LOW-VOLTAGE three-phase four-wire electrical distribution
|
|
|
- Jonathan Gordon
- 10 years ago
- Views:
Transcription
1 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 54, NO. 4, AUGUST Analysis and Control of a Single-Phase-Inverter Zigzag-Transformer Hybrid Neutral-Current Suppressor in Three-Phase Four-Wire Systems Sewan Choi, Senior Member, IEEE, and Minsoo Jang Abstract This paper presents analysis and control of a hybrid filter that can suppress neutral harmonic currents in three-phase four-wire systems not only with harmonic voltage source loads but also with harmonic current source loads. The filter voltampere rating is significantly reduced compared to the conventional neutral-current-suppressing methods. The rectifier part of the neutral harmonic suppressor has been removed by controlling the dc capacitor voltage. The experimental results on a 50-kVA prototype validate the proposed control approach. Index Terms Active filter, neutral current, three-phase four-wire, zero-sequence, zigzag transformer. I. INTRODUCTION LOW-VOLTAGE three-phase four-wire electrical distribution systems have been widely employed to deliver electric power to single-phase and/or three-phase loads in manufacturing plants and commercial and residential buildings. The most common loads that are connected to the distribution system are nonlinear and include computer systems, uninterrupted power systems, adjustable-speed heating ventilation and air-conditioning systems, electronic and magnetic ballasts, photocopiers, etc. Nonlinear loads result in significant neutral current in the three-phase four-wire system since triplen odd harmonics in phase currents do not cancel each other even under balanced condition and are added up in the neutral line. In many cases, the neutral current exceeds the phase current. Under the worst case, the neutral current could be 1.73 times the phase current [1]. Excessive neutral currents may cause wiring failure of the neutral conductor, overloading of the distribution transformer, and a voltage drop between the neutral and the ground. Recently, an analysis has been performed to investigate the effect of unbalanced supply voltage and background voltage harmonics on the phase and neutral-current harmonics in the three-phase four-wire system [2]. Several methods have been proposed to reduce the neutralcurrent harmonics [3] [15]. A passive zigzag transformer, which is shunt connected to the load, is designed to have a low zero-sequence impedance, allowing the zero-sequence neutral Manuscript received January 10, 2006; revised March 6, The authors are with the Department of Control and Instrumentation Engineering, Seoul National University of Technology, Seoul , Korea ( [email protected]). Digital Object Identifier /TIE currents to circulate from the neutral back to the load [3] [5]. This requires special design of the transformer for low zerosequence impedance, and therefore, the size and weight of the zigzag transformer become significant. Therefore, the effectiveness of eliminating the neutral current is strongly dependent on the unknown system impedance, and the reduction rate may not be satisfactory in an installation location that is far from the load. Three-phase four-wire active power filters employing a four-leg inverter [6], [7] or a three-leg inverter with [8], [9] and without [10], [11] split capacitors could be used to mitigate the neutral current. These schemes are also capable of compensating line current harmonics, reactive power, and line current unbalancing. However, the schemes are complicated in control and high in cost. Single-phase series active filters [12], [13], which are connected in series with the neutral conductor, have been proposed to suppress the neutral current. These schemes are simple in configuration and control. However, analysis and control of the scheme in [12] is valid only for balanced condition, and the scheme in [13] may need to sacrifice ridethrough capability by flat topping of line voltages to achieve sufficient neutral-current elimination. A harmonic suppression scheme that is proposed in [14] employs a Y transformer, along with a single-phase inverter that is connected in parallel with the load. This scheme does not need a special design of the transformer unlike the passive zigzag transformer, and therefore, the magnetic could be smaller in size and weight. This is because the single-phase pulsewidth modulation (PWM) inverter is operated to help the zero-sequence neutral harmonics flow through the transformer back to the load. The effectiveness of eliminating the neutral current does not depend on the system impedance, and reduction rate is higher than 90% in any installation location. This paper presents analysis and development of a hybrid neutral harmonic suppressor, which was introduced in [15], that employs a zigzag transformer that is connected in parallel with the load and a single-phase inverter that is connected in series with the neutral conductor. The rectifier part of the neutral harmonic suppressor has been removed by controlling the dc capacitor voltage. In addition to the aforementioned advantages of the scheme that is proposed in [14], which are smaller magnetic and higher reduction rate without regard to the installation location, the proposed scheme demonstrates significant reduction in the required voltampere rating of the inverter due to /$ IEEE
2 2202 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 54, NO. 4, AUGUST 2007 Fig. 2. Proposed hybrid filter system. Fig. 1. Neutral-current waveform and frequency spectrum. (a) Balanced load condition. (b) Unbalanced load condition. the series connection of the inverter. Furthermore, the proposed scheme is shown to have good compensation characteristics with both harmonic current source loads (inductive loads) and harmonic voltage source loads (capacitive loads). A new control method is provided such that only the harmonics in the neutral current are suppressed, while the fundamental current due to unbalanced loading remains unaffected by operation of the proposed hybrid filter. II. PROPOSED SCHEME A. Operating Principles In three-phase four-wire systems, neutral current is the algebraic sum of three phase currents. Three phase currents with balanced and linear loads sum to zero; thus, there is no neutral current in this case. However, nonlinear loads such as power supplies and rectifiers have phase currents that are not sinusoidal. As shown in (1) (4), the algebraic sum of three balanced and nonsinusoidal phase currents does not sum to zero, i.e., i La = I 1 sin ωt + I 3 sin 3ωt + I 5 sin 5ωt + (1) i Lb = I 1 sin(ωt 120 )+I 3 sin 3(ωt 120 ) + I 5 sin 5(ωt 120 )+ (2) i Lc = I 1 sin(ωt )+I 3 sin 3(ωt ) + I 5 sin 5(ωt )+ (3) i nl =3I 3 sin 3ωt +3I 9 sin 9ωt +3I 15 sin 15ωt +. (4) In particular, the zero-sequence triplen odd harmonics (third, ninth, fifteenth, etc.) do not cancel each other in the neutral conductor, thus resulting in excessive neutral current, as shown in Fig. 1(a). Meanwhile, neutral current resulting from unbalanced and nonlinear loads consists of not only the harmonic zero-sequence components but also the fundamental zero-sequence component, which should remain unaffected. Fig. 1(b) shows a typical neutral current waveform and its frequency spectrum with 26.8% of unbalance factor (UBF). The voltage UBF that is defined in European standards is used in this paper as an index of the degree of unbalance. In percentage value, it is expressed as UBF = Negative Sequence Magnitude Positive Sequence Magnitude 100(%). (5) Fig. 2 shows the power circuit of the