Commercial Service Cabinets. Review of available information on energy consumption



Similar documents
Energy Efficiency. Bars & RestauRants.

Energy Efficiency HOSPITALITY.

HEATING, VENTILATION & AIR CONDITIONING

Jeremy Tait Tait Consulting Limited With technical support from Judith Evans RD&T, UK

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

PARTNERING. in Energy. Solutions A PROGRAM TO PROMOTE BUSINESS ENERGY EFFICIENCY

PARTNERING. in Energy. Solutions A PROGRAM TO PROMOTE BUSINESS ENERGY EFFICIENCY

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

Guide to Good Commercial Refrigeration Practice. Part 2. System Design and Component Selection

Pacific Gas and Electric Company Energy-Efficiency Rebates for Your Business. Refrigeration Rebate Catalog Saving energy for a brighter future

Professional Kitchens

Energy savings from voltage optimisers

Small Business Energy Efficiency and Specialty Equipment

Energy efficient products - helping us cut energy use

Switching Energy Providers and PECO Smart Ideas. March 23, 2011

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Drives and motors. A guide to using variable-speed drives and motors in retail environments

FROST PREDICTION ON EVAPORATOR COILS OF SUPERMARKET DISPLAY CABINETS USING ARTIFICIAL NEURAL NETWORKS

Glass Door Bar Fridge Buyers Guide

Undercounter & Slimline Cabinet Range HR/LR 120 HRB/LRB120 HR/LR 140 HR/LR 150 HR/LR 200 HR/LR 240 HR/LR 360 HR/LR 410

Coldrooms designed for your application

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Frequently Asked Questions. Isotherm Fridge & Freezers

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Saving energy in your business

164,491 SF Food Production Facility Situated on 10 Acres Available in

Electricity Use in the Commercial Kitchen

How To Understand Evaporator

Energy Saving case Study On a 22KW Centrifugal Fan Application

Energy Efficiency Testing for HVAC/R Helping you comply with energy efficiency regulatory programs

How To Design A Refrigeration System

State of the Art Energy Efficient Data Centre Air Conditioning

UNDER/OVER COUNTER CHILLERS AND FREEZERS GN 1/1 IN STAINLESS STEEL AISI 304 «SCOTCH BRITE» AND WHITE SKINPLATE WITH SOLID OR GLASS DOOR

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Analysis of data centre cooling energy efficiency

DEFROSTING. Service Engineers Section Technical Bulletin No 3

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

Low Profile Unit Cooler

Meaco 30L and Meaco 40L dehumidifier instruction manual

Direct Fresh Air Free Cooling of Data Centres

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

Chapter 3.4: HVAC & Refrigeration System

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Intertek Testing Services 70 Codman Hill Road Boxborough, MA WORLD LAB

Troubleshooting Your Refrigerator

ArcticStore. product guide environmentally friendly storage solutions

BGE Smart Energy Savers Program Energy Efficiency and Demand Response Programs December 4, 2012 USEA Global Workshop On Clean Energy Development

Percent per Degree Rule of Thumb for Refrigeration Cycle Improvement

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

APPLICATIONS AND DEFINITIONS

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Daikin Altherma. hybrid heat pump. The natural combination

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

Information Guide. The Application of Heat Pump Boilers. Issue Eighteen >

How To Save Money On Energy

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

Inverter technology. bulletin

SOLAR COOLING WITH ICE STORAGE

Specific Heat (slope and steepness)

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Optimization of Water - Cooled Chiller Cooling Tower Combinations

SWIMMING POOL HEAT PUMP Owners Manual

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS

CLIMATE CHANGE POLICY FRAMEWORK FOR REFRIGERATION AND AIR CONDITIONING SECTOR

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'

Energy efficient room air conditioners best available technology (BAT)

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Your energy costs. A room-by-room guide. P.O. Box San Diego, CA Connect at sdge.com

Data Center Environments

Refrigeration Books NEW 2003

Overview. PG&E and Energy Efficiency. CA Energy Efficiency Regulatory & Policy Roadmap. Financing Options for Efficiency & Demand Response

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Energy saving tips for home

Environmental Data Center Management and Monitoring

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Split units TH with hermetic compressors

Freezers - Ultrafreezers. Platilab & Irilab Series

Daikin Altherma hybrid heat pump. The natural combination

Commercial Energy Efficiency Program. Save money, reduce energy use and earn incentives. Save money, reduce energy use and qualify for incentives

