Rosemount 708 Wireless Acoustic Transmitter



Similar documents
Rosemount 248 Wireless Temperature Transmitter

Emerson Smart Wireless Gateway Solutions

Emerson Smart Wireless Gateway

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 333 HART Tri-Loop

Rosemount 1199 Submersible Seal

Microcor Wireless Transmitter (MWT)

Rosemount 333 HART Tri-Loop

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

Rosemount 1199 Submersible Seal

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Rosemount 751 Field Signal Indicator

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications

Rosemount 702 Wireless Discrete Transmitter

Rosemount D Solids Scanners for Bulk Solids Inventory and Financial Reporting

Quick Start Guide , Rev DA June Emerson Smart Wireless Gateway 1410

Wireless Field Data Backhaul

EMERSON S ROSEMOUNT PROJECT MANAGEMENT OFFICE. Delivering project success for your instrumentation

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas

Wireless Sensor Networks

Smart Wireless Solutions. Intelligent Well Production Starts Here

Cisco Aironet 1520 Series Lightweight Outdoor Access Points

LEVEL AND VOLUME MEASUREMENTS OF BULK SOLIDS

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Lockout Specification BW Clip Maintenance-free single gas detector

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices

Micro Motion 3098 Gas Specific Gravity Meter

1.1 Fill fluids. Rosemount DP Level Fill Fluid Specifications July Technical Note , Rev DB

S-series Mass Connection Solutions

S-series SQ Controller

Emerson s Smart Wireless and WIB Requirements

Rosemount 248 Temperature Transmitter

Replacing Displacers with Guided Wave Radar

Fisher 4320 Wireless Position Monitor, with On/Off Control Option

3DLevelScanner II TECHNICAL DATA SHEET

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

DeltaV SISnet Repeater

Model 3051 Pressure Transmitter with HART Protocol

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

CSI 9420 Wireless Vibration Transmitter

Sensor to Systems Connectivity Flexible, Reliable, Ultra Low-Power

Plug and Socket Devices SolConeX 16 A Series 8570

How To Use The Cisco Aironet 1240G Series For A Wireless Network (Wired) And For A Wired Network (Wireless)

S-series DeviceNet Interface Card

No Wires No Limits With Smart Wireless Technology. V.Suresh Senior Sales Manager Emerson Process Management

Compact pressure switch Flameproof enclosure Ex d Model PCA

SEISMIC VELOCITY TRANSDUCER T1-40

Terminal Boxes Series 8146

Monitoring Water Quality For Today s Demanding World

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Cosasco Wireless System

Measurement Products. FieldKey Wireless Adapter Unlock the process and maintenance information stranded in your field instruments

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Import the Gateway Certificate to the Browser

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

WIRELESS INSTRUMENTATION TECHNOLOGY

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

OptiView XG Network Analysis Tablet - Wireless Version The tablet for WiFi network engineers and integrators

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Technical Information RIA14

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Wireless Mobile Workforce

Technical Data. Dimensions

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

Technical Data. Dimensions

TEIP11 I/P signal converter for standard signals. Measurement made easy

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Inductive sensor NI10-M18-Y1X-H1141

Gas flow measuring devices Ultrasonic gas flow meter, FLOWSIC600

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Foxboro Evo Process Automation System

Monitores Equipos Móviles Especificaciones de Producto

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

Technical Data Sheet. 3DLevelScanner

Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Plug and Socket Devices CES 63 A Series 8579

3500/93 System Display

SEE MORE. DO MORE. Bob Karschnia VP Wireless

Flameproof Audible Signal 115 db (A) Series YA90

Mobrey Hydrastep and Hydratect

Wireless Remote Video Monitoring

THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

HP ProCurve Wireless Access Point 10ag Overview

1756 ControlLogix Chassis Specifications

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

S-series DC to DC Power Supply

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Unidirectional Transmitter/ Receiver Units Introduction

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Transcription:

Product Data Sheet January 2015 00813-0100-4708, Rev BB Rosemount 708 Wireless Acoustic Transmitter Improve energy efficiency and environmental compliance with acoustic monitoring of steam traps and pressure relief valves Gain instant visibility to all of your critical steam traps and PRVs through a non-intrusive, WirelessHART monitoring system Know you are backed by Emerson s proven experience in Smart Wireless field instrumentation and expert technical support