proposed scheme that employs a zigzag transformer that is connected in parallel with the load and a single-phase PWM inverter that is connected in series with the neutral conductor. A bypass switch is placed in parallel with the inverter and will be operated in case of inverter failure. Let us first consider the operation with the bypass switch to be closed, i.e., with only the zigzag transformer connected to the load. All the zero-sequence currents that are generated in the load-side neutral circulate via the zigzag transformer back to the load and do not appear in the supply-side neutral if the zero-sequence impedance of the zigzag transformer is negligible compared to the source impedance. However, if it is not, the effectiveness of circulating the zero-sequence currents to the load via the zigzag transformer could not be satisfactory. Now, the bypass switch is opened to connect the inverter in series with the neutral conductor. Proper inverter operation increases the effectiveness of circulating the zero-sequence currents to the load via the zigzag transformer. Therefore, the effectiveness does not depend on the zero-sequence impedance of the zigzag transformer and hence the installation location of the proposed filter system. Special design of the zigzag transformer for low zero-sequence impedance does not necessitate, and therefore, the size and weight of the zigzag transformer could become smaller for the proposed scheme. Meanwhile, load-side neutral current resulting from unbalanced and nonlinear loads consists of not only the harmonic
3 CHOI AND JANG: ANALYSIS OF SINGLE-PHASE-INVERTER ZIGZAG-TRANSFORMER NEUTRAL-CURRENT SUPPRESSOR 2203 zero-sequence components but also the fundamental zerosequence component that should remain unaffected. Therefore, only the zero-sequence harmonic currents are intended to flow via the zigzag transformer back to the load, and the zerosequence fundamental current flows through the supply-side neutral. There are two reasons only the harmonic currents are diverted into the zigzag transformer, not allowing the fundamental current to be diverted into it. Suppose that the loads are balanced and nonlinear. The zerosequence triplen odd harmonic currents that are generated in the load-side neutral, as shown in (4), are equally divided by three, are diverted into the zigzag transformer, and cancel the triplen odd harmonic load currents, resulting in improved input current total harmonic distortion (THD) as indicated in the following. Three phase currents in the zigzag transformer become i fa = i fb = i fc =1/3 i nl = I 3 sin 3ωt + I 9 sin 9ωt + I 15 sin 15ωt +. (6) Then, the triplen odd harmonics do not appear in the input source current, as shown in the following: i Sa = i La i fa = I 1 sin ωt + I 5 sin 5ωt + I 7 sin 7ωt + (7) i Sb = i Lb i fb = I 1 sin(ωt 120 )+I 5 sin 5(ωt 120 ) + I 7 sin 7(ωt 120 )+ (8) i Sc = i Lc i fc = I 1 sin(ωt )+I 5 sin 5(ωt ) + I 7 sin 7(ωt )+. (9) Meanwhile, if the fundamental component, which is generated on the load-side neutral under unbalanced loading, is allowed to divert into the zigzag transformer, it may be added to or subtracted from the fundamental load current, and the input current THD may become worse. Therefore, only the harmonic currents are diverted into the zigzag transformer, while the fundamental current is diverted into the inverter that is connected in series with the supply-side neutral. In the proposed scheme, the zigzag transformer could be rated considering only the harmonic currents, while the inverter could be rated considering only the fundamental current, resulting in reduced rating of both the zigzag transformer and the inverter. This is an advantage over the scheme [14], in which all the currents are intended to divert into the zigzag transformer and to the inverter. Therefore, both the zigzag transformer and the inverter should be rated considering the harmonic currents as well as the fundamental current. Fig. 3. Control block diagram. B. Proposed Control and Compensation Characteristics The control block diagram for the proposed system is shown in Fig. 3. The control can be divided into the following three parts: 1) current control for the fundamental; 2) voltage control for the harmonics; and 3) dc voltage control. 1) Current Control for the Fundamental: The current control aims at forcing the zero-sequence fundamental current that is generated by the unbalanced load into flowing through the supply-side neutral. In Fig. 3, G i (s) is a compensator for current control of the fundamental. The current reference for the fundamental component is given by I ns,f = G I nl. (10) The compensation characteristic for the fundamental component can be given by I ns,f I nl,f = G(s) = ω 0 Q s s 2 + ω 0 Q s + ω2 0 (11) where G(s) is the transfer function of the bandpass filter, ω o is the angular center frequency, and Q is the quality factor. The zero-sequence fundamental current that is generated on the load-side neutral under unbalanced loading is forced to flow into the supply-side neutral by this current control, which prevents the fundamental current from flowing through the zigzag transformer. 2) Voltage Control for the Harmonics: The voltage control aims at preventing the zero-sequence harmonic currents from flowing through the supply-side neutral. In Fig. 3, K h is a gain for voltage control of the harmonics. a) Harmonic current source load: The zero-sequence equivalent circuit for a pure harmonic current source load i nl is shown in Fig. 4 [17]. Here, Z S is the source impedance, and Z Z is the zero-sequence impedance of the zigzag transformer. The reference inverter output voltage for the harmonics is given by V f = K h (1 G) I ns = K h I ns,h. (12) If the harmonic equivalent resistance is K, the actual inverter output voltage can be expressed as V f = K I ns,h. (13)
4 2204 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 54, NO. 4, AUGUST 2007 Fig. 4. Zero-sequence equivalent circuit with a pure harmonic current source load. Fig. 6. Zero-sequence equivalent circuit with a pure harmonic voltage source load. Fig. 5. Compensation characteristics of Fig. 4 (K = 2.5 p.u.,zs = 0.02 p.u., and Q =6). The inverter is controlled in such a way as to act as a resistor with high resistance of K[Ω] for harmonic frequencies and to present zero impedance for the fundamental frequency harmonic equivalent resistance [18]. The harmonic equivalent resistance K in the single-phase full-bridge inverter can be defined by 1 K = K h V d (14) A T where A T is the peak amplitude of the triangular signal, and the inverter dc voltage is V d. Then, the supply-side neutral current can be expressed from Fig. 3 as Z z I ns = Z s + Z z + K(1 G) I nl. (15) The required operating condition of the PWM inverter in order to suppress the harmonic currents on the supply-side neutral is K Z Z. Fig. 5 shows the harmonic compensation characteristics of the supply-side neutral current with respect to the harmonic current source load in case of Z Z =0.02 p.u., Z Z =0.04 p.u., and Z Z =0.06 p.u.. The system parameters for the example calculation are assumed to be V PU = 220 V, P PU =16.6 kva, Z PU =2.92 Ω, and Z S =0.02 PU (0.058 Ω and L S =0.15 mh). Note that the magnitude gain at harmonic frequencies is sufficiently low even with considerably large zero-sequence impedances of the zigzag transformer, so that the zero-sequence harmonics that are generated on the load-side neutral are suppressed on the supply-side neutral. b) Harmonic voltage source load: The harmonic zerosequence equivalent circuit for a pure harmonic voltage source load V L can be shown in Fig. 6. Then, the supply-side neutral current can be expressed from Fig. 6 as I ns = 1 Z z + K (1 G) V L. (16) The required operating condition of the PWM inverter in order to suppress the harmonic currents on the supply-side Fig. 7. Compensation characteristics of Fig. 6 (K =2.92 p.u., Zz = 0.02 p.u., and Q =6). neutral is K 1 p.u., or Z S is large. Fig. 7 shows the harmonic compensation characteristics of the supply-side neutral current with respect to the harmonic voltage source load in case of Z S =0.02 p.u., Z S =0.04 p.u., and Z S =0.06 p.u. This illustrates that the zero-sequence harmonic currents that are generated from the harmonic voltage source load are well suppressed on the supply-side neutral, not depending on the source impedance. 