Mobile Mapping. VZ-400 Conversion to a Mobile Platform Guide. By: Joshua I France. Riegl USA
|
|
|
- Virgil French
- 10 years ago
- Views:
Transcription
1 Mobile Mapping VZ-400 Conversion to a Mobile Platform Guide By: Joshua I France Riegl USA
2 Table of Contents Introduction... 5 Installation Checklist... 5 Software Required... 5 Hardware Required... 5 Connections... 6 Communication Settings... 6 Hardware Connections Software Connections NMEA Messages Data Logging System Lever Arms Integration Settings RiAcquire Overview Acquiring Data Boresight Acquisition Checklist Summary References... 29
3 Figure 1: LV-POSView POS Internet Address window... 6 Figure 2: Network Sharing Center- Windows Figure 3: Local Area Connection Properties Window... 7 Figure 4: The active window is where the IP Address for the Laptop is to be changed... 8 Figure 5: GPS Connection Cable for the VZ Figure 6: VZ-400 interface connections Figure 7: GPS Sync. Cable to POS connections Figure 8: LV-POSView main window Figure 9: LV GPGGA message settings for Synchronization with the Scanner Figure 10: Logging output for Trajectory Processing Figure 11: IMU Reference to center label information Figure 12: VZ-400 Mobile mount configuration Figure 13: VZ-400 technical drawings Figure 14: Lever Arm and mounting information required for the system configuration Figure 15: System on a mobile surveying platform Figure 16: DMI mounting information window Figure 17: Opening window of Integration settings Figure 18: INS-GSP Settings Figure 19: INS-GPS Calibration table in the integration settings window Figure 20: Scanner Communication Settings Figure 21: Scanner Synchronization method selection Figure 22: Calibration Settings for the Scanner Figure 23: Scanner Project logging Settings Figure 24: Laser Configuration project settings
4 Figure 25: Configuration for the VZ Figure 26: License Manger inside of RiAcquire Figure 27: New Project screen in RiAcquire Figure 28: Scanner Settings Dialogue... 27
5 Introduction The VZ-400 is a fast and highly accurate tripod laser scanning solution. Its ability to synchronize with an external time source gives it a unique ability to also work in a mobile system. The mobile system configuration is described in detail for integration with an Applanix POS LV system. Most other navigation systems are able to be used with the VZ-400; please consult the RiAcquire Manual for specifications. Installation Checklist Software Required RiAcquire MLS RiProcesss SDCIMPORT RiWorld Trajectory Processing Software INS-GPS solution controller Hardware Required IMU GPS antennas and Receiver VZ-400 (or other Riegl scanner)* Data logging capabilities for IMU and GPS data Shock mount GPS-RS232 to BNC cable for PPS pulse and NMEA message Ethernet Cables (3) VZ-400 Ethernet cable with direct connection pigtail (only use cross over if directly communicating with laptop) Laptop Power cables Power source BNC antenna cables IMU cable Hub or switch for common data communication between instruments *Other requirements for Riegl LMS scanners that are not VZ-400 that exist; contact [email protected] ** The Applanix POS LV system is featured in this document. For a list of other INS-GPS solutions capable of use with Riegl LMS products, please consult the RiAcquire-MLS manual and [email protected]
6 Connections Using the correct cables to connect and communicate between the VZ-400 to an INS-GPS solution is the first step in the integration. Communication Settings Internet Protocol (IP) addresses of both the POS and the Scanner need to be in the same domain. A domain is the first six numbers of an IP address. The default IP address of a Riegl VZ-400 scanner is The default of IP of some POS systems is This IP address for the POS system can be easily changed using the LV (MV)-POSView program that comes with the Applanix POS system. The subnet mask must also be the same. The default setting for Riegl scanners is Some POS system may have the Subnet mask of as a default; this must be changed as well. Changing IP Address of the POS Connect to the POS Go to settings > Installation> POS IP Address Then, simply change the IP Address to the desired domain as shown in Figure 1, and click apply. Figure 1: LV-POSView POS Internet Address window *If not connected to the POS the change will not be implemented. Changing the Laptop Address In order to log into either the scanner or the POS with a different domain than the IP domain of the Laptop, one must change it to match the domain of the POS or the Scanner. Go to the control panel> Networking and Sharing Center (Figure 2). Click local area connection > Properties (Figure 3).