SMM. Installation Operation Maintenance

ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Home Energy Evaluation Report

Transcription:

Commercial Service Cabinets Review of available information on energy consumption November 2007 By Judith A Evans Produced by: Food Refrigeration and Process Engineering Research Centre (FRPERC), University of Bristol, Churchill Building, Langford, North Somerset, BS40 5DU, UK Tel: ++44 (0)117 928 9239 Fax: ++44 (0)117 928 9314 e-mail: frperc-bris@bristol.ac.uk Web: http://www.frperc.bris.ac.uk Job: 2006013 catr-commservcabs.doc 1 of 12

Contents Market... 3 Performance in test rooms...4 Performance in use...5 Door openings...7 Test performance versus real life performance...8 Effect of location...8 Energy saving features...9 Future potential... 10 References... 11 Job: 2006013 catr-commservcabs.doc 2 of 12

Market Refrigerated Commercial Service Cabinets (CSCs) are used to store food and/or drink in commercial catering facilities. There are approximately 500,000 units in use in the UK. The vast majority of the cabinets sold are integral cabinets (with refrigeration system within the case) but remote units (where the refrigeration system is separate from the cabinet) are also available. Remote cabinets make up less than 5% of the current market and there is no indications that this is likely to increase in the near future. Refrigerated CSCs are in use in virtually all-commercial catering facilities. The majority of the market is for chilled or frozen upright cabinets with one or two doors (between 400 and 600 litres for single door cabinets and 1,300 litres for double door cabinets) or under counter units with up to four doors (150 to 800 litres). There is however a sector of the market (approximately 25% of the total number of units) that is bespoke units for particular applications and this can account for between zero and 70% of the market for individual cabinet manufacturers CSCs use 12% of commercial refrigeration energy (Figure 1) (1). The average energy consumption for chilled cabinets is 2,920 kwh per year and for frozen is 5,475 kwh per year. This equates to 7 PJ (2.2 TWh) per year [Error! Bookmark not defined.]. MTP reference and policy scenario figures indicate that the energy used by CSCs will increase to 2020 but if EBP (Energy best Practice) is used the energy consumption will decrease by approximately 30% by 2020 (Figure 2). Walk in cold rooms 14% Process chillers Integral retail display cabinets 24% 12% Remote retail display cabinets 24% Commercial service cabinets 12% Cellar cooling equipment 7% Refrigerated vending Ice making 1% machines 6% Job: 2006013 catr-commservcabs.doc 3 of 12

Figure 1. Energy used in commercial refrigeration in the UK. Reference scenario Policy scenario EBP scenario 2500 2000 GWh/year 1500 1000 500 0 1999 2002 2005 2008 2011 2014 2017 2020 Figure 2. MTP predictions of energy consumed by CSCs to 2020. The UK market for CSCs is worth 90-95 m per year and is dominated by 3 companies (Fosters, Williams and Gram). These 3 companies have approximately 75% of the UK market. Other companies such as Electrolux, Metos spa, Porkka, Caravell and imports from China and the Far East constitute the remainder of the UK market. Approximately 58,000 units are sold per year, of which 9,000 are under counter units. Prices per unit range from 900 to 1,800 (depending on size of cabinet) with a typical price of 1,000. The overall market is increasing slowly by a few percent per year. Performance in test rooms CSCs are generally tested in test rooms to assess performance in terms of energy and temperature control. No directly applicable test standards exist for testing CSCs and therefore a retail display test standard, EN441, is commonly used. EN441 is now superseded by EN23953 but for assessment for schemes such as the ECA (Enhanced Capital Allowance) EN441 remains the test standard. Generally for such tests the energy consumption is related to the net storage volume of food as an Energy Efficiency Index (EEI). Tests include door openings to replicate usage. The performance reported in test room conditions (30 C and 55% RH) varies considerably. Data from FRPERC tests, the ECA scheme and the Danish Positive List is presented in Figure 3 (all from tests using EN441). It can be seen that the performance of the cabinets Job: 2006013 catr-commservcabs.doc 4 of 12