3) DC Voltage Control: In the proposed scheme, it is not necessary to supply the real power from the zigzag transformer or another three-phase supply for the inverter since the dc capacitor voltage can be produced by inverse energy in the neutral, i.e., by controlling the dc voltage. As shown in Fig. 3, the voltage error between the measured and the reference is sent to a proportional integral controller, and the output is multiplied by the harmonic component of the supply-side neutral current to obtain the harmonic reference, which draws harmonic real power from the neutral for dc voltage regulation. Under balanced loading, the inverter output voltage V f and current i ns become zero since there will be no fundamental current on the load-side neutral in theory, and therefore, the real power that is drawn by the inverter is zero. However, in practice, there will be a small amount of harmonic currents on the supply-side neutral, which were not diverted into the zigzag transformer, resulting in nonzero real power that is drawn by the inverter. Furthermore, under unbalanced loading, there will be fundamental current both on the supply-side and load-side neutral. The inverter output current has only the fundamental, and the inverter output voltage has all the harmonics, except the fundamental. Therefore, the real power should be zero in theory. However, in practice, there will be some amount of harmonics in the inverter output current, and the inverter output voltage has a small magnitude of the fundamental. This also results in nonzero real power. Hence, owing to this nonideal operation, the inverter could draw a small amount of real power including the real power due to components power losses in the inverter. The dc capacitor voltage should be maintained at a desired value for proper inverter operation. The capacitance should
5 CHOI AND JANG: ANALYSIS OF SINGLE-PHASE-INVERTER ZIGZAG-TRANSFORMER NEUTRAL-CURRENT SUPPRESSOR 2205 Fig. 8. Simulated waveforms for balanced harmonic current source load. be designed not too high, so that the voltage control can be performed with a small amount of harmonic currents. If the harmonic currents are so low that proper dc voltage control cannot be maintained, the inverter will be deactivated by closing the bypass switch. In the proposed inverter, the required dc capacitor voltage is shown to be as low as 30 V in the 220-V LL system, and therefore, low-cost high-efficiency metal oxide semiconductor field-effect transistors with smaller R DS(ON) can be employed as a switching device. Very low magnitude of the fundamental and harmonic currents means that the loads are very light, or linear and balanced. For both cases, the filter inverter does not need to be activated; therefore, if the magnitude of the fundamental and harmonic currents goes below some specified level, the bypass switch across the inverter output is closed, and the inverter will be deactivated. After the deactivation, if the magnitude of the fundamental and harmonic currents goes above some other specified level, the bypass switch is opened, and the dc voltage will gradually build up (see Figs. 8 and 9 in Section II-C). C. Simulation Fig. 8 shows the simulated waveforms of the proposed scheme for balanced harmonic current source load. After the inverter starts to operate, the supply-side neutral current i ns becomes nearly zero since the zero-sequence triplen harmonics in the load-side neutral flow through the zigzag transformer and do not appear on the supply-side neutral conductor. The dc capacitor voltage is gradually increased and well regulated at a designed value. It can be seen that all the triplen harmonics are suppressed in source current i Sa since the zero-sequence triplen harmonics that are injected into the zigzag transformer cancel the zero-sequence triplen harmonic in the load phase current as well. Fig. 9 shows the simulated waveforms of the proposed scheme for unbalanced harmonic voltage source load. Before the inverter is started, the zero-sequence currents are generated under unbalanced loading flow not only into the zigzag transformer but also into the supply-side neutral. After the inverter is started, only the fundamental zerosequence current flows into supply-side neutral, and the harmonic zero-sequence currents flow through the zigzag transformer. D. Kilovoltampere Rating of the Inverter and Zigzag Transformer The kilovoltampere rating of the inverter switches is calculated as the product of the peak current and peak voltage. The peak current of the inverter switch can be obtained by considering only the fundamental zero-sequence of the load neutral current due to the unbalanced loading. Therefore, the current rating of the inverter switch of the proposed scheme is smaller than that of the scheme [14], where all the harmonic currents always flow through the inverter switches. The peak voltage rating of the inverter switch is equal to the dc capacitor voltage, which is determined by the inductance of filter inductor L f and the wave shape of the inverter output current [16]. The required dc voltage of the inverter is also smaller than that of the scheme [14] since the proposed inverter needs to shape only the fundamental current. The kilovoltampere rating of the zigzag
6 2206 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 54, NO. 4, AUGUST 2007 Fig. 9. Simulated waveforms for unbalanced harmonic voltage source load. TABLE I FUNDAMENTAL LOAD PHASE CURRENTS FOR SPECIFIED UNBALANCED FACTORS (IN PER UNIT) with respect to the values of the conventional scheme. It should be noted that the required voltampere rating of the proposed scheme is much smaller than that of the conventional one. TABLE II REQUIRED VOLTAMPERE RATING OF THE INVERTER AND TRANSFORMER transformer is calculated as the product of the rms voltage and the rms current that is associated with each of its winding. From many possible combinations of the three-phase load phase currents, several sets of three-phase load currents with some specified UBFs are chosen and listed in Table I for kilovoltampere rating calculation. The load phase currents are assumed to have typical waveforms like waveform i Sa in Fig. 9 before the inverter is started. The inverter and the zigzag transformer kilovoltampere ratings of the proposed scheme and the conventional scheme have been calculated, and the comparative results are shown in Table II, respectively, where the voltampere ratings of the inverter and zigzag transformer are normalized III. EXPERIMENT RESULT To demonstrate the validity of the proposed approach, the experiments have been performed with both harmonic voltage source load and harmonic current source load under certain conditions. The supply is 220 V LL 60 Hz, with Z s =0.35 mh. The H-bridge PWM inverter is operated at f sw =20kHz, with a filter inductor of L f =2mH. Kilowatt harmonic current source load: Three singlephase diode rectifiers are connected between each line and neutral. Each rectifier has an R L load of a 50-Ω resistor and a 10-mH inductor. Harmonic voltage source load of 50 kva: A total of 18 sets of switched-mode power supplies (SMPSs) has been used. Each SMPS has ratings of 220-V ac input, 48-V dc output, and 1.5-kW output power. A resistor of 1.6 Ω was used as a load for each SMPS. Six sets of SMPSs, which are connected in parallel, form a line-toneutral load. Fig. 10 shows the experimental waveforms on a three-phase balanced harmonic current source load. The load-side neutral current i nl contains the harmonic zero-sequence components, and the supply-side neutral current is nearly zero. Fig. 11 shows the experimental waveforms on a three-phase unbalanced harmonic voltage source load. The load-side neutral current i nl contains not only the harmonic
7 CHOI AND JANG: ANALYSIS OF SINGLE-PHASE-INVERTER ZIGZAG-TRANSFORMER NEUTRAL-CURRENT SUPPRESSOR 2207 Fig. 12. Photograph of the proposed hybrid filter for 50-kVA load. zero-sequence components, but also the fundamental zerosequence component, while the supply-side neutral current i ns contains only the fundamental zero-sequence component. Fig. 12 shows the photograph of the prototype of the proposed neutral harmonic suppressor for 50-kVA load. Fig. 10. Experimental waveforms for balanced harmonic current supply load. IV. CONCLUSION In this paper, a hybrid filter is proposed to suppress neutralcurrent harmonics in three-phafse four-wire electrical distribution systems. The proposed filter has advantages over the conventional schemes. The proposed filter demonstrates good compensation characteristics with inductive loads as well as capacitive loads. The voltampere rating of the inverter is significantly reduced compared to the conventional scheme that is proposed in [14]. Under unbalanced loading, only the harmonics are suppressed, while the fundamental remains unaffected. The effectiveness of suppressing neutral current is over 90% without the flat-topping effect of line voltages [13]. This also does not depend on the system impedance and/or the installation location. The size and weight of the zigzag transformer in the proposed scheme is significantly reduced compared to that in [3] [5]. Operating principles and control strategy along with compensation characteristics have been in detailed. The experimental results on a prototype validate the proposed control approach. Fig. 11. Experimental waveforms for unbalanced harmonic voltage supply load (UBF = 30%). REFERENCES [1] T. M. Gruzs, Power system problems from high harmonic neutral current, Comput. Technol. Rev., Winter [2] D. Paraiso, E. Ngandui, M. de Montigny, and P. Sicard, Characterization of neutral and line current harmonics in three-phase computer power systems, in Proc. IEEE IECON, 2005, pp [3] P. P. Khera, Application of zigzag transformers for reducing harmonics in the neutral conductor of low voltage distribution system, in Proc. IEEE IAS Conf. Rec, pp
8 2208 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 54, NO. 4, AUGUST 2007 [4] H.-L. Jou, J.-C. Wu, K.-D. Wu, W.-J. Chiang, and Y.-H. Chen, Analysis of zig-zag transformer applying in the three-phase four-wire distribution power system, IEEE Trans. Power Del., vol. 20, no. 2, pp , Apr [5] F. N. Belchior, J. F. V. Ferreira, J. C. Oliveira, R. Apolonio, and A. B. Vasconcellos, Three-phase electromagnetic filter for zero-sequence harmonics, IEEE Trans. Magn.,vol.42,no.9,pp ,Sep [6] S. Jain, P. Agarwal, and H. O. Gupta, Neutral current compensation and load balancing with fuzzy logic controlled active power filter, in Proc. IEEE ISIE Conf. Rec, pp [7] L. G. Franquelo, M. A. M. Prats, R. C. Portillo, J. I. L. Galvan, M. A. Perales, J. M. Carrasco, E. G. Diez, and J. L. M. Jimenez, Threedimensional space-vector modulation algorithm for four-leg multilevel converters using abc coordinates, IEEE Trans. Ind. Electron., vol. 53, no. 2, pp , Apr [8] A. A. Valdez, G. Escobar, R. E. Torres-Olguin, and M. F. Martinez- Montejano, A model-based controller for a three-phase four-wire shunt active filter with compensation of the neutral line current, in Proc. IEEE CIEP, 2006, pp [9] G. Chung, Anti-windup scheme to control DC voltage of three-phase four-wire active power filter, Trans. KIPE, vol. 8, no. 2, pp , Apr (in Korean). [10] H. Kim, Instantaneous power compensation theory in three-phase fourwire systems, Trans. KIPE, vol. 11, no. 2, pp , Apr (in Korean). [11] J. Kim and Y. Kim, Three-phase four-wire series active power filter control strategy for compensation of harmonics and reactive power based on direct compensating voltage extraction method, Trans. KIPE, vol. 9, no. 3, pp , Jun (in Korean). [12] S. Inoue, T. Shimizu, and K. Wada, Control methods and compensation characteristics of a series active filter for a neutral conductor, IEEE Trans. Ind. Electron., vol. 54, no. 1, pp , Feb [13] P. T. Cheng, C. C. Hou, and Y. F. Huang, Overload prevention, IEEE Ind. Appl. Mag., vol. 10, no. 6, pp , Nov./Dec [14] P. Enjeti and W. Shireen, Analysis and design of a new active power filter to cancel neutral current harmonics in three-phase four-wire electric distribution systems, IEEE Trans. Ind. Appl., vol. 30, no. 6, pp , Nov./Dec [15] S. Choi and M. Jang, A reduced-rating hybrid filter to suppress neutral current harmonics in three-phase four-wire systems, IEEE Trans. Ind. Electron., vol. 51, no. 4, pp , Aug [16] T. Thomas, K. Haddad, G. Joos, and A. Jaafari, Design and performance of active power filters, IEEE Ind. Appl. Mag., vol. 4, no. 5, pp , Sep./Oct [17] F. Z. Peng, Application issues of active power filters, IEEE Ind. Appl. Mag., vol. 4, no. 5, pp , Sep./Oct [18] H. Akagi, Active and hybrid filters for power conditioning, in Proc. IEEE ISIE Conf. Rec., 2000, vol. 1, pp. TU26 TU36. Sewan Choi (S 92 M 92 SM 04) received the B.S. degree in electronic engineering from Inha University, Incheon, Korea, in 1985, and the M.S. and Ph.D. degrees in electrical engineering from Texas Agricultural and Mechanical University, College Station, in 1992 and 1995, respectively. From 1985 to 1990, he was with Daewoo Heavy Industries as a Research Engineer. From 1996 to 1997, he was a Principal Research Engineer at Samsung Electro-Mechanics Company, Korea. In 1997, he joined the Department of Control and Instrumentation Engineering, Seoul National University of Technology, Seoul, Korea, where he is currently an Associate Professor. He directed a student team to design and build a 10-kW fuel cell inverter for residential applications. His research interests include three-phase power factor correction, power conversion technologies in renewable energy systems, and dc-dc converters for hybrid electric and fuel cell vehicles. Prof. Choi is an Associate Editor of the IEEE TRANSACTIONS ON POWER ELECTRONICS. He, together with his student team, received the First Place in the 2003 Future Energy Challenge Competition, which is sponsored by the U.S. Department of Energy. Minsoo Jang was born in Seoul, Korea. He received the B.S. degree and M.S. degree in power electronics from Seoul National University of Technology (SNUT), Seoul, Korea, in 2001 and 2003, respectively. He is currently a Leader of the SNUT Student Team. His work at the Department of Control and Instrumentation Engineering, SNUT involves the design of an active power filter and its DSP control. Mr. Jang was the recipient of the First Place Award from 2003 Future Energy Challenge Competition, which was sponsored by the U.S. Department of Energy.
