CITIZENS PROPERTY INSURANCE CORPORATION BUILDING TYPE II AND III MITIGATION VERIFICATION AFFIDAVIT



Similar documents
CITIZENS PROPERTY INSURANCE CORPORATION. STREET ADDRESS: Gulf Blvd, Maderia Beach, FL Six story masonry residence

providing documentation that validates the year of construction. Acceptable documents include

Wind Mitigation Inspection

Protecting YOUR NEW HOME FROM Wind Damage

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

ELIGIBILITY CHECKLIST:

Wind Mitigation Discount Plan

Bay County Builders Services Main Office FAX: (850) PHONE: (850)

South Carolina Department of Insurance

Insurance Mitigation Factors for Homeowners Purchasing Garage Doors In Florida

The Florida Building Code

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

ROOFING CONTRACTORS QUESTIONNAIRE

ROOFING CONTRACTOR SUPPLEMENTAL APPLICATION

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOF PERMITTING A REFRESHER WORKSHOP September 11, 2014

Who Can Apply (A or B)

Metal Roof Systems in High-Wind Regions

Genesis Home Inspections LLC

CITIZENS PROPERTY INSURANCE CORPERATION

CODE IN EFFECT: 2010 FLORIDA BUILDING CODE PERMIT APPLICATIONS MUST BE FILLED OUT COMPLETELY

Hurricane Damage. How Wind Forces Affect Homes

NRCA s steep-slope manual is thoroughly revised for 2013

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

The Florida Building Code

SECTION 3 ONM & J STRUCTURAL ANALYSIS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

ROOFING CONTRACTOR SUPPLEMENTAL APPLICATION

Property Managers Professional Package Product

CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings

FLORIDA PRODUCT APPROVAL

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

Four Point Inspection


HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

CITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL ROOFING PERMIT APPLICATION

Specified Professions Professional Liability Product

Mark Cramer Inspection Services, Inc.

Informational Bulletin

Materials and Colors

CHAPTER 7: Building Systems ROOFING SYSTEMS

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

During storm events, a roof is expected to perform many functions from preventing water intrusion

Specified Professions Professional Liability Product

Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course. Section 1: Introduction

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

Dollars & Sense of Compliance!

What to Do About Your Roof and How to Hire a Roofing Contractor

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Protecting Your Home from Wind Damage

Please read the entire document before purchasing and installing any of these products

Specified Professions Professional Liability Product

Protecting Your Home From Hurricane Wind Damage

Miami Beach Building Department

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

Contractor s Statement of Responsibility for Seismic-Force-Resisting Systems This form is to be filled out by the contractor.

ATLAS Roofing Products

How To Compare Roofing Material

Detached accessory structures that contain no conditioned floor area are exempt.

ROOF ASSEMBLIES CHAPTER 9

2008 Florida Residential Wind Loss Mitigation Study

FORTIFIED Home. The key to resilient communities

FARMERS MUTUAL INSURANCE COMPANY UNDERWRITING GUIDELINES HOMEOWNER PROGRAM

Residential Roofing Guide

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC.

Colorado State University. Durrell Center Roof Repair

High Wind & Hail Standards

Property Policyholder Risk Improvement Report and Hurricane Survey

HOMEOWNERS UNDERWRITING GUIDE

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

COMMERCIAL BUILDING APPLICATIONS

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Asphalt Shingle Application Requirements

Breakaway Walls

CONSTRUCTION LAW. Mechanical Roofing Contractor. Electrical Class A Air Conditioning. Contractor Class B Air Conditioning

tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE

metal Duil~ing manufacturers Association

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Roofing Supplemental Application

Who Can Apply (A or B)

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Metal Roofing Practical Design

AIA PRESENTATION. Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour

Florida Building Code, 5th Edition (2014) June 30 th, 2015

Transcription:

CITIZENS PROPERTY INSURANCE CORPORATION BUILING TYPE II AN III MITIGATION VERIFICATION AFFIAVIT This affidavit must be completed to capture mitigation features applicable to a Type II (4 to 6 story) or Type III (7 or more story) building. This affidavit is required for either residential condominium unit owners or commercial residential applicants requesting mitigation credits in such buildings. PREMISES#: SUBJECT OF INSURANCE:Bouchelle BUILING#: 432 STREET ARESS: 432 Bouchelle r New Sm rna Beach Fl 32169 # STORIES: 4 BLG ESCRIPTION: Condominiums BUILING TYPE: [2(111 (4 to 6 stories) III (7 or more stories) Terrain Exposure Category must be provided for each insured location. I hereby certify that the building or unit at the address indicated above TERRAIN EXPOSURE CATEGORY as defined under the Florida Building Code is (Checx One): Exposure C or IZI Exposure B Certification below for purposes of TERRAIN EXPOSURE CATEGORY above does not require personal inspection of the premises. Certification of Wind Speed is required to establish the basic wind speed of the location (Complete for Terrain B only if Year Built On or After Jan.1. 2002). I hereby certify that the basic WIN SPEE of the building or unit at the address indicated above based upon county wind speed lines defined under the Florida Building Code (FBC) is (Check One): ~100 or ~110 or rn ~120 Certification of Wind esign is required when the buildings is constructed in a manner to exceed the basic wind speed design established for the structure location (Complete for Terrain B only if Year Built On or After Jan.t, 2002). I hereby certify that the building or unit at the address indicated above is designed and mitigated to the Florida Building Code (FBC) WIN ESIGN of (Check One): ~100 or ~110 or IX! ~120 Certification for the purpose of establishing the basic WIN SPEE or WIN SPEE ESIGN above does not require personal inspection of the premises. Specify the type of mitigation device(s) installed: Roof verings Reinforced Concrete Roof - Type II or '" A roof structure composed of cast-in-place or pre-cast structural concrete designed to be self-supporting integrally attached to wall/support system. and Level A (Non FBC Equivalent) - Type II or '" All roof cover types and configurations that do not meet Level B below. Level B (FBC Equivalent) - Type II or '" Roof coverings that satisfy all of the following conditions and are one of the following types: 1. Built-Up 2. Modified Bitumen 3. Sprayed Polyurethane foam 4. Liquid membrane applied over concrete 5. Asphalt roll roofing 6. Wood shakes in good condition. attached with at least two mechanical fasteners 7. Ballasted roof designed to meet the design wind speed requirements 8. Asphalt roof coverings installed in accordance ASTM 0 3161 (modified for 110 mph) or Miami ade County PA 107-95. All mechanicalequipmentmust be adequatelytied to the roofdeck to resistoverturningand slidingduringhighwinds.anyflat roofcoveringwithflashingor copingmust be mechanicallyattachedto the structurewithface fasteners(no clip/cleatsystems); and roof coveringson flat roofsmust be 10 yearsold or less. MIT-BT II & ill (5/2008)

