Power System Harmonics



Similar documents
Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers

Neutral Currents in Three Phase Wye Systems

Product Data Bulletin

Survey of Harmonics Measurements in Electrical Distribution Systems

Harmonics in your electrical system

DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT

Survey of Harmonics Measurements in Electrical Distribution Systems

Introduction. Harmonics and IEEE 519 Page 1 of 19

Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution

EET272 Worksheet Week 9

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

415V DISTRIBUTION FOR GREEN DATA CENTERS

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

any electrical system depends upon knowledge, preventive maintenance and subsequently the test equipment used to monitor that system.

HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

BALANCED THREE-PHASE CIRCUITS

415V DISTRIBUTION FOR GREEN DATA CENTERS

7-41 POWER FACTOR CORRECTION

Three phase circuits

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

Standards of Power Quality with reference to the Code of Practice for Energy Efficiency of Electrical Installations

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Interpreting IEEE Std 519 and Meeting its Harmonic Limits in VFD Applications

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Application Guide. Power Factor Correction (PFC) Basics

Harmonic Distortion and Variable Frequency Drives

3-Phase AC Calculations Revisited

Specifying a Variable Frequency Drive s

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

Current and Temperature Ratings

The Basics of Digital Multimeters

Power System Harmonic Fundamental Considerations: Tips and Tools for Reducing Harmonic Distortion in Electronic Drive Applications

FREQUENCY CONTROLLED AC MOTOR DRIVE

Power Quality Standards for Electric Service

Analysis of AC-DC Converter Based on Power Factor and THD

Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a

Three-phase AC circuits

PHASE CONVERSION TECHNOLOGY OVERVIEW

DATA CENTER POWER SYSTEM HARMONICS: AN OVERVIEW OF EFFECTS ON DATA CENTER EFFICIENCY AND RELIABILITY

Scholars Research Library

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

How To Wire A Three Phase, Single Phase, Wye Transformer

21 st Century Facilities

How To Improve Power Quality

Performance of 3-Phase 4-Wire Solid State Transformer under Imbalanced Loads

CONTROL OF HARMONICS IN ELECTRICAL POWER SYSTEMS

Paralleling Power Sources Which Share a Common Neutral

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Line Reactors and AC Drives

Avoiding AC Capacitor Failures in Large UPS Systems

Chapter 12: Three Phase Circuits

How To Limit Voltage Unbalance

Harmonic Reduction and Load Balancing of Three Phase Four Wire DSTATCOM using Three Leg VSC and a Zig Zag Transformer

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

ECONOMIC AND ELECTRICAL BENEFITS OF HARMONIC REDUCTION METHODS IN COMMERCIAL FACILITIES

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Metering Devices IQ Analyzer 6400/6600 Series

Three-Phase AC Power Circuits

How To Balance Three Phase Power In A Balanced System

TRANSFORMER: THREE PHASE

LOW-VOLTAGE three-phase four-wire electrical distribution

Power Quality. Uninterruptible Power Supply

Measurement of Adjustable Speed Drives with Fluke Meters

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

Power Quality Analysis and Evaluation at Water Pumping Station Supplied by Medium Voltage

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Chapter 4: Power Factor Correction

Module Title: Electrotechnology for Mech L7

Principles of Adjustable Frequency Drives

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

HARMONICS AND HOW THEY RELATE TO POWER FACTOR. W. Mack Grady The University of Texas at Austin Austin, Texas 78712

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

GUIDE FOR TESTING POWER TRANSFORMERS

Power Supplies. 1.0 Power Supply Basics. Module

Electronics. Basic Concepts. Yrd. Doç. Dr. Aytaç GÖREN Yrd. Doç. Dr. Levent ÇETİN

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Electromagnetic Compatibility (EMC) Low-Frequency Standards. Standards on Low-Frequency Emission: IEC

Motor Protection Voltage Unbalance and Single-Phasing

VOLTAGE REGULATOR AND PARALLEL OPERATION

Voltage Unbalance and Motors

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Control of a 3-phase 4-leg active power filter under non-ideal mains voltage condition

AC Generators. Basic Generator

Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17

Chapter 4 AC to AC Converters ( AC Controllers and Frequency Converters )

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Chapter 24. Three-Phase Voltage Generation

