Rosemount 702 Wireless Discrete Transmitter
|
|
|
- Daniela Evans
- 9 years ago
- Views:
Transcription
1 Product Data Sheet August , Rev JB Rosemount 702 Wireless Discrete Transmitter An installation-ready solution that provides dual channel, discrete input, discrete output, or leak detection input options Discrete single or dual switch input with logic for limit contact and opposing contact applications Momentary inputs are continuously measured between wireless updates Dual channels are each configurable for discrete input or discrete output Self-organizing network delivers information rich data with >99% data reliability
2 Rosemount 702 Wireless Discrete Transmitter August 2016 Emerson s Smart Wireless Solution IEC (WirelessHART )... the industry standard Self-organizing, adaptive mesh routing No wireless expertise required, network automatically finds the best communication paths The self-organizing, self-healing network manages multiple communication paths for any given device. If an obstruction is introduced into the network, data will continue to flow because the device already has other established paths. The network will then lay in more communication paths as needed for that device. Emerson s Smart Wireless Reliable wireless architecture Standard IEEE radios 2.4 GHz ISM band sliced into 15 radio channels Time synchronized channel hopping to avoid interference from other radios, Wi-Fi, and EMC sources and increase reliability Direct sequence spread spectrum (DSSS) technology delivers high reliability in challenging radio environment SmartPower solutions Optimized Emerson instrumentation, both hardware and software, to extend power module life Intrinsically safe power module allows field replacements without removing the transmitter from the process, keeping personnel safe, and reducing maintenance costs. Contents Ordering Information Specifications Product Certifications Dimensional Drawings
3 August 2016 Rosemount 702 Wireless Discrete Transmitter Ordering Information Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 5 for more information on material selection. Table 1. Rosemount 702 Wireless Discrete Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Product description 702 Discrete transmitter Transmitter type D Wireless field mount Output X Wireless Measurement 32 Discrete dual input (dry contact), detects momentary inputs and counts 42 Discrete dual input or output, configurable 61 (1) Liquid hydrocarbon detection (for use with TraceTek fast fuel sensor or TraceTek sensing cable) Housing D Dual compartment housing - aluminum E Dual compartment housing - SST Conduit threads 1 1 /2 14 NPT Certifications Measurement option codes I5 FM intrinsically safe, Non-incendive, and Dust ignition-proof 32, 61 I6 CSA intrinsically safe 32, 61 I1 ATEX intrinsically safe 32, 61 IU ATEX intrinsically safe for zone 2 32, 42 I7 IECEx intrinsically safe 32, 61 IY IECEx intrinsically safe for zone 2 32, 42 I4 TIIS intrinsically safe 32 I3 China intrinsically safety 32 N5 FM division 2, Non-incendive 32, 42 N6 CSA division 2, Non-incendive 32, 42 NA No approval 32, 42, 61 Wireless options Wireless update rate, operating frequency and protocol WA3 User configurable update rate, 2.4 GHz DSSS, IEC (WirelessHART) 3
4 Rosemount 702 Wireless Discrete Transmitter August 2016 Table 1. Rosemount 702 Wireless Discrete Transmitter Ordering Information The Standard offering represents the most common options. The starred options ( ) should be selected for best delivery. The Expanded offering is subject to additional delivery lead time. Omni-directional wireless antenna and SmartPower solutions (2) WK1 External antenna, adapter for black power module (I.S. Power module sold separately) WM1 Extended range, external antenna, adapter for black power module (I.S. Power module sold separately) WJ1 WN1 (3) Remote antenna, adapter for black power module (I.S. Power module sold separately) High-gain, remote antenna, adapter for black power module (I.S. Power module sold separately) Other options (include with selected model number) Extended product warranty WR3 3-year limited warranty WR5 5-year limited warranty Display (1) M5 LCD display Mounting bracket B4 Universal L mounting bracket for two inch pipe mounting - SST bracket and bolts Configuration C1 Factory configure date, Descriptor, Message fields, and Wireless Cable gland G2 Cable gland (7.5 mm to 11.9 mm) G4 (4) Thin wire cable gland (3 mm to 8 mm) Switches and kits SS01 Universal safety shower/eyewash kit with UL switches SS02 Universal safety shower/eyewash kit for insulated pipe with UL switches SS03 Universal safety shower/eyewash kit with CSA switches SS04 Universal safety shower/eyewash kit for insulated pipe with CSA switches Typical model number: 702 D X 22 D 1 NA WA3 WK1 M5 1. LCD Display not available for option code Black power module must be shipped separately, order Model 701PBKKF or Part number Limited availability, consult factory for details. 4. Thin wire cable gland is preferred for measurement option 61. Table 2. Spare Parts and Accessories Universal safety shower/eyewash kit with UL switches Universal safety shower/eyewash kit for insulated pipe with UL switches Universal safety shower/eyewash kit with CSA switches Universal safety shower/eyewash kit for insulated pipe with CSA switches 4
