MH - Gesellschaft für Hardware/Software mbh



Similar documents
The Universal DAQ Device. Connect and measure immediately!

NEW. EVEN MORE data acquisition and test stand automation

Trigno/Vicon System Integration

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

Simplify Data Acquisition with a Built-in LXI Web Server

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Measuring Temperature withthermistors a Tutorial David Potter

PRODUCT SHEET.

NETWORK ENABLED EQUIPMENT MONITOR

EBERSPÄCHER ELECTRONICS automotive bus systems. solutions for network analysis

NetScanner System. Toronto: , Montreal: , Toll Free: ,

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.

IsumaTV. Media Player Setup Manual COOP Cable System. Media Player

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

DVI KVM Switches DP-MUX 7.4

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Web:

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide

Video VBOX Pro RLVD10P2P/RLVD10P2PV/RLVD10P4PV/RLVD20P2PV/RLVD20P4PV. Features

EagleVision Mobile DVR Security system With GPS Tracking & Data analysis m

The Director Software V4 and the Scalability Tool

1 Technical Description Lokal-200PC

Generic Procurement Specification for a. Video Vehicle Detection System. For Road Traffic Applications

High voltage tester HA 1800 Table-top device

ECONseries Low Cost USB DAQ

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

MoveInspect HF HR. 3D measurement of dynamic processes MEASURE THE ADVANTAGE. MoveInspect TECHNOLOGY

Research-Grade Research-Grade. Capture

Introduction to Data Acquisition

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Vehicle data acquisition using CAN By Henning Olsson, OptimumG

T-REDSPEED White paper

In regard to calculating system power requirements, refer to DBK Basics located near the front of this manual.

Dash 8Xe / Dash 8X Data Acquisition Recorder

MANUAL FOR RX700 LR and NR

Amcrest 960H DVR Quick Start Guide

SNC-VL10P Video Network Camera

Chapter 5 Cubix XP4 Blade Server

[Download Tech Notes TN-11, TN-18 and TN-25 for more information on D-TA s Record & Playback solution] SENSOR PROCESSING FOR DEMANDING APPLICATIONS 29

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

SCD Server. SCD Server Pro

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

How To Sell A Talan

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

4 Port full HD multiviewer real-time USB/KVM switch

US-Key New generation of High performances Ultrasonic device

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

On-line Machine Condition Monitoring [The CMS System]

sontheim Wir leben Elektronik! We live electronics! Industrie Elektronik GmbH Computer-on-Modules Overview of our Computer-on-Modules

Driver Pant 8 and antenna switcher Ant 8. User manual

Programmable Logic Controller PLC

NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range

Understanding Network Video Security Systems

Digital Video Recorder

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

8/16-Port IP KVM Switch IKVM-8010 / IKVM Quick Installation Guide

ABB RTU560A Series CMU & Modules

VX 2400 Dimmer User's Manual

PRODUCT SHEET OUT1 SPECIFICATIONS

STM32L. Ultra-low-power Cortex -M3 devices

Kaleido-Alto: 10-input, highly affordable multi-image display processor

THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS

TiIrydeTouchPhone. User guide 10/11-01 PC

3D Laser Scanning Technology. Rugged hardware and powerful software combined with streamlined survey workflow

WISE-4000 Series. WISE IoT Wireless I/O Modules

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Products. CM-i586 Highlights. Página Web 1 de 5. file://c:\documents and Settings\Daniel\Os meus documentos\humanoid\material_o...

Experiment 5. Strain Gage Measurements

2. Keyboard-An input device similar to a typewriter, for the entry of text, numbers and punctuation.

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

DVI KVM Switches DL-MUX 7.3

Force Measurement Systems. Force Measurement Systems

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

TEST CHAPTERS 1 & 2 OPERATING SYSTEMS

How to Install a Motherboard

PCI/PC Bus Operation ACR8020. ACR8020 Exclusives. ACR8020 (1- to 8-Axes) Ordering. 11 Parker Hannifin Corporation. Catalog 8180/USA Motion Controllers

Operator Touch Panel PC OTP/57V esom2586 / x86

Mobile Operating Systems Lesson 05 Windows CE Part 1

DiVAS video archiving and analysis software

Sun xvm VirtualBox Product Overview

US-SPI New generation of High performances Ultrasonic device

Type-D EEG System for Regular EEG Clinic

Mobile Mapping. VZ-400 Conversion to a Mobile Platform Guide. By: Joshua I France. Riegl USA

NGSS Data Consolidator (DC)

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

Solid as a Rock etop 300/400

miditech Audiolink II

VEHICLE DIAGNOSTICS THE AUTOCOM WAY

Network Video Recorder Quick Operation Guide

Matrix and Interfaces overview

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Transcription:

E.d.a.s.VX Data acquisition on board road and track vehicles The E.d.a.s.VX System is designed for portable applications running on 12 Volts DC, and is capable of measuring at selectable rates up to 30,000,000 samples per second. Manufactured with ruggedization in mind, for even the most demanding environments, this system includes an internal shock-mounted hard disk. For extremely employments it is possible to use flash disks for data storing. By providing several integrated interfaces, this system provides many opportunities for all portable applications and requirements. Modular design Different VX boxes can be used to combine a data acquisition system for your application. VX Computer Box The VX computer box includes all interfaces the user needs: - Keyboard / Mouse - CRT (Colour 1024 x 768) - LPT - COM - Fast Ethernet 10/100/1000 Mbit - 10 x USB High Speed - removable SATA Disk EdasVX_Eng.doc 10.02.20029 1/6

Seven build in USB high speed interfaces are use for connection of the VX data acquisition boxes. The sample clock of the data acquisition is simultaneous to every box. VX Analog Box One VX analog box has eight plug-in places for two channels full programmable or fixed wired amplifiers. Every analog channel has its own 16 bit analog to digital converter. The maximum sample rate is 40,000 samples per second for each analog channel. At the rear of the VX analog box an opto isolated full CAN interface can be used to collect up to 15 CAN signals. A connector for 16 opto isolated digital signals is available, too. - 16 analog signals, 16 bit resolution - 15 CAN signals - 16 digital inputs, opto isolated Every box send their signals using USB to the VX computer. VX Programmable Digital Interface Box This box will be programmed by MH to collect signals from a digital interface like wheel force systems, i. e. Up to 64 signals this special box sends to the VX computer. Three interfaces are available: - LT Caemax - RoaDyn90 - RoaDyn2000 VX Video Camera Up to four video camera cans be connected to the VX PC over USB. Up to 200 frames per second synchron to the measurement rate is possible. EdasVX_Eng.doc 10.02.20029 2/6

VX Seat Mounted Rack Using this rack the VX computer, a VX digital box and up to four VX analog boxes can be attach on a seat. With the seat belt the rack will be fixed. It is possible to use additional belts. With one full rack the following channels are available: - 64 analog channels - 60 CAN signals - 64 digital channels - 64 wheel force signals VX Input Modules & Signal Conditioning MH offers an entire line of Input Modules, manufactured utilizing advanced multi layer, surface mount technology, for virtually all active and passive transducers. Modules can be intermixed and scanned in any order and include features like programmable gains (up to 20,000), hardware selectable or computer controlled filtering (20 to 2,800 Hz, 1 Hz Step), integrated constant voltage signal conditioning, sensor excitation, and internal calibration facilities. All modules feature input protection and full isolation. EdasVX_Eng.doc 10.02.20029 3/6

MH - Gesellschaft für Sc hlos s Lec henic h D-50374 Erf tstadt T el.+49 2235/6095 inf o@mh-gmbh.de VX Mobile Monitor MH offers a monitor to visual the collecting signals during data acquisition. EdasVX_Eng.doc 10.02.20029 4/6

E.d.a.s.VX Software An extensive software comes with the E.d.a.s.VX computer to control all boxes and the data acquisition. A project and test management helps to navigate through all tests. An integrated signal and sensor database make it very easy to setup the test. All test and amplifier setup conditions are writing during data acquisition into the data files. During offline analysis the test and amplifier setup can be read. EdasVX_Eng.doc 10.02.20029 5/6

During data acquisition online selection for every signal. No limitation for the number of displaying signals. Possibility to load different displays online EdasVX_Eng.doc 10.02.20029 6/6