Energy Management Energy Meter Type EM23 DIN



Similar documents
Energy Management Energy Analyzer Type EM24 DIN

Energy Management Power Analyzer Type WM14-96 Basic Version

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Panel Meters and Controllers Modular Panel Meter Type EDM 35

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

38 Series - Relay interface modules A

Power Meter Series 700

38 Series - Relay interface modules A

RM4TG20 three-phase network control relay RM4-T - range V

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

A project to optimise quality and energy efficiency must include metering

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Quick Connect. quick - simple - efficient.

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Three-phase monitoring relay CM-PFE

Polyphase kwh Electricity Meter

MasterINTERFACE 39 Series - Relay interface modules

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

3-phase, bidirectional energy meter

MasterINTERFACE 39 Series - Relay interface modules

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Telephone- and leased line modem for industrial applications TD-36

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

48 SERIES Relay interface modules 10 A

Analog signal converters CC-E I/I Current / current isolators

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Applications. diris_826_a_1_gb_cat

Relés e Contatores de Estado Sólido SIRIUS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Installation manual. Generator Paralleling Controller GPC multi-line C

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

B21 User Manual Document ID: 2CMC485004M0201 Revision: A

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Maximum Demand Control

Bulletin 150 SMC Flex Smart Motor Controller Specifications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

3-Phase Energy meter with serial S-Bus interface

Cable Solutions for Servo and Variable Frequency Drives (VFD)

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Features. Picture. Specifications

ADM1TE 5/30A DIN rail single phase two wire energy meter

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual

Voltage Regulator SPAU 341 C. Product Guide

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Rack mounted telephone- and leased line modem for industrial applications

15 Series - Electronic step relay and dimmer. Features SERIE

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Measurement of Power in single and 3-Phase Circuits. by : N.K.Bhati

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Preset Counter signo 721

80 Series - Modular timers 16 A. Features

smart-house Controller Central Unit Module Type SH2WEB24

Installation and operating instructions

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

80 Series - Modular timers 16 A. Features

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

BB800 Off-Grid Solar System

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

Indoor / Outdoor Antenna

SINEAX U553 Transducer for AC Voltage

CompactLogix Power Supplies Specifications

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Multifunction devices

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Multifunction Digital Timer

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

49 Series - Relay interface modules A. Features

Transcription:

Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy analyzer Instantaneous variables readout: 3 DGT Energies readout: 6+1 DGT System variables: W, var, Phase-sequence. Single phase variables: A Energy measurements: total kwh and kvarh TRMS measurements of distorted sine waves (voltages/currents) Self power supply 1 pulsating output Dimensions: 4-DIN modules Protection degree (front): IP50 Easy connections management MID annex MI-003 (Measuring Instruments Directive) compliant Product Description Three-phase energy meter with built-in configuration joystick and LCD data displaying; particularly indicated for active and reactive energy metering and for cost allocation. Housing for DINrail mounting with IP50 (front) protection degree. Direct connection up to 65A. Moreover the meter is provided with one pulsating output proportional to the active energy being measured. How to order EM23 DIN AV9 3 X O1 X Model Range code System Power supply Output Option Type Selection Range codes System Output Power supply AV9: 400V LL AC - 10(65)A (Direct connection) 3: balanced and unbalanced load: 3-phase, 4-wire; 3-phase, 3-wire; O1: open collector type (single pulse output) X: Self power supply -15% +20% of the rated measuring input voltage, 45 to 65 Hz Options X: none Specifications are subject to change without notice EM23DINDS 251007 1

