Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas

Size: px
Start display at page:

Download "Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas"

Transcription

1 Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas 34-XY-03-01, May 2012 Function The WG/A5xx is part of the XYR 5000 family of wireless products. These transmitters cover a wide pressure range, and can be used to monitor a variety of processes and assets in hazardous and remote areas. Since there are no wires to run, the transmitter can be installed and operational in minutes, quickly providing information about the variable being monitored. The Smart Response Manager allows the transmitter to adapt to changing process conditions, allowing greater visibility to process variation. Smart Response Manager allows the user to set thresholds which, when exceeded, cause the transmitter to adjust sampling and data transmission rates. Wireless Transmitters The transmitter combines a high accuracy piezoresistive sensor with a Radio Frequency (RF) transceiver operating in the 900MHz license-free band. Communication is a digital protocol, using Frequency Hopping Spread Spectrum (FHSS). FHSS ensures data integrity by continually switching the carrier wave over a wide range of frequencies. Power is supplied by a C size 3.6 V lithium battery, with an expected lifetime of up to five years. Base Radio Enjoy the benefits of wireless technology today: Improve Product Quality Ensure High Uptime Reduce Maintenance and Operational Costs Meet Regulatory Requirements Enhance Flexibility

2 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 2 Models Gauge Pressure Model # UPPER RANGE LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG / L SS/304 SS WG / L SS/304 SS WG /69 316L SS/304 SS WG / PH/304 SS WG / PH/304 SS Absolute Pressure Model # UPPER RANGE LIMIT PSIA/BAR DIAPHRAGM MATERIAL (wetted parts) WA / L SS/304 SS WA / L SS/304 SS Remote Gauge Pressure without Yagi Model # UPPER RANGE LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG / L SS/316 SS WG / L SS/316 SS WG /69 316L SS/316 SS WG / PH/316 SS WG / L SS/316 SS WG / L SS/316 SS WG / PH /316 SS Remote Gauge Pressure with Yagi Model # UPPER RANGE LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG / L SS/316 SS WG / L SS/316 SS WG /69 316L SS/316 SS WG / PH/316 SS WG / L SS/316 SS WG / L SS/316 SS WG / PH/316 SS

3 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 3 Wireless General Specifications Wireless Communication RF Transmit Power Data Rate 902 MHz 928 MHz Frequency Hopping Spread Spectrum (FHSS) FCC certified ISM license-free band. Every data block transmitted is verified (CRC check) and acknowledged by the Base Radio. 31 mw, 17.8 mw typical. Configurable: 4.8 Kbps, 19.2 Kbps, or 76.8 Kbps. Antenna Omnidirectional Yagi Directional Signal Range Internal 3 omni-directional, ¼ wave, monopole. Up to 2000 feet (600 meters) from Base Radio with clear line of sight.* *Actual range may vary depending on site topography. Length: 18. Gain: 6 dbd. Weight: 1.5 lbs. Polarization: Vertical. Up to 5000 feet (1500 meters) from Base Radio with clear line of sight.* Self Diagnostics Self-checking software and hardware that identifies and reports out of spec conditions, and field unit low battery voltage Site Survey Tools RSSI Link Test Received Signal Strength Indicator displays the RF signal strength in one of seven ranges. Link Test measures the wireless link performance of a transmitter running in normal operating mode. This function looks at wireless performance in both directions, from the transmitter to base radio and vice versa and assigns a rating to that performance or quality of signal. Features Automatic Re-transmit Battery Life Saver The field unit checks with the base radio to insure successful receipt of data. If data was not received, the transmitter retries on the next RF cycle. Ensures communication confidence in the harshest of industrial environments. At the maximum transmit rate this feature is inactive. To save conserve battery power, all field units will attempt to synchronize with the network using the following technique: Time Field Unit Synchronization Attempts and Attempt Delay 0 1 minute Continuous Synchronization attempts 1 10 minutes One attempt with a 10 second delay between attempts minutes One attempt with a 30 second delay between attempts minutes One attempt with a 1-minute delay between attempts 1 12 hours Three-attempt burst with a 5-minute delay between attempts hours Three-attempt burst with a 10-minute delay between attempts hours Three-attempt burst with a 30-minute delay between attempts hours Three-attempt burst with a 1-hour delay between attempts 48 + hours Three-attempt burst with a 2-hour delay between attempts

4 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 4 Operating/Storage Conditions Humidity Temperature Ambient Sensor: Ambient Electronics: Process fluid: Display (Full visibility): Display (Reduced visibility): Storage: 99% RH (non-condensing). -40 to +230 F (-40 to +110 C) -40 to +149/+185 F (-40 to +65/+85 C) (see Model Selection Guide) -40 to +250 F (-40 to +121 C) -4 to +158 F (-20 to +70 C) -40 to +185 F (-40 to +85 C) -58 to +185 F (-50 to +85 C) Device Configuration Parameter Configuration Configuration Panel RF Channel Setup: 1 to 16. Baud Rate: 4.8 Kbps, 19.2 Kbps, 76.8 Kbps. RF ID: 1 to 100. Password. Tag Name (up to 21 characters). Normal Transmit Rate: (1 5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). Normal Sampling Rate: (1 10 sec, 15 sec, 20 sec, 30 sec, 1 min). Abnormal Transmit Rate: (1 5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). Abnormal Sampling Rate: (1 10 sec, 15 sec, 20 sec, 30 sec). Pressure Normal Upper Value: Disabled/Enabled. Enabled to change Sampling and Transmit rates during abnormal process conditions. Pressure Normal Lower Value: Disabled/Enabled. Enabled to change Sampling and Transmit rates during abnormal process conditions. Engineering Units: PSI, bar, mbar, Pa, kpa, Torr, Atm, inh20, inhg, fth20, mmhg, g/cm2, kg/cm2. Pressure Zero. Offset: User defined offset will be transmitted instead of actual value. Trim: Applies a user-defined one- or two-point correction curve to the actual value. Integrated LCD display with membrane switch buttons for local configuration. LCD display is 7-digit (alternating) high contrast, anti-reflective monochrome. Display cycles between pressure level and RF status. Performance Models: WG511, 512, 513, 521, 522, 523, 525, 526, 561, 562, 563, 565, 566 WA515, 516 Accuracy (linearity and hysteresis) ± 0.1% of full span over temperature Combined Zero and Span Stability Less than ± 0.1% of full span per year at 21 C (70 F)

5 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 5 Performance Models: WG514, 524, 564, 519, 529, 569 Reference Span: (Accuracy) TDa: Reference Span: (Temperature) TDt Accuracy: (± % Span) (Reference includes combined effects of linearity, hysteresis and repeatability) Terminal Board Zero Temp Effect: (± % Span per 50 F [28 C]) Combined Zero and Span Temperature Effect: (± % Span per 50 F [28 C]) Thermal Hysteresis (± % Span) = 0.75 Stability (± % Span per year) = psig (172 bar) 1800 psig (124 bar) =0.312 for Process Variable < TDa or =0.110 for Process Variable = or > TDa =0.30 x Process Variable < TDt) =0.10 for Process Variable = or > TDt =0.35 x Process Variable < TDt) =0.15 for Process Variable = or > TDt Physical Specifications Process connections Base Material (bob-wetted) Electronic Housing Vibration and Shock Random Vibration Net weight Electromagnetic Compatibility (CE Compliance) 1/2" - NPTM. 304 SS Lexan V0 Rating and UV Stable. Certified per IEC EN (Vibration) and 2-27 (Shock) Certified to withstand 6 g s, 15 minutes per axis from Hz. Pressure w/o Yagi Remote Sensor w/o Yagi Remote Sensor w/yagi 1 kg (2 lbs.) 6.7 kg (13 lbs.) 7.7 kg (15 lbs.) Operates within Specifications in fields from 80 to 1,000 MHz with Field Strengths to 10 V/m. Meets EN General Immunity Standard and EN Compatibility Emissions Standard. Approvals Environmental protection NEMA 4X, IP 65 Combined FM/CSA FM Intrinsically safe - Class I, Div. 1, Groups A,B,C,D,E,F,G,T4, Class I, Zone 0, AEx ia IIC T4, (Ta = -40 C to +85 C) Enclosure 4 CSA - Intrinsically safe - Class I, Div. 1, Groups A,B,C,D,E,F,G,T4, Class I, Zone 0, Ex ia IIC T4, (Ta = -40 C to +85 C) Enclosure 4 Combined CE/ATEX CE EMC Conformity, ETSI EN Intrinsically Safe, Zone 0/1: Ex II 1 G EEx ia IIC T4 (Ta = -40 C to +65 C) IP65 Non-Sparking, Zone 2: Ex II 3 G EEx na, IIC T6 (Ta = -40 C to +85 C) IP65

6 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 6 Dimensions 97.5/ / / /7.38 mm/inches Integral Remote Sensor w/yagi Remote Sensor

7 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 7 Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: Model Selection Guide 34-XY-16U-01 Issue 13 Page 1 of 2 XYR 5000 Wireless Gauge & Absolute Pressure Transmitters Model Selection Guide Instructions Select the desired key number. Key Number I (Approvals) _ - - II (Options) KEY NUMBER Description Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Span 0-30 psig (2 bar) psig (17.2 bar) psig (69 bar) psig (345 bar) psig (689 bar) Selection WG511 WG512 WG513 WG514 WG519 Availability Absolute Pressure Transmitter Absolute Pressure Transmitter 0-30 psia (2 bar-abs) psia (17.2 bar-abs) WA515 WA516 TABLE I - CERTIFICATION OPTIONS Certificate Approval Type Location or Classification Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4X Class I, Div 2, Groups A,B,C,D; Suitable for Combined FM & CSA ATEX* Nonincendive CL II, III, Div 2, Groups F,G, T4; CL I, Zone 2, AEx na IIC T4; Enclosure Type 4X Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, Ex ia IIC T4; Enclosure Type 4X Class I, Div 2, Groups A,B,C,D; Suitable for Nonincendive CL II, III, Div 2, Groups F,G, T4; CL I, Zone 2, Ex n IIC T4; Enclosure Type 4X Multiple Marking** Ex II 1 G EEx ia IIC T4; Ta -40 to 65 Int. Safe, Zone 0/1, Ex II 3 G EEx nl, IIC T4; Ta -40 to 85 or Non-Sparking, Enclosure IP 65 Zone 2 * See ATEX installation requirements in the Operator's Manual. ** The user must determine the type of protection required for installation of the equipment. The user shall then check the box [ ] adjacent to the type of protection used on the equipment certification label. Once a type of protection has been checked on the label, the equipment shall not then be reinstalled using any of the other certification type. AG 3G b TABLE II - OPTIONS Battery Holder Only - No Battery Included Battery Battery - Standard Included Standard Warranty Warranty Additional Warranty - 1 year Additional Warranty - 2 years 00 B1 00 W1 W2 RESTRICTIONS Restriction Letter Available Only With Not Available With Table Selection Table Selection b Mutually exclusive - select one NOTE: Manuals are provided on CD with each shipment. Manuals may also be downloaded free of

8 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 8 XYR 5000 Wireless Remote Sensor GP Transmitters 34-XY-16U-16 Issue 9 Page 1 of 1 Model Selection Guide Instructions Select the desired key number. Key Number I (Approvals) _ - - II (Options) KEY NUMBER Description Span Selection 0-30 psig (2 bar) WG psig (17.2 bar) WG psig (69 bar) WG psig (345 bar) WG psig (6.9 bar) WG psig (1 bar) WG526 Availability 0-30 psig (2 bar) psig (17.2 bar) psig (69 bar) psig (345 bar) psig (6.9 bar) 0-15 psig (1 bar) WG561 WG562 WG563 WG564 WG565 WG566 TABLE I - CERTIFICATION OPTIONS Certificate Approval Type Location or Classification Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Combined FM & CSA (CSA Pending) ATEX* Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4X Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Groups F,G, T4; CL I, Zone 2, AEx na IIC T4; Enclosure Type 4X Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, Ex ia IIC T4; Enclosure Type 4X Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for b CL II, III, Div 2, Groups F,G, T4; CL I, Zone 2, Ex n IIC T4; Enclosure Type 4X Multiple Marking** Ex II 1 G EEx ia IIC T4; Ta -40 to 65 Int. Safe, Zone 0/1, or Ex II 3 G EEx nl, IIC T4; Ta -40 to 85 3G Non-Sparking, Zone 2 Enclosure IP 65 * See ATEX installation requirements in the Operator's Manual. ** The user must determine the type of protection required for installation of the equipment. The user shall then check the box [ ] adjacent to the type of protection used on the equipment certification label. Once a type of protection has been checked on the label, the equipment shall not then be reinstalled using any of the other certification type. AG TABLE II - OPTIONS Battery Holder Only - No Battery Included Battery Battery - Standard Included Standard Warranty Warranty Additional Warranty - 1 year Additional Warranty - 2 years 00 B1 00 W1 W2 RESTRICTIONS Restriction Available Only With Not Available With Letters Table Selection Table Selection b Mutually exclusive - select one NOTE:

9 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 9 Sales and Service For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below. ASIA PACIFIC (TAC) hfs-tacsupport@honeywell.com Australia Honeywell Limited Phone: +(61) FAX: +(61) Toll Free Toll Free Fax: China PRC - Shanghai Honeywell China Inc. Phone: (86-21) Fax: (86-21) EMEA Honeywell Process Solutions, Phone: or +44 (0) FAX: +44 (0) (Sales) sc-cp-appssalespa62@honeywell.com or (TAC) hfs-tacsupport@honeywell.com NORTH AMERICA Honeywell Process Solutions, Phone: Or (Sales) ask-ssc@honeywell.com or (TAC) hfs-tacsupport@honeywell.com SOUTH AMERICA Honeywell do Brasil & Cia Phone: +(55-11) FAX: +(55-11) (Sales) ask-ssc@honeywell.com or (TAC) hfs-tacsupport@honeywell.com Singapore Honeywell Pte Ltd. Phone: +(65) Fax: +(65) South Korea Honeywell Korea Co Ltd Phone: +(822) Fax: +(822) Specifications are subject to change without notice.

10 XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 10 For More Information Learn more about how Honeywell s XYR 5000 Wireless Gauge and Absolute Pressure Transmitters can be used to monitor a variety of processes, visit our website or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona Tel: or XY May Honeywell International Inc.

WIRELESS INSTRUMENTATION TECHNOLOGY

WIRELESS INSTRUMENTATION TECHNOLOGY BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904

More information

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal

More information

Instructions for copying HART DD files to 375/475 using Field Communicator Easy Upgrade Utility

Instructions for copying HART DD files to 375/475 using Field Communicator Easy Upgrade Utility Instructions for copying HART DD files to 375/475 using Field Communicator Easy Upgrade Utility Document Number: 34-ST-33-66 Effective Date: 5/23/2013 Supersedes: 1/24/2013 Note 1: To copy and use the

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product

More information

Rosemount 708 Wireless Acoustic Transmitter

Rosemount 708 Wireless Acoustic Transmitter Product Data Sheet January 2015 00813-0100-4708, Rev BB Rosemount 708 Wireless Acoustic Transmitter Improve energy efficiency and environmental compliance with acoustic monitoring of steam traps and pressure

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

Microcor Wireless Transmitter (MWT)

Microcor Wireless Transmitter (MWT) Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure

More information

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position

More information

RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features: GE Measurement & Control Solutions RPS 8000 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in

More information

Monitores Equipos Móviles Especificaciones de Producto

Monitores Equipos Móviles Especificaciones de Producto EquipManager -4 F/-20 C to +140 F/+60 C (optional heater available for cold room applications) 0 100% noncondensing User-adjustable threshold 0.3G to 7G 10G (nondestructive)/100g (destructive) Piezoelectric

More information

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

Features. Picture. Specifications

Features. Picture. Specifications Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

DeltaV SISnet Repeater

DeltaV SISnet Repeater September 2013 Page 1 The DeltaV SIS platform is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety instrumented function. Fiber-optic

More information

The PACE5000 Modular Pressure Controller/Indicator

The PACE5000 Modular Pressure Controller/Indicator GE Sensing The PACE5000 Modular Pressure Controller/Indicator First in a new generation of modular, high precision Druck pressure controllers/indicators, designed for ATE and test bench applications. The

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

SureCross DX99 Intrinsically Safe (IS) FlexPower Node with Integrated Battery

SureCross DX99 Intrinsically Safe (IS) FlexPower Node with Integrated Battery DX80...B Models SureCross DX99 Intrinsically Safe (IS) FlexPower Node with Integrated Battery Configurable Node with an integrated battery and metal housing for 2 discrete inputs and 2 analog inputs The

More information

1701/22 FieldMonitor Management Interface Module

1701/22 FieldMonitor Management Interface Module 1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides

More information

Regards from the Team at Rheology Solutions.

Regards from the Team at Rheology Solutions. Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained

More information

Model 3051 Pressure Transmitter with HART Protocol

Model 3051 Pressure Transmitter with HART Protocol Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure

More information

Precision digital pressure gauge Model CPG1500

Precision digital pressure gauge Model CPG1500 Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration

More information

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring 3500/15 Power Supply Bently Nevada* Asset Condition Monitoring Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the

More information

3500/22M Transient Data Interface

3500/22M Transient Data Interface 3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Rosemount 751 Field Signal Indicator

Rosemount 751 Field Signal Indicator Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available

More information

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters Data Sheet Brooks Digital MFC's & MFM's Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters GENERAL FEATURES Wide FS flow range for measurement

More information

Cisco Aironet 1520 Series Lightweight Outdoor Access Points

Cisco Aironet 1520 Series Lightweight Outdoor Access Points . Data Sheet Cisco Aironet 1520 Series Lightweight Outdoor Access Points Outdoor Access Points Flexible, Secure Mesh Platform for Demanding Environments Self-configuring and self-healing mesh in response

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

S-series SQ Controller

S-series SQ Controller DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced

More information

3500/62 Process Variable Monitor

3500/62 Process Variable Monitor 3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit

More information

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 752 FOUNDATION fieldbus Remote Indicator Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional

More information

Technical Data Sheet. 3DLevelScanner

Technical Data Sheet. 3DLevelScanner Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

WIRELESS MAGNETIC CONTACT

WIRELESS MAGNETIC CONTACT WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

TEIP11 I/P signal converter for standard signals. Measurement made easy

TEIP11 I/P signal converter for standard signals. Measurement made easy Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy

More information

NI 9475 8-Channel, 60 V, High-Speed, Sourcing Digital Output Module

NI 9475 8-Channel, 60 V, High-Speed, Sourcing Digital Output Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9475 8-Channel, 60 V, High-Speed, Sourcing Digital Output Module Français Deutsch ni.com/manuals This document describes how to use the National Instruments

More information

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living 2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

NI USB-5681 RF Power Meter Specifications

NI USB-5681 RF Power Meter Specifications NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour

More information

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd. 16 channel wireless digital TC slate 1 Copyright BETSO ELECTRONICS Ltd. Contents 1. Product description...3 2. Top features...3 3. Control elements...4 4. Insertion of batteries / accumulators...6 5. External

More information

Bar code scanners CLV45x / CLV450 / Standard Density

Bar code scanners CLV45x / CLV450 / Standard Density ONLINE DATA SHEET www.mysick.com Bar code scanners CLV45x / CLV450 / Standard Density CLV450-0010 Bar code scanners CLV45x / CLV450 / Standard Density Model Name > CLV450-0010 Part No. > 1018556 At a glance

More information

Still Images or Video. Long Battery Life. Easy and Quick to Setup. How do they work?

Still Images or Video. Long Battery Life. Easy and Quick to Setup. How do they work? Motion Activated Still Images or Video View on Smartphone or PC Long Range Wireless Long Battery Life Free RF Transmission Invisible IR Flash at Night Easy and Quick to Setup Add up to 254 Cameras How

More information

1756 ControlLogix Chassis Specifications

1756 ControlLogix Chassis Specifications Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Wireless Data Logger Monitoring Systems

Wireless Data Logger Monitoring Systems Wireless Data Logger Monitoring Systems Table of Contents About MadgeTech, Inc. Wireless Systems & Components Wireless Data Loggers 2000A Wireless Data Logger Models MadgeTech Cloud Services MadgeTech

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Developer s Guide to Submetering Submetering Specifications for Multi-Housing Construction

Developer s Guide to Submetering Submetering Specifications for Multi-Housing Construction AmericanWater&EnergySavers 4431NorthDixieHighway BocaRaton,FL33431 TolFree:(800)90-908 Office:(61)361-4014 Fax:(61)361-4201 Developer s Guide to Submetering Submetering Specifications for Multi-Housing

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

3500/93 System Display

3500/93 System Display 3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide

More information

PACE1000 Precision Pressure Indicator

PACE1000 Precision Pressure Indicator GE Measurement & Control PACE1000 Precision Pressure Indicator A high precision Druck pressure indicator, designed for test bench, bench top and panel mount calibration, test and monitoring applications.

More information

1756 ControlLogix I/O Specifications

1756 ControlLogix I/O Specifications Technical Data 1756 ControlLogix I/O Specifications Catalog Numbers 1756 series Topic Page Additional Resources 1 Available 1756 I/O Modules 2 ControlLogix I/O Accessories 218 The ControlLogix architecture

More information

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89] Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

Lockout Specification BW Clip Maintenance-free single gas detector

Lockout Specification BW Clip Maintenance-free single gas detector Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than

More information

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet October 2014 Page 1 Redundant (WIOC) Fully redundant Wireless solution from to the Smart Wireless Field Link Optional simplex for smaller applications Seamless integration with DeltaV system and AMS Suite.

More information

ACTIVE RFID WHITE PAPER AMX

ACTIVE RFID WHITE PAPER AMX ACTIVE RFID WHITE PAPER AMX A c t i v e R F I D : T e c h n o l o g y W h i t e P a p e r Table of Contents Table of Contents 2 Overview: 3 Anterus RFID System Requirements: 4 Anterus RF: 7 Sizing 9 Acquisition

More information

2.0 System Description

2.0 System Description 2.0 System Description The wireless alarm system consists of two or more alarm units within a specified range of one another. Each alarm unit employs a radio transceiver, allowing it to communicate with

More information

PACE Modular Pressure Controller

PACE Modular Pressure Controller GE Measurement & Control Solutions PACE Modular Pressure Controller A new generation of high precision Druck pressure controller, designed for test bench, bench top & rack mount calibration & automated

More information

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter 3710 and 3720 Positioners Product Bulletin Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter Fisher 3710 pneumatic and 3720 electro-pneumatic positioners are designed for use with either

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Dimensions. LUC-M20 with F12 housing and process connection 2 approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions. Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning

More information

S-series Mass Connection Solutions

S-series Mass Connection Solutions DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination

More information

Fisher 4320 Wireless Position Monitor, with On/Off Control Option

Fisher 4320 Wireless Position Monitor, with On/Off Control Option Product Bulletin Fisher Wireless Position Monitor, with On/Off Control Option The Fisher eliminates the need for wiring to an on/off pneumatically actuated valve. It provides a precise wireless feedback

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

Cloud-based Wireless LAN for Enterprise, SMB, IT Service Providers and Carriers. Product Highlights. Relay2 Enterprise Access Point RA100 Datasheet

Cloud-based Wireless LAN for Enterprise, SMB, IT Service Providers and Carriers. Product Highlights. Relay2 Enterprise Access Point RA100 Datasheet Cloud-based Wireless LAN for Enterprise, SMB, IT Service Providers and Carriers The Relay2 Smart Access Point (RA100) is an enterprise-class access point designed for deployment in high-density environments

More information

WE70. FA Wireless LAN Unit. Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g

WE70. FA Wireless LAN Unit. Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g New Product News FA Wireless LAN Unit WE70 Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g Construct an Ideal Wireless LAN System for FA Applications! The FA Wireless

More information

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting Fast, accurate, mission-critical charging gives best starting reliability 4-rate, temperature-compensated

More information

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air

More information

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters

More information

PACE1001 Barometer Precision Barometric Indicator and Recorder

PACE1001 Barometer Precision Barometric Indicator and Recorder GE Measurement & Control PACE1001 Barometer Precision Barometric Indicator and Recorder A high precision Druck indicator and recorder, designed for barometric monitoring in laboratories, airfields and

More information

How To Make A Smart Transmitter

How To Make A Smart Transmitter For Differential/Gauge/Absolute/High Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy

More information

Datalogger DL/N 70 Version: 28.03.2012

Datalogger DL/N 70 Version: 28.03.2012 Datalogger DL/N 70 Version: 28.03.2012 Technical Specifications Pressure measuring range (mh20) 1... 5 > 5... 20 > 20... 250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar

More information

Technical Information RIA14

Technical Information RIA14 TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical

More information

Interference Analysis

Interference Analysis Application Note Interference Analysis JD7105A Base Station Analyzer / JD7106A RF Analyzer Introduction This document presents an overview of signal interference in RF wireless networks as well as a brief

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

RPS/DPS 8100. High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

RPS/DPS 8100. High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features: GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 40 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial,

More information

Agilent P940xA/C Solid State PIN Diode Switches

Agilent P940xA/C Solid State PIN Diode Switches Agilent P940xA/C Solid State PIN Diode Switches Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

Bar code scanners CLX49x / CLX490 / Standard Density

Bar code scanners CLX49x / CLX490 / Standard Density ONLINE DATA SHEET www.mysick.com Bar code scanners CLX49x / CLX490 / Standard Density CLX490-0010 Bar code scanners CLX49x / CLX490 / Standard Density Model Name > CLX490-0010 Part No. > 1019318 At a glance

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

1788 Linking Device Specifications

1788 Linking Device Specifications Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR

More information

QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living

QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living 2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use

More information

Compact Rugged Design. 300 Memory Channels. Single Head Remote Option. 6 Programmable Function Keys. Enhanced Kenwood Audio. 100W Transmit Power*

Compact Rugged Design. 300 Memory Channels. Single Head Remote Option. 6 Programmable Function Keys. Enhanced Kenwood Audio. 100W Transmit Power* HF TRANSCEIVER Compact Rugged Design 300 Memory Channels Single Head Remote Option 6 Programmable Function Keys Enhanced Kenwood Audio 100W Transmit Power* High-stability TCXO Enhanced Security Features

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

AN437. Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS. 1. Introduction. 2. Relevant Measurements to comply with FCC

AN437. Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS. 1. Introduction. 2. Relevant Measurements to comply with FCC Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS 1. Introduction This document provides measurement results and FCC compliance results for the Si4432B when operated from 902 928 MHz. The measurement

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications ZP110 on-line UPS 1, 2, 3, 6, 10kVA single/single phase LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs Emergency Devices (Lights/Alarms) Electro-Medical Devices

More information

S-series DeviceNet Interface Card

S-series DeviceNet Interface Card January 2013 Page 1 The DeltaV provides the solution for interfacing to discrete actuators and sensors. Offers freedom to choose appropriate bus for application Supports standard device-level busses Reduces

More information