PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION
|
|
- Jordan Holland
- 8 years ago
- Views:
Transcription
1 Calibration Guide PREPARATION Adventurer Pro Adventurer Pro balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the scale is level, stable, and undisturbed during calibration. (Otherwise the process could fail.) Allow scale to warm up for five minutes after stabilizing to room temperature. Use suitable calibration masses (available from Ohaus). Exact weight value depends on model. Follow prompts for indicated values to use. (Weight values here are examples only.) Calibration may be locked out. To unlock it, use the Unlock menu. If the scale is set to Legal for Trade operation, a seal must be broken to unlock it. (See the Instruction Manual.) Note: To cancel calibration, press: INTERNAL CALIBRATION (No external weight needed.) 1 1 When calibration finishes, balance returns to currently selected mode. SPAN CALIBRATION (If InCal appears press No.) 1 1 (Acquiring zero value) 1 (Place weight on pan.) (If SPAN DONE flashes, remove mass from Pan.) (Press No to change.) Balance returns to weighing mode. Ohaus Corporation i Adventurer Pro Calibration Guide
2 Adventurer Pro Calibration Guide LINEARITY CALIBRATION: (If InCal appears press No.) 1 1 (Acquiring zero value) (Place weight on pan.) (Flashes while establishing weight value.) (Place weight on pan.) (Flashes while establishing weight value.) Remove weight from pan, and press: *80230* P/N Adventurer Pro Calibration Guide ii Ohaus Corporation
3 Calibration Guide CS Series Scales PREPARATION CS Scales can be calibrated as follows. Follow the prompts for calibration mass values. Ensure that the scale is level, stable, and undisturbed during calibration. (Otherwise the process could fail.) Allow scale to warm up for five minutes after stabilizing to room temperature. Use suitable calibration masses (available from Ohaus). Note: To cancel calibration, long-press: CALIBRATION 1 (Acquiring zero value) CAL -C- (Place weight on pan.) 1 C 200 -C- If calibration successful: PASS If calibration fails: CAL E If CAL E appears, turn the scale off and try again. Be sure to have the appropriate calibration weight. *802303* P/N Ohaus Corporation i CS Series Scales Calibration Guide
4 Calibration Guide Pioneer Balances PREPARATION Pioneer balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the scale is level, stable, and undisturbed during calibration. (Otherwise the process could fail.) Allow scale to warm up for five minutes after stabilizing to room temperature. Use suitable calibration masses (available from Ohaus). Exact weight value depends on model. Follow prompts for indicated values to use. (Weight values here are examples only.) Calibration may be locked. To unlock it, use the Unlock menu. (See Instruction Manual.) Note: To cancel calibration, press: until scale turns off. INTERNAL CALIBRATION (No external weight needed.) (Two screens flash alternately.) (Flashes continuously while calibration proceeds.) Balance returns to weighing mode. SPAN CALIBRATION (If InCal appears press No.) 1 1 (Place weight on pan.) (Press No to choose alternate weight.) (Remove the mass from the Pan.) Balance returns to weighing mode. done Ohaus Corporation i Pioneer Balances Calibration Guide
5 Pioneer Balances Calibration Guide LINEARITY CALIBRATION: (not available on InCal models) (If InCal appears press No.) 1 (Place weight on pan.) (Remove the mass from the Pan.) (Acquiring zero value) (Place weight on Pan.) (Remove the mass from the Pan.) (Recalculating zero value) done Balance returns to weighing mode. * * P/N Pioneer Balances Calibration Guide ii Ohaus Corporation