Rosemount 708 January 2015 Emerson s Smart Wireless Solution IEC 62591 (WirelessHART)... The industry standard Self-organizing, adaptive mesh routing No wireless expertise required; network automatically finds the best communication paths The self-organizing, self-healing network manages multiple communication paths for any given device. If an obstruction is introduced into the network, data will continue to flow because the device already has other established paths. The network will then lay in more communication paths as needed for that device. Reliable wireless architecture Standard IEEE 802.15.4 radios 2.4 GHz ISM band sliced into 15 radio-channels Time Synchronized Channel Hopping to avoid interference from other radios, WiFi, and EMC sources and increase reliability Direct sequence spread spectrum (DSSS) technology delivers high reliability in challenging radio environment Emerson s Smart Wireless Seamless integration to all existing host systems Native integration into DeltaV and Ovation is transparent and seamless Gateways interface with existing host systems using industry standard protocols including OPC, Modbus TCP/IP, and Modbus RTU Layered security keeps your network safe Ensures data transmissions are received only by the Smart Wireless Gateway Network devices implement industry standard Encryption, Authentication, Verification, Anti-Jamming, and Key Management Third party security verification including Achilles and FIPS197 SmartPower Solutions Emerson SmartPower Solutions provide an intrinsically safe Power Module, allowing field replacements without removing the transmitter from the process, keeping personnel safe, and reducing maintenance costs. 2

January 2015 Rosemount 708 Rosemount 708 Wireless Acoustic Transmitter Ultrasonic acoustic event detection Reliably detects and transmits information about acoustic events such as leaks Transmitter output includes acoustic level (0 to 255 counts) and temperature (-40 to 550 C) Transmitter communicates process variable and status information via the wireless network for integration into existing host systems Monitor steam traps SteamLogic software provides critical, real-time information on the condition of your monitored steam trap population SteamLogic delivers immediate notification of a failed steam trap and its location Real-time monitoring provides instantaneous feedback for system maintenance and optimization Monitor pressure relief valves or pressure safety valves Turbulence generated by a leaky valve can be detected using the acoustic transmitter Notification when release is occurring and when the release has stopped Emerson Smart Wireless network provides time stamped information to the host Automated data enables reporting of a tamper-proof data log Mounting flexibility The wireless acoustic transmitter can be directly mounted to process piping without cutting pipes or changing pipe configurations allowing for a flexible, easy installation. Reliable transmitter performance The rugged and robust design of the transmitter ensures reliable performance in harsh environments. Contents Emerson s Smart Wireless Solution..................... 2 Rosemount 708 Wireless Acoustic Transmitter............ 3 Spare Parts and Accessories.......................... 5 Specifications...................................... 6 Product Certifications............................... 8 Dimensional Drawings.............................. 10 3

Rosemount 708 January 2015 Ordering Information Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 6 for more information on Material Selection. Table 1. Rosemount 708 Acoustic Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product description 708 Acoustic Transmitter Output protocol X Wireless Measurement 1 Steam Traps with SteamLogic software 2 Other Measurements Housing P Engineered Polymer Waveguide configuration A1 Acoustic Waveguide Product certifications NA No Hazardous Location Approval I1 ATEX Intrinsic Safety I2 INMETRO Intrinsic Safety I3 China Intrinsic Safety I4 TIIS Intrinsic Safety I5 FM Intrinsically Safe I6 CSA Intrinsically Safe I7 IECEx Intrinsic Safety Mounting hardware NA00 No Mounting Hardware HC01 Stainless Steel Mounting Band, Pipe size 1 /2 to 2 1 /2-in. HC02 Stainless Steel Mounting Band, Pipe size 3-in. to 4-in. HC03 Stainless Steel Mounting Band, Pipe size 4-in. to 10-in. HT01 High Temperature Stainless Steel Mounting Hardware, Pipe size 1 /2 to 2 1 /2-in. (260 C to 550 C) 4

