MetaXpress Image Acquisition and Analysis Software Version 3.1



Similar documents
MetaXpress High Content Image Acquisition & Analysis Software

MetaMorph Microscopy Automation & Image Analysis Software Super-Resolution Module

MetaXpress PowerCore High Content Distributed Image Analysis Software

Molecular Devices High Content Data Management Solution Database Schema

MDCStore High Content Data Management Solution Database Schema

Dell Statistica Statistica Enterprise Installation Instructions

StatusScope Remote Monitoring Service. Mobile User Guide

Eksigent Method Merger Tool for Analyst Software. User Guide

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

WhatsUp Gold v16.2 Installation and Configuration Guide

Installation Instruction STATISTICA Enterprise Small Business

MetaXpress Image Acquisition and Analysis Software. Analysis Guide Version 2.0 for Microsoft Windows XP

INSTALLATION GUIDE. AXIS Camera Station

Printer Driver Installation Guide

Installation Guide. Wyse R Class Conversion to Xenith Pro. Wyse USB Firmware Tool TM Release 1.18 Products: R10L, R50L, R90L, R90LW, R90L7

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Mobility Services Platform Software Installation Guide

COM Port Stress Test

Lepide Event Log Manager: Installation Guide. Installation Guide. Lepide Event Log Manager. Lepide Software Private Limited

WhatsUp Gold v16.1 Installation and Configuration Guide

2.6.1 Creating an Acronis account Subscription to Acronis Cloud Creating bootable rescue media... 12

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version

The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. GITCON

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

USB DRIVER INSTALLATION GUIDE

SOFTWARE INSTALLATION INSTRUCTIONS

Dell Statistica Document Management System (SDMS) Installation Instructions

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

Installation Instruction STATISTICA Enterprise Server

SMS Database System Quick Start. [Version 1.0.3]

Stellar Phoenix Windows Data Recovery. Stellar Phoenix Windows Data Recovery 5.0 User Guide

Registered Trademarks and Proprietary Names

Server Installation Guide ZENworks Patch Management 6.4 SP2

SiI3132 SATARAID5 Quick Installation Guide (Windows version)

Enterprise Server. Application Sentinel for SQL Server Installation and Configuration Guide. Application Sentinel 2.0 and Higher

Installation Guide Sybase ETL Small Business Edition 4.2 for Windows

Diamond II v2.3 Service Pack 4 Installation Manual

Magaya Software Installation Guide

Operating System Installation Guide

Installing the Microsoft Network Driver Interface

Printer Driver Installation Manual

KofaxExpress. Installation Guide

SharpdeskTM R3.1. Installation Guide Version

Global Server Installation Guide

CS SoftDent Practice Management Software Installation Guide for Client/Server Configurations

NTP Software File Auditor for Windows Edition

Installing the Gerber P2C Plotter USB Driver

ZConverter. Windows Backup v 3.5

RDC-7 Windows XP Installation Guide

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation.

Windows Data Recovery Home 6.0

hp digital home networking wireless USB network adapter hn210w quick start guide

Portions of this product were created using LEADTOOLS LEAD Technologies, Inc. ALL RIGHTS RESERVED.

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

Users Guide. Wyse USB Firmware Tool Issue: PN: Rev. K

WhatsUp Gold v16.3 Installation and Configuration Guide

e-dpp May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database

Virtual Owl. Guide for Windows. University Information Technology Services. Training, Outreach, Learning Technologies & Video Production

ScanShell.Net Install Guide

Installation & Activation Guide

Pacesetter BES Lettering Installation Guide

Sage Intelligence Financial Reporting for Sage ERP X3 Version 6.5 Installation Guide

Installation Guide for Workstations

Acronis Backup & Recovery 11

Quick Start Guide

Stellar Phoenix. SQL Database Repair 6.0. User Guide

Analyst 1.6 Software. Laboratory Director s Guide

Any system currently running the Schneider Electric MBX Driver Suite or any activated Cyberlogic software suite.

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

FedEx Ship Manager Software. Installation Guide

STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS

CS SoftDent Practice Management Software Installation Guide for Client/Server Configurations

SolarWinds Migrating SolarWinds NPM Technical Reference

Stellar Phoenix. Access Database Repair 5.0 Installation Guide

Installation & Upgrade Guide. Hand-Held Configuration Devices Mobility DHH820-DMS. Mobility DHH820-DMS Device Management System Software

How to use the VMware Workstation / Player to create an ISaGRAF (Ver. 3.55) development environment?

Pipeline Compliance System v7.6. Installation Guide

Batch Eligibility Long Term Care claims

AMS Suite: Machinery Health Manager

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

Backup & Disaster Recovery Appliance User Guide

Upgrading from Call Center Reporting to Reporting for Contact Center. BCM Contact Center

ivms-4200 Client Software Quick Start Guide

Microsoft Dynamics GP. Electronic Signatures

Sage 100 ERP. Installation and System Administrator s Guide

VERITAS Backup Exec TM 10.0 for Windows Servers

Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers

Installation Assistance Windows/Microsoft Updates Updating from Spectra or Upgrading from Spectra 6.x...

Driver Installation for Windows XP Home Edition and Windows XP Professional

User Guide. CTERA Agent. August 2011 Version 3.0

UPS WorldShip Install on a Workgroup Remote

Replacing a MealTime Point of Sale Computer

Bosch ReadykeyPRO Unlimited Installation Guide, product version 6.5. This guide is item number DOC , revision 2.029, May 2012.

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

LabelWriter. Print Server. User Guide

Reconfiguring VMware vsphere Update Manager

MGC WebCommander Web Server Manager

Guide to Installing BBL Crystal MIND on Windows 7

Installing Novell Client Software (Windows 95/98)

Transcription:

MetaXpress Image Acquisition and Analysis Software Version 3.1 For ImageXpress Micro and ImageXpress Ultra Instrument Workstations Upgrade Guide 5001659 Rev. B June 2010

This document is provided to customers who have purchased Molecular Devices, Inc. ( Molecular Devices ) equipment, software, reagents, and consumables to use in the operation of such Molecular Devices equipment, software, reagents, and consumables. This document is copyright protected and any reproduction of this document, in whole or any part, is strictly prohibited, except as Molecular Devices may authorize in writing. Equipment, software, reagents, and consumables that may be described in this document are protected under one or more patents filed in the United States, Canada, and other countries. Additional patents are pending. Software that may be described in this document is furnished under a license agreement. It is against the law to copy, modify, or distribute the software on any medium, except as specifically allowed in the license agreement. Furthermore, the license agreement may prohibit the software from being disassembled, reverse engineered, or decompiled for any purpose. Portions of this document may make reference to other manufacturers and/or their products, which may contain parts whose names are registered as trademarks and/or function as trademarks of their respective owners. Any such usage is intended only to designate those manufacturers' products as supplied by Molecular Devices for incorporation into its equipment and does not imply any right and/or license to use or permit others to use such manufacturers' and/or their product names as trademarks. Molecular Devices makes no warranties or representations as to the fitness of this equipment for any particular purpose and assumes no responsibility or contingent liability, including indirect or consequential damages, for any use to which the purchaser may put the equipment described herein, or for any adverse circumstances arising therefrom. For research use only. Not for use in diagnostic procedures. The MDCStore SDK and associated documentation are copyrighted and property of Molecular Devices, Inc. Use of the MDCStore API (Application Programming Interface) and acceptance of the associated documentation is prohibited without the express written consent of Molecular Devices, Inc., which consent shall limit the scope of use of the MDCStore technology, shall be personal to the licensed user, and shall be non-transferable. ACUITYXPRESS, ADAPTIVE ACQUISITION, MDCSTORE, and MDCSTORETOOLS are trademarks and METAXPRESS, METAMORPH, META IMAGING SERIES, TRANSFLUOR, and IMAGEXPRESS are registered trademarks of Molecular Devices, Inc. These trademarks may not be used in any type of promotion or advertising without the prior written permission of Molecular Devices, Inc. Equipment built by Molecular Devices, Inc. 1311 Orleans Drive, Sunnyvale, California, United States of America 94089. Molecular Devices, Inc. is ISO 9001 registered. 2010 Molecular Devices, Inc. All rights reserved. Printed in the USA.

Contentsents Before You Begin............................... 3 Suggested Workflow............................ 4 Install the MetaXpress Software.................. 5 Install the Latest Update of the MetaXpress Software 14 Install Version 9 of the USB Driver................ 21 Configure the Objectives........................ 24 Check for Updates............................. 30 5001659 B 1

