Product Catalogue. Relays with forcibly guided contacts



Similar documents
Elesta Elektrotechnik AG industry relays and accessories

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

40 Series - Miniature PCB/Plug-in relays A. Features

Pluggable interface relays CR-P Pcb relays

Goodsky Technical Data. Contact Details

SKR - industry relay

48 SERIES Relay interface modules 10 A

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

49 Series - Relay interface modules A. Features

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

RY2 miniature industrial relays

38 Series - Relay interface modules A

38 Series - Relay interface modules A

SPST-NO SPDT DPST-NO DPDT

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

E-STOP relays, safety gate monitors

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

1 POLE - 8A Medium Load Control

FP2 Relay. The Best Relaytion

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

Safety technique. Emergency stop module BO 5988 safemaster

RELAYS Solar Energy Systems

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Safety automation solutions

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

Optocoupler, Phototransistor Output, AC Input

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

MasterINTERFACE 39 Series - Relay interface modules

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

1 POLE - 5A SLIM POWER RELAY

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

SPST-NO SPDT DPST-NO DPDT

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

60 Series - General purpose relays 6-10 A. Features

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

1 Form A Solid State Relay

E-STOP relays, safety gate monitors

RM4TG20 three-phase network control relay RM4-T - range V

Type: DILM50(230V50HZ,240V60HZ) Article No.:

1a/1c 5A/10A small power relays

Type: DILM9 10(24VDC) Article No.:

E-STOP relays, safety gate monitors

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Type: DILM32 10(24V50HZ) Article No.:

Optocoupler, Phototransistor Output, with Base Connection, 300 V BV CEO

Contact expander modules

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Thermal-Magnetic Circuit Breaker M1-..

E-STOP relays, safety gate monitors

CQM1-SF200/CS1W-SF200

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

HERZ-Thermal Actuators

CompactLogix Power Supplies Specifications

AXICOM Telecom-, Signal and RF Relays. Cradle Relay S V23054 / V Nov. 07 Rev. C ECOC: JM10

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Contact expansion modules

MasterINTERFACE 39 Series - Relay interface modules

CONFIGURABLE SAFETY RELAYS

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

NX safety stand-alone

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Relays and Timers Specifications Bulletin Number 700

w BREAKING CAPACITY W EMPLOYMENT 1) Locking function description

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

1 Form A Solid State Relay

E-STOP relays, safety gate monitors

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

Features. Applications. Truth Table. Close

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Trip circuit supervision relay. Type RXTCS

AZ420 MINIATURE GENERAL PURPOSE RELAY

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

DS 600. A contact free flux gate based current measurement sensor 600A rms

CONFIGURABLE SAFETY RELAYS

Electro-pneumatic control valves

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Transcription:

Product Catalogue Relays with forcibly guided contacts

Product Catalogue - Relays with forcibly guided contacts Edition / Publisher: ELESTA relays GmbH, Bad Ragaz, Switzerland All rights reserved. This work and its parts are protected by copyright. Any use in other than legally authorized cases requires the prior written consent of the publisher.

The comp ELESTA relays GmbH was founded in 997 as a producer of relays with forcibly guided contacts, but our roots date back to the middle of the last century. Since then, relays have been designed and manufactured in Bad Ragaz in the Swiss canton of St. Gallen. The distinctive feature of these electromechanic relays is the special contact set compliant with EN 55. All contacts are interlinked in such a way that NC contact and NO contact must never be closed simultaneously, even in case of a fault. Relays with forcibly guided contacts are primarily used in control units for functional safety applications, and therefore wherever life and health of people need to be protected. Through the use of relays with forcibly guided contacts load and monitoring circuits can easily be linked together in safety controls. High diagnostic coverage and reliability are characteristics that predestine these relays for use in machine and plant construction as well as in process technology, medical equipment, elevator controls or railway technology, to name just a few applications. 7 relay series with to contacts form the basis for a large number of variants, covering switching currents from ma to A as well as excitation voltages of up to. Owing to the use of advanced materials and newly developed contact systems our relays guarantee superior system vers and carefully selected materials support the eco-friendly control design. are tailored to the requirements of our customers. The possibilities range from simple coil adjustments to encoded sets of contacts with special relay drivers. This includes variants that are geared towards compliance with certain stan- (railway applications). These individual solutions are developed in close dialogue with the customer. In doing so, customers can, of course, depend on Innovation is our impetus. A wealth of experience and continuous training, close cooperation with research institutions and suppliers, as well as active participation in technical and standardization bodies enables us to implement new technologies and market requirements in forward-looking products early on. The entire comp of Elesta relays GmbH follows the LEAN principle. Clear structures are evident not only in our Green Factory (which does not require fossil fuels) but also in our operations (for which we often set higher standards than is required by EN ISO 9:). High product quality, supply readiness and service quality are the three pillars on which the comp rests. At the same time they are the guiding principles our employees identify with. The deployment of relays with forcibly guided contacts requires trust; a responsibility that we readily accept. Harald Förster Geschäftsführer / CEO ELESTA relays GmbH ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /

Product Overview Relays with forcibly guided contacts Relays SIS SIS SIS sen SIS SIS SIF SIF SIF SIR SIR sen Features Number of Contacts Contact Material Type of Contact Coil Voltage Small dimensions High shock resistance Large excitation voltage Low coil power loss High switching reliability Very small dimensions High shock resistance Large excitation voltage Very high switching reliability Very small dimensions High shock resistance Large excitation voltage Low coil power loss High switching reliability High shock resistance Large excitation voltage Low coil power loss Very high switching reliability Very small dimensions High shock resistance Large excitation voltage Very high switching reliability Available by end of design Large switching current range Possible component installation under the relay design Large switching current range Possible component installation under the relay Classic CO relay Extrusioncoated coil design suitable for use in ATEX areas Classic CO relay Low coil power loss Extrusioncoated coil design suitable for use in ATEX areas SGR Z Classic CO relay Extrusioncoated coil design suitable for use in ATEX areas CO CO CO CO SGR Z sen Classic CO relay Low coil power loss Extrusioncoated coil design suitable for use in ATEX areas AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgSnO AgSnO AgCuNi AgCuNi Notched crown Notched crown Notched crown Notched crown Notched crown Notched crown Notched crown Notched crown Single contact Single contact 5 - Single contact Single contact Coil 7mW mw mw 5mW mw mw 7mW mw mw 7mW mw 7mW Capacity Switching Current Range Test Voltage Open Contact Test Voltage between Contacts Test Voltage Coil/ Contact ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5 Veff Veff Veff Veff Veff Veff Veff Veff Veff Veff Veff Veff 5Veff 5Veff 5Veff Veff (SIS) 5Veff (SIS) Not for new new wd designs will bee replaced placed ed by y SGR R ZK 5Veff Veff Veff Veff 5 Veff 5 Veff 5 Veff 5 Veff Protection RT RT RT RT RT (external) in mm L 9. W. H.5 L 9. W. H.5 L 9. W. H.5 L W. H.5 L W. H.5 L.7 W 9. H.9 L W 9. H.9 L 5. W.5 H.9 L. W.7 H 5. L. W.7 H 5. L. W.7 H 5. L. W.7 H 5. Options (see catalogue) UL, cul, TÜV - - - - - - - - page page page page page page 5 page page 7 page available late page 9 page page page page page Reference temperature C Between left and right contact side 5 Between control and output contacts Between control contacts Between output contacts Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

Product Overview Relays with forcibly guided contacts SGR ZK SIM SIM SIM SLR SIR SIR sen SIR P SIR SIR sen SIR SIR SIP Extrusioncoated coil design suitable for use in ATEX areas Very high switching reliability Extrusioncoated coil design suitable for use in ATEX areas High switching reliability Extremely high leakage and creepage distances Extrusioncoated coil design suitable for use in ATEX areas High switching reliability Extremely high leakage and creepage distances Extrusioncoated coil design suitable for use in ATEX areas High switching reliability Extremely high leakage and creepage distances Powerful Small, horizontal design Large switching current range High switching reliability Powerful Small design High switching reliability Powerful Small design High switching reliability Low coil power loss Wide coil working range Extremely powerful Small design For loads with a high surge current High switching reliability Powerful Small design High switching reliability Contact assignment Powerful Small design High switching reliability Low coil power loss Wide coil working range Contact assignment Powerful High switching reliability Wide coil working range Contact assignment Powerful High switching reliability Wide coil working range Contact assignment Extremely powerful High switching reliability For the highest loads during -phase applications and DC loads CO AgCuNi AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO Notched crown Crest contact Crest contact Crest contact Crest contact Crest contact Crest contact Single contact Crest contact Crest contact Crest contact Crest contact Single contact 7mW 5mW 75mW mw mw mw mw 75mW 75mW 5mW mw mw mw ma - A ma - A ma - A ma - A ma - A ma - A ma - A 5mA - A ma - A ma - A ma - A ma - A 5mA - A 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff Veff Veff 5Veff Veff 5Veff Veff Veff Veff 5 5 Veff 5Veff 5 Veff 5 Veff 5Veff 5 Veff 5 Veff 5Veff 5 Veff 5 Veff 5Veff 5 Veff 5 Veff 5Veff 5 Veff 5 Veff Veff Veff 5Veff 5 Veff 5 Veff 5 Veff 5 Veff 5 Veff 5 Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5 Veff 5Veff 5Veff L. W.7 H 5. L 7. W.5 H. L. W.5 H. L. W.5 H. L 5. W. H.5 L. W H.7 L. W H.7 L. W H.7 L 5.9 W H.7 L 5.9 W H.7 L 5.5 W H L 5.5 W H L. W H UL, cul, TÜV page - page 9 page 9 - page page page page page - - - page 5 page page 7 page page 9 page page page page page page 5 page page 7 ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /

SIS Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS NO / NC - Small external dimensions - Mean coil power.7 W - Holding coil power. W - For railway application (EN555) on request.5 ±..... 9.....7 Ø...... 5 7.7. 9. Contact Data...... AgCuNi+.-.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) Min. pick-up voltage at C Drop-out voltage at C Resistance in Ohm at C 5 5.9 9 ± %. ± % 9.5 95 ± %. 5 ± % 5. ± %. ± % 5.7 5 ± %.5 ± 5% A SIS A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically 5ms Shock resistance ms NO > 7g NC > 7g NO > 7g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIS Contact Lifetime for NO Contacts Operations x 5 5 5 DC : V AC :V AC 5: V DC : V..5 5 79 Maximal switching characteristics(en97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIS Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS NO / NC - Small external dimensions - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request.5 ±.... 9. 5....5.. Ø......5.5 7.7. 9...... Contact Data AgCuNi+.-.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5..5 ± % 9. 5 ± % 5. ± %. 5 ± % 5. 9 ± %.5 ± %. ± % 5. 5 ± 5% A SIS A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically 5ms Shock resistance ms NO > 7g NC > g NO > 7g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIS Contact Lifetime for NO contacts Operations x 5 5 5 DC : V AC :V AC 5: V DC : V..5 5 79 Maximal switching characteristics (DIN EN97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each...... 5 5 5 ) Inductive load L/R ms ) Resistive load Operations x..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 5

SIS sensitive Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS NO / NC - Small external dimensions - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request.5 ±.... 9. 5....5.. Ø......5.5 7.7. 9...... Contact Data AgCuNi+.-.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5..5 ± %. 9 ± % 9.5 ± %. ± %. ± %. ± %. 5 75 ± %. 9 ± 5% A A SISSEN - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance 5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically 5ms Shock resistance ms NO > 7g NC > g NO > 7g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIS SEN sensitive coil Contact Lifetime for NO Contacts Operations x 5 5 5 DC : V AC :V AC 5: V DC : V..5 5 79 Maximal switching characteristics (DIN EN97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIS Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact Mounting: SIS NO / NC SIS NO / NC - Small external dimensions - Mean coil power.5 W - Holding coil power.5 W - For railway application (EN555) on request.5 ±....5 ±.... SIS..5.7.5...5.5.7.. SIS..7 5. Ø... 5.7 5. Contact Data Ø. 7... AgCuNi+.-.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5.5 5 ± % 9. 5. ± %.. 5 ± %.. ± %.. 5 ± %.. ± %.. 7 ± % 77..5 ± 5% A SIS A A SIS - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically 5ms typically 5ms typically ms typically 5ms Shock resistance ms NO > g NC > g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIS A Contact Lifetime for NO Contacts Operations x 5 5 5 DC : V AC :V AC 5: V DC : V..5 5 79 Maximal switching characteristics (DIN EN97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each contacts with A each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 7

SIS Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS NO / NC - Small external dimensions - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request.5 ±........5.5..5 5 7..5.5.5 Contact Data.5 Ø..7.. AgCuNi+.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C 5 at C 5.5 7.5 ± % 9. 7.7 ± %. 55. 5 ± %. 7. 5 ± %. 9.7 ± %..9 5 ± %.. 5 ± % 77.. ± 5% 5 5 A SIS - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically 5ms typically 5ms typically ms typically 5ms Shock resistance ms NO > g NC > 9g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. 5g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available A Contact Lifetime for NO Contacts Operations x 5 5 5 DC : V AC :V AC 5: V DC : V..5 5 79 Maximal switching characteristics (DIN EN97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each contacts with A each contacts with A each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIS Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIF Series - Protective separation between coil and contacts (>5.5mm) and contacts side by side (>5.5mm) - EN55 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact Mounting: SIF NO / NC - Compact height: only.9mm - Mean coil power.7 W - Holding coil power. W - For railway application (EN555) on request.9.9.5 7. 7. 5.....5 5. 7.5 7.5 7.5...... 7. Ø.. 5.. 5..5... * Do not drill when SMD arrangement ** Open breathing hole. 9.... Contact Data AgCuNi+.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C 5. 7.5 ± % 5.5 5 ± % 9. ± % 5. 57 ± % 9. ± %. ± %.7 5 ± %. 7 5 ± 5%.. A SIF A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically 5ms typically.5ms typically 5ms Shock resistance ms NO > 5g NC > g NO > g (-Hz) NC > g Resistance to short circuiting NO A SCPD A gg/gl (pre-fuse) Resistance to short circuiting NC A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIF Contact Lifetime for NO Contacts Operations x AC 5: V DC : V AC :V DC : V..5. 5. Maximal switching characteristics (DIN EN 97-5-) AC : 5V / A AC 5: V / 5A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each contacts with A each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 9

