DSX Master Communications



Similar documents
DSX-HSCS Hot Swap Comm Server

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Global Monitoring + Support

T3 Mux M13 Multiplexer

If you need additional assistance please contact our Technical Support Center at 24 hours a day, 7 days a week.

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

DSX-RMS1076 Redundant Monitoring System UL 1076 Installation Manual August 2009

Eaton Remote Monitoring Manual

Accessing Diagnostics using a Dialup Modem

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

EZ-View Network Communications Guide

NMEA 0183 INSTALLATION AND OPERATING GUIDELINES

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

NESS-APX. Training Manual

GV-Data Capture V3 Series User's Manual

Temperature & Humidity SMS Alert Controller

Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever.

Windows Pocket PC. 1. Verizon Wireless Mobile Office Kit; which contains a serial data cable for your mobile phone and a PDA adapter

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

SMC7004ABR Barricade Broadband Router Installation Instructions

EMBEDDED ACCESS CONTROL Hardware Installation Guide

NPort s Ethernet Modem Mode

Status Monitoring. Using Drivers by Seagull to Display Printer Status Information WHITE PAPER

Access control designed simply for you

DoorKing IM Server TM

Connecting the DG-102S VoIP Gateway to your network

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

Using IDENT M System T with Modbus/TCP

Windows Pocket PC 2002

CipherLab 5100 Time Attendance Utility Manual

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Modbus and ION Technology

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

Andover Continuum Remote Communication Configuration Guide

SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ

1. MOXA NPort Express TCP/IP to RS-232 server

Crow Limited Warranty. Print Version 017

The technical aspects of V90 or V92 on two analogue telephone lines (both side PSTN) or a so called a point to point connections.

DIAL-UP DATA. Troubleshooting

1 Serial RS232 to Ethernet Adapter Installation Guide

Aolynk DR814Q ADSL2+ Broadband Router Quick Start

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

LevelOne VOI H.323 VoIP Gatekeeper. User Manual

User manual Rev 1.3 Contents

RS232 Programming and Troubleshooting Guide for Turbo Controls

IP Indoor High Speed Dome. CAM-6500 series. Ver Quick Installation Guide

EQUIPMENT SPECIFICATIONS

Kepware Technologies Optimizing KEPServerEX V5 Projects

Part Number Revision A, January Monitoring System Rack Configuration and Utilities Guide

Metasys System Direct Connection and Dial-Up Connection Application Note

Using Xbee in Serial Communication

version 3.1. Security modem with USB port user guide

Monitoring solar PV output

Topaz. GE Security. Intelligent software for access control. Topaz. Features

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

T1 Networking Made Easy

PRILINK PRI Management System

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

INTRODUCTION FEATURES OF THE ICM

Knowledge Base POS/C31A Troubleshooting

Application/Connection Examples

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Features Phone Access Features Web Access emta Quick Reference Guide Troubleshooting Quick Reference Guide...

GE Security. FHSD Monitor / Web Server user manual

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

[Setup procedure for Windows 95/98/Me]

Application Note. Terminal Server G6

IP SERIAL DEVICE SERVER

EMG Ethernet Modbus Gateway User Manual

Follow these steps to prepare the module and evaluation board for testing.

CONNECTING PHONES, FAXS & DEVICES TO TALKSWITCH

FTP Automation Guide

Chapter 1 Connecting the Router to the Internet


PROPRIETARY INFORMATION NOTICE

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Revolution Web ShoreTel Innovation Network Application Note for ShoreTel 14.1

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

DeviceMaster UP Modbus Controller to Controller Communication

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

ENGLISH. Land Phone Line Remote Communication Station Usage Manual. Please read this manual carefully, before starting to operate the station.

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Plena Voice Alarm System Firmware update

isco Connecting Routers Back to Back Through the AUX P

EDI Distributor Control Interface Wiring and Setup Instructions

POS Integration. Prepared by: Binh Nguyen

Iridium Extreme TM Satellite Phone. Data Services Manual

Connecting and Setting Up Your Laptop Computer

Operating Instruction MEW01652 Revision -

Transcription:

DSX Access Systems, Inc. PC to Master Controller - Direct Connect Communications DSX Master Communications Communications between the Comm Server PC and the Master Controller can take several forms which we will discuss with great detail here. The most simple and basic of communication approaches is RS-232. This can be used with the DSX-1040 Series Controllers for short distances. The Serial Port of the Comm Server PC is directly connected to the Master Controller. This is done with a 2 pair 22AWG cable with an overall shield. This type of connection is good for up to 50 feet of distance between the PC and the Master Controller. A DSX-USB is also available to convert USB to RS-232. If more than 50 feet of distance is required from the PC to Master Controller two DSX-MCI modules must be used. The first one converts the RS-232 to RS-485 which is good for 4000 feet of distance using a 2 twisted pair 22AWG cable. The second DSX-MCI is used to convert the RS-485 back to RS-232 for the Master 1040 Series Controller. A DSX-USB could also be used with an MCI to gain the distance necessary.

The DSX-1022 Series Controller communicates using RS-485 only. This requires a DSX-MCI or USB module to convert the RS-232/USB port of the PC to RS-485 for the 1022 Series Master Controller. The module is placed at the PC and using a 2 twisted pair 22AWG cable the Master Controller can be up to 4000 feet away. Comm Server PC Serial Port RS-232 RS-485 1022 USB to PC RS-485 RS-232 To Master To Master DSX-MCI PC to Master Controller - TCP/IP Communications The DSX-LAN(M) module is typically used to connect a Master Controller to the Comm Server PC over a Local or Wide Area Network. The WinDSX software is inherently TCP/IP capable and can redirect communications that would normally be transmitted out a serial port, over a LAN/WAN to a particular IP address. The DSX-LAN(M) module receives that communication and converts it to RS-232 or RS-485 that connects directly to the Master Controller. The illustration below shows the Comm Server communicating with two Location Master Controllers. Data packets between the PC and the Master Controller vary in size. Bandwidth The majority of the packets between the Comm Server and the Location Master Controller are empty polls and are only 18 bytes long. The longest packet is 200 bytes long. A communications connection between the WinDSX Comm Server and a Location Master Controller uses approximately 4800 bits per second of bandwidth. Size of database is not relevant.

This next illustration shows that there are three types of communications that can be used to Location Master Controllers. All three methods can be used at the same time. There can be multiple Locations using each of the different methods; Direct, Dial-up, and LAN. When more serial ports are needed for connections to Location Master Controllers than what the PC has, a DIGI Board can be used. Below is a DIGI Board that can provide up to 64 serial ports for multiple Direct and Modem connected Locations.

PC to Master Controller Communications via Dial-Up Modems The WinDSX system is capable of communicating with many Locations via dial-up phone modems. Since the system is fully distributed and does not require a PC for operation, there is practically no loss of performance in systems using dial-up phone modems. All panels retain all capabilities including card access, antipassback, and I/O Linking. A DSX modem can be connected to the Comm Server and used to communicate with many Location Master Controllers that also have a DSX Modem. Below is an illustration showing one DSX Modem connected to a serial port communicating to another DSX Modem over a standard dial-up phone line. The second DSX Modem is connected directly to the DSX-1048 Master Controller. This one modem could be used to communicate with several Location Master Controllers like in the drawing below. This drawing also shows the 1022 Master Controller requires a DSX-MCI module between the Modem and the Master Controller. Additional Modem Operation Information The PC may be programmed to routinely poll each modem-controlled Location. Routine Polls include verification that communications are still functioning and the collection of history logs. If the PC fails to connect with a modem Location on three consecutive attempts, a Location Communications Loss alarm is generated at the PC. If the PC is not programmed to routinely poll the Location Master, the Master panel will automatically store all transactions until the history buffer reaches 80% of capacity. When the buffer is at 80%, the Master panel calls the PC to upload all transactions if the PC is programmed to do so. The default settings for these two values are to poll the dialup site as often as possible, and also to dial the PC when the Transaction Buffer reaches 80% capacity. If an alarm event occurs, the Master will initiate a call to the PC to report the alarm event regardless of its buffer status. If the Master panel is reset for any reason, it will automatically call the PC and request a full parameter download to ensure proper operation. DSX recommends the DSX series modems for dial up phone modem communications. This series of modems are small dial up phone modems that may be powered from the battery backed up 12VDC power of the DSX control panel. By powering the modem from the panel, the modem is battery backed up so that communications will occur even during an AC power loss. An external DC power transformer is supplied with each DSX modem shipped. The wire that connects the power cube to a modem can be removed and used to attach the backed up power source from the panel to the modem. DSX configures and initializes all modems before shipping. They are shipped with everything necessary for installation. These are the only modems DSX will support. Other modems may or may not work properly. If it s not a DSX modem you are basically on your own!!!

Phone Call Description During an incoming call at the PC, the modem transmits a ring signal to indicate that the line is ringing. The Software then commands the modem to go Off Hook. The two modems form a link by transmitting a carrier tone through the phone line. At this time, the modem will turn on the Carrier Detect (CD) light. Communication will then proceed between the Master and the PC at the defined baud rate. The PC is always responsible for dropping the connection (hanging up the phone). The Master's modem hangs up when the connection is dropped. The PC modem must be initialized before it will function properly. Each time the communications program is started, and before each outbound call, the modem is automatically initialized. If the modem loses power, or is turned off and then back on, it must be re-initialized. To manually re-initialize the modem, do a manual connect and disconnect or leave the communications program and return.