Data Center Solutions - The Containerized Evolution Power IT Cooling 7 th Green Connected World Tsikogias Thanassis Data Centers Solutions Architect, IT Business Athens 2015 1
We are the global specialist in energy management 25 billion revenue (FY 2014) 170 000+ employees in 100+ countries 5% of sales dedicated to R&D A large company, with a balanced geographical footprint and a commitment to sustainability 2
Schneider Electric Greece More than 45 years in the Greek market Operating in 2 entities (Commercial & Industrial) Local Production Site at Inofita (Oil type transformers factory) 1976 The former ElVIM plant joins the Schneider Electric Group for the production of oil type transformers 3 3
Moving from Products to Complete Market Solutions Energy Power Industry Data Centers Buildings 4
Schneider Electric Solutions for the New Generation of Data Centers What is Prefabrication? 5
Three major applications for prefab Ruggedized, Mobile Solutions for Industrial, Government, Emerging Economies, Manufacturing Scalable Solutions for Service Providers and Large Scale Deployments Quick Deploy, Pre-Engineered Solutions for S/M Enterprise, Healthcare, Education 6
Product Offer 7
Cooling IT Space Power One-Size Does Not Fit All 100kW 1.2MW 5 Racks 200 Racks DX Chilled Water Direct Air Indirect Air 8
Power Modules - Base Designs Power Modules 100kW 20ft Enclosure with UPS, Switchgear, cooling, DCIM 500kW 40ft Enclosure with UPS, Switchgear, cooling, DCIM 1.2 MW Skid mounted, UPS, Switchgear, DCIM 9
Enclosed Power Modules Air Conditioners 500kW Module Critical Output Switchboard 500kW Symmetra PX UPS Symmetra N+1 UPS(250/500kW) 5 min Runtime Switchboard w/ integrated ATS Power monitoring, management and controls Environmental cooling Fire Suppression UL Listed Fire Suppression System Primary Switchboard 10
IT Module - ISO Shipping Container Overview ISO shipping container is defined to 8ft wide and lengths of 10ft, 20ft, 40ft. Containers are designed to be strong, rugged, environmentally sound and easily transportable anywhere in the world 8ft width limits usable space for hot and cold aisles. Height is also limited Schneider has unique solutions for slide racks and flexible cable trays to allow full access to front and rear of racks to overcome space limitations Overhead cooling units (DX and CW) are available to maximize rack space 11
IT Module - Non ISO Overview Non-ISO design is wider, taller, deeper than container and engineered to provide a spacious, functional workspace for IT personnel Efficient, scalable design allows for custom, multimodule configurations from 5 240 racks Multiple cooling solutions for chilled water, DX and air economization (In-row, Perimeter, End-of-Row) Robust frame design simplifies installation and ganging together Best option for a complete configurable space. 12
IT Module - Modular Room Overview Quickly add secure data centre rooms to a minimal finished building All wall panels, ceiling, and doors are pre-engineered to meet customer specs and delivered on-site for fast assembly All of the advantages of a modular build Scalable, simple design and deployment, and preserve Capex with the all of the flexibility of a traditional IT space Highly Secure Fire rated, Water-tight, Dust-tight Energy Efficient minimal thermal transmission losses Cleaner installation than traditional build no construction, conservation of materials 13
IT Module Detail 2 bay, In-Row, 240kW shown 24 NetShelter Racks Aisle Containment 240kW cooling capacity 400V distribution @11kW per rack (2N) Power monitoring, management and controls Fire detection and suppression Staging lobby for outside isolation Staging Lobby and Electrical Room In-Row Cooling Units 400V Modular Power Distribution 14
Cooling Modules Cooling Modules Hydronics Modules Chiller Skids & Enclosures Packaged Chiller, pump, and Tank with connecting piping 100kW 1.2 MW Packaged Air Cooled Chillers - Options with and without free cooling Ecobreeze ISO frame 15
Base Designs - Hydronics Module Available in Tier II Tier III Tier IV Hydronics Module Mechanical Packaging designed to handle flow rates based on design loads based on pipe size Pumps and Electrical will be configured based on specific customer Requirements Chillers (install in field) Enable Greater Flexibility to handle Varying load and ambient conditions Utilize 3 rd party chillers as required Thermal Storage Option Provides flexibility to offer as required Adaptable to different ride through requirements Initial design based on 5min 16
StruxureWare DCIM Integrated in each Prefabricated Building Block 17
Prefabricated Data Center Advantages Flexibility and Scalability Faster Deployment Predictable Performance Defer capital expenses and minimize over sizing. Adjust quickly changes in your demand, up or down. Build in smaller, more granular phases Shorten planning cycle and reduce complexity Simplify build process Delivery in 16-20 weeks or less (upon design sign-off and receipt of PO) The density, availability and efficiency you expected The cost you were promised Less hands involved, less changes to design... vs. traditional data centers 18
5 Compelling Reasons to Choose Schneider Electric for Your Prefabricated Data Center 14 Years proven experience in prefabricating data centers Broad offer of customizable Prefabricated Building Blocks Global capabilities - supply chain, design, applications and engineering support StruxureWare for Data Centers - award winning DCIM software suite Extensive library of Prefabricated Data Center reference designs to 19
References 20
Louros Green Data Center The Project Cooling through River Water PUE < 1.3 Containerized Solution Increased Availability Deployment in less than 25 weeks Power, Cooling & IT Module Personnel Module & Substation Chiller as back-up DCIM 5 years Remote Monitoring Services 21
Support by Schneider Electric 22