How To Understand And Understand The Theory Of Electricity

Chapter 12 Three-Phase Circuit

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Transcription:

Pacific Gas and Electric Company Power System Harmonics What are power system harmonics? Ideally, voltage and current waveforms are perfect sinusoids. However, because of the increased popularity of electronic and other non-linear loads, these waveforms quite often become distorted. This deviation from a perfect sine wave can be represented by harmonics sinusoidal components having a frequency that is an integral multiple of the fundamental frequency (see Figure 1). Thus, a pure voltage or current sine wave has no distortion and no harmonics, and a nonsinusoidal wave has distortion and harmonics. To quantify the distortion, the term total harmonic distortion (THD) is used. The term expresses the distortion as a percentage of the fundamental (pure sine) of voltage and current waveforms. Distorted waveform (60 Hz = Fundamental + 3rd Harmonic) Fundamental (60 Hz) 3rd Harmonic (180 Hz) Figure 1: Distorted Waveform Composed of Fundamental and 3 rd Harmonic. THD approximately 30% Why are voltage and current harmonics a problem? Current harmonics are a problem because they cause increased losses in the customer and utility power system components. Transformers are especially sensitive to this problem and may need to be derated to as much as 50% capacity when feeding loads with extremely distorted current waveforms (current total harmonic distortion above 100%). 1

ANSI/IEEE C57.110-1986 (IEEE Recommended Practice for Establishing Transformer Capacity When Supplying Nonsinusoidal Load Currents) states that a transformer subject to nonsinusoidal load current having more than 5% total harmonics distortion needs to be derated. However, when current THD is below 15%, the derating of the transformer would be so small that it can be neglected. On the other hand, when current THD exceeds 15%, the transformer capability should be evaluated by a professional using IEEE recommendations. It is important to clarify that these IEEE recommendations do not apply to transformers especially designed to feed nonsinusoidal loads. Underwriters Laboratories (UL) tests and rates this special type of transformer, also called a K-factor transformer. Loads with highly distorted current waveforms also have a very poor power factor; because of this, they use excessive power system capacity and could be a cause of overloading. Voltage source electronic adjustable speed drives (ASD) often have a total power factor 1 of approximately 65% because of the highly distorted current. This total power factor could be corrected to approximately 85% using line-side chokes (reactors) on the drive. The chokes limit the rate of rise and the peak value of the line current, dramatically reducing the current THD. In addition, current harmonics can distort the voltage waveform and cause voltage harmonics. Voltage distortion affects not only sensitive electronic loads but also electric motors and capacitor banks. In electric motors, negative sequence harmonics (i.e. 5 th, 11 th, 17 th ), so called because their sequence (ABC or ACB) is opposite of the fundamental sequence (see Figure 2), produce rotating magnetic fields. These fields rotate in the opposite direction of the fundamental magnetic field and could cause not only overheating but also mechanical oscillations in the motor-load system. A 5th Harmonic C 5th Harmonic B 5th Harmonic A B C Figure 2: Balanced 3-Phase voltage with 5 th harmonic. Note the inverted sequence of the 5 th harmonic. 1 Defined by kw divided by KVA, not the cosine of the angle between the fundamental of the voltage and the fundamental of the current which is close to unity on ASDs and often advertised by vendors. 2

