Chapter 4 Using Line Power Analysis



Similar documents
Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Oscilloscope, Function Generator, and Voltage Division

Electromagnetic Compatibility (EMC) Low-Frequency Standards. Standards on Low-Frequency Emission: IEC

Dash 18X / Dash 18 Data Acquisition Recorder

FREQUENCY RESPONSE ANALYZERS

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Lab 1: The Digital Oscilloscope

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

EXPERIMENT NUMBER 8 CAPACITOR CURRENT-VOLTAGE RELATIONSHIP

Dash 8Xe / Dash 8X Data Acquisition Recorder

PCM Encoding and Decoding:

Quick Connect. quick - simple - efficient.

HVDP. High Voltage Dynamic Power supply/source. 1, 2.5 and 5kW Output DC + Sine Wave Family

Numerical Parameters Analysis of Boonton 4540 Peak Power Meter

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

NEW PRODUCT ANNOUCEMENT

Power System Harmonics

Physics 120 Lab 6: Field Effect Transistors - Ohmic region

Keysight 14585A Control and Analysis Software

Energy Management Energy Meter Type EM23 DIN

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

TESLA Recorder Power Metering Setup Configuration for 3 and 2 Element Watt/VAR Metering

Spectrum Analyzer. Software Instruction Manual

Power Electronics Testings

The Basics of Digital Multimeters

Experiment 2 Diode Applications: Rectifiers

DSO Nano v3 - Wiki. Contents. Introduction

Timing Errors and Jitter

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS

SL Series AC and DC Electronic Loads

Test & Data Management Software

7-41 POWER FACTOR CORRECTION

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

Facilities. Facility Power Monitoring: Or, Where Did All the Electrons Go? Technology & Development Program. Permanent and Temporary Metering

Fluke 125. Users Manual. Industrial ScopeMeter

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

Pop-up Surveillance Camera On Your TV

Analogue/Digital Analogue and Differential Oscilloscopes

Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17

ENERGY STAR Program Requirements Product Specification for Data Center Storage. Draft 2 Test Method March 2013

Titelgrau belassen! Leere Vorlage

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

TDMS Test & Data Management Software

(3 )Three Phase Alternating Voltage and Current

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

Power Log PC Application Software

MATERIALS. Multisim screen shots sent to TA.

Three phase circuits

Agilent Technologies 3000 Series Oscilloscopes

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Fieldbus slave modules with I/Os, DIO

MATRIX TECHNICAL NOTES

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

USB 2.0/3.0 Droop/Drop Test Fixture

Advanced Power Measurement and Analysis Software DPOPWR Datasheet

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Fundamentals of Electrical Power Measurement

15 Series - Electronic step relay and dimmer. Features SERIE

How To Use A Power Supply On A Powerline 2.2 (Ai)

Power Quality Standards for Electric Service

CHAPTER 11: Flip Flops

User Manual. TDS 200-Series Digital Real-Time Oscilloscope

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

INDUCTION MOTOR PERFORMANCE TESTING WITH AN INVERTER POWER SUPPLY, PART 2

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

2.6. In-Laboratory Session QICii Modelling Module. Modelling Module Description

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

Fluke 434/435. Users Manual. Three Phase Power Quality Analyzer

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Lab Exercise 1: Acoustic Waves

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

#AS148 - Automated ECG Analysis

Embest DSO2300 USB Oscilloscope

isim ACTIVE FILTER DESIGNER NEW, VERY CAPABLE, MULTI-STAGE ACTIVE FILTER DESIGN TOOL

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Fundamentals of Power

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

RLC Series Resonance

Lab 3: Introduction to Data Acquisition Cards

Application/Connection Examples

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

Yamaha Power Amplifier. White Paper

Laboratory Start-Up Procedure

Technical Data. back-up time in minutes 100% load % load

DIGITAL PC SCOPE. Total solder points: 625 Difficulty level: beginner advanced K8031 ILLUSTRATED ASSEMBLY MANUAL

Finding What You Need... 4 Setting Up the Wireless Network Feature... 6 Practice Using the Touchscreen Display... 15

Product Data Bulletin

FFT Spectrum Analyzers

AND8433/D. Using ON Semiconductor Constant Current Regulator (CCR) Devices in AC Applications APPLICATION NOTE

U1602A Handheld Oscilloscopes, 20 MHz

Development of an Electrical Power Quality Monitor Based on a PC

Experiment 8 : Pulse Width Modulation

Desktop and Integrated Desktop Computer Product Environmental Information Declaration Form for COMMISSION REGULATION (EC) No 617/2013

Transcription:

Chapter 4 Using Line Power Analysis Line Power Analysis Overview The Line Power Analysis section of PMA1 provides the user with tools to measure 50 and 60 Hz line voltage (V RMS ), line current I RMS ), Apparent Power (VA), Real Power (Watts), and Power Factor (cos 0), as well as evaluate harmonic currents injected into the power line. Harmonic measurements are made in relationship to the requirements of standard EN60001-3-2. EN61000-3-2 The user is encouraged to refer to the latest version of EN61000-3-2 for full definitions and limits set forth by the standard. The following is provided for convenience. Classification of Equipment: For purposes of harmonic current limitation, EN61000-3-2 classifies equipment as follows: Class A: Class B: Class C: Class D: Balanced three-phase equipment and all other equipment, except that stated in one of the following classes. Portable tools. Lighting equipment, including dimming devices. Equipment not in Classes B, C, or motor driven and having an input current with a special wave shape as defined in the following figure: i. i pk 1 π/3 π/3 π/3 CL 0.35 0 0 π/2 π ωt Equipment is deemed to be Class D if the input current wave shape of each half-period is within the figure s envelope for at least 95% of the time. The input current s peak value defines the envelope s centerline, CL. 4-1

Configuring for Line Power Analysis SETUP: To make line power analysis measurements, the equipment should be set up as follows. In the examples below, Channel 2 is used for voltage and Channel 3 is used for current. Any channel can be used for voltage or current. In the case of 3φ systems, multiple voltage and/or current channels can be set up before analysis is started. Current Probe H Line Power Source L Differential Voltage Probes Equipment Under Test EQUIPMENT UNDER TEST: The equipment being tested for power consumption and line harmonics. LINE POWER SOURCE: The power source should be low distortion. EN61000-3-2 specifies maximum crest factor and harmonic distortion for the power source while it is connected to the EUT. The test can be run with the available power line, but the distortion in the source will directly affect the quality of the measurements. 4-2

Initial Setup The Line Voltage and Current Signals Set up a stable display of the line voltage and current signals similar to those shown. V/div setting will depend on the particular line voltage being tested. Set the time/div, trigger delay, trigger level, and voltage channel coupling to obtain a display similar to that shown above. Polarity of the current waveform must match that of the voltage waveform. 4-3

Finishing the Setup and Making Line Power Measurements After the measurement is planned and the voltage and current channels are connected and preliminarily set up, use the PMA1 software to finish the setup and make the line power measurements. Activating the Line Power Analysis Menu Press the MEASURE TOOLS (LT Series) or CURSORS/MEASURE (LC Series) button on the DSO front panel to bring up the MEASURE menu, which includes the Power Measurement selection. MEASURE TOOLS CURSORS/ MEASURE Follow the menu sequence given below: In the Setup List menu, select Voltage Input. 4-4

Selecting the Voltage and Current Channels Press the Voltage Input channel. to select the previously set up line voltage signal In the Setup List menu, select Current Input. Press the Current Input to select the previously set up line current signal channel. The channel selected as the Current Input channel will be assigned Ampere units even if a voltage or nonprobus-compatible current probe is used. Remove and degauss the current probe. Polarity of the current probe should match the voltage waveform. 4-5

Line Power Measurement After the Voltage Input and Current Input selections have been made, press the RETURN on the DSO front panel to bring up the following display: This display screen shows the line voltage and current waveform, as well as the power and energy waveforms. Parameters displayed are: Line Voltage {crms (2)} Line Current {crms (3)} Real Power {rpwr (2,3)} Apparent Power {apwr (2,3)} Power Factor {pf (2,3)} (readout is in milli-units) Menu selections are provided for the user to select the class of the equipment under test (EN61000 A, B, C, or D classification) and the line frequency at which it is operating (50 or 60 Hz). 4-6

Line Harmonics Measurement Before evoking the Measure Harmonics menu selection: Press the Class equipment class. to select the proper EN61000-3-2 Press the Frequency to select the line frequency (50 Hz or 60 Hz) upon which the equipment under test is operating. Press the Units to select Amps or dbua units for the harmonic displays. If changes are needed in the voltage or current input setups, pressing the Setup Inputs will return to the previous menu where the selections can be changed. After the above selections are made, press the Measure Harmonics the following display: to bring up Press the Measure Power to return to the Measure Power Display (changes in class and line frequency can be made there). Press the Show Table to change to the tabular display. Turn the cursor Position to move the cursor along the harmonics (trace should be stopped before using the cursor). 4-7

The Measure Harmonics Displays Line Current waveform Harmonics that exceed limits are shown extending beyond the template. EN61000-3-2 equipment class and line frequency selections are displayed. Frequency cursor readout (trace should be STOPPED) Toggle between display formats by pressing this button. Harmonics above the limits are shown as FAILED. 4-8

Clearing the Line Power Analysis Setup After using the Modulation Analysis section of PMA1, it is important to clear the channel assignments and other alterations that were made while making line power measurements. Press the RETURN until the on-screen menu is cleared. Then press the MEASURE/TOOLS to bring up the MEASURE menu. Press Press RETURN MEASURE TOOLS Selecting Application OFF in the Power Measure menu changes the Voltage Input and Current Input assignments to NONE. The assignment of Ampere units to the channel selected as the Current Input channel will also be removed. 4-9