PROPRIETARY INFORMATION NOTICE

Size: px
Start display at page:

Download "PROPRIETARY INFORMATION NOTICE"

Transcription

1 2012 LX I Technologies, Inc. Engineering Department [LEASED LINE MODEM LXV92] This document will cover the operations and installation on the LXV92 92 lease line modem. This modem is designed to work with most LX Technologies software.

2 PUBLICATION INFORMATION Title Date Action Draft 1/2012 Initial release 1/2012 1st Edition While this information is presented in good faith and believed to be accurate, LX Technologies, Inc. disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers. SpectrumLX, SafeCryptNet, and QuickPic are all trademarks of LX Technologies, Inc. All rights reserved. Windows 7 and Windows XP are registered trademarks of Microsoft Corporation. Linux is a registered trademark of Linus Torvalds. Other brand or product names are trademarks of their respective owners. PROPRIETARY INFORMATION NOTICE THIS MANUAL CONTAINS PROPRIETARY INFORMATION THAT IS THE PROPERTY OF LX TECHNOLOGIES, INC. THIS MANUAL IS FURNISHED TO THE AUTHORIZED USERS, DEALERS, AND/OR DISTRIBUTORS SOLEY TO FACILITATE THE USE OF SUCH PROGRAMS AS SPECIFIED IN WRITTEN AGREEMENTS, AND EXCEPT AS PROVIDED IN SUCH WRITTEN AGREEMENTS SHALL NOT BE REPRODUCED, COPIED OR USED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN PERMISSION OF LX TECHNOLOGIES, INC..

3 [LEASED LINE MODEM LXV92] January 21, 2012 Thank you for purchasing the LX Technologies LXV92 Leased Line Modular Modem. We are committed to providing quality products like the module modem. This document outlines the installation and setup of the LXV92 to enable communication between the upper and lower panels (specifically the IAD IAD-4514 and ICD-810 panels) via a 2-wire wire leased phone line. For additional configurations please contact support group at LX Technologies Inc.,, for specific details. LED indicators Power switch and power connection 25 pin / RS-232 connection Speaker Phone line connection

4 Features Serial interface (RS232 only) V.92-56kbps data Data rate 300bps to 33.6kbps DTMF recognition and decoding Extended temperature range operation (operates between -40 Celsius to +85 Celsius) Asynchronous/Synchronous operation Full-duplex speakerphone function Modular supported V92 and V90 Bell 202 compatible Meets CTR21 specification Flash upgradable firmware 2 wire leased line with auto- negotiation Voice playback and record capabilities Microphone input for voice applications Onboard NVRAM for storing settings 25 Celsius Parameter Minimum maximum units Tip/Ring current ma continuous Dialectic withstanding V rms voltage Operating temperature Celsius Relative Humanity % Voltage requirements V Transmission and -10(tx) -43(rx) dbm receive level Power consumptionlow-power sleep mode Typical 157ma Typical 26ma ma

5 This modem is capable of additional features, but we will cover the lease line options only, for more information regarding other options please contact LX Technologies, Inc. for further documentation. BOARD LAYOUT AND PIN CONNECTION LED indicators Figure 0-1 Block diagram PWD - Power Indicator DTR - TXD - RXD - Data Terminal Ready Transmit Data Receive Data CTS/OH Clear to Send CD - RI - DSR - Carrier Detect Ring Indicator Data Set Ready

6 RS Pin Connector

7 Jumper The modular modem has three 2 pin headers or jumpers to put the modem into the two wire leased line mode. Those jumpers have no affect for normal dial-up modem operations and should only be moved to put the modem into leased line mode. To set the modem to the leased line mode utilize the following settings: JP1 ON for both modems Originate mode JP2 ON, JP3 OFF Answer mode JP2 OFF, JP3 ON Phone Line Connector Tip and Ring The two pins required for connecting to the phone line or leased line. RJ11 wiring 6P6C connector showing the location of pin 1 Cables sold as RJ11 often actually use 6P4C RJ14 connectors (six position, four conductor), with four wires running to a central junction box. Two of its six possible contact positions connect tip and ring, and the other two conductors are then unused. 6P2C and 6P6C can also be found in stores.

