OROT RABIN POWER STATION UNITS 1-4. 4 x 350 MW



Similar documents
Natural Gas Conversions of Existing Coal-Fired Boilers

Committed to make a better world

Blast Furnace Gas-Fired Boiler for Eregli Iron & Steel Works (Erdemir), Turkey

RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE

Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control

Combined Cycle Control Overview

Guidelines for Preparing for a Temporary Steam Plant

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Steam Generation Solutions

Recovery Boiler Combustion control system(ccs) & Emergency shutdown(esd).

Boiler Preparation, Start-Up and Shutdown

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Gomaa Mostafa Mohamed El-Gazzar Mechanical Commissioning Manager PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

University of Iowa Power Plant

Presentation Outline. Background

Factory owners must ensure the boiler is:

Water-Tube Package Boilers Reliable and Economical Steam Production

NAWTEC CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY

Operational Flexibility Enhancements of Combined Cycle Power Plants. Dr. Norbert Henkel, Erich Schmid and Edwin Gobrecht

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Energy Saving Solutions. Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

Proven Utility Solutions from John Zink Hamworthy Combustion.

How To Clean Up A Reactor Water Cleanup

GLOBACON 05 HVAC Systems for Cogen

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC October 15, 2008 BOILER PLANT OPERATIONS

Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

2nd IEA Oxyfuel Combustion Conference

Burner Performance Monitoring Using Advanced Analysis of Optical Signals

Energy Efficiency in Steam Systems

EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

Action Plan Template HVAC Page 1

NEW JERSEY CENTER OF EXCELLENCE

HEAVY DUTY STORAGE GAS

SULFURIC ACID MIST PERFORMANCE TEST PROTOCOL. Duke Energy Florida, Inc. Crystal River Power Plant Units 4&5 Crystal River, Citrus County, Florida

I. STEAM GENERATION, BOILER TYPES

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

SRS: THE STANDARDIZED REPOWERING SOLUTION FOR 300MW STEAM POWER PLANTS IN RUSSIA. Matthias Fränkle Siemens Power Generation (PG), Germany

A Case Study on Coal to Natural Gas Fuel Switch

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Control of Boiler Operation using PLC SCADA

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Columbia University Master Planning & Optimization

SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS

Efficiency on a large scale CFB Steam Boilers

Babcock & Wilcox Company Supercritical (Once Through) Boiler Technology

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Boiler NOx Emissions and Energy Efficiency

Condensing Boiler Efficiency

A CASE STUDY: PERFORMANCE AND ACCEPTANCE TEST OF A POWER AND DESALINATION PLANT. Keywords : Power Plant, Boiler Capacity, Electrical Power

Fortum bygger Sveriges största biokraftvärmeverk i Stockholms stad. Daniel Nilsson Värme & Kraftkonferensen, Stockholm 12 november 2014

For installation guide see reverse of book

Delivering quality power plant products, programs and services

Backup Fuel Oil System Decommissioning & Restoration Plan

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Recover Heat from Boiler Blowdown Water

MC (Multi-Circulation) f o r S A G D a n d I n d u s t r i a l A p p l i c a t i o n s

HC900 for Boiler Control Applications

Review of Potential Efficiency Improvements at Coal-Fired Power Plants

The Power Industry Specialists

Job Grading Appeal Decision Under Section 5346 of Title 5, United States Code

Online Infrared Flue Gas Analyzer Gasboard 3000

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Commercial Gas Furnace Upflow

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

Assessing the Changes Required by the Industrial Boiler MACT Regulations

System Assessment Capabilities for Fossil Fuel Power Stations

Building Energy Systems. - HVAC: Heating, Distribution -

Plant Optimization & Performance Software

BOILER OPERATORS HANDBOOK

Pressurized Water Reactor B&W Technology Crosstraining Course Manual. Chapter 9.0. Integrated Control System

912 MW Supercritical Boiler for the next Coal Fired Plant Generation

Evaluate, Clean, and Tune Guidance

Skoda Supercritical Steam Turbine 660 MW

New-generation Integrated Monitoring and Control System

OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

Routine and Emergency Boiler Operation

By K.K.Parthiban / Boiler specialist / Venus Energy Audit System

OPERATIONS & MAINTENANCE SUBCOMMITTEE RECOVERY BOILER SAFETY AUDIT GUIDELINES

RECON WATER HEATER INSTALLATION FORM

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS

SIOUX HYBRID WATER HEATER

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Optimization of Emissions Reduction Equipment (SCR) Jeff Williams SmartProcess Business Development Manager

Transcription:

ISRAEL ELECTRIC OROT RABIN POWER STATION UNITS 1-4 4 x 350 MW COAL BOILER CONVERSION TO LOW NO X NATURAL GAS AND COAL FIRING BY PRIMARY AND SECONDARY MEASURES INSTALLATION Replacing the Burner Management System (BMS) Upgrading / Retrofitting / Replacing the Combustion Control REQUEST FOR INFORMATION (RFI) 04-8185787 חברת החשמל לישראל בע"מ, ת"ד 10 חיפה, 31000 פקס +972-4- 8183146 Fax +972-4-8185787 Israel Electric Corporation Ltd. 10 Haifa 31000 Israel

