Application Bulletin



Similar documents
Using HyperTerminal with Agilent General Purpose Instruments

Modbus Communications for PanelView Terminals

Introduction: Implementation of the MVI56-MCM module for modbus communications:

L Firmware And FPGA Configuration Upgrade

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.

Single channel data transceiver module WIZ2-434

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Quectel Cellular Engine

PM1122 INT DIGITAL INTERFACE REMOTE

Software User Guide UG-461

OPERATOR INTERFACE PRODUCTS APPLICATION NOTE. Xycom 4800/2000 OIL (Operator Interface Language)- Series Terminals: Backup and Restore with ProComm

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Knowledge Base POS/C31A Troubleshooting

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

LS-101 LAN to Serial Device server. User s Manual

Date Rev. Details Author

Accessing Diagnostics using a Dialup Modem

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

The Answer to the 14 Most Frequently Asked Modbus Questions

INTRODUCTION FEATURES OF THE ICM

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

Toshiba Serial Driver Help Kepware Technologies

Process Control and Automation using Modbus Protocol

NUM INFORMATION US N 111 1/9

Keep it Simple Timing

Sending SMS Messages and s

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

CONCEPT1 RS232 COMMUNICATION

Liebert IntelliSlot Web Cards

CDI-S100 SERIAL INTERFACE CARD

Application & Quick-Start Guide

T3 Mux M13 Multiplexer

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Software Manual RS232 Laser Merge Module. Document # SU Rev A

Docklight V2.1 User Manual 08/2015. Copyright 2015 Flachmann und Heggelbacher GbR

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4

SCS3205/4805 Quick Start Guide

Introduction. Setting Up the Scanner. Performing Verification Sequence

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

APR-PRT3 Printer Module: C-Bus Programming Instructions

Bill Redirect Software How To Schedule Tasks in Bill Redirect

LTM-1338B. Plus Communications Manual

MATRIX 210. Host Mode Programming

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

Part Number Revision A, January Monitoring System Rack Configuration and Utilities Guide

1 Serial RS232 to Ethernet Adapter Installation Guide

UNIVERSAL POWER-LINE CARRIER SYSTEM TYPE OPU-1

#65 4GHGTGPEG")WKFG #FXCPEGF"6GTOKPCN"5QHVYCTG 8GTUKQP"502 HQT"%QPVTQNNGT/#% Catalog # Rev.02

F2103 GPRS DTU USER MANUAL

LDG Electronics External Meter Serial Communications Protocol Specification

Computer Programming Software Start Guide

FINS Gateway For OMRON PLCs

NortechCommander Software Operating Manual MAN R6

ECcom. Signal Monitor Communications Software Operations Manual

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

How to setup a serial Bluetooth adapter Master Guide

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

EMG Ethernet Modbus Gateway User Manual

PollCat III. Pollable Call Accounting Terminal. User's Guide

COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs

PRT3 Printer Module: ASCII Protocol Programming Instructions

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

IP SERIAL DEVICE SERVER

SETTING UP A REMOTE MODEM CONNECTION Application Note 27

RMCS Installation Guide

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

PPM Users Manual Signature Software

UPS Network Interface. Quick InstallationGuide

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Driver Manual (Supplement to the FieldServer Instruction Manual) FS (Notifier NFS-640 NFS-320 NFS2-640)

MANUAL PC1000R

Vicon Flash Upgrade Software

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

32 Transferring Projects and Data

RS232 Board datasheet

RS-485 Protocol Manual

Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)

WinA4P Configuration Software. Programming Manual for ART, SRT, URT, XRT, ZRT Radio Modems & CRX Receiver

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

SenseLink TM. End-Point Controller. Addendum

ESPA Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

GV-Data Capture V3 Series User's Manual

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Laser Barcode Scanner

Using IDENT M System T with Modbus/TCP

OFF-LINE COMMUNICATIONS WITH CINCINNATI EQUIPMENT Pg. 1 of 5

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Transcription:

