1 Adam Equipment CPWplus RANGE OF SCALES (P.N. 9009, Rev. C, June 2008) Adam Equipment Company 2008
2 Adam Equipment Company 2008
3 CONTENTS 1.0 INTRODUCTION SPECIFICATIONS INSTALLATION UNPACKING LOCATING SETTING UP SETTING UP THE STANDARD CPWplus SERIES SETTING UP THE CPWplus M & CPWplus L SERIES KEYPAD DISPLAY SYMBOLS AND INDICATORS BATTERY BACKLIGHT AUTO POWER OFF OPERATIONS SWITCHING ON THE SCALE ZEROING TARING SELECTING THE UNIT WEIGHING RS-232 INTERFACE CALIBRATION PARAMETER SETTING USER PARAMETERS AUTO POWER OFF SETTING OF BACKLIGHT ENABLING OF UNITS COMMUNICATION ADDRESS SELECTION OF BAUD RATE SELECTION OF BIT RATE AND PARITY SELECTION OF TRANSMISSION MODE SELECTION OF HOLD FUNCTION SETTING OF HOLD TIME LIMIT TECHNICAL PARAMETERS FILTER ZERO TRACKING STABILIZATION RANGE STABILIZATION TRACKING FACTORY PARAMETERS ERROR MESSAGES REPLACEMENT PARTS AND ACCESSORIES SERVICE INFORMATION WARRANTY INFORMATION APPENDIX...28 Adam Equipment Company
4 Adam Equipment Company
5 1.0 INTRODUCTION The CPWplus range of Platform Scales has a stainless steel top pan on a steel frame and an indicator with a large backlit LCD. The waterresistant keyboard has 4 easy to use function keys: [On/Off], [Print/Hold], [Unit], and [Tare/Zero]. All scales are supplied with the Power Supply module. CPWplus 300 x 300mm base operates with 6 x AA size batteries CPWplus M 500 x 500mm base with internal rechargeable batteries CPWplus L 900 x 600mm base with internal rechargeable batteries Adam Equipment Company
6 2.0 SPECIFICATIONS Model CPWplus 35 CPWplus 35M CPWplus 35L CPWplus 75 CPWplus 75M CPWplus 75L CPWplus 150 CPWplus 150M CPWplus 150L CPWplus 200 CPWplus 200M CPWplus 200L CPWplus 300L Capacity x Readability d=e= 35 kg x 0.01kg 75 lb x 0.02 lb 1200 oz x 0.5 oz 74 lb:16 oz x 1 oz 75 kg x 0.02 kg 165 lbx 0.05 lb 2640 oz x 1 oz 164 lb:16 oz x 1 oz 150 kg x 0.05 kg 330 lb x 0.1 lb 5280 oz x 2 oz 329 lb:16 oz x 2 oz 200 kg x 0.05kg 440 lb x 0.1 lb 7040 oz x 2 oz 439 lb:16 oz x 2 oz 300 kg x 0.1kg 660 lb x 0.2 lb 10560oz x 5 oz 659 lb:16 oz x 5 oz Repeatability 0.01 kg / 0.02 lb 0.02 kg / 0.05 lb 0.05 kg / 0.1 lb 0.05 kg / 0.1 lb 0.1 kg / 0.2 lb Linearity 0.02 kg / 0.04 lb 0.04 kg / 0.1 lb 0.10 kg / 0.2 lb 0.10 kg / 0.2 lb 0.2 kg / 0.4 lb Series CPWplus CPWplus - M CPWplus - L Platform size 300 x 300 mm 500 x 500 mm 900 x 600 mm Power Option Power supply module supplied 12 VAC 150 ma 12 VDC 500 ma 12 VDC 500 ma 6 x AA size batteries Internal rechargeable battery (~ 60 hrs) Net weight 4 kg 8.5 kg 17 kg Indicator Dimensions (wxdxh) 220 x 95 x 43 mm Stabilization time 2-3 seconds Tare Full range tare by subtraction Weighing units kg, lb, oz, lb:oz Calibration Automatic External - user selectable cal weight Interface Bi-directional RS-232 Operating temperature 0 C to 40 C Humidity Up to 90% RH non-condensing Display 25 mm Backlit LCD digits with weight legends for kg, lb, oz, lb:oz and low battery, stable, zero, net weight and Hold symbols Keypad Mechanical switches under overlay Scale housing Indicator: Aluminium Platform: Mild steel base and stainless steel pan Applications Weighing, Dynamic / Animal weighing, Display Hold Adam Equipment Company
7 3.0 INSTALLATION 3.1 UNPACKING The scales come with- Standard CPWplus CPWplus Indicator with bracket and 2 screws The Platform Stainless Steel Pan Power supply Module An Instruction manual CPWplus M CPWplus Indicator with bracket and 2 screws The Platform Stainless Steel Pan Power supply Module An Instruction manual CPWplus L CPWplus Indicator with bracket and 2 screws The Platform Stainless Steel Pan Power supply Module An Instruction manual Adam Equipment Company
8 3.2 LOCATING The scales should not be placed in a location that will reduce the accuracy. Avoid extremes of temperature. Do not place the scale in direct sunlight or near air conditioning vents. Avoid unsuitable surfaces. The table or floor should be rigid and free from vibration. Avoid unstable power sources. Do not use the scale near large users of electricity such as welding equipment or large motors. Do not place the scale near vibrating machinery. Avoid high humidity that might cause condensation. Avoid direct contact with water. Do not spray or immerse the scales in water. Avoid air movement such as from fans or opening doors. Do not place the scale near open windows or air-conditioning vents. Keep the scales clean. Do not stack material on the scales when they are not in use. Adam Equipment Company
9 3.3 SETTING UP SETTING UP THE STANDARD CPWplus SERIES 1 Remove the parts from the packing carefully. Place the base on a rigid surface. Place the Stainless Steel pan on the base, if it not already assembled. 2 The indicator is separately packed and comes attached to a bracket with the help of two thumb screws. Bracket Thumb Screw To adjust the angle of the indicator, use the two thumb screws on the side of the bracket that connects the indicator. 3 Connect the cable attached to the base to the connector at the rear of the indicator. Tighten the ferrule to secure the cable. Connector on the Indicator 4 Power can be supplied using the adapter delivering 12 VAC 150 ma minimum or using batteries inside the scale unit (6 x AA size). Remove the cover from the battery compartment under the scale. Install six AA size batteries as shown below. The alkaline batteries are suggested for use for best life. Connector attached to the cable 6 X "AA" Alkaline Ferrule NOTE: When moving the scale, take care to prevent bending of the cable and connector too much as over a period of time this can weaken the wires in the connector and cause malfunction. MOUNTING THE INDICATOR- The indicator attached to the bracket can be mounted in the following 3 ways. To adjust the angle of the indicator, use the two thumb screws on the side of the bracket that connects the indicator. 1. Place it on the work bench- Simply place the indicator attached to the bracket on the work bench at an angle. 2. Attach it to the base of the scale- There are two thumb screws on the base (opposite to the Power input and RS-232 ports). Remove them from the base and use them to attach the bracket to the base. 3. Mount it on the wall- Use two suitable screws (not supplied) to fix the bracket to the wall. Adam Equipment Company