6 Quick Start Guide PREPARATION FOR USE Release Shipping Lock on top of the balance Turn the pointer 90 counter-clockwise. Install the Platform Rectangular platform: Place diagonally on subplatform and rotate counter-clockwise until it locks. Round platform: Set straight down on subplatform. Scout Pro Balance Locked position Pointer Unlocked position Subplatform Draft Shield models: Position draft shield on top and rotate it until it faces forward. Connect Power Adapter jack Ensure voltage identification label matches local line voltage. If not, do not connect the unit. Contact Ohaus or your dealer. Battery Installation Install the Four AA batteries with polarity as shown in the battery compartment. Balances with leveling feet and bubble must be leveled before using. (Bubble is at rear, next to AC Adapter Input Jack.) SELECTING THE LOCATION: Place on a firm, steady surface with sufficient space. Avoid excessive air current, vibrations, heat sources, or rapid temperature changes. SAFETY PRECAUTIONS Before plugging in the balance, verify that local power supply matches voltage printed on power adapter. (Use only the adapter provided with the balance.) Disconnect the balance from the power supply when cleaning. Do not operate this product in hazardous or unstable environments. Do not drop loads on the pan. Use only approved accessories and peripherals, as available. Operate the product only under ambient conditions specified in the Instruction Manual. Service should be performed by authorized personnel only. Ohaus Corporation i Scout Pro Balance Quick Start Guide
7 Scout Pro Balance Quick Start Guide CONTROLS Battery charge indicator Symbols for weighing modes: G Specific Gravity N Newtons % Percent PC Pieces kg Kilograms, g grams dwt (not used) lb:oz (not used) ct (not used) t Totalize mode (or taels*) *Unit varies by model Stability indicator Button ON/ZERO Off PRINT Menu Functions Short Press (when off) Short Press:(when on) Long Press Extended Long Press Short press in Menu mode Short Press Press and Hold Short press in Menu mode Turns scale on. If balance is on, sets display to zero. Turns scale off. During power up, enters Menu mode. Accept setting on display. Sends print command to COM interface port. If Display Hold or Totalize mode is active, short press enters that mode. Scroll through Units. Release on desired unit. No (toggles through available settings) Locking the Menu The Lock Switch is used to lock out the menu mode, preventing unauthorized changes. To lock the menus, position the Lock Switch next to the tab on the bottom of the balance as shown. Locked Unlocked Scout Pro Balance Quick Start Guide ii Ohaus Corporation
8 Quick Start Guide Scout Pro Balance OPERATION Weighing Start with the balance on. 1 (Rezero the display) (Place sample on platform) (Example 0g) Taring a Container s Weight Taring zeros the container weight. With balance on, place an empty container on the platform. (Container weight) 1 (Container weight tared) (Place material in container) (Material and container removed) (0g sample) To remove tare, press ON/ZERO Off again. ADDITIONAL OPERATIONS Use the Units Menu to activate Parts Counting or Percent Weighing. (See back page.) To enable Display Hold, Totalize and Specific Gravity, use the Setup/Mode submenu. Parts Counting has two modes: (See Instruction Manual for more details.) Normal: balance determines quantity based on average weight of parts in original reference quantity. Enhanced: additional parts can be added to the platform ( the original number). The additional reference quantity produces a more accurate average part weight. Percent Weighing: place a reference weight on the balance, then view other loads as a percentage of the reference. The reference weight equals100%. Display-Hold mode captures and stores the highest stable value. When displayed, the stability indicator blinks. Note: Units cannot be changed when in Display-Hold mode. Totalize allows storage of a series of weight measurements. Totalize mode has been initiated when t and the current unit are displayed together. When totalized weight is shown, the t indicator blinks. Note: Units cannot be changed when in Totalize mode. The Specific Gravity mode allows calculating the specific gravity of a sample. (SPEC.GR mode must be turned ON before removing platform and installing hook.) Ohaus Corporation iii Scout Pro Balance Quick Start Guide