Input specifications Rated inputs System type: 3 Current type By direct connection Voltage 400 VLL AC Current range (direct) 10 (65)AAC Accuracy (Display) Ib: see below, Un: see below (@25 C ±5 C, R.H. 60%, 48 to 62Hz) AV9 model Ib: 10A, Imax: 65A; Un: 184 to 276VLN (318 to 480VLL) Current Phase-neutral voltage Phase-phase voltage Active power Reactive power Active energy Reactive energy Energy additional errors Influence quantities Temperature drift Sampling rate Display refresh time Display Type Instantaneous variables read-out Energies From 0.004Ib to 0.2Ib: ±(0.5% RDG +3DGT) From 0.2Ib to Imax: ±(0.5% RDG +1DGT). In the range Un: ±(0,5% RDG +1DGT) In the range Un: ±(1% RDG +1DGT) ±(1%RDG +2DGT) ±(2%RDG +2DGT) Class 1 according to EN62053-21 and Class B MID Annex MI-003 Class 2 according to EN62053-23 Ib: 10A, Imax: 65A; 0.1 Ib: 1,0A, Start up current: 40mA According to EN62053-21, EN62053-23 and EN50470-1-2 200ppm/ C 1600 samples/s @ 50Hz 1900 samples/s @ 60Hz 750 msec. 2 lines (1 x 7 DGT; 1 x 3DGT) LCD, h 9mm 3 DGT Imported: 6+1DGT or Overload status Max. and Min. indication LEDs Measurements Method Coupling type Crest factor Current Overloads Continuous For 10ms Voltage Overloads Continuous For 500ms Input impedance 400VL-L 7DGT; EEE indication when the value being measured is exceeding the Continuous inputs overload (maximum measurement capacity) Max. instantaneous variables: 999; energies: 999 999.9 or 9 999999. Min. instantaneous variables: 0; energies 0.0 Red LED (Energy consumption), 1000 imp./kwh Max frequency: 16Hz according to EN50470-1 See List of the variables that can be connected to: TRMS measurements of distorted wave forms. Direct Ib 10A 4 (91A max. peak) 65A, @ 50Hz 1920A max, @ 50Hz 1.2 Un 2 Un Refer to Power Consumption 10(65) A < 4VA Frequency 45 to 65 Hz Joystick For variable selection. Output specifications Digital outputs Pulse type Number of outputs Type Pulse duration 100 pulses per kwh (0.01kWh/pulse). Output connected to the active energy 100ms < 120msec (ON), 120ms (OFF), according to EN62053-31 Static output Purpose Signal Insulation For pulse output V ON 1.2 VDC/ max. 100 ma V OFF 30 VDC max. By means of optocuplers, 4000 VRMS between output to measuring inputs. 2 Specifications are subject to change without notice EM23DINDS 251007

Software functions System selection System 3-Phase unbalanced load 3-phase (4-wire); 3-phase (3-wire). Displaying Up to 3 variables per page Easy connection function Automatic phase sequence detection with current and voltage synchronisation. Both energy and power measurements are independent from the current direction. The displayed energy is always imported General specifications Operating temperature Storage temperature Installation category Insulation (for 1 minute) Dielectric strength Noise rejection CMRR EMC Electrostatic discharges Immunity to irradiated Electromagnetic fields Burst Immunity to conducted disturbances -25 C to +55 C (-13 F to 131 F) (R.H. from 0 to 90% non-condensing @ 40 C) according to EN62053-21 and EN62053-23 -30 C to +70 C (-22 F to 140 F) (R.H. < 90% noncondensing @ 40 C) according to EN62053-21 and EN62053-23 Cat. III (IEC60664, EN60664) 4000 VRMS between measuring inputs and digital output 4000 VRMS for 1 minute 100 db, 48 to 62 Hz According to EN62052-11 15kV air discharge; Test with current: 10V/m from 80 to 2000MHz; Test without any current: 30V/m from 80 to 2000MHz; On current and voltage measuring inputs circuit: 4kV 10V/m from 150KHz to 80MHz Surge On current and voltage measuring inputs circuit: 4kV. Radio frequency suppression According to CISPR 22 Standard compliance Safety IEC60664, IEC61010-1 EN60664, EN61010-1 EN62052-11 Metrology EN62053-21, EN62053-23, MID annex MI-003 Pulse output DIN43864, IEC62053-31 Approvals CE Connections Screw-type Cable cross-section area Max. 16 mm 2 Min. 2.5 mm 2 (measuring inputs); Min./Max. screws tightening torque: 1.7 Nm / 3 Nm Output terminals: 1.5 mm 2 Min./Max. screws tightening torque: 0.4 Nm / 0.8 Nm Housing DIN Dimensions (WxHxD) 71 x 90 x 64.5 mm Material Nylon PA66, self-extinguishing: UL 94 V-0 Mounting DIN-rail Protection degree Front IP50 Screw terminals IP20 Weight Approx. 400 g (packing included) Power supply specifications Self supplied version Note O1 option only: -15% +20% of Un, 48-62Hz. The instrument provided with O1 option, working Power consumption in a 3-phase system with neutral may work also if one or two phases are missing. 20VA/1W Specifications are subject to change without notice EM23DINDS 251007 3

