Application Note. Terminal Server G6
|
|
|
- Jonathan Jones
- 9 years ago
- Views:
Transcription
1 MICROSENS GmbH & Co. KG Küferstr Hamm/Germany Tel FAX Web
2 Summary As of firmware version v10.6 MICROSENS Generation 6 (G6) switches will comprise of an internal terminal server functionality. This feature expands G6 switches with the ability to integrate single serial devices into LAN infrastructures. With a G6 switch operating in server, client or virtual COM port mode it is possible to realize a wide variety of applications for converting LAN communication into serial data communication and vice versa. This application note illustrates the configuration of MICROSENS switches as terminal server with documented examples
3 Table of Contents SUMMARY... 2 TABLE OF CONTENTS INTRODUCTION Operation Modes Connector Pinouts SERVER MODE Scenario Configuration Web Manager CLI Commands CLIENT MODE Scenario Configuration Web Manager CLI Commands COM PORT MODE Scenario Configuration Web Manager CLI Commands COM Port Driver CONFIGURATION OF PUTTY DISCLAIMER Graphical Conventions Graphical Element Explanation Work step(s) in the Web Manager (GUI) Work step(s) in the Command Line Interface (CLI) - 3 -
4 1 Introduction A terminal server basically works as a converter for conveying data from the switches serial port (RS-232 standard) to its LAN port (using the Telnet protocol, RFC 854) and vice versa. Thus it is possible to integrate serial devices (like scanners, printers, sensors etc.) into LAN infrastructures. For this reason this functionality is called "device server" as well. 1.1 Operation Modes There are three operation modes possible: Server mode: For transferring data from a LAN participant (e. g. a PC) to a serial port device (e. g. a printer with RS-232 port) the switch operates in server mode. Besides, this mode is used for accessing a serial device with a console line interface over LAN (e. g. with PuTTY on a PC). Client mode: For tunneling data from a serial port device to another over LAN one switch has to operate in server mode, the remote switch has to operate in client mode. COM port emulation mode: In special environments it could be necessary to emulate a serial port on a physical IP port of a serial tunneling partner (i. e. for lack of a physical serial port). To process those special serial data packets wrapped in IP packets the MICROSENS switch has to operate in COM port mode. For every serial device to be attached to the LAN a respective switch is needed. For a switch it is not possible to connect more than one serial device directly to its serial port. 1.2 Connector Pinouts Depending on the MICROSENS Switch model the serial port is accessible through a mini- USB connector (i. e. MICROSENS G6 Micro Switch) or an RJ-45 connector (i. e. MICROSENS G6 Industrial Switch). To connect a serial device directly to the serial port of the respective switch it is necessary to use a RS-232 null-modem interface or a cable with cross-over pinout. G6 Micro Switch (microusb) G6 Industrial Switch (RJ-45) Pin Signal Pin Signal 1 n.n. 1 n.n. 2 TXD 2 DC+ 3 RXD 3 TXD 4 DC+ 4 GND 5 GND 5 GND 6 RXD 7 n.n. 8 n.n. Table 1: Connector Pinouts - 4 -
5 2 Server Mode 2.1 Scenario For accessing a serial device (e. g. printer, controller etc.) over LAN using a TCP/IP socket application the serial device has to be connected directly to the switches serial port over a null modem connection (i. e. cross over cable). Configured as device server in server mode the switch listens to incoming serial communication data on its Ethernet port and transmits it to its serial port. After the connection is established both the serial device and the PC can exchange further serial data. 2.2 Configuration Figure 1: Server Mode Scenario Web Manager Take the following steps to configure the switch for server mode using the Web Manager: Open the Web Manager. Select the System screen, then select the tab Reboot & System. In the section System Configuration select the entry "Terminal Server" in the drop-down list for Serial Port to activate the terminal server. Changing the mode from terminal server to any other value during serial operation will stop the terminal server. Select the Misc screen, then select the tab Terminal Server. For Mode select "Server" from the drop-down list. For TCP Port enter the respective port. The default value is "1000". This port number has to correspondent to the respective application setting on the LAN device (i. e. PuTTY). For Data Rate select the respective rate from the drop-down list. Please refer to the serial devices documentation to determine its baud rate