The problem with capacitor banks, on the other hand, is that the reactance (impedance) of a capacitor bank decreases as the frequency increases 2. This causes the bank to act as a sink or trap for higher harmonic currents from the surrounding customer and/or utility system. The effect is increased current, increased heating and dielectric stresses that could lead to capacitor bank failure. Single-phase load harmonics vs. three-phase load harmonics Single-phase non-linear loads, like personal computers, electronic ballasts and other electronic equipment, generate odd harmonics (i.e. 3 rd, 5 th, 7 th, 9 th, etc.). The troublesome harmonics for single-phase loads are the 3 rd and odd multiples of the 3 rd (9 th, 15 th, etc.). These harmonics are called triplens and because the A-phase triplen harmonics, B-phase triplen harmonics and C-phase triplen harmonics are all in the phase with each other. They will add rather than cancel on the neutral conductor of a 3-phase 4-wire system. This can overload the neutral if it is not sized to handle this type of load. Additionally, triplen harmonics cause circulating currents on the delta winding of a delta-wye transformer configuration. When current triplen harmonics on the neutral of a 3-phase 4-wire system reach the transformer, they are reflected to the deltaconnected primary where they circulate. The result is transformer heating similar to that produced by unbalanced 3-phase current. On the other hand, 3-phase non-linear loads like 3-phase ASDs, 3-phase DC drives, 3-phase rectifiers, etc., for not generate current triplen harmonics (3 rd, 9 th, 15 th, etc.). These types of loads generate primarily 5 th and 7 th current harmonics and a lesser amount of 11 th, 13 th, and higher order. How do you check for harmonic currents? When non-linear loads are a considerable part of the total load in the facility (more than 20%), there is a chance of a harmonics problem. Another consideration is the amount of current distortion produced by the non-linear loads. Electronic ballasts, for example, come with current THD ranging from 6% to 100%. It is important to avoid electronic ballasts with more than 20% current THD. PWM 3 ASDs typically produce close to 100% current THD, which can be reduced to less than half by installing inexpensive 3% impedance line-side reactors (chokes). Another important way to check for harmonic currents is to measure the current in the neutral of a 3-phase 4-wire system. If the neutral current is considerably higher than the value predicted from the imbalance in the phase currents, there is a good possibility of heavy presence of triplen harmonics. Other signs of current harmonics include inexplicable higher-than-normal temperatures in the transformer, voltage distortion and high crest factor. 2 Harmonics have higher frequency than the fundamental (60Hz); the 5 th harmonic, or example, has a frequency of 300 HZ. 3 Pulse Width Modulation is the most common technology used in ASDs under 200HP. 3

What is crest factor? The crest factor of any waveform is the ratio of the peak value to the RMS value. 4 In a perfect sine wave, the crest factor is 1.414. Crest factors different than 1.414 indicate distortion in the waveform. Typically distorted current waveforms have crest factors higher than 1.414 (see Figure 3), and distorted voltage waveforms have crest factors lower than 1.414. Distorted voltage waveforms with crest factors lower than 1.414 are called flat top voltage waveforms. Figure 3. Typical current waveform for a single-phase non-linear load with a switched-mode power supply. This kind of waveform is characterized by high crest factors, usually between 2.2 and 3.0 The Computer and Business Equipment Manufacturers Association (CBEMA) recommends a method for derating transformers based on the current crest factor. CBEMA defines the transformer harmonic-derating factor (THDF) as the ratio of 1.414 to the transformer current crest factor. The derated KVA of the transformer would be the nominal KVA of the transformer multiplied by the THDF. This method, however, should only be applied when the distortion in the current is caused by single-phase, non-linear loads (like personal computers) and other office equipment. Also, when using this method, the crest factor measurements should always be made in the secondary of the transformer. A more complete method for transformer derating is the one described by ANSI/IEEE C57.110-1986. What kind of equipment is needed to measure distorted waveforms? A digital oscilloscope is needed to measure the wave shape, THD and amplitude of each harmonic. However, if we simply want to measure the RMS value of the waveform, a True-RMS multimeter will suffice. The term True-RMS is used because not all instruments give correct readings when measuring distorted waveforms. The majority of low-cost portable instruments are average responding-rms calibrated. These instruments give correct readings for distortion-free sine waves and will typically read low when the current waveform is distorted. Most portable instruments with true RMS capabilities are labeled or listed as such in their owner manuals. 4 Typically when we measure voltage and current, we are measuring RMS values. 4

Does having harmonics in the power system always mean trouble? Harmonics only mean trouble if the power system is not designed to handle them. High harmonic neutral currents are a problem only if the neutral is not properly sized. Current harmonics are not a problem to a transformer if it is derated appropriately. Even some voltage distortion below 8% THD at the point of utilization) is acceptable as long as sensitive equipment is not affected. However, it is always important to be aware of the presence of harmonics and to try to minimize them by purchasing low distortion electronic ballasts and reactors for PWM ASDs. This will not only keep the harmonics in check and improve the power factor in the facility, but will also save energy by reducing losses on power system components. In addition, any time there is a considerable increase of non-linear loads, it is important to check power system components to prevent problems. Revised: January 1993 5