varies considerably in terms of functionality (amount of energy consumed to store a volume of food). 90 80 70 Frozen uprights Chilled uprights Chilled under counters 60 EEI (kwh/48h/m 3 ) 50 40 30 20 10 0 0 250 500 750 1000 1250 1500 Gross vol (litres) Figure 3. Energy consumed by cabinets in test conditions. If the functionality of CSCs is compared with retail cabinets using data from the ECA scheme and from data presented in Evans, Scarcelli and Swain, 2007 (2) the functionality of chilled CSCs (solid door chilled cabinets) compares favourably with those with glass doors (Table 1). However, the performance of frozen CSCs (solid door frozen cabinets) compared quite poorly with glass door cabinets. This indicates that there is potential to improve these cabinets. EEI (kwh/48h/m 3 ) Mean Max Min Solid door (chilled) 15.24 68.74 4.85 Chest freezer 16.26 36.53 4.47 Glass door (chilled) 22.40 41.65 10.07 Multi-deck (chilled) 24.31 68.92 7.85 Glass door (frozen) 38.34 54.58 11.88 Solid door (frozen) 39.28 82.04 24.75 Well (frozen) 43.15 89.19 16.72 Table 1. EEI of chilled and frozen CSCs and various retail display cabinets. Performance in use There is little published data on energy consumption of CSCs in use. Available data is shown in Figure 4. Although each cabinet type is of similar size and therefore can be directly compared in terms of functionality there is a large difference in energy consumed by each Job: 2006013 catr-commservcabs.doc 5 of 12

CSC type. This is likely to be due to different inherent efficiencies and also to usage and location of the cabinet. Single door upright freezer5 Double door chiller 4 Double door counter chiller 3 Single upright chiller 2 Casino Single door counter chiler 1 Department store Hotel Pub 0 0 5 10 15 20 Energy (kwh/24hr) Figure 4. Energy consumed by different types of CSCs in varied locations. Figure 4 demonstrates that considerable savings in energy are achievable using current technology. If the best and worst cabinets are superimposed on the MTP data from Figure 2 the potential annual savings are approximately 1,000 GWh per year (Figure 5). This equates to an average saving on current EBP of 63%. This demonstrates that considerable savings are achievable using current technology and although improvements in current technology are possible, that one of the major issues is persuading end users to purchase the most efficient cabinets. Pedersen (3), published a study in 2004 showing improvements to Gram cabinets of 47% (freezers) and 74% (chillers) in usage (from 6.26 kwh/day to 1.62 kwh/day for the chillers and from 8.53 kwh/day to 4.54 kwh/day for the freezers). The original cabinets energy was divided as shown in Figure 6. By changing the refrigerant, using energy efficient components and optimising heaters, door seals and the control system energy savings were achieved. The greatest savings were achieved by optimising the door seals, using DC fans and by using compressor discharge gas for evaporator water evaporation. Job: 2006013 catr-commservcabs.doc 6 of 12

2500 Reference scenario Policy scenario EBP scenario Best cabinets Worst cabinets 2000 GWh/year 1500 1000 500 0 1999 2002 2005 2008 2011 2014 2017 2020 Figure 5. Best and worst cabinets in use superimposed on MTP data (assumes best cabinet improve 2% year on year). Figure 6. Energy consumption by components in Gram cabinet prior to modifications (from Pedersen, 2004). Door openings The cabinets developed by Pedersen were tested in usage and data on real life usage was collected. The number of door openings varied considerably depending on cabinet usage but was up to 24 door openings per day for a freezer and up to 280 door openings per day for a chiller. This compares to test standard (EN441) door openings of 73 door openings per door Job: 2006013 catr-commservcabs.doc 7 of 12

per 12 hour door opening period 1 (total open time of 0.29 hour per door). This would indicate that the test standard has a tendency to encourage over specification of freezers and under specification of chillers. The number of door openings should be related to energy consumed and this was shown to be broadly true by Pedersen. The time that the cabinet door is open should also influence energy consumption. If cabinets tested to EN441 (12 second door openings every 10 minutes) and EN23953 (6 second door openings every 10 minutes) are compared the energy consumed by cabinets in the EN23953 tests is approximately 37% lower than that in the EN441 test. Test performance versus real life performance There is very little data available to compare energy consumed in tests situations with that in real life usage. The limited data available shows that the most efficient cabinet in a test situation may not necessarily be the most efficient cabinet in use. However, the way the cabinets were used may not be directly comparable and therefore more work is required to quantify differences. Effect of location 12 10 Energy (kwh/24hr) 8 6 4 2 0 Cabinet 1 -------------------------- Cabinet 2 ------------------------------------------------------- ---- Figure 7. Energy consumed by 2 cabinets in varied locations (cabinet 1 is a single door chiller and cabinet 2 is an under counter chiller/freezer). 1 N.b. Door openings occur for 12 hours in every 24 hour period of the test. Job: 2006013 catr-commservcabs.doc 8 of 12

