Metrics for Data Centre Efficiency

Similar documents
scalable data centre energy management solution

Portable Energy Efficient Data Centre Solution

THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers

AbSTRACT INTRODUCTION background

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCIE

Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design

Engineering & Support Services

Case Study Nottingham Trent University

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

Smarter Data Centers. Integrated Data Center Service Management

Metering and Managing University of Sheffield Data Centres. Chris Cartledge Independent Consultant

Guidance for Calculation of Efficiency (PUE) in Data Centers

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

ICT and the Green Data Centre

Data centre energy efficiency metrics. Existing and proposed metrics to provide effective understanding and reporting of data centre energy

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Guidance for Calculation of Efficiency (PUE) in Data Centers

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Datacenter Efficiency

Server Room, Data Centre Management and Monitoring Solutions

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Drives and motors. A guide to using variable-speed drives and motors in data centres

Energy Management Services

Definition of effective metrics for evaluating the efficiency of hybrid power systems at telecom cell sites

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

DATA CENTRE DESIGN AND

Office of the Government Chief Information Officer. Green Data Centre Practices

Energy Savings in the Data Center Starts with Power Monitoring

Improve competiveness of IDC and enterprise data centers with DCIM

Optimization of energy consumption in HPC centers: Energy Efficiency Project of Castile and Leon Supercomputing Center - FCSCL

Leveraging Renewable Energy in Data Centers: Present and Future

Colocation Selection Guide. Workspace Technology Ltd

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Best Practice Guide BPGCS007

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Calculating Total Power Requirements for Data Centers

Data Centers: Definitions, Concepts and Concerns

InfraStruxure Data Centre Management Software. Holistic open standards integrated data centre management solution.

Data Center Combined Heat and Power Benefits and Implementation. Justin Grau, Google Inc. Sam Brewer, GEM Energy

Measuring Power in your Data Center

Energy management White paper. Greening the data center with IBM Tivoli software: an integrated approach to managing energy.

Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators

WATER USAGE EFFECTIVENESS (WUE ): A GREEN GRID DATA CENTER SUSTAINABILITY METRIC

Green Data Centre Design

Capgemini UK Infrastructure Outsourcing

Benchmarking results from Indian data centers

Data Center Power Distribution and Capacity Planning:

Mixing Sodium and Lead Battery Technologies in Telecom Applications

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Data Center Facility Basics

EU Code of Conduct for Data Centre Efficiency

Foreseer Services. Product application guide. Table of contents

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

Global Green Data Center Best Practices In Action

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Data Centre Solutions energy efficient by design

Data Center Energy Use, Metrics and Rating Systems

Greener Pastures for Your Data Center

Electrical Efficiency Measurement for Data Centers

Agenda. Part I: Introduction to OptimumHVAC. Part II: Initial Energy Savings Analysis for MCO Main Terminal. Part III: Case Studies & Conclusion

THE GREEN DATA CENTER

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

DataCenter 2020: first results for energy-optimization at existing data centers

How To Improve Energy Efficiency In A Data Center

Case Study University of Aberdeen

Data Centre Testing and Commissioning

Direct Fresh Air Free Cooling of Data Centres

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Living Green in the Data Center. Dominick Regina Associate Director, Infrastructure Services

Energy Tutorial: Energy Usage. Reading meters and understanding fuel bills

Electrical Efficiency Modeling for Data Centers

SoSe 2014 Dozenten: Prof. Dr. Thomas Ludwig, Dr. Manuel Dolz Vorgetragen von Hakob Aridzanjan

Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning

Green ICT: Consistent Actions to Reduce Energy Consumption

Green HPC - Dynamic Power Management in HPC

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

The necessary convergence of IT and Facilities

ENERGY MANAGEMENT SOFTWARE. For Windows XP, Vista, Windows 7 ( 32 & 64 bit ) Mac OSX 10.5+

Transcription:

Technology Paper 004 Metrics for Data Centre Efficiency Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile: 0121 354 6447 email: sales@workspace-technology.com Published in January 2008

Introduction Energy efficiency is imperative to environmental and IT economic productivity and can no longer be ignored. Slowing the growth rate of electric power use for servers and data centres is necessary to reduce the rate of growth of greenhouse gas emissions. The current level of consumption makes IT hardware and data centres a leading contributor to carbon emissions. Technology Paper 002 Server Room & Data Centre Energy Efficiency provides further details on this subject. Metering the total energy used at a site is important, but it does not show how energy consumption is being used across an area, or for specific applications such as a data centre. Therefore, it can be hard to understand why and where energy performance is poor and how to improve it. The Carbon Trust recommends the implementation of the sub metering of key energy consumption elements. This Technology Paper provides a high level overview of the measurement strategy which has been formulated by The Green Grid, an association of I.T professionals seeking to dramatically raise the energy efficiency of data centres. Server Room Efficiency Measurement & Metrics As part of any energy reduction strategy it is imperative to recognise the importance of establishing metrics to specifically measure data centre efficiency. Metrics can show how systems are currently performing and help drive the tune up process. There are two related metrics that have been recently introduced to the industry, Power Usage Effectiveness (PUE) and Data Centre Efficiency (DCE). The PUE is defined as follows: Power Usage Effectiveness (PUE) = Total Facility Power and its reciprocal, the DCE is defined as: Data Centre Efficiency (DCE) = I.T Equipment Power I.T Equipment Power Total Facility Power 1. I.T Equipment Power. This includes the load associated with all of the I.T equipment, such as compute, storage, and network equipment, along with supplemental equipment such as KVM switches, monitors, and workstations/laptops used to monitor or control the Data Centre. 2. Total Facility Power. This includes everything that supports the I.T equipment load such as:- Total I.T Equipment Power Power delivery components such as UPS, switch gear, generators, PDU's batteries, and distribution losses external to I.T equipment. Cooling systems components such as chillers, computer room air conditioning units, direct expansion air handler (DX) units, pumps, and cooling towers. Other misc. loads including lighting, BMS panels etc. 2

The use of PUE and DCE The use of the PUE and DCE provides a way to determine :- Opportunities to improve a Server Room or Data Centres operational efficiency How a Server Room or Data Centre compares to other competitive facilities A method of ongoing monitoring of the Server Room or Data Centre efficiency. The best position to measure the Total Facility Power is at the input power feeds to the server room. This should represent the total power entering the data centre (for which the utility supplier will charge). Typically the practical measurement point for I.T Equipment Power is the output of the UPS or UPS bypass switch, which in turn feeds critical distribution power boards and hence the critical I.T equipment load. In an ideal Server Room, 100% of the electricity draw is delivered to the servers, i.e. there are no overheads required for distribution or cooling. This would lead to a PUE / DCE = 1. With current technology, it is not possible to achieve this scenario. A typical example of an old style data centre, is one with the total facility power at 40Kw and the critical load at 10Kw, resulting in a PUE of 4.0. Preliminary work indicates that many Data Centres may have a PUE of 3.0 or greater. Workspace Technology's goal is to ensure that all of its solutions are 2.0 or less, with the goal of achieving ratios of 1.5, by using the latest energy efficiency technology and through design. 3

Overall energy consumption > The relationship between power and energy The DCE and PUE figures are relative and prove the overall effectiveness of the server room infrastructure design and efficiency. They do not in themselves measure the actual total energy consumption. Difference between Power and Energy In a Data Centre, peak power demand determines how big the UPS, Cooling systems and utility power feeds need to be. Reducing the peak power demands through server virtualisation tends to reduce the Capex Investment for new data centres and allows for deferment of expensive capacity expansions to existing data centres. Enterprise sustainability initiatives are typically more interested in energy because energy consumption determines the quantity of fuel which must be burned at a power plant, with its requisite emissions of carbon dioxide. Power - spot measurement at a point in time Energy - is consumed over a period of time. The distinctions are important because it is possible for systems to draw a lot of power without using much energy and vice versa. For example a 1500W hairdryer used 5 minutes each day uses 15x more instantaneous power than a 100W light bulb left on all year but the hair dry only uses about 1/20 as much energy. If a Data Centre really draws the same amount of power every hour of the year, then the energy use in Kwh is just the same as power in Kw x 8,760 hours. However, in a green data centre, annual energy use will not be the peak power times 8,760 hours, because:- Idle servers and storage can be set to hibernate at off peak times, at night, or on weekends. Free cooling can be used during some hours of the day and year depending on external ambient temperature. Future generations of I.T equipment might be designed to draw less than their peak power when they are only running at partial computer load. Power is measured in Kilowatts (Kw) while energy is measured in Kilowatt hours (Kwh). 4

Conclusions Conclusion You cannot manage what you do not know, therefore the measurement of energy efficiency is crucial to ensure that the any data centre or server room delivers effective power distribution and cooling. The use of the Power Usage Effectiveness (PUE) and Data Centre Efficiency (DCE) ratios are simple tools which clearly demonstrate the efficiency of any size, shape or form of server room facility. In time, it is anticipated the server room infrastructure can be graded in a similar fashion to energy labels used on consumer products. For a complete picture of server room and data centre efficiency, the comparative energy figures must also be identified. The implementation of any future server virtualisation and server room infrastructure fine tuning and technology investments must be clearly measurable. The implementation of products such as Workspace Technology's EcoMeasure are an excellent way for data centre managers to accurately track and benchmark improvements as changes, additional equipment and technology are deployed. About Workspace Technology Workspace Technology provides a range of services for Network Critical Physical Infrastructure (NCPI) facilities which include communications, server and data centre facilities. The design and implementation of * energy efficient solutions forms part of Workspace Technology s overall strategy for providing clients with a complete turnkey approach to the design and build of server room and data centre solutions. Workspace Technology s expertise and services incorporates consultancy, upgrades, expansion, re-locations, turnkey design & build, planned maintenance and support and remote monitoring services. A copy of Workspace Technology s Environment Server Room Solutions and Services can be downloaded from. Workspace Technology are approved Integration Partners for a number of leading manufacturers for UPS and critical cooling systems and are APC InfrastruXure Partners. * represents Workspace Technology s commitment to help clients reduce their carbon footprint through the deployment of energy efficient technology and designs Workspace Technology Limited Technology House, 5 Emmanuel Court, Reddicroft, Sutton Coldfield West Midlands B72 1TJ Telephone: 0121 354 4894 Facsimile: 0121 354 6447 email: sales@workspace-technology.com Silver Solutions Partner Systems Integrator 5 C r e a t i n g a n e f f e c t i v e w o r k s p a c e e n v i r o n m e n t