SIF Series - Protective separation between coil and contacts (>5.5mm) and contacts side by side (>5.5mm) - EN55 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact mounting: SIF NO / NC - Compact height: only.9mm - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request.9.9..5... 5. 7.. 5. 5. 5. * * * Ø. *..... * Do not drill when SMD arrangement ** Open breathing hole...5.5..5.. Contact Data AgCuNi+.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) 5. 7.5 7.5 at C C at C 5. 7.5 ± % 55. 5 ± %.9 ± %. ± % 7.5 7 ± %. ± %. 5 ± %. ± 5% 5 A 5 SIF A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically ms typically.5ms typically 5ms Shock resistance ms NO > g NC > g NO > g (-Hz) NC > g Resistance to short circuiting NO A SCPD A gg/gl (pre-fuse) Resistance to short circuiting NC A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 7K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIF Contact Lifetime for NO Contacts Operations x AC 5: V DC : V AC :V DC : V..5. 5. Maximal switching characteristics (DIN EN 97-5-) AC : 5V / A AC 5: V / 5A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each contacts with A each contacts with.5a each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIR Series will be replaced by SGRZK - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts - Mean coil power W - Holding Power.W..7 SIR A A Contact Lifetime for NO Contacts Operations x AC :V AC 5: V AC : V DC : V DC : V..5. 5..7. 5 5 Contact Data 5 5...5/.5 Ø.. 7.5 AgSnO +.μm Au Type of contact Single contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C 5.75. 7.5 ± %.5. ± % 9. 5.7 ± %.5. 7 ± %.. 7 ± %.. ± % 5. ± %.5. ± 5% - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 55 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Sealed RT on request Dust resistant with O-Ring Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / 5A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each Current (A)..... Not otf for or new new wd designs gns. 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIR O-ring dust-resistant ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /

SIR sensitive Series will be replaced by SGRZK - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts - Mean coil power approx..7w - Holding coil power.w - For railway application (EN555) on request.7. 5 5. Contact Data 5 5...5/.5 Ø..7. 7.5 AgSnO +.μm Au Type of contact Single contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C 5.75..7 ± %.5. 5 ± % 9.. ± %.5. 5 ± %.. ± %. 5. ± % 5. 5 ± %.5.5 ± 5% A SIRSEN A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Sealed RT on request Dust resistant with O-Ring Contact Lifetime for NO Contacts Operations x Not tfo or new wd design gns AC :V AC 5: V AC : V DC : V DC : V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / 5A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each...... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load Current (A)..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIR SEN O-ring dust-resistant sensitive coil Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SGR Z Series will be replaced by SGRZK - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts - Mean coil power W - Holding coil power.w.7. 5 5. Contact Data 5 5...5/.5 Ø..7. 7.5 AgCuNi Type of contact Single contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A * ma to A Switching capacity range* mw to 5W(VA) Switching capacity range** mw to 5W(VA) at C C at C 5.75. 7.5 ± %.5. ± % 9. 5.7 ± %.5. 7 ± %.. 7 ± %.. ± % 5.. ± %.5. ± 5% A SGRZ A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 55 Pollution degree >5x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Sealed RT on request Dust resistant with O-Ring SGRZ AU O-ring dust resistant Contact Lifetime for NO Contacts Operations x DC :V AC :V AC 5:V DC :V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each Gold contacts with - m layer thickness When switching high voltages and currents the layer of gold is already destroyed after a few switching operations. Once the gold layer is damaged due to the switching of high loads, this contact must not be used more for signal and control current circuits. Then safe contact making is only possible at high loads with the formation of sparks. Operations x..... Not otfo for or new ewd designs gns. 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /

SGR Z sensitive Series will be replaced by SGRZK - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts - Mean coil power.7w - Holding coil power.w.7. 5 5. Contact Data 5 5...5/.5 Ø..7. 7.5 AgCuNi Type of contact Single contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A * ma to A Switching capacity range* mw to 5W(VA) Switching capacity range** mw to 5W(VA) at C C at C 5.75..7 ± %.5. 5 ± % 9.. ± %.5. 5 ± %.. ± %. 5. ± % 5.. 5 ± %.5.5 ± 5% A SGRZ SEN A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 55 Pollution degree >x operations 5Hz typically ms typically 5ms ct typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Sealed RT on request Dust resistant with O-Ring SGRZ SEN AU O-ring dust resistant sensitive Spule Contact Lifetime Operations x DC :V AC :V AC 5:V DC :V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each Gold contacts with - m layer thickness When switching high voltages and currents the layer of gold is already destroyed after a few switching operations. Once the gold layer is damaged due to the switching of high loads, this contact must not be used more for signal and control current circuits. Then safe contact making is only possible at high loads with the formation of sparks. Operations x..... Not otf for forn new ewd designs gns. 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SGR ZK Series - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts with notched crown - Mean coil power.7w - Holding Power.W.7. 5 5. Contact Data 5 5...5/.5 Ø..7. 7.5 Type of contact notched crown Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* 5mW to W(VA) at C C at C 5.75. 5.7 ± %.5. 5. ± % 9. 5.5 5 ± %.5.9 ± %. 9. ± %..5 9 ± % 5.. 5 ± %.5. 7 ± 5% A SGRZ A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 55 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC >.5g Resistance to short circuiting NO A SCPD A gg/gl (pre-fuse) NC A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Various modules on request Contact Lifetime for NO Contacts Operations x AC :V AC 5: V DC : V AC : V DC : V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each...... 5 5 5 ) Inductive load L/R ms ) Resistive load Operations x..5..5..5 ) Max. excitation voltage with contact load: <A ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SGRZK ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 5

SIM Series - PCB Relay with forcibly guided Contacts - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type A - Contact mounting: SIM NO / NC - Small external dimensions - Mean coil power.5w - Holding coil power.5w.9...5 7.5.5. 7... 5.9 5.9 Contact Data 5 5.7.7 Ø..5.5.5 7.5.5 AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C 5.5. 5 ± %. 5.7 7 ± %.. 7 ± %.7. ± %.. ± %..9 ± %..7 5 ± 5% 77. 5.5 ± 5% A SIM A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIM Contact Lifetime Operations x AC :V DC : V AC 5: V DC : V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC : 5V / A AC 5: V / A DC : / A DC : V / A /.Hz UL 5: C5 / R...... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load Current (A)..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIM Series - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type A - Contact mounting: SIM NO / NC - Small external dimensions - Mean coil power.75w - Holding coil power.w - For railway application (EN 555) on request.9...5 7.5.5..5 7.5.5.... 5.9 5 5 5..5.5 7.5.5 Ø. Standard Contact Data 5.9 5 5 5. 5.9 5 5 5. Ø. KV.5 AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C 5.75 5. ± %.5 5. ± % 9.. 9 ± % 5.75 5.5 59 ± %.. ± %. 5. ± % 5..5 ± %.5. ± 5% Variant : Standard A SIM A Variant : KV A SIM - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V A PCB socket, DIN rail socket see page 9 SIM Contact Lifetime Operations x AC :V DC : V AC 5: V DC : V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC : 5V / A AC 5: V / A DC : V / A DC : V / A /.Hz UL 5: C5 / R Maximal contact load at AC with V: contacts with A each...... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load Current (A)..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 7

SIM Series - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type A - Contact mounting: SIM NO / NC SIM NO / NC - Small external dimensions - Mean coil power W - Holding coil power.9w.9...5 7.5.5.... 5.9 5 5 5..5.5 7.5.5 Ø. Contact Data 5.9 5 5 5..5 AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C 5.75. 7.5 ± %.5. ± % 9. 5.7 ± % 5.75. 5 ± %.. ± %.. ± % 5.. ± %.5 9. ± 5% SIM A A A SIM A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resitance CTI 5 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page 9 SIM Contact Lifetime Operations x AC :V DC : V AC 5: V DC : V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC : 5V / A AC 5: V / A DC : V / A DC : V / A /.Hz UL 5: C5 / R Maximal contact load at AC with V: contacts with A each contacts with A each...... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load Current (A)..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SLR Series - Protective separation between coil/control contacts (>mm) as well as protective separation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SLR NO / NC SLR NO / NC - Small external dimensions - Mean coil power.w - Holding coil power.w - Coils for railway applications (EN 555) on request.9.5 5 5..9...5 Ø. 5...7.. Component Side.9.5..7. Contact Data...7.. AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA).7.7.7 at C C at C 5.5. ± %.. ± %. 5. ± %.. 5 ± %. 5. 95 ± %.. ± %.. ± % 77. 5.5 ± 5% SLR A A A SLR A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > g NC > g NO > 5g (-Hz) NC >.5g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available Contact Lifetime Operations x AC :V DC : V AC 5: V DC : V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SLR ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 9