7 Select Internet Protocol Version 4 (TCP/IPV4) > Properties (Figure 4). Adjust IP address and Subnet mask to match the POS or VZ-400. Figure 2: Network Sharing Center- Windows 7 Figure 3: Local Area Connection Properties Window
8 Figure 4: The active window is where the IP Address for the Laptop is to be changed
9 Changing the VZ-400 s IP address Use the HMI to change the VZ-400 s IP address. Project Setup Menu 3.1 LAN & WLAN LAN & WLAN menu To configure the LAN & WLAN: At project setup menu, use Cursor Key up / down to highlight LAN & WLAN then press Enter Key. The image above shows the LAN & WLAN menu. From project setup menu, use Cursor Key up / down to highlight LAN & WLAN then press Enter Key. The image above is the page after project setup menu. To select from LAN0 (100 MBit), WLAN, and
10 LAN0 (1GB), use Cursor Key up / down to highlight page x/3, < > changes then use Cursor Key left / right to change communication type. To change configuration for each communication type, use Cursor Key up / down to highlight then press Enter Key. Then use Cursor Key left / right to change configuration type. When desired configuration is selected, press Enter Key to save and exit option. To change the IP address, IP subnet mask and IP gateway, follow steps previously described in this paragraph. Once all systems are on the same internet, domain integration can begin. Hardware Connections The VZ-400 comes with a GPS Interface Cable, Figure 5, with a BNC connector for the PPS pulse and a serial connector for the POS NMEA message. This is connected on the scanner via the trigger socket, see Figure 6. Figure 5: GPS Connection Cable for the VZ-400
11 Figure 6: VZ-400 interface connections The GPS connection cable is then connected to the POS COM port(s) and to the PPS OUT, BNC connector, Figure 7. Figure 7: GPS Sync. Cable to POS connections The TCP/IP cable from the scanner and the POS should be connected to a hub and then connected to a laptop or acquisition computer. This completes the hardware connections of the scanner to the POS. The POS should be connected to the IMU and to the GNSS antenna(s) before starting the system.
12 Software Connections LV-POSView NMEA Messages Two NMEA messages are recommended as the best to use for this system. The first for POSLV s is the GPGGA message and for POSMV s, the only message is GPZDA. The GPZDA will work for both LV and MV units. To make these message selections, connect to the POS using the POS controller software, Figure 8. Figure 8: LV-POSView main window Then, go to Settings > Input/Output Ports. Then, select the correct com port tab that corresponds to the com port the scanner GPS cable is connected to. In this case, it is com port 1. Select the desired message and the talk ID and an Update rate of 1 HZ. Also, select a Baud rate for the com port use 9600.
13 Figure 9: LV GPGGA message settings for Synchronization with the Scanner Data Logging Click Apply then close. Next, go to Logging > Ethernet logging. Select POSPac. Then, check box 3- Primary GPS Data, as shown in Figure 10: Logging output for Trajectory Processing, Figure 10. Figure 10: Logging output for Trajectory Processing Do the same for PC Card Logging to create a backup trajectory.
14 System Lever Arms The reference point for this system integration will be the top of the IMU at the center mark. Four main lever arm measurements are required for accurate trajectory data for LiDAR processing. The first is for the offset between the top label of the IMU and the actual IMU reference point. This should be listed in a manual or listed on the label, Figure 11. Figure 11: IMU Reference to center label information The next lever arm is to determine the distance from the center of the IMU to the primary GPS antenna. This measurement should be within 3 centimeters. The higher the accuracy, the better the GAMS solution will be and the quicker it will be calculated. The next lever arm to be measured is the distance to the VZ-400 reference point from the IMU Reference point, Figure 12 and Figure 13.
15 Figure 12: VZ-400 Mobile mount configuration Figure 13: VZ-400 technical drawings
16 Figure 14: Lever Arm and mounting information required for the system configuration Entering the Lever Arms Settings> Lever Arms & Mounting Angles There are 2 initial distance measurements that need to be made and then entered into their corresponding sections: one from the IMU reference to the primary GPS antenna and one from the IMU reference to the top of the IMU. Remember that the origin of the system is the IMU reference with X-axis forward. Due to the way this system mounts, a 180 rotation about the X axis needs to be entered in the IMU Frame with respect to the Reference Frame section. The Reference Frame is the vehicles with X being forward motion, Y being to the right or starboard side, and Z being down. DMI The final lever arm measurement is from the bottom of the driver s side rear tire to the reference point. This 3 dimensional measurement is best measured with 3D scan from 2 or more scan positions using the VZ-400. This will allow for a measurement of around 3 cm or better accuracy. The other measurement that is needed is the circumference of the wheel. This number is used for the DMI scale factor calculation, Equation 1.