INTELLIGENT CONTROLS INC PO BOX 638 34 SPRING HILL RD SACO, ME 04072 U S A Application Bulletin 000-2045 REV. B Retrieving Tap Change Indication Data from an INCON1250B via an SEL 2020 or 2030 Communications Processor Introduction This application guide provides information and settings required to extract Tap Position Indication from an INCON 1250B Programmable Position Monitor via an SEL 2020 / 2030 Communication Processor. To use this application guide, the INCON 1250B must be fitted with the "RS232 SERIAL PORT" option. Refer to INCON 1250B manual for details. INCON 1250B Programmable Position Monitor The INCON 1250B measures the absolute position of a synchro transmitter, commonly known as a Selsyn. It provides both a user definable visual panel indication and optional analog and digital signal outputs suitable for a variety of monitoring and control applications. It is used for Tap Change Position Indication on power transformers in electrical power systems. INCON1250B Serial Port Modes The Serial RS232 (DCE) option on the Model 1250B can be used to program or to retrieve position data from the instrument. There are seven operating modes for the serial RS-232 port. In this application we shall use only the Sampled Mode. This application bulletin assumes that all programming will be done through the front panel buttons. Serial port command line programming of the 1250B is possible, but is not beneficial to this application. Sampled Mode When this mode is selected, the 1250B can be interrogated at any time via the RS-232 port for current position by transmitting a question mark (?) to the 1250B. When the 1250B receives a question mark, it responds by latching the current position and transmitting the value on the display in ASCII form. To select this mode use the front panel menu command OP 51, RS232, SERIAL command to choose mode 3. Setting 1250B Communication Port Parameters Selecting OP80, POrt provides access to the settings for the serial port parameters: (press the UP or Down key to select a value, press the enter key to advance to the next parameter), The communication port settings: baud rate, word length, parity, stop bits, and address are programmable using the front panel menu or via the serial port itself once communication is established. The serial port parameters are shown below. Baud Rate: Default 9600, Valid Selections 2400, 4800, 9600, 14400, 19200, 28800,38400, 57600, 76800 Word Length: Default 8, Valid Selections 7, 8 Parity: Default n, Valid Selections n, E, O Stop Bits: Default 1, Valid Selections 1 or 2 Address (for RS-485 Multi-drop only): Default 128, Valid Selections 0 to 255 sales@incon.com FAX 1-207-283-0158 PAGE 1 of 6

Setting up the INCON 1250B Ensure that the INCON 1250B is connected to a suitable source of supply, powered up, has completed its power up sequence, and is connected to a suitable synchro transmitter. Using the front panel menu as outlined above: Set the RS232 mode (OP 51) to mode 3 (Sampled Mode). Set the INCON 1250B serial port (OP 80) to the default parameters (9600, 8, n, 1, 128). Connections Once the INCON 1250B has been programmed, connect the INCON 1250B serial port to the desired SEL 2020 / 2030 port, via an SEL C223A (9 pin male to 25 pin male DTE-DCE) cable. With this connection in place, once the SEL 2020 / 2030 programming is complete, data retrieval will begin automatically. Note that the INCON1250B RS232 port does not have drive capability to power an SEL 2800 fiber optic transceiver. Setting Up the SEL 2020 / 2030 Ensure that the SEL 2020 / 2030 is connected to a suitable source of supply; powered up and completed its power up sequence. Connect the SEL 2020 / 2030 front port to a PC using an SEL 234A cable and establish communication using HyperTerminal or other appropriate software. Using ACC, and 2AC commands, and appropriate passwords (OTTER & TAIL are default) get to level-2 access on the SEL 2020 /2030. sales@incon.com FAX 1-207-283-0158 PAGE 2 of 6

Set the port on the SEL 2020 / 2030 as shown below (user entries in bold, hints in italics, press the (Enter) key at end of line. If the prompt at any given SEL 2020 / 2030 setting shows that setting is already what you want, just press (Enter). This guide assumes port 5 but any other rear port can be used. *>>set p 5 Port communications settings for Port 5 Device Type (U=Unused, S=SEL IED, O=Other IED, P=Printer, M=Master) DEVICE = O? O Modem Settings Modem Control (Y/N) MODEM = N? (Enter) Attempt to detect port baud rate (Y/N) AUTO_BAUD= N? (Enter) Communications Type (A=ASCII, B=Binary) PROTOCOL= INVALID? A(Enter) Port Identification String PORTID ="rx data"? INCON1250B(Enter) Communications Settings Baud Rate (300, 600, 1200, 2400, 4800, 9600, 19200) BAUD = 2400? 9600(Enter) Number data bits (7,8) DATABIT = 8? 8(Enter) Stop Bits (1,2) STOPBIT = 1? 1(Enter) Parity (N,O,E,1,0) PARITY = N? N(Enter) Enable RTS/CTS handshaking (Y/N) RTS_CTS = N? N(Enter) Enable XON/XOFF flow control (Y/N) XON_XOFF= Y? Y(Enter) Port Timeout in minutes (0.0-120.0) TIMEOUT = 0? 10(Enter) PORT:5 DEVICE = O MODEM = N AUTO_BAUD= N PROTOCOL= A PORTID ="INCON1250B" BAUD = 9600 DATABIT = 8 STOPBIT = 1 PARITY = N RTS_CTS = N XON_XOFF= Y TIMEOUT = 10.0 Save changes (Y/N)? y(enter) sales@incon.com FAX 1-207-283-0158 PAGE 3 of 6