10 3.3.2 SETTING UP THE CPWplus M & CPWplus L SERIES 1 2 Remove the parts from the packing carefully. Place the base on a rigid floor. Place the Stainless Steel pan on the base, if it not already assembled. Level the base using the four adjustable feet. Adjustable feet For CPWplus L, place the optional rubber mat on the pan for animal weighing. 3 The indicator is separately packed and comes attached to a bracket with the help of two thumb screws. 4 Connect the cable attached to the base to the connector at the rear of the indicator. Tighten the ferrule to secure the cable. Connector on the Indicator Bracket Thumb Screw Connector attached to the cable Ferrule To adjust the angle of the indicator, use the two thumb screws on the side of the bracket that connects the indicator. The Indicator can be placed on any flat surface or mounted on the wall. NOTE: When moving the scale, take care to prevent bending of the cable and connector too much as over a period of time this can weaken the wires in the connector and cause malfunction. NOTE: To re-charge the internal battery, connect the power supply module to the rear of the indicator and apply power. Adam Equipment Company
11 4.0 KEYPAD [On / Off] Turns the scale on or off only [Print/Hold] Sends data via RS-232 and combines with Hold functions, if enabled [Unit] Selects kilograms, pounds, ounces or pounds-ounces [Tare/Zero] Sets the display to true zero or net zero by storing the current weight in the tare memory 5.0 DISPLAY 6.0 SYMBOLS AND INDICATORS Symbol 0 Description Scale is in the zero position Weighing result is stable kg, lb, oz or lb-oz : Net Hold Active weighing unit Battery is weak When weighing in pounds:ounces Net weight is being displayed Display is held as per the Hold parameter setting (See section 9.8 & 9.9) Adam Equipment Company
12 7.0 BATTERY CPWplus standard can be operated from 6x AA batteries, if desired. CPWplus-M and CPWplus-L scales have an internal rechargeable battery. When the battery needs charging a symbol on the display will turn on. The battery should be charged when the symbol is on. To charge the battery, connect the power supply module to the rear of the indicator and apply power. The scale need not be turned on. The battery should be charged for 12 hours for full capacity. The battery life is approximately 60 hours. 8.0 BACKLIGHT The backlight for the LCD can be set by the user to always off, always on or automatic (on only when the scale is in use or a key is pressed). See setting of the parameter in section AUTO POWER OFF The auto power off can be set by the user to disable the feature or to a pre-set time interval. See setting of the parameter in section Adam Equipment Company
13 10.0 OPERATIONS 10.1 SWITCHING ON THE SCALE To switch on the scale, press the [On/Off] key. The display will show the software revision number and then flash all the digits and symbols before counting down to zero. This ensures all LCD segments are working. The last active weighing unit will be displayed. The scale will turn off automatically to conserve battery life if the automatic turn off parameter is set (see section ). To turn off the scale press the [On/Off] key. A battery symbol will be on when the internal battery needs to be re-charged. Connect the power supply module to the rear of the indicator and switch on the mains ZEROING The ZERO and TARE function is combined into one key [Tare/Zero]. You can press the [Tare/Zero] key at any time to set a new zero point. Re-zeroing the scale may be necessary if a small amount of weight is still shown when the platform is empty. If the scale is less than 2% of the maximum capacity, pressing [Tare/Zero] will zero the scale. However, if the weight on the scale is more than 2%, pressing [Tare/Zero] will tare the scale. See the next section on taring the scale. The scale has an automatic zero tracking function to account for shifting of the zero point due to the environment change or accumulation of dust on the platform. Adam Equipment Company
14 10.3 TARING Zero the scale by pressing the [Tare/ Zero] key if necessary. The zero indicator will be on. Place a container on the platform, a value for its weight will be displayed. Press the [Tare/Zero] key to tare the scale. The weight that was displayed is stored as the tare value. This value is subtracted from the display, leaving zero on the display. The indicator Net will be on. As a product is added to the container, only the weight of the product will be shown. The scale could be tared a second time if another type of product was to be added to the first one. Again only the weight of the product that is added after taring will be displayed. When the container is removed a negative value will be shown. If the scale was tared just before removing the container, this value is the gross weight of the container plus all products. The zero indicator will also be on because the platform is back to the same condition as it was when the [Tare/Zero] key was pressed last. Note: If the capacity of the scale is 6000g and a container weighing 2450g is used and tared, the scale can then be used to weigh the material of up to 3550g. Adam Equipment Company
15 U U 10.4 SELECTING THE UNIT To select the weighing unit press the [Unit] key to move form one unit to another. The weighing unit must be enabled by the users beforehand (see section ). If a unit is disabled it cannot be selected by using the [Unit] key WEIGHING When the scale is at zero, place an item to be weighed on the platform. The display will show the weight in the unit selected previously. The weighing result can be viewed in other enabled units using the [Unit] key. If a container is used, this can be tared as described in The scale then shows the net weight of the material added RS-232 INTERFACE The CPWplus scales come with a bi-directional RS-232 interface. Interface parameters are: RS-232 output of weighing data ASCII code Selectable Baud Selectable data bits Selectable Parity UConnection details are: Connector: 9 pin D-subminiature socket Pin 3 Output Pin 2 Input Pin 5 Signal Ground Normal OutputU: (See section ) add: A G/W: kg <cr><lf> <cr><lf> <cr><lf> add: A N/W: kg <cr><lf> <cr><lf> <cr><lf> G/W is Gross Weight N/W is Net weight UContinuous OutputU: (See section ) ASNG/W xx ASNG/W xx ASNG/W xx <cr><lf> A is communication address set by the user, S stands for stable, N for no error G/W for gross weight, xx for the chosen unit Adam Equipment Company
16 The scale can be controlled by a computer using the following commands. The commands must be sent in upper case letters, i.e. T and not t. The input and output formats are as given below. Input commands format: Z <cr> <lf> H <cr> <lf> N <cr> <lf> G <cr> <lf> T <cr> <lf> Tares the scale to display the net weight- same as pressing [Tare/Zero] Sets the scale to hold if the hold function is enabled. Same as pressing the [Hold] key Sends the net weight to the RS-232 interface. Sends the gross weight to the RS-232 interface. Sends the tare weight to the RS-232 interface. Output format: G kg <cr><lf> N kg <cr><lf> Adam Equipment Company
17 12.0 CALIBRATION PROCEDURE Occasionally the scale should be verified whether it is weighing correctly by measuring to a known mass. Zero the scale. Place the mass on the centre of the platform and note the reading. Calibrate the scale, if necessary. While in the normal weighing mode, press and hold the [Tare/Zero] key for 4 seconds. The display will show CAL along with the last selected unit. The unit can be changed by using the [Unit] key to calibrate in kg or lb. Press the [Print/Hold] key. The display will show L xx where xx is the Calibration weight which is user-selectable. Use the [Tare/Zero] key to change the flashing digit and the [Print/Hold] key to move to the next digit. Press the [Unit] key to confirm the calibration weight. The digit stops flashing. Note: If the selected mass is less than 10% of the capacity of the scale, an error message CALEr will be displayed and the scale will return to zero. Repeat the process correctly. Adam Equipment Company
18 Place the correct calibration mass as selected by the user at the centre of the pan. Press the [Unit]. The display will return to weighing mode. Note: If the mass loaded is more than ±20% of the factory calibration reference then an error message CALEr will be displayed and the scale will return to weighing without calibration being saved. Repeat the process correctly. Remove the weight. Verify the scale is calibrated correctly. Repeat the process, if necessary PARAMETER SETTING 13.1 USER PARAMETERS The scale can be set as desired by the user to control the weighing operation. See section 18.0 for the complete list of parameters. Switch off the scale. Hold the [Tare/Zero] key and then press the [On/Off] key momentarily. Release the [Tare/Zero] key. The display shows the first parameter - auto power off. To exit the parameter setting at any time, press the [Print/Hold] key. To scroll through the user parameters, press the [Unit] key (which will advance to the next parameter). To return to normal weighing, turn the scale off and back to on again or press the [Print/Hold] key. Adam Equipment Company
19 AUTO POWER OFF The first parameter is to set the auto power off function. The display will show Pr off (DEFAULT SET). Press [Tare/Zero] to toggle between Pr on and Pr off. Enables the Auto Power Off function. The power will be turned off after 2 minutes if a key has not been pressed for 2 minutes and the scale is at zero. If there is any weight on the scale or a key is pressed, the scale will continue to work. Disables the Auto Power Off function. The scale will not automatically turn off. Press the [Unit] key to confirm the selection and move to the next parameter SETTING OF BACKLIGHT The second parameter to set the backlight function. Display will show bl 3 (DEFAULT SET). Press the [Tare/Zero] key to change the settings Off- backlight is switched off always On- backlight is set to on always Automatic- backlight will be off unless a weight is placed on the pan. When the weight is removed it will stay on for 10 seconds after the scale returns to zero. Press the [Unit] key to confirm the selection and move to the next parameter. Adam Equipment Company
20 ENABLING OF UNITS The third parameter is to enable or disable the weighing units so that the user can select the enabled units during the weighing operation. Display will show on kg (DEFAULT SET) Use [Tare/Zero] to toggle between on and off. Enables the unit Disables the unit Press the [Unit] key to confirm the selection and move to the next unit which is lb. After all units are set, press the [Unit] key to move to the next parameter COMMUNICATION ADDRESS The fourth parameter is for setting the ID for the RS-232 results output. Display will show Add 0 (DEFAULT SET) This parameter sets the communication address which is sent via RS-232 as an ID code. There are 26 options to select from Add 0 to Add 25. Set Add 0 for no address. The numbers relate to alphabets for example 1=A, 2=B to 25=Y Use the [Tare/Zero] key to scroll through the options. Press the [Unit] key to confirm the selection and move to the next parameter. Adam Equipment Company
21 SELECTION OF BAUD RATE The fifth parameter is to select the baud rate per second which is the speed of sending data to RS-232 interface. Display will show b 9600 (DEFAULT SET) Use the [Tare/Zero] key to scroll through the options. There are three options- Press the [Unit] key to confirm the selection and move to the next parameter SELECTION OF BIT RATE AND PARITY The sixth parameter is to select the bit rate and parity used for sending data to RS-232 interface. Display will show PAr 1 (DEFAULT SET) 8 bits no parity 7 bits even parity 7 bits odd parity Use the [Tare/Zero] key to scroll through the options. Press the [Unit] key to confirm the selection and move to the next parameter. Adam Equipment Company
22 SELECTION OF TRANSMISSION MODE The seventh parameter is to select the transmission mode. Display will show trn 1 (DEFAULT SET). See the HOLD AND PRINTING TABLE in section No data output Continuous data output Normal output when the [Print/Hold] key is pressed Use the [Tare/Zero] key to scroll through the options. Press the [Unit] key to confirm the selection and move to the next parameter SELECTION OF HOLD FUNCTION The eighth parameter is to set the Hold function. Display will show Hod 1 (DEFAULT SET). See the HOLD AND PRINTING TABLE in section No hold function Automatic hold function Manual hold function Use the [Tare/Zero] key to scroll through the options. If selection of Hod 2 or Hod 3 is made then it will lead to SETTING OF HOLD TIME LIMIT (see section ). The display will show Hold above the weight during operation. Adam Equipment Company
23 If Hod 1 is selected, pressing the [Unit] key will take you back to the first parameter on Auto Power Off. If you want to return to weighing, press the [Print/Hold] key SETTING OF HOLD TIME LIMIT This parameter is to set the time limit by which the display is held after the hold function is used. It is applicable if the hold function is set to Hod 2 or Hod 3. Use the [Tare/Zero] key to scroll through the options. The options are- Holds the display for an infinite time limit Holds the display for 15 (1 x 15) seconds Holds the display for 30 (2 x 15) seconds Holds the display for 45 (3 x 15) seconds Holds the display for 60 (4 x 15) seconds Press the [Unit] key to confirm the selection and move back to the first parameter or press [Print/Hold] to exit the parameter setting. Adam Equipment Company
24 HOLD AND PRINTING TABLE trn 1 trn 2 trn 3 Hod 1 RS-232 is off. Hold is off. [Print/hold] key has no function. Prints continuously. Hold is off. [Print/hold] key has no function. RS-232 prints when [Print/Hold] is pressed. Hold function is disabled. Hod 2 Hod 3 RS-232 is off. Hold occurs automatically when the weight is stable. Hold is released if [Print/Hold] is pressed or time expires as per Hti setting. RS-232 is off Hold occurs when the [Print/Hold] key is pressed. Hold is released if [Print/Hold] is pressed again or time expires as per Hti setting. Print continuously. Hold occurs automatically when the weight is stable. Hold is released if [Print/Hold] is pressed or time expires as per Hti setting. Print continuously. Hold occurs when the [Print/Hold] key is pressed. Hold is released if [Print/Hold] is pressed again or time expires as per Hti setting. RS-232 prints and hold occurs automatically when the weight is stable. [Print/Hold] key is pressed print will occur again. Hold function is released if the key is pressed again or time expires as per Hti setting. RS-232 prints and the hold occurs when [Print/Hold] is pressed. If [Print/Hold] is pressed a second time print will occur again. Hold is released if [Print/Hold] is pressed again or time expires as per Hti setting TECHNICAL PARAMETERS The technical parameters allow adjusting of the scale for accuracy and speed. See section 18.0 for the complete list of parameters. Switch off the scale. Hold the [Unit] key and then press [On/Off] momentarily. Release the [Unit] key. The display shows the first technical parameter to set the filter Fi x. To exit the parameter setting at any time, press the [Print/Hold] key. To scroll through the technical parameters, press the [Unit] key (which will advance to the next parameter). To return to normal weighing, turn the scale off and back to on again or press the [Print/Hold] key. Adam Equipment Company
25 FILTER This parameter is for setting the speed of the display filter. For poor environments the filter should be set at its slowest to minimise external influences on the scale. For weighing small samples or gradual filling, the filter should be set at a faster setting. Press [Tare/Zero] to scroll through the options. The display will show Fi 1 to Fi 3. If it is set to F1 1 then the display is at its slowest setting and at F1 3 the display is in its fastest setting. Press [Unit] to confirm the selection and move to the next parameter ZERO TRACKING This parameter is for setting the range of the zero tracking. Zero tracking will aid the scale to hold or return to zero and should be increased if large weights are left on the scale or temperature is not consistent. Press [Tare/Zero] to scroll through the settings. The display will show ZEo 1 to ZEo 8. If it is set to ZEo 1 the zero tracking is at its smallest range and ZEo 8 the highest. Press [Unit] to confirm the selection and move to the next parameter STABILIZATION RANGE This parameter is for setting the range of the stability indicator. This is used to determine when the scale will print automatically as well as indicate that the weight is stable. Adam Equipment Company
26 Press [Tare/Zero] to scroll through the settings. The display will show StA 1 to StA 8. If it is set to StA 8 then the stability is at its fastest and StA 1 the slowest. Press [Unit] to confirm the selection and move to the next parameter STABILIZATION TRACKING This parameter is for setting the size of the tracking range to indicate the stability. This is used to stable the scale once a weighing result is achieved. Press [Tare/Zero] to scroll through the settings. The display will show Str 1 to Str 5. If it is set to Str 1 then the stability range is at its smallest and Str 5 the highest. When the desired value is displayed, press the [Print/Hold] key to select the value and exit the Technical Parameters. The display will count down to zero and the scale will return to normal weighing. If [Unit] is pressed instead of the [Print/Hold] key, the display will ask for Pin for entering into the Factory Parameters. Switch off the scale. Switch on the scale to start the operation FACTORY PARAMETERS If after the last Technical Parameter [Unit] key is pressed, the scale will advance to the Factory Parameter section. This section contains critical calibration reference information and is protected by a Pin Code which can only be accessed by a qualified technician. To exit, the user must switch off the scale when the display shows Pi. Adam Equipment Company
27 14.0 ERROR MESSAGES During the initial power-on testing or during the operation the scale may show an error message. The error messages are described below. ERROR CODE DESCRIPTION POSSIBLE CAUSES A continuous beep is heard. If the selected mass is less than 10% or more than 20% of the capacity of the scale, an error message CALEr will be displayed and the scale will return to zero. Weight on the pan exceeds the capacity of the scale. Remove the weight from the pan. Incorrect calibration mass. Repeat the process correctly. If an error message is shown, repeat the procedure that caused the message such as turning the scale on, calibration or any other functions. If the error message is still shown, contact your supplier for further support REPLACEMENT PARTS AND ACCESSORIES If you need to order any accessories and spare parts, contact your dealer or Adam Equipment. A partial list of such items is as follows- Accessories Part Number Hard carry case (For Standard CPWplus 7954 models only) Printer 8023 RS-232 cable 9014 Non-slip mats (For CPWplus L models only) 9013 Spare Parts Part Number Power Supply Adapter 7973 Keypad overlay 7960 Stainless Steel Pan for CPWplus 7972 Stainless Steel Pan for CPWplus M 9011 Stainless Steel Pan for CPWplus L 9010 Replacement Lead-Acid Battery for 9012 CPWplus M & CPWplus L Adam Equipment Company
28 16.0 SERVICE INFORMATION This manual covers the details of operation. If you have a problem with the scale that is not directly addressed by this manual then contact your supplier for assistance. In order to provide further assistance, the supplier will need the following information which should be kept ready: A. Details of your company -Name of your company: -Contact person s name: -Contact telephone, , fax or any other methods: B. Details of the unit purchased (This part of information should always be available for any future correspondence. We suggest you to fill in this form as soon as the unit is received and keep a print-out in your record for ready reference.) Model name of the scale: CPWplus Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase: Name of the supplier and place: C. Brief description of the problem Include any recent history of the unit. For example: -Has it been working since it s delivered -Has it been in contact with water -Damaged from a fire -Electrical Storms in the area -Dropped on the floor, etc. Adam Equipment Company
29 17.0 WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company. The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems. However, any freight involved in sending the faulty units or parts to the service centre should be borne by the purchaser. The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed. All claims are at the sole discretion of Adam Equipment. This warranty does not cover equipment where defects or poor performance is due to misuse, accidental damage, exposure to radioactive or corrosive materials, negligence, faulty installation, unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual. Repairs carried out under the warranty does not extend the warranty period. Components removed during the warranty repairs become the company property. The statutory right of the purchaser is not affected by this warranty. The terms of this warranty is governed by the UK law. For complete details on Warranty Information, see the terms and conditions of sale available on our web-site. Adam Equipment Company
30 18.0 APPENDIX Adam Equipment Company
31 Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards, following the provisions of the below stated directives: FCC COMPLIANCE Electro Magnetic Compatibility Directive 89/336/EEC Low Voltage Directive 73/23/EEC Adam Equipment Co. Ltd. Bond Avenue, Denbigh East Milton Keynes, MK1 1SW United Kingdom This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment. WEEE COMPLIANCE Any Electrical or Electronic Equipment (EEE) component or assembly of parts intended to be incorporated into EEE devices as defined by European Directive 2002/95/EEC must be recycled or disposed using techniques that do not introduce hazardous substances harmful to our health or the environment as listed in Directive 2002/95/EC or amending legislation. Battery disposal in Landfill Sites is more regulated since July 2002 by regulation 9 of the Landfill (England and Wales) Regulations 2002 and Hazardous Waste Regulations Battery recycling has become topical and the Waste Electrical and Electronic Equipment (WEEE) Regulations are set to impose targets for recycling. Adam Equipment Company 2008
32 ADAM EQUIPMENT is an ISO 9001:2000 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment. Adam products are predominantly designed for the Laboratory, Educational, Medical, retail and Industrial Segments. The product range can be described as follows: -Analytical and Precision Balances -Compact and Portable Balances -High Capacity Balances -Moisture analysers / balances -Mechanical Scales -Counting Scales -Digital Weighing/Check-weighing Scales -High performance Platform Scales -Crane scales -Medical Scales -Retail Scales for Price computing For a complete listing of all Adam products visit our website at Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment. Adam Equipment reserves the right to make changes to the technology, features, specifications and design of the equipment without notice. All information contained within this publication is to the best of our knowledge timely, complete and accurate when issued. However, we are not responsible for misinterpretations which may result from the reading of this material. The latest version of this publication can be found on our Website. Adam Equipment Company 2008
HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0
HIGH PRECISION BALANCE MWP OWNER S MANUAL MWP-2004-12 ver.1.0 INTRODUCTION------------------------------------------------1 1. INSTALLATION---------------------------------------------------2 Unpacking---------------------------------------------------------------2
XP Series Balances Operation Manual
XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business
SATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND
- Manual SATEX SA 230 PRECISION BALANCE Weegtechniek holland b.v. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND Tel. + 31 36 522 20 30 Fax. + 31 36 522 20 60 Email [email protected] Website www.satex.nl page
Operating Manual Electronic Wheelchair Scale with cable display M50610
Operating Manual Electronic Wheelchair Scale with cable display M50610 ADE GmbH & Co. Hammer Steindamm 27 29 D 22089 Hamburg Germany +49(40)432776-0 Fax +49(40)432776-10 E-mail: [email protected] Contents
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION
Calibration Guide PREPARATION Adventurer Pro Adventurer Pro balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
Weather Radio Alarm Clock
1200093 User s Guide Weather Radio Alarm Clock Thank you for purchasing your Weather Radio Alarm Clock from RadioShack. Please read this user s guide before installing, setting up, and using your new weather
BW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
High precision counting scale. Operation Manual. l RCZ-A Series
High precision counting scale Operation Manual l RCZ-A Series TABLE OF CONTENTS I. PRECAUTIONS BEFORE USING THE SCALE 1 II. EXPLANATION OF DISPLAY SYMBOLS 2 III. KEYPAD FUNCTIONS 4 IV. OPERATIONS 5 SWITCH
PA Series Precision Analytical Balances USER MANUAL
PA Series Precision Analytical Balances USER MANUAL (Software Revision: 2.35) Page 2 of 32 Page 3 of 32 CONTENTS 1.0 INTRODUCTION...4 2.0 TECHNICAL SPECIFICATIONS...5 3.0 UNPACKING THE BALANCE...6 4.0
User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual RK-2d / RK-2t 1U Short Depth Keyboard Drawer Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October
=============================== WARNING
=============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that
Wireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
Solar Weather Station Model: BAR806 / BAR806A
Solar Weather Station Model: BAR806 / BAR806A EN CONTENTS USER MANUAL Overview... 2 Front view... 2 Back view... 3 Remote sensor... 3 Getting started... 3 Solar panel... 3 Insert batteries... 4 Remote
SMART Board 8055i and 8055i-SMP
SMART Board 8055i and 8055i-SMP Interactive flat panel Installation guide Product registration If you register your SMART product, we ll notify you of new features and software upgrades. Register online
Model 349KLX Remote Display Digital Scale User Instructions
Model 349KLX Remote Display Digital Scale User Instructions P/N UM349KLX Rev 3-080713 1 Model 349KLX Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully,
Magnetic Stripe Reader-Writer. Magnetic Stripe Reader-Writer. RS232 & USB-RS232 Interface Quickstart Manual
Magnetic Stripe Reader-Writer RS232 & USB-RS232 Quickstart Manual ID TECH 10721 Walker Street Cypress, California 90630 (714) 761-6368 www.idtechproducts.com 80058504-002 Rev. C R01/08 Magnetic Stripe
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
MagIC 6100. Installation Manual. Point of Sales Terminals TD06014B
MagIC 6100 Installation Manual Point of Sales Terminals TD06014B Contents Description 3 Introduction 3 Presentation of the MagIC 6100 terminal 3 Technical Data 4 Installation 5 Unpacking 5 Safety recommendations
Instruction Manual FL
3. Operation Overview The most common used features (such as displaying force, peak hold, zero and changing of displayed units) can all be done by pressing a single dedicated key identified on the front
Ingenico. User Guide 5100M. Secure transaction and payment solutions
User Guide Ingenico 5100M Secure transaction and payment solutions Ingenico 5100 M Contents 1 Presentation... 5 1.1 Overview of Ingenico 5100... 6 1.2 Keyboard details and functionality... 7 2 Use...
Model 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3
AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3 2008 Hamlet Video International Ltd. All rights reserved This handbook contains proprietary information of Hamlet Video International
Laser Barcode Scanner
Laser Barcode Scanner User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
Temp. & humidity Transmitter Instructions
Temp. & humidity Transmitter Instructions AQ3485/AQ3485Y www.aosong.com 1 Product Overview AQ3485/ AQ3485Y outdoor network temperature and humidity transmitter is accurate measurement of relative humidity
User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch
User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch Rev: 1.1.0 7106503251 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide
GB05-6 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2012 In the interests of development, information
ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE
PR E C I S I O N ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE Download Rates at WWW.PELOUZE.COM MODEL PS5DL 5 lb. Capacity Small/Large Packages OPERATOR S MANUAL Please take a few minutes to
DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product
DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual Please read carefully before using this product 15 1 Table of Contents 1 Table of Contents... 16 2 Safety Instructions:... 17 3 Specification:...
User manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
2100 POS System. 2100 User Guide
2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100
User s Manual. Bluetooth Calculator Keypad. Page
User s Manual Bluetooth Calculator Keypad Page Regulatory Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
Manual. Simrad StructureScan LSS-1 Sonar Module. English
Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the
DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:
PR100/PR300/PR500 Pressure Logger Operation Contents: Product Applications and Useful Features Product Specifications Operating Instructions / Getting Started DicksonWare Software Specifications Product
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
INSTRUCTION MANUAL FOR FP ratemail SCALE
INSTRUCTION MANUAL FOR FP ratemail SCALE 1 INDEX Installation Operation Weight Indication Mode Postage Value Indication Mode Parcelforce International Add-on Services Parts Counting Mode Franking Machine
IFS SP-PoE Splitter User Manual
IFS SP-PoE Splitter User Manual P/N 1069176-EN REV 1.01 ISS 01JUL10 2011 UTC Fire & Security. All rights reserved. Content Overview 2 Package contents 2 Introduction 3 Product Specifications 3 Hardware
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
OPERATOR S Manual All specifications are subject to change without notice
OPERATOR S Manual All specifications are subject to change without notice Warning - U.S. This equipment has been tested and founded to comply with the limits for a Class A digital device pursuant to Part
Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10
Business Audio System: Music & Messaging MP3 Player by Grace Digital Audio User Guide Model No. GDI-USBM10 User Guide Contents Introduction 2 Safety & General Use Information 2 Features 3 Set Up & Operation
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
WIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
Laser Barcode Scanner User s Manual
Laser Barcode Scanner User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
ISO 9002 Certified Lead with technology Win customers with service. Magnetic Stripe Reader SERIES 1260 OPERATION MANUAL
ISO 9002 Certified Lead with technology Win customers with service Magnetic Stripe Reader SERIES 1260 OPERATION MANUAL 1 2 Jarltech International Inc. 1998. All rights reserved. Under the copyright laws,
Mini Portable Reader (MPR) Model HS 5900L F
Mini Portable Reader (MPR) Model HS 5900L F TABLE OF CONTENTS Chapter 1: Mini Portable Reader (MPR) Basics 1 1.1 Preparing for Operation 1 1.2 Installing/Changing Batteries 1 1.3 Scanning with the Mini
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks
Forklift/Pallet Jack Scales Table of Contents
Forklift/Pallet Jack Scales Table of Contents CLS-420 Wired Version...308 CLS-420 Wireless Version...311 CLS-920i Wired Version...314 CLS-920i Wireless Version...317 Intercomp PW800...320 Pallet Truck
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
E&P HYDRAULICS Remote control EPRC-01 Level System Camper
USER S GUIDE E&P HYDRAULICS Remote control EPRC-01 Level System Camper 1 Copyright 2012, E&P Hydraulics This manual is copyrighted, with all rights reserved. Under the copyright laws, this may not, in
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI
American Weigh Scales, Inc. CQ-Series Digital Pocket Scale 7 4 1 0. 8 9 5 6 2 3 x = - CALI + CALC MODE M CAL AC CE % TARE OFF ON MC MR CQ-350 (350x0.1g) CQ-500 (500x0.1g) User Manual CQ-Series Manual Thank
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
CONTIENTS. 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3
CONTIENTS 2008.4 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3 4. PANEL LAYOUT----------------- 4 5. BUTTON FUNCTIONS------------- 5 6. OPERATING
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
User Guide Microsoft Screen Sharing for Lumia Phones (HD-10)
User Guide Microsoft Screen Sharing for Lumia Phones (HD-10) Issue 1.1 EN User Guide Microsoft Screen Sharing for Lumia Phones (HD-10) Contents Safety 3 About your accessory 4 Keys and parts 5 Connect
Atomic Alarm Clock model 13131W2
Instruction Manual Atomic Alarm Clock model 13131W2 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Atomic Clock... 5 Set
Installation guide H-5500-8554-03-A. HSI hardwired system interface
Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any
Usage, Installation, Warranty and Service Information
T13C Table Updater for Seating Management U S E R M A N UA L Usage, Installation, Warranty and Service Information Long Range Systems, LLC 4550 Excel Parkway, Suite 200 Addison, TX 75001 800.437.4996 www.lrsus.com
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
SMART Board 8070i-SMP and 8070i
SMART Board 8070i-SMP and 8070i Interactive flat panel Installation guide Product registration If you register your SMART product, we ll notify you of new features and software upgrades. Register online
Portable Satellite TV Antenna. VQ1000 Owner s Manual
Portable Satellite TV Antenna VQ1000 Owner s Manual Model VQ1 Solutions for Mobile Markets 11200 Hampshire Avenue South, Bloomington, MN 55438-2453 Phone: (952) 922-6889 Fax: (952) 922-8424 20963 REV E
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
MoCA Adapter MC1001 v2 Installation Guide
Technical Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of your product and use it to register your product at www.netgear.com/register.
ST815 Illumination Sensor with LCD
ST815 Illumination Sensor with LCD The Illumination Sensor with LCD (refer to as Illumination Sensor hereafter) is a Z-Wave TM enabled device which is fully compatible with any Z-Wave TM enabled network.
Instruction Manual Crane Scales PCE-HS Series
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 [email protected] PCE Instruments UK Ltd. Units 12/13 Southpoint Business
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
Vibrating Alarm Clock VAC500
Vibrating Alarm Clock VAC500 Keep this user guide for future reference. Always retain your proof of purchase in case of warranty service and register your product on line at: AUSTRALIA: www.oricom.com.au
User checks and maintenance of laboratory balances
Technical Note 13 March 2014 Issued: July 1995 Amended and reissued: July 2005, July 2007, October 2007, May 2010, March 2013, March 2014 User checks and maintenance of laboratory balances Copyright National
User's Guide. Pinless Moisture Meter. Model MO257
User's Guide Pinless Moisture Meter Model MO257 Introduction Congratulations on your purchase of the Extech MO257 Pinless Moisture Meter. The pinless moisture sensor monitors the moisture in wood and other
Industrial Balances PREMIUM Series 490 IBK/ITK/ISK
SWISS MADE Industrial Balances PREMIUM Series 490 IBK/ITK/ISK Precision Industrial Scales PREMIUM Series 490 IBK/ITK/ISK The Precisa 490 Series range of industrial scales stands for outmost Swiss precision.
OCSM Series. High Resolution Digital Crane Scale. User Guide
OCSM Series High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 3 5. Display & Keys... 3 Scale & Remote Keys... 3 Indicators... 4 Message...
2013 VTech Printed in China 91-009656-000 US
Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready
DMX USB PRO. User Manual. www.enttec.com
DMX USB PRO User Manual www.enttec.com Firmware V1.43 February 2007 Package Contents Your DMX USB PRO package should contain these items: DMX USB PRO (Part No. 70304) Driver for Windows software on the
USB/RS485 converter cable, complete
USB/RS485 converter cable, complete Instructions for use Contents Deutsch 1 Intended use 3 2 Safety 3 2.1 Safety information... 3 2.2 General information... 3 3 Description 5 3.1 Overview... 5 3.2 Connection
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C
/Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE
EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE User manual v1.5 Compatible with: ESIM264 v7.09.02 and up. ESIM364 all versions. Main features: Hardwired zone expansion adding 16 additional zones per
DAB Radio. Instruction Manual L55DAB10
DAB Radio Instruction Manual L55DAB10 L55DAB10_IB_110810_Zell.indd 1 L55DAB10_IB_110810_Zell.indd 2 Contents Unpacking...5 Product Overview...6 Top View... 6 Rear View... 6 Power Source...7 Battery Power...
Dome Security Camera with IR night vision
Dome Security Camera with IR night vision EN INSTRUCTION MANUAL 1 Before you begin Limited Warranty Terms & Conditions Swann Communications warrants this product against defects in workmanship and material
UK s best selling phone brand. User Guide. BT Decor 2200 Corded Phone
UK s best selling phone brand User Guide BT Decor 2200 Corded Phone 2 This User Guide provides you with all the information you need to get the most from your phone. Before you make your first call you
External Hard Drive esata & USB 2.0 Combo. User Guide English
External Hard Drive esata & USB 2.0 Combo User Guide English Contents Introduction 3 Controls, Connectors and Indicators 3 Front Panel Area 3 Rear Panel Area 3 About the Hard Drive 4 Locating the Drive
Refer to page 6 to page 19 for detailed instructions.
CODE:GZ0000297065 Refer to page 6 to page 19 for detailed instructions. Preface This manual describes the operation of the COMPACT CONDUCTIVITY METER, B-771. Be sure to read this manual before using the
ELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES
ELECTRONIC COUNTING SCALE Operation Manual l JCS- A SERIES CONTENTS I. Specification:... II. Operation:... III. Weight calibration:... IV. RS232 transmission confer Data format (optional) V. Regular trouble
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
M O D U L E - 7 E Model CS-Caliprompter Operator s Manual
O P E R A T I O N S A N D P R O C E D U R E S F O R C S - C A L I P R O M P T E R A N D A C C E S S O R I E S Model CS-Caliprompter Visual screen display allows easy step-by-step operation On-site programming
DAB & FM RADIO Installation Manual
Size: 105x145mm 105g copper paper DAB & FM RADIO Installation Manual Model: 10798 10799 10800 10801 Thank you for purchasing this AGK DAB/FM radio. Please read the instructions and warnings carefully before
User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.
16 channel wireless digital TC slate 1 Copyright BETSO ELECTRONICS Ltd. Contents 1. Product description...3 2. Top features...3 3. Control elements...4 4. Insertion of batteries / accumulators...6 5. External
SP-1700 OWNERS MANUAL
SP-1700 OWNERS MANUAL www.visionaudiovisual.com/techaudio/sp-1700 1 DECLARATION OF CONFORMITY Where applicable Vision products are certified and comply with all known local regulations to a CB Certification
BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:
BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960 This manual covers installation and operation procedures for BNC AM members: Berkeley Nucelonics - 2955 Kerner Blvd. San Rafael, CA 94901 - (415)453-9955 -