9 Scout Pro Balance Quick Start Guide MENU NAVIGATION There are four main menus in the balance:.c.a.l.,.s.e.t.u.p.,.u.n.i.t.s. and.e.n.d. (Start with the balance off and the Lock Switch off: see page ii). The sequence is shown below. 1 (Acquiring zero value) (Weigh Mode) MENU STRUCTURE Accepting/Bypassing Menu Items Start with menu item displayed = YES Accept = NO (Short presses advance through menu) Cal Yes/No Setup Auto-Off Lin Cal -Yes/No Mode -Hold -Totalize -Specific Gravity Off End -Yes/No Units g kg oz lb PC -Count -Cnt.Enh Off % End -Yes/No End Yes/No * * P/N Scout Pro Balance Quick Start Guide iv Ohaus Corporation
10 Quick Start Guide YA Gold Series PREPARATION FOR USE The YA Gold Series scale comes fully assembled, except for battery installation. Use two high quality AAA batteries: insert in sequence, both in positive direction, as shown: AAA + + Allow at least seconds warm-up time, for scale to stabilize before operation. PROPER ENVIRONMENT For dependable operation of this product, observe the following precautions: Avoid exposure to extreme heat or cold. Allow at least one hour stabilization after temperature change. Keep the scale in a clean environment. Dust, dirt, moisture, vibration, air currents, or proximity to other electronic equipment could adversely affect reliability and accuracy. Avoid shaking, dropping, or shocking the scale. Do not operate this product in unstable environments. Only operate the scale on a stable, vibration-free surface. Gently place items to be weighed on the platform. Rough treatment could damage the internal components. DISPLAY Tare mode (container weighing) Negative sign Symbols for: Grams, Ounces, Carats, Grains, Pieces (not used) Zero mode (standard weigh) Ohaus Corporation i YA Gold Series Pocket Scales Quick Start Guide
11 YA Gold Series Quick Start Guide OPERATION Place the scale on a horizontal flat surface. Press ON/OFF. Wait until 0.00 appears. Press MODE to switch weighing units: g-grams, oz-ounces, ct-carats or gngrains. Put the item to be weighed on the platform (eg,.1 carats). TARE: Turn on the scale as described above. Place a container on the platform (eg,.2 grams). Press TARE. The display shows 0.00 with TARE at left. Add material to the container (eg, 2 grams). Display shows weight of material not the container. When container and material are removed, display will show weight of container as negative value. ADDITIONAL OPERATIONS CHANGING UNITS OF MEASURE: Press Mode to toggle among four choices. Default: Grams g Press Mode once to choose Ounces oz Press Mode again to choose Carats ct Press Mode again to choose Grains gn * * P/N YA Gold Series Pocket Scales Quick Start Guide ii Ohaus Corporation
CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI
American Weigh Scales, Inc. CQ-Series Digital Pocket Scale 7 4 1 0. 8 9 5 6 2 3 x = - CALI + CALC MODE M CAL AC CE % TARE OFF ON MC MR CQ-350 (350x0.1g) CQ-500 (500x0.1g) User Manual CQ-Series Manual Thank
More informationHIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP-2004-12 ver.1.0
HIGH PRECISION BALANCE MWP OWNER S MANUAL MWP-2004-12 ver.1.0 INTRODUCTION------------------------------------------------1 1. INSTALLATION---------------------------------------------------2 Unpacking---------------------------------------------------------------2
More informationXP Series Balances Operation Manual
XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business
More informationOperating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
More informationADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE
PR E C I S I O N ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE Download Rates at WWW.PELOUZE.COM MODEL PS5DL 5 lb. Capacity Small/Large Packages OPERATOR S MANUAL Please take a few minutes to
More informationSERVICE MANUAL Valor 3000 SCALES
SERVICE MANUAL Valor 3000 SCALES Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000 SERVICE MANUAL Valor 3000 SCALES The information contained in this manual is believed
More informationWhen your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.
Voyager Pro Analytical and Precision Balances When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task. Voyager Pro s Advanced Applications simplify even the
More informationBW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
More informationACS-3S/NEW SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL
ACS- SU ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL Thank you for choosing our ACS-3S / NEW SU single/double side display electronic waterproof weighing/counting scale. The new SU
More informationHigh precision counting scale. Operation Manual. l RCZ-A Series
High precision counting scale Operation Manual l RCZ-A Series TABLE OF CONTENTS I. PRECAUTIONS BEFORE USING THE SCALE 1 II. EXPLANATION OF DISPLAY SYMBOLS 2 III. KEYPAD FUNCTIONS 4 IV. OPERATIONS 5 SWITCH
More informationOperation manual Analytical and precision balances
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operation manual Analytical and precision balances
More informationInstruction Manual FL
3. Operation Overview The most common used features (such as displaying force, peak hold, zero and changing of displayed units) can all be done by pressing a single dedicated key identified on the front
More informationSATEX SA 230. - Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND
- Manual SATEX SA 230 PRECISION BALANCE Weegtechniek holland b.v. Patroonsweg 23-27 3892 DA Zeewolde HOLLAND Tel. + 31 36 522 20 30 Fax. + 31 36 522 20 60 Email info@satex.nl Website www.satex.nl page
More informationAdam Equipment. CPWplus. RANGE OF SCALES (P.N. 9009, Rev. C, June 2008)
Adam Equipment CPWplus RANGE OF SCALES (P.N. 9009, Rev. C, June 2008) Adam Equipment Company 2008 Adam Equipment Company 2008 CONTENTS 1.0 INTRODUCTION...3 2.0 SPECIFICATIONS...4 3.0 INSTALLATION...5 3.1
More informationModel 349KLX Remote Display Digital Scale User Instructions
Model 349KLX Remote Display Digital Scale User Instructions P/N UM349KLX Rev 3-080713 1 Model 349KLX Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully,
More informationAppendix C. Vernier Tutorial
C-1. Vernier Tutorial Introduction: In this lab course, you will collect, analyze and interpret data. The purpose of this tutorial is to teach you how to use the Vernier System to collect and transfer
More informationMini Portable Reader (MPR) Model HS 5900L F
Mini Portable Reader (MPR) Model HS 5900L F TABLE OF CONTENTS Chapter 1: Mini Portable Reader (MPR) Basics 1 1.1 Preparing for Operation 1 1.2 Installing/Changing Batteries 1 1.3 Scanning with the Mini
More informationMy Weigh Ultraship Series User Manual
My Weigh Ultraship Series User Manual Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of Ultraship malfunction and inaccuracy! We test all of our scale returns from consumers.
More informationQuick start guide. ML17939/17959 Two-line corded telephone/ answering system with caller ID/call waiting
Quick start guide ML17939/17959 Two-line corded telephone/ answering system with caller ID/call waiting Installation preparation You must install the power adapter before using the telephone. See pages
More information1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
More informationETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
More informationModel 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
More informationPA Series Precision Analytical Balances USER MANUAL
PA Series Precision Analytical Balances USER MANUAL (Software Revision: 2.35) Page 2 of 32 Page 3 of 32 CONTENTS 1.0 INTRODUCTION...4 2.0 TECHNICAL SPECIFICATIONS...5 3.0 UNPACKING THE BALANCE...6 4.0
More informationEvolution Digital HD Set-Top Box Important Safety Instructions
Evolution Digital HD Set-Top Box Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near
More informationCAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN
Evolution Digital HD Set-Top Box Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near
More informationOEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
More informationUser Guide. Temperature and Humidity Datalogger. Model 42280
User Guide Temperature and Humidity Datalogger Model 42280 Introduction Congratulations on your purchase of the Extech 42280 Thermometer and Relative Humidity Datalogger. The 42280 is a wall-mount, tripod
More informationProgramming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
More informationJVC Monitor Calibration 2 User's Guide
JVC Monitor Calibration 2 User's Guide Table of Contents 1. What is JVC Monitor Calibration 2? 2. System Requirement 3. Installation (JVC Monitor Calibration 2) 4. Uninstall 5. Installation (EyeOne Display
More informationMilwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01
Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationCONTIENTS. 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3
CONTIENTS 2008.4 1. SPECIFICATIONS (mm)---------- 2 2. CAUTIONS--------------------- 3 3. INSTALLATION INSTRUCTION----- 3 4. PANEL LAYOUT----------------- 4 5. BUTTON FUNCTIONS------------- 5 6. OPERATING
More informationELECTRONIC COUNTING SCALE. Operation Manual. l JCS- A SERIES
ELECTRONIC COUNTING SCALE Operation Manual l JCS- A SERIES CONTENTS I. Specification:... II. Operation:... III. Weight calibration:... IV. RS232 transmission confer Data format (optional) V. Regular trouble
More informationUser Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
More informationHP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
More informationOperating Instruction METTLER TOLEDO High-Capacity PM-Scales
Operating Instruction METTLER TOLEDO High-Capacity PM-Scales 0.0 g 2 Thank you very much for the confidence you have shown in our products by choosing a METTLER TOLEDO precision scale. To obtain complete
More informationThermistor Thermometer MODEL NO. 93210-00
Thermistor Thermometer MODEL NO. 93210-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail:
More informationRACEAIR REMOTE PAGER SYSTEM
Computech Systems, Inc. 301-884-5712 30071 Business Center Dr. Charlotte Hall, MD 20622 RACEAIR REMOTE PAGER SYSTEM TM Introduction: Computech s RaceAir Remote Competition Weather Station with the Data
More informationVideo Cassette Player
3-862-516-11 (1) Video Cassette Player Operating Instructions Owner s record The model and serial numbers are located at the rear of the unit. Record these numbers in the spaces provided below. Refer to
More informationDehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
More informationUser's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600
User's Guide ExStik DO600 Dissolved Oxygen Meter II RECALL Dissolved Oxygen DO600 Introduction Congratulations on your purchase of the ExStik DO600 dissolved oxygen / temperature meter which simultaneously
More informationSetting Up the Cisco IP Phone
CHAPTER 3 This chapter includes this following topics, which help you install the Cisco IP Phone on an IP telephony network: Before You Begin, page 3-1 Installing the Cisco IP Phone, page 3-6 Adjusting
More informationDMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd. 2012 Dream Swing - 1 -
DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd. 2012 Dream Swing - 1 - DREAM SWING THESE INSTRUCTIONS ARE IMPORTANT. PLEASE READ CAREFULLY AND RETAIN FOR FUTURE REFERENCE. Read the entire instruction before
More informationQUICK START GUIDE Bluetooth Cordless Hand Scanner (CHS)
QUICK START GUIDE Bluetooth Cordless Hand Scanner (CHS) 1D Imager Models CHS 7Ci, 7Di, 7DiRx LED Trigger button Power button (also for ios Keyboard Pop-up) Model shown: CHS 7Di This document pertains to
More informationOwner s Guide. ca6554
PROFESSIONAL SERIES Owner s Guide For Models: ca6554 Deluxe Vehicle Security and Remote Start System with 2 Way Confirming LCD Remote Control IMPORTANT NOTE: The operation of the Security and Convenience
More informationM O D U L E - 7 E Model CS-Caliprompter Operator s Manual
O P E R A T I O N S A N D P R O C E D U R E S F O R C S - C A L I P R O M P T E R A N D A C C E S S O R I E S Model CS-Caliprompter Visual screen display allows easy step-by-step operation On-site programming
More informationConnecting to an AC Power Outlet (Optional) General Description. a Connect the AC adapter to the printer. b Connect the AC power cord to the AC
QUICK SETUP GUIDE PJ-6/PJ-63/ PJ-66/PJ-663 Mobile Printer For more information on using this printer, be sure to read the Pocket Jet User s Guide, which is included on the CD-ROM. Warranty information,
More informationUser Guide for Cisco Unified IP Phones 7961G and 7941G
User Guide for Cisco Unified IP Phones 7961G and 7941G Common Phone Tasks Softkey Definitions View online help on the phone Press. Place a call Redial a number Switch to the handset during a call Switch
More informationInstruction Manual Crane Scales PCE-HS Series
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business
More informationtorbalcloud.com Instruction Manual: DRX-500s CLOUD
torbalcloud.com Instruction Manual: DRX-500s CLOUD Table of Contents Introduction, Setup, and Initial Configuration 1. Cautionary Notes and Precautions. 3 1.1 Important Handling Cautions and Warnings.
More informationLinkRunner Pro TM. Network MultiMeter Quick Reference Guide. Welcome. What s in the box?
Welcome LinkRunner Pro TM Network MultiMeter Quick Reference Guide Thank you for purchasing Fluke Networks LinkRunner Pro! This test tool enables you to quickly check the network, test a cable, or PING.
More informationRI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
More informationUser checks and maintenance of laboratory balances
Technical Note 13 March 2014 Issued: July 1995 Amended and reissued: July 2005, July 2007, October 2007, May 2010, March 2013, March 2014 User checks and maintenance of laboratory balances Copyright National
More informationDigital Photo Frame User s Manual
OM6075US001-CMYK Digital Photo Frame User s Manual Questions? Need Some Help? This manual should help you understand your new product. If you still have questions, call our help line found on the insert
More informationIndoor Remote Controlled Power Points
Indoor Remote Controlled Power Points Model Number: HE214039 INSTRUCTION MANUAL Description goes here Indoor Remote Controlled Power Points Warranty Details The product is guaranteed to be free from defects
More informationUSER GUIDE. Cisco Small Business Pro. SPA 500 Series IP Phones Models 504G, 508G, and 509G. Provided by
USER GUIDE Cisco Small Business Pro SPA 500 Series IP Phones Models 504G, 508G, and 509G Provided by Understanding Your Phoneʼs Lines and Buttons Use the following graphic and table to identify the parts
More informationEUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call 0333 6000 600
EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM Nationwide Low Call 0333 6000 600 WHY BUY WHEN YOU CAN HIRE SlopeView TLL-90 User Guide V20100426 1 CONTENT Title Page 1 Introduction
More informationModel No. KX-TGP500. Model No. KX-TGP550
Panasonic Telephone Systems KX-TGP500/KX-TGP550 KX-TGP500, KXTGP500, TGP500, KX-TGP550, KXTGP550, TGP550 www.voicesonic.com Phone 877-289-2829 User Guide SIP Cordless Phone Model No. KX-TGP500 Model No.
More informationUsing GIGABYTE Notebook for the First Time
Congratulations on your purchase of the GIGABYTE Notebook P7! This Manual will help you to get started with setting up your notebook. For more detailed information, please visit our website at http://www.gigabyte.com.
More informationTesting Your Laboratory Balance
Testing Your Laboratory Balance If you use a laboratory balance in your day-to-day work, you may have wondered whether it is accurate. Here are four tests that you can use to confirm your instrument's
More informationLIFESTYLE V35/V25 HOME ENTERTAINMENT SYSTEMS T20/ T10 HOME THEATER SYSTEMS. Setup Guide Guía de instalación Guide d'installation
LIFESTYLE LIFESTYLE V35/V25 HOME ENTERTAINMENT SYSTEMS T20/ T10 HOME THEATER SYSTEMS Setup Guide Guía de instalación Guide d'installation TAB 8 TAB 7 TAB 6 TAB 5 TAB 4 TAB 3 TAB 2 English SAFETY INFORMATION
More informationUser manual DMX CONTROL 512. Table of contents
User manual DMX CONTROL 512 Table of contents 1. SAFETY INSTRUCTIONS... 4 2. OPERATING DETERMINATIONS... 4 3.OVERVIEW... 6 3.1.REAR PANEL CONNECTIONS... 6 3.2.FRONT PANEL... 6 4.MENU... 6 4.1.CHOOSE FIXTURES...