8 The conductors other than the two central tip and ring conductors are used for various things such as a ground for selective ringers, low voltage power for a dial light, or for 'anti-tinkle' tinkle' circuitry to prevent pulse dialing phones from ringing the bell on other extensions. With tone dialing, anti-tinkle tinkle measures are not required. PIN CONNECTOR [LEASED LINE MODEM LXV92] January 21, 2012 Holding the connector in your hand tab side down with the cable opening toward you, the pins are numbered 1 6, left to right. Position Pair T/R ± RJ11 RJ14 RJ25 Twisted pair colors 25-pair colors Old colors German colors Australian colors 1 3 T + T3 white/green white/green white pink orange 2 2 T + T2 T2 white/orange white/orange black green red 3 1 R - R1 R1 R1 blue blue/white red white blue 4 1 T + T1 T1 T1 white/blue white/blue green brown white 5 2 R - R2 R2 orange orange/white yellow yellow black 6 3 R - R3 green green/white blue gray green Power connector LXV Standard connector 9V DC (AC transformer wall plug) LXV Custom connector 5V DC (Applying greater than 5.2 V DC will damage the modem and void the warranty)

9 MODE OF OPERATION- AT COMMAND SET Modems are used to originate or answer telephone calls and establish links with other modems for the purpose of transmitting data between two locations. Note: Jumpers, J1, J2, and J3 need to be removed while entering the AT command set. After you have completed the hardware connection, you will now be able to communicate with the modem and establish connections with remote devices. Controlling the modem functions is accomplished by using AT commands. Those commands are used to instruct the modem to perform functions such as dialing or answer a call. These commands are normally automatically issued by the communications software however with some applications (leased line modems) you will need to configure the modems through a terminal emulator to store your commands. The modem automatically accepts and processes AT commands on most standard DTE (data terminal equipment) speeds and parity settings. For each command issued, the modem will respond with a result code informing you of the modem status. The format of the basic AT commands and result codes are as follows: Command>> AT <command> <CR> Result>> OK or ERROR AT = Attention what follow is a command <Command> = a valid command <CR> = carriages return or enter key OK = result code meaning: the modem has accepted the command ERROR = result code meaning: the modem has not accepted the command Following codes are a subset of AT commands set, to get you up and operational utilizing the leased line option: Command ATM<0> ATM<1> ATM<2> ATM<3> ATL<0> ATL<1> Description Speaker is always off Figure is on during call establish but goes off when carrier is detected(default) Speaker is always on Speaker is off during dialing and receiving the carrier but on during answering Off or low volume Low volume(default)

10 ATL<2> Medium volume ATL<3> High volume AT&F Reset set modem to default AT&W&W1 Save current configuration AT+MS AT+MS Select / force modulation- this command is useful if you are required to limit the modem to a specific modulation or line speed Example AT+MS=V32,0,9600,9600<CR> This will force the modem to connect at 9600 baud for transmit and receive. This is a good starting point to connect your lease line modems. Syntax: AT+MS=<carrier>,<auto mode>,<min_tx_rate>,<max_tx_rate> As a minimum command set, enter the red-lighted commands to set up your modems for lease line. Jumpers, J1, J2, and J3 need to be removed while entering the data. After the commands have been successfully entered then set up your jumpers for originate and answer modems. The orange -lighted commands maybe required based on the grade of the phone line. After you have changed your settings and set the jumpers, re-power your modems. After a 5 second delay they will begin to negotiate and connect at the appropriate speeds. Once the modems have connected, you should have the CD led illuminated. Modulation Control Commands +MS - Modulation Selection This extended-format compound parameter controls the manner of operation of the modulation capabilities in the modem. It accepts six sub parameters. Syntax +MS=[<carrier>[,<automode>[,<min_tx_rate>[,<max_tx_rate>[,<min_rx_rate> [,<max_rx_rate>]]]]]] Where possible <carrier>, <min_tx_rate>, <max_tx_rate>, <min_rx_rate>, and <max_rx_rate> values are listed below; Modulation <carrier> Possible (<min_rx_rate>, <min_rx_rate>, (<min_tx_rate>), Bell 103 B Bell 212 B Rx/75 Tx or 75 Rx/1200 Tx V.21 V21 300

11 [LEASED LINE MODEM LXV92] January 21, 2012 V.22 V.22 bis V.23 V.32 V.32 V.34 V22 V22B V23C V32 V32 V34 V.90 V90 V.92 downstream V92 V.92 upstream V or or or , 31200, 28800, 26400, 24000, 21600, 19200, 16800, 56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667, 56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667, 48000, 46667, 45333, 44000, 42667, 41333, 40000, 38667, IAD-4514 connected ed to an ICD-810 IAD-4514 RS232 LXV92 Phone Line RS232 RS232/RS485 Converter RS485 ICD-810