SIR Series - Protective separation between coil/control contacts (>mm) as well as protective separation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR NO / NC - Small external dimensions - Mean coil power.w - Holding coil power.w - Coils for railway applications (EN 555) on request.7.9.9.9. 5.5 5 Contact Data. 5.5 5 Ø..7 AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5.5. ± %.. ± %. 5. ± %.. 5 ± %. 5. 95 ± %.. ± %.. ± % 77. 5.5 ± 5% A SIR A A SIR A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > g NC > g NO > 5g (-Hz) NC >.5g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIR Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIR sensitive Series - Protective separation between coil/control contacts (>mm) as well as protective seperation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR NO / NC - Small external dimensions - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request.7.9.9.9. 5.5 5 Contact Data. 5.5 5 Ø..7 AgSnO +.μm Au Type of contact Crest Contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5.75 7. 9. ± %.5. ± % 9.75. 5 ± % 9.. ± %.5. 9 ± %. 5. ± %. 7.5 ± % 5.. ± 5% SIRSEN SIRSEN A A A A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resitance CTI 5 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resitance ms NO > g NC > g NO > 5g (-Hz) NC >.5g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page SIR SEN sensitive coil Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V..5. 5. Maximal switching characteristics (DIN EN97-5-, Tab.C) AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load AC with V: contacts with A each contacts with.a each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) ( contacts) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /

SIR Power Series - Protective separation between coil/control contacts and output contacts (>mm) and output contacts side by side (>mm) - EN55 type A - Contact mounting: SIRP Control contacts NO / NC Output contacts NO SIRP Control contacts NC Output contacts NO - Inrush current A / continuous current A - Mean coil power.75 W - Holding coil power. W - For railway application (EN555) on request.7.9.9.9. 5.5 5. Control Contacts 5.5 5 Ø..7 AgSnO +.μm Au Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC 5mA to A Switching capacity range* mw to 5W(VA) Output Contacts AgSnO Rated switching capacity 5VAC (VAC) A AC VA Electr. life AC ( cycles/h) approx.5 A for ms 5 to 5 ( VAC) ma to A Switching capacity range* mw to W(VA) at C C at C 5 5. ± %. 9 ± %. ± % 7.7 5 ± %.5 7 ± % 5.7 5 ± %.5 ± %. ± 5% Output Contacts Control Contacts A SIRP A A SIRP - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > 7g NC > 7g NO > g (-Hz) NC >.5g Resistance to short circuiting control contacts A SCPD A gg/gl (pre-fuse) Resistance to short circuiting output contacts A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page SIR P Power version A Contact Lifetime (output contacts) DC Operations x DC : V DC : V DC : V 5 Contact Lifetime (output contacts) AC Operations x AC : V AC : V AC : V AC 5: V AC : V 5 Maximal contact load AC with V: contacts with A each Operations x...... 5 5 5 ) Inductive load L/R ms ) Resistive load..5..5..5 ) Max. excitation voltage with contact load: ) Min. excitation voltage (guaranteed values) without Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIR Series - Protective separation between coil/control contacts and output contacts (>mm) as well as protective separation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR NO / NC SIR5 5NO / NC - Small external dimensions - Mean coil power.75 W - Holding coil power. W - For railway application (EN555) on request.7.9 5.9.9. 5.5 5 7.5 5 Ø..9 Contacts Data 5.5 5 7.5 5.7 AgSnO +.μm Au Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5.5 5. ± %. 5. ± %.. 9 ± %.. ± %..5 7 ± %. 5.7 5 ± %..5 ± % 77.. ± 5% 5 5 SIR 5 5 SIR 5 5 SIR5 A A A A A A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > g NC > g NO > 5g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page SIR Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V..5. 5. Max. switching characteristics (DIN EN 97-5-, Tab. C): AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each contacts with 7.A each 5 contacts with A each Current (A)...... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /

SIR sensitive Series - Protective separation between coil/control contacts and output contacts (>mm) as well as protective separation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR NO / NC SIR5 5NO / NC - Small external dimensions - Mean coil power.5 W - Holding coil power. W - For railway application (EN555) on request.7.9 5.9.9. 5.5 5 7.5 5 Ø..9 Contacts Data 5.5 5 7.5 5.7 AgSnO +.μm Au Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5.75. 5 ± %.5. 7 ± % 9.75 5. ± % 9.. ± %.5 7.7 ± %.. 5 ± %.. ± % 5.. 7 ± 5% 5 5 SIRSEN 5 5 SIRSEN 5 5 SIR5SEN A A A A A A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resitance CTI 5 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resitance ms NO > g NC > g NO > 5g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page SIR SEN Sensitive coil Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V..5. 5. Max. switching characteristics (DIN EN 97-5-, Tab. C): AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each contacts with 7.A each 5 contacts with A each Current (A)...... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load..5..5..5 ) ( contacts) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIR Series - Protective separation between coil and output contacts (>mm) and contacts in one row (>mm) as well as protective separation between left and right contact side (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR5 NO /5NC SIR NO / NC SIR5 5NO /NC SIR NO / NC SIR7 7NO /NC - Small external dimensions - Mean coil power. W - Holding coil power.9 W - For railway application (EN555) on request.9.75.5.75 5.5. 7.9 57.5 57.557.55. Contacts Data 7.9 57.557.5 57.5 5..5.75 Ø...5.75 AgSnO +.μm Au Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C.. 7.5 ± %. 9. ± %. 7. 5 ± %. 5.5 ± %. 7. 7 ± %.. 75 ± % 77.. 9 5 ± % 5. 5.9 7 ± 5% 7 7 5 5 7 7 5 5 7 7 5 5 SIR SIR5 SIR A A A A A A 7 7 5 5 7 7 5 5 7 7 5 5 SIR5 SIR SIR7 A A A A A A - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > g NC > g NO > g (-Hz) NC >.5g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance K/W Temperature limit for coil 5 C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V..5. 5. Max. switching characteristics (DIN EN 97-5-, Tab. C): AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each contacts with 7.A each 5 contacts with.5a each contacts with A each Current (A)...... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIR 5 ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 5

SIR Series - Protective separation between coil/control contacts and output contacts (>mm) and output contacts in one row (>mm) as well as protective separation between left and right contact side (>mm) - EN55 type A - Contact mounting: SIR7 NO / 7NC SIR7 7NO /NC SIR NO / NC SIR NO /NC SIR55 5NO / 5NC SIR9 9NO /NC SIR NO / NC - Mean coil power. W - Holding coil power.9 W - For railway application (EN555) on request.9.75.5.75 5.5. 5. 57.557.557.557.55. 5. 57.557.557.557.5 5. Contacts Data.5.75 Ø...5.75 AgSnO +.μm Au Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C.. 7.5 ± %. 9. ± %. 7. 5 ± %. 5.5 ± %. 7. 7 ± %.. 75 ± % 77.. 9 5 ± % 5. 5.9 7 ± 5% 9 9 9 9 9 9 9 9 7 7 7 7 7 7 7 7 5 5 5 5 5 5 5 5 SIR7 SIR SIR55 SIR A A A A A A A A 9 9 9 9 9 9 7 7 7 7 7 7 5 5 5 5 5 5 SIR7 A A SIR A A SIR9 A A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC > g NO > g (-Hz) NC >.5g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance K/W Temperature limit for coil 5 C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIR 5 5 Contact Lifetime Operations x AC : V AC 5: V DC : V DC : V..5. 5. Max. switching characteristics (DIN EN 97-5-, Tab. C): AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each contacts with 7.A each 5 contacts with.5a each contacts with A each contacts with 5A each 9 contacts with.a each Current (A)...... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load..5..5..5 ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

SIP Series - Protective separation between coil/control contacts and output contacts (>mm) and output contacts in one row (>mm) - EN55 type A - Contact mounting: SIP5 Control contacts NO / NC Output contacts NO SIP Control contacts NC Output contacts NO - High switching power - Mean coil power. W - Holding coil power.9 W - For railway application (EN555) on request.9.75.75.5.. 5.. 5.5 5.5 5.5 5.5 5.. 5. 5.5 5.5 5.5 5.5 5. Control Contact Ø..75.5.75.5.5.5.5 AgSnO +.μm Au Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC 5mA to A Switching capacity range* mw to 5W(VA) Output Contact AgSnO Rated switching capacity 5VAC (VAC) A AC VA Electr. life AC ( cycles/h) approx.5 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C.. 7.5 ± %. 9. ± %. 7. ± %. 5.5 ± %. 7. 7 ± %.. 75 ± % 77.. 9 5 ± % 5. 5.9 7 ± 5% 5 5 5 5 Output Contacts Control Contacts SIP 5 SIP A A A A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC > g NO > g (-Hz) NC > 5g Resistance to short circuiting control contacts A SCPD A gg/gl (pre-fuse) Resistance to short circuiting output contacts A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance K/W Temperature limit for coil 5 C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIP Contact Lifetime (output contacts) DC Operations x DC : V DC : V DC : V 5 Contact Lifetime (output contacts) AC Operations x AC : V AC : V AC : V AC 5: V AC : V 5 UL 5: A / R5 Maximal contact load at AC with V: contacts with A each contacts with A each contacts with A each.... 5 5 5 Voltage () ) Inductive load L/R ms ) Resistive load Current (A)..5..5..5 ) Max. excitation voltage with contact load: ) Min. excitation voltage (guaranteed values) without ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 7