Set up automatic messaging on the appropriate port to send the INCON 1250B sample mode interrogation character "?" every 5 seconds as shown below. *>>SET A 5 Automatic message settings for Port 5 Save Unsolicited Messages (Y/N) AUTOBUF = N?(Enter) Port Startup String STARTUP =? setup\nserial 3\nrun\nexit\n(Enter) Block external connections to this port NOCONN = NA?(Enter) Auto-message Settings How many auto-message sequences (0-12) MSG_CNT = 0? 1(Enter) Item 1 trigger D1 ISSUE1 = NA?P00:00:05.0(Enter) Item 1 message MESG1 = NA??(Enter) (Enter? character for prompt) Item 1 response parsing method (0=IGNORE, 1=ASCII_INT, 2=ASCII_FLOAT, 3=CHAR_STRING, 4=INT_STRING, 5=INT_STRX, 6=FLEX) PARSE1 = 0? 1(Enter) Item 1 number of data items NUM1 = 0? 1(Enter) Time delay to allow response to complete (OFF, ON)DELAY1 = OFF?(Enter) Size of user-defined data space in registers USER = 41?(Enter) AUTOBUF = N STARTUP ="setup\nserial 3\nrun\nexit\n" NOCONN = NA MSG_CNT = 1 ISSUE1 = P00:00:05.0 MESG1 = "?" PARSE1 = 1 NUM1 = 1 DELAY1 = OFF USER = 41 Save changes (Y/N)? Y(Enter) sales@incon.com FAX 1-207-283-0158 PAGE 4 of 6

Notes The STARTUP string is provided just in case the INCON 1250B has been left in the SERIAL Command Mode. If so, the startup string will set it into the Sample Mode ready to respond to the "?" prompt from the SEL 2020 / 2030. If the INCON 1250B is in any other mode, the startup string will have no effect. If this precaution is not considered necessary, STARTUP can be set to the "?" character. The INCON 1250B can be set to detect several neutral positions; 0-1, 0-2, 0-3; 17-1, 17-2 17-3, etc. The number of neutral taps and their numbered position is programmed, depending on the tap changer design. So the query response from the unit is one number most of the time, but two numbers when the LTC is on a neutral tap. This guide assumes that normal operation does not care which neutral tap the LTC is in, and so gathers only the first number. The data will show "0" for any neutral tap on which the INCON 1250B response is "0-n, where n is any other number. The data will show "17" for any neutral tap on which the INCON 1250B response is "17-n, where n is any other number. Checking the data sampling Wait until about 10 seconds after the SEL 2020 / 2030 has completed saving settings and is enabled. Depending on lighting conditions, activity may be observed on the Port 5 Tx and Rx LED. Enter the view command to check the system response as shown below. *>>view 5 d1 Port 5, Data Region INTEGER Data _YEAR = 2004 DAY_OF_YEAR = 237 (08/24) TIME = 17:30:15.093 INTEGER = 14 The response is shown as "INTEGER = ", and in this example assumes the INCON 1250B is measuring tap position 14. The value should match the number displayed on the front panel of the INCON 1250B If the SEL 2020 / 2030 responds with "Data Region Invalid", the SEL 2020 / 2030 did not receive a valid response from the INCON1250B. Check connections cables and check all settings. If still no response, check response of INCON 1250B to manual query by connecting transparently to the INCON 1250B via the SEL 2020 / 2030 as follows. Note that the INCON 1250B will not echo your entries, so the "?" and "Cntrl-D" shown below will not be visible on your PC screen. *>>port 5 Transparent Communications to Port 5 established? 14 (you type question mark?, and the INCON1250B responds with tap number)? 14 Cntrl-D (hold CTRL key down and press "D" once) Transparent Communications to Port 5 terminated. sales@incon.com FAX 1-207-283-0158 PAGE 5 of 6

If the manual query works, but the "View" command still shows invalid, check the port settings and the automatic message settings. If the manual query does not work, check the INCON 1250B port settings, and the cable. Transferring the data to a SCADA system master Once the correct data is shown in the data region of the port, the data can be moved and manipulated via SEL 2020 / 2030 SET M equations to the desired position in the database of a Master port for retrieval by a SCADA master via MODBUS, DNP, or other means. Refer to the SEL 2020 / 2030 instruction manual for SEL 2020 / 2030 specific setting instructions. For assistance with this or any other SEL device issue please call 509-332-1890 and ask for technical assistance from an application engineer. For assistance with this or any other INCON device issue please call 800-984-6266 and ask for technical assistance from an application engineer. sales@incon.com FAX 1-207-283-0158 PAGE 6 of 6