5 August 2016 Rosemount 702 Wireless Discrete Transmitter Specifications Functional specifications Discrete input Single or dual SPST dry contacts, single SPDT dry contacts or leak detection. To maintain I.S. ratings, contacts must be limited to simple switches or leak detection only. Switching threshold, measurement option code 32 and 42 Open > 100 K Ohm Closed < 5 K Ohm Momentary discrete input, measurement option code 32 and 42 Detects momentary discrete inputs of 10 millisecond or more duration. At each wireless update, device reports current discrete state and accumulating count of close-open cycles. Accumulating count registers from 0 to 999,999, then re-sets to zero. Discrete output, measurement option Code 42 Maximum rating: 26 Vdc, 100 ma On resistance: typical 1 Ohm Wireless output IEC (WirelessHART) 2.4 GHz DSSS Radio frequency power output from antenna External (WK option) antenna: Maximum of 10 mw (10 dbm) EIRP Extended range, external (WM option) antenna: Maximum of 18 mw (12.5 dbm) EIRP Remote (WJ option) antenna: Maximum of 17 mw (12.3 dbm) EIRP High-gain, remote (WN option) antenna: Maximum of 40 mw (16 dbm) EIRP Local display (1) The optional integral LCD display can show discrete state and diagnostic information. Display updates at each wireless update. 1. The option for a local display is not available with option 61, Liquid hydrocarbon leak detection. Humidity limits 0 100% relative humidity Wireless update rate, measurement option code 32, 42 User selectable, 1 sec. to 60 min. Wireless update rate, measurement option code 61 User selectable, 4 sec. to 60 min. Physical specifications Material selection Emerson provides a variety of Rosemount products with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser s sole responsibility to make a careful analysis of all process (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product materials, options, and components for the particular application. Emerson Process Management is not in a position to evaluate or guarantee the compatibility of the process fluid or other process with the product options, configuration, or materials of construction selected. Electrical connections Wireless power module Replaceable, Intrinsically Safe Lithium-Thionyl Chloride power module with PBT polymer enclosure. Ten year life at one minute update rate. (1) 1. Reference conditions are 70 F (21 C), and routing data for three additional network devices. Note Continuous exposure to ambient temperature limits -40 F or 185 F (-40 C or 85 C) may reduce specified power module life by less than 20 percent. Switch terminals Screw terminals permanently fixed to terminal block Field Communicator connections Communication Terminals Clips permanently fixed to terminal block 5
6 Rosemount 702 Wireless Discrete Transmitter August 2016 Materials of construction Enclosure Housing: low-copper aluminum, or stainless steel Paint: Polyurethane Cover O-ring: Buna-N Terminal Block and Power Module Pack PBT Antenna PBT/PC integrated omni-directional antenna Conduit entries 1 /2 14 NPT Weight Low-copper aluminum: 702 without LCD lb (2.0 kg) 702 with M5 LCD lb (2.1 kg) Stainless steel: 702 without LCD display lb (3.6 kg) 702 with M5 LCD display lb (3.7 kg Enclosure ratings NEMA 4X and IP66/67 Mounting Transmitters may be attached directly to switch, brackets also permit remote mounting. See Dimensional Drawings on page 17. Wireless output unaffected when tested per the requirements of IEC field with general application or pipeline with low vibration level (10 60 Hz 0.15mm displacement peak amplitude/ Hz 2g). Temperature limits Description Operating limit Storage limit Without LCD display With LCD display -40 to 185 F -40 to 85 C -4 to 175 F -20 to 80 C Dry contact switch inputs, measurement option code 32, and 42 Terminal block connections The Rosemount 702 has a pair of screw terminals for each of two channels, and a pair of communication terminals. These terminals are labeled as follows: CH1+: Channel one positive CMN: Common CH2+: Channel two positive CMN: Common COMM: Communication terminals Figure 1. Terminal Block Connections -40 to 185 F -40 to 85 C -40 to 185 F -40 to 85 C Performance specifications Electromagnetic compatibility (EMC) Meets all industrial environment requirements of EN61326 and NAMUR NE-21. Maximum deviation <1% span during EMC disturbance. (1) Vibration effect Wireless output unaffected when tested per the requirements of IEC field or pipeline with high vibration level (10 60 Hz 0.21mm displacement peak amplitude/ Hz 3g). 1. During surge event device may exceed maximum EMC deviation limit or reset; however, device will self-recover and return to normal operation within specified start-up time. 6