January 2015 Rosemount 708 Table 1. Rosemount 708 Acoustic Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Wireless options (include with selected model number) Extended product warranty WR3 3-year limited warranty WR5 5-year limited warranty Wireless update rate, operating frequency and protocol WA3 User Configurable Update Rate, 2.4 GHz DSSS, IEC 62591 (WirelessHART) Omni-directional wireless antenna and SmartPower solutions WP5 (1) Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) Configuration C1 Factory Configure Date, Descriptor, Message Fields and Wireless Parameters Typical model number: 708 X 1 P A1 NA HC01 WA3 WP5 (1) Power module must be shipped separately, order 701PGNKF. Spare Parts and Accessories Table 2. Spare Parts and Accessories 00708-9010-0001 High temperature mounting hardware 5

Rosemount 708 January 2015 Specifications Functional specifications Output IEC 62591 (WirelessHART) 2.4 GHz DSSS Humidity limits 0 100% relative humidity Transmit rate User selectable 1 second to 60 minutes Radio frequency power output from antenna Internal (WP option) antenna: Maximum of 10 mw (10 dbm) EIRP Physical specifications Material selection Emerson provides a variety of Rosemount products with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product materials, options, and components for the particular application. Emerson Process Management is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product options, configuration, or materials of construction selected. Electrical connections/power module Replaceable, non-rechargeable, Intrinsically Safe Lithium-Thionyl Chloride power module pack with PBT/PC enclosure Ten-year power module life at reference conditions (1) Field Communicator connections Materials of construction Housing PBT/PC Cover O-ring Silicone Power module housing PBT/PC Wave guide Machined 316L SST Mounting Transmitters are directly attached to process piping using two stainless steel mounting bands. High temperature mounting hardware should be used when process temperatures exceed 260 C (500 F). Weight 708 with power module -1.31 lbs. (0.595 kg) 708 without power module - 0.98 lbs. (0.445 kg) Enclosure ratings NEMA 4X and IP66/67 Performance specifications Vibration effect Tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz 0.21 mm displacement peak amplitude/60-2000 Hz 3g). Temperature limits Ambient Limit -40 C to 85 C (-40 F to 185 F) Storage Limit -40 C to 85 C (-40 F to 185 F) Heat from the process is transferred to the transmitter housing. If the process temperature is high, the ambient temperature will need to be lower to account for heat transferred to the transmitter housing. Communication Terminals - Clips permanently fixed to power module (1) Reference conditions are 70 F (21 C), transmit rate of once per minute, and routing data for three additional network devices. 6

January 2015 Rosemount 708 Table 3. Temperature Derating Process temperature ( C) Max ambient ( C) 260 41 240 45 220 49 200 53 180 57 160 61 140 64 120 68 100 72 85 75 Table 4. High Temperature Process temperature ( C) Max ambient ( C) 550 41 520 45 490 47 460 49 430 51 400 53 370 56 340 58 310 60 280 62 260 63 Electromagnetic Compatibility (EMC) All models Meets all relevant requirements of EN 61326-2-3:2006 Wireless output specifications Acoustic output 0 to 255 counts Temperature output -40 to 260 C (-40 to 500 F) 7

Rosemount 708 January 2015 Product Certifications European Union Directive Information A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EC Declaration of Conformity can be found at. Telecommunication Compliance All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage. FCC and IC This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Ordinary Location Certification for FM Approvals As standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by FM Approvals, a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Installing in North America The US National Electrical Code (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective codes. USA I5 FM Intrinsic Safety (IS) and Nonincendive (NI) Certificate: 3043245 Standards: FM Class 3600 1998, FM Class 3610 2010, FM Class 3810 2005, NEMA 250 2003, ANSI/IEC 60529 Markings: IS CL I, DIV 1, GP A, B, C, D T4; CL 1, Zone 0 AEx ia IIC T4; T4(-40 C T a +70 C) when installed per Rosemount drawing 00708-1000; Type 4X Special Conditions for Safe Use (X): 1. The 708 Wireless acoustic Transmitter shall only be used with the 701PGNKF Rosemount SmartPower Battery Pack. 2. Potential Electrostatic charging Hazard See Instructions. Canada I6 CSA Intrinsically Safe Certificate: 2439890 Standards: CAN/CSA C22.2 No. 0-M91, CAN/CSA C22.2 No. 94-M91, CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No. 157-92, CSA Std C22.2 No. 60529:05 Markings: I.S. CL I, DIV 1, GP A, B, C, D when installed per Rosemount drawing 00708-1001; T3C; Type 4X Europe I1 ATEX Intrinsic Safety Certificate: Baseefa11ATEX0174X Standards: EN 60079-0: 2012, EN 60079-11: 2012 Markings: Ex II 1 G Ex ia IIC T4 Ga, T4 (-40 C T a +70 C) Special Conditions for Safe Use (X): 1. The plastic enclosure of the Model 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth. 2. The Model 701PGNKF Power Module may be replaced in a hazardous area. The power module has a surface resistivity greater than 1GΩ and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up. 8

