Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data
|
|
|
- Regina Holmes
- 10 years ago
- Views:
Transcription
1 Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data Copyright 2007, American Fibertek, Inc. 0411JD
2 Table of Contents Functional Description...3 Installation...3 RT-94845SL Components...4 RR-94845SL Components...5 Power Connections...6 Fiber Connections...6 Video Input / Output Connections...7 Ethernet Data Connections...7 RT-980 Series Status LED Indicators...8 RTX Status LED Indicators...9 RR-980 Series Status LED Indicators...10 RRX Status LED Indicators...11 Warranty / Service Information
3 INSTALLATION AND OPERATION INSTRUCTIONS INTRODUCTION Thank you for purchasing your American Fibertek Series 94845SL singlemode forty-eight channel video multiplexer with bi-directional Ethernet data. Please take a few minutes to read these installation instructions in order to obtain the maximum performance from this product. FUNCTIONAL DESCRIPTION The 94845SL Series units operate as a transmitter / receiver pair for the digital transmission of forty-eight simultaneous NTSC or PAL video signals along with one channel of bi-directional Ethernet data over one singlemode fiber optic cable. The Ethernet data channel will autoconfigure for a transmission speed of either 10 Mb/s or 100 Mb/s. An external switch is provided for selecting MDI (straight) or MDIX (crossover) Ethernet connections. The RT-94845SL transmitter accepts up to forty-eight video inputs in six groups containing eight videos and multiplexes each group into a high speed serial data stream. The first group s serial data stream modulates a laser at 1510nm wavelength. The second group s serial data stream modulates a laser at 1530nm wavelength. This pattern is repeated for group s three through six using wavelengths 1550nm through 1610nm respectively. A Course Wave Division Multiplexer (CWDM) combines these six wavelengths, along with the forward data wavelength of 1490nm and the return data wavelength of 1470nm, onto a single optical output port for connection to the fiber transmission system. Correspondingly, the RR-94845SL receiver converts the optical signal to forty-eight independent video output signals and one data output while transmitting the one return data channel. The 94845SL Series product is designed to operate over an optical loss budget range of 0dB to 21dB on 9um singlemode fiber. Refer to the product specification sheet for additional performance data. INSTALLATION THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES. 3
4 RT-94845SL COMPONENTS The RT-94845SL consists of the following components: 1) RT ) RT ) RTX ) SR-20 1) RT ) RT ) PCSC/UPC-0.3 1) PSR-2 1) RT ) RT ) MTX-CWDM-8 1) BPS-1 The individual 980 series video rack cards that make up the RT-94845SL are combined in a rack mount configuration using the SR-20 subrack. Please refer to the instruction manuals for the SR-20 and the PSR-2 for information on the installation of the subrack with its power supply. The individual 980 series rack cards can slide into any of the open slots in the SR-20 subrack, however, the recommended configuration is shown below. This configuration starts with a blank panel next to the PSR-2 power supply followed by the RTX data card. The lowest wavelength video card, the RT continues the configuration which ends with the highest wavelength card, the RT , at the left side of the rack. Following this configuration allows the fiber port on the back of the 980 series card to best line up with its associated port on the CDWM unit. Use a small screwdriver to push and lock the ¼ turn fasteners into place. The Multi-Channel Digital Video CWDM that optically multiplexes the six video rack cards and one data rack card used in the RT-94845SL is labeled MTX-CWDM-8. It should be mounted directly below its corresponding SR-20 subrack with a ½ RU space between the two components. To maximize the performance and life of the system, installing a fan above the SR-20 subrack is recommended to pull air up across the RT-94845SL components. RT-94845SL 4
5 RR-94845SL COMPONENTS The RR-94845SL consists of the following components: 1) RR ) RR ) RRX ) SR-20 1) RR ) RR ) PCSC/UPC-0.3 1) PSR-2 1) RR ) RR ) MRX-CWDM-8 1) BPS-1 The 980 series video rack cards and the data rack card that make up the RR-94845SL are installed in a manner similar to the RT-94845SL (see drawing below). The Multi-Channel Digital Video CWDM that optically demultiplexes the six video rack cards and the one data card used in the RR-94845SL is labeled MRX-CWDM-8. Mounting procedures and recommendations should follow those used for the RT-94845SL. RR-94845SL POWER SOURCE Power to the 980 series and 45 series rack cards is supplied by the subrack. Please refer to the SR-20 and PSR-2 instructions for further details. The CDWM unit is a passive device which does not require any power source. POWER CONNECTION Power is supplied to the individual 980 series and 45 series units via a four finger backplane connector. The individual components can be inserted into the subrack or removed from the subrack with power applied to the backplane. Please refer to the SR-20 and PSR-2 instructions for details. The CDWM unit is a passive device which does not require any power connection. 5
6 RT-94845SL FIBER CONNECTIONS The fiber optic connection to the user s infrastructure is made via a SC connector located at the back of the CDWM unit next to the power input. Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used. SC patchcords are supplied for the intra-fiber connections between the CWDM and each of the 980 series and 45 series units. The wavelength listed for each port on the CWDM must correlate with the wavelength listed on the 980 series unit to which that port is attached. The top port of the RTX connects to the 1470nm port on the CWDM. The bottom port of the RTX connects to the 1490nm port on the CWDM. Follow the drawing below for the proper connections of the fiber patchcords. RT-94845SL RR-94845SL FIBER CONNECTIONS The fiber optic connections on the RR-94845SL are similar to those for the RT-94845SL with the exception of the RRX data card. On the RRX , the bottom port connects to the 1470nm port on the CWDM. The top port of the RRX connects to the 1490nm port on the CWDM. Follow the drawing on the next page for the proper connections of the fiber patchcords. 6
7 RR-94845SL VIDEO INPUT / OUTPUT CONNECTIONS Video input and output connections are located on the rear of the 980 series units. A BNC connector is provided for each channel. The video inputs are connected to an appropriate 75Ω baseband video source such as a camera or a video recorder output. The 75Ω video outputs can be looped through typical baseband video inputs of switchers, recorders and other equipment as required. For proper operation, the outputs must be terminated with 75Ω. For optimum performance the video cables should be the shortest length of coax practical. The location of a video input to the RT-94845SL will be mirrored as a video output at the RR SL. For example, the Channel 2 video input on the RT will become the Channel 2 video output on the RR after traveling across the fiber infrastructure. ETHERNET DATA INPUT / OUTPUT CONNECTIONS A RJ45 connector is used to connect UTP Ethernet data to the 45 series units. MDI / MDIX Switch All Ethernet equipment is designed with a MDI interface port or a MDIX interface port. The terms MDI and MDIX refer to a specific orientation of the transmit data signal and the receive data signal on the RJ45 connection to the unit. Some units have a switch built into them that allows you to choose the port to be either MDI or MDIX. Other units can auto-configure to either speed. Typically, a computer or terminal is wired as an MDI port connection and a network hub or switch is wired as an MDIX connection. The MDI configured device is connected to the MDIX device with a straight through Ethernet patch cable. Whenever a connection from one MDI device to another MDI device is required, the use of a crossover cable is required to reorient the signals, making the first device appear as if it was configured as MDIX. The RTX and RRX are shipped in the MDI configuration. Therefore, when connecting to a MDI configured device a crossover cable should be used. In the event the proper cable is not available, an external switch is provided at the rear of the 45 series unit for reconfiguring the unit as a MDIX port. If the 45 series unit is connected to an auto-configure device, it is not necessary to change the MDI / MDIX switch. 7
8 RT-980 SERIES STATUS INDICATORS Each of the RT-980 series transmitters provides the following front panel LED status indicators to aid in installation and troubleshooting: VIDEO 1 THROUGH VIDEO 8 A bi-color LED indicator is provided for the each of the eight video inputs to the RT-980 series transmitters. Video status associated with each of these LED s is summarized below. Video Presence LED Red Video Status Proper Input Video Present Input Video Not Detected 8
9 RTX STATUS INDICATORS The RTX transceiver provides the following LED status indicators to aid in troubleshooting: UTP ACTIVITY A green LED indicator monitors the presence of any data signals into the RTX from the twisted pair wires. Input status associated with this LED is summarized below. UTP Activity Indicator Ethernet Data Status Data Packets Present UTP LINK A bi-color LED indicator monitors the speed of any data signals present through the RTX Data status associated with this LED is summarized below. UTP Link Indicator Amber Ethernet Data Status / Speed 100 Mb/s Full or Half Duplex 10 Mb/s Full or Half Duplex POWER A green LED indicator monitors the presence of DC voltage into the RTX from the subrack. DC voltage status associated with this LED is summarized below. Power Indicator DC Input Voltage Status DC Voltage Present Check Subrack Power Supply FIBER ACTIVITY A green LED indicator monitors the presence of any data signals into the RTX from the fiber cable. Input status associated with this LED is summarized below. Fiber Activity Indicator Ethernet Data Status Data Packets Present FIBER LINK A bi-color LED indicator monitors the speed of any data signals present through the RTX Data status associated with this LED is summarized below. Fiber Link Indicator Amber Ethernet Data Status / Speed 100 Mb/s Full or Half Duplex 10 Mb/s Full or Half Duplex 9
10 RR-980 SERIES STATUS INDICATORS Each of the RR-980 series receivers provides the following front panel LED status indicators to aid in installation and troubleshooting: VIDEO 1 THROUGH VIDEO 8 A bi-color LED indicator is provided for the each of the eight video outputs from the RR-980 series receivers. Video status associated with each of these LED s is summarized below. Video Presence LED Red Video Status Proper Output Video Present Output Video Not Detected OLI A bi-color LED indicator monitors the power of the optical input signal that is being received at the RR-980 series unit from video channels one through eight of its corresponding RT-980 series unit. AC power and optical input status associated with this LED are summarized below. Optical Level Indicator AC Power Status Optical Status On Proper Optical Input Power Present Red On Optical Input Not Detected Check Power Supply Input SYNC A bi-color LED indicator is provided to monitor the proper serialization of the electrical video data stream through the RR-980 series unit. Each group of eight videos has its own SYNC indicator. Sync status associated with this LED is summarized below. Sync LED Red Sync Status Proper Data Stream Serialization Present Data Stream Serialization Not Detected 10
11 RRX STATUS INDICATORS The RRX transceiver provides the following LED status indicators to aid in troubleshooting: UTP ACTIVITY A green LED indicator monitors the presence of any data signals into the RRX from the twisted pair wires. Input status associated with this LED is summarized below. UTP Activity Indicator Ethernet Data Status Data Packets Present UTP LINK A bi-color LED indicator monitors the speed of any data signals present through the RRX Data status associated with this LED is summarized below. UTP Link Indicator Amber Ethernet Data Status / Speed 100 Mb/s Full or Half Duplex 10 Mb/s Full or Half Duplex POWER A green LED indicator monitors the presence of DC voltage into the RRX from the subrack. DC voltage status associated with this LED is summarized below. Power Indicator DC Input Voltage Status DC Voltage Present Check Subrack Power Supply FIBER ACTIVITY A green LED indicator monitors the presence of any data signals into the RRX from the fiber cable. Input status associated with this LED is summarized below. Fiber Activity Indicator Ethernet Data Status Data Packets Present FIBER LINK A bi-color LED indicator monitors the speed of any data signals present through the RRX Data status associated with this LED is summarized below. Fiber Link Indicator Amber Ethernet Data Status / Speed 100 Mb/s Full or Half Duplex 10 Mb/s Full or Half Duplex 11
12 LIFETIME WARRANTY INFORMATION American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of defects in materials and workmanship. Defective products will be repaired or replaced at the exclusive option of American Fibertek. A Return Material Authorization (RMA) number is required to send the products back in case of return. All returns must be shipped prepaid. This warranty is void if the products have been tampered with. This warranty shall be construed in accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction over this contract. EXCEPT FOR THE FOREGOING WARRANTY, THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT. In any event, American Fibertek will not be responsible or liable for contingent, consequential, or incidental damages. No agreement or understanding, expressed or implied, except as set forth in this warranty, will be binding upon American Fibertek unless in writing, signed by a duly authorized officer of American Fibertek. SERVICE INFORMATION There are no user serviