Rosemount 1199 Submersible Seal
|
|
|
- Jocelin Cross
- 9 years ago
- Views:
Transcription
1 Product Data Sheet January , Rev BB The Rosemount Submersible Seal design uses innovative DP Level technology to measure level for top-down applications. For this design, the seal and capillary are submersed in the process and installation is made through a connection at the top of the tank. This differs from traditional DP Level installations which are side mounted to tanks via threaded or flanged connections, with only the diaphragm seal in contact with the process. The unique design of the Submersible Seal allows installation through small tank connections while at the same time providing excellent performance and sensitivity characteristics.
2 January 2015 Proven, reliable, and innovative remote seal technology for top down measurement Unlike traditional DP Level systems that use flat diaphragm seals to measure process pressure, the Submersible Seal consists of a compressed bellows design. This design allows the seal to fit through small tank connections, a 1 1 /2 NPT threaded connection or a 2 to 3-in. flanged connection (DN 50 to DN 100), and be submersed into the fluid to provide a top-down level measurement. In addition, this seal design provides significantly better performance compared to a similar sized traditional DP Level diaphragm seal. The can be combined with any Rosemount In-Line Gage Transmitter including all output protocols and hazardous location approvals. Based on reliable and easy to use pressure based level technology Ideal for smaller top-down tank connections, from 1 1 /2 NPT threaded connections to 2-3 inch flanged connections (DN 50 to DN 100) Intended for vented or open tank applications ssemble to any Rosemount In-Line Gage Transmitter Rosemount 3051S_T 4-20 m HRT, WirelessHRT, FOUNDTION fieldbus, PROFIBUS Rosemount 3051T 4-20 m HRT, WirelessHRT, FOUNDTION fieldbus, PROFIBUS Rosemount m HRT, WirelessHRT, FOUNDTION fieldbus, PROFIBUS Rosemount 2088 Submersible Seal System with Wireless Rosemount 3051T 4-20 m HRT Contents Ordering Information Specifications Dimensional Drawings Rosemount 2088 with Submersible Seal Threaded Connection 12 2
3 January 2015 Ordering Information The can be ordered with any Rosemount In-Line Transmitter with the 1199 attach to option. Please refer to the desired Rosemount transmitter PDS for the desired configuration. Ordering codes Transmitter model 3051S_TG 3051TG, 2051TG, 2088G 1 Seal B11 S1 Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 6 for more information on Material Selection. Table 1. The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product description 1199 Seal Systems Connection type Seal system Seal location ll In-Line Transmitters (3051S_TG, 3051TG, 2051TG, 2088G) W ll Welded One Seal System High Side of Transmitter Seal fill fluid Specific gravity at 77 F (25 C) Temperature limits (1) D Silicone to 401 F (-45 to 205 C) G Glycerin and Water to 203 F (-15 to 95 C) Seal connection type/capillary ID, description B 0.03-in. (0.711 mm) ID C 0.04-in. (1.092 mm) ID E 0.03-in. (0.711 mm) ID, PVC Coated with Closed End F 0.04-in. (1.092 mm) ID, PVC Coated with Closed End Measurement length (2) ft (0.5 m) ft (0.7 m) ft (1.2 m) ft (1.7 m) ft (2.2 m) ft (2.7 m) ft (3.2 m) ft (3.7 m) ft (4.2 m) ft (4.7 m) ft (5.2 m) ft (6.2 m) 3
4 January 2015 Table 1. The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product description ft (6.3 m) ft (7.2 m) ft (7.8 m) ft (8.2 m) ft (9.2 m) ft (9.3 m) Industry standard SME B16.5/NSI B (merican National Standards Institute/merican Society of Mechanical Engineers) D EN (European Standard) J JIS B2238 Process connection style TSM Threaded Submersible Seal FSM Flanged Submersible Seal Process connection size Threaded (TSM) NSI B ISO 7-1, DIN 2999, BS 21 (BS EN ), JIS B / NPT N/ Flanged (FSM) JIS B2238 SME B16.5/HG20615 EN / GOST /HG /2 in. N/ G 50 2 in. DN in. N/ J N/ N/ DN N/ DN 100 F N/ N/ DN 40 Pressure rating Threaded (TSM) NSI B ISO 7-1, DIN 2999, BS 21 (BS EN ), JIS B psi 4.13 bar Flanged (FSM) JIS B2238 SME B16.5/HG20615 EN / GOST /HG K Class 150 N/ 2 20K Class 300 N/ 4 40K Class 600 N/ G N/ N/ PN 40 E N/ N/ PN 10 / 16 4
