DC INVERTER MULTI-SYSTEM AIR CONDITIONER



Similar documents
DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

HP switch LP switch Discharge thermo Comp. Surface thermo

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

14. Troubleshooting Guide

AIR-CONDITIONER SPLIT TYPE

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Appendix - Controllers 179

USER S MANUAL HSC-24A

Air Conditioners Technical Data

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Failure code manual. content

Operating Instructions Split System Air Conditioner

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

MULTI SPLIT SYSTEM AIR CONDITIONER

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION INSTRUCTION SHEET

Technical service manual

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Technical service manual 2009

PANASONIC TROUBLE SHOOTING GUIDE

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

AIR CONDITIONER INSTALLATION MANUAL

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SWIMMING POOL HEAT PUMP

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

SECTION HEAT PUMPS

york air-conditioning products Residential & VRF News 2015

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Oil and Coolant Circulating Heating System. Model - OCSM

MAC-120HE-01 Air-Cooled Chiller

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Install Guide CT101. Caution. Caution

Air Conditioning System

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

ROOM AIR CONDITIONER INSTALLATION MANUAL

CS-CE9NKE CS-CE12NKE CU-CE9NKE CU-CE12NKE TABLE OF CONTENTS WARNING

ECOCIAT. Domestic hot water heat recovery unit

, User s Manual

Quest 105, Dry155, and 205 Dual

SWIMMING POOL HEAT PUMP Owners Manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

AIR CONDITIONER OUTDOOR UNIT

ALL IN ONE. Heat Pump Water Heater

9ASNA-A SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Meaco 30L and Meaco 40L dehumidifier instruction manual

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Table Z. Troubleshooting Chart for Air Conditioners. Cause

INSTALLATION & OPERATION MANUAL MODULAR AIR COOLED CHILLER

LG Floor Standing Type Air Conditioner INSTALLATION MANUAL

Air Conditioner B B

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

Heat Pump Water Heater IOM Manual

TYPE. MODEL B3200 Roof-Top Air Conditioner used with Mechanical Air Distribution Box INSTALLATION & OPERATING INSTRUCTIONS Air Conditioner

Ceiling Mount Air Handler Manual

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

LOBOY 16 AIR CONDITIONERS

Portable Air Conditioner

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

How To Measure Temperature On A Thermostat

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Transcription:

TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : AEMI0AH AEMIAHB AEMIAH AEMI0AH FILE NO. Destination: Europe DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity.0k.k.k.0k Outdoor Model No. AEMI0AH AEMIAHB AEMIAH AEMI0AH Product Code No. 70 0 ( 9 ) 70 0 ( 9 ) 70 0 7 ( 9 7) 70 0 ( 9 ) AEMI0AH AEMIAHB AEMIAH < Applicable Indoor Units > AEMI0AH all mounted type AMIAHL AMI7AHL AMIAHL AIAHL AIAHL NOTE For details about the combination, refer to "Unit Combination Table" in the Appendix of this manual. RoHS This product does not contain any hazardous substances prohibited by the RoHS Directive. ARNING You are requested to use RoHS compliant parts for maintenance or repair. You are requested to use lead-free solder. F-GAS REGULATION (EC) No / 00 Do not vent R0A into atmosphere : R0A is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global arming Potential (GP) = 97. REFERENCE NO. SM7007

Important! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently. For safe installation and trouble-free operation, you must: Carefully read this instruction booklet before beginning. Follow each installation or repair step exactly as shown. Observe all local, state, and national electrical codes. Pay close attention to all warning and caution notices given in this manual. This symbol refers to a hazard or unsafe practice which can ARNING result in severe personal injury or death. This symbol refers to a hazard or unsafe practice which can CAUTION result in personal injury or product or property damage. If Necessary, Get Help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions. In Case of Improper Installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document. SPECIAL PRECAUTIONS ARNING hen iring ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO IRE THIS SYSTEM. Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked. Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death. Ground the unit following local electrical codes. Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard. Install a protective leakage breaker depending on the installation location (especially a damp or humid location). If a leakage breaker is not installed, electric shock can occur. hen Transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers. hen Installing In a Ceiling or all Make sure the ceiling/wall is strong enough to hold the unit s weight. It may be necessary to construct a strong wood or metal frame to provide added support. In a Room Properly insulate any tubing run inside a room to prevent "sweating" that can cause dripping and water damage to walls and floors. In Moist or Uneven Locations Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration. In an Area with High inds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle. In a Snowy Area (for Heat Pump-type Systems) Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents. hen Connecting Refrigerant Tubing Use the flare method for connecting tubing. Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection. Check carefully for leaks before starting the test run. hen Servicing Turn the power off at the main power box (mains) before opening the unit to check or repair electrical parts and wiring. Keep your fingers and clothing away from any moving parts. Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced. Others CAUTION Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas. Confirm upon completing installation that no refrigerant gas is leaking. If escaped gas comes in contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas.