How To Improve Power Quality
Power Quality Improvement Of Three Phase Four Wire Distribution System Using VSC With A Zig-Zag Transformer Sajith Shaik *, I.Raghavendar ** *(Department of Electrical Engineering, Teegala Krishna Reddy
How To Improve Power Quality
Neutral Current compensation in three phase four wire DSTATCOM using Three Leg VSC and a Zig Zag Transformer 1 Ramya A R, 2 T.M.Vasantha Kumar, 3 K.R.Mohan 1,2,3 Dept. of Electrical and Electronics Engineering
Harmonic Reduction and Load Balancing of Three Phase Four Wire DSTATCOM using Three Leg VSC and a Zig Zag Transformer
IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 05, 2015 ISSN (online): 2321-0613 Harmonic Reduction and Load Balancing of Three Phase Four Wire DSTATCOM using Three Leg
NEURO-FUZZY BASED POWER QUALITY IMPROVEMENTS IN A THREE PHASE FOUR WIRE DISTRIBUTION SYSTEM USING DSTATCOM
NEURO-FUZZY BASED POWER QUALITY IMPROVEMENTS IN A THREE PHASE FOUR WIRE DISTRIBUTION SYSTEM USING DSTATCOM E.Babu 1,R.Subramanian 2 1, Department of Electrical and electronics engg 2 Department of Electrical
Power System Harmonics
Pacific Gas and Electric Company Power System Harmonics What are power system harmonics? Ideally, voltage and current waveforms are perfect sinusoids. However, because of the increased popularity of electronic
Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers
Journal Journal of of Emerging Emerging Trends Trends in in Engineering Engineering and and Applied Applied Sciences Sciences (JETEAS) (JETEAS) 1 1 (1): (1): 72-78 72-78 Scholarlink Research Institute
MODELING AND SIMULATION OF A THREE-PHASE INVERTER WITH RECTIFIER-TYPE NONLINEAR LOADS
, pp. 7-1 MODELING AND SIMULAION OF A HREE-PHASE INERER WIH RECIFIER-YPE NONLINEAR LOADS Jawad Faiz 1 and Ghazanfar Shahgholian 2 1 School of Electrical and Computer Engineering, Faculty of Engineering,
Survey of Harmonics Measurements in Electrical Distribution Systems
Survey of Harmonics Measurements in Electrical Distribution Systems Leon M. Tolbert, Member, IEEE Oak Ridge National Laboratory* P.O. Box 28, Bldg Oak Ridge, TN 3783-6334 Alexandria, VA 2235-3862 Phone:
Control Strategy for Three Phase Shunt Active Power Filter with Minimum Current Measurements
International Journal of Electrical and Computer Engineering (IJECE) Vol.1, No.1, September 2011, pp. 31~ 42 ISSN: 2088-8708 31 Control Strategy for Three Phase Shunt Active Power Filter with Minimum Current
Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder
Robert W. Erickson University of Colorado, Boulder 1 1.1. Introduction to power processing 1.2. Some applications of power electronics 1.3. Elements of power electronics Summary of the course 2 1.1 Introduction
Control of a 3-phase 4-leg active power filter under non-ideal mains voltage condition
Available online at www.sciencedirect.com Electric Power Systems Research 78 (008) 58 73 Control of a 3-phase 4-leg active power filter under non-ideal mains voltage condition Mehmet Ucar, Engin Ozdemir
Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique
Grid Interconnection of Renewable Energy Sources Using Modified One-Cycle Control Technique NKV.Sai Sunil 1, K.Vinod Kumar 2 PG Student, GITAM University, Visakhapatnam, India. Asst.Professor, Department
Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution
Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution Nandita Dey, Dr.A.K.Chakraborty Lecturer, Electrical Engineering Department, Tripura University Suryamaninagar
How To Simulate A Multilevel Inverter
Neutral Point Potential Balance of Three Phase Three Level Diode Clamped Inverter BALAMURUGAN M GNANA PRAKASH M Dr.UMASHANKAR S School of Electrical Engineering School of Electrical Engineering School
IJESRT. Scientific Journal Impact Factor: 3.449 (ISRA), Impact Factor: 2.114 [633] [Choudhary, 3(12): December, 2014] ISSN: 2277-9655
IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Performance of Capacitor Supported SRF based DSTATCOM in Three-Phase Four-Wire Distribution System under Linear and Non-Linear
A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER
A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER 1 KARUNYA CHRISTOBAL LYDIA. S, 2 SHANMUGASUNDARI. A, 3 ANANDHI.Y 1,2,3 Electrical
A bidirectional DC-DC converter for renewable energy systems
BULLETIN OF THE POLISH ACADEMY OF SCIENCES TECHNICAL SCIENCES Vol. 57, No. 4, 2009 A bidirectional DC-DC converter for renewable energy systems S. JALBRZYKOWSKI, and T. CITKO Faculty of Electrical Engineering,
Novel Loaded-Resonant Converter & Application of DC-to-DC Energy Conversions systems
International Refereed Journal of Engineering and Science (IRJES) ISSN (Online) 2319-183X, (Print) 2319-1821 Volume 2, Issue 11 (November 2013), PP.50-57 Novel Loaded-Resonant Converter & Application of
Hybrid Power System with A Two-Input Power Converter
Hybrid Power System with A Two-Input Power Converter Y. L. Juan and H. Y. Yang Department of Electrical Engineering National Changhua University of Education Jin-De Campus, Address: No.1, Jin-De Road,
Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1
Experiment no 1 Power measurement in balanced 3 phase circuits and power factor improvement 1 Power in Single Phase Circuits Let v = m cos(ωt) = cos(ωt) is the voltage applied to a R-L circuit and i =
POWER QUALITY ISSUES IN A STAND-ALONE MICROGRID BASED ON RENEWABLE ENERGY
POWER QUALITY ISSUES IN A STAND-ALONE MICROGRID BASED ON RENEWABLE ENERGY IOAN ŞERBAN, CORNELIU MARINESCU Key words: Microgrid (MG), Power quality, Dump load, Frequency control. The paper presents several
Three phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
An Efficient AC/DC Converter with Power Factor Correction
An Efficient AC/DC Converter with Power Factor Correction Suja C Rajappan 1, K. Sarabose 2, Neetha John 3 1,3 PG Scholar, Sri Shakthi Institute of Engineering & Technology, L&T Bypass Road, Coimbatore-62,
New Control Strategy To Improve Power Quality Using A Hybrid Power Filter
New Control Strategy o Improve Power Quality Using A Hybrid Power Filter S. P. Litrán, P. Salmerón, R. S. Herrera, and J. R. Vázquez Department of Electrical Engineering Escuela Politécnica Superior, University
Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies
Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager
Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager Introduction There is a growing trend in the UPS industry to create a highly efficient, more lightweight and smaller UPS
Survey of Harmonics Measurements in Electrical Distribution Systems
Survey of Harmonics Measurements in Electrical Distribution Systems Leon M. Tolbert, Member, EEE Oak Ridge ational Laboratory* P.O. Box 8, Bldg Oak Ridge, T 3783-6334 Alexandria, VA 35-386 Phone: (43)
A new approach for three-phase loads compensation based on the instantaneous reactive power theory
Available online at www.sciencedirect.com Electric Power Systems Research 78 (8) 65 617 A new approach for three-phase loads compensation based on the instantaneous reactive power theory Patricio Salmerón,
HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM
Technical Note No.3 March 2000 HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM This Technical Note discusses harmonic distortion, its causes and adverse effects, what levels are unacceptable and how
Modulation Strategies For Three Phase Inverters Supplying Unbalanced Three Phase Loads
ISSN (Online) : 9-875 ISSN (Print) : 47-67 International Journal of Innovative Research in Science, Engineering and Technology Volume, Special Issue, March 4 4 International Conference on Innovations in
FOUR LEGGED ACTIVE POWER FILTER COMPENSATION FOR A UTILITY DISTRIBUTION SYSTEM
Journal of LCTRICAL NGINRING, VOL. 55, NO. -, 4, 5 FOUR LGGD ACTIV POWR FILTR COMPNSATION FOR A UTILITY DISTRIBUTION SYSTM Abdelaziz Chaghi Amor Guettafi Azzedine Benoudjit This paper presents a four-leg
Line Current Characteristics of Three-Phase Uncontrolled Rectifiers Under Line Voltage Unbalance Condition
IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 17, NO. 6, NOVEMBER 2002 935 Line Current Characteristics of Three-Phase Uncontrolled Rectifiers Under Line Voltage Unbalance Condition Seung-Gi Jeong, Member,
Analysis of AC-DC Converter Based on Power Factor and THD
Website: www.ijetae.com (SSN 50-459, SO 900:008 Certified Journal, Volume 3, ssue, February 03) Analysis of AC-DC Converter Based on Power Factor and THD Shiney.S.Varghese, Sincy George Department of Electrical
Bridgeless PFC Implementation Using One Cycle Control Technique
Bridgeless PFC Implementation Using One Cycle Control Technique Bing Lu Center for Power Electronics Systems Virginia Polytechnic Institute and State University 674 Whittemore Hall Blacksburg, VA 24061
Product Data Bulletin
Product Data Bulletin Power System Harmonics Causes and Effects of Variable Frequency Drives Relative to the IEEE 519-1992 Standard Raleigh, NC, U.S.A. INTRODUCTION This document describes power system
Neutral Currents in Three Phase Wye Systems
POWER SYSTEMS ENGINEERING DATA PUBLISHED BY SQUARE D, OSHKOSH, WISCONSIN Subject: Neutral Currents in Three Phase Wye Systems by Robert Arthur Square D Company Oshkosh, Wisconsin (414) 46-80 and R. A.
Three leg VSC Based DSTATCOM and T-Connected Transformer for Power Quality Improvement
International Journal of Applied Sciences, Engineering and Technology Vol. 0, No. 0, Jan-Dec 0 Three leg VSC Based DSTATCOM and T-Connected Transformer for Power Quality Improvement G. KEERTHANA and S.
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES WHITE PAPER: TW0062 36 Newburgh Road Hackettstown, NJ 07840 Feb 2009 Alan Gobbi About the Author Alan Gobbi Alan Gobbi
A COMPERATIVE PERFORMANCE ANALYSIS OF BRIDGELESS PFC BOOST CONVERTER WITH THE CONVENTIONAL CONVERTER
A COMPERATIVE PERFORMANCE ANALYSIS OF BRIDGELESS PFC BOOST CONVERTER WITH THE CONVENTIONAL CONVERTER Shantiswaroop Agarwal 1, Pooja Gautam 2, Gaurav Kumar Sharma 3, Manoj Kumar Bhardwaj 4 1,2,3,4 Institute
EET272 Worksheet Week 9
EET272 Worksheet Week 9 answer questions 1-5 in preparation for discussion for the quiz on Monday. Finish the rest of the questions for discussion in class on Wednesday. Question 1 Questions AC s are becoming
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka S S B Udugampala, V Vijayarajah, N T L W Vithanawasam, W M S C Weerasinghe, Supervised by: Eng J Karunanayake, Dr. K T M U Hemapala
POWER QUALITY IMPROVEMENT OF GRID INTERCONNECTION WITH RENEWABLE ENERGY SOURCES AT DISTRIBUTION LEVEL
POWER QUALITY IMPROVEMENT OF GRID INTERCONNECTION WITH RENEWABLE ENERGY SOURCES AT DISTRIBUTION LEVEL G. Srinivas 1, D. Rajababu 2 1 PG student [PE&ES], Department of EEE, SR Engineering College, Telangana
POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS
A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS By: Robert G. Ellis, P. Eng., Rockwell Automation Medium Voltage Business CONTENTS INTRODUCTION...