12 The RS232/RS485 converter shown above can be purchased separately from LX technologies. If purchased from another vendor the converter needs to support 2 wires RS485. RS422 converters will not work adequately. Compliance The LXV92 is certified with FCC part 68 and Canada DOC (IC) CS-03 rules. FCC part 68 This modem is FCC Part 68 Certified. FCC part 15 This modem is FCC part 15 Compliant. EMI/RFI emissions are rated at 3KV protection on the tip and ring to chassis ground. Industry Canada CS-03 - This modem is Canada CS-03 certified CTR21 statement: This equipment has been approved to [Council Decision 98/482/EC- CTR 21 ] for pan-european single terminal connection to the public switched telephone network (PSTN). However, due to variances between the individual PSTN s provided in different countries, an unconditional assurance of successful operation on every PSTN termination point cannot be provided. In the event of a problem, you should contact your equipment supplier. The Federal Communications Commission (FCC) has established rules, which permits this device to be directly connected to the telephone network. If this device is malfunctioning, it may also be causing harm to the telephone network; this device should be disconnected until the source of the problem can be determined and until repair has been made. If this is not done, the telephone company may temporary disconnect service. The telephone company may make changes in its technical operations and procedures; if such changes affect the compatibility or use of this device, the telephone company is required to give adequate notice of the changes. If the telephone company requests information on what equipment is connected to their lines, inform them of the following. The telephone number and the device it connected to. The ringer equivalence number (REN). The device uses and RJ 11 type jack. The FCC Registration number. The REN (ringer Equivalence Number) is used to determine the number of devices that may be connected to the telephone line. Excessive REN s on the telephone line may result in devices not ringing in response to an incoming call. In most, but not all areas, the sum of the REN should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total REN s, contact the local telephone company. The telephone consumer protection act of 1991 makes it unlawful for any person to use a computer or any other electronic device, including fax machines, to send any message unless such message clearly contains in a margin at the top or bottom of each transmission page or on the first page of the transmission, the date and the time, it is sent and an identifier of the business or other entity, or other individual sending the message and the telephone number of the sending machine or such business, other entity, or individual. (The telephone number provided may not be a 900 number or any number of which changes exceed local or long-distance transmission charges.) State tariffs. Contact state public utility commissions for information. In order to program this information into your fax machinefor fax/ modem, consult your fax machine user s manual for setup instructions.

13 Glossary Baud - Bytes per second. When a computer file command, document, or other format is transmitted over a line, it must be broken down into packets (segments) of information. Baud is the measure of the transmission speed of those packets. Transmission speeds typically range from 2400 baud to 56K (thousand) baud, (but can exceed those parameters depending on the type of transmission line or medium used). Byte - Eight (or seven, sometimes) bits make up one byte. A byte contains information, which the computer can recognize and process according to a program s operating parameters. A word processing program, for example, recognizes the one byte of information that is transmitted from the keyboard to the CPU when the "A key is clicked, and displays an A on the screen in accordance with its operating parameters. Data transmission speeds are typically measured in bytes per second, meaning the number of bytes which can be processed and sent depending on hardware and software limitations, (modem speed, transmission medium, line type, etc.) FIFO - First in, first out, a description of a type of buffer. Buffers can only hold so much information before they are full. Some are like buckets, where, when they become full, retain the information that is already contained in the buffer, and disregard any additional information. Some buffers are like pipelines, where information goes into the buffer in one end, and, as more information is added, the latest information is retained, and the oldest is pushed out the other end, either to storage on a disk, for instance, or printed on a printer, or even simply disregarded. Firmware - Firmware is changeable programming information housed on (or in) semipermanent hardware, like CPU chips. While hardware is generally unchangeable, and software is generally wholly changeable, firmware provides a measure of security by storing the changeable programming information on a hard-to-change medium electrical circuit board, ready to perform its functions until being re-programmed. (See also hardware and software.) Half-Duplex - Half-Duplex is a description of communications between two entities which use the same lines or media for transmission and receiving. In the illustration below, an ICD-810 uses half duplex (2-wire) communication to send and receive command instructions and event messages with an IAD-4514 Hardware - The unchanging computer equipment, printers, hardware panels, and other devices in a computer system. Hardware is generally unchangeable in that users cannot, for example, easily modify it to make it work in anything other than its original set parameters. (See also firmware and software.)

14 LED - Light Emitting Diode. Hardware panels and devices often feature red, green, or yellow LED s which allow security operators to visually verify the operational status of the equipment. LED s emit a glowing light, which is a visual cue to system operating status. Networking - Networking is the connection of computer servers, workstations, hardware panels, printers, and other assets to allow for file sharing, system-wide updates, and efficient communication between users. Local Area Networks (LAN s) generally cover a building or small geographic area, and Wide Area Networks (WAN s) generally cover a larger geographic area or several widely scattered buildings. Port - A generic term for an input/output connection on a computer board. A port for serial communications, for example, would accept an appropriate cable to allow a serial device to be connected to the computer. RS A type of communication module which is fitted to hardware devices to allow them to communicate with a controlling computer or other hardware panel. The RS-232 standard allows serial communication along a line from one controlling device to one receiving device. (See serial.) RS-232 communications are limited to 50 feet (about 15 meters) between controlling to receiving hardware, (without line extenders). RS A type of communication module which is fitted to hardware devices to allow them to communicate with a controlling computer or other hardware panel. The RS-485 standard, unlike the RS-232 standard, allows multiple receiving devices to communicate with a single controlling device, using one line, (known as multiple drops or points where receiving hardware can be attached to the single line). The RS-485 communication standard allows the communication line to be 4,000 feet long, (without line extenders). Serial - Serial communications, as compared to parallel communications, allow communications in one direction at any given time over a single communication line. For example, Device A communicating via serial standard to Device B would only be allowed to send to Device B when it was not receiving along the single communication line. Parallel communication, on the other hand, allows simultaneous sending and receiving along a single communication line. Serial Port - A hardware connection on a computer board which accepts a serial cable plug-in, and allows serial communications between the computer and associated hardware devices, (like a printer, for example).

15 Contact information LX Technologies, Inc W. Peoria Ave # Phoenix, AZ (602) 870-4LXT (602) FAX

Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)

Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount) Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION

More information

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A User Manual + - CD CTS RTS DTR. DSR RI RX TX PHONE LINE DLM Dial-Up / Leased-Line Modem Dial-Up / Leased-Line Modem CONTENTS

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

RS-232/422/485, Power over Ethernet

RS-232/422/485, Power over Ethernet IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware

More information

IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A

IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A IPG/7700 Hardware Manual SYSTECH C O R P O R A T I O N Document number 80-001099-7 Revision A Created 2010, and Protected Under the U.S. Copyright Act of 1976. Copyright 2010, SYSTECH Corporation All Rights

More information

Date Rev. Details Author

Date Rev. Details Author Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY

More information

VOICE RECORDING SYSTEM ISDN PRI / BRI

VOICE RECORDING SYSTEM ISDN PRI / BRI Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE

More information

How To Set Up A 366101 Modem (Marc) Model 366101 (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

How To Set Up A 366101 Modem (Marc) Model 366101 (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar DIN Rail Mounted Leased Line Modem Users Manual 366-101 Rev. 2 Copyright 2008 Miille Applied Research Co., Inc. Houston, Texas This page is left blank intentionally Page i TABLE OF CONTENTS LIST OF FIGURES...

More information

User Manual IC-485AI 2002-09-27

User Manual IC-485AI 2002-09-27 User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable

More information

Bluetooth to Serial Adapter

Bluetooth to Serial Adapter Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin

More information

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.11 September 13, 2006 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998,

More information

1-Port R422/485 Serial PCIe Card

1-Port R422/485 Serial PCIe Card 1-Port R422/485 Serial PCIe Card Installation Guide 1. Introduction Thank you for purchasing this 1-Port RS422/485 Serial PCI Express (PCIe) Card. It is a universal add in card that connects to a PC or

More information

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.

More information

U.S. Robotics Modems: User s Guide

U.S. Robotics Modems: User s Guide U.S. Robotics Modems: User s Guide http://www.usr.com/ Published September 2000 U.S. Robotics Corporation 3800 Golf Rd. Rolling Meadows, IL 60008 Copyright 2000 U.S. Robotics Corporation. All rights reserved.