Table of Contents APPLICABLE INDOOR UNITS... Page. OPERATING RANGE.... SPECIFICATIONS -. Unit Specifications... -. Major Component Specifications... -. Other Component Specifications... 7. DIMENSIONAL DATA.... REFRIGERANT FLO DIAGRAM -. Refrigerant Flow Diagram... 0. PERFORMANCE DATA -. Temperature Charts.... ELECTRICAL DATA -. Electric iring Diagrams... 7. FUNCTIONS 7-. Explanation of Functions... 7-. Protective Functions.... TROUBLESHOOTING -. Precautions before Performing Inspection or Repair... -. Trouble Diagnosis by Error Monitor Lamps... -. Checking the Outdoor System... -. Trouble Diagnosis of Each Part... -. Trouble Diagnosis of Fan Motor... 9. REFRIGERANT R0A: SPECIAL PRECAUTIONS HEN SERVICING UNIT 9-. Characteristics of New Refrigerant R0A... 9-. Checklist before Servicing... 9-. Tools Specifically for R0A... 9-. Tubing Installation Procedures... 9-. In Case of Compressor Malfunction... 9-. In Case Refrigerant is Leaking... 9-7. Charging Additional Refrigerant... 9-. Retro-Fitting Existing Systems... 9 9 9

Page APPENDIX A INSTALLATION INSTRUCTIONS... A- APPENDIX B UNIT COMBINATION TABLES... A-

APPLICABLE INDOOR UNITS Multi-Outdoor Unit Indoor Unit AMIAHL AMI7AHL AMIAHL AIAHL AIAHL -Room AEMI0AH YES YES YES NO NO -Room -Room AEMIAHB YES YES YES YES NO AEMIAH YES YES YES YES YES -Room AEMI0AH YES YES YES YES YES NOTE. The table lists the wall-mounted type of indoor units as representative models.. For details on the applicable indoor units other than the wall-mounted type, refer to the catalog.

. OPERATING RANGE Cooling Heating Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum Minimum Maximum Minimum C D.B. / C.B. 9 C D.B. / C.B. 7 C D.B. C D.B. C D.B. 9 C D.B. C D.B. / C.B. _ D.B. / - C.B.

. SPECIFICATIONS -. Unit Specifications Outdoor Unit AEMI0AH Indoor Unit AMI7AHL Type Number of Connectable Indoor Units Number of Operatable Indoor Units Max. Capacity of Operating Indoor Units Power Source Voltage Rating k -Room Multi Outdoor Unit. 0 to 0V Single-Phase 0Hz 0V Performance Capacity Air Circulation (High) k BTU/h m /h.0,00 Cooling (.0 to.0 ) (,00 to 7,00 ),900.,00 Heating (. to. ) ( 7,00 to,00 ),900 Electrical Rating Cooling Available Voltage Range V 9 to Running Amperes Power Input A. 9 Power Factor % 9 E.E.R. /. C.O.P. / - Compressor Locked Rotor Amperes A. Heating. 9 9 -. Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor Refrigerant / Amount charged at shipment kg DC Twin Rotary (Inverter) R0A /.7 Refrigerant Control Electric Expansion Valve Operation Sound Hi db-a 7 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit m 0 Refrigerant Narrow tube mm (in.). (/") Tube Diameter ide tube mm (in.) 9. (/") Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping mm mm kg kg m 9 790 90.0.0 0. DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : AMI7AHL units Outdoor Unit : AEMI0AH unit. Rating conditions are: Cooling : Indoor air temp. 7 C D.B. / 9 C.B. Heating : Indoor air temp. 0 C D.B. Outdoor air temp. C D.B. / C.B. Outdoor air temp. 7 C D.B. / C.B. 7

