Figure 1) overleaf. BTR006 1-1

R - jb ω C R a Figure 1 - Complex plane impedance spectrum - resistance If the sinusoid is applied across a pure capacitance, the impedance is now dependent on the frequency, according to the relationship Z = 1/ωC and the phase angle is 90. As the frequency increases the magnitude of the impedance decreases, as shown in the plot (Figure 2). - jb C ωc l ω Figure 2 - Complex plane impedance spectrum - capacitance The result of combining these two basic circuit components, in series or parallel, can be easily deduced, with two simple examples being shown in Figure 3, for a series resistance and capacitance and a parallel resistance and capacitance. a 1-2 BTR006

- jb ω R C ωc l Figure 3a - Complex plane impedance spectrum - series resistance, capacitance R a R - jb ω C Figure 3b - Complex plane impedance spectrum - parallel resistance, capacitance An electrochemical cell can be represented by a network of resistors and capacitors - known as an equivalent circuit. From an impedance spectrum, (plotted in the real/imaginary plane, or as gain and phase versus frequency) it is possible to deduce the equivalent circuit and determine the significance of the different components. In order to understand the measurement instrumentation used to derive the impedance characteristics it is necessary to look at some basic aspects of the electrochemical cell. The most basic form of a cell comprises two electrodes immersed in an electrolyte (Figure 4). Application of a potential across the electrodes causes a current to flow through the cell. The electrodes are known as the working electrode, at which the interface between electrolyte and electrode is investigated and the secondary (or counter) electrode, which allows the current to pass through the cell. This type of arrangement is used for the investigation of electrolyte properties, such as conductivity, when the dominant parameter is the electrolyte resistance. R a WE SE Figure 4-2-terminal electrochemical cell BTR006 1-3

In other cases the reaction at the working electrode needs to be examined to determine the relationship between the current on the one hand and the voltage that is required to drive this reaction on this other. This requires a third electrode (the reference electrode). Measurement of the potential between the working and reference electrodes allows the change in potential of the working electrode needed to cause current to flow to be found. Normally the reference electrode is remote from the working electrode, in a separate compartment. The compartment is then connected with the working electrode by a narrow glass tube (known as the Luggin capillary) which contains the electrolyte. This permits separation of the bulk properties of the electrolyte from the interfacial properties (Figure 5). The arrangement does, however, impose a small (but, in some cases, significant) additional resistance due to the electrolyte between the tip of the Luggin capillary and the working electrode. This is minimised by placing the two as close as possible without disturbing the current flow to the working electrode. 1-4 BTR006

WE SE RE Figure 5-3-terminal electrochemical cell Finally, a 4-terminal cell can be used to provide an analysis of processes occurring within the electrolyte, between two measuring electrodes separated, for example, by a membrane. In this case the purpose of the working and secondary electrodes is only to enable the current flow. This permits the study of ion transport through the membrane (Figure 6). WE SE RE1 RE2 Figure 6-4-terminal electrochemical cell BTR006 1-5

The 1287 Electrochemical Interface To make the measurements outlined above, a correlation frequency response analyser (FRA), such as the Solartron 1250, or 1255, can provide a sinusoidal excitation signal and measure the response to this as a ratio of one channel to the other. If the response signals represent, on one channel, the cell potential and on the other the cell current, then the impedance (or admittance) can be measured. The analyser however, cannot always be connected directly to a cell and requires an interface with suitable input/output and control characteristics - these are provided by potentiostat such as the 1287 Electrochemical Interface. The basic circuit of the 1287 is shown in Figure 7, from which it can be seen that the instrument may be considered in five basic parts: 1. Adding amplifier - providing the cell polarisation level. 2. Polarisation control 3. Electrode connection 4. Current measurement 5. Voltage measurement Adding Amplifier Polarisation Control Current Measurement Voltage Measurement Reference Voltage Generator Input SE RE1 RE2 WE Outputs to FRA 2-terminal 3-terminal 4-terminal Figure 7 - Schematic of 1287 Electrochemical Interface 1-6 BTR006

Each of these sections will be described briefly: 1. Polarisation Level Two polarisation signals are available, dc and ac, these being summed in the adding amplifier. The dc signal can be used on its own to measure the dc characteristics of a cell (such as current-potential curves) or in conjunction with the ac signal. The ac signal is derived from the FRA generator, generally as a high amplitude signal which is then divided by 100 at the 1287 input to provide a good quality, low amplitude signal to perturb the cell. 2. Polarisation Control To avoid problems of cell stability when applying the polarisation signal, and to enable multi steady state systems to be investigated, it is necessary to regulate the applied signal. This is achieved by applying negative feedback to ensure that the polarisation of the electrochemical interface follows a reference quantity set by the experimenter. The regulated quantity may be the interface potential (for potential measurements), or the interface current (for galvanostatic measurements) and is compared with the reference quantity using a differential amplifier. A difference in the two quantities causes the regulated quantity to be adjusted by a change in the amplifier output to make this difference zero. The regulated polarisation level is then output to the secondary electrode of the cell, SE, via a cut-out switch, which isolates the cell if the current becomes saturated. This avoids damage to the cell if the system goes unstable. 3. Electrode Connections The two reference electrodes (RE1 and RE2) are used to measure the required characteristics and the working electrode (WE) provides the electrode/electrolyte interface at which the reaction occurs. For 2-terminal cells RE1 is connected to SE and RE2 to WE, at the cell. For 3-terminal cells RE1 is used to measure the interface characteristics (via, for example, a Luggin capillary) while RE2 remains connected to WE. In the 4-terminal mode the electrodes are connected independently. 4. Current Measurement Current measurement is based on Kirchoff s laws, using a virtual earth technique. The current to the virtual earth is the same as that flowing through the Standard Resistor in the feedback loop, where the Standard Resistor is selected to match the impedance of the cell as closely as possible. This technique avoids loading the circuit, as happens with the series resistor method. The voltage due to the cell current is output to the FRA input appropriate to the characteristic (impedance or admittance) being measured. 5. Voltage Measurement The voltage, or potential, is measured using a high impedance differential amplifier across the reference electrodes and, again, output to the FRA. In both current and voltage measurement any dc content in the signal may be backed-off at the 1287 output, so that the FRA receives only the ac content. Two other features are provided: Real Part Correction and Positive Feedback Polarisation Control (IR Compensation). Real part correction allows an amount to be subtracted from the in-phase (real) component, equivalent to the electrolyte resistance due to the distance between the reference electrode capillary (Luggin tip) and the working electrode. It will be remembered that a pure resistance provides a response to a sinusoid which has a zero phase shift for all frequencies. BTR006 1-7

IR compensation uses positive feedback to compensate for the effect of the electrolyte resistance, but is subject to instability. Figure 8 - Examples of non-linear current-potential curves (a) Exponential-shaped curve: potential or current-controlled interface. (b) N-shaped curve: potential-controlled interface. (c) S-shaped curve: current-controlled interface. Choice of potentiostatic (constant voltage) or galvanostatic (constant current) control of the cell under test is governed by its dc current-potential characteristics. Figure 8 shows examples of typical non-linear current-potential curves. Figure 8a can be derived by use of either a potential- or a current-controlled interface, as each point on the curve has a unique identity on both current and potential axes. For a response such as that shown in Figure 8b, the cell characteristic can only be obtained by potentiostatic operation. Were galvanostatic control to be used, an increasing current would cause the characteristic to follow the path OB AA M, whereas a decreasing current would produce the path MA BB O. Voltage control would allow the full characteristic OB ABA M to be determined unambiguously. Similarly, galvanostatic control is required to obtain the cell response shown in Figure 8c. 1-8 BTR006

It is also possible, while setting up or running a test, to monitor the potential at a relevant terminal, or measure the current, using either the 1287 s own display, or an external dvm connected to the sockets on the rear panel. Interpretation of AC Impedance Measurements It has been shown that an FRA, used in conjunction with a potentiostat such as the 1287 Electrochemical Interface, allows a cell to be stimulated with an ac signal and the response, in terms of the cell potential and current, measured. Using the transfer function facility of the FRA the impedance (or admittance) can be determined directly. It will be recalled from the earlier discussion that a plot of the impedance, either as the real and imaginary parts against frequency, or the magnitude and phase against frequency, allows the characteristics of the system to be established. As an example, a simple corrosion system can be represented by a parallel capacitance and resistance (which represent the corroding interface) in series with a second resistance, as shown in Figure 9. The response of this equivalent circuit is shown as an Argand diagram, from which the values of the circuit elements can be determined. R t - jb ^ l ω = C dl R t R Ω C dl Z φ R Ω ω a R Ω + R t Figure 9 - Complex plane impedance spectrum - simple equivalent circuit The series resistor, R Ω, represents the resistance of the electrolyte, surface films and the leads used to connect the cell to the measuring system etc. The parallel resistance, R t, is known as the charge transfer resistance and determines the rate of the corrosion reaction. The capacitance, C dl, is known as the double layer capacitance, which occurs at the electrode/electrolyte interface. The electrode surface has a charge, due to an excess or depletion of electrons, which resides with the atoms in the first layer of the surface and is balanced by an equal number of oppositely charged particles in the electrolyte. The distribution of this charge determines the field strength of the interface, which, in turn, defines the speed of ion transfer. To summarise the behaviour of this simple circuit; at high frequencies the capacitance (C dl ) conducts easily (effectively shorting out the charge transfer resistance R t ) leaving only the effect of the conduction series resistance (R Ω ). As the frequency decreases the conduction of the capacitance becomes less and less and the response due to R t increases. As the frequency approaches zero the capacitor ceases to conduct and the cell impedance is a function only of R t and R Ω. For most practical systems this simple approach is insufficient to define the reaction process and more complex models, or equivalent circuits, need to be derived. These include the effects of diffusion of charged species (e.g. ions) and the presence of inductive loops (with a positive imaginary component), the significance of which is not, at present, clearly understood. BTR006 1-9