6 2.2.2 CLI Commands Take the following steps to configure the switch for server mode using the command line interface: Enable the switches serial port for terminal server use: Device.System.serial_port = TERMINAL_SERVER Changing the mode from terminal server to any other value during serial operation will stop the terminal server. For configuring the terminal server parameters change to path Management.Misc.terminal_server_config Configure the parameters as follows: Management.Misc.terminal_server_config.mode = SERVER Management.Misc.terminal_server_config.tcp_port = <serial device TCP port> The default value is "1000". This port number has to correspondent to the respective application setting on the LAN device (i. e. PuTTY). Management.Misc.terminal_server_config.data_rate = <serial device baud rate> Please refer to the serial devices documentation to determine its baud rate. For more information about configuring all serial parameters with CLI please refer to the "MICROSENS Product Manual FW G6", chapter "Misc Function" available from the Web Manager. Now it is possible to access the serial device with every TCP based client like Telnet or Rlogin (command line) or PuTTY (GUI based). For more information about configuring PuTTY for connecting the switch refer to section
7 3 Client Mode 3.1 Scenario For connecting two serial devices over LAN one switch has to be configured in server mode while another switch has to be configured in client mode. Both switches communicate over LAN with each other. Because the serial devices seem to communicate over LAN this concept is called "serial tunneling" as well. Figure 2: Client Mode Scenario 3.2 Configuration For configuring the server mode please refer to the server mode example in section Web Manager Take the following steps to configure the switch for client mode using the Web Manager: Open the Web Manager. Select the System screen, then select the tab Reboot & System. In the section System Configuration select the entry "Terminal Server" in the drop-down list for Serial Port to activate the terminal server. Changing the mode from terminal server to any other value during serial operation will stop the terminal server. Select the Misc screen, then select the tab Terminal Server. For Mode select "Client" from the drop-down list. For Remote IP of the associated remote partner enter the respective IP address. For Data Rate select the respective rate from the drop-down list. Please refer to the serial devices documentation to determine its baud rate
8 3.2.2 CLI Commands Take the following steps to configure the switch for client mode using the command line interface: Enable the switches serial port for terminal server use: Device.System.serial_port = TERMINAL_SERVER Changing the mode from terminal server to any other value during serial operation will stop the terminal server. For configuring the terminal server parameters change to path Management.Misc.terminal_server_config Configure the parameters as follows: Management.Misc.terminal_server_config.mode = CLIENT Management.Misc.terminal_server_config.remote_ip = <IP address of switch working in server mode> Management.Misc.terminal_server_config.data_rate = <serial device baud rate> Please refer to the serial devices documentation to determine its baud rate. For more information about configuring all serial parameters with CLI please refer to the "MICROSENS Product Manual FW G6", chapter "Misc Function" available from the Web Manager. Now it is possible to access the serial device with every TCP based client like Telnet or Rlogin (command line) or PuTTY (GUI based). For more information about configuring PuTTY for connecting the switch refer to section
9 4 COM Port Mode 4.1 Scenario If a serial tunneling partner doesn't have a physical serial interface (e. g. an application in need of a serial port used on a modern PC), it is possible to emulate a virtual serial port on an IP port on this device. A special COM port driver maps the IP port of the PC to a virtual COM port emulating a serial connection. The driver envelops the serial data into IP packets and sends them through the devices physical IP interface. To cope with these IP packets by unpacking and forwarding the inside serial data packets to the serial port the switch has to operate in COM port mode. In COM port mode the switch acts as TCP client because most COM port emulators run a TCP server. 4.2 Configuration Figure 3: COM Port Mode Scenario Web Manager Take the following steps to configure the switch for COM port mode using the Web Manager: Open the Web Manager. Select the System screen, then select the tab Reboot & System. In the section System Configuration select the entry "Terminal Server" in the drop-down list for Serial Port to activate the terminal server. Changing the mode from terminal server to any other value during serial operation will stop the terminal server. Select the Misc screen, then select the tab Terminal Server. For Mode select "COM Port" from the drop-down list
10 For TCP Port enter the respective port. The default value is "1000". This port number has to correspondent to the respective application setting on the LAN device (i. e. PuTTY). Leaving it as default value probably won't work because this is not a standardized default value for virtual COM ports. For Data Rate select the respective rate from the drop-down list. Please refer to the serial devices documentation to determine its baud rate CLI Commands Take the following steps to configure the switch for COM port mode using the command line interface: Enable the switches serial port for terminal server use: Device.System.serial_port = TERMINAL_SERVER Changing the mode from terminal server to any other value during serial operation will stop the terminal server. For configuring the terminal server parameters change to path Management.Misc.terminal_server_config Configure the parameters as follows: Management.Misc.terminal_server_config.mode = COM_PORT Management.Misc.terminal_server_config.tcp_port = <serial device TCP port> The default value is "1000". This port number has to correspondent to the respective application setting on the LAN device. Leaving it as default value probably won't work because this is not a standardized default value for virtual COM ports. Management.Misc.terminal_server_config.data_rate = <serial device baud rate> Please refer to the serial devices documentation to determine its baud rate. For more information about configuring all serial parameters with CLI please refer to the "MICROSENS Product Manual FW G6", chapter "Misc Function" available from the Web Manager
11 4.3 COM Port Driver There are lots of possible applications for creating virtual serial ports, either open source, shareware or commercial. For the correct installation and configuration of these applications please refer to the respective user documentation. Some hardware manufacturers offer a proprietary COM port emulating software with their products. Normally these applications work with every other device too. Bear in mind that sometimes it could be necessary to disable special software features which are used to optimize the applications interaction with the manufacturers hardware
12 5 Configuration of PuTTY Take the following steps to configure PuTTY for communicating with the serial device that is attached to the MICROSENS switch in server mode. 1. Open PuTTY on your PC. 2. Open the Session dialog, enable Telnet and enter the switches IP address and the TCP port used for serial communcation. Figure 4: PuTTY Session Dialog 3. Open to the Terminal dialog and in the section Line discipline options change the setting to "Force off" for both local echo and local line editing. Figure 5: PuTTY Terminal Dialog 4. Click Open to start connecting the serial device
13 - 13 -
14 Disclaimer All information in this document is provided as is and subject to change without notice. MICROSENS GmbH & Co. KG disclaims any liability for the correctness, completeness or quality of the information provided, fitness for a particular purpose or consecutive damage. Any product names mentioned herein may be trademarks and/or registered trademarks of their respective companies 2015 MICROSENS GmbH & Co. KG, Küferstr. 16, Hamm, Germany. All rights reserved. This document in whole or in part may not be duplicated, reproduced, stored or retransmitted without prior written permission of MICROSENS GmbH & Co. KG. Document ID: AN-15003_
Application Note: Connecting to a 2500 Series Processor using PLC Workshop
Application Note: Connecting to a 2500 Series Processor using PLC Workshop This application note will describe a step by step process for the three ways to connect to a 2500-CXXX with PLC Workshop. The
Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.
Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents
IP SERIAL DEVICE SERVER
IP SERIAL DEVICE SERVER ( 1 / 2 / 4 serial port ) Installation guide And User manual Version 1.0 1Introduction... 5 1.1Direct IP mode...5 1.2Virtual COM mode...5 1.3Paired mode...6 1.4Heart beat... 6
1. MOXA NPort Express TCP/IP to RS-232 server
GS_GSR_GCR_UserManual_App_E_MOXA_V01.doc / 17.08.2009 GeoSIG Ltd. Appendix E Page E-1 1. MOXA NPort Express TCP/IP to RS-232 server 1.1. General Explanations The NPort Express RS-232/422/485 Device server
ETHERNET WEATHER STATION CONNECTIONS Application Note 33
ETHERNET WEATHER STATION CONNECTIONS Application Note 33 With WeatherLink and a Device Server INTRODUCTION It is possible to substitute an Ethernet connection for the direct USB or serial connection that
RJ45 Shielded (standard) port pinout. CS9000, Jetstream 4000 + 8500, Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX
Shielded (standard) port pinout Pin Circuit Function 1 DCD Input Data Carrier Detect 2 DSR Output Data Set Ready 3 DTR Input Data Terminal Ready 4 S/GND Signal Ground 5 TXD Output Transmit Data 6 RXD Input
Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012
Quick Note 32 Using Digi RealPort with a Digi TransPort Router UK Support September 2012 1 Contents 1 Introduction... 3 1.1 Outline... 3 1.2 Assumptions... 3 1.3 Version... 3 2 Configuration & scenario...
