TELENOR NETT SPECIFICATION

Similar documents
TELENOR NETT SPECIFICATION

Plug - Type (Male/Female) Attenuators CAA series Singlemode

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

How To Use The Visifault Visual Fault Locator

BLINK Triple-Play Connector

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Patch Cords for Data Center Applications

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

7.4 3M No Polish Connector

Why Expanded Beam types are essential in military and other harsh environment applications

Customer Interface Publication: CIP024

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

DIAMOND AVIM Connector

Optical Power Meter. Specification & User Manual

Newsletter NEWSLETTER JULY In this issue

ETD Fiber Optic Products

USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

Measuring of optical output and attenuation

Fiber Optic. Passive Components Edition 2009

TransPacket white paper. CWDM and DWDM networking. Increasing fibre-optical network utilization and saving on switches/routers

Guidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...

Connector Types. Fiberdk ApS Your Fiber Education Partner. Figure 1. Figure 2

Attaching the PA-A1-ATM Interface Cables

How To Properly Maintain A Fiber Optic Infrastructure

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

Cisco SFP Optics for Gigabit Ethernet Applications

POLARIZATION MAINTAINING FIBER PATCHCORDS AND CONNECTORS

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

Enabling 21 st Century Connectivity

Insertion Losses of Fiber Optical Connectors

3M Telecommunications Solutions for Networks. 3M Hot Melt Fibre Optic. Connectors, Kits and Accessories. Innovation

CABLE ASSEMBLIES BUILDING A PRODUCT

Data Center Design for 40/100G

Norway - In-Country Mobile Calling

VARIABLE FIBER OPTIC ATTENUATORS BLOCKING PIGTAIL STYLE

Guide to Patch Cords. and Pigtails.

POLARIZATION EXTINCTION RATIO METER

CISCO 10GBASE X2 MODULES

Compatibility of Bend Optimized Multimode Fibers White Paper. Issued September 2009

ST800K-U Optical Power Meter. User Manual V1.0

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

SUHNER FIBEROPTIC CONNECTOR FAMILY E-2000 TM

Fiber Solutions Short Form Catalog

Patch Cord Quality, Reliability and Performance. The Impact of Industry Specifications and Physical Parameters on Patch Cord Performance

DEFINING AND MEASURING PHYSICAL PARAMETERS OF PC POLISHED FIBER OPTIC CONNECTORS

Fibre optic hybrid broadcast camera systems

FIBER OPTIC ISOLATORS

APPLICATION NOTE POLARIZATION MEASUREMENTS

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

LASER TO FIBER SOURCE COUPLERS APPLICATION NOTES

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

HIGH POWER FIBER OPTIC PATCHCORDS

Kit Highlights and Key Features


Corning Cable Systems CAH Connections SM Gold Program Tested and Trusted Cable Assembly Houses for High-Quality Products

LASER TO FIBER COUPLER WITH ADJUSTABLE FOCUS USA PATENT #

3M Fiber Optic Polishing. Total. Solutions. for Your. Polishing Needs

Cable Assemblies. Corning Cable Systems

Reliable, Consistent, Quality

Cable Assemblies. Features and Benefits

Amplified High Speed Fiber Photodetectors

SECTION TESTING OF FIBER OPTIC CABLES

SC, FC and ST * Hot Melt Fiber Optic Connectors

Polymer Coated Fiber Cable (PCF)

Splicing and Fiber Assembly Compatibility for Non-Zero Dispersion-Shifted Fiber and Standard Single-Mode Fiber

Introduction to Optical Link Design

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

Fiber Optic Training Guide By Sarkis Abrahamian

PURE : REliable planning of data center cabling

ConnectorMax Analysis Software DELIVERING FAST PASS/FAIL ASSESSMENT OF CONNECTOR ENDFACES

Fiber Optics: Fiber Preparation and Fiber Connectors

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

INTERNATIONAL STANDARD

What testing is required for PREMISES Fiber Optic Cabling and the standards used

Fundamentals of Fiber Cable Management. White Paper

Security & Surveillance Cabling Systems

MEASUREMENT OF END FACE GEOMETRY ON FIBER OPTIC TERMINI...2

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

GISMA UNDERWATER CONNECTORS SERIES 40

Optical Fiber Switches

Qualifying Photonics for the Space Environment

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007


Transcription:

TELENOR NETT SPECIFICATION Specification no.: A61 Edition: 01 Date/approval: 000518/Jon Weberg Access to dark fibre. Specification of the network side of the user-network interface. Document ID Archive no. : : TNS/NI.AN-A61/000518-1 Index words : fibre, fibre optic, connector, adaptor(adapter), pigtails, patch-cords, passive optical component, Abstract : Specification for dark fiber included the fiber optic contact Telenor Nett AS P.O. Box 6701, St. Olavs plass N-0130 Oslo, Norway

Date: 000518 Edition: 01 Page: 2 of 5 Telephone: + 47 23 25 11 01, Fax: + 47 23 25 10 69 vigdis-helene.bergersen@telenor.com CONTENT 1 SCOPE... 3 2 REFERENCES... 3 2.1 NORMATIVE REFERENCES... 3 3 DEFINITIONS AND ABBREVIATIONS... 3 4 CONNECTOR FC/PC... 3 4.1 CONSTRUCTION... 3 4.2 PERFORMANCE... 4 5 FIBRE CABLE... 5 5.1 PERFORMANCE... 5

Date: 000518 Edition: 01 Page: 3 of 5 1 Scope This specification describes the connector and fibre cable and characteristics for the dark fibre provided by Telenor. In no event shall Telenor be liable to other parties for any direct, indirect, special, incidental, or consequential damages resulting from errors or defects in these specifications. 2 References 2.1 Normative references Ref.No. Specification Title Edition/ Issue [1] I-ETS 300 671 Transmission and Multiplexing ; Passive optical components; Fibre optical connectors for singlemode optical fibre communication systems; Common requirements and conformance testing. [2] CECC 86 115-803 Detail Specification: Connector sets of assessed quality for optical fibres and cables Type FC-PC tuned Nov. 1996 Nov. 1997 [3] ITU-T Recommendation G.652 Characteristics of a single-mode optical fibre cable April 1997 3 Definitions and abbreviations Patch-cord: Single-fibre cable with a connector in each end. The connectors in each end, can be of different type. Pig-tail: Single-fibre cable with a connector in one end. 4 Connector FC/PC 4.1 Construction The construction and size dimensions of the following connector sets are in accordance with:

Date: 000518 Edition: 01 Page: 4 of 5 TYPE Specification FC/PC: CECC 86 115-803 [2] The adaptors are in accordance with: TYPE Specification Clause /figure FC/PC CECC 86 115-803 [2] Figure 6 variant B 03 The ferrule endface shape and geometry after termination are in accordance with: TYPE Specification Clause /figure FC/PC CECC 86 115-803 [2] Figure 3 4.2 Performance The performance of the connector set, pigtail and patch-cord is in accordance with I-ETS 300 671 [1]. The performance will be according to one of the following clases: Class Attenuation grade Attenuation Return loss grade Return loss PT P Mean < 0,35 1) T > 35 db 3) PU P Mean < 0,35 1) U > 50 db 3) PV P Mean < 0,35 1) V > 55 db 3) QT Q Mean < 0,30 2) T > 35 db 3) QU Q Mean < 0,30 2) U > 50 db 3) QV Q Mean < 0,30 2) V > 55 db 4) 1) Mean < 0,35 1,0 db maximum for > 97 % of mating combinations 2) Mean < 0,30 0,60 db maximum for > 99 % of mating combinations 3) As measured when mated 4) As measured when mated and unmated Discrepancy Some connectors installed in the Telenor network before 1989 was of type FC and has not a PC polished endface. The performance of this type will typically be:

Date: 000518 Edition: 01 Page: 5 of 5 Attenuation Mean < 1 db Return loss > 12 db 5 Fibre cable 5.1 Performance Fibre cable and fibre performance parameters for transmission in the 1310 nm and the 1550 nm windows are given in ITU-T specification G-652 [3]. Note: For older cables installed before medio 1988 operation can only be guarantied in the 1310 nm window. Last page Telenor Nett AS P.O. Box 6701, St. Olavs plass N-0130 Oslo, Norway Telephone: + 47 23 25 11 01, Fax: + 47 23 25 10 69 vigdis-helene.bergersen@telenor.com