More information

DSX Master Communications

DSX Master Communications DSX Access Systems, Inc. PC to Master Controller - Direct Connect Communications DSX Master Communications Communications between the Comm Server PC and the Master Controller can take several forms which

More information

AXIS 5810 A Bluetooth Print Plug. Quick Start

AXIS 5810 A Bluetooth Print Plug. Quick Start AXIS 5810 AXIS 5810 A Bluetooth Print Plug Quick Start BLUETOOTH is a trademark owned by its proprietor and used by Axis Communications AB under license 1 AXIS 5810 Regulatory Information Regulatory Information

More information

Comtrol Cable User Guide

Comtrol Cable User Guide Comtrol Cable User Guide Trademark Notices Comtrol and DeviceMaster are trademarks of Comtrol Corporation. PortVision is a registered trademark of Comtrol Corporation. Microsoft and Windows are registered

More information

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed

More information

Keep it Simple Timing

Keep it Simple Timing Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring

More information

USB TO SERIAL ADAPTER

USB TO SERIAL ADAPTER USB TO SERIAL ADAPTER (Model: U232-P9V2) SPECIFICATIONS CONTENTS 1. GENERAL SPECIFICATIONS... 1 1.1 PRODUCT SURFACE... 1 1.2 PRODUCT DIMENSION... 2 1.3 PRODUCT FEATURES... 3 1.4 PRODUCT SPECIFICATIONS...

More information

One Port Serial Server Users Manual Model ESP901, ESP901E

One Port Serial Server Users Manual Model ESP901, ESP901E One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350

More information

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone 12-36-1000 Autodialler and Relay Telephone Interface 1.0 INTRODUCTION 12-36-1000 I/O Telephone Interface with AutoDialer The 12-36-1000 is a autodialer and telephone interface that can be used autonomously

More information

USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854

USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854 USB-to-Serial RS-232 Hub USB-to-Serial RS-422/485 Hub USER MANUAL UC2322 / UC2324 / UC4852 / UC4854 FCC Information This equipment has been tested and found to comply with the limits for a Class B digital

More information

XPort Universal Demo Board User Guide

XPort Universal Demo Board User Guide XPort Universal Demo Board User Guide Part Number 900-563 Revision A September 2009 Copyright and Trademark Contacts 2009 Lantronix. All rights reserved. No part of the contents of this book may be transmitted

More information

Software User Guide UG-461

Software User Guide UG-461 Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment

More information

PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999

PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been

More information

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R- MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features

More information

Cable Connection Procedures for Cisco 1900 Series Routers

Cable Connection Procedures for Cisco 1900 Series Routers CHAPTER 5 Cable Connection Procedures for Cisco 1900 Series Routers This document describes how to connect your Cisco 1941 integrated services router to a power source and to networks and external devices.

More information

Modbus Communications for PanelView Terminals

Modbus Communications for PanelView Terminals User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document

More information

KVM - DVI, USB 2.0, Cat 5 Extender

KVM - DVI, USB 2.0, Cat 5 Extender KVM - DVI, USB 2.0, Cat 5 Extender 330 feet (100 meters) EL5100 User Guide Powered by Thank you for purchasing the KVM - DVI, USB 2.0, Cat 5 Extender 330 feet (100 meters) Please read this guide thoroughly.

More information

Administrative Council for Terminal Attachments (ACTA) Customer Information

Administrative Council for Terminal Attachments (ACTA) Customer Information Administrative Council for Terminal Attachments (ACTA) Customer Information Revision: July 2003 Background: The Administrative Council for Terminal Attachments ( ACTA ) has revised its Customer Information

More information

MultiModem ZBA. Quick Start Guide. MT9234ZBA-Series MT9234ZBA MT9234ZBA-V

MultiModem ZBA. Quick Start Guide. MT9234ZBA-Series MT9234ZBA MT9234ZBA-V MultiModem ZBA MT9234ZBA-Series MT9234ZBA MT9234ZBA-V Quick Start Guide MultiModem ZBA Quick Start Guide MT9234ZBA & MT9234ZBA-V 82100201L Rev. B Copyright This publication may not be reproduced, in whole

More information

System Requirements. Hiro H50113

System Requirements. Hiro H50113 1 Hiro H50113 System Requirements Hiro H50113 Computer with Pentium 200 MMX or higher processor. Windows 2000, Windows XP Home / Professional, XP Professional x64 Edition, Vista 32 / 64 Families, Windows

More information

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D Tele Eye DT Series Dialup CCTV Transmitter DT-103G DT-103P DT-103D Installation Guide Notice: Signal Communications Limited reserves the right to make improvements to the product described in this manual

More information

T3 Mux M13 Multiplexer

T3 Mux M13 Multiplexer T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract

More information

APPLICATION NOTE. Leased Line Modem. Leased Line Modem...3. Introduction... 3. Key Concepts... 4

APPLICATION NOTE. Leased Line Modem. Leased Line Modem...3. Introduction... 3. Key Concepts... 4 Issue Date 02/18/02 APPLICATION NOTE Leased Line Modem Leased Line Modem...3 troduction... 3 Key Concepts... 4 Application Details...4 Theory of Operation...6 Components...8 Planning Considerations...10

More information

PHONE MANAGER INDEX. page

PHONE MANAGER INDEX. page PHONE MANAGER INDEX page 1 HARDWARE... 4 1.1 Requirements... 4 1.2 Indicators... 4 1.3 Hardware Configuration... 5 1.4 Hardware Installation... 5 2 SOFTWARE... 7 2.1 Software Installation... 7 2.2 Use

More information

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding

More information

GSM Interfacing Board

GSM Interfacing Board Campus Component Pvt. Ltd. DISCLAIMER Information furnished is believed to be accurate and reliable at the time of publication. However, Campus Component Pvt. Ltd. assumes no responsibility arising from

More information

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.

More information

USB to RS-422/485 Serial Adapter

USB to RS-422/485 Serial Adapter USB to RS-422/485 Serial Adapter User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2

More information

RS-232 COMMUNICATIONS

RS-232 COMMUNICATIONS Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

Single channel data transceiver module WIZ2-434

Single channel data transceiver module WIZ2-434 Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules

More information

RN-XV-RD2 Evaluation Board

RN-XV-RD2 Evaluation Board RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2

More information

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and

More information

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication

More information

DK40 Datasheet & Hardware manual Version 2

DK40 Datasheet & Hardware manual Version 2 DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...

More information

18.04.2005 version 3.1. Security modem with USB port user guide

18.04.2005 version 3.1. Security modem with USB port user guide 18.04.2005 version 3.1 Security modem with USB port user guide Introduction Congratulations on selecting the new SECURITY MODEM data transfer device. We designed this modem for special users who are involved

More information

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 1999-2007 by Laipac Technology, Inc. All rights reserved The Specifications and information regarding the products in this manual

More information

Using the Teridian 73M2901CE in 4-Wire and Leased Line Applications

Using the Teridian 73M2901CE in 4-Wire and Leased Line Applications A Maxim Integrated Products Brand 7M90CE V. bis Single Chip Modem APPLICATION NOTE AN_90CE_0 February 009 Introduction Using the Teridian 7M90CE in -Wire and Leased Line Applications The Teridian 7M90

More information

F2400 FOM II Series Fiber Optic Modem Technical Manual

F2400 FOM II Series Fiber Optic Modem Technical Manual F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data

More information

Manual Serial PCI Cards

Manual Serial PCI Cards Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make

More information

Serial over Ethernet Device Server. User s Manual

Serial over Ethernet Device Server. User s Manual Serial over Ethernet Device Server User s Manual Second Edition, November 2005 SUNIX Co., Ltd. Tel : +886-2-8913-1987 Fax: +886-2-8913-1986 Http://www.sunix.com.tw info@sunix.com.tw Serial over Ethernet

More information

Wireless Router Setup Manual

Wireless Router Setup Manual Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,

More information

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop

More information

RC2200DK Demonstration Kit User Manual

RC2200DK Demonstration Kit User Manual Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7

More information

Bluetooth HC-06 with serial port module Easy guide

Bluetooth HC-06 with serial port module Easy guide 1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550

More information

HOW TO USE YOUR INTELE-MODEM

HOW TO USE YOUR INTELE-MODEM HOW TO USE YOUR INTELE-MODEM 305-008800 Ultratec, Inc. 450 Science Drive Madison, WI 53711 (608) 238-5400 (Voice/TTY) Fax: (608) 238-3008 Email: service@ultratec.com www.ultratec.com First Edition October

More information

Zypcom Application Note

Zypcom Application Note Zypcom Application Note Product: Z34-SX, Z34-RX, Z34-SE, Z34-RE, Z32t-SX, Z32t-SE, Z32t-RX, Z32b-SX, Z32b-SE, Z32b-RE and Z32b-RX Application: Leased Line Operation with Synchronous Data Synchronous leased

More information

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION RS-422/485 PCI Card User Manual English No. 51200 (2 Port) No. 51202 (4 Port) No. 51204 (8 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION (Nov 2005) 1.0 Introduction

More information

LBNP16312. RS-232/485/422 serial device server. User manual

LBNP16312. RS-232/485/422 serial device server. User manual Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3

More information

Why you need to monitor serial communication?

Why you need to monitor serial communication? Why you need to monitor serial communication Background RS232/RS422 provides 2 data lines for each data channel. One is for transmitting data and the other for receiving. Because of these two separate

More information

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP! Installation Guide AXIS 2191 Audio Module Sight, Speech and Sound over IP! AXIS 2191 Installation Guide Page 1 of 7 The AXIS 2191 Audio Module The AXIS 2191 Audio Module is an add-on device that provides

More information

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide RS-422/485 Multiport Serial PCI Card Installation Guide 21 Contents 1. Introduction...1 2. Package Check List...2 3. Board Layouts and Connectors...3 3.1 2S with DB9 Male Connectors...3 3.1.1 JP5: UART

More information

Iridium Extreme TM Satellite Phone. Data Services Manual

Iridium Extreme TM Satellite Phone. Data Services Manual Iridium Extreme TM Satellite Phone Data Services Manual Table of Contents 1 OVERVIEW... 1 2 HOW IT WORKS... 1 3 BEFORE INSTALLING... 2 4 USB DRIVER INSTALLATION... 3 5 MODEM INSTALLATION AND CONFIGURATION...

More information

TD-8610/TD-8610B External ADSL2+ MODEM

TD-8610/TD-8610B External ADSL2+ MODEM TD-8610/TD-8610B External ADSL2+ MODEM Rev: 1.0.2 1910010011 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other

More information

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2) Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2) Legal notice: Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are

More information

2-Wire/4-Wire Telephone Line Interface. XE0204 Block Diagram

2-Wire/4-Wire Telephone Line Interface. XE0204 Block Diagram XE0204 July 2000 2-Wire/4-Wire Telephone Line Interface Description The XE0204 provides a common telephone interface for networks integrating two and four-wire telephone connections. The XE0204 supplies

More information

RIU-IP Remote IP Interface User Guide

RIU-IP Remote IP Interface User Guide RIU-IP Remote IP Interface User Guide JK Audio Introduction The RIU-IP is a remote control interface designed for use with the JK Audio innkeeper 1x/1rx, innkeeper 2 or innkeeper 4 digital hybrids. This

More information

APPLICATION. Using the PB-100 to Make Calls and Announcements From a Database. Using the PB-100 for All-Call Dialing

APPLICATION. Using the PB-100 to Make Calls and Announcements From a Database. Using the PB-100 for All-Call Dialing APPLICATION Note TELECOM SOLUTIONS FOR THE 21ST CENTURY Using the PB-100 for All-Call Dialing March 22, 2002 Features Compatible with Windows 95, 98, ME, NT 4.0, 2000 Male sub-d 9 pin cable provided 20

More information

The technical aspects of V90 or V92 on two analogue telephone lines (both side PSTN) or a so called a point to point connections.

The technical aspects of V90 or V92 on two analogue telephone lines (both side PSTN) or a so called a point to point connections. The technical aspects of V90 or V92 on two analogue telephone lines (both side PSTN) or a so called a point to point connections. Even if this is a leased line connection or dial up connection the maximum

More information

Making a DB to RJ45 adapter.

Making a DB to RJ45 adapter. Making a DB to RJ45 adapter. DB9 to RJ45 adapters are often used in combination with a RS232 repeater for extending the distance of a serial RS232 link, but can be used for any adapter or converter purposes.

More information

GV-Keyboard. User's Manual V2.0

GV-Keyboard. User's Manual V2.0 GV-Keyboard User's Manual V2.0 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2007 GeoVision, Inc. All rights reserved.

More information

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:

More information

Accessing Diagnostics using a Dialup Modem

Accessing Diagnostics using a Dialup Modem Purpose This application note is meant to guide a user through the setup and use of a dial-up modem to retrieve diagnostics data from a remote master. Equipment Used This application note was written specifically

More information

MODBUS TCP to RTU/ASCII Gateway. User s Manual

MODBUS TCP to RTU/ASCII Gateway. User s Manual MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...

More information

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

5-port 10/100Base-TX Industrial Switch (314500) User s Guide 5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

More information

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear. SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between

More information

VSCOM USB PRO Series Industrial I/O Adapters

VSCOM USB PRO Series Industrial I/O Adapters VSCOM USB PRO Series Industrial I/O Adapters 1.Introduction The VSCOM USB PRO Series Industrial I/O Adapters are advanced USB to Serial Adapters that connect to 1, 2, 4 or 8 RS-232/422/485 serial devices.

More information

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as

More information

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series First Edition, March 2005 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 5 Block Diagram 6 Features 7 Product Specifications

More information

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming Somfy Digital Network (SDN) Installation and Programming SSoomffyy SSyysst teemss IInncc.. 1 Table of Contents 1 General Information and Features... 3 1.1 ILT2 Motor... 3 1.2 SDN Switches... 4 1.3 ILT2

More information

Linksys Gateway SPA2100-SU Manual

Linksys Gateway SPA2100-SU Manual Linksys Gateway SPA2100-SU Manual Manuel de l'utilisateur Table of Contents Looking for Basic Setup Instructions?... 3 Most Recent Version of this Manual... 3 Advanced Setup Instructions... 4 Wiring Your

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents

More information

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE September 2004 Prepared by: Integrated Systems Division The Sutron Corporation 21300 Ridgetop Circle Sterling, VA 20166 Copyright 2004

More information

INSTALLATION / OPERATION MANUAL API-8/232

INSTALLATION / OPERATION MANUAL API-8/232 INSTALLATION / OPERATION MANUAL API-8/232 MONITOR TECHNOLOGIES INC. Installation of this product in accordance with this manual, applicable codes, and the instructions of the Authority Having Jurisdiction

More information

Teleservice via RS232 interface XC100/XC200

Teleservice via RS232 interface XC100/XC200 User Manual 10/10 MN0500005Z-EN replaces 07/04 AWB74-1490GB Teleservice via RS interface XC100/XC00 All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency

More information

OnQ 2x10 KSU/PBX Telephone System P/N 364565-01. User s Guide P/N 1307724 Rev. A

OnQ 2x10 KSU/PBX Telephone System P/N 364565-01. User s Guide P/N 1307724 Rev. A OnQ 2x10 KSU/PBX Telephone System P/N 364565-01 User s Guide P/N 1307724 Rev. A For information regarding any of the products discussed in this user s guide, contact your local OnQ product installer or

More information

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...

More information

2-Port RS232/422/485 Combo Serial PCI Card

2-Port RS232/422/485 Combo Serial PCI Card 2-Port RS232/422/485 Combo Serial PCI Card Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial PCI Card. It is a universal add in card that connects to a

More information

NT1 Type 400. NT1 Type 400 Standalone 1212016L1 NT1 Type 400 Circuit Pack 1212010 USER MANUAL

NT1 Type 400. NT1 Type 400 Standalone 1212016L1 NT1 Type 400 Circuit Pack 1212010 USER MANUAL NT1 Type 400 NT1 Type 400 Standalone 1212016L1 NT1 Type 400 Circuit Pack 1212010 USER MANUAL 61212016L1-1B January 1999 This device complies with Part 15 of the FCC rules. Operation is subject to the following

More information

Omron I/O Driver (Series 2) Programmable Serial Interface Card

Omron I/O Driver (Series 2) Programmable Serial Interface Card Omron I/O Driver (Series 2) Programmable Serial Interface Card USER MANUAL Rev. P1.55 June 8, 2012 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998, 1999.

More information

How To Connect A Port Replicator With An Ethernet To A Usb Port From A Usb Device

How To Connect A Port Replicator With An Ethernet To A Usb Port From A Usb Device USB Mobile Port Replicator with Ethernet NOTEBOOK COMPUTER MOBILE PORT REPLICATOR User s Guide INTRODUCTION Congratulations on your purchase of the Targus USB Mobile Port Replicator with Ethernet! It is

More information

Bluetooth Serial Adapter

Bluetooth Serial Adapter RN-BT-SRL-UM Bluetooth Serial Adapter 0 Roving Networks. All rights reserved. RN-BT-SRL-UM-.0 Version.0 //0 USER MANUAL RN-BT-SRL-UM-.0 OVERVIEW Roving Networks offers a variety of Bluetooth serial adapters

More information