7 August 2016 Rosemount 702 Wireless Discrete Transmitter Wireless output specifications Dry contact switch inputs, measurement option code 32, and 42 Single input or dual input independent The Rosemount 702 will accept the input from one or two single pole single throw switches on inputs CH1 and CH2. The wireless output of the transmitter will be both a primary variable (PV) and a secondary variable (SV). The PV is determined by the CH1 input. The SV is determined by the CH2 input. A closed switch drives a TRUE output. An Open switch drives a FALSE output. Dual input, limit contact logic When configured for Limit Contact Logic, the Rosemount 702 will accept the input from two single pole single throw switches on inputs CH1 and CH2, and will use limit contact logic for the determination of the wireless outputs. Figure 3. Dual Input, Limit Contacts Note Any dry contact input can be inverted by the device, so as to give the opposite effect. This is useful, for instance, if a normally open switch is used to replace a normally closed switch. Figure 2. Single and Dual Input Table 4. Dual Input, Limit Contact Logic Switch inputs Wireless outputs CH1 CH2 PV SV Open Open TRAVEL (0.5) TRAVEL (0.5) Open Closed FALSE (0.0) FALSE (0.0) Closed Open TRUE (1.0) TRUE (1.0) Closed Closed FAULT(NaN) FAULT(NaN) Dual input, opposing contact logic When configured for opposing contact logic, the Rosemount 702 will accept the input from a double pole single throw switch on inputs CH1 and CH2, and will use opposing contact logic for the determination of the wireless outputs. Figure 4. Dual Input, Opposing Contact Table 3. Single or Dual Input, No Logic Switch input Wireless output Switch input Wireless output CH1 PV CH2 SV Closed TRUE (1.0) Closed TRUE (1.0) Open FALSE (0.0) Open FALSE (0.0) 7
8 Rosemount 702 Wireless Discrete Transmitter August 2016 Table 5. Dual Input, Opposing Contact Logic Switch inputs Wireless outputs CH1 CH2 PV SV Open Open FAULT(NaN) FAULT(NaN) Open Closed FALSE (0.0) FALSE (0.0) Closed Open TRUE (1.0) TRUE (1.0) Closed Closed FAULT(NaN) FAULT(NaN) Momentary discrete inputs, measurement option code 32 and 42 The Rosemount 702 is capable of detecting momentary discrete inputs of 10 millisecond or more in duration, regardless of the wireless update rate. At each wireless update, the device reports current discrete state along with an accumulating count of close-open cycles for each input channel. Figure 5. Momentary Inputs and Accumulating Count Figure 6. Reporting of Current Discrete State and Count in AMS Device Manager Variable reporting and mapping The Rosemount 702 will report variables exactly like the previous version of the device (measurement option code 22). In the Enhanced variable reporting mode, the transmitter will provide both current state of the discrete channels, and a count of the discrete state change cycles. Following is a table that shows the variable mapping for both cases. Variable Reporting can be set in AMS Device Manager by going to Configure > Manual Setup > HART. Table 6. Variable Mapping Variable reporting Enhanced Discrete state with count Variable mapping PV SV TV QV CH1 state CH2 state CH1 count Discrete output circuits, measurement option code 42 CH2 count The Rosemount 702 has two channels that can each be configured for discrete input or output. Inputs must be dry contact switch inputs and these were described in a preceding section of this document. Outputs are a simple switch closure to activate an output circuit. The transmitter output does not provide any voltage or current, the output circuit must have power of its own. The transmitter output has maximum switch capacity per channel of 26 volts DC and 100 milliamps. A typical power supply for powering an output circuit can be 24 volts or lower. Note It is very important that the polarity of the output circuit is as shown in the wiring diagrams, with the positive (+) side of the circuit wired to the CH1+ or the CH2 + terminal, and the negative (-) side of the circuit wired to the CMN terminal. If the output circuit is wired backwards, it will remain active (switch closed) regardless of the state of the output channel. Discrete output switch functionality The discrete output of the Rosemount 702 is driven by the host control system, through the Smart Wireless Gateway, and out to the transmitter. The time required for this wireless communication from the Gateway to the transmitter is dependent on many factors, including the size and topology of the network and the total amount of downstream traffic on the wireless network. For a network that is constructed to our best practices, typical delays in communication of a discrete output from the Gateway to the Transmitter are 15 seconds or less. Remember that this delay is only part of the latency that well be observed in a control loop. 8
9 August 2016 Rosemount 702 Wireless Discrete Transmitter Note The output switch functionality of the Rosemount 702 requires that the network is managed by a version 3 Smart Wireless Gateway with v3.9.7 firmware, or a version 4 Gateway with v4.3 or higher firmware installed. Figure 7. Output Circuit Wiring If two output circuits are connected to a single Rosemount 702 Transmitter with a single power supply, both CH + and CMN terminals must be connected to each output circuit. The negative power supply wires must be at the same voltage and connected to both CMN terminals. Figure 10. Dual Output Circuits with One Power Supply Figure 8. Possible Configurations for Both Channel 1 and Channel 2 Switching greater currents or voltages It is important to note that the maximum output switching capacity is 26 volts DC and 100 milliamps. If a greater voltage or current is to be switched, an interposing relay circuit can be used. Figure 11 shows an example of a circuit to switch higher currents or voltages. Figure 11. Wiring an Interposing Relay to Switch Greater Currents or Voltages Special considerations for dual output circuits If both channels are connected to output circuits, it is very important that the CMN terminal of each circuit be at the same voltage. Employing a common ground for both output circuits is one way to ensure that both circuits have CMN terminals at the same voltage. Figure 9. Dual Output Circuits with a Common Ground 9