Relay Accessories for Series SGR Z, SIR, SGR ZK PCB socket SRP-SGR DIN rail socket SRD-SGR Modules for SRD-SGR Socket data - With plastic hold down clip - for PCB -.5mm pinning Socket data - With plastic grip and marking tag ( pc) - Screw terminals -.5mm pinning - Assembly on DIN rail 5mm or single-hole mounting with M screw Module SRD-SGR-M - For DIN rail socket SRD-SGR - Diode to (+ on terminal A) A + A Module SRD-SGR-M - For DIN rail socket SRD-SGR - Diode with red LED, to (+ on terminal A) Module SRD-SGR-M - For DIN rail socket SRD-SGR - Diode with green LED, to (+ on terminal A) A +. A.. 9..5. 5 Modul SRD-SGR-M - For DIN rail socket SRD-SGR - Red LED, to (+ on terminal A) Modul SRD-SGR-M5.7 - For DIN rail socket SRD-SGR - Green LED, to (+ on terminal A) A +. Ø.5 5.5 COM NO 7.5 75 COIL A A NC A Technical data Rated current xa Rated voltage VAC Test voltage coil/contacts Veff Insulation class (IEC -) 5VAC Creepage resistance CTI 5 approx. g - C to +7 C Packing unit pcs UL, cul UL File E7 Technical data Rated current xa Rated voltage VAC Test voltage coil/contacts 5Veff Insulation class (IEC -) 5VAC Creepage resistance CTI 5 approx. g -5 C to +7 C Cross sections for connection with wires x.5mm end sleeves for strands x.5mm Maximales Drehmoment.Nm Packing unit pcs UL, cul UL File E7 Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

Relay Accessories for Series SIM and SIM Print socket SRP-SIM Socket data - With integrated retaining/ejector handels - for PCB DIN rail socket SRD-SIM Socket data - With integrated retaining/ejector handels - Screw terminals - Assembly on DIN rail 5mm or with xm screws 5.9 7. / /.5.. 5 5 5 Ø.5 7.5.7 SA-SIM ELESTA 75. A A.5 SRD-SIM (SIM...) SRD-SIM (SIM...) A A A A Technical data Rated current A Rated voltage 5VAC Test voltage coil/contacts Veff Insulation class (IEC -) 5VAC Creepage resistance CTI 5 approx. g -5 C to +7 C Packing unit pcs UL, cul UL File E97 Technical data Rated current A Rated voltage 5VAC Test voltage coil/contacts 5Veff Insulation class (IEC -) 5VAC Creepage resistance CTI 5 approx. 5g -5 C to +7 C Cross sections for connection with wires x.5mm end sleeves for strands x.5mm Maximales Drehmoment.Nm Packing unit pcs UL, cul UL File E97 ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 9

Relay Accessories for Series SIR and SIR Print socket SRP-SIR Print socket SRP-SIR Socket data - PCB socket for SIR contacts - With integrated retaining/ejector handels - for PCB Socket data - PCB socket for SIR contacts - With integrated retaining/ejector handels - for PCB.5.7..5.7 5.5 5 Ø.5 5 7.5 5.5 5 7. Ø.5. 57 9. 9.5 9. Technical data Rated current A Rated voltage 5VAC Test voltage coil/contacts Veff Insulation class (IEC -) 5VAC Creepage resistance CTI 5 approx. 5g -5 C to +7 C Packing unit pcs UL, cul UL File E97 Technical data Rated current A Rated voltage 5VAC Test voltage coil/contacts Veff Insulation class (IEC -) 5VAC Creepage resistance CTI 5 approx. 7g -5 C to +7 C Packing unit pcs UL, cul UL File E97 Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

Notes ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /

Notes Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5

Switzerland: ELESTA relays GmbH Phone: + () 5 Heuteilstrasse Fax: + () 5 CH-7 Bad Ragaz E-Mail: admin@elestarelays.com Switzerland Internet: www.elestarelays.com Germ: ELESTA relays GmbH Phone: +9 () 77 5 Vertriebsbüro Frankfurt Fax: +9 () 77 57 Grabenstrasse 5 E-Mail: admin@elestarelays.com D-5 Seligenstadt Internet: www.elestarelays.com Germ ELESTA relays GmbH Phone: +9 () 9 7 Vertriebsbüro Leipzig Fax: +9 () 9 5 99 Unterer Haselberg E-Mail: admin@elestarelays.com D- Naunhof Internet: www.elestarelays.com Germ Worldwide: see www.elestarelays.com Your ELESTA relays partner: ELESTA relays GmbH en / _