2 5001659 B

Upgrading the MetaXpress Software Before You Begin This guide provides instructions on how to upgrade the MetaXpress software from version 2 or version 3.0 to version 3.1 on ImageXpress Micro and ImageXpress Ultra instrument workstations. To see a list of the features of version 3.1 of the MetaXpress software, read the release notes on www.meta.moleculardevices.com/mxupdates. To view a presentation on the new MDCStoreTools TM application and the new Laser Autofocus wizard included with version 3.1 of the MetaXpress software, go to https://moldevents.webex.com. On the web site, click High-Content Cellular Imaging and then select the webinar New Laser Autofocus Wizard and Data Management Tools with MetaXpress 3.1. Before upgrading to version 3.1 of the MetaXpress software, perform the following tasks: Read the MetaXpress Image Acquisition and Analysis Software Installation Guide for Version 3.1, available on the MetaXpress 3.1 software installation CD. Make sure you are logged in as Administrator on the instrument workstation. Make sure the C: drive has at least 1 GB of available space. For ImageXpress Ultra systems, delete all files starting with FS_ in the C:\Documents and Settings\window login account\local Settings\Temp folder. Earlier versions of the MetaXpress software did not delete these files, which are created when images are larger than 10 MB. Version 3.1 of the software deletes these temporary files appropriately. 5001659 B 3

Upgrading the MetaXpress Software Suggested Workflow Upgrading to version 3.1 of the MetaXpress software involves several steps, most of which can be performed using the MetaXpress 3.1 software installation CD. The following table lists the tasks required in the order they should be performed. Task Install version 3.1 of the MetaXpress software on the instrument workstation. Download and install the latest update for version 3.1 of the MetaXpress software. Install version 9 of the USB driver. Configure the numerical apertures and working distances of the objectives. Update the MDCStore TM database to version 2.2. Instructions See Install the MetaXpress Software on page 5 See Install the Latest Update of the MetaXpress Software on page 14 See Install Version 9 of the USB Driver on page 21 See Configure the Numerical Apertures and Working Distances of Objectives on page 24 See the MDCStore TM 2.2 Database Schema Installation and Update Guide* Install the MDCStoreTools TM application. See the MDCStoreTools TM 1.1 User Guide* Create a user account with Administrator privileges on the MDCStore database schema. See the MDCStoreTools TM 1.1 User Guide* *These manuals are included on the MetaXpress 3.1 software installation CD. Note: Version 3.1 of the MetaXpress software will work with version 2.0 of the MDCStore TM database. However, to use the MDCStoreTools TM applications, you must upgrade the MDCStore database to version 2.2. 4 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide Install the MetaXpress Software CAUTION! Molecular Devices, Inc. assumes no responsibility for any damage to existing user data that may occur due to network problems, power failure, unexpected termination during the update process, user customization of an existing MDCStore TM database, and so on. You must fully back up your existing database before beginning an installation or upgrade procedure. Note: The 64-bit version of the MetaXpress 3.1 software is for offline use only. To install the MetaXpress software 1. Insert the MetaXpress 3.1 software installation CD into the computer s CD-ROM drive. If the installation screen does not appear, go to the CD folder and double-click autorun.exe. Note: If you do not have the MetaXpress 3.1 software installation CD, contact Molecular Devices, Inc. Support at www.moleculardevices.com/support. You will need to provide your System ID. The MetaXpress software installation screen appears. 5001659 B 5

Upgrading the MetaXpress Software 2. Click Install MetaXpress 3.1: 32-bit. A message appears asking you to confirm the installation. 6 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide 3. Click Yes. The MetaXpress 3.1 software installation wizard appears. 4. Click Next. The software license agreement appears. 5. Select I Accept all terms of the preceding License and then click Next. The Sentinel Security Components page of the installation wizard appears. 6. Click Next. 7. If the installation wizard does not detect an earlier version of the MetaXpress software on the instrument workstation, skip to Step 10. If an earlier version of the software is detected on the instrument workstation, the message below appears. 5001659 B 7

Upgrading the MetaXpress Software 8. Select Copy the settings from this folder into a new destination folder and then click OK. Note: The installation wizard uses the settings from the copy of the MetaXpress software that was most recently open. If you want to install the MetaXpress software using the settings from a different copy of the software, close the installation wizard, open the other copy of the MetaXpress software and then close it, and then start the installation again from the beginning. 8 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide The Browse for Folder dialog box appears. 9. Create a folder for the new copy of the MetaXpress software, and click OK. The Destination Folder page of the installation wizard appears. 5001659 B 9

Upgrading the MetaXpress Software 10. Make sure the C: drive has enough space available as indicated in the Disk Space Limits section of the dialog box, change the destination folder if needed, and then select Next. The Program Group Selection page of the installation wizard appears. 11. Change the name of the program group if needed, and click Next. 10 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide The Hardware Key Confirmation page of the installation wizard appears. 12. Make sure the USB key for the MetaXpress software is inserted into the instrument workstation, select Use Local Key and then click Read System ID from Key. The installation wizard displays your System ID in the System ID field. 13. Click Next. 5001659 B 11