TABLE OF CONTENTS 1. General Introduction 2. Main Equipment Description 2.1 Steam Generator (Boiler) Description 2.2 The Fuel System 2.3 The Burners 2.4 Air and Flue Gas Flow 2.5 Spray Attemperators 2.6 Condensate & Feedwater Systems 3. Description of the Existing Control and Data Acquisition Systems 3.1 Burner Management System 3.2 The Combustion Control System 3.3 Data Processing and Monitoring System (DPMS) 4. Alternatives for Control Systems 5. Factors Determining the Selected Alternative 6. Requested Information 7. Supplier information 2

1. General Introduction The Israel Electric Corporation (IEC) intends to carry out a retrofit at the Orot Rabin Power Station units 1-4 which consists of four (4) coal fired 350 MW units. These units were commissioned at 1981-1984. The purpose of the retrofit is to achieve low NOx emissions in order to comply with the environmental regulations. The retrofit design is to burn Natural Gas (NG) as a primary fuel and coal as a secondary fuel and will include primary measures (PM) for NG firing and coal firing. The retrofit equipment will be designed for 15 years of and will include SCR installation for NG operation mode and auxiliary equipment. The retrofit for all four (4) units is planned to be finalized until the end of 2016 Israel Electric (IEC) has published a Request For Information (RFI) on 07/08/2011 for 'The Coal Boiler Conversion to Low NOx Natural Gas and Coal Firing by Primary and Secondary Measures Installation'. IEC is investigating the possible solutions for the control systems to accommodate this conversion. The main purpose of this RFI is to understand the feasibility of the different control systems' solutions 3

2. Main Equipment Description, Relevant to the Control Systems 2.1 Steam Generator (Boiler) Description The Orot-Rabin Units 1-4 consist of four drum type steam generators, manufactured by Babcock & Wilcox Canada Ltd. Each unit burns pulverized coal and heavy oil. The maximum continuous capacity of each unit is 2,441,000 lb (1,107,238 kg) of steam per hour at 2050 psig (144 kg/cm 2 gage) and 1005ºF (540ºC). The units are designed to produce the maximum continuous capacity either by burning pulverized coal or heavy oil. Based on originally design, the superheater and reheater steam temperatures are controlled at 1005ºF (540 C) by spray attemperation. At the present, due to operation problems, the Superheater and Reheater steam temperatures are controlled at 977ºF (525 C) and the flue gas recirculation control is disabled (should be replaced by a new system). 2.2 The Fuel System The fuel system includes eight (8) coal feeders, eight (8) coal pulverizers and twenty four (24) burners. The type of the feeder is gravimetric and its manufacture was Stock Equipment Co. The pulverizers were manufactured by B&W Canada Ltd., each with a capacity of 18 tons. The sealing air for the coal feeders and pulverizers is supplied by two (2) seal air fans which were manufactured by Sheldons Manufacturing. The primary air dries and carries the pulverized coal from the pulverizers through the coal pipes to the burners and furnace. There are three (3) coal pipes per pulverizer, each pipe is connected to a burner at the same elevation at the front or the rear wall. 4

2.3 The Burners Each unit consist of twenty four circular burners arranged at four elevations, six at each elevation, three on the front and three on the rear walls. The burners arranged in two common windboxes: one for the three lower elevations and one for the most upper elevation. Ignition is initiated by high capacity gas igniter. Each burner is equipped to fire heavy oil by means of B&W steam atomizers racer type sprayer plate. Total twenty-four (24) oil burners are sized to produce full load steam flow. The burners cannot fire simultaneously heavy oil and coal. It is possible to control the fuel type firing (heavy oil or coal) for each group of burners. The lower elevation of burners is also equipped to fire light oil with air atomization for boiler pressure raising and low load carrying up to 20% of MCR. 2.4 Air and Flue Gas Flow The primary air system consists of two primary air fans (each providing fifty percent required capacities), one steam coil air preheater, one Ljungstrom regenerative air heater. The heated primary air is ducted to pulverizer windboxes. A fraction of air which bypasses the air heater is used to temper, or control the primary air temperature to each pulverizer. The secondary air, which comprises approximately 80% of the total combustion air when firing coal, is supplied by two axial flow forced draft fans. There are three Ljungstrom air heaters, two precipitators, two I.D. fans. 2.5 Spray Attemperators There are two spray type attemperators on this unit. Each attemperator handles steam from one-half of the boiler width. This arrangement has been incorporated to minimize the effect of unbalanced firing and to insure a uniform final steam temperature across the secondary superheater outlet header. RH outlet steam temperature is controlled by using spray type desuperheater which is installed in the RH inlet. steam temperature is controlled by using spray type 5

2.6 Condensate & Feedwater Systems Each unit includes: three condensate water pumps, three Low pressure heaters and two High pressure heaters, one dearator and one steam driven turbine feedwater pump and one electrical feedwater pump. 3. Description of the Existing Control and Data Acquisition Systems 3.1 Burner Management System The Burner Control / Management System's logic is implemented by The BAILEY 762 equipment dated from the early 1970's. The equipment consists of logic cabinets, flame scanners, four oil elevation sections, and eight separate coal elevation sections. The Burner Management System is designed to ensure a safe, orderly startup and shutdown sequence of the fuel firing equipment and to prevent errors of omission and commission during execution of these operating sequences. The System provides safety interlocks to protect against potential emergency situations in the event of malfunction of fuel firing equipment and associated air systems. Boiler Lockout Relay (located in the electrical cabinet) acts parallel to the Burner Management System in order to increase reliability of the comprehensive system. 3.2 The Combustion Control System The main control loops are: Fuel demand; Air demand; Throttled Pressure Control; Boiler Demand Limit Regulator (BDLR); Hard- Runbacks; Feedwater demand; Load demand; Drum-level control, and Heater drain level control. Pulverizer provides feeders' coal flow, primary air flow and temperature control in accordance with fuel demand signal. The primary air flow control is done by primary air flow damper. The a/m fuel demand signal is generated by heat release signal. Primary air control provides primary air fans inlet dampers control on base of total pulverizers' demand with number of pulverizers in service feed forward. 6

Superheat and reheat temperature control provides proper steam temperature by spray valves. The existing combustion control system comprises of four main parts: a. The original 'Leeds and Northrup Co.' (L & N) manufactured DEB-300 dated early 1970's. This part is based on electronic cards that process the Inputs and outputs of the system to and from all the field devices. These electronic cards also include the main and auxiliary control loops for the air, water and fuel control. b. In the 1990's processors based controllers and workstations were added, to mainly accommodate the requirements for Unit Load Runbacks. These DPU's (controllers) include the Front End demands for the main control loops. c. In 2006 the Workstations were upgraded to MAX DNA by Metso (acquired MAX Controls / Leeds & Northrup). The communication network and workstations are common to pairs of units (1+2 and 3+4). d. Field actuators that include drive units by Limitorque 3 phase, L&N one phase, Jordan one phase, Auma 3 phase, controlled by pulsed power switches. 3.3 Data Processing and Monitoring System (DPMS) The existing data acquisition system The DPMS is based on Westinghouse / Emerson hardware and software type WDPF based with Sun workstations. Each unit has about: 9 redundant analog DPU's (data processing units), 5 redundant Digital DPU's, a digital SER (sequence of event recorder) and Fast Analog Recorder, 2 HMI stations, and additional administrative stations, 2,500 digital inputs, 1,200 analog inputs, 220 digital outputs. 7

4. Alternatives for Control Systems IEC has made a preliminary investigation in order to determine the alternatives to provide the control systems' solutions to accommodate the units' retrofit as described above. Following are our preliminary ideas: 4.1 The existing Burner Management System (BMS) has to be replaced by a new BMS, based on modern Digital Technology which will perform the new requirements from the Burner Management System. 4.2 As for the existing Combustion Control System, we are exploring three alternatives: a. Utilizing the existing combustion control system and only adding additional equipment to encompass the new requirements for the retrofit as described above. The new equipment will include the BMS and all the required control equipment to control the equipment installed for the Low NOx Gas Firing. This new control equipment will be interfaced to the existing combustion control system. b. Replacing the complete control system with new digital control equipment integrated completely with the BMS but still utilizing the field equipment (existing L&N supplied drive units). c. Same as alternative 'b' but also replacing the field equipment (drive units). 8

5. Factors Determining the Selected Alternative 5.1 This system is very critical to the functioning of the power plant, still the primary factor determining the chosen alternative will be economic taking into account: - the required high reliability and availability of the system; - life expectancy of 15 years. 5.2 Feasibility of implementing the required control logic in the proposed configuration. The feasibility of interfacing between the different systems. The expected remaining life for the proposed system configuration. The engineering and maintenance Vendor support for the proposed system configuration including the existing system support and also referring to spare parts availability. The feasibility of the utilization of the existing field devices (drive units). 6. Requested Information Vendor is kindly requested to address the following issues: 6.1 The feasibility of the three alternative solutions presented in paragraph 4.2; 6.2 Topics presented under paragraph 5 above. 6.3 The engineering ability of the Vendor to address the above issues. 6.4 The manufacturing ability and maintenance support of the Vendor for the proposed system. 6.5 The proposed system alternative selected by the Vendor. 9

7. Supplier information Company's Name: Telephone No: Fax No: Questionnaire Respondent's Personal Data: Name: Position: Telephone No: e-mail: : Local Representative Information: Company's Name: Contact Person: Telephone No: Fax No: e-mail: : Signature: Date: 10