5 January 2015 Table 1. The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Model Product description Diaphragm, upper housing, flange material Diaphragm Upper housing Flange DG SST 316 SST 316 SST Other options (include with selected model number) Process screen 0 No Filter 1 1 /4 in. NPT Screen Insert Extended product warranty WR3 3-year limited warranty WR5 5-year limited warranty (1) t ambient pressure of 14.7 psia (1 bar-a) and ambient temperature of 70 F and must be further derated if ambient temperature exceeds 70 F (21 C). (2) Length is measured from the bottom of the threaded connection or gasket surface of the flange to the bottom of the seal. Please refer to the TSM and FSM drawings. 5
6 January 2015 Specifications Functional specifications Maximum working pressure limits Table 2. Maximum Working Pressure Limits Range Rosemount 3051S_TG, Rosemount 3051T, Rosemount 2051T and Rosemount psig (2,07 bar) 2 60 psig (4,14 bar) Temperature limits Transmitter temperature limits 40 to 185 F (-40 to 85 C) With LCD display (1) : -40 to 175 F (-40 to 80 C) With option code P0: -20 to 185 F (-29 to 85 C) (1) LCD display may not be readable and LCD updates will be slower at temperatures below -4 F (-20 C). Fill fluid temperature limits Table 3. Fill Fluid Specifications Fill fluid Specific gravity at 77 F (25 C) Coeff. of therm. exp. (cc/cc/ C) Viscosity at 77 F (25 C) (Centistokes) Temperature limits Silicone Glycerin and Water to 401 F (-45 to 205 C) 5 to 203 F (-15 to 95 C) Physical specifications Materials of construction Seal Diaphragm: 321 SST Capillary: 316 SST Capillary rmor: 304 SST or PVC-Coated 304 SST Submersible Seal weight lbs. (kg.): 1.2 lbs. (0.54 kg.) Material selection Emerson provides a variety of Rosemount products with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product materials, options, and components for the particular application. Emerson Process Management is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product options, configuration, or materials of construction selected. 6
7 January 2015 Dimensional Drawings Figure 1. 2D Drawing Figure 2. 3D Drawing (40.77) C L 3.57 (90.7) Dimensions are in inches (millimeters). Figure 3. with Optional Screen Insert 7
8 January 2015 Figure 4. Rosemount Submersible Seal Threaded (TSM Process Connection) Side View Flanged (FSM Process Connection) Side View Measurement Length Measurement Length Dimensions are in inches (millimeters). 8
9 January 2015 Figure 5. Rosemount 3051S_T with Submersible Seal Threaded Connection PlantWeb Housing Front View 4.20 (107) Junction Box Housing Front View 4.20 (107) 6.88 (174) Wireless Housing Front View B C (204) 8.04 (204) 3.55 (90.1) 4.20 (107) (283) Side View 5.21 (132) 4.55 (116) Side View 3.45 (88) 6.88 (174) Side View 6.71 (170) 6.05 (155) 8.19 (208) Dimensions are in inches (millimeters).. Capillary Connection B. External ntenna C. External Range External ntenna 9
10 January 2015 Figure 6. Rosemount 3051T with Submersible Seal Threaded Connection Standard 4.1 (105) 5.32 (135) 4.45 (113) 7.2 (183) Wireless Housing 4.22 (107.1) 5.62 (142.9) 7.49 (190.3) B Dimensions a re in Inches (millimeters).. Capillary Connection B. U-Bolt Bracket 10
11 January 2015 Figure 7. Rosemount 2051T with Submersible Seal Threaded Connection Standard 3.85 (98) 5.66 (144) 5.20 (132) 4.36 (111) B 7.15 (182) C D E Wireless Housing 4.22 (107.1) 5.62 (142.9) 7.49 (190.3) F. Capillary Connection B. Fieldbus Display Cover C. HRT Display Cover D. Transmitter Circuitry E. terminal Connections F. U-Bolt Bracket Dimensions a re in Inches (millimeters). 11
12 January 2015 Figure 8. Rosemount 2088 with Submersible Seal Threaded Connection 5.0 (127) 4.3 (110) Max D 3.9 (99) 4.7 (120) G B E 5.75 (146) Typical C F F (20) Clearance for Cover Removal B. 2 X 1/2-14 NPT Conduit Connection C. Terminal Connection D. Optional Display Cover E. Transmitter Circuitry F. Capillary Connection G. Certifications Tag Dimensions are in Inches (millimeters). 12
13 January
