SATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND



Similar documents
HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

XP Series Balances Operation Manual

Operating instructions Platform/floor scales

High precision counting scale. Operation Manual. l RCZ-A Series

How To Use A Ci 2001A/B (I2) With A Power Supply (I3)

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

BW-500 BED WEIGHER USER MANUAL

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Model UT713 OPERATING MANUAL

Instruction Manual FL

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

Adam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008)

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Operating Manual Electronic Wheelchair Scale with cable display M50610

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Keep it Simple Timing

RAINCONTROL LCD Special

Ingenico. User Guide 5100M. Secure transaction and payment solutions

OCSM Series. High Resolution Digital Crane Scale. User Guide

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Virtual Measurements & Control. Flip/Flop Filler

BLOOD COLLECTION MIXER

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

OCS-S High Resolution Digital Crane Scale

INDUSTRIAL INSTRUMENTATION

LDG DTS-4/4R Desktop Coaxial Switch / Remote

HIGH PRECISION WEIGHING SCALE. Operation Manual. l RCZ-B Series

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

Series 6000 Torque measured metal bellow coupling

LTM-1338B. Plus Communications Manual

MICROSYNC. User Manual. Microgate s.r.l. Via Stradivari, 4 Stradivaristr BOLZANO - BOZEN ITALY

1 Serial RS232 to Ethernet Adapter Installation Guide

User s Manual AURORA 1.2K/2.2K

Telephone- and leased line modem for industrial applications TD-36

Instruction Manual Service Program ULTRA-PROG-IR

GEU Port Gigabit Switch

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

PPM Users Manual Signature Software

Wind Sensor W-RS485 with RS485 Interface

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

STERILIZERS, LABORATORY DRYING OVENS

8-Port PoE Network Switch

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

Customer Pole Display SERIES 8035

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

How To Use A Power Supply Unit (Upu)

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

ANALYTICAL BALANCE OPERATION MANUAL. (FA/JA Series)

ISHIDA BC Scale to Scale Communications

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Incubator with mechanical convection

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Series 7500 Torque Sensor

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

Sartorius YAD01IS Win

10000HXL31/15000HXL31/20000HXL31

How To Use A Ds340 (Dsp)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

MANUAL PC1000R

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

Phoenix Body Fat Scale Manual

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

PERF10 Rubidium Atomic Clock

MagIC Installation Manual. Point of Sales Terminals TD06014B

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Changers Kalhuohfummi User Manual

IntesisBox KNX LG Air Conditioning

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

HT580 User Reference Guide. Version 1.0

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Optical Power Meter. Specification & User Manual

MAC Ope ra tor Terminal

Instruction Manual Crane Scales PCE-HS Series

T1 Weight Transmitter Profibus

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Chlorophyll Content Meter. CCM-200 plus

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Modbus Server SAMSUNG Air Conditioners

Register your product and get support at. AS111. User manual

Portable Air Conditioner

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Transcription:

- Manual SATEX SA 230 PRECISION BALANCE Weegtechniek holland b.v. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND Tel. + 31 36 522 20 30 Fax. + 31 36 522 20 60 Email info@satex.nl Website www.satex.nl

page 1 PCG/C SA 230 manual V2 21-06-07 General Thank you for purchasing this SATEX precision balance! This scale is equipped with reliable technology and has user friendly operational software. You will use it many times and it will prove itself to be an easy, speedy and accurate tool. If any questions raise that are not described in this manual, please address yourselves to your SATEX supplier, have a look at our website : www.satex.nl or send your questions per email to : info@satex.nl Application The SA 230 precision balance is designed for accurate weighing, for counting of articles and weighing in %. The scale is meant for use in dry, inside conditions. Humidity should be avoided. Pay attention to the maximum temperature limits in use. Prevent for moisture and dirt and avoid heat and sun radiation. The scale is designed for internal weighing and is not allowed for use for trade purposes (sales of products). Take care of a stable position of the scale. Place it in accurate level position with the help of the 4 levelling feet and the level indicator in the front panel. Important : all 4 of the feet should carry the scale equally. Safety Please read this manual thoroughly before start using the scale. The supplier does not accept any responsibility if the guidelines of this manual are not observed. Before any work is done on the scale, power connections from the mains adaptor and the internal battery should be interrupted. Warranty is void if the scale is opened anyhow. The instrument fulfils the requirements laid down in the EG regulations 89/336/EWG and 73/23/EWG for electromagnetic compatibility. Exceeding of the maximum values, laid down in these regulations, must be avoided. Reading values may be incorrect if strong electromagnetic fields are applied on to the scale. After removal of these influences the scale can be used normally again. Sometimes switching off and on again of the scale is required. Electrostatic discharges may cause fatal damage to the scale and should be avoided at all times. I.e. a proper earth connection of the scale and the place of erection is required in such cases. The mains adaptor has no special protection against humidity and water and should not come into contact with it. In case this has happened, or the adaptor shows any external damage, the adaptor should not be used any longer. The built in lead battery should, if it has to be replaced, be disposed off as small chemical waste, not to be added to normal waste. Maintenance Except from regular cleaning with a slightly humid cloth and a not aggressive detergent, further maintenance is not required. However it makes sense to check the scale s weighing accuracy with regular intervals, using accurate calibration weights. If necessary the scale may be adjusted with the quick calibration function if the deviation is not more than 0.5 % away from the actual weight value. If this proves to be more, the complete calibration procedure should be accomplished.

page 2 Start up sst weigh platform - Unpack the parts : weighing scale fixing bolt weighing platform ( 12 cm or 18 x14 cm) platform carrier platform carrier, incl. M3x16 bolt and hex. key mains adaptor in carton mounting cone - Remove with a turning movement the rubber protection lid that is placed over the mounting cone. - Place the platform carrier with a slight turning movement in the mounting cone and fix it with the M3 bolt. Do not turn on too heavily! RS data port Before removal of the platform, first turn it carefully. battery door - Set the scale level by means of the 4 levelling feet and the level power input indicator. Arrange for a stable position of the scale. (9V adapter) on/off switch - Plug in the mains adaptor and operate the on / off switch (leeg weegvlak!). level indicator - The scale sets automatically zero and is ready for use now. Caused by differences in temperature it may last until 10 minutes before the reading of the weight is completely accurate. Place the articles to be weighed carefully on the weigh platform. Prevent for bumping against and overloading of the weighing platform. The loadcell down under it may be damaged seriously. Check, if necessary, the accuracy with an accurate calibration weight. Using the quick calibration button the scale may be re-adjusted in a few seconds. At first start up the built in battery may be not completely loaded. Re-load the battery by leaving the scale for at least 8 hours with a connected mains adaptor. Technical specifications Weighing capacities - 300 g x 0,01 g division - 600 g x 0,01 g,, - 600 g x 0,02 g,, weigh platform 12 cm - 1200 g x 0,02 g,, - 1550 g x 0,05 g,, - 3100 g x 0,1 g,, weigh platform 18 x 14 cm Accuracy + of - 2 divisions Environmental temperature in operation: +5 +35 C, in stock: -10 + 55 C Housing ABS with steel base plate, IP 54 closed, dimensions 213 x 193 x 66 mm (lxwxh), weight 1,9 kg Power supply mains adaptor 230 VAC 50 Hz 60 ma, output 9 VDC 500 ma Operational time on battery 75 / 15 hours without / with display backup lightning switched on Battery charging time minimal 8 hours for a full charge Automatic switch off settable: auto switch off after 5, 10, 20, 30 minutes standstill or switched on continuously Display back light settable: on, off, or automatic switch on as soon as weigh platform is loaded with weight (reading > 0) RS data port (option) 2400 / 9600 Bd (settable), 8 data bits, 1 stop bit, no parity, CR and LF, fixed string 12 bytes, decimal dot and the g (gram) sign included, 9-pole male D-connector

page 3 Display: operating keys reading Front panel Set zero of the gross weight value, range + and - 2 % of weighing capacity. Start printer or data transmission to computer Quick calibration key after 3 seconds Tare = set zero within the Switching over from number of pieces (or % ) full weighing capacity to weight reading, and vice versa Switch to the counting program and % weigh function Switching between weight units (gram - ounce..) Underneath the display a number of symbols may be pointed at by an arrow in the display to show that this function is active. See example : reading is exact zero (backlight is switched on) The symbols represent the following functions: reading is exact zero (gross and net) reading is net (tare in operation) reading indicating in % reading indicating a number of pieces reading is not stable ( = Motion Detector) U reading is in another weight unit as: gram

page 4 Switching on The on/off switch is located at the left side of the housing. On switching on the display shows: Lod... (Loading) During the start up sequence the display counts backwards from 999999 to 000000. After that the type number appears: SA 230. As soon as exact standstill of the weight signal is present, the scale will set itself automatically at zero Only at exact standstill the arrow to the symbol will disappear and the weight reading goes to zero. The arrow at 0 now appears. After maximal 10 minutes warming up time the measuring system is stabilized and the scale is ready to be used. Zero setting If the unloaded weigh platform not presents a zero reading, operate the key. The zero setting range is max 2% of the weighing capacity. If more than 2 % zero setting is required, switch the scale off and on again. The zero range then is 10%. (see: error reports) Tare (taring is setting zero over the complete weighing range) Place f.e. empty carton on the platform and operate key:. After standstill the reading sets zero. The arrow at indicates a tare value is in operation: reading is net value. This may be repeated up to the maximum weighing capacity. Delete a tare with empty weigh platform, operating key: Plus / minus weighing (in weighing mode only) Place an article with the correct weight on the platform, operate key: The reading sets zero. The arrow appears. Now place the article to be checked and read the deviation in + of -. Delete a tare with empty weigh platform, operating key:

page 5 Counting pieces 1. First count by hand a number of articles: 10, 20, 50,100 or 200 pieces. The lighter the article, the more should be used for an accurate reference weighing. 2. Take care of a precise zero reading (0 arrow on ) and standstill ( arrow off ) of the reading, and place the pre-counted articles in one time on the weighing platform. Not too careful to prevent for auto zero effects. 3. Operate key:. The numbers that are available for the reference weighing now automatically are shown on the display one after the other. Operate key : again at the moment the right number is displayed. 4. The scale is now counting the number of articles, the display shows the number of pieces. The arrow at shows the counting mode is in operation. 5. may be switched from counting mode to weighing mode and back. In the weighing mode the article weight is kept memorized. % weighing For counting a new article, return to the weighing mode by key: and start with point 1 of this sequence. Note: in this program it is not possible to count correct negative numbers after taring 1. Take care of a precise zero reading (0 arrow on ) and standstill ( arrow off ) of the reading. 2. Place a weight (article) of exact 100% of the required weight on the weigh platform. 3. Operate key :. After the reference numbers for the counting procedure the value 100.0 appears and the arrow at switches on As long as this 100.0 is displayed, operate key : 4. The scale is now weighing in % of the 100% value that just has been entered. The display shows this percentage with an accuracy of 0,1%. The arrow at shows the percentage mode is in operation. 5. may be switched from % mode to weighing mode and back. In the weighing mode the % weight is kept memorized. For working with a new 100% reference, operate key weighing mode and start at point 1 of this sequence. for returning to the Note : in this program incorrect values occur if, after taring, a decreasing weight is applied.

page 6 Printing Transmit data (in the weighing mode only, string protocol see page 12) In the menu program 4 functions of the RS 232 comport may be selected : 0. switched off 1. printing (or transmission to PC) after operating key : Transmission starts as: - on pressing the key the reading has come to a standstill ( arrow is off ) - after the previous transmission the reading has been zero at least once - the reading is gross > 2 divisions - the scale is not in the counting or % mode. A short beep confirms the execution of the transmission. A long beep signals that the transmission has not been performed. 2. automatic 1 x printing (or transmission to PC) after each weighing Transmission starts as: - the reading has come to a standstill ( arrow is off ) - after the previous transmission the reading has been zero at least once - the reading is gross > 2 divisions - the scale is not in the counting or % mode. 3. continuous transmission Continuous transmission is executed with 5 Hz speed, as long as the scale is in the weighing mode and the gross reading is not negative.

page 7 Menu program The program mode is made accessible by pressing key switching on the scale with the on/off switch. As soon as the display shows : CAL release the key. Press key again to enter into the first menu function. After this, press key to step to the next menu functions. during The menu program may always be closed down by operating key 3 x, all the time with 1 second interval. Weight units There are 8 weight units available. As long as the unit : g (gram) has been selected, the key : is disabled during normal operation of the scale, to prevent for accidental use of this function. the available units may be shown one by one. gram grain the shown unit may be selected, after that the program will automatically step to the next menu function. ounce dwt If another unit than g (gram) has been selected, in normal operational mode troy ounce carat the key may be used to switch from g (gram) to the other unit and back. taiwan teal hong kong During this switching over shortly the symbol of the new unit is showed in the jewelery teal display. After switching the scale off and on again the preset unit is kept memorized. Automatic zero setting (Auto 0, keeps reading automatically on zero) off The automatic zero setting may be switched off, or may be set active within 1 of 2 divisions around the real zero. 1 division the available choices may be shown one by one. the shown choice may be selected, after that the program will 2 divisions automatically step to the next menu function. It is advised to deselect the auto zero if slow, small dosings starting from zero are regular procedures. This prevents for unwanted auto zero actions.

page 8 Automatic switch off (battery saving) This Auto off function switches off the scale automatically after.. minutes of standstill (not active in the program mode). 0 = auto off switched off 1 = 5 minutes 2 = 10 minutes 3 = 20 minutes 4 = 30 minutes the available times may be shown one by one. the shown choice may be selected, after that the program will automatically step to the next menu function. Back Light display (battery saving) The back lightning of the display may be selected as: 0 = always off 1 = always on 2 = automatically switching on at loading (reading > 0 ) the available choices may be shown one by one. the shown choice may be selected, after that the program will automatically step to the next menu function. Printing / transmission mode in weighing mode only ( RS 232 comport is optional) Transmission of data via the RS 232 port may be selected as: 0 = switched off 1 = 1 x transmission (printing) at, after standstill, operating key : 2 = 1 x automatic transmission after every weighing (passed zero and 3 = continuous transmission at 5 Hz standstill again) the available choices may be shown one by one. the shown choice may be selected, after that the program will automatically step to the next menu function. Baud rate ( RS 232 comport is optional) The Baud rate may be selected as: - 2400 Bd - 9600 Bd the available choices may be shown one by one. the shown choice may be selected, after that the program will automatically step to the next menu function.

page 9 Calibration weight The one key quick calibration function requires the selection of a fixed weight value, used for this quick calibration procedure. Depending of the weighing capacity of the scale there is the following selecting available, that will be shown in the display Capacity Choice of type of scale calibration weights 300 g 100, 200, 300 g 600 g 200, 400, 500, 600 g 1200 g 500, 1000, 1200 g 1550 g 500, 1000, 1500 g 3100 g 1000, 2000, 3000 g the available weight values may be shown one by one. The figures in this table indicated as fat will realise the best accuracy for that scale, in relation to the full weighing range. Make use of weights with sufficient accuracy, at least class M1. the shown weight may be selected, after that the program will automatically terminate the menu program : CAL.d appears. Operate key : to return to the weighing mode. Quick - Calibration start Keep key : pressed for longer as 3 seconds. The display will show during a few seconds the value of the required, accurate calibration weight, f.e.: 500 gram. download weight Now the display asks for putting this weight upon the platform: dl. 500 display flashes unload weight display flashes completed After putting the weight in place, the display will flash during some seconds, waiting for standstill and calculating the adjustment. As the display stops flashing, weight adjustment has been done. The display shows: u L, the calibration weight may be taken off the platform. After taking off the weight, the display again flashes for some seconds and the zero value will be adjusted. The calibration procedure is done now : CAL.d, the scale automatically switches back to the weighing mode. dl = down Load ul = un Load CAL.d = Calibration done

page 10 Complete Weight Calibration 1 The program mode is made accessible by pressing key during switching on the scale with the on/off switch. As soon as the display shows : CAL release the key. 2 Press one after the other the following key s: The display shows now: ra 1 of : ra 0. Select with the key: 1 = 0,5% tolerance check on quick calibration is in operation 0 = 0,5% tolerance check on quick calibration is disabled 3 Press key :. The internal measuring value of the empty platform is displayed. This value should be between 10.000 en 40.000. 4 Press key : as soon as the reading has come to a standstill. The zero value is entered now. 5 Put on the platform an accurate calibration weight. See table below. The available values in this program are dependent of the weighing capacity of the scale. Weighing capacity Choice of the type of scale calibration weight 300 g 100, 200, 300 g 600 g 200, 400, 500, 600 g 1200 g 500, 1000, 1200 g 1550 g 500, 1000, 1500 g 3100 g 1000, 2000, 3000 g The figures in this table indicated as fat will realise the best accuracy for that scale, in relation to the full weighing range. Make use of weights with sufficient accuracy, at least class M1. 6 Press key : as soon as the reading has come to a standstill. Now the available calibration values are show one after another on the display. 7 Press again key if the correct value is displayed. After a few seconds the calibration value is calculated and entered. The calibration procedure will terminate now automatically. The scale switches back to the weighing mode. Switch the scale off and on again.

page 11 Errors and reports After switching on Lod... stays displayed. The zero value is too low. Check the presence and correct position of the platform and carrier. Possibly the loadcell is damaged. Execute a complete calibration procedure. During the start up procedure the display shows for a longer time: SA 230. The scale is in motion (f.e. vibrations) or the value of the calibrated zero has been changed. Execute the Complete Weight Calibration procedure (pag. 10) up to (and included) point 4, in order to establish a new zero value. Switch off the scale and on again. Check the weighing accuracy with a accurate weight. If not correct, execute the Complete Calibration Procedure to the end (point 7). During the start up procedure the display shows: ol ( over load ). The weigh platform is loaded with a weight > 10% of the weighing capacity and will not set zero. Remove the load. Possibly the loadcell is damaged. The scale does not sets zero operating the zero key. However setting zero via the tare key is working. The weight value proves to be outside the zero limits (+ and - 2% of weighing capacity). Switch the scale off and on again, so a new zero value may be entered. Reading is gross negative. Zeroing and taring not possible. The scale has been switched on with a load on the platform and has set itself at zero with that load. The load has been removed and now the reading is gross negative and incorrect. Switch the scale off and on again with an empty weighing platform. The scale is loaded above its weighing capacity. Remove the overload. Possibly the loadcell is damaged. Shortly displayed after a quick calibration with a calibration weight that deviates more than 0,5% from the last adjustment. This quick calibration has not been entered. The scales switches back to the weighing mode immediately, with the previous adjustments. Execute a complete calibration procedure.

page 12 RS 232 comport Data communication (option) Tabel 1 1 lsb Byte Format msb 0 1 2 3 4 5 6 7 0 start stop Baud rate 2400 / 9600 settable Parity none Data bits 8 Codes CR and LF Connector DB-09 Male: Pin 1, 3, 4, 6, 7, 8, 9 Pin 2 Pin 5 NC TXD GND Tabel 2 String Format 12 bytes nr. 1 2 3 4 5 6 7 8 9 10 11 12 a x x x x b x x c g CR LF a = òr a blank, òr a minus sign x = blanks and/or weight figures (no preceding zero s) b = decimal dot *) (example of a scale with two figures after the dot) c = fixed blank g = weight unit: gram (with other units the string is longer) *) With other weighing capacities the position of the dot will be adapted to the number of figures after the dot.