10 Rosemount 702 Wireless Discrete Transmitter August 2016 Leak sensors, liquid hydrocarbon detection, measurement option code 61 Terminal block connections The liquid hydrocarbon detection configuration is intended for use with the Pentair TraceTek Fast Fuel Sensor, or TraceTek sensing cable. Figure 12. Fuel Sensor Terminal Diagram Figure 14. Fuel Sensor Wiring A B A C D B A. TT-MLC-MC-BLK (Leader cable) B. TT-FFS-100 or TT-FFS-250 (Fast fuel sensor probe) C. TT-MJC-xx-MC-BLK (Optional jumper cable) D. TT-ZBC-xx-MC-BLK (Branch connector) Figure 13. Fuel Sensor Connection Diagram The Rosemount 702 can support up to 500 ft of TraceTek hydrocarbon or solvent sensor cable (TT5000 or TT5001 series). The total amount of sensor cable connected to a single transmitter is not to exceed 500 ft. However, leader cable, jumper cables (if used), and branch connectors are not included in the 500 ft (150 m) limit. See Figure 15 for typical configurations. Figure 15. Fuel Sensor Cable Wiring A B C D F The connections to the Fast Fuel Sensor TraceTek sensing cable are made by matching the appropriately colored wires to the matching colored termination lugs. The Rosemount 702 can support up to three Fast Fuel sensors. These Fast Fuel sensors are connected using TraceTek Modular Leader Cable (TT-MLC-MC-BLK), optional modular jumper cables (TT-MJC-xx-MC-BLK) and branching connectors (TT-ZBC-MC-BLK) as suggested in Figure 14. C A. TT-MLC-MC-BLK (Leader cable) B. TT5000/TT5000 Sensor cable (up to 500 ft) C. TT-MET-MC (End termination) D. TT-MJC-xx-MC-BLK (Optional jumper cable) E. Up to 500 ft TT5000 or TT5001 sensor cable (Total per Rosemount 702) F. TT-ZBC-xx-MC-BLK (Branch connector) E C 10
11 August 2016 Rosemount 702 Wireless Discrete Transmitter Safety Shower and Eye Wash Monitoring The Rosemount 702 Transmitter can be used to monitor safety showers and eye wash stations by using switch kits provided by TopWorx, an Emerson company. These kits are ordered as a part of the Rosemount 702 model code and are available for both insulated and un-insulated pipes. These kits contain the switches, brackets and cables that are necessary to install the transmitter to monitor both the safety shower and the eye wash in a single station. Because each has two input channels, one transmitter can be used to monitor both a safety shower and an eye wash. Each safety shower monitoring kit contains: Two TopWorx GO Switch magnetic proximity switches Safety shower monitoring When the shower valve is activated (valve open) by pulling down on the handle, the TopWorx switch is activated (closed switch) and the Rosemount 702 senses that switch closure. This switch state is then transmitted by the transmitter to the Gateway, which then sends that information to the control host or alert system. When the shower valve is closed, the switch remains in the activated state until it is reset by a technician. The switch can be re-set only by placing a ferrous metal object on the far side of the sensing area of the switch. Figure 16. TopWorx Switch Installed on Safety Shower Two cables, six-foot and 12-foot Two black polymer cable glands Mounting kit for safety shower and eye wash UL and CSA switches Safety shower and eye wash monitoring kits are available with either UL or CSA switches. This designation refers to the ordinary location certification of the GO Switch in the kit. These are not hazardous locations certificates. The Go Switch is regarded as a simple apparatus and does not require its own hazardous locations certificate. Either GO Switch is suitable for installation in hazardous locations when wired to the Rosemount 702 with an appropriate hazardous locations certificate. The CSA GO Switch is for applications in Canada, the UL GO Switch is for applications in all other world areas. Installation drawings and instructions Figure 17. Detail of Switch Installation on Safety Shower Installation drawings and instructions for safety shower and eye wash kits are included in the Rosemount 702 Transmitter Reference Manual, Appendix D (document number ). This manual can be downloaded at the Rosemount 702 Transmitter product page: -702-Discrete. 11
12 Rosemount 702 Wireless Discrete Transmitter August 2016 Figure 18. Safety Shower Valve in Activated Position Figure 20. Eye Wash in Activated Position Eye wash monitoring When the eye wash valve is activated (valve open) by pushing down on the hand paddle, the TopWorx switch is activated (closed switch) and the Rosemount 702 senses that switch closure. This switch state is then transmitted by the transmitter to the Gateway, which then sends that information to the control host or alert system. When the eye wash valve is closed, the switch remains in the activated state until it is reset by a technician. The switch can be re-set only by placing a ferrous metal object on the far side of the sensing area of the switch. Figure 19. TopWorx Switch Installed on Eye Wash Station 12
13 August 2016 Rosemount 702 Wireless Discrete Transmitter Product Certifications Rev 1.0 European Union Directive Information A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EC Declaration of Conformity can be found at. Telecommunication Compliance All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage. FCC and IC This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons. Ordinary Location Certification for FM Approvals As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM Approvals, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Installing in North America The US National Electrical Code (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective codes. USA I5 FM Intrinsic Safety (IS) and Nonincendive (NI) Certificate: Standards: FM Class , FM Class , FM Class , FM Class , ANSI/NEMA Markings: IS CL I, DIV 1, GP 1, A, B, C, D; CL II, DIV 1, GP E, F, G; Class III; Class 1, Zone 0 AEx ia IIC T4; NI CL I, DIV 2, GP A, B, C, D T4; T4(-50 C T a +70 C) when installed per Rosemount drawing ; Type 4X; IP66; Special Conditions for Safe Use (X): 1. The 702 transmitter housing contains aluminum and is considered a potential risk of ignition by impact or friction. Care must be taken into account during installation and use to prevent impact and friction. 2. The surface resistivity of the polymeric antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. 3. For use only with the Model 701P or Rosemount XXXX Smart Power Battery Module. N5 Sensor terminal (option code 32) U o = 6.51 V I o = ma P o = mw C o = uf L o = 198 mh Fuel sensor terminal (option code 61) U o = 7.8 V I o = 92 ma P o = 180 mw C o = 9.2 uf L o = 50 mh FM Nonincendive Certificate: Standards: FM Class , FM Class , FM Class , ANSI/NEMA Markings: NI CL I, DIV 2, GP A, B, C, D T4; T4(-50 C T a +70 C) when installed per Rosemount drawing ; Type 4X; IP66; Special Condition for Safe Use (X): 1. For use only with the Model 701P or Rosemount P/N XXXX SmartPower Battery Module. 13
14 Rosemount 702 Wireless Discrete Transmitter August 2016 Canada I6 14 CSA Intrinsically Safe Certificate: Standards: CAN/CSA Std No. 0-10, CSA Std No. 142-M1987, CAN/CSA Std No , CSA Std No :05 Markings: Intrinsically Safe Class I, Division 1; suitable for Class 1, Zone 0, IIC, T3C; when connected per Rosemount drawing ; Type 4X N6 CSA Class I Division 2 Certificate: Standards: CAN/CSA C22.2 No. 0-10, CAN/CSA C22.2 No. 94-M91, CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No :05 Markings: Suitable for Class 1, Division 2, Groups A, B, C, and D, T3C; Cl. I, Zone 2, IIC, T3C; Europe I1 ATEX Intrinsic Safety Certificate: Baseefa 07ATEX0239X Standards: IEC : 2011, EN : 2012 Markings: II 1 G Ex ia IIC T4 Ga, T4(-60 C T a +70 C) Ex ia IIC T5 Ga, T5(-60 C T a +40 C) For use with Rosemount SmartPower power module part number , or for use with Emerson SmartPower option 701PBKKF. Sensor terminal (option code 32) U o = 6.51 V I o = ma P o = mw C i = uf C OIIC = uf C OIIB = uf C OIIA = 1000 uf Fuel sensor terminal (option code 61) U o = 7.8 V I o = 92 ma P o = 180 mw C i = 10 nf L i = 0 L i = 0 L OIIC = 200 mh L OIIB = 800 mh L OIIA = 1000 mh C OIIC = 9.2 uf C OIIB = 129 uf C OIIA = 1000 uf L OIIC = 4.2 mh L OIIB = 16.8 mh L OIIA = 33.6 mh Special Condition for Safe Use (X): 1. The surface resistivity of the antenna is greater than 1GΩ. To avoid electrostatic change build-up, it must not be rubbed or cleaned with solvents or a dry cloth. IU ATEX Intrinsic Safety for Zone 2 Certificate: Baseefa12ATEX0122X Standards: IEC : 2011, EN : 2012 Markings: II 3G Ex ic IIC T4 Gc, T4(-60 C T a +70 C) Ex ic IIC T5 Gc, T5(-60 C T a +40 C) Special Conditions for Safe Use (X): 1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. 2. The Model 701PB Power Module may be replaced in a hazardous area. The Power Module has surface resistivity greater than 1 GΩ and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up. International I7 Sensor terminal (input) U o = 6.6 V I o = 13.4 ma Switch terminal (output) U i = 26V I i = 100mA P o = 21.8 mw P i = 0.65W C o = 10.9 uf L o = 25 uf N/A IECEx Intrinsic Safety Certificate: IECEx BAS X Standards: IEC : 2011, IEC : 2011 Markings: Ex ia IIC T4 Ga, T4 (-40 C T a +70 C) Ex ia IIC T5 Ga, T5 (-40 C T a +40 C) Switch terminal (option code 32) U o = 6.51 V I o = ma P o = mw C i = uf C OIIC = uf C OIIB = uf C OIIA = 1000 uf N/A Fuel sensor terminal (option code 61) U o = 7.8 V I o = 92 ma P o = 180 mw C i = 10 nf L i = 0 L i = 0 L OIIC = 200 mh L OIIB = 800 mh L OIIA = 1000 mh C OIIC = 9.2 uf C OIIB = 129 uf C OIIA = 1000 uf L OIIC = 4.2 mh L OIIB = 16.8 mh L OIIA = 33.6 mh
15 August 2016 Rosemount 702 Wireless Discrete Transmitter Special Conditions for Safe Use (X): 1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. 2. The Model 701PB Power Module may be replaced in a hazardous area. The Power Module has surface resistivity greater than 1 GΩ and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up. 3. The 702 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a Zone 0 area. IY IECEx Intrinsic Safety for Zone 2 Certificate: IECEx BAS X Standards: IEC : 2011, IEC : 2011 Markings: Ex ic IIC T4 Gc, T4 (-40 C T a +70 C) Ex ic IIC T5 Gc, T5 (-40 C T a +40 C) China I3 China Intrinsic Safety Certificate: GYJ X Standards: GB , GB , GB Markings: (option 32, 61): Ex ia IIC T4/T5 Ga, T4(-60 C T a +70 C)/T5(-60 C T a +40 C) (option 32, 42): Ex ic IIC T4/T5 Gc, T4(-60 C T a +70 C)/T5(-60 C T a +40 C) Switch terminal (option code 32) Terminal (option code 42) Sensor Switch Fuel sensor terminal (option code 61) U o = 6.6 V U o = 6.6 V U i = 26 V U o = 7.8 V I o = 13.4 ma I o = 13.4 ma I i = 100 ma I o = 92 ma P o = 21.8 mw P o = 21.8 mw P i = 650 mw P o = 180 mw Sensor terminal (input) U o = 6.6 V I o = 13.4 ma P o = 21.8 mw C o = 10.9 uf L o = 25 uf Switch terminal (output) U i = 26 V I i = 100 ma P i = 0.65 W N/A N/A C OIIC = uf C o = uf L i =0 C o = 9.29 uf C OIIB = uf N/A N/A N/A C OIIA = 1000 uf N/A N/A N/A L OIIC = 200 mh L o = mh N/A L o =2 mh L OIIB = 800 mh N/A N/A N/A L OIIA = 1000 mh N/A N/A N/A Special Condition for Safe Use (X): 1. See certificate for special conditions. Special Conditions for Safe Use: 1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth. 2. The Model 701PB Power Module may be replaced in a hazardous area. The Power Module has surface resistivity greater than 1 GΩ and must be properly installed in the wireless device enclosure. Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build-up. 3. The 702 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a Zone 0 area. Japan I4 TIIS Intrinsic Safety Certificates: TC20411 (Option 32) TC20412 (Option 61) Markings: Ex ia IIC T4 (-20 C T a +60 C) 15
16 Rosemount 702 Wireless Discrete Transmitter August 2016 EAC - Belarus, Kazakhstan, Russia IM EAC Intrinsic Safety Certificate: RU C-US.Gb05.B Markings: (option 32, 61): 0Ex ia IIC T4/T5 X, (option 32, 42): 2Ex ic IIC T4/T5 X, T4 (-60 C T a +70 C)/T5(-60 C T a +40 C) Switch terminal (option code 32) Terminal (option code 42) Sensor Switch Fuel sensor terminal (option code 61) U o = 6.6 B U o = 6.6 B U i B = 26 B U o = 7.8 B I o = 13.4 ma I o = 13.4 ma I i = ma = 100 ma I o = 92 ma P o = 21.8 mb T P o = 21.8 mb T P i, B T = 650 mb T P o = 180 mb T C i = 216 HΦ C i = 216 HΦ N/A C i = 10HΦ C OIIC = 23.78MKΦ C OIIC = 23.78MKΦ N/A N/A C OIIB = MKΦ C OIIB = MKΦ N/A N/A C OIIA = 1000MKΦ C OIIA = 1000MKΦ N/A N/A L i = 0 L i = 0 L i = 0 L i = 0 L OIIC = 200MΓ H L OIIC = 200MΓ H N/A N/A L OIIB = 800MΓ H L OIIB = 800MΓ H N/A N/A L OIIA = 1000MΓ H L OIIA = 1000MΓ H N/A N/A Special Condition for Safe Use (X): 1. See certificate for special conditions. Combination KQ Combination of I1, I5, and I6 16
17 August 2016 Rosemount 702 Wireless Discrete Transmitter Dimensional Drawings Figure 21. Rosemount 702 Transmitter A [107] 3.61 [92] [284] [315] 6.71 [170] 6.05 [154] 5.51 [140] A. Extended range external antenna Dimensions are in inches (millimeters). Figure 22. Rosemount 702 Transmitter Mounting Configurations with Optional Mounting Bracket A B 6.20 (158) A. 2-in. U-bolt for pipe mounting B. 1-in. U-bolt for transmitter mounting Dimensions are in inches (millimeters). 17
18 Rosemount 702 Wireless Discrete Transmitter August 2016 Figure 23. Rosemount 702 Wireless Transmitter A [170] [285] 4.20 [107] 7.81 [198] [284] A 6.05 [154] 7.88 [200] D B C E.42 [11] A. 2.4 GHz/WirelessHART extended range antenna B. Ground screw assembly C. Digital display cover D. Field terminals E. Transmitter electronics Dimensions are in inches (millimeters). Figure 24. Rosemount 702 Wireless Transmitter Mounting Configuration with Optional Mounting Bracket A 3.67 [93] A. 2-in. U-bolt for pipe fitting Dimensions are in inches (millimeters). 18
19 August 2016 Rosemount 702 Wireless Discrete Transmitter 19
20 Rosemount 702 Wireless Discrete Transmitter , Rev JB Product Data Sheet August 2016 Global Headquarters Emerson Process Management 6021 Innovation Blvd. Shakopee, MN 55379, USA or North America Regional Office Emerson Process Management 8200 Market Blvd. Chanhassen, MN 55317, USA or Latin America Regional Office Emerson Process Management 1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA Europe Regional Office Emerson Process Management Europe GmbH Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland +41 (0) (0) Asia Pacific Regional Office Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore [email protected] Middle East and Africa Regional Office Emerson Process Management Emerson FZE P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates [email protected] Linkedin.com/company/Emerson-Process-Management Twitter.com/Rosemount_News Facebook.com/Rosemount Youtube.com/user/RosemountMeasurement Google.com/+RosemountMeasurement Standard Terms and Conditions of Sale can be found at: The Emerson logo is a trademark and service mark of Emerson Electric Co. AMS, SmartPower, TopWorx, GO Switch, Rosemount, and Rosemount logotype are trademarks of Emerson Process Management. WirelessHART is a registered trademark of Field Comm Group. TraceTek is a registered trademark of Tyco Thermal Controls LLC or its affiliates. NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association. National Electrical Code is a registered trademark of National Fire Protection Association, Inc. All other marks are the property of their respective owners Emerson Process Management. All rights reserved.