R t W - jb R t ω ω C dl a Figure 10 - Complex plane impedance spectrum - equivalent circuit with Warburg impedance A typical equivalent circuit, to include mass transfer diffusion effects, is shown in Figure 10. The additional element, known as the Warburg impedance, is a complex quantity having real and imaginary parts which are equal. This impedance is proportional to the reciprocal of the square root of the frequency (1/ ω). At high frequencies, therefore, this term is small and the diffusion process is only observed at low frequencies. Here the semicircle is distorted by the Warburg impedance (represented by a straight line at 45 to the axis). This simple analysis predicts that the Warburg impedance diverges from the real axis, but in practice the dc resistance of the cell is finite. Diffusion layer effects then cause the low frequency end of the impedance to bend over the real axis, giving rise to a double semicircle (Figure 11). Other effects, such as time constant dispersion, due to inhomogeneities in the electrode surface (which depresses the semicircle) and adsorption (which results in a second, low frequency semicircle) also further complicate the analysis. - jb ω 0 Figure 11 -.Complex plane impedance spectrum - Warburg impedance as approaches 0 It can be seen from the diagrams (Figures 8, 9, 10, and 11) that the basic parameters - electrolyte resistance, double layer capacitance. the corrosion reaction and diffusion effects, can be determined from empirical impedance data provided that a sufficient frequency range is investigated. This range may extend from a low limit of 10µHz to an upper frequency in the order of 1MHz, depending on the process being studied. The low frequency region can provide information concerning charge transfer and diffusion phenomena and the high frequency part defines the solution resistance. As a practical example, it has been shown that the corrosion behaviour of coated metals can be described by corrosion reactions at the metal/coating interface, defined by low frequency measurements and, at high frequencies, the capacitive behaviour of the intact coating layer. An additional effect, due to penetration of the electrolyte, gives rise to a resistive component, which may be determined from intermediate and low frequency data. a 1-10 BTR006

Conclusions Measurement of ac impedance data is a powerful tool for the analysis of corroding systems, particularly where these are highly resistive. The technique may be applied to investigate a wide range of electrochemical phenomena, including corrosion and surface treatments, battery testing, biological and photoelectric effects. Correlation frequency response analysis, using single sine stimulation of the system and measurement of the resultant current and voltage, via a potentiostat, enables accurate and repeatable determination of the response, in spite of low signal levels, high noise levels and the presence of non-linear reactions. It should be noted, however, that while the FRA is most commonly used for this type of investigation, researchers are studying broad-band stimulation and spectral analysis. Although the results are not as accurate and signal-to-noise ratios are not generally good, there can be a time saving using this method and it cannot, therefore, be ignored. This note is intended only to be a basic introduction to electrochemical impedance measurement. Further (more detailed) technical reports are available. Bibiliography Other Technical Reports on Impedance Analysis and Electrochemistry available from Solartron: Identification of Electrochemical Processes by Frequency Response Analysis (C Gabrielli, Technical Report No. 4) Frequency Response Analysis (P E Wellstead, N D Cogger, R V Webb, Technical Report No. 10) The Measurement of Signals from Electrochemical Phenomena (N D Cogger, Technical Report No. 14) Understanding Electrochemical Cells (A Kauffman, Technical Report No. 17) Use and Applications of Electrochemical Impedance Techniques (C Gabrielli, Technical Report No. 24) Analysis and Interpretation of EIS Data for Metals and Alloys (F Mansfield, Technical Report No. 26) Applications of EIS to Cementitious Systems (W J McCarter, Technical Report No. 29) EIS for Battery Research and Development (T C Lo, Technical Report No. 31) The Potentiodynamic Polarization Scan (D G Enos/L L Scribner, Technical Report No. 33) BTR006 1-11