17 Figure 15: System on a mobile surveying platform Equation 1: DMI Scale factor d Diameter of the wheel C Circumference of the wheel This information is entered on the sensor mounting tab of Lever Arms and Mounting Angles window, Figure 16. Figure 16: DMI mounting information window
18 RiAcquire Integration Settings Open RiAcquire and then go to System > Integration Settings. Figure 17: Opening window of Integration settings Then, add both a scanner and INS-GPS using the plus button and select the type and enter the proper serial number. IMPORTANT! An S must be added before the scanner Serial number! Next, select the connect type for the INS-GPS 1 of TCP/IPv4 and then enter the IP Address, Figure 18. Then, check the calibration tab to make sure the axes are north, east and down, Figure 19. The matrix IMU to Body is left as an identity matrix because the trajectory software will handle the rotation of the IMU to the Body frame.
19 Figure 18: INS-GSP Settings Figure 19: INS-GPS Calibration table in the integration settings window
20 Select Scanner 1 and enter the correct IP Address for the scanner. Then, go to the synchronization tab and select External GPS RS232 for the Used Synchronization Method. Set the time Tag Data String Format to GPGPPA, unless using a POS MV system; then use GPZDA. For all Applanix POS systems, it s Data First. POS LV is Positive PPS Trigger Edge and POS MV is Negative Trigger Edge. Finally, select the correct GPS RS232 settings that match the settings in LV-POSview, Figure 9. The settings selected should be similar to Figure 21. Figure 20: Scanner Communication Settings
21 Figure 21: Scanner Synchronization method selection All default settings in Scan Synchronization and Options tabs are left alone. The final settings need to be entered under the calibration tab, Figure 21. The rotational matrix is used to align the scanner s own coordinate system with the IMU s coordinate system. Both coordinate frames follow the right hand rule. Use Figure 13 for understanding of the Scanner s reference frame. The IMU has been rotated but we have corrected this rotation with LV-POSView, Figure 14. Therefore, the IMU s frame is in line with the vehicle s reference frame NED.
22 Figure 22: Calibration Settings for the Scanner This completes the integration settings needed in RiAcquire. Test the connects with the connection test. If the systems are properly connected, it will show 2 green check marks. Then, click ok and use the password ican, it is not case sensitive.
23 RiAcquire Overview Environment Settings Next, go to environment settings. Here all display, unit, and project defaults can be altered and set. The main settings to adjust will be presented. Under project select the scanner tab and switch the Logging Method from Single File to Multiple Files, Figure 22. Figure 23: Scanner Project logging Settings The next feature to prepare ahead of an acquisition mission is the Laser Configuration. Go to the Laser Configuration tab under the Project menu. Here, add as many possible look directions as needed to complete the boresight or mission, Figure 24. To add a new configuration, click the plus button then highlight the new configuration and click the pencil button. This opens the configuration window, Figure 25. The target distance and ground speed numbers are just for parameter calculation and do not have to be adjusted for every mission. Set Scan Mode to Line, set Measurement Program to High Speed Mode, and set Frame Start to the desired orientation.
24 Figure 24: Laser Configuration project settings.
25 Figure 25: Configuration for the VZ-400 License Manager Each Scanner has a unique license code for data acquisition that does not require a dongle. It must be entered into the license manager before scan data acquisition is allowed. Go to System > License Manger and then click import and select the *.lic file provided with the system documentation, Figure 26 or click in the white space and type the 32 character license code for RiAcquire.
26 Figure 26: License Manger inside of RiAcquire Acquiring Data Create a new project in RiAcquire, Figure 27. Then, click the green star button to initialize all instruments, scanner and INS-GPS. The scanner settings window will pop up. Select the laser configuration desired; also enter the atmospheric parameters, Figure 28. Click the globe with the green dot to start the 5 minute countdown for the INS-GPS static session. Once finished, start the scanner with the scanner icon and green dot; then start logging with a pencil, the scanner icon and green dot. Similar icons with red dots stop logging and stop the scanner. The scanner must be stopped in order to change configuration settings. Figure 27: New Project screen in RiAcquire
27 Figure 28: Scanner Settings Dialogue
28 Boresight Acquisition Checklist 1. Select a target rich environment with a good sky view 2. Make repeated passes over the same target area at difference angles a. Depending on orientation, at least 8 different angles. b. With 0 being forward the follow combination would work i. 30, 60, 90, 120, 150 ii. 330,300, 270, 240, Integration setting between the POS and Scanner a. IP addresses and NMEA message 4. Lever arm measurements (Note must be connected to POS for changes to stick) a. Make top of IMU Ref point b. Rotate POS frame to match North, EAST, Down c. DMI Scale factor must be correct d. REF to GPS 1 e. REF to GPS 2 f. REF to DMI g. Times set to UTC time 5. GAMS measurement of antenna separation 6. Start base station data logging 7. GAMS calibration procedures 8. Static Session for 5 minutes 9. Initialization of RPY values 10. Collect scan data at all preset angle values 11. End with 5 minute static session
29 Summary Mobile scanning systems have a wide range of use and in conjunction with tripod scanning will provide excellent data for feature extraction. The VZ-400 mobile system is seen as a system to fill the gap between fully integrated mobile mapping systems such as the VMX-250 and tripod scanning on a mobile lift, i.e. TopoLift. While this manual describes in detail how to integrate a VZ-400, it can also be used for integration of any Riegl scanner with the proper sync timer functions and hardware. References 1. Rieger,P., Studnicka, N., and Pfennigbauer, M. Boresight Alignment Method for Mobile Laser Scanning Systems. RSPRS. Moscow, Russia. December < 2. Applanix A Trimble Company. POS LV4 Installation and Operation Guide, June, Applanix A Trimble Company. POS MV V4 User Guide, May, Riegl Laser Measurement Systems GmbH. 3D Terrestrial Laser Scanner Riegl VZ-400/ Riegl VZ Horn, Austria. October 10, Riegl Laser Measurement Systems GmbH. RiAcquire-MLS. Horn, Austria. March 2011.
CHAPTER 2: USING THE CAMERA WITH THE APP
TABLE OF CONTENTS OVERVIEW... 1 Front of your camera... 1 Back of your camera... 2 ACCESSORIES... 3 CHAPTER 1: Navigating the Mobile Application... 4 Device List: How to Use this Page... 4 My Messages:
SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9
SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9 Learning Goals: At the end of this lab, the student should have basic familiarity with the DataMan
Recommended Network Setup
Recommended Network Setup Greater Giving Event Software uses Windows File Sharing to allow multiple computers to connect to the same database within your network. This document uses Windows XP as the default
Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel +32 16 317 411 Fax +32 16 207 164 http://www.option.com Page 1 of 14
Page 1 of 14 ! " #!"#$ % &&' Page 2 of 14 1 INTRODUCTION One of the highly desirable features of the GlobeSurfer III device is the ability to network together Printers and External Hard Disk drives (aka
Configuring a Trimble Sps 461 using the Ethernet Connection GETTING THE GPS ON THE NETWORK HTTP PORT. By Bob Glover
Configuring a Trimble Sps 461 using the Ethernet Connection By Bob Glover With most computers today, finding a serial port on board is a thing of the past. Increasingly, fewer and fewer computers even
Basic Configuration Package
Basic Configuration Package Scanner Basic Configuration for Part-No. HW-Z210-01-001-02 3D Laser Scanner LMS-Z210ii-S (Part-No. HW-Z210-00-001-02) - Laser transmitter & receiver front end - Motorized mirror
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.
DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS REV 04.11 LOCAL AREA NETWORK (LAN) CONNECTION Ethernet Connection: An Ethernet Cable, or wireless connection must
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
Ethernet Interface Manual Thermal / Label Printer. Rev. 1.01 Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2
Ethernet Interface Manual Thermal / Label Printer Rev. 1.01 Metapace T-1 Metapace T-2 Metapace L-1 Metapace L-2 Table of contents 1. Interface setting Guiding...3 2. Manual Information...4 3. Interface
CMP-102U. Quick Installation Guide
CMP-102U Quick Installation Guide V1.0 http://www.cnet.com.tw 1 CMP-102U Supports One High-speed USB2.0 Port MFP Server Supports 10/100Mbps Fast Ethernet Network Quick Installation Guide 1 Package Contents:
EnGenius ERB9250 300M Range Extender. Quick Start Guide
EnGenius ERB9250 300M Range Extender Quick Start Guide Package Contents One ERB9250 300M Range Extender One 12V/1A power adapter Two 2dBi 2.4GHz SMA antennas One Ethernet cable One CD-ROM with user s manual
SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0
SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0 Before You Begin Before you install the SOHO 6 Wireless, you must have: A computer with a 10/100BaseT Ethernet card
P-2024. Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address http://192.168.5.1 Password 1234. Version 3.60 7/2007 Edition 1
P-2024 VoIP Analog Telephone Adaptor Quick Start Guide Version 3.60 7/2007 Edition 1 DEFAULT LOGIN IP Address http://192.168.5.1 Password 1234 Copyright 2007. All rights reserved. Overview Use your P-2024
1. Hardware Installation
4 Port 10/100M Internet Broadband Router with USB Printer server Quick Installation Guide #4824904AXZZ0 1. Hardware Installation A. System Requirement Before you getting started, make sure that you meet
Crow Limited Warranty. Print Version 017
Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose
MANUAL Device Type Manager
FACTORY AUTOMATION MANUAL Device Type Manager 2D Laser Scanner OBD10M-R2000-4EP-V1V17 With regard to the supply of products, the current issue of the following document is applicable: The General Terms
NetLINE Wireless Broadband Gateway
NetLINE Setup Guide Farallon s NetLINE connects to your cable/dsl modem, allowing computers on your local wired and wireless networks to share a single broadband connection to the Internet. This Setup
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
1 INTRODUCTION. This document describes the procedure to upgrade LTMR.
1 INTRODUCTION This document describes the procedure to upgrade LTMR. Limitation: this package and procedure describe only the upgrade of the LTMR firmware for all network versions (Modbus, Profibus, DeviceNet,
SATO Network Interface Card Configuration Instructions
SATO Network Interface Card Configuration Instructions Table of Contents 1. Reset of wired/wireless interface card... 3 2. Installing the All-In-One Utility (recommended)... 4 3. Configuring wired/wireless
Interfacing Basler GigE Cameras With Cognex VisionPro 7.2
www.baslerweb.com Interfacing Basler GigE Cameras With Cognex VisionPro 7.2 This Application Note explains how to interface a Basler camera with GigE interface with the Cognex VisionPro 7.2 software package
UPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
Application & Quick-Start Guide
Model: CRMWIC Web Intelligent Controller 1 This document will illustrate various ways to connect and use a CRM-WIC as well as programming examples. When connecting CRM-WIC, the installer has several interface
SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
E-Mon Communication Gateway Utility Instructions for BACnet/mstp
E-Mon Communication Gateway Utility Instructions for BACnet/mstp The E-Mon Communication Gateway utility will allow you to configure the Device Instance (Node ID) and other parameters needed for your BACnet/mstp
Volume. Instruction Manual
Volume 1 Instruction Manual Networking EVERFOCUS ELECTRONICS CORPORATION Networking Instruction Guide 2004 Everfocus Electronics Corp 2445 Huntington Drive Phone 626.844.8888 Fax 626.844.8838 All rights
Section 5: Connecting the Laser to Your Computer
Section 5: Connecting the Laser to Your Computer In This Section Connecting the Laser to your Computer USB Port Ethernet Port Connecting the Laser to Your Computer All Epilog systems are designed to be
IntraVUE Plug Scanner/Recorder Installation and Start-Up
IntraVUE Plug Scanner/Recorder Installation and Start-Up The IntraVUE Plug is a complete IntraVUE Hardware/Software solution that can plug directly into any network to continually scan and record details
EASE Scan Tool Customers. SECTION I - Installation
Please Install Your EASE Scan Tool DVD Before Installing Any Other Software That Came With Your Package. SECTION I - Installation ATTENTION: Do NOT connect an EASE Vehicle Interface Device to your Computer
Application Note: Connecting to a 2500 Series Processor using PLC Workshop
Application Note: Connecting to a 2500 Series Processor using PLC Workshop This application note will describe a step by step process for the three ways to connect to a 2500-CXXX with PLC Workshop. The
PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications
PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications PC/POLL SYSTEMS supports native TCP/IP polling for the SPS2000 cash register. It is recommended users have the register updated
Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements
Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements - Two (2) MiCOM Px4x IEDs with Version 2 implementation of IEC 61850 - Two (2) Cat 5E Ethernet cable - An Ethernet switch 10/100 Mbps - MiCOM
Setting Up Internet Connection Sharing (ICS) on a Server
Setting Up Internet Connection Sharing (ICS) on a Server May 8, 2012 Copyright 2012 by World Class CAD, LLC. All Rights Reserved. Two NICs in the Device Manager We need to install the second NIC if we
How To Connect A300 To A300 Time Clock On A Pc Or Mac Computer
1 TABLE OF CONTENTS INTRODUCTION CHAPTER 1 ESTABLISHING A CONNECTION TO TIME CLOCK 1.1 INSTALLATION OF SOFTWARE 1.2 CONNECT TIME CLOCK TO PC 2 1.2.A..VIA USB CABLE CONNECTION 2-5 1.2.B... VIA TCP/IP NETWORK
Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012
Quick Note 32 Using Digi RealPort with a Digi TransPort Router UK Support September 2012 1 Contents 1 Introduction... 3 1.1 Outline... 3 1.2 Assumptions... 3 1.3 Version... 3 2 Configuration & scenario...
Brady IP Printer Installation Instructions
Brady IP Printer Installation Instructions Ensure the following are available before commencing installation: The IP Printer and accessories (Printer, power cable, Product CD including Windows printer
2 Setting Up the Hardware for a Wired Ethernet Network... 13. 3 Setting Up the Software for an Ethernet Network... 21
Contents 1 Networking Basics............................................... 1 Selecting a network connection........................................ 2 Wired Ethernet network...........................................
1 Synchronising Xsens Systems with Noraxon TeleMyo
1 Synchronising Xsens Systems with Noraxon TeleMyo The steps described below show how to make it possible for Xsens Awinda or Sync Station to send a signal (Awinda / Sync Station is Sync OUT and Noraxon
RIEGL SYSTEM CONFIGURATION 3D TERRESTRIAL SCANNER LMS-Z390
Holder for GPS antenna, detachable, for Nikon D70s / Nikon D100 / Nikon D200 camera mount Part-No. 02RA09-00-009-00 or for Canon EOS 1Ds Mark II camera mount Part-No. 02RA09-00-011-00 or for Canon EOS
Stand Alone Type. Digital Video Recorder USER S MANUAL. (Real time recording 8 & 16 CH DVR) Revision Date : 2010. 6. 30.
Stand Alone Type Digital Video Recorder USER S MANUAL (Real time recording 8 & 16 CH DVR) Revision Date : 2010. 6. 30. INDEX 1. Front Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide
Prestige 324 Intelligent Broadband Sharing Gateway Version 3.60 January 2003 Quick Start Guide 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100 Mbps
Connecting the DG-102S VoIP Gateway to your network
Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information
Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide
Prestige 324 Intelligent Broadband Sharing Gateway Version V3.61(JF.0) May 2004 Quick Start Guide 1 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100
Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005
Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)
Manual Wireless Extender Setup Instructions. Before you start, there are two things you will need. 1. Laptop computer 2. Router s security key
1 Manual Wireless Extender Setup Instructions Before you start, there are two things you will need. 1. Laptop computer 2. Router s security key Setting up LAN Static IP on PC We need to set up a Static
Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)
Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
3.5 EXTERNAL NETWORK HDD. User s Manual
3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility
Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.
Dexter is a network device using the Ethernet protocol to connect and communicate with other devices on the network: Computers, routers, DHCP servers. Thus you have to setup your Dexter and your network
Deploying Windows Streaming Media Servers NLB Cluster and metasan
Deploying Windows Streaming Media Servers NLB Cluster and metasan Introduction...................................................... 2 Objectives.......................................................
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)
UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY) Hardware Installation 1. Initial placement for programming and configuration purposes should be performed in an indoor environment.
DS2X00N-DS4800 SCANNER FAMILY
DS2X00N-DS4800 SCANNER FAMILY SETUP PROCEDURE USING PROGRAMMING BARCODES 1 ID-NET NETWORK SETUP USING PROGRAMMING BARCODES For any DS2x00N-DS4800 Family scanner, programming barcodes can be used to setup
Network Setup Guide. 1 Glossary. 2 Operation. 1.1 Static IP. 1.2 Point-to-Point Protocol over Ethernet (PPPoE)
Network Setup Guide 1 Glossary 1.1 Static IP Computers are communicated and recognized by their own unique IP addresses over the Internet. Static IP provided by your ISP (Internet Service Provider) means
BASLER ACE QUICK INSTALLATION GUIDE
BASLER ACE QUICK INSTALLATION GUIDE Rev. 01 Quick installation Guide V1 1 Introduction The installation procedures in this guide assume that you want to get your camera operational and begin capturing
GPS NTP Time Server for Intranet Networks DIN RAIL Version
GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with
LOAD BALANCING 2X APPLICATIONSERVER XG SECURE CLIENT GATEWAYS THROUGH MICROSOFT NETWORK LOAD BALANCING
SECURE CLIENT GATEWAYS THROUGH MICROSOFT NETWORK LOAD BALANCING Contents Introduction... 3 Network Diagram... 3 Installing NLB... 3-4 Configuring NLB... 4-8 Configuring 2X Secure Client Gateway... 9 About
Contents. Section A Networking Basics... 1. 1 Learning the Basics... 3. Section B Wired Ethernet Networking... 17
Contents Section A Networking Basics...................................... 1 1 Learning the Basics............................................. 3 Selecting a network connection........................................