January 2015 Rosemount 708 International I7 IECEx Intrinsic Safety Certificate: IECEx BAS 11.0091X Standards: IEC 60079-0: 2011, IEC 60079-11: 2011 Markings: Ex ia IIC T4 Ga, T4(-40 C T a +70 C) Special Condition for Safe Use (X): 1. The plastic enclosure of the Model 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth. Brazil I2 INMETRO Intrinsic Safety Certificate: NCC 12.0817X Standards: GB3836.1-2010, GB3836.4-2010, GB3836.20-2010 Markings: Ex ia IIC T4 Ga, T4(-40 C T a +70 C) Special Condition for Safe Use (X): See certificate for special conditions. China I3 China Intrinsic Safety Certificate: GYJ13.1445X Standards: GB3836.1-2010, GB3836.4-2010, GB3836.20-2010 Markings: Ex ia IIC Ga T4,-40 ~+70 C Special Condition for Safe Use (X): See certificate for special conditions. Japan I4 TIIS Intrinsically Safe Certificate: TC20395 Markings: Ex ia IIC T4 (-20 ~ +60 C) Technical Regulation Customs Union (EAC) IM EAC Intrinsic Safety Certificate: RU C-US.Gb05.B.00643 Markings: Ex ia IIC T4 Ga X, T4 (-40 C T a +70 C) Special Condition for Safe Use (X): See certificate for special conditions. 9

Rosemount 708 January 2015 Dimensional Drawings Figure 1. Rosemount 708 Direct Mount Dimensions are in inches (millimeters). Figure 2. Rosemount 708 Acoustic Transmitter with High Temperature Standoff and Fastener Kit A B A. For Pipe Sizes 0.5-in to 2.5-in. B. Bracket Mounting Dimensions are in inches (millimeters). 10

January 2015 Rosemount 708 11

Rosemount 708 00813-0100-4708, Rev BB Product Data Sheet January 2015 Rosemount World Headquarters Emerson Process Management 6021 Innovation Blvd Shakopee, MN 55379, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@EmersonProcess.com North America Regional Office Emerson Process Management 8200 Market Blvd. Chanhassen, MN 55317, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.com Latin America Regional Office Emerson Process Management 1300 Concord Terrace, Suite 400 Sunrise, Florida, 33323, USA +1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@EmersonProcess.com Europe Regional Office Emerson Process Management Europe GmbH Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland +41 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@EmersonProcess.com Asia Pacific Regional Office Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 +65 6777 8211 +65 6777 0947 Enquiries@AP.EmersonProcess.com Middle East and Africa Regional Office Emerson Process Management Emerson FZE P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates +971 4 8118100 +971 4 8865465 RFQ.RMTMEA@Emerson.com Standard Terms and Conditions of Sale can be found at: \terms_of_sale. The Emerson logo is a trademark and service mark of Emerson Electric Co. DeltaV, SmartPower, SteamLogic, Rosemount, and the Rosemount logotype are registered trademarks of Rosemount Inc. WirelessHART is a registered trademark of the HART Communication Foundation. Modbus is a registered trademark of Modicon, Inc. All other marks are the property of their respective owners. 2015 Rosemount Inc. All rights reserved.