Rosemount 708 Wireless Acoustic Transmitter
Product Data Sheet January 2015 00813-0100-4708, Rev BB Rosemount 708 Wireless Acoustic Transmitter Improve energy efficiency and environmental compliance with acoustic monitoring of steam traps and pressure
Rosemount 248 Wireless Temperature Transmitter
Rosemount 248 Wireless Temperature Transmitter Product Data Sheet May 2016 00813-0100-4248, Rev DB Standard temperature transmitter offers a wireless solution for process monitoring Optimize plant efficiency
Emerson Smart Wireless Gateway Solutions
Product Data Sheet August 2014 00813-0300-4410, Rev AB Emerson Smart Wireless Gateway Solutions Gateway connects the WirelessHART self-organizing networks with any host system Easy configuration and management
Emerson Smart Wireless Gateway
Product Data Sheet August 2015 00813-0200-4420, Rev GB Emerson Smart Wireless Gateway Gateway connects wireless self-organizing networks with any host system Easy configuration and management of self-organizing
Rosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
Quick Start Guide 00825-0200-4410, Rev DA June 2016. Emerson Smart Wireless Gateway 1410
Quick Start Guide 00825-0200-4410, Rev DA Emerson Smart Wireless Gateway 1410 Quick Start Guide NOTICE This guide provides basic guidelines for the Smart Wireless Gateway 1410 (Gateway). It does not provide
Rosemount 751 Field Signal Indicator
Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available
THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR
THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR Level measurements where you need them, however remote "Research 80% indicates that nearly of production downtime is preventable..." Ian Nimmo, Founder of the
Rosemount 1199 Submersible Seal
Product Data Sheet January 2015 00813-0400-4016, Rev BB The Rosemount Submersible Seal design uses innovative DP Level technology to measure level for top-down applications. For this design, the seal and
Rosemount 1199 Submersible Seal
Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications
Reliable Pressure Measurement with Remote Diaphragm Reliable Pressure Measurement with Remote Diaphragm Introduction............................................................... page 1 Rosemount 3051S
Rosemount 248 Temperature Transmitter
Product Data Sheet February 2014 00813-0100-4825, Rev KB Rosemount 248 Temperature Transmitter Basic temperature transmitter offers a reliable solution for temperature monitoring points transmitter design
Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet
October 2014 Page 1 Redundant (WIOC) Fully redundant Wireless solution from to the Smart Wireless Field Link Optional simplex for smaller applications Seamless integration with DeltaV system and AMS Suite.
S-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction
Manual Supplement Rosemount 5300 and 5400 Series Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction Introduction..................................... page S-1 Safety Messages.................................
BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices
March 0 Description The enables new and existing wired smart HART fi eld devices, non-smart analog fi eld devices and remote HART I/O from any supplier to communicate with host applications using technology.
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Model 3051 Pressure Transmitter with HART Protocol
Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure
Quick Start Guide 00825-0100-4764, Rev DA March 2014. Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator
Quick Start Guide 00825-0100-4764, Rev DA Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator Quick Start Guide NOTICE This document provides basic guidelines for the Rosemount 8714D. It
Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas
Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas 34-XY-03-01, May 2012 Function The WG/A5xx is part of the XYR 5000 family of wireless products.
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Fisher 4320 Wireless Position Monitor, with On/Off Control Option
Product Bulletin Fisher Wireless Position Monitor, with On/Off Control Option The Fisher eliminates the need for wiring to an on/off pneumatically actuated valve. It provides a precise wireless feedback
Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices
White Paper Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices EMERSON WIRELESS NETWORKS: PERVASIVE FIELD NETWORKS PFN Pervasive Field Networks (PFN) are a straight forward
S-series SQ Controller
DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)
Product Data Sheet July 2015 00813-0200-2654, Rev KA Rosemount DIN-Style Temperature Sensors and Thermowells (Metric) RTDs (0065) and thermocouples (0185) available to meet any process requirement DIN-style
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Rosemount 214C Temperature Sensors
Product Data Sheet November 2015 00813-0500-2654, Rev AA Rosemount 214C Temperature Sensors Primary product benefits igh accuracy resistance temperature detectors (RTD) offered in single and dual element
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Rosemount 5708 3D Solids Scanners for Bulk Solids Inventory and Financial Reporting
Rosemount 5708 3D Solids Scanners for Bulk Solids Inventory and Financial Reporting 1 Introduction This technical note provides an overview of the difficulties with inventory and financial reporting of
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
DeltaV SISnet Repeater
September 2013 Page 1 The DeltaV SIS platform is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety instrumented function. Fiber-optic
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Rosemount 2088 Absolute and Gage Pressure Transmitter
Product Data Sheet August 2015 00813-0100-4690, Rev PC Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.065% with High Accuracy option Lightweight, compact design for cost-effective
ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors
Installation Instructions P/N MMI-20015054, Rev. AA May 2009 ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors For ATEX-approved sensor installations Note: For hazardous installations
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
CSI 9420 Wireless Vibration Transmitter
Machinery Health Management Product Data Sheet March 2016 CSI 9420 Wireless Vibration Transmitter Accurately monitors vibration and temperature in hard-to-reach locations. Provides complete vibration data
1.1 Fill fluids. Rosemount DP Level Fill Fluid Specifications July 2015. Technical Note 00840-2100-4016, Rev DB
Rosemount DP Level Fill Fluid Specifications 1.1 Fill fluids Silicone 2 Silicone 2 for Vacuum Applications Silicone 74 Silicone 74 for Vacuum Applications Silicone 75 Silicone 75 for Vacuum Applications
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
Flameproof Audible Signal 115 db (A) Series YA90
Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter
Quick Start Guide 00825-0100-4801, Rev MA May 2015 Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol Quick Start Guide May 2015 NOTICE This guide provides
Fisher FIELDVUE DVC2000 Digital Valve
DVC2000 Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC2000 Digital Valve Controller The FIELDVUE DVC2000 digital valve controller is simple to use, compact, and designed for easy mounting.
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
SureCross DX99 Intrinsically Safe (IS) FlexPower Node with Integrated Battery
DX80...B Models SureCross DX99 Intrinsically Safe (IS) FlexPower Node with Integrated Battery Configurable Node with an integrated battery and metal housing for 2 discrete inputs and 2 analog inputs The
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter
Quick Start Guide 00825-0100-4001, Rev. JB Rosemount 3051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc Low Power Protocol Rosemount 3051CF Series Flowmeter Transmitter with 4-20 ma HART and 1-5 Vdc
Inductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS
Fisher 846 Electro-Pneumatic Transducer
846 Transducer Product Bulletin Fisher 846 Electro-Pneumatic Transducer The Fisher 846 electro-pneumatic transducer is a rugged, field-mountable transducer that accepts an electrical input signal and converts
Rosemount 3144P Temperature Transmitter
Product Data Sheet June 2015 00813-0100-4021, Rev NB Rosemount 3144P Temperature Transmitter For every responsibility you have, you are confronted with a number of challenges. You have aggressive production
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)
DVC6200 SIS Digital Valve Controller Product Bulletin Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS) The FIELDVUE DVC6200 SIS digital valve controller is a HART
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System
EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System Instruction Manual DELUXE AND MINI RECEIVER KIT (RX) INSTRUCTIONS " WARNING THIS MANUAL MUST BE READ CAREFULLY BY ALL INDIVIDUALS
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
Differential-Hall-Effect based Sensors Series A5S Overview
A5S Differential-Hall-Effect based Sensors Series A5S Overall View KEY FEATURES Speed range from 0 Hz up to 25 khz (response time < 20 microseconds) Air gap to the target / pole wheel up to 2.5 mm (depending
3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
EMERSON S ROSEMOUNT PROJECT MANAGEMENT OFFICE. Delivering project success for your instrumentation
EMERSON S ROSEMOUNT PROJECT MANAGEMENT OFFICE Delivering project success for your instrumentation One Less Project YOUR INSTRUMENTATION IS ON TRACK. Capital projects always come down to the details. The
Rosemount 2088 Absolute and Gage Pressure Transmitter
Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.075% with High Accuracy option Lightweight, compact design for cost effective installation Protocols
Mobrey Hydrastep and Hydratect
Product Data Sheet August 2015 BP2468, Rev EA Mobrey Hydrastep and Hydratect Water/Steam Monitoring Systems High clarity electronic gauging system for steam drums with options of local and remote indication
Rosemount 644 Temperature Transmitter
Product Data Sheet July 2016 00813-0100-4728, Rev UA Rosemount 644 Temperature Transmitter The most versatile temperature transmitter Reduce complexity and simplify the day to day operations of your diverse
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers
Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers R Description These accelerometers are intended for critical machinery applications where casing acceleration
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C
/Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Foxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
3500/25 Enhanced Keyphasor*Module
3500/25 Enhanced Keyphasor*Module Bently Nevada* Asset Condition Monitoring Description The 3500/25 Enhanced Keyphasor Module is a half-height, two-channel module used to provide Keyphasor signals to the