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
One Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
POS Integration. Prepared by: Binh Nguyen
POS Integration Prepared by: Binh Nguyen Point of Sale (POS) Compatibility To know whether it is possible to integrate your POS system with our DVR, please check whether the type of printer the POS system
LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server
Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and
3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T+ 485+ PIN6 T- 485- PIN7 R+ PIN8 R-
MODEL ATC-2004 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2004 is a 4 Port RS232/RS485 to TCP/IP converter integrated with a robust system and network management features
Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200
Linux Device Server IGW/922 with DIL/NetPC ADNP/9200 Hardware Reference SSV Embedded Systems Heisterbergallee 72 D-30453 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: [email protected]
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
RS-232 COMMUNICATIONS
Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies
DSA-1000 / PRT-1000 Device Server / Thermal Printer
LevelOne DSA-1000 / PRT-1000 Device Server / Thermal Printer User Manual V2.0 TABLE OF CONTENTS 1. INTRODUCTION...- 3-2. DEVICE OVERVIEW...- 7-3. HARDWARE SETUP...- 10-4. SYSTEM CONFIGURATION...- 12 -,
50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW-50040. Quick Installation Guide
50-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-50040 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements... 5 4. Terminal
Cable Pinouts. SRP I/O Module
Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4
Connecting and Setting Up Your Laptop Computer
CHAPTER 3 Connecting and Setting Up Your Laptop Computer This chapter explains how to connect your laptop to the Cisco Unified MeetingPlace system and how to set up your laptop so that you can use HyperTerminal.
How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline
Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications
User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS
MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed
EMG Ethernet Modbus Gateway User Manual
EMG Ethernet Modbus Gateway User Manual Rev 2.2 07/2010 CONTENTS 1. Introduction 1.1. General Features 1.2 Installing the Drivers 2. Configuration 2.1 Main Device Parameters 2.1.1 RS485 Serial Communication
Communication with BushingGard using computer USB port
Communication with BushingGard using computer USB port There are two ways of communication with BushingGard through computer USB port: Direct communication between computer USB port and BushingGard USB
ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten
ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.
Metasys System Direct Connection and Dial-Up Connection Application Note
Metasys System Direct Connection and Dial-Up Connection Application Note Code No. LIT-1201639 Software Release 5.1 Issued August 27, 2013 Supersedes October 4 2010 Refer to the QuickLIT website for the
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
Schneider OS-Loader usage via Ethernet or USB.
LHC Gas Systems 28 th February, 2007 Schneider OS-Loader usage via Ethernet or USB. Jacques ROCHEZ - IT/CO/FE Abstract This document is a guideline on how to configure correctly a PC for the use of the
MODBUS TCP to RTU/ASCII Gateway. User s Manual
MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...
DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.
DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS REV 04.11 LOCAL AREA NETWORK (LAN) CONNECTION Ethernet Connection: An Ethernet Cable, or wireless connection must
Liebert IntelliSlot Web Cards
Monitoring For Business-Critical Continuity Liebert IntelliSlot Web Cards Firmware Upgrade Manual Liebert IntelliSlot Web Card, Liebert IntelliSlot Web Card-LB, Liebert IntelliSlot Web Card-LBDS, Liebert
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
Using IDENT M System T with Modbus/TCP
Using IDENT M System T with Modbus/TCP Introduction The Pepperl+Fuchs IDENT M System T consists of two models MTT3000-F180-B12- V45-MON, which is a read only unit and the MTT6000-F120-B12-V45 which is
SSL (Secure Socket Layer)
eztcp Application Note SSL (Secure Socket Layer) Version 1.2 Sollae Systems Co., Ltd. http://www.eztcp.com Contents 1 INTRODUCTION...- 2-1.1 SSL (Secure Socket Layer)...- 2-1.2 SSL with the eztcp... -
USING THE XPERT2 / 9210B ON A TCP/IP NETWORK
1 USING THE XPERT2 / 9210B ON A TCP/IP NETWORK Prepared by: R&D January, 2009 Sutron Corporation 21300 Ridgetop Circle Sterling, Virginia 20166 TEL: (703) 406-2800 FAX: (703) 406-2801 WEB: http://www.sutron.com/
Follow these steps to prepare the module and evaluation board for testing.
2 Getting Started 2.1. Hardware Installation Procedure Follow these steps to prepare the module and evaluation board for testing. STEP1: Plug the EG-SR-7100A module into the sockets on the test board.
GSM Interfacing Board
Campus Component Pvt. Ltd. DISCLAIMER Information furnished is believed to be accurate and reliable at the time of publication. However, Campus Component Pvt. Ltd. assumes no responsibility arising from
TRP-C31M MODBUS TCP to RTU/ASCII Gateway
TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
Wifi Web Server Module w TF Socket User s Guide
Wifi Web Server Module w TF Socket User s Guide 2004-2010 Sure Electronics Inc. MB-CM14117_Ver1.0 WIFI WEB SERVER MODULE W TF SOCKET USER S GUIDE Table of Contents Chapter 1. Overview...1 1.1 Overview...
Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide
Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch IGS-5225 Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5 4. Terminal
Iridium Extreme TM Satellite Phone. Data Services Manual
Iridium Extreme TM Satellite Phone Data Services Manual Table of Contents 1 OVERVIEW... 1 2 HOW IT WORKS... 1 3 BEFORE INSTALLING... 2 4 USB DRIVER INSTALLATION... 3 5 MODEM INSTALLATION AND CONFIGURATION...
NPort s Ethernet Modem Mode
Tom Lu, Senior Engineer, Moxa Technical Support Dept. [email protected] This Tech Note applies to the following NPort models: NPort DE-211 NPort DE-311 NPort DE-311M NPort 5100 series NPort IA5150 NPort
UPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200
Remote Access Gateway IGW/922 with DIL/NetPC ADNP/9200 First Steps SSV Embedded Systems Dünenweg 5 D-30419 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: [email protected] Document
User Manual. NetCom PRO/WLAN. Edition: April 2012
User Manual NetCom PRO/WLAN Edition: April 2012 Tel: +49 40 528 401 0 Fax: +49 40 528 401 99 Web: www.visionsystems.de Support: [email protected] The software described in this manual is furnished
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
Why you need to monitor serial communication?
Why you need to monitor serial communication Background RS232/RS422 provides 2 data lines for each data channel. One is for transmitting data and the other for receiving. Because of these two separate
USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16
RS232 Serial TO Ethernet convert Module USR-TCP232-T Hard Version: V2.0 Doc Version: V1.1 2011-08-16 Jinan USR Technology Co., Ltd. works on LAN and WAN and wireless for MCU to Ethernet Solutions, Ethernet,
Ethernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2
Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface
LevelOne VOI-9000. H.323 VoIP Gatekeeper. User Manual
LevelOne VOI-9000 H.323 VoIP Gatekeeper User Manual Quick Guide Step 1: Broadband (ADSL/Cable Modem) Connections For VOI-9000 A. Connect VOI-9000 RJ45 LAN port to Router/ADSL as one of the following connections.
TOSR0X-D. USB/Wireless Timer Relay Module. User Manual. Tinysine Electronics @ 2013 Version 1.0
TOSR0X-D USB/Wireless Timer Relay Module User Manual Tinysine Electronics @ 2013 Version 1.0 INTRODUCTION This USB/Wireless Timer Relay Module allows computer control switching of external devices by using
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
HP Security Modules. Software Upgrade Guide. Part number: 5998-2259 Document version: 6PW103-20130314
HP Security Modules Software Upgrade Guide Part number: 5998-2259 Document version: 6PW103-20130314 Legal and notice information Copyright 2013 Hewlett-Packard Development Company, L.P. No part of this
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials. CHAPTER 5 OBJECTIVES Configure a router with an initial configuration. Use the
LS-101 LAN to Serial Device server. User s Manual
LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial
ezvsp User's Manual ( Version 2.1d ) Sollae Systems Co., Ltd.
ezvsp User's Manual ( Version 2.1d ) Sollae Systems Co., Ltd. Contents Chapter 1 Overview 1 1.1 Introduction 1 2.2 Key Features 2 Chapter 2 Installation 3 2.1 Ready to install ezvsp 3 2.2 Install ezvsp
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
1.1 Connection. 1.1.1 Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking
POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides
How to deploy console cable to connect WIAS-3200N and PC, to reset setting or check status via console
System s web management can also be accesses via WAN port as long as the administrator uses an IP address listed in Management IP Address List setting. If both WAN and LAN ports are unable to reach web
VPNC Interoperability Profile
StoneGate Firewall/VPN 4.2 and StoneGate Management Center 4.2 VPNC Interoperability Profile For VPN Consortium Example Scenario 1 Introduction This document describes how to configure a StoneGate Firewall/VPN
FTP Automation Guide
Products: R&S CRTU-W FTP Automation Guide with WCDMA Protocol Tester R&S CRTU-W Application Note 1CM68 This application note shows how to operate the Automation Manager tool in the R&S CRTU-W to perform
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
The Clavinova-Computer Connection
Information on using a computer with the Clavinova The Clavinova-Computer Connection What can I do using a computer with the Clavinova? What do I need to do that? How do I connect them? We will answer
PRILINK PRI Management System
www.prilink.com PRILINK PRI MANAGEMENT SSTEM INSTALLATION GUIDE PRI Management PRILINK PRI Management System Installation Guide Version 3.0, Rev. 12-01-24 Page 1 Table of Contents 1 HARDWARE INSTALLATION...
Securely manage data center and network equipment from anywhere in the world.
LES1516A LES1532A LES1548A Secure Server with Cisco Pinout Securely manage data center and network equipment from anywhere in the world. To download the user manual, this quick start guide, and software
Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel +32 16 317 411 Fax +32 16 207 164 http://www.option.com Page 1 of 14
Page 1 of 14 ! " #!"#$ % &&' Page 2 of 14 1 INTRODUCTION One of the highly desirable features of the GlobeSurfer III device is the ability to network together Printers and External Hard Disk drives (aka
FabulaTech Products Advanced Communications Solutions
FabulaTech Products Advanced Communications Solutions Network Serial Port Kit Printer for Remote Desktop Scanner for Remote Desktop Serial Port Control Serial Port Mapper Serial Port Redirector Serial
Making a DB to RJ45 adapter.
Making a DB to RJ45 adapter. DB9 to RJ45 adapters are often used in combination with a RS232 repeater for extending the distance of a serial RS232 link, but can be used for any adapter or converter purposes.
Connectors and Cables
APPENDIX B This appendix describes the connectors, cables, and adapters that you use to connect the switch to other devices. Connector Specifications 10/100 Ports The 10/100 Ethernet ports use standard
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
Guideline for setting up a functional VPN
Guideline for setting up a functional VPN Why do I want a VPN? VPN by definition creates a private, trusted network across an untrusted medium. It allows you to connect offices and people from around the
Connecting the Console Port to a PC
This document covers tasks associated with connecting a console port to a PC, and includes the following topics: Console (rollover) Cable and Adapters Making the physical connection Connecting using HyperTerminal
Software installation and configuration IEC-line series
Software installation and configuration IEC-line series update: 04-10-2014 IEC-line by OVERDIGIT overdigit.com Table of contents 1. Installing the software... 3 1.1. Installing CoDeSys... 4 1.2. Installing
Configuring the Switch with the CLI Setup Program
APPENDIXC Configuring the Switch with the CLI Setup Program This appendix provides a command-line interface (CLI) setup procedure for a standalone switch. To set up the switch by using Express Setup, see
Keri USB-A Connection and Configuration
Step 1 - Connect the KPC-1 cable to the K-USB. NOTE: The form of the USB converter may vary, so the unit you receive may not be identical to the one displayed here. Step 2 Plug the USB Connector of the
Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM
Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation
Pre-lab and In-class Laboratory Exercise 10 (L10)
ECE/CS 4984: Wireless Networks and Mobile Systems Pre-lab and In-class Laboratory Exercise 10 (L10) Part I Objectives and Lab Materials Objective The objectives of this lab are to: Familiarize students
IP Serial Server. User Manual
IP Serial Server IPS-101 (1-port) IPS-102 (2-port) IPS-201 (1-port) IPS-202 (2-port) IPS-204 (4-port) User Manual V2.0 2009.03.09 Page: 1 / 62 Copyright This document contains proprietary information that
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
PortShare Software Quick Start Guide. PortShare
PortShare PortShare Software Quick Start Guide Use with LES1101A, LES1102A, LES1108A, LES1116A, LES1132A, LES1148A, LES1208A, BLACK LES1216A, BOX LES1232A, LES1248A, LES1202A, LES1203A-11G, LES1204A-3G,
OpenCPN Garmin Radar Plugin
OpenCPN Garmin Radar Plugin Hardware Interface The Garmin Radar PlugIn for OpenCPN requires a specific hardware interface in order to allow the OpenCPN application to access the Ethernet data captured
Encore Controller to Router Connections
Encore Presentation System Encore Controller to Router Connections Contents: Scope... 2 EXT COMM Pinouts... 2 Cable Connection Straight Through... 3 Cable Connection Null Modem... 3 Lantronix Ethernet
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
Adafruit's Raspberry Pi Lesson 5. Using a Console Cable
Adafruit's Raspberry Pi Lesson 5. Using a Console Cable Created by Simon Monk Last updated on 2014-09-15 12:00:13 PM EDT Guide Contents Guide Contents Overview You Will Need Part Software Installation
Ethernet 241 (USB/Serial) Quick Start Guide
Ethernet 241 (USB/Serial) Quick Start Guide I. Ethernet 241 Device Overview The Ethernet 241 device is a two port switch that interfaces a networked device (such as a printer) with a networked device server,
Applicazioni Telematiche
Angelo Coiro Laboratorio Applicazioni Telematiche L emulatore Packet Tracer Packet Tracer Cisco Packet Tracer is an academic software that allows to emulate Cisco devices Packet Tracer can be used for
NPort DE-311 Hardware Installation Guide
NPort DE-311 Hardware Installation Guide Fourth Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. NPort DE-311 Hardware Installation
Cisco Expressway CE500 Appliance
Cisco Expressway CE500 Appliance Installation Guide First Published: April 2014 Last Updated: November 2015 X8.2 or later Cisco Systems, Inc. www.cisco.com Introduction About This Document This document
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
Interfacing Basler GigE Cameras With Cognex VisionPro 7.2
www.baslerweb.com Interfacing Basler GigE Cameras With Cognex VisionPro 7.2 This Application Note explains how to interface a Basler camera with GigE interface with the Cognex VisionPro 7.2 software package
Cabling Guide for Console and AUX Ports
Cabling Guide for Console and AUX Ports Contents Introduction Prerequisites Requirements Components Used Conventions Table of Routers with Console and AUX Ports Console Port Settings for Terminal Connection
Prestige 314 Read Me First
Prestige 314 Read Me First Console WAN 10M PORT Prestige Rear Panel Connections CONNECTION Use an RS-232 console cable. Use the cable that came with your broadband modem. LAN 10/100M Port Number COMPUTER
Installation and operation manual
Installation and operation manual Converter I-7188En-MGTCP Modbus TCP to Modbus RTU Gateway and Router I-7188En-MRTCP Modbus RTU to Modbus TCP Router. GDAŃSK 09.2006 v. 2.0.1. strona 1z1 TABLE OF CONTENTS
SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2
SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.11 September 13, 2006 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998,
isco Connecting Routers Back to Back Through the AUX P
isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1
Quick Start Guide. Quick Start Guide. taskit GmbH. for Portux920T EU / SW Portux Mini-PC Portux Panel-PC Panel-Card MoLUX Stamp
Quick Start Guide for Portux920T EU / SW Portux Mini-PC Portux Panel-PC Panel-Card MoLUX Stamp Page 1 of 15 Version 1.14 Seelenbinderstr. 33 D-12555 Berlin Germany Tel. +49 (30) 611295-0 Fax +49 (30) 611295-10