14 , Rev BB Product Data Sheet January 2015 Rosemount World Headquarters Emerson Process Management 6021 Innovation Blvd Shakopee, MN 55379, US or North merica Regional Office Emerson Process Management 8200 Market Blvd. Chanhassen, MN 55317, US or Latin merica Regional Office Emerson Process Management 1300 Concord Terrace, Suite 400 Sunrise, Florida, 33323, US Europe Regional Office Emerson Process Management Europe GmbH Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland +41 (0) (0) sia Pacific Regional Office Emerson Process Management sia Pacific Pte Ltd 1 Pandan Crescent Singapore [email protected] Middle East and frica Regional Office Emerson Process Management Emerson FZE P.O. Box 17033, Jebel li Free Zone - South 2 Dubai, United rab Emirates [email protected] Standard Terms and Conditions of Sale can be found at \terms_of_sale. The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. HRT and WirelessHRT are registered trademarks of the HRT Communication Foundation. FOUNDTION fieldbus is a trademark of the Fieldbus Foundation. PROFIBUS is a registered trademark of PROFINET International (PI). ll other marks are the property of their respective owners Rosemount Inc. ll rights reserved.
Rosemount 1199 Submersible Seal
Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and
Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications
Reliable Pressure Measurement with Remote Diaphragm Reliable Pressure Measurement with Remote Diaphragm Introduction............................................................... page 1 Rosemount 3051S
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
1.1 Fill fluids. Rosemount DP Level Fill Fluid Specifications July 2015. Technical Note 00840-2100-4016, Rev DB
Rosemount DP Level Fill Fluid Specifications 1.1 Fill fluids Silicone 2 Silicone 2 for Vacuum Applications Silicone 74 Silicone 74 for Vacuum Applications Silicone 75 Silicone 75 for Vacuum Applications
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
Rosemount Manifolds. Product Data Sheet August 2016 00813-0100-4733, Rev PE. Factory assembled, leak-tested, and calibrated
Product Data Sheet ugust 2016 00813-0100-4733, Rev PE Rosemount Manifolds Factory assembled, leak-tested, and calibrated Full breadth of offering including integral, in-line, and conventional Integral
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
Replacing Displacers with Guided Wave Radar
ROSEMOUNT GUIDED WAVE RADAR Replacing Displacers with Guided Wave Radar KEY POINTS Mounting flanges vary by displacer supplier Probe must extend the of the displacer chamber Single rigid probes are the
THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR
THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR Level measurements where you need them, however remote "Research 80% indicates that nearly of production downtime is preventable..." Ian Nimmo, Founder of the
Rosemount 5708 3D Solids Scanners for Bulk Solids Inventory and Financial Reporting
Rosemount 5708 3D Solids Scanners for Bulk Solids Inventory and Financial Reporting 1 Introduction This technical note provides an overview of the difficulties with inventory and financial reporting of
EMERSON S ROSEMOUNT PROJECT MANAGEMENT OFFICE. Delivering project success for your instrumentation
EMERSON S ROSEMOUNT PROJECT MANAGEMENT OFFICE Delivering project success for your instrumentation One Less Project YOUR INSTRUMENTATION IS ON TRACK. Capital projects always come down to the details. The
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
Rosemount 708 Wireless Acoustic Transmitter
Product Data Sheet January 2015 00813-0100-4708, Rev BB Rosemount 708 Wireless Acoustic Transmitter Improve energy efficiency and environmental compliance with acoustic monitoring of steam traps and pressure
Rosemount 751 Field Signal Indicator
Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available
Rosemount DP Level Transmitters and 1199 Diaphragm Seal System
Rosemount DP Level Transmitters and 1199 Diaphragm Seal System Product Data Sheet May 2016 00813-0100-4016, Rev RA Applications Level, flow, pressure, interface, density Extreme hot and cold temperatures
Rosemount 248 Wireless Temperature Transmitter
Rosemount 248 Wireless Temperature Transmitter Product Data Sheet May 2016 00813-0100-4248, Rev DB Standard temperature transmitter offers a wireless solution for process monitoring Optimize plant efficiency
LEVEL AND VOLUME MEASUREMENTS OF BULK SOLIDS
LEVEL AND VOLUME MEASUREMENTS OF BULK SOLIDS Taking the guesswork out of solids level measurement 1 Measuring powders and solids isn t easy. Just getting a level reading is a challenge, but you really
Monitoring Water Quality For Today s Demanding World
Monitoring Water Quality For Today s Demanding World Visualize Analyze Optimize EMERSON PROCESS MANAGEMENT BRINGING WATER QUALITY MONITORING TO A WHOLE NEW LEVEL WHAT MATTERS MOST: MAKE IT SAFE Like never
General Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided
Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers
Technical Note 84-3-424, Rev CA September 212 Rosemount Radar Transmitters Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers INTRODUCTION This document provides a guideline
Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued
Product Data Sheet December 2012 00813-0100-4738, Rev JB Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued The Proven Leader in MultiVariable Measurement Industry leading
Level Instrumentation for the Refining Industry
Level Instrumentation for the Refining Industry Moving to a Higher Level Performance Delivering Results for You and Your Plant The Power to Deliver Results Rosemount level devices power Emerson s PlantWeb
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
Smart Wireless Solutions. Intelligent Well Production Starts Here
Smart Wireless Solutions Intelligent Well Production Starts Here Enable the intelligent field Apply Smart Wireless from wellhead to the operations center Automate Hundreds of Wells or a Few Emerson s
Baumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices
White Paper Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices EMERSON WIRELESS NETWORKS: PERVASIVE FIELD NETWORKS PFN Pervasive Field Networks (PFN) are a straight forward
Quick Start Guide 00825-0100-4764, Rev DA March 2014. Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator
Quick Start Guide 00825-0100-4764, Rev DA Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator Quick Start Guide NOTICE This document provides basic guidelines for the Rosemount 8714D. It
Baumann 24003 3 Way Bronze or Stainless Steel Control Valve
Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control
Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters
July 10, 2007 - Page 1 Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters General The Bristol 5453-10G indicating pneumatic pressure controller with 624-II control unit, from Emerson
Baumann 81000 Mikroseal Control Valve
Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where
Density Measurement. Technology: Pressure. Technical Data Sheet 00816-0100-3208 INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS
Technical Data Sheet 00816-0100-3208 Density Measurement Technology: Pressure INTRODUCTION Pressure and differential pressure transmitters are often used to measure the density of a fluid. Both types of
SupportNet Technical Services
TM SupportNet Technical Services Help is Just a Mouse Click Away Introducing SupportNet Technical Services Now you can get technical support for your ROC, FloBoss, Bristol, and ControlWave brand products
Import the Gateway Certificate to the Browser
Import the Gateway Certificate to the Browser To remove the security certificate warning page during login the Gateway web interface by importing the Gateway certificate into the Internet Explorer and/or
Baumann 24000 Little Scotty Bronze Control Valve
24000 Valve Product Bulletin Baumann 24000 Little Scotty Bronze Control Valve Baumann Little Scotty industrial control valves are intended for general utility service in pressure, flow, and temperature
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Rosemount 214C Temperature Sensors
Product Data Sheet November 2015 00813-0500-2654, Rev AA Rosemount 214C Temperature Sensors Primary product benefits igh accuracy resistance temperature detectors (RTD) offered in single and dual element
Fisher 657 and 667 Diaphragm Actuators
657 and Actuators Product Bulletin Fisher 657 and Diaphragm Actuators Fisher 657 and spring-opposed diaphragm actuators position the valve plug in the valve in response to varying controller or valve positioner
Fisher 377 Trip Valve