Upgrading the MetaXpress Software The User Information and Codes page of the installation wizard appears. 14. Enter the codes using one of the following methods: If the instrument workstation is connected to the internet, click Using the Internet. The installation wizard retrieves the codes and displays them in the appropriate fields. If the codes are on a disk, insert the disk and click From a Disk. The installation wizard copies the codes from the disk to the appropriate fields. If the instrument workstation is not connected to the internet, click Manually and type the registration and authorization codes in the appropriate fields. You can find the codes on the letter that accompanied your order. Or, you can go to www.meta.moleculardevices.com/authorize/ to find the codes (you must provide your System ID on the web page). 15. Click Next. 16. Click Install. 12 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide The installation wizard installs version 3.1 of the MetaXpress software and then opens the Meta Imaging Series Administrator software. 17. To create a folder on the desktop, click Create Icons. 18. Click OK. The Installation Complete page of the installation wizard appears. 19. Click Finish. 5001659 B 13

Upgrading the MetaXpress Software Install the Latest Update of the MetaXpress Software Updates for the MetaXpress software are available for download on the Molecular Devices web site, as described below. If you are unable to download the update, please send an email to Support using the web site www.moleculardevices.com/support or call 1-800-635-5577 and request that the latest update be sent to you. You will be asked for your System ID and the version of the software that you are requesting. To install an update of the MetaXpress software 1. Go to www.meta.moleculardevices.com/mxupdates. 2. Enter your System ID and click Log In. Your System ID is on your USB key and in the letter that accompanied your order. The web page that appears lists the available updates for the MetaXpress software. 3. Select the latest update. The Update page for the update that you selected appears. For example: 4. Click on the link for the 32-bit version to download the update file. 5. When the license agreement appears, click I ACCEPT THE TERMS IN THIS AGREEMENT. 14 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide A yellow bar appears indicating that the site is blocked from downloading. 6. Click the yellow bar and, in the menu that appears, select Download File. The File Download dialog box appears. 7. Click Save, choose a location on your hard drive for the update file in the Save As dialog box and then click Save again. Note: You can save the update file to a USB flash drive or DVD, which is especially useful if you are updating the MetaXpress software on more than one instrument workstation. CAUTION! Do not attempt to unzip the update file. The Meta Imaging Series Updater unzips the file during the update process. 5001659 B 15

Upgrading the MetaXpress Software 8. From the Windows Start menu, select Programs>Meta Imaging Series>Meta Imaging Series Updater. The Meta Imaging Series Updater opens. 9. Click Next. The Select Patch File page of the Meta Imaging Series Updater appears. 10. Select the ellipsis (...) button. 16 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide The Open dialog box appears. For example: 11. Navigate to the update file, select it, and then click Open. The Select Patch File page appears, displaying the path name of the update file that you selected. 12. Click Next. 5001659 B 17

Upgrading the MetaXpress Software The Hardware Key Confirmation page of the Meta Imaging Series Updater appears. 13. Make sure the USB key for the MetaXpress software is inserted into the instrument workstation, select Use Local Key and then click Read System ID from Key. The Meta Imaging Series Updater displays your System ID in the System ID field. 14. Click Next. 18 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide The User Information and Codes page of the Meta Imaging Series Updater appears. 15. Enter the codes using one of the following methods: If the instrument workstation is connected to the internet, click Using the Internet. The Updater retrieves the codes and displays them in the appropriate fields. If the codes are on a disk, insert the disk and click From a Disk. The Updater copies the codes from the disk to the appropriate fields. If the instrument workstation is not connected to the internet, click Manually and type the registration and authorization codes in the appropriate fields. You can find the codes on the letter that accompanied the order. Or, you can go to www.meta.moleculardevices.com/authorize/ to find the codes (you will be asked to enter your System ID). 16. Click Next. The Ready to Proceed page of the Meta Imaging Series Updater appears. 17. Click Update. 5001659 B 19

Upgrading the MetaXpress Software When the installation is complete, the following page appears: 18. Click Finish. The Meta Imaging Series Updater opens the Meta Imaging Series Administrator software. 19. Click OK. 20 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide Install Version 9 of the USB Driver You must update the USB driver on all instrument workstations. If you do not update the driver, the ImageXpress Micro and ImageXpress Ultra systems will not operate properly. Note: You do not need to install the driver on computers that are not used for acquisition. To update the driver 1. Make sure you are logged in as Administrator on the instrument workstation. 2. Insert the MetaXpress 3.1 software installation CD into the computer s CD-ROM drive. If the installation screen does not appear, go to the CD folder and double-click autorun.exe. 5001659 B 21

Upgrading the MetaXpress Software The MetaXpress installation screen appears. 3. Click Install IXM/IXU USB Driver V9: 32 bit. A message appears asking you to confirm the installation. 4. Click Yes. 22 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide The WinZip Self-Extrator dialog box appears. 5. Click Setup. The following page appears. 6. If the installation wizard detected an earlier version of the driver on the computer, select Repair WinDriverMDC. 7. Click Finish. 8. When the Installation Complete page appears, click Close. 5001659 B 23

Upgrading the MetaXpress Software Configure the Numerical Apertures and Working Distances of Objectives To configure the objectives 1. From the Windows Start menu, select Programs>Meta Imaging Series>Meta Imaging Series Administrator. The Meta Imaging Series Administrator appears. 2. In the List of Groups, select the Group Name for version 3.1 of the MetaXpress software, and then click Configure Hardware. The Configure Hardware dialog box appears. 24 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide 3. In the Hardware Settings section, select the appropriate hardware configuration (for example, IXM or IXU ), and then click Configure Acquisition. Note: If multiple hardware configurations exist (for example, multiple objective configurations or filter cube configurations), perform Steps 3-11 for each configuration. The Configure Acquisition dialog box appears. 4. For ImageXpress Ultra systems, ensure that ImageXpress Ultra is listed in the Installed Drivers section of the dialog box. 5. For ImageXpress Micro systems, ensure that Photometrics is listed in the Installed Drivers section of the dialog box. 5001659 B 25

Upgrading the MetaXpress Software 6. Click OK. The Configure Hardware dialog box appears. 7. In the Hardware Settings section, select the appropriate hardware configuration (for example, IXU or IXM ), and then click Configure Devices. 26 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide The User Settings for the hardware configuration dialog box appears. For example: 8. In the Claimed Devices section, select the objective (for example, ImageXpress Micro Objective or ImageXpress Ultra Objective ), and then click Settings. 5001659 B 27

Upgrading the MetaXpress Software The settings for the objective appear. For example: Using the following table, verify the numerical aperture and the working distance of each objective. Also, verify that the type of media is correct; if you are using oil or water, be sure to enter an appropriate refraction index. Note: If the working distance of an objective is a range of numbers (for example, the 20x ELWD objective), use the smallest number. 28 5001659 B

MetaXpress Image Acquisition and Analysis Software Upgrade Guide Objective Magnification and Type * Recommended basic configuration ** Common objectives Numerical Aperture 1x Plan Achromat 0.04 3.2 Working Distance (mm) 4x S Fluor* 0.20 15.5 4x Plan Apo** 0.20 15.7 4x Plan Fluor DL 0.13 16.2 10x Plan Fluor* 0.30 16 10x S Fluor** 0.50 1.2 10x Plan Fluor DLL 0.30 16 10x Plan Fluor DL 0.30 15.2 20x Plan Fluor ELWD cc 0-2mm* 0.45 8.1-7.0 20x S Fluor** 0.75 1 20x Plan Apo 0.75 1 20x Plan Fluor DLL 0.50 2.1 20x Plan Fluor ELWD DM cc 0-2mm 0.45 8.1-7.0 40x Plan Fluor ELWD cc 0-2mm* 0.60 3.7-2.7 40x Plan Apo cc 0.11-0.23 mm** 0.95 0.14 40x S Fluor cc 0.11-0.23 mm** 0.90 0.3 40x Plan Fluor Oil 1.30 0.2 40x Plan Fluor DLL 0.75 0.72 40x Plan Fluor ELWD DM cc 0-2 mm 0.60 3.7-2.7 60x Plan Fluor ELWD cc 0.5-1.5 mm* 0.70 2.1-1.5 60x Plan Fluor ** 0.85 0.3 60x Plan Apo Oil 1.4 0.21 60x Plan Fluor ELWD DLL cc 0.5-1.5 mm 0.70 2.1-1.5 100x Plan Fluor cc 0.14-0.20 mm** 0.95 0.2 100x Plan Fluor Oil 1.30 0.2 5001659 B 29

Upgrading the MetaXpress Software 11. Click OK. Repeat Steps 3-11 for each configuration that exists. Check for Updates to the MetaXpress Software and MDCStore Database Molecular Devices, Inc. recommends that you always use the latest available version of the MetaXpress software and MDCStore TM database. Periodically check the Molecular Devices web site, www.moleculardevices.com, for updates. 30 5001659 B