Outdoor Unit AEMIAHB Indoor Unit AMI7AHL + AIAHL Type Number of Connectable Indoor Units Number of Operatable Indoor Units Max. Capacity of Operating Indoor Units Power Source Voltage Rating k -Room Multi Outdoor Unit. 0 to 0V Single-Phase 0Hz 0V Performance Capacity Air Circulation (High) k BTU/h m /h. 9,00 Cooling (. to. ) ( 7,00 to,00 ),900 7.,900 Heating (. to. ) (,00 to,700 ),900 Electrical Rating Cooling Available Voltage Range V 9 to Running Amperes Power Input A 7.,9 Power Factor % 9 E.E.R. /.0 C.O.P. / - Compressor Locked Rotor Amperes A. Heating 7.70,7 9 -. Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor Refrigerant / Amount charged at shipment kg DC Twin Rotary (Inverter) R0A /. Refrigerant Control Electric Expansion Valve Operation Sound Hi db-a 0 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit m Refrigerant Narrow tube mm (in.). (/") Tube Diameter ide tube mm (in.) 9. (/") Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping mm mm kg kg m 70 900 0,00.0 9.0 0. DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : AMI7AHL unit + AIAHL unit Outdoor Unit : AEMIAHB unit. Rating conditions are: Cooling : Indoor air temp. 7 C D.B. / 9 C.B. Heating : Indoor air temp. 0 C D.B. Outdoor air temp. C D.B. / C.B. Outdoor air temp. 7 C D.B. / C.B.

Outdoor Unit AEMIAH Indoor Unit AMI7AHL Type Number of Connectable Indoor Units Number of Operatable Indoor Units Max. Capacity of Operating Indoor Units Power Source Voltage Rating k -Room Multi Outdoor Unit. 0 to 0V Single-Phase 0Hz 0V Performance Capacity Air Circulation (High) k BTU/h m /h.,00 Cooling (.9 to. ) ( 9,900 to 7,00 ),900. 9,00 Heating (. to 9.0 ) (,00 to 0,700 ),900 Electrical Rating Cooling Available Voltage Range V 9 to Running Amperes Power Input A.7,000 Power Factor % 9 E.E.R. /.0 C.O.P. / - Compressor Locked Rotor Amperes A. Heating.7,000 9 -.0 Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor Refrigerant / Amount charged at shipment kg DC Twin Rotary (Inverter) R0A /. Refrigerant Control Electric Expansion Valve Operation Sound Hi db-a 0 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit m Refrigerant Narrow tube mm (in.). (/") Tube Diameter ide tube mm (in.) 9. (/") +.7 (/") Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping mm mm kg kg m 70 900 0,00.0 9.0 0. DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : AMI7AHL units Outdoor Unit : AEMIAH unit. Rating conditions are: Cooling : Indoor air temp. 7 C D.B. / 9 C.B. Heating : Indoor air temp. 0 C D.B. Outdoor air temp. C D.B. / C.B. Outdoor air temp. 7 C D.B. / C.B. 9

Outdoor Unit AEMI0AH Indoor Unit AMI7AHL Type Number of Connectable Indoor Units Number of Operatable Indoor Units Max. Capacity of Operating Indoor Units Power Source Voltage Rating k -Room Multi Outdoor Unit.7 0 to 0V Single-Phase 0Hz 0V Performance Capacity Air Circulation (High) k BTU/h m /h.0 7,00 Cooling (.9 to 9. ) ( 9,900 to,00 ),070 9.,00 Heating (. to 9. ) (,00 to,00 ),070 Electrical Rating Cooling Available Voltage Range V 9 to Running Amperes Power Input A 7.,7 Power Factor % 99 E.E.R. /. C.O.P. / - Compressor Locked Rotor Amperes A 7.0 Heating.9,00 99 -. Features (Outdoor Unit) Control Microprocessor Fan Speeds Auto (Hi, Me, Lo) Compressor Refrigerant / Amount charged at shipment kg DC Twin Rotary (Inverter) R0A /. Refrigerant Control Electric Expansion Valve Operation Sound Hi db-a 0 Refrigerant Tubing Connections Flare Type Max. allowable tubing length per unit m 0 Refrigerant Narrow tube mm (in.). (/") Tube Diameter ide tube mm (in.) 9. (/") +.7 (/") Dimensions & eight (Outdoor Unit) Unit Dimensions Package Dimensions eight Height idth Depth Height idth Depth Shipping Volume Net Shipping mm mm kg kg m 90 900 0,09,00.0.0 0. DATA SUBJECT TO CHANGE ITHOUT NOTICE. Remarks:. The Values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : AMI7AHL units Outdoor Unit : AEMI0AH unit. Rating conditions are: Cooling : Indoor air temp. 7 C D.B. / 9 C.B. Heating : Indoor air temp. 0 C D.B. Outdoor air temp. C D.B. / C.B. Outdoor air temp. 7 C D.B. / C.B. 0