There is little data on effect of location of cabinet on CSC energy performance. Limited data is shown in Figure 7 that demonstrates that depending on location (and usage) a cabinet can consume vastly varied amounts of energy. The effect of different locations on energy consumed by a range of cabinets is shown in Figure 8. The data presented is from cabinets of the same size but different model and therefore the inherent efficiency and location of the cabinet will also have an influence on energy consumed. The energy consumed varies considerably demonstrating that location and cabinet model have a large effect on energy consumption. Interestingly the energy consumed by all cabinets is considerably lower than the average in Table 1 indicating that test room conditions provide a harsher environment than in real life usage. This may indicate that chiller cabinets as well as freezers (see comment on freezer specification in Door openings section above) are over specified to pass a test standard and that this may lead to inefficiencies in usage. It should be noted that although energy was recorded in the cabinets while in use the temperature within the cabinet was not monitored and therefore any energy savings achieved may have been at the expense of higher product temperatures. Pub Pub Casino Department Store restaurant Department Store restaurant Single door upright chiller cabinet 0 2 4 6 8 10 Energy (kwh/24hr ) Figure 8. Effect of location on energy consumed by a single cabinet type (single door chiller). Energy saving features Table 2 shows energy saving features either commonly incorporated into CSCs or which could be utilised to reduce energy. Job: 2006013 catr-commservcabs.doc 9 of 12

Technology Rationale Commonly used in CSCs Estimated energy saving potential Suction-liquid heat exchange Sub cool liquid Yes 10% Liquid line solenoid Removed off-cycle losses Not standard 10% (dependent on off cycle time) Control systems - fan pulsing, compressor start up control Inverter driven compressors Reduce unnecessary loads Not standard Up to 30% Reduction in start up losses, off cycle losses No 20% Off-cycle defrost For chilled cabinets only Yes 5% Discharge gas defrost water evaporations Removed need for electrical heaters DC fans Lower energy usage Not standard, becoming more widely used Gasket heaters Removing/reducing gasket heaters. Lower energy usage Yes 2% 1% Not standard 1% Improved insulation Reduced heat load No 20% n.b. savings are not necessarily cumulative. Table 2. Energy saving features in CSCs. Future potential The fundamental design of CSCs has changed little over the past 20 years. Step changes have occurred that have improved efficiency. There is still an emphasis on first cost of units rather than life cycle costing and manufacturers have difficulty justifying the higher costs of energy saving components against imported cabinets that have a low initial cost but higher energy consumption in use. Potential exists to improve frozen CSCs as these compare unfavourably with other options. In a commercial kitchen frozen cabinets are usually only opened at the beginning and end of a day and therefore chest freezer should be a more efficient option that would not have a great influence on usability of the cabinet. Schemes such as the ECA have reduced compliance thresholds and are therefore encouraging manufacturers to implement DC fans and other energy saving features. There is still a large variation between the most, and least, efficient cabinets and there is considerable potential to save energy using currently available technologies. There is considerable lack of data on performance of cabinets in use. Improved understanding of requirements in commercial kitchens would enable cabinets to be designed and optimised for usage. Job: 2006013 catr-commservcabs.doc 10 of 12

References 1) Sustainable products 2006: Policy analysis and projections. MTP. 2) Evans, J.A., Scarcelli, S., Swain, M.V.L., 2007. Temperature and energy performance of refrigerated retail display and commercial catering cabinets under test conditions. International Journal of Refrigeration 30, 398-408. 3) Pedersen, P.H., Soe, L. and Jensen, F. New Generation of Professional Kitchen Appliances with Natural Refrigerants and Reduced Energy Consumption. 6th Gustav Lorentzen Natural Working Fluids Conference, Glasgow, UK Job: 2006013 catr-commservcabs.doc 11 of 12

Insurance requirements The work associated with this contract / grant has been carried out in accordance with the highest academic standards and reasonable endeavours have been made to achieve the degree of reliability and accuracy appropriate to work of this kind. However, the University does not have control over the use to which the results of this work may be put by the Company and the Company will therefore be deemed to have satisfied itself in every respect as to the suitability and fitness of the work for any particular purpose or application. In no circumstances will the University, its servants or agents accept liability however caused arising from any error or inaccuracy in any operation, advice or report arising from this work, nor from any resulting damage, loss, expenses or claim. 2007, FRPERC, University of Bristol Job: 2006013 catr-commservcabs.doc 12 of 12