RY2 miniature industrial relays



Similar documents
pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

60 Series - General purpose relays 6-10 A. Features

49 Series - Relay interface modules A. Features

40 Series - Miniature PCB/Plug-in relays A. Features

48 SERIES Relay interface modules 10 A

38 Series - Relay interface modules A

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

38 Series - Relay interface modules A

Pluggable interface relays CR-P Pcb relays

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

Elesta Elektrotechnik AG industry relays and accessories

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

RM4TG20 three-phase network control relay RM4-T - range V

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

SKR - industry relay

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Goodsky Technical Data. Contact Details

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

FP2 Relay. The Best Relaytion

AZ420 MINIATURE GENERAL PURPOSE RELAY

Model Number Structure

Solid-State Timer H3G

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Model Number Structure

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Signal Relays AXICOM. P2 Relay V AXICOM Telecom-, Signal and RF Relays. P2 V23079 Relay. Coil Operating Range. Coil Data

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Cable Plug acc. to DIN EN , Form A

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Telemecanique Zelio Relay complementary and easy to assemble

SPST-NO SPDT DPST-NO DPDT

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

HERZ-Thermal Actuators

1 POLE - 5A SLIM POWER RELAY

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

13 SERIES. Electronic step relays A

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

Inductive sensor NI10-M18-Y1X-H1141

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

R.C.C.B. s two-pole LEXIC

Three-phase monitoring relay CM-PFE

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

80 Series - Modular timers 16 A. Features

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Electronic overload relay EF19 and EF45

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

General Purpose Relays Accessories. Accessories Miniature Relay PT

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Contact expansion modules

General-purpose Relay

Safety technique. Emergency stop module BO 5988 safemaster

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Emergency lighting units EM powerled

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

1 POLE - 8A Medium Load Control

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic overload relay EF65, EF96 and EF146

DS 600. A contact free flux gate based current measurement sensor 600A rms

Fast, reliable, ultra-precise. My-Com precision switches.

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Panel Meters and Controllers Modular Panel Meter Type EDM 35

12 Series - Time switches 16 A. Features

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Inductive Proximity Sensors

Contact expander modules

E-STOP relays, safety gate monitors

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Relés e Contatores de Estado Sólido SIRIUS

Transcription:

6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS, Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Contact resistance Max. operating frequency at rated load no load Coil data Must release voltage Operating range of supply voltage Rated power consumption Insulation according to PN-EN 60664-1 Insulation rated voltage Rated surge voltage Overvoltage category Insulation pollution degree Dielectric strength between coil and contacts contact clearance pole - pole Contact - coil distance clearance creepage General data Operating / release time (typical values) Electrical life resistive cosφ Mechanical life (cycles) Dimensions (L x W x H) Weight Ambient temperature Cover protection category Shock resistance Vibration resistance AC DC1 50/60 Hz AC DC AC DC storage operating 2 C/O AgNi, AgCdO 250 V / 440 V 5 V AgNi, 10 V AgCdO A / 250 V AC A / 30 V DC 5 ma AgNi, 10 ma AgCdO 20 A A 3 000 VA 0,3 W AgNi, 1 W AgCdO 100 mω 1 200 cycles/hour 18 000 cycles/hour 6...0 V 5...0 V AC: 0,2 U n DC: 0,1 U n see Tables 1, 2 1,6 VA 0,9 W 250 V AC 4 000 V 1,2 / 50 µs III 3 2 500 V AC type of insulation: basic 1 000 V AC type of clearance: micro-disconnection 2 500 V AC type of insulation: basic 2,6 mm 4 mm 15 ms / 10 ms 10 5 A, 250 V AC see Fig. 2 10 7 27,5 x 21,1 x 34,5 mm ❶ 35 g -40...+70 o C -40...+55 o C IP 40 PN-EN 60529 10 g 5 g 15...150 Hz The data in bold type pertain to the standard versions of the relays. ❶ For plug-in sockets version: standard

