Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety



Similar documents
Our full line of JS Popper test products enables you to monitor circuits without taking them offline

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

THE OLDAKER DIFFERENCE.

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

DIRECTCONNECT SERVICE

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

PROTECH ELECTRICAL CONNECTORS AND CABLE TIES

Hook-Up and Lead Wire

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Motor Protection Voltage Unbalance and Single-Phasing

Waekon Gold. Test Lead Master Kit. Tight Spot Test Lead Kit. Micro Mate Terminal Adapter Set. Magnetic Test Lead Ground Lug

Universal MATE-N-LOK Connectors

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

SAFETY SAFETY APPAREL 20,000 PSI

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

Order Desk: 1 (800) 995-HOOK. E-Z-Link & Tap-A-Dip...57 Multi-lead Test Systems...58

Tubing and Accessories

Standard Buccaneer - Ethernet

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

CHAPTER 2 EXAMPLES AND TABLES

Using and Wiring Light Emitting Diodes (LEDs) for Model Railroads

Cables and Accessories Selection Guide

Directory chapter 04

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

bba - Balboa Bluetooth Audio (AMP) Installation & User Guide

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Companion Service Guide

Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

The range of rail-mounted terminal blocks. for a perfect electrical installation.

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Technical Update TAA.TU Rev. 1

Ergonomical Polyurethane recoil hose

Custom Cable Assemblies for Medical Applications and more.

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I.

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies

19-PIN. PLS 19-pin connector series. Features: SOLDER TYPE CRIMP TYPE PLS-5219LM PLS-5219CLM PLS-5219CLF PLS-5219LF PLS-5219SM PLS-5219CSM

Short Circuit Current Calculations

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LIEBERT VNSA Installation Sheet

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

08. SEK IDC CONNECTORS

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

STREETLIGHT SYSTEM GROUNDING AND BONDING

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Co-location Interconnect Power Panel (CIPP) Installation Guide

Contact Information: Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.

Outside Telephone Cable

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

Instrumentation Cable Power Cable Assembly Solutions...32

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

How To Power A 12 Volt Relay On A Car Or Truck

400 Series Buccaneer BUCCANEER POWER. bulgin

Three-Phase Electric Power Distribution for Computer Data Centers

Comparative study for cables and busbars

Electrical Safety Products

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

mpm DIN CONNECTORS

400 Series - Mini USB Buccaneer

Current Monitoring Kit QUICK START GUIDE

Installation and Operating Instructions (for chargers shown below)

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Building Cables and Wires

Cables. Accessories. For Force, Torque and Strain Sensors

The Performance of Voltage Rated Gloves in Arc Flash Exposures

Current Monitoring Kit

i ChatterBox! Motorcycle Security

Tape Wound, Split Core and Ebony Current Transformers

CIN::APSE MICROMINIATURE D-SUB

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

MapIT G2 Infrastructure Management

CDGRD-10. Grounding. Solutions For Comm/Data Applications

Extension Cord Safety Policy

Installation and Operating Instructions (for chargers shown below)

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Generator DoCKInG StatIonS

Model RI ICE Pack Impressed Current Electronic Package the remedy for Mag headaches Typical Applications:

Thermocouple Wire & Cable

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

The Different Types of AC Power Connectors in North America

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems, Inc. test equipment offers outstanding performance, flexibility, and value. Our test leads offer nothing less. Carefully engineered from the ground up, they combine performance, safety, and economy, to make your job simpler. All components are carefully selected to work well together, resulting in long life and excellent reliability. Arbiter Systems' test lead products improve operator safety and ease of use. The Fused Safety Voltage Probe Lead Sets offer in-line, class CC fuse holders with 200,000 ampere interrupting capacity to help prevent hazardous high-energy arc faults. The Universal Test Plug Current Lead Sets, compatible with all common series make-before-break test jacks, offer improved ruggedness for long life and color coding by phase to simplify test setups. The test lead sets are made with rope-lay, ultra-fine stranded wire and your choice of silicone or Santoprene insulation for flexibility over a wide range of temperatures. As an added feature, the flameretardant PET monofilament armor protects the test leads from damage, such as abrasion and cut-through, a particularly important feature when testing high-energy feeder or service entry circuits and relaying CT secondaries. Only the highest-quality components are used in our test lead assemblies. All current-carrying hardware is made of copper-based alloys for the best conductivity. Mechanical hardware is stainless steel for strength and corrosion resistance. Crimp terminals are made from seamless copper tubing, and a copper foil wrap ensures proper termination of finely-stranded wires. Heat-shrink tubing is top-quality clear fluoroplastic, not cheaper alternatives. All connections are provided with strain relief for the wire insulation, and all insulating materials are high-temperature, non-burning materials. Voltage lead sets have color-coded wire, connectors, and accessories, and every current test lead set includes color-coded heat shrink markers at each connection, with phase indication hot-stamped into the material. Where for other manufacturers test leads may be an afterthought, we have put the same care into designing and selecting the components for our test leads that we put into all of our products. Arbiter Systems' lead sets are available as complete assemblies. Also, we will custom assemble test lead sets to your specification. Whether you choose our standard test lead sets, or custom assemblies, you can buy with confidence, knowing that better safety and finer quality are not available at any price. Santoprene and Silicone Test Lead Wire Arbiter Systems offers test lead wire with your choice of two insulation types, Santoprene and silicone. Both silicone and Santoprene insulated lead wires are made using finely-stranded rope-lay copper conductors for exceptional flexibility and limpness. Both insulations retain outstanding flexibility and insulation properties over a wide range of temperatures. We use extra-heavy insulation for an extra margin of safety, and both insulation types are available in colors to coordinate with the input connections on our instruments. Regardless of your choice in insulation, our test lead wires will deliver long, satisfactory service in the field. Silicone is our premier test lead wire. Highly flexible over a wider range of temperatures (-70 to +150 C, -100 to +300 F) than any other flexible insulation material, with excellent resistance to damage due to flame and heat, our silicone wire is highly recommended where safe operation is required with the possibility of high-current through faults. Silicone is nonflammable, and will not emit toxic or irritating fumes at extreme temperatures or under overload conditions. For most applications, our Santoprene insulated test lead wire is a cost-effective alternative to silicone, offering most of the same advantages at a price which compares favorably with PVC, neoprene, and other lower-quality insulations. Because Santoprene is a thermoplastic rubber, however, it will melt at a temperature of+216 C (+421 F), and it is primarily recommended for use in applications where high-current faults are less likely. Santoprene offers excellent resistance to arc ignition and good resistance to ignition by a hot wire. And, unlike PVC or halogenated rubber compounds, Santoprene does not emit toxic and irritating fumes when it is overheated or burned, and it is inherently self-extinguishing. 60

General Specifications Silicone Insulated Lead Wire AWG #10, 1064 x #40 stranding, 1.15 mm (0.045 in.) silicone insulation; 5.8 mm (0.230 in.) OD. AWG #16, 665 x #44 stranding, 1.5 mm (0.060 in.) silicone insulation; 4.8 mm (0.187 in.) OD. Santoprene Insulated Lead Wire AWG #10, 1666 x #42 stranding, 1.15 mm (0.045 in.) Santoprene insulation; 6.1 mm (0.240 in.) OD. AWG #16, 665 x #44 stranding, 1.5 mm (0.060 in.) Santoprene insulation; 4.8 mm (0.187 in.) OD. Length All lead sets are 2.5 m (8 feet) long, standard. For other lengths, consult the factory. Color Code Voltage leads: wire insulation color is; red/aø, yellow/ Bø, blue/cø, white/n (three-phase); red/line, white/ neutral (single-phase). Current leads: wire insulation color is gray; leads are supplied in pairs with colored phase markers on each pair (red/aø, yellow/bø, blue/cø) and colored polarity markers on each (+) lead (red, yellow, or blue) and (-) lead (black). PET Armor Lead sets are cabled with an overall PET monofilament braided armor for protection against abrasion and cutthrough, except where noted. Our PET armor is strong and highly flexible; when properly installed, it protects the enclosed wires while maintaining flexibility. Armor is medium gray color. Velcro Lead Straps Lead sets are also provided with multipurpose Velcro lead straps. This strap may be used to lash the lead set when it is coiled for storage. It may also be used to support the lead set when in use, by tying off to a convenient anchor point. When not in use, the lead strap may be wrapped around itself to keep it from dangling. 61

Universal Test Plug Current Lead Sets Model 811A - Santoprene Universal Test Plug Current Lead Set Single-phase current lead equipped with our Universal Test Plug (compatible with ABB/Westinghouse, Superior, Meter Devices, and States series test jacks) on one end and 1/4 in. spade lugs on the other. This lead set is assembled with #10 Santoprene lead wire; overall gray PET armor and Velcro lead strap. Order Model 811AA (red/aø), 811AB (yellow/bø), 811AC (blue/cø); or, for a three-phase set, 811AT (one 811AA, one 811AB, and one 811AC). Model 811C - Silicone Universal Test Plug Current Lead Set Offers the same features as the Model 811A Universal Test Plug Current Lead Set. This lead set is assembled with #10 Silicone lead wire in place of the #10 Santoprene lead wire. Order Model 811CA (red/aø), 811CB (yellow/bø), 811CC (blue/cø); or, for a three-phase set, 811CT (one 811CA, one 811CB, and one 811CC). Spade Lug Current Lead Sets Model 816A - Santoprene Spade Lug Current Lead Set Single-phase current lead equipped with our 0.25 in. spade lugs on the both ends. Spade lugs are goldplated for long life in demanding service, and have oversized barrels to accommodate our finely-stranded test lead wire. This lead set is assembled with #10 Santoprene lead wire; overall gray PET armor and Velcro lead strap. Order Model 816AA (red/aø), 816AB (yellow/bø), 816AC (blue/cø); or, for a three-phase set, 816AT (one 816AA, one 816AB, and one 816AC). Model 816C - Silicone Spade Lug Current Lead Set Offers the same features as the Model 816A Spade Lug Current Lead Set. This lead set is assembled with #10 Silicone lead wire in place of the #10 Santoprene lead wire. Order Model 816CA (red/aø), 816CB (yellow/bø), 816CC (blue/cø); or, for a three-phase set, 816CT (one 816CA, one 816CB, and one 816CC). 62

Safety Voltage Probe Lead Sets Model 813AT - Santoprene Three-Phase Safety Voltage Probe Lead Set Three-phase, 4-wire lead set that provides safetyshrouded stackable 4 mm banana plugs on both ends of the lead, includes various plug-on accessories compatible with the 4 mm banana plugs. This lead set is assembled with #16 Santoprene lead wire; overall gray PET armor and Velcro lead strap. Intended primarily for applications where high-energy faults are unlikely. For high-energy applications, see the Model 815AT Three-Phase Fused Safety Voltage Probe Lead Set. Model 813BT - Silicone Three-Phase Safety Voltage Probe Lead Set Offers the same features as the Model 813AT Three- Phase Safety Voltage Probe Lead Set. This lead set is assembled with #16 Silicone lead wire in place of the #16 Santoprene lead wire. Fused Safety Voltage Probe Lead Sets Model 815AT - Santoprene Three-Phase Fused Safety Voltage Probe Lead Set Three-phase, 4-wire, fused lead set that provides safety-shrouded stackable 4 mm banana plugs on both ends of the lead, includes various plug-on accessories compatible with the 4 mm banana plugs. This lead set is assembled with #16 Santoprene lead wire; overall gray PET armor and Velcro lead strap. The fuse feature provides 200,000 amps interrupting capacity for improved safety with high fault energy feeder or service entrance circuits. Clear PVC barrel allows verification of installed fuse type. The neutral is not fused. Includes 1 amp fuse (spares sold separately). Accepts class-cc rejection fuses only. Rated current: 2 amps continuous. NOT for use in current-transformer circuits, except for burden voltage (non-current-carrying) tests. Model 815BT - Silicone Three-Phase Fused Safety Voltage Probe Lead Set Offers the same features as the Model 815AT Three- Phase Fused Safety Voltage Probe Lead Set. This lead set is assembled with #16 Silicone lead wire in place of the #16 Santoprene lead wire. 63

Safety Ground Leads Model 812G Twist-Clamp Safety Ground Lead Single lead equipped with 1/4 in. spade lug on one end and a twist-lock test clamp grounding connector on the other. Spade lug is gold-plated for long life in demanding service, and has an oversized barrel to accommodate our finely-stranded test lead wire. This lead is assembled with #10 Santoprene lead wire. Model 812H Clip-Type Safety Ground Lead Single lead equipped with 1/4 in. spade lug on one end and a Mueller #27C copper grounding clip on the other. Spade lug is gold-plated for long life in demanding service, and has an oversized barrel to accommodate our finely-stranded test lead wire. This lead is assembled with #10 Santoprene lead wire. Accessories Series Test Jack Isolator Paddles Model 841A A bag of 12 individual insulators. Model 842A A set of three insulators bound together with a 60 cm (24 in.) length of nylon cord and dayglo orange REMOVE AFTER TEST placard. Model 842B A set of four insulators bound together with a 60 cm (24 in.) length of nylon cord and dayglo orange REMOVE AFTER TEST placard. Insert this orange thermoplastic insulator into a series test jack (Superior, ABB/Westinghouse, Meter Devices, or States) to isolate the two blades of the jack for testing. Bright orange color for high visibility, even in poor lighting. Tough acetal resin has low coefficient of friction for easy use. Has a 5 mm (0.197 in.) hole on the end for a key chain or cord. Model 812H 64