More informationComputer Lane Monitor for Windows
Computer Lane Monitor for Windows User Guide Supplement BRUNSWICK SERVICE PARTS & SUPPLIES MUSKEGON, MICHIGAN 1995, Brunswick Bowling and Billiards Corporation, 525 W. Laketon Avenue, P.O. Box 329, Muskegon,
More informationMAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
More informationINSTRUCTIONS FOR VOICE CONTROLLED TALKING ALARM CLOCK
INSTRUCTIONS FOR VOICE CONTROLLED TALKING ALARM CLOCK TIM-230-520-2030 User Instructions: Note: When the clock is connected to the provided AC Adapter, the Voice Trigger mode must be active. This will
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationGPSMAP 62 series quick start manual. For use with the GPSMAP 62, 62s, 62st, 62sc, and 62stc
GPSMAP 62 series quick start manual For use with the GPSMAP 62, 62s, 62st, 62sc, and 62stc Getting Started warning See the Important Safety and Product Information guide in the product box for product
More informationTroubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips
Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures
More informationSA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
More informationMilwaukee USER MANUAL
Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the
More informationPrinted in China. Issue 4 AT&T 12/11. Message Guard is a registered trademark of Advanced American Telephones.
www.telephones.att.com 2011 Advanced American Telephones. All Rights Reserved. AT&T and the AT&T logo are trademarks of AT&T Intellectual Property licensed to Advanced American Telephones, San Antonio,
More informationAT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974
974QSG_(Rev14)ml_23.5.06 5/23/06 11:28 AM Page 1 QUICK START GUIDE AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974 This Quick Start Guide provides basic instructions.
More informationHomeSeer Technologies. HomeSeer Technologies LLC 35 Constitution Dr, Suite C Bedford NH, 03110 www.homeseer.com
HomeSeer Technologies HomeSeer Z-Troller Z-Wave Computer Interface Installation guide HomeSeer Technologies LLC 35 Constitution Dr, Suite C Bedford NH, 03110 www.homeseer.com Description Thank for your
More informationSERVICE MANUAL VALOR 7000. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000
SERVICE MANUAL VALOR 7000 Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000 SERVICE MANUAL VALOR 7000 The information contained in this manual is believed to be accurate
More informationConfig software for D2 systems USER S MANUAL
DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------
More informationParts List. Navigation
Parts List quantity description 1 LCD-200 Display 1 LCD-200 Display cable 1 CD-ROM 2 dual lock or velcro 1 1GB SD card (optional) 1 CAN termination plug Navigation Main Menu Begin Log/Stop Log page 4 Log
More informationExpress5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
More informationSwitchView 1000 Switch. Installer/User Guide
SwitchView 1000 Switch Installer/User Guide SwitchView 1000 Switch Installer/User Guide Avocent, the Avocent logo, The Power of Being There and SwitchView are registered trademarks of Avocent Corporation.
More informationModel No. KX-TGP500. Model No. KX-TGP550
User Guide SIP Cordless Phone Model No. KX-TGP500 Model No. KX-TGP550 Model shown is KX-TGP500. Model shown is KX-TGP550. Thank you for purchasing a Panasonic product. You can configure some of the features
More informationInstallation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types
Installation Guide LR-HWLV-HVAC TouchPRO Wireless Touchscreen Thermostat System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, high efficiency furnaces, heat pumps, steam,
More informationPA500II Enterprise Mobile Computer
PA500II Enterprise Mobile Computer - PA500II - Quick Reference Guide 400891G Version 1.0 PA500II Product Introduction & Accessory Kit After opening the box, ensure the following accessories for the PA500II
More informationBLOOD COLLECTION MIXER
USER S MANUAL BLOOD COLLECTION MIXER Model CM735 No. CAT.CM73522Ce Centron Technologies Corporation 319-25 Sadang-4-dong, Dongjak-ku Seoul, Korea 156-823 Tel. +82-2.522.7807 Fax +82-2.522.7806 Table of
More informationModel SPA 303G Quick Start Guide
mydatavo Model SPA 303G Quick Start Guide Welcome Thank you for choosing Datavo as your business solutions provider. This guide describes how to install your phone and how to perform some basic tasks.
More informationUser's Guide. Pinless Moisture Meter. Model MO257
User's Guide Pinless Moisture Meter Model MO257 Introduction Congratulations on your purchase of the Extech MO257 Pinless Moisture Meter. The pinless moisture sensor monitors the moisture in wood and other
More information4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
More informationUser Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More informationCL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
More informationOperating Instructions
PLEASE READ BEFORE USE AND SAVE. Integrated Telephone System Model No. KX-T7FXW Pulse-or-tone dialing capability Operating Instructions Preparation Basic Operation Advanced Operation Useful Information
More informationsnom 370 Quick Installation Kurzanleitung VoIP Business Phone www.snom.com 2007 snom technology AG All rights reserved. Version 1.
snom 370 VoIP Business Phone Quick Installation Kurzanleitung 2007 snom technology AG All rights reserved. Version 1.0 www.snom.com snom technology AG Gradestr. 46 D-12347 Berlin, Germany Note to the reader
More informationANALYTICAL BALANCE OPERATION MANUAL. (FA/JA Series)
ANALYTICAL BALANCE OPERATION MANUAL (FA/JA Series) CONTENT I. II. III. IV. V. VI. VII. Brief Introduction...1 Main Technical Specifications...1 Drawings for Balance Installation...2 Operation...3 Maintenance
More informationUse and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
More informationOCS-S High Resolution Digital Crane Scale
OCS-S High Resolution Digital Crane Scale Content 1. Safety Guide... 1 2. Features... 1 3. Specifications... 2 4. Capacity... 2 5. Dimension & Weight... 3 6. Display & Keys... 4 Scale Keys... 4 Indicators...
More informationMonitoring Network DMN
Monitoring Network DMN User Manual Table of contents Table of contents... 2 1. Product features and capabilities... 3 2. System requirements... 5 3. Getting started with the software... 5 3-1 Installation...
More informationSetting Up the ZigBee Ethernet Gateway
Setting Up the ZigBee Ethernet Gateway MAN-01-00030-1.4 This manual describes how to install and set up ZigBee communication between a SolarEdge device (Inverters or Safety and Monitoring Interface) and
More informationDAB Radio. Instruction Manual L55DAB10
DAB Radio Instruction Manual L55DAB10 L55DAB10_IB_110810_Zell.indd 1 L55DAB10_IB_110810_Zell.indd 2 Contents Unpacking...5 Product Overview...6 Top View... 6 Rear View... 6 Power Source...7 Battery Power...
More informationQuick Guide. Precision Balances XS models
Quick Guide XS models Table of Contents Introduction 5 Safety Information 6. Definition of signal warnings and symbols 6. Product safety information 6 3 Design and Function 8 3. Overview 8 3.. S weighing
More informationE E V R E - R S - O S L O A L R
Solar Eye User Manual Edition JIANGSU EVER-SOLAR NEW ENERGY CO., LTD. Revision History Date Edition Specification 17/08/2011 1.0 Create File 02/09/2011 1.1 Add Micro SD function description www.ever-solar.com
More informationHow To Use A Ci 2001A/B (I2) With A Power Supply (I3)
Weighing Indicator CI-2001A/B OWNER S MANUAL CONTENTS PRECAUTIONS 4 INTRODUCTION 6 THE FEATURES OF CI-2001A/B 6 TECHNICAL SPECIFICATION 7 DIMENSIONS 8 FRONT PANEL(CI-2001A) 9 FRONT PANEL(CI-2001B) 11 REAR
More informationBUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.
Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER
More informationINDUSTRIAL INSTRUMENTATION
INDUSTRIAL INSTRUMENTATION Table of contents. Table of contents.... 2 Explanation of production screen.... 3 Wiring connection for Flex-MF model Flex.... 4 Wiring connection for Flex-MF model Flex-2100....
More information