Chapter 1 Installing the Gateway
Chapter 1 Installing the Gateway This chapter describes how to set up the wireless voice gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration. For information
CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs
CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs Tasks: 1 (10 min) Verify that TCP/IP is installed on each of the computers 2 (10 min) Connect the computers together via a switch 3 (10 min)
How To Set Up Flir Cloud Client For Pc Or Mac Or Mac (For Pc Or Ipad) On A Pc Or Pc Or Mouse (For Mac) On An Iphone Or Ipa) On Pc Or Tv (For Ipa
Instruction Manual FLIR Cloud Services Client Instruction Manual FLIR Cloud Services Client #LX400018; r. 2.0/14567/14568; en-us iii Table of contents 1 Setting up FLIR Cloud Client for PC or Mac...1
AEI RAIL NETWORK SERVER User Manual
AEI RAIL NETWORK SERVER User Manual Copyright 2000 Signal Computer Consultants All rights reserved Signal Computer Consultants P.O. Box 18445 Pittsburgh, PA 15236 Tel. 888 872-4612 (toll free US and Canada
OfficeConnect Internet Firewall 25 Internet Firewall DMZ. QuickStart Guide (3C16770, 3C16771)
OfficeConnect Internet Firewall 25 Internet Firewall DMZ QuickStart Guide (3C16770, 3C16771) Checking Package Contents Getting Started Thank you for purchasing the OfficeConnect Internet Firewall. The
Installation and Operation Guide
www.aja.com Quick Start Guide Introduction This Quick Start Guide provides a basic overview of KUMO configuration. It is not meant as a substitute for the detailed information found in the KUMO Manual,
Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11
Servicom G.R.I.P. Enabling Global Push-to-Talk over BGAN and Fleet Broadband Version 01 30.09.11 Contents 1 Overview... 1 2 Background... 1 3 Key Features... 2 4 Typical Users... 2 5 Benefits to BGAN and
Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.
TA Instruments TRIOS Software Installation Instructions Installation Requirements Your TRIOS Instrument Control software includes all the components necessary to install or update the TRIOS software, as
Before You Begin You must have at least the following: Web Browser Wired Hub/Switch/Router OR Wireless 802.11b Router CD-ROM Drive
This product can be set up using any current Web browser, i.e., Internet Explorer 6.0 or Netscape Navigator 7.0 DCS-1000W D-Link 2.4Ghz Wireless Internet Camera Before You Begin You must have at least
ReadMe File. Installing the Unified Messaging Application for
ReadMe File MERLIN! Messaging System Release 4.0 and PARTNER! Messaging System Release 7.0 Installing the Unified Messaging Application 11-300139, Issue 2, May 2004 ReadMe File Installing the Unified Messaging
Professional Surveillance System User s Manual
Professional Surveillance System User s Manual \ 1 Content Welcome...4 1 Feature...5 2 Installation...6 2.1 Environment...6 2.2 Installation...6 2.3 Un-installation...8 3 Main Window...9 3.1 Interface...9
Voice Over Internet Protocol (VoIP) Configuration
(VoIP) Configuration ENGINEERING REPORT No: 02-003 Introduction This report describes interfacing the IPCS VoIP Gateway Model EGW-902 to an ESTeem Model 192E Wireless Ethernet radio modem in a demonstration
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
FLIR M-Series and NavNet TZtouch
FLIR M-Series and NavNet TZtouch Overview The following example illustrates the integration of the FLIR M-Series into a NavNet network. The M- Series and the JCU controller are set with a fix IP address
Quick Instructions for Setting up Swe-dish.
Quick Instructions for Setting up Swe-dish. Physical Set-up. 1. Pick a location with a hard mainly level surface (feet on bottom of suitcase are adjustable if surface is uneven). 2. Align the Suitcase
CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00
CX Series Video Recording Server CX784 / CX788 / CX7816 Quick Start Guide Version 1.05.00 Contents 1.Introduction...1 1.1.Packages Contents...1 1.2.Hardware Features...2 1.3.Functional Features...4 1.4.Hard
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start
mysensors Information to Users mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant
VinNOW-TSYS Integration Setup
VinNOW-TSYS Integration Setup Once your account is established with TSYS, and installation appoint should have been arranged. If not, contact your sales representative as these steps should be done for
Technical Note. Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch. Contents
Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch Contents 1. Introduction...2 2. Equipment...2 3. Software...3 4. Definitions...3 5. Procedure...3 6. Change PC IP Address...3 7. Network
LPT1 Printer Connector. External Power Supply Connector Power Indicator
AXIS 1650 Set-up Instructions Page 3 Unpack box Verify that you have all the items listed below: LPT1 Printer Connector Network Indicator Ethernet Connector External Power Supply Connector Power Indicator
Network Setup & Options
3.0 Network Setup & Options 3.3 TABLE OF CONTENTS 3.1 INTRODUCTION... 5 3.2 DISABLING NETWORK SECURITY SETTINGS... 6 3.2.1 Aftermarket Internet Security and Firewalls... 6 3.2.2 Windows Firewall... 6
EDGE FX Network configuration
Page 1 of 16 TITLE: Category: EDGE FX Network configuration GERBER EDGE Document Number: 4280 Supplied by: Gerber Service Last Modified: April 14, 2011 Summary: In order to connect an EDGE FX to your PC
USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6
KRAMER ELECTRONICS LTD. USER GUIDE Ethernet Configuration Guide (Lantronix) P/N: 2900-300321 Rev 6 Contents 1 Connecting to the Kramer Device via the Ethernet Port 1 1.1 Connecting the Ethernet Port Directly
User Manual Network Interface
User Manual Network Interface Rev. 1.00 SRP-350plusll SRP-352plusll http://www.bixolon.com Table of Contents 1. Manual Information...3 2. Specifications...3 2-1 Hardware version...3 2-2 Configuration Tool...3
RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website www.riegl.com
Airborne Laser Scanner with Online Waveform Processing RIEGL VQ-48 high-accuracy ranging based on echo digitization and online waveform processing high laser repetition rate - fast data acquisition multiple
AXIS Camera Companion Internet access
AXIS Camera Companion AXIS Camera Companion Internet access AXIS Camera Companion 2.0 introduces a new way to access sites and cameras remotely. When installing AXIS Camera Companion on a PC with internet
OSM 2007 MONITORING SOFTWARE
OSM 2007 MONITORING SOFTWARE Contents Preparation...3 Software Installation...4 Configuring OSM...6 Connecting a Device...16 Connecting to Station Monitoring Software...19 Troubleshooting...23 Installing
CRE Monitor Instructions Manual
CRE Monitor Instructions Manual CRE TECHNOLOGY believes that all information provided herein is correct and reliable and reserves the right to update at anytime. CRE TECHNOLOGY does not assume any responsibility
TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer
i-stat TECHNICAL BULLETIN Configuring Wireless Settings in an i-stat 1 Wireless Analyzer Before configuring wireless settings, please enable the wireless functionality by referring to the Technical Bulletin
Configuring an A Series LED Sign Controller for your Network
Configuring an A Series LED Sign Controller for your Network A Series LED displays from Optec support both serial and 10BaseT Ethernet communication. Serial communication via RS232 or RS485 is independent
User s Manual for Fingerprint Door Control Software
User s Manual for Fingerprint Door Control Software Foreword The naissance of F7 indicated that fingerprint reader enters into professional door control domain. That s why we developed this software to
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
Centurion PLUS CPC4 Download Guide
Centurion PLUS CPC4 Download Guide using C4 File Transfer Utility. 1010537 03 01 10 Section 50 1.0 Background: 1.1 The Centurion PLUS Control system consists of a Centurion PLUS Core (CPC4 1) and Color
NTP Receiver/Software Installation Guide
NTP Receiver/Software Installation Guide 11869 Teale St. Culver City, CA 90230 Tech Support: 888-608-0125 www.innovationwireless.com Table of Contents Important Note... 3 Software Installation... 4 DHCP
V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).
V.I.P. Kit (Video Insight Pilot Kit). Video Insight Pilot Kit Please follow these instructions and everything should go very smoothly. Before you begin, you will need to establish (or obtain from your
NVMS-1200. User Manual
NVMS-1200 User Manual Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Install and Uninstall... 1 1.2.1 Install the Software... 1 2 Login Software... 3 2.1 Login... 3 2.2 Control Panel Instruction...
Please use only wired network connections to configure the router.
Note Please use only wired network connections to configure the router. Connect the WAN port on your Router to the Modem s LAN port with an Ethernet cable. Note If connecting the TL-WR543G to the WISP
Internet for Everyone In-Room Instructions January 2011 Version 1.3
Internet for Everyone In-Room Instructions January 2011 Version 1.3 Everywhere Internet 2006 Page 1 of 17 Connecting your computer to the Everywhere Internet network in your room 1. You need a network
Configuring the FAR2XX7 Series Radar for use with MaxSea Time Zero
Configuring the FAR2XX7 Series Radar for use with MaxSea Time Zero Introduction In order to operate with MaxSea Time Zero AND NavNet3D, the FAR2XX7 s processor software must be version 02.5x. If you plan
EPSON Scan Server & EPSON TWAIN Pro Network
EPSON Scan Server & EPSON TWAIN Pro Network EPSON Scan Server & EPSON TWAIN Pro Network SCANNER UTILITY PROGRAMS All rights reserved. No part of this publication may be reproduced, stored in a retrieval
