Cloud Computing Data Centers



Similar documents
Design of Warehouse Scale Computers (WSC)

Green Computing: Datacentres

Green Computing: Datacentres

Concepts Introduced in Chapter 6. Warehouse-Scale Computers. Important Design Factors for WSCs. Programming Models for WSCs

COM 444 Cloud Computing

Chapter 7: Distributed Systems: Warehouse-Scale Computing. Fall 2011 Jussi Kangasharju

Benefits of. Air Flow Management. Data Center

Ch. 4 - Topics of Discussion

- White Paper - Data Centre Cooling. Best Practice

The New Data Center Cooling Paradigm The Tiered Approach

HPC TCO: Cooling and Computer Room Efficiency

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Data Center Cooling A guide from: Your partners in UPS Monitoring Systems

Data Center Components Overview

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Data Center Equipment Power Trends

Benefits of Cold Aisle Containment During Cooling Failure

Data center upgrade proposal. (phase one)

How To Build A Cloud Server For A Large Company

Managing Data Centre Heat Issues

DataCenter 2020: first results for energy-optimization at existing data centers

EHDC. Cooling system for Data Center and server cabinets.

Best Practices in HVAC Design/Retrofit

How Row-based Data Center Cooling Works

Enabling Technologies for Distributed and Cloud Computing

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Enabling Technologies for Distributed Computing

Small Data / Telecommunications Room on Slab Floor

Data Center Cooling & Air Flow Management. Arnold Murphy, CDCEP, CDCAP March 3, 2015

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

Introduction to Datacenters & the Cloud

Reducing Room-Level Bypass Airflow Creates Opportunities to Improve Cooling Capacity and Operating Costs

Power and Cooling for Ultra-High Density Racks and Blade Servers

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

The CEETHERM Data Center Laboratory

The Datacenter as a Computer. An Introduction to the Design of Warehouse-Scale Machines

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

BRUNS-PAK Presents MARK S. EVANKO, Principal

Data Center Power Consumption

How To Write An Article On An Hp Appsystem For Spera Hana

Data Center Energy Profiler Questions Checklist

Last time. Data Center as a Computer. Today. Data Center Construction (and management)

Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

How To Power And Cool A Data Center

Data Center Technology: Physical Infrastructure

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Dealing with Thermal Issues in Data Center Universal Aisle Containment

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Element D Services Heating, Ventilating, and Air Conditioning

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Direct Fresh Air Free Cooling of Data Centres

How to Build a Data Centre Cooling Budget. Ian Cathcart

Rack Hygiene. Data Center White Paper. Executive Summary

An Introduction to Cold Aisle Containment Systems in the Data Centre

Center Thermal Management Can Live Together

Zadara Storage Cloud A

Great Lakes Data Room Case Study

(Examples of various colocation sites)

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Lecture 24: WSC, Datacenters. Topics: network-on-chip wrap-up, warehouse-scale computing and datacenters (Sections )

Improving Data Center Energy Efficiency Through Environmental Optimization

Driving Data Center Efficiency Through the Adoption of Best Practices

EXPERIMENTAL CHARACTERIZATION OF TRANSIENT TEMPERATURE EVOLUTION IN A DATA CENTER FACILITY

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

OCTOBER Layer Zero, the Infrastructure Layer, and High-Performance Data Centers

UCS M-Series Modular Servers

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

Cisco UCS and Fusion- io take Big Data workloads to extreme performance in a small footprint: A case study with Oracle NoSQL database

White Paper Rack climate control in data centres

QUALITATIVE ANALYSIS OF COOLING ARCHITECTURES FOR DATA CENTERS

Hadoop Size does Hadoop Summit 2013

MEGWARE HPC Cluster am LRZ eine mehr als 12-jährige Zusammenarbeit. Prof. Dieter Kranzlmüller (LRZ)

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Reference Design: Scalable Object Storage with Seagate Kinetic, Supermicro, and SwiftStack

Intel Cluster Ready Appro Xtreme-X Computers with Mellanox QDR Infiniband

Airflow Utilization Efficiency (AUE) Can we cool today s servers with airflow?

Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes

Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation

Transcription:

Cloud Computing Data Centers Dr. Sanjay P. Ahuja, Ph.D. 2010-14 FIS Distinguished Professor of Computer Science School of Computing, UNF

Warehouse-Scale Data Center (WSC) Design.

Example: a data center with 2000 servers, each with 8 GB DRAM and four 1 TB disk drives. Each group of 40 servers is connected through a 1 Gbps link to a rack-level switch that has an additional eight 1 Gbps ports for connecting the rack to the cluster-level switch. Warehouse-Scale Data Center Design The cloud is built on massive datacenters. Datacenters as large as a shopping mall can house 400,000 to 1 million servers. These data centers are built on economies of scale, i.e. the larger the datacenter, the lower the operational cost. The network cost to operate a small data center is about 7 times greater and storage costs about 5.7 times greater than the costs to operate a large data center. Most datacenters are built with commercial off the shelf (COTS) components. A COTS server consists of a number of processor sockets, each with a multicore CPU and its internal cache hierarchy, local and shared DRAM, and a number of directly attached disk drives (DASD). The DRAM and the DASD within the rack are accessible through first-level rack switches and all resources in all racks are accessible via a cluster-level switch.

Warehouse-Scale Data Center Building Blocks. Typical elements in warehouse-scale systems: 1 server (left), 7 rack with Ethernet switch (middle), and diagram of a small cluster with a cluster-level Ethernet switch/router (right).

Generally, intra rack connectivity is often cheaper than inter rack connectivity. Warehouse-Scale Data Center: Network Fabric Choosing a networking fabric for WSCs involves a trade-off between speed, scale, and cost.1-gbps Ethernet switches with up to 48 ports are essentially a commodity component, costing less than $30/Gbps per server to connect a single rack. However, network switches with high port counts, which are needed to tie together WSC clusters, have a much different price structure and are more than ten times more expensive (per 1-Gbps port) than commodity switches. As a result of this cost discontinuity, the networking fabric of WSCs is often organized as the two-level hierarchy depicted in the previous figure. For example, a rack with 40 servers, each with a 1-Gbps port, might have eight 1-Gbps uplinks to the cluster-level switch, corresponding to an oversubscription factor between 5 for communication across racks.

Warehouse-Scale Data Center: Storage Hierarchy. Figure shows a programmer s view of storage hierarchy of a typical WSC. A server consists of a number of processor sockets, each with a multicore CPU and its internal cache hierarchy, local and shared DRAM, and a number of directly attached disk drives. The DRAM and disk resources within the rack are accessible through the first-level rack switches (assuming some sort of remote procedure call API to them), and all resources in all racks are accessible via the cluster-level switch.

Warehouse-Scale Data Center: Cooling System.

Warehouse-Scale Data Center: Cooling System CRAC units (CRAC is a 1960s term for computer room air conditioning) pressurize the raised floor plenum by blowing cold air into the plenum. This cold air escapes from the plenum through perforated tiles that are placed in front of server racks and then flows through the servers, which expel warm air in the back. Racks are arranged in long aisles that alternate between cold aisles and hot aisles to avoid mixing hot and cold air. Eventually, the hot air produced by the servers re-circulates back to the intakes of the CRAC units that cool it and then exhaust the cool air into the raised floor plenum again. CRAC units consist of coils through which a liquid coolant is pumped; fans push air through these coils, thus cooling it. A set of redundant pumps circulate cold coolant to the CRACs and warm coolant back to a chiller or cooling tower, which expel the heat to the outside environment. Typically, the incoming coolant is at 12 14 C, and the air exits the CRACs at 16 20 C, leading to cold aisle (server intake) temperatures of 18 22 C.

Warehouse-Scale Data Center: Quantifying Latency, Bandwidth, and Capacity

Warehouse-Scale Data Center: Quantifying Latency, Bandwidth, and Capacity The next figure attempts to quantify the latency, bandwidth, and capacity characteristics of a WSC. We assume a system with 2,000 servers, each with 8 GB of DRAM and four 1-TB disk drives. Each group of 40 servers is connected through a 1-Gbps link to a rack-level switch that has an additional eight 1-Gbps ports used for connecting the rack to the cluster-level switch (an oversubscription factor of 5). The graph shows the relative latency, bandwidth, and capacity of each resource pool. For example, the bandwidth available from local disks is 200 MB/s, whereas the bandwidth from off-rack disks is just 25 MB/s via the shared rack uplinks. On the other hand, total disk storage in the cluster is almost ten million times larger than local DRAM. A large application that requires many more servers than can fit on a single rack must deal effectively with these large discrepancies in latency, bandwidth, and capacity.

. Container Data Center Design

The container-based facility has achieved extremely high energy efficiency ratings compared with typical datacenters today. E.g. Google s container based datacenter. Container Data Center Design Container-based datacenters go one step beyond in-rack cooling by placing the server racks into a standard shipping container and integrating heat exchange and power distribution into the container as well. Similar to full in-rack cooling, the container needs a supply of chilled water and uses coils to remove all heat from the air that flows over it. Air handling is similar to in-rack cooling and typically allows higher power densities than regular raised-floor datacenters. Thus, container-based datacenters provide all the functions of a typical datacenter room (racks, CRACs, cabling, lighting) in a small package. Like a regular datacenter room, they must be complemented by outside infrastructure such as chillers, generators, and UPS units to be fully functional.

Google Data Center (Video) https://www.youtube.com/watch?v=pbx7rgqegg8