DC/DC BUCK Converter for Renewable Energy Applications Mr.C..Rajeshkumar M.E Power Electronic and Drives,
DC/DC BUCK Converter for Renewable Energy Applications Mr.C..Rajeshkumar M.E Power Electronic and Drives, Mr.C.Anandaraj Assistant Professor -EEE Thiruvalluvar college of Engineering And technology, Ponnur
Introduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
A Novel Three-Phase Active Power Filter
Rev. Energ. Ren. : Power Engineering (2001) 7784 A Novel ThreePhase Active Power Filter University of Wales, Swansea, UK Abstract The performance and dynamic characteristics of a threephase threewired
MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS
MICRO HYDRO POWER PLANT WITH INDUCTION GENERATOR SUPPLYING SINGLE PHASE LOADS C.P. ION 1 C. MARINESCU 1 Abstract: This paper presents a new method to supply single-phase loads using a three-phase induction
Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor
International Journal of Innovation and Scientific Research ISSN 2351-8014 Vol. 11 No. 2 Nov. 2014, pp. 445-449 2014 Innovative Space of Scientific Research Journals http://www.ijisr.issr-journals.org/
Chapter 24. Three-Phase Voltage Generation
Chapter 24 Three-Phase Systems Three-Phase Voltage Generation Three-phase generators Three sets of windings and produce three ac voltages Windings are placed 120 apart Voltages are three identical sinusoidal
A bidirectional, sinusoidal, high-frequency inverter design
A bidirectional, sinusoidal, high-frequency inverter design E.Koutroulis, J.Chatzakis, K.Kalaitzakis and N.C.Voulgaris Abstract: A new method for the design of a bidirectional inverter based on the sinusoidal
MULTI-LEVEL INVERTER WITH DC LINK SWITCHES FOR RENEWABLE ENERGY SOURCES
VOL., NO. 8, OCTOBER 25 ISSN 89-668 26-25 Asian Research Publishing Network (ARPN). All rights reserved. MULTI-LEVEL INVERTER WITH DC LINK SWITCHES FOR RENEWABLE ENERGY SOURCES Sangari A., Umamaheswari
The Grid Interconnection of Renewable Energy at Distribution Level with the Features of High Power-Quality Improvement
The Grid Interconnection of Renewable Energy at Distribution Level with the Features of High Power-Quality Improvement Surendar Nagarapu 1, Shaik Khamuruddin 2, and Durgam. Kumara Swamy 3 1 M.Tech, Scholar
Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application
Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application A.Thiyagarajan Assistant Professor, Department of Electrical and Electronics Engineering Karpagam Institute of Technology
AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION
AN ULTRA-CHEAP GRID CONNECTED INVERTER FOR SMALL SCALE GRID CONNECTION Pramod Ghimire 1, Dr. Alan R. Wood 2 1 ME Candidate Email: [email protected] 2 Senior Lecturer: Canterbury University
Paralleling Power Sources Which Share a Common Neutral
Paralleling Power Sources Which Share a Common Neutral By: Tony Hoevenaars, P.E., President & CEO, Mirus International, Inc. Mike McGraw, President, NSOEM, Inc. When paralleling power sources that share
Implementation of High Step-Up Solar Power Optimizer for DC Micro Grid Application
Implementation of High tepup olar Power Optimizer for C Micro Grid Application hihming Chen, KeRen Hu, TsorngJuu Liang, and YiHsun Hsieh Advanced Optoelectronic Technology Center epartment of Electrical
Control of a Three Phase Induction Motor using Single Phase Supply
Control of a Three Phase Induction Motor using Single Phase Supply G. R. Sreehitha #1, A. Krishna Teja *2, Kondenti. P. Prasad Rao #3 Department of Electrical & Electronics Engineering, K L University,
Analysis of PV cell fed High Voltage Gain Seven and Nine level inverter with Reduced Switches
Analysis of PV cell fed High Voltage Gain Seven and Nine level inverter with Reduced Switches Ch.Vedasri P.G. Scholar, Department of Electrical & Electronics Engineering, Chirala Engineering College, Chirala;
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT
EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT 4 Understand single-phase alternating current (ac) theory Single phase AC
Modeling Grid Connection for Solar and Wind Energy
1 Modeling Grid Connection for Solar and Wind Energy P. J. van Duijsen, Simulation Research, The Netherlands Frank Chen, Pitotech, Taiwan Abstract Modeling of grid connected converters for solar and wind
Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement
American Journal of Applied Sciences 3 (1): 1649-1654, 2006 ISSN 1546-9239 2006 Science Publications Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement
Development of Micro-Hydro Power Plant using Transistor Clamped Multilevel Inverter
Development of Micro-Hydro Power Plant using Transistor Clamped Multilevel Inverter Prem Kumar Chaurasiya 1, Jaydeep Lakwal 2, Manish Singh Bharti 3 Assistant Professor, Department of Mechanical Engineering,
How To Write A Novel Active Power Filter For 3-Phase 4-Wire Power System
International Journal of Innovative Computing, Information and Control ICIC International c 2013 ISSN 1349-4198 Volume 9, Number 6, June 2013 pp. 2619 2634 A NOVEL ACTIVE FILTER FOR UNBALANCED 3-PHASE
Power Quality Issues, Impacts, and Mitigation for Industrial Customers
Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing
98% Efficient Single-Stage AC/DC Converter Topologies
16 POWER CONVERTERS www.teslaco.com 98% Efficient Single-Stage AC/DC Converter Topologies A new Hybrid Switching Method is introduced in this article which for the first time makes possible AC/DC power
Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions
Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions Padma Chaturvedi 1, Amarish Dubey 2 1 Department of Electrical Engineering, Maharana Pratap Engineering College,
ECONOMIC AND ELECTRICAL BENEFITS OF HARMONIC REDUCTION METHODS IN COMMERCIAL FACILITIES
ECONOMIC AND ELECTRICAL BENEFITS OF HARMONIC REDUCTION METHODS IN COMMERCIAL FACILITIES Jonathan K. Piel Engineering Manager Harmonics Limited [email protected] Daniel J. Carnovale, P.E. Power
Network Theory Question Bank
Network Theory Question Bank Unit-I JNTU SYLLABUS: Three Phase Circuits Three phase circuits: Phase sequence Star and delta connection Relation between line and phase voltages and currents in balanced
Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a
Harmonics and transformers Harmonic component filter Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics
High Frequency Modeling for Cable and Induction Motor Over-voltage Studies in Long Cable Drives
IEEE Industrial Application Society 36th Annual Meeting Page of 8 Chicago, Illinois, USA, September 3 October 5, High Frequency Modeling for Cable and Induction Motor Over-voltage Studies in Long Cable
Design and Development of Speed Control of Induction motor drive using Pulse-Width Modulation
Design and Development of Speed Control of Induction motor drive using Pulse-Width Modulation Jigar Vaidya 1, Vatsal Shukla 2, Darshan Kale 3 1 UG Student, Electrical Department,[email protected], +91-9662532919
The design and performance of Static Var Compensators for particle accelerators
CERN-ACC-2015-0104 [email protected] The design and performance of Static Var Compensators for particle accelerators Karsten Kahle, Francisco R. Blánquez, Charles-Mathieu Genton CERN, Geneva, Switzerland,
Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part I)
00-00-//$0.00 (c) IEEE IEEE Industry Application Society Annual Meeting New Orleans, Louisiana, October -, Modeling and Analysis of DC Link Bus Capacitor and Inductor Heating Effect on AC Drives (Part
Development of High Frequency Link Direct DC to AC Converters for Solid Oxide Fuel Cells (SOFC)
Development of High Frequency Link Direct DC to AC Converters for Solid Oxide Fuel Cells (SOFC) Dr. Prasad Enjeti Power Electronics Laboratory Department of Electrical Engineering College Station, TX -
High Intensify Interleaved Converter for Renewable Energy Resources
High Intensify Interleaved Converter for Renewable Energy Resources K. Muthiah 1, S.Manivel 2, Gowthaman.N 3 1 PG Scholar, Jay Shriram Group of Institutions,Tirupur 2 Assistant Professor, Jay Shriram Group
Performance Analysis of Multi Level Inverter with DC Link Switches for Renewable Energy Resources
International Journal of Innovative Technology and Exploring Engineering (IJITEE) ISSN: 2278-3075, Volume-2, Issue-6, May 2013 Performance Analysis of Multi Level Inverter with DC Link Switches for Renewable
Renewable Energy System for an Isolated Micro Grid
Tiago Rodrigues, J. G. Pinto, Vítor Monteiro, Delfim Pedrosa, João L. Afonso, Renewable Energy System for an Isolated Micro Grid IEEE IECON Industrial Electronics Conference, pp.1636-1642, Dallas Texas
RECENTLY, interest in distributed generation systems
IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL 19, NO 6, NOVEMBER 2004 1551 Control of Distributed Generation Systems Part II: Load Sharing Control Mohammad N Marwali, Member, IEEE, Jin-Woo Jung, Student
ULRASONIC GENERATOR POWER CIRCUITRY. Will it fit on PC board
ULRASONIC GENERATOR POWER CIRCUITRY Will it fit on PC board MAJOR COMPONENTS HIGH POWER FACTOR RECTIFIER RECTIFIES POWER LINE RAIL SUPPLY SETS VOLTAGE AMPLITUDE INVERTER INVERTS RAIL VOLTAGE FILTER FILTERS
ELECTRONIC POWER SYSTEMS
ELECTRONIC POWER SYSTEMS TRADEOFFS BETWEEN SINGLE-PHASE & THREE-PHASE POWER WHITE PAPER: TW0057 1 Executive Summary Modern Electronic Systems are quite often powered from a three-phase power source. While
Simulation on Micro Wind Power Generator with Battery Energy Storage for Critical Load
Simulation on Micro Wind Power Generator with Battery Energy Storage for Critical Load Pankaj Thakur*, Ms. Durga Sharma (Assistant Professor)** *(Department of Electrical and Electronics Engineering, Dr.
Design and Simulation of Soft Switched Converter Fed DC Servo Drive
International Journal of Soft Computing and Engineering (IJSCE) ISSN: 2231-237, Volume-1, Issue-5, November 211 Design and Simulation of Soft Switched Converter Fed DC Servo Drive Bal Mukund Sharma, A.
7-41 POWER FACTOR CORRECTION
POWER FTOR CORRECTION INTRODUCTION Modern electronic equipment can create noise that will cause problems with other equipment on the same supply system. To reduce system disturbances it is therefore essential
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
Three-port DC-DC Converters to Interface Renewable Energy Sources with Bi-directional Load and Energy Storage Ports
Three-port DC-DC Converters to Interface Renewable Energy Sources with Bi-directional Load and Energy Storage Ports A DISSERTATION SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA
New Pulse Width Modulation Technique for Three Phase Induction Motor Drive Umesha K L, Sri Harsha J, Capt. L. Sanjeev Kumar
New Pulse Width Modulation Technique for Three Phase Induction Motor Drive Umesha K L, Sri Harsha J, Capt. L. Sanjeev Kumar Abstract In this paper, various types of speed control methods for the three
DATA CENTER POWER SYSTEM HARMONICS: AN OVERVIEW OF EFFECTS ON DATA CENTER EFFICIENCY AND RELIABILITY
DATA CENTER POWER SYSTEM HARMONICS: AN OVERVIEW OF EFFECTS ON DATA CENTER EFFICIENCY AND RELIABILITY EDITORS: Mietek Glinkowski, ABB Inc. Lynn Simmons, Dell David Loucks, Eaton Dusty Becker, Emerson Network
DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT
DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT by Philip J. A. Ling, P.Eng. Cyril J. Eldridge, B. Sc. POWERSMITHS INTERNATIONAL
Genetic Algorithm approach to find excitation capacitances for 3- phase smseig operating single phase loads
Genetic Algorithm approach to find excitation capacitances for 3- phase smseig operating single phase loads Authors & Affiliation: V.Ravi Kiran, V.Manoj and P.Praveen Kumar Asst. Professor, EEE Dept GMRIT,
An Isolated Multiport DC-DC Converter for Different Renewable Energy Sources
An Isolated Multiport DC-DC Converter for Different Renewable Energy Sources K.Pradeepkumar 1, J.Sudesh Johny 2 PG Student [Power Electronics & Drives], Dept. of EEE, Sri Ramakrishna Engineering College,
HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS
White Paper: MIRUS-TP003-A January 15, 2014 HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc.
Design of Solar Power Optimizer And Eliminating Leakage Current In Multi-Level Inverter For PV Systems
Design of Solar Power Optimizer And Eliminating Leakage Current In Multi-Level Inverter For PV Systems A. Asaph 1, Dr. P. Selvan 2 1 PG Scholar, 2 Head of the Department, Erode Sengunthar Engineering College,
A Review of Non-Isolated High Step-Up DC/DC Converters in Renewable Energy Applications
A Review of Non-Isolated High Step-Up DC/DC Converters in Renewable Energy Applications Wuhua Li, Xiaodong Lv, Yan Deng, Jun Liu, Xiangning He College of Electrical Engineering, Zhejiang University Hangzhou,