o CITIZENS PROPERTY INSURANCE CORPORATION BUILING TYPE II AN III MITIGATION VERIFICATION AFFIAVIT Roof eck Attachment Level A - Wood or Other eck Type II only Roof deck composed of sheets of structural panels (plywood or OS8). Or Architectural (non-structural) metal panels that require a solid decking to support weight and loads. Or Other roof decks that do not meet Levels B or C below. Level B - Metal eck Type II or III ~Of qi'level deck made of structural panels that span from joist to joist. C - Reinforced Concrete Roof eck Type, II or III A roof structure composed of cast-in-place or pre-cast structural concrete designed to be self-supporting and integrally attached to wall/support system. seco~ Water Resistance q!/underlayment A self-adhering polymer modified bitumen roofing undertayment (thin rubber sheets with peel and stick underside located beneath the roof covering and normal felt underlayment) with a minimum width of 6" meeting the requirements of ASTM 0 1970 installed over all plywood/os8 joints to protect from water intrusion. All secondary water resistance products must be installed per the manufacturer's recommendations. Roofing felt or similar paper based products are not acceptable for secondary water resistance. Foamed Adhesive A foamed polyurethane intrusion. sheathing adhesive applied over all joints in the roof sheathing to protect interior from water Opening Protection Class A (Hurricane Impact) - All glazed openings (windows, Skylights, sliding glass doors, doors with windows, etc) less than 60 feet above grade must be protected with impact resistant coverings (e.g. Shutters), impact resistant doors, and/or impact resistant glazing that meet the requirements of: SST12; ASTM E 1886 and ASTM E 1996 (Missile Level C - 9 Ib); Miami-ade PA 201,202, and 203; or Florida Building Code TAS 201,202 and 203. All glazed openings between 30 and 60 feet above grade must meet the Small Missile Test of the respective standard. All glazed openings less than 30 feet above grade shall meet the Large Missile Test of the respective standard. Class B (Basic Impact) - All glazed openings (windows, skylights, sliding glass doors, doors with windows, etc) must be protected with impact resistant coverings (e.g. shutters), impact resistant doors, and/or impact resistant glazing that meet the requirements of: ASTM E 1886 and ASTM E 1996 (Missile Level B - 4.5Ib) All glazed openings between 30 and 60 feet above grade must meet the Small Missile Test of the respective standard. All glazed openings less than 30 feet above grade shall meet the Large Missile Test of the respective standard. MIT-BT II & III (5/2008) 2

CITIZENS PROPERTY INSURANCE CORPORATION BUILING TYPE II AN III MITIGATION VERIFICATION AFFIAVIT I certify that I am (CHECK ONE OF THE FOLLOWING): CERTIFICA nos rn a resident licensed General, or Building Contractor, 0 a Licensed Building Inspector, 0 a Registered Architect, 0 an Engineer in the State of Florida, 0 a Building Code Official (who is duly authorized by the State of Florida or its county's municipalities to verify building code compliance). I also certify that I personally inspected the premises at the Location Address listed above on the date of this Affidavit. In my professional opinion, based on my knowledge, information and belief, I certify that the above statements are true and correct. This Affidavit and the information set forth in it are provided solely for the purpose of verifying that certain structural or physical characteristics exist at the Location Address listed above and for the purpose of permitting the Named Insured to receive a property insurance premium discount on insurance provided by Citizens Property Insurance Corporation and for no other purpose. The undersigned does not make a health or safety certification or warranty, express or implied, of any kind, and nothing in this Affidavit shall be construed to impose on the undersigned or on any entity to which the undersigned is affiliated any liability or obligation of any nature to the named insured or to any other person or entity. & Mitigation ServiceS'hone: 386-804-6832 Name of Inspector ate: License ficbc 059706 8/20/2013 Signature: Applicant's Signature: ate: "Any person who knowingly and with intent to injure, defraud, or deceive any insurer files a statement of claim or an application containing any false, incomplete, or misleading information is guilty of a felony of the third degree." MIT-BT II & III (5/2008) 3