IntesisBox KNX - LON



Similar documents
IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus TCP master

IntesisBox ASCII Server - LON

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

KNX Panasonic Air Conditioners

IntesisBox Modbus Server Fidelio IP

IntesisBox KNX LG Air Conditioning

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox KNX Mitsubishi Heavy Industries AC

Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox. Making Building Automation go further. KNX EIB Products

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007

Inwall Room Temperature Unit

TX OPEN RS232/485 module

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Rack mounted telephone- and leased line modem for industrial applications

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Inwall 4 Input / 4 Output Module

IntesisBox DK-RC-ENO-1iC. EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Telephone- and leased line modem for industrial applications TD-36

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

IntesisBox. Making Building Automation go further. Modbus Products

PCS0100en Persy Control Services B.V. Netherlands

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Digital input modules

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

KNX Interface. User Manual PM00A00IRI

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

QSE-CI-NWK-E Control Interface

Unidirectional Transmitter/ Receiver Units Introduction

User manual Compact Web PLC WP240 series IEC-line

Product and functional description

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

OZS Web server. For LPB/BSB plants

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

FX07 Field Controller

iridium for Weinzierl KNX IP BAOS

HARTING econ 3000 Introduction and features

IntesisBox DK-RC-KNX-1

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

How To Use A Power Supply On A Powerline 2.2 (Ai)

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

connecdim Gateway G1 Ethernet TCP/IP to DALI

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

EDI Distributor Control Interface Wiring and Setup Instructions

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

CQM1-SF200/CS1W-SF200

NX safety stand-alone

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial Networks & Databases

Model: DC-A2IO Advanced HVAC Controller

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

HMI display Installation Guide

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI (LonTalk ) and ANSI 852 (IP) standards based.

Remote Monitoring and REC 501 Control Unit Product Guide

Application/Connection Examples

Duct Humidity Transmitter

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

NetBiter webscada Modbus User Manual

Controller board and power supply for vivimat III systems

HARTING mcon 1000 Introduction and features

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ELCOMPONENT LTD. User Manual

R60 USB to CAN interface Manual (1.5 EN)

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Optimize your simple machines... Modicon M218 Selection Guide

OZW V2.0. Web server. Synco TM, Synco TM living

NC-12 Modbus Application

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

HARTING mcon 3000 Introduction and features

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Niko Home Control. Installation Manual

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Technical Manual MDT Rain sensor

FX07 Field Controller

VOICE RECORDING SYSTEM ISDN PRI / BRI

INSTALLATION GUIDE 1

Waveguide Access Point WGA631. Product Guide

iridium for KNX/EIB Fast Start: Connection Setting Manual for KNX/EIB equipment

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Passion for KNX innovation

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

DeltaV SISnet Repeater

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Bluetooth HC-06 with serial port module Easy guide

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

Transcription:

IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu, General ) into your KNX control system. KNX EIB Bus IntesisBox TP-FT/10 device device LinkBoxEIB Configuration Software RS232 Only needed for configuration IntesisBox is a KNX device allowing to read/write network variables (SNVTs) of devices connected to a network, and offering these values through its KNX/EIB interface. SNVT values in can be read/write from KNX. Each basic data type of a network variable in devices can be mapped into an individual KNX group address. interface of IntesisBox reads continuously by polling the devices configured, no bindings are required between IntesisBox and the devices. All the updated readings are maintained in IntesisBox memory for immediate interaction with the KNX system when needed. The IntesisBox KNX EIB interface connects directly to the KNX bus and is opto-isolated from the rest of internal electronics. devices can be addressed either using Neuron-Id (physical address) or subnet/node (commissioned devices). IntesisBox has the ability to declare devices as commissioned, if needed, thus avoiding the need for a integration tool for commissioning (i.e. LonMaker). IntesisBox KNX series are configured using LinkBoxEIB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. With the standard installation of LinkBoxEIB, some Demo projects for integration of devices of the main manufacturers of Air Conditioners are provided (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy, Toshiba ). Using these demo projects makes the engineering needed for this kind of integration extremely easy and quick. 1 / 10

IntesisBox capacity Element 100 version Type of devices A version B version Notes Those supporting Twisted Pair Free Topology channel (TP/FT-10) Number of datapoints 100 500 4000 Maximum number of points (KNX group addresses) that can be defined into IntesisBox. Each of them can contain an individual field of a network variable. Number of devices supported 128 128 128 Maximum number of different devices that can be defined into IntesisBox (to read/write points into them). There are three versions of IntesisBox KNX- with different capacity: Version with capacity of 100 points and up to 128 devices. Ref. IBOX-KNX--100. Version with capacity of 500 points and up to 128 devices. Ref. IBOX-KNX--A. Version with capacity of 4000 points and up to 128 devices. Ref. IBOX-KNX--B 2 / 10

Sample applications Integration of any device or system into KNX control systems. KNX EIB Bus IntesisBox TP-FT/10 device device KNX control system: Building Automation. Home Automation. Typical devices or Systems equipped with interface: Air conditioners (Daikin, Mitsubishi Electric, Mitsubishi Heavy, Toshiba, Fujitsu, General ). Chillers. Heaters. Thermostats. Fan coil controllers. Room controllers. Power meters. Energy meters. Building Control Systems (BMS). Programmable Logic Controllers (PLC).... KNX System monitoring / controlling Full monitoring and control System under monitoring / control 3 / 10

Typical applications Integration of Daikin VRV Air Conditioning into KNX control systems. For this application, Daikin VRV Air Conditioning system must be equipped with Daikin gateway (model DMS504B51), this Daikin gateway is normally commissioned by Daikin technical personnel, contact your nearest Daikin distributor for details. Indoor units DIII-NET Outdoor units DMS504B51 Free Topology (FT-10) network EIB IntesisBox KNX - In the technical documentation of IntesisBox, supplied with the device, extended details on how to configure IntesisBox for this application are provided. Also, with the standard installation of LinkBoxEIB, which is the configuration software tool for IntesisBox, a Demo project for this application is provided, this demo project contain specific configuration to integrate Daikin VRV equipped with DMS504B51 interface, using this sample project the configuration and commissioning of IntesisBox for this application becomes easy and quick. 4 / 10

Integration of room controllers into KNX control systems. Room controllers Free Topology (FT-10) network EIB IntesisBox KNX - network variable interface for each particular room controller should be mapped into IntesisBox configuration. LinkBoxEIB software eases this task by providing a list of standard network variable types (SNVTs), with their respective fields, which can be assigned to each point. User-defined network variable types (UNVTs) can also be integrated, by entering their particular definition (a, b and c scale factors, basic data types of its fields ) into LinkBoxEIB configuration files. Each field of each network variable can be translated into a KNX data point, of any KNX-compatible type, at the KNX side of IntesisBox. Field values for input and output network variables can be sampled periodically (from to KNX). Values for input network variables can also be written (from KNX to ). Configuration template files for every specific manufacturer/model of device to be integrated can be constructed and supplied on demand. With this, the configuration of the gateway becomes easy and quick. Consult us for details. 5 / 10

KNX interface of IntesisBox KNX/EIB interface Bus coupler Internal KNX TP1 (EIB) opto-isolated bus coupler unit for direct connection to EIB bus. Connector: 2 poles plug-in screw terminal block. Configuration parameters Interactivity with KNX/EIB system KNX EIS (Datapoints) supported Physical address. When IntesisBox starts up, or after an EIB bus reset detection, all the updated values read from system will be sent to KNX. Configurable individually per point. Any change detected in system (i.e. Ambient Temperature of a VRV group) is immediay transmitted to KNX. Configurable individually per point. Any point value can be updated with a read request sent to KNX when IntesisBox starts up or after a KNX bus reset detection (i.e. Temperature Set Point). Configurable individually per point. Switching (1 bit). Dimming (4 bits). Float (16 bits). Scaling (8 bits). Drive Control (1 bit). Priority (2 bits). Float IEEE (32 bits). Counter (16 bits). Counter (32 bits). Counter (8 bits). ASCII char (8 bits). 6 / 10

interface of IntesisBox Specifications supported channel: Free Topology (FT-10) Configurable addressing options (on a per device basis): Subnet / node Neuron-Id Network variable sample rate: Below 60ms per network variable (each network variable may contain several fields, which will be mapped to different KNX data points, if needed). Supported network variable types: All standard network variable types published by LonMark International are directly supported by the configuration tool LinkBoxEIB. Support for user-defined network variable types can be added in each case, by entering their definition in LinkBoxEIB. In this case, the following information needs to be provided: Scale factors: a, b and c Number of fields Basic data type of each field Supported basic data types Basic data type Description Signed short 8-bit signed data Unsigned short 8-bit unsigned data Enum 8-bit unsigned data Signed long 16-bit signed data Unsigned long 16-bit unsigned data Signed quad 32-bit signed data Unsigned quad 32-bit unsigned data Float 32-bit IEEE float Bitfield 1 to 8-bit length unsigned bitfield 7 / 10

Configuration tool LinkBoxEIB Visual engineering tool, easy of use, for IntesisBox s configuration and monitoring compatible with Microsoft Windows operating systems, supplied with the purchase of IntesisBox with no additional cost. Multi-window tool allowing to monitor simultaneously the communication activity with both protocols (systems), real time values for all the points allowing to modify any value (very useful for test purposes), console window showing debug and operation status messages, and configuration windows to configure all the IntesisBox s parameters and internal points. Point configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the IntesisBox s parameters and points while in off-line (not connected to the gateway). Connection to the IntesisBox for download the configuration and monitoring by using serial COM port of the PC (serial cable also supplied). Allows configuring all the external protocols available for IntesisBox KNX series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox KNX series. Multi-project tool allowing having in the engineer s PC the configuration for all the sites with different IntesisBox KNX series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the IntesisBox for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ). 8 / 10

Technical characteristics Plastic, type PC (UL 94 V-0). Enclosure Dimensions: 107mm x 105mm x 58mm. Colour Light Grey. RAL 7035. 9 to 30Vdc +/-10%, Max.: 125mA. 24Vac +/-10% 50-60Hz, Max.: 127mA Power Must use a NEC Class 2 or Limited Power Source (LPS) and SELV rated power supply. Plug-in terminal block for power connection (2 poles). Terminal wiring (for power supply and low-voltage signals) Mounting port Per terminal: solid wires or stranded wires (twisted or with ferrule) 1 core: 0.5mm 2 2.5mm 2 2 cores: 0.5mm 2 1.5mm 2 3 cores: not permitted Wall. DIN rail EN60715 TH35. 1 x (TP-FT/10). Plug-in terminal block (2 poles). TNV-1 1 x KNX TP1 (EIB) port opto-isolated. Plug-in terminal block (2 KNX port poles). TNV-1 1 x Power. 2 x KNX port activity (Tx, Rx). LED indicators 2 x port activity (Tx, Rx). 1 x KNX programming/bus. 1 1 x service led. 1 1 x KNX programming. 1 Push buttons 1 x service switch. 1 Console port EIA232. DB9 female connector (DCE). SELV Configuration Via console port. 2 Firmware Allows upgrades via console port. Operational -25 C to +70 C temperature Operational 25-90% at 50ºC, non condensing humidity Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). CE conformity to EMC directive (2004/108/EC) and Low-voltage directive (2006/95/EC) Norms and EN 61000-6-2 standards EN 61000-6-3 EN 60950-1 EN 50491-3 1 2 Not operational for the moment. Reserved for future use. Standard cable DB9male-DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied. 9 / 10

Dimensions Power KNX port 58 mm port Console port 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections: 100 mm 115 mm 130 mm 10 / 10