-. Major Component Specifications --. Outdoor Unit Outdoor Unit AEMI0AH Control PCB Part No. Controls Control Circuit Fuse CB-CMRVEH Microprocessor 0V A Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Coil Resistance (Ambient Temp. 0 C) cc Ohm Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Run Capacitor Crankcase Heater DC Twin Rotary (Hermetic) C-RVN9H0M /,000 FV0S... 0 R - S : 0. S - T : 0. T - R : 0. Yes Yes Yes CS-7L Operation Temp. Open : C, Close : 9 C Micro F - VAC - - Fan Type Q'ty... Dia. mm Propeller... D0 Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool:Hi / Heat:Hi) Nominal Output Coil Resistance (Ambient Temp. 0 C) Safety Device Type Over-Current Protection Run Capacitor Ohm Micro F VAC DC Motor DAJ-J7-CR... 70 / 70 0 - : 77. - : 77. - : 77. Internal Controller Yes - - Heat Exchanger Coil Coil Rows Fin Pitch mm Face Area m External Finish Aluminum Plate Fin / Copper Tube 0. Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE ITHOUT NOTICE.

Outdoor Unit AEMIAHB Control PCB Part No. Controls Control Circuit Fuse CB-CMRV9EH Microprocessor 0V A Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Coil Resistance (Ambient Temp. 0 C) Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Run Capacitor Crankcase Heater DC Twin Rotary (Hermetic) KD0XAB /,700 cc FV0S... 900 Ohm U - V : 0.70 V - : 0.70 - U : 0.7 Yes Yes Yes CS-7LN Operation Temp. Open : C, Close : 00 C Micro F - VAC - 0V Fan Type Q'ty... Dia. mm Propeller... D0 Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool:Hi / Heat:Hi) Nominal Output Coil Resistance (Ambient Temp. 0 C) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Ohm Micro F VAC DC Motor SIC-7F-D90-... 70 / 70 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fin Pitch mm Aluminum Plate Fin / Copper Tube. Face Area 0.9 m External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE ITHOUT NOTICE.

Outdoor Unit AEMIAH Control PCB Part No. Controls Control Circuit Fuse CB-CMRVEH Microprocessor 0V A Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Coil Resistance (Ambient Temp. 0 C) Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Run Capacitor Crankcase Heater DC Twin Rotary (Hermetic) KD0XAB /,700 cc FV0S... 900 Ohm U - V : 0.70 V - : 0.70 - U : 0.7 Yes Yes Yes CS-7LN Operation Temp. Open : C, Close : 00 C Micro F - VAC - 0V Fan Type Q'ty... Dia. mm Propeller... D0 Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool:Hi / Heat:Hi) Nominal Output Coil Resistance (Ambient Temp. 0 C) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Ohm Micro F VAC DC Motor SIC-7F-D90-... 70 / 70 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fin Pitch mm Aluminum Plate Fin / Copper Tube. Face Area 0.9 m External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE ITHOUT NOTICE.

Outdoor Unit AEMI0AH Control PCB Part No. Controls Control Circuit Fuse CB-CMRVEH Microprocessor 0V A Compressor Type Compressor Model / Nominal Output Compressor Oil... Amount Coil Resistance (Ambient Temp. 0 C) Safety Device CT (Peak current cut-off control) Compressor Discharge Temp. Control Operation cut-off control in abnormal ambient Temp. Overload Relay Model Run Capacitor Crankcase Heater DC Twin Rotary (Hermetic) JD0XAB /,000 cc FV0S...,00 Ohm U - V : 0. V - : 0. - U : 0. Yes Yes Yes CS-7LN Operation Temp. Open : C, Close : 00 C Micro F - VAC - 0V Fan Type Q'ty... Dia. mm Propeller... D0 Fan Motor Type Model... Q'ty No. of Poles Rough Measure RPM (Cool:Hi / Heat:Hi) Nominal Output Coil Resistance (Ambient Temp. 0 C) Safety Device Type Over-Current Protection Over-Heat Protection Run Capacitor Ohm Micro F VAC DC Motor SIC-7F-D90-... 70 / 70 90 - Internal Controller Yes Yes - - Heat Exchanger Coil Coil Rows Fin Pitch mm Aluminum Plate Fin / Copper Tube. Face Area 0.7 m External Finish Acrylic baked-on enamel finish DATA SUBJECT TO CHANGE ITHOUT NOTICE.

-. Other Component Specifications Sensor Name Model No. of sensor Quantity of Sensor AEMI0AH AEMIAHB AEMIAH AEMI0AH Outdoor air temp sensor TKS9B Outdoor heat exchanger sensor TKS9B A / AN sensor TKS9B / / / / B / BN sensor TKS9B / / / / C / CN sensor TKS9B 0 0 / / D / DN sensor TKS9B 0 0 / / 0 Resistance (k ohm) 0 0 0 0-0 - -0-0 0 0 Temperature ( C) Sensor Name Model No. of sensor Quantity of Sensor AEMI0AH AEMIAHB AEMIAH AEMI0AH Compressor temp sensor TKS9B Resistance (k ohm) 00 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 70 0 90 Temperature ( C)

. DIMENSIONAL DATA Outdoor Unit AEMI0AH 0 -ID: -ID:. 9 0 ID: Narrow tube service valve dia.. (/") 790 70 ide tube service valve dia.9. (/") 70 70 9 Unit: mm

Outdoor Unit AEMIAHB 0 9 ID: -ID:. 0 9 Narrow tube service valve dia.. (/") 900 ide tube service valve dia.9. (/") 0 7 7 70 Unit: mm 7

Outdoor Unit AEMIAH 0 9 ID: -ID:. 0 9 ide tube service valve dia..70 (/") Narrow tube service valve dia.. (/") 900 ide tube service valve dia.9. (/") 70 0 7 70 70 7 70 70 Unit: mm

Outdoor Unit AEMI0AH 0 9 ID: -ID:. 0 9 ide tube service valve dia..70 (/") Narrow tube service valve dia.. (/") 900 ide tube service valve dia.9. (/") 0 7 70 70 7 70 70 90 Unit: mm 9

. REFRIGERANT FLO DIAGRAM -. Refrigerant Flow Diagram Outdoor Unit AEMI0AH Indoor unit Outdoor unit ide tube O.D.9.mm O.D.9.mm Service valve on wide tube B A Muffler Sub accumulator Main accumulator Compressor -way valve Defrost valve for hot gas bypass S Heat exchanger Narrow tube O.D..mm O.D..mm Service valve on narrow tube BN AN Strainer Electric expansion valve M M Capillary tube for split flow Cooling cycle Heating cycle Defrosting cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min. mm. Thickness: Min. mm Insulation Thickness: Min. mm CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. ide tube Narrow tube 0

Outdoor Unit AEMIAHB Indoor unit Outdoor unit ide tube O.D.9.mm O.D.9.mm Service valve on wide tube B A Header Sub accumulator Main accumulator Compressor -way valve Defrost valve for hot gas bypass S Heat exchanger Narrow tube O.D..mm O.D..mm Service valve on narrow tube BN AN Strainer Electric expansion valve M M Header Cooling cycle Heating cycle Defrosting cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min. mm. Thickness: Min. mm Insulation Thickness: Min. mm CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. ide tube Narrow tube

Outdoor Unit AEMIAH Indoor unit Outdoor unit ide tube O.D.9.mm O.D.9.mm O.D.9.mm O.D..7mm Service valve on wide tube D C B A Header -way valve Sub accumulator Main accumulator Compressor Narrow tube O.D..mm O.D..mm O.D..mm O.D..mm Service valve on narrow tube DN CN BN AN Strainer Electric expansion valve M M M M Header Defrost valve for hot gas bypass S Heat exchanger Cooling cycle Heating cycle Defrosting cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min. mm. Thickness: Min. mm Insulation Thickness: Min. mm CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. ide tube Narrow tube

Outdoor Unit AEMI0AH Indoor unit Outdoor unit ide tube O.D.9.mm O.D.9.mm O.D..7mm O.D..7mm Service valve on wide tube D C B A Header -way valve Sub accumulator Main accumulator Compressor Narrow tube O.D..mm O.D..mm O.D..mm O.D..mm Service valve on narrow tube DN CN BN AN Strainer Electric expansion valve M M M M Header Defrost valve for hot gas bypass S Heat exchanger Cooling cycle Heating cycle Defrosting cycle Insulation of Refrigerant Tubing IMPORTANT Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min. mm. Thickness: Min. mm Insulation Thickness: Min. mm CAUTION After a tube has been insulated, never try to bend it into a narrow curve because it can cause the tube to break or crack. ide tube Narrow tube

. PERFORMANCE DATA -. Temperature Charts --. Temperature Charts (AEMI0AH) Outdoor Unit AEMI0AH Indoor Unit AMIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.). (.) Lo fan Hi fan Indoor air temp.0 C 7 C C.0 (0.). 0 0 (.) - 0 0 0 () Operating current performance chart () Operating current performance chart High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.).0 (0.) Indoor air temp. C 0 C 7 C Lo fan Hi fan Operating current (A) Indoor air temp.0 C 7 C C Operating current (A) Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Indoor air temp.0 C 7 C C Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMI0AH Indoor Unit AMI7AHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.). (.).0 (0.) Lo fan Hi fan Indoor air temp.0 C 7 C C 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.) Indoor air temp. C 0 C 7 C.0 (0.)- 0 0 0 () Operating current performance chart () Operating current performance chart Lo fan Hi fan 7 Operating current (A) Indoor air temp.0 C 7 C C Operating current (A) Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart 0 Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Indoor air temp.0 C 7 C C Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMI0AH Indoor Unit AMIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.).0 (0.) 0. (.) Lo fan Hi fan Indoor air temp.0 C 7 C C 0 0 High pressure at wide tube service valve MPaG (kgf/cm G).0 (0.). (.7).0 (0.) Indoor air temp. C 0 C 7 C. (.)- 0 0 0 () Operating current performance chart () Operating current performance chart Operating current (A) Lo fan Hi fan Indoor air temp.0 C 7 C C Operating current (A) 7 Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Indoor air temp.0 C 7 C C Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

--. Temperature Charts (AEMIAHB) Outdoor Unit AEMIAHB Indoor Unit AMIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.). (.).0 (0.) Lo fan Hi fan HH fan Indoor air temp.0 C 7 C C 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.) Indoor air temp. C 0 C 7 C.0 (0.) - 0 0 0 () Operating current performance chart () Operating current performance chart Lo fan Hi fan HH fan Operating current (A) Indoor air temp.0 C 7 C C Operating current (A) 7 Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart 0 Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan HH fan Indoor air temp.0 C 7 C C Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary. 7

Outdoor Unit AEMIAHB Indoor Unit AMI7AHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.). (.).0 (0.) Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.) Indoor air temp. C 0 C 7 C.0 (0.)- 0 0 0 () Operating current performance chart () Operating current performance chart Lo fan Hi fan HH fan Operating current (A) Indoor air temp.0 C 7 C C Operating current (A) 7 Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart 0 Indoor discharge air temperature ( C) 0 Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMIAHB Indoor Unit AMIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.).0 (0.) 0.9 (9.) Lo fan Hi fan Indoor air temp.0 C 7 C C 0 0 HH fan - 0 0 0 () Operating current performance chart () Operating current performance chart High pressure at wide tube service valve MPaG (kgf/cm G).0 (0.). (.7).0 (0.). (.) Indoor air temp. C 0 C 7 C 0 Operating current (A) Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Operating current (A) 9 7 Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart 0 Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Indoor discharge air temperature ( C) 0 0 0 0 C Indoor air temp. C 7 C 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary. 9

Outdoor Unit AEMIAHB Indoor Unit AIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.).0 (0.) 0.9 (9.) Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan 0 0 High pressure at wide tube service valve MPaG (kgf/cm G).0 (0.). (.7).0 (0.) Indoor air temp. C 0 C 7 C. (.) - 0 0 0 () Operating current performance chart () Operating current performance chart Lo fan Hi fan HH fan Operating current (A) 7 Indoor air temp.0 C 7 C C Operating current (A) 0 9 Indoor air temp. C 0 C 7 C 7 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary. 0

--. Temperature Charts (AEMIAH) Outdoor Unit AEMIAH Indoor Unit AMIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.). (.).0 (0.) Lo fan Hi fan HH fan Indoor air temp.0 C 7 C C 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.) Indoor air temp. C 0 C 7 C.0 (0.) - 0 0 0 () Operating current performance chart () Operating current performance chart Lo fan Hi fan HH fan Operating current (A) Indoor air temp.0 C 7 C C Operating current (A) 7 Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart 0 Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan HH fan Indoor air temp.0 C 7 C C Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMIAH Indoor Unit AMI7AHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.). (.).0 (0.) Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.) Indoor air temp. C 0 C 7 C.0 (0.)- 0 0 0 () Operating current performance chart () Operating current performance chart Lo fan Hi fan HH fan Operating current (A) Indoor air temp.0 C 7 C C Operating current (A) 7 Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart 0 Indoor discharge air temperature ( C) 0 Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMIAH Indoor Unit AMIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.).0 (0.) 0.9 (9.) Lo fan Hi fan Indoor air temp.0 C 7 C C 0 0 HH fan - 0 0 0 () Operating current performance chart () Operating current performance chart High pressure at wide tube service valve MPaG (kgf/cm G).0 (0.). (.7).0 (0.). (.) Indoor air temp. C 0 C 7 C 0 Operating current (A) Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Operating current (A) 9 7 Indoor air temp. C 0 C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart 0 Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Indoor discharge air temperature ( C) 0 0 0 0 C Indoor air temp. C 7 C 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMIAH Indoor Unit AIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.).0 (0.) 0.9 (9.) Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan 0 0 High pressure at wide tube service valve MPaG (kgf/cm G).0 (0.). (.7).0 (0.) Indoor air temp. C 0 C 7 C. (.) - 0 0 0 () Operating current performance chart () Operating current performance chart Lo fan Hi fan HH fan Operating current (A) 7 Indoor air temp.0 C 7 C C Operating current (A) 0 9 Indoor air temp. C 0 C 7 C 7 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMIAH Indoor Unit AIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.). (.).0 (0.) 0.9 (9.) Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan 0 0 High pressure at wide tube service valve MPaG (kgf/cm G).0 (0.). (.7).0 (0.) Indoor air temp. C 0 C 7 C. (.) - 0 0 0 () Operating current performance chart () Operating current performance chart Operating current (A) 9 7 Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Operating current (A) 0 Indoor air temp. C 0 C 7 C 9 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Indoor air temp.0 C 7 C C HH fan Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

--. Temperature Charts (AEMI0AH) Outdoor Unit AEMI0AH Indoor Unit AMIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.).0 (0.) 0. (.) 0. (.) Lo fan Hi fan Hi fan HH fan Indoor air temp.0 C 7 C C 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.).0 (0.) 0 C Indoor air temp. C 7 C. (.) - 0 0 0 () Operating current performance chart () Operating current performance chart Lo fan Hi fan Hi fan HH fan 9 Operating current (A) Indoor air temp.0 C 7 C C Operating current (A) 7 0 C Indoor air temp. C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Hi fan HH fan Indoor air temp.0 C 7 C C 0 0 Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMI0AH Indoor Unit AMI7AHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.).0 (0.) 0. (.) 0. (.) Lo fan Hi fan Hi fan HH fan Indoor air temp.0 C 7 C C 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.).0 (0.) 0 C Indoor air temp. C 7 C. (.) - 0 0 0 () Operating current performance chart () Operating current performance chart Operating current (A) Lo fan Hi fan Hi fan HH fan Indoor air temp.0 C 7 C C Operating current (A) 7 0 C Indoor air temp. C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Hi fan HH fan Indoor air temp.0 C 7 C C 0 0 Indoor discharge air temperature ( C) 0 0 C Indoor air temp. C 7 C 0 0 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary. 7

Outdoor Unit AEMI0AH Indoor Unit AMIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.).0 (0.) 0. (.) 0. (.) Lo fan Hi fan Hi fan HH fan Indoor air temp.0 C 7 C C 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.).0 (0.) Indoor air temp. C 0 C 7 C. (.) - 0 0 0 () Operating current performance chart () Operating current performance chart Operating current (A) Lo fan Hi fan Hi fan HH fan 7 C Indoor air temp.0 C C Operating current (A) 0 9 0 C 0 C Indoor air air temp. C temp. C 7 C 7 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Hi fan Hi fan HH fan Indoor air temp.0 C 7 C C 0 0 Indoor discharge air temperature ( C) 0 0 0 Indoor air temp. C 0 C 7 C 0-0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary.

Outdoor Unit AEMI0AH Indoor Unit AIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.).0 (0.) 0. (.) 0. (.) Lo fan Indoor air temp.0 C 7 C C Hi fan 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.).0 (0.) Indoor air temp. C 0 C 7 C. (.) - 0 0 0 () Operating current performance chart () Operating current performance chart Operating current (A) 9 7 Lo fan 7 C Indoor air temp.0 C C Hi fan Operating current (A) 0 C 0 C Indoor Indoor air temp. C temp. C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Indoor air temp.0 C 7 C C 0 0 Hi fan Indoor discharge air temperature ( C) 0 0 0 0 Indoor air temp. C 0 C 7 C - 0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary. 9

Outdoor Unit AEMI0AH Indoor Unit AIAHL Cooling Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) Heating Characteristics (RH : %, Indoor fan speed : High fan) (0V, 0Hz) () Low pressure performance chart () High pressure performance chart Low pressure at wide tube service valve MPaG (kgf/cm G). (.).0 (0.) 0. (.) 0. (.) Lo fan Indoor air temp.0 C 7 C C Hi fan 0 0 High pressure at wide tube service valve MPaG (kgf/cm G). (.7).0 (0.). (.).0 (0.) Indoor air temp. C 0 C 7 C. (.) - 0 0 0 () Operating current performance chart () Operating current performance chart Operating current (A) 0 9 Lo fan 7 C Indoor air temp.0 C C Hi fan Operating current (A) 0 C 0 C Indoor Indoor air temp. C temp. C 7 C 0 0-0 0 0 () Indoor discharge air performance chart () Indoor discharge air performance chart Indoor discharge air temperature ( C) 0 0 Lo fan Indoor air temp.0 C 7 C C 0 0 Hi fan Indoor discharge air temperature ( C) 0 0 0 0 Indoor air temp. C 0 C 7 C - 0 0 0 NOTE This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type. Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.) The performance is for a tubing length of 7. m. If the tubing length is different, the performance chart will vary. 0

. ELECTRICAL DATA -. Electric iring Diagrams Outdoor Unit AEMI0AH ARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. CONTROLLER REACTANCE COMPRESSOR THERMISTOR (P) CONNECTOR COIL THERMISTOR OUTDOOR THERMISTOR (7P) CONNECTOR (P) CONNECTOR ORG ORG GRY GRY N L POER SUPPLY B INDDOR UNIT A INDDOR UNIT TO INDDOR UNIT (P) CONNECTOR (P) CONNECTOR COIL/OUTDOOR COMP MV0 MAGNETIC COIL TERMINAL PLATE 7 GND A-TH (P) CONNECTOR A THERMISTOR AN THERMISTOR (P) CONNECTOR B THERMISTOR BN THERMISTOR COIL DEFROST VALVE DEF B-TH DEF DEF0 MV0 (P) CONNECTOR (P) CONNECTOR COIL AY VALVE RV RV RV0 MAGNETIC COIL L L E- E- (P) CONNECTOR ORG ORG GRY GRY CN0 DCFM 7 7 FAN MOTOR MV MV (P) CONNECTOR GRN/ GRN/ GRN/ (OLR) OVERLOAD RELAY OLR0 OLR U V COMPRESSOR MOTOR CM C S R GRN/ (PNK) FERRITE CORE (P)CONNECTOR (PNK) 7 FM E ACIN A ACIN SI-A SI-B REACTANCE FA-7-900-

Outdoor Unit AEMIAHB ARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. ORG GRY N L POER SUPPLY B INDDOR UNIT A INDDOR UNIT TO INDDOR UNIT REACTANCE CONTROLLER HEATER CRANKCASE (P) CONNECTOR MV0 MAGNETIC COIL REACTANCE TERMINAL PLATE 7 GND ORG BRN ORG BRN 7 7 (P) CONNECTOR FERRITE CORE S/U C/ FM R/V CM FAN MOTOR COMPRESSOR MOTOR FERRITE CORE COMPRESSOR THERMISTOR (PNK) (PNK) COIL/OUTDOOR COMP COIL THERMISTOR OUTDOOR THERMISTOR A THERMISTOR AN THERMISTOR B THERMISTOR BN THERMISTOR (P) CONNECTOR (P) CONNECTOR COIL DEFROST VALVE COIL AY VALVE DEF RV (P) CONNECTOR A-TH B-TH DEF DEF0 RV RV0 L L E- E- CN0 DCFM MV 7 MV0 ORG GRY (P) CONNECTOR GRN/ GRN/ GRN/ (OLR) OVERLOAD RELAY OLR0 OLR U V HEATER HEATER0 GRN/ MV MAGNETIC COIL ACIN E A ACIN SI-A SI-B FA-7-00-0

Outdoor Unit AEMIAH ARNING To avoid electrical shock hazard, be sure to disconnect power before checking, servicing and/or cleaning any electrical parts. (P) CONNECTOR OVERLOAD RELAY (OLR) CONTROLLER REACTANCE COMPRESSOR THERMISTOR COIL THERMISTOR OUTDOOR THERMISTOR COIL/OUTDOOR COMP A-TH COIL DEFROST VALVE DEF A THERMISTOR AN THERMISTOR B THERMISTOR BN THERMISTOR (P) CONNECTOR (P) CONNECTOR B-TH DEF DEF0 COIL AY VALVE RV (P) CONNECTOR GRN/ GRN/ GRN/ OLR0 OLR U V E A GND A INDDOR UNIT B INDDOR UNIT C INDDOR UNIT 7 9 D INDDOR UNIT N L POER SUPPLY TO INDDOR UNIT BRN GRY ACIN ACIN SI-A SI-B REACTANCE FERRITE CORE 0 GND R/V (PNK) (P) CONNECTOR FERRITE CORE (PNK) S/U CM C/ GRN/ COMPRESSOR MOTOR (P) CONNECTOR CRANKCASE HEATER RV RV0 HEATER HEATER0 L L E- E- SICOM MV MV0 ORG GRY ORG GRY ORG GRY C-TH MV MV MAGNETIC COIL MV SI-D SI-C MAGNETIC COIL MAGNETIC COIL MV MAGNETIC COIL ORG GRY ORG BRN ORG BRN CN0 DCFM 7 7 7 FM FAN MOTOR 7 KS 7 KS 7 CN0 CN0 D-TH KS0 CN0 SICOM MV MV0 D THERMISTOR DN THERMISTOR C THERMISTOR CN THERMISTOR TERMINAL PLATE FA-7-700-0