Accuracy (according to EN62053-21 and EN62053-23) kwh, accuracy (RDG) depending on the current +1,5% +1% 0% -1% -1,5% Error kvarh, accuracy (RDG) depending on the current +2,5% +2% 0% -2% -2,5% Error PF=1 0.5A 1A 65A (Imax) sinϕ=1 0.2A 0.5A 65A (imax) PF=L0.5 or C0.8 1A 2A Accuracy limits (Active energy) Start-up current: 40mA 65A (Imax) sinϕ=0.5 0.5A 1A Accuracy limits (Reactive energy) Start-up current: 40mA 65A (Imax) MID Annex MI-003 compliance Accuracy 0.9 Un U 1.1 Un; 0.98 fn f 1.02 fn; fn: 50 or 60Hz; cosϕ: 0.5 inductive to 0.8 capacitive. Class B I st: 0.04A; I min: 0.5A; I tr: 1A; I max: 65A. Operating temperature EMC compliance -25 C to +55 C (13 F to 131 F) (R.H. from 0 to 90% non-condensing @ 40 C) E2 List of the variables that can be connected to: Pulse output (only Eneries ) No Variable 3-ph. 4-wire bal. system 3-ph. 4-wire unbal. system 3 ph. 3-wire bal. system 3 ph. 3-wire unbal. system Notes 1 A L1 x x x x 2 A L2 x x x x 3 A L3 x x x x 4 var sys x x x x sys=system 5 W sys x x x x sys=system 6 Phase seq. x x x x 7 kwh x x x x Total 8 kvarh x x x x Total (x) = available (o) = not available (zero indication on the display) 4 Specifications are subject to change without notice EM23DINDS 251007

Display pages Display variables in 3-phase systems with or without neutral No 1 st line 2 nd line Phase Sequence Notes 1 Total kwh kw sys 2 Total kvarh kvar sys 3 AL1 - AL2 AL3 Warning triangle if reverse sequence Warning triangle if reverse sequence Warning triangle if reverse sequence Note: whatever page the user has selected, after 60s it goes back to page 1. Additional available information on the display Type 1st line 2nd line Meter information 1 Serial number Year of production Pulse output Pulse output 1 Insulation between inputs and outputs Measuring Inputs Open collector outputs Self power supply Measuring Inputs - 4kV 0kV Open collector outputs 4kV - 4kV Self power supply 0kV 4kV - Wiring diagrams 3-ph, 4-wire, unbal./bal. load Fig.1 3-ph, 3-wire, unbal./bal. load Fig. 2 65A inputs self power supply Specifications are subject to change without notice EM23DINDS 251007 5

Open collector output wiring diagrams Open Collector VDC Open Collector VDC The load resistances (Rc) must be designed so that the close contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC. GND reference Front panel description VDC reference 3 2 1 1. Joystick To scroll the variables on the display. 2. LED Red LED blinking proportional to the energy being measured. 3. Display LCD-type with alphanumeric indications to display all the measured variables. 4. Connections Screw terminal blocks for instrument wiring. 4 Dimensions 6 Specifications are subject to change without notice EM23DINDS 251007