RY2 7 Coil data - DC voltage version Table 1 VDC Coil resistance ±10% at 20 C min. (at 20 C) Coil operating range VDC max. (at 55 C) 1005 1006 10 10 1048 1060 1080 1110 15 20 5 6 48 60 80 110 5 0 28 40 160 640 2 600 4 000 7 100 13 600 16 000 54 000 4,0 9,6 19,2 38,4 48,0 64,0 100,0 176,0 5,5 6,6 13,2 26,4 52,8 66,0 1,0 137,5 2,0 Coil data - AC 50/60 Hz voltage version Table 2 VAC Coil resistance ±10% at 20 C min. (at 20 C) Coil operating range VAC max. (at 55 C) 5006 50 50 5042 5048 5060 5080 5110 50 57 50 5230 50 6 42 48 60 80 110 0 7 0 230 0 9,8 39,5 158,0 470,0 640,0 930,0 1 720,0 3 450,0 3 770,0 4 000,0 15 400,0 16 100,0 16 800,0 9,6 19,2 33,6 38,4 48,0 64,0 96,0 101,6 176,0 184,0 192,0 6,6 13,2 26,4 46,2 52,8 66,0 1,0 132,0 139,7 2,0 253,0 264,0

8 RY2 Dimensions - plug-in version (standard) Dimensions - version with mounting flange in the upper wall of the cover 4 4,7 5,9 7,25 4 4,7 5,9 7,25 10 14,2 10 8 3,5 14,2 27,5 21,1 38 43 28,4 3 34,5 34,5 6,4 6,4 0,5 0,5 Electrical life at AC resistive load. Maximum switching frequency at rated load Fig. 1 Electrical life reduction factor at AC inductive load Fig. 2 N Number of cycles Reduction factor Power factor Breaking capacity [kva] Connection diagram (pin side view) (1) 42 (2) 14 (3) 11 (5) 44 (4) 41 (6) + A1 (7) - A2 (8) 2 C/O Note: marks + and - refer to versions with DC coils, with surge suppresion element (diode) and light indicator (LED diode).

RY2 9 Mounting Relays RY2 are offered in versions: standard, for plug-in sockets with mounting flange in the upper wall of the cover. Relays RY2 are designed for: screw terminals plug-in sockets GZY2 with clip GZY 2000 and spring clamp GZ2 1111, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting with two M3 screws flat insert connectors - faston x 0,5 mm. Ordering codes Cover protection category Type Contact material Number and type of contacts Connection mode Additional features Contact material 10 - AgCdO 20 - AgNi see Tables 1, 2 page 7 Number and type of contacts - 2 C/O Cover protection category 2 - in cover, IP 40 version 4 - in cover with mounting flange, IP 40 version Connection mode 6 - for flat insert connectors - faston x 0,5 mm and plug-in sockets Additional features ❶ without marks - without additional features L - light indicator (LED diode) D - surge suppresion element (diode) LD - light indicator (LED diode) + surge suppresion element (diode) ❶ D, LD - only for DC coils Examples of ordering codes: RY2-20-26-10 RY2-20-26-5230-L relay RY2, contact material AgNi, with two changeover contacts, in cover IP 40, for flat insert connectors - faston x 0,5 mm and plug-in sockets, voltage version V DC relay RY2, contact material AgNi, with two changeover contacts, in cover IP 40, for flat insert connectors - faston x 0,5 mm and plug-in sockets, voltage version 230 V AC 50/60 Hz, with light indicator (LED diode)

Plug-in sockets and accessories for relays RY2 GZY2 Connection diagram Dimensions For RY2 NO 14 Screw terminals Maximum screw torgue: 0,7 Nm 35 mm rail mount acc. to PN-EN 60715 or on panel mounting 67 x x 25 mm Two poles A, 250 V AC NC 8 M3,5 4,2 18 COIL COM -A2 21 13 +A1 9 11 67 47 2,5 26 30 14,5 25 Accessories GZY 2000 GZ2 1111