377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls
Electromagnetic Flow Meter
Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are
1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration
SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration FBSPAKMSWAEN Technical Information SUPRApak Multi-Stack Series-WA housings are designed for use with SUPRApak
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
Rosemount 2088 Absolute and Gage Pressure Transmitter
Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.075% with High Accuracy option Lightweight, compact design for cost effective installation Protocols
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Quick Start Guide 00825-0200-4410, Rev DA June 2016. Emerson Smart Wireless Gateway 1410
Quick Start Guide 00825-0200-4410, Rev DA Emerson Smart Wireless Gateway 1410 Quick Start Guide NOTICE This guide provides basic guidelines for the Smart Wireless Gateway 1410 (Gateway). It does not provide
Rosemount 2088 Absolute and Gage Pressure Transmitter
Product Data Sheet August 2015 00813-0100-4690, Rev PC Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.065% with High Accuracy option Lightweight, compact design for cost-effective
Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)
Free Floating ever rain Traps For oads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar) iquid rainers Table -14. Maximum Operating Pressures for Handling ifferent Specific Gravity iquids
Mobrey Hydrastep and Hydratect
Product Data Sheet August 2015 BP2468, Rev EA Mobrey Hydrastep and Hydratect Water/Steam Monitoring Systems High clarity electronic gauging system for steam drums with options of local and remote indication
Stainless Steel Valves For the Sanitary Industries
www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM
SLAM-SHUT VALVE Type OSE Process Management TM DESCRIPTION The purpose of the OSE slam shut valve is to totally and rapidly cut off gas flow when the outlet pressure exceeds or drops below the setting.
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
289 Series Spring-Loaded Relief Valves
October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The
Emerson Smart Wireless Gateway
Product Data Sheet August 2015 00813-0200-4420, Rev GB Emerson Smart Wireless Gateway Gateway connects wireless self-organizing networks with any host system Easy configuration and management of self-organizing
Rosemount 3051 Pressure Transmitter
Rosemount 3051 Pressure Transmitter Product Data Sheet September 2014 00813-0100-4001, Rev SA With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Emerson Smart Wireless Gateway Solutions
Product Data Sheet August 2014 00813-0300-4410, Rev AB Emerson Smart Wireless Gateway Solutions Gateway connects the WirelessHART self-organizing networks with any host system Easy configuration and management
Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter
Ed.15.01 Design Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Standard 4026/60H Pressure rate PN 40
Micro Motion ELITE CMFS Series Meter
Revolutionize your Coriolis measurement technology Micro Motion ELITE CMFS Series Meter Introducing Emerson s Micro Motion Elite CMFS Series METER Our ELITE CMFS meter delivers unmatched, real-world performance
S-series SQ Controller
DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced
ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors
Installation Instructions P/N MMI-20015054, Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations Note: For hazardous installations
Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions
DVC6200 Digital Valve Controller Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions Digital Valve Controller Configuration (1) Mounting Figure Page DVC6200 DVC6200 SIS DVC6200f
Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
ROC800-Series Advanced Pulse Module
ROC800:APM Product Data Sheet D301231X012 May 2014 ROC800-Series Advanced Pulse Module The Advanced Pulse Module (APM) for the ROC800-Series Remote Operations Controller (ROC800) provides advanced functionality
Baumann 24000SB Barstock Control Valve
Instruction Manual 24000SB Valve Baumann 24000SB Barstock Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Disassembly...
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
TECHNICAL BULLETIN. Kämmer LinedFlow - 132000 Corrosive Application Valves. Experience In Motion FCD KMENTB3221-01 04/12
TECHNICAL BULLETIN Kämmer LinedFlow - 132000 Corrosive Application Valves FCD KMENTB3221-01 04/12 Experience In Motion Description ¼-inch NPT test port Large guided stem area Bellows seal eliminates stem
1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids
PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal
Rosemount 3051S Series of Instrumentation
Product Data Sheet October 2014 00813-0100-4801, Rev TA Rosemount 3051S Series of Instrumentation Scalable pressure, flow, and level solutions Innovation reaching across your operation With the Rosemount
Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Model 3051 Pressure Transmitter with HART Protocol
Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure
Type 119 Control Valve
Instruction Manual Form 5204 Type 119 December 2009 Type 119 Control Valve Introduction Scope of the Manual This instruction manual provides installation, spring adjustment, maintenance, and parts information
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
800-348-8467 www.fittingsunlimited.com
Thread and Port Identification Guide 800-348-8467 www.fittingsunlimited.com INDEX Index... 1 Explanation of Symbols... 2 How to Measure Threads... 3-4 Metric vs English Threads... 5 North American Connections
Handling Freescale Pressure Sensors
Freescale Semiconductor Application Note Rev 3, 11/2006 Handling Freescale Pressure by: William McDonald INTRODUCTION Smaller package outlines and higher board densities require the need for automated
Trunnion-Design Ball Valves
Trunnion-Design Ball Valves 12" 20" (DN 300 500) Series 7150 12" (DN 300) Series 730S 12" 20" (DN 300 500) Series 7300 14" 24" (DN 350 600) Series 9150 14" 24" (DN 350 600) Series 9300 Installation, Maintenance
Best Practices for Reducing Transmitter Life Cycle Costs
Best Practices for Reducing Transmitter Life Cycle Costs RESULTS Eliminate on-site calibration and lower total installed costs by purchasing calibrated transmitters Eliminate unnecessary calibration and
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3
Backflush filter R8-30W
Backflush filter R8-30W With internal pressure segment cleaning, rated pressure to 40 bar (580 psi) Connection sizes: DN 200 to DN 500, welded design 1. Features Powerful, fully automatic filtration _
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
Turbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.
Instruction Sheet PN 51A-397/rev.F January 2011 Model 397 ph Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS MODEL 397 PERFORMANCE
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
OpenEnterprise. Lifecycle Services
TM OpenEnterprise Lifecycle Services Emerson offers a comprehensive Lifecycle Services approach to help our customers achieve maximum business value and operational excellence Lifecycle Services are Emerson
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
ANNUBAR FLOW CALCULATION PROGRAM (For the FloBoss 103) User Manual (QER 04Q019)
Flow Computer Division ANNUBAR FLOW CALCULATION PROGRAM (For the FloBoss 103) User Manual (QER 04Q019) Form A6159 September 2004 Revision Tracking Sheet September 2004 This manual may be revised from time
CHATILLON DG Series Mechanical Force Gauge. Operating Instructions
Instruction Manual NC002737 Feb 2003 Issue 1 CHATILLON DG Series Mechanical Force Gauge Operating Instructions The DG Series mechanical force gauge is ideal for a wide range of force testing applications.
Tyco PremiAir Pneumatic Actuators
A comprehensive range of pneumatic actuators, conforming to EN ISO 5211, providing compact, reliable and economical powered operation for all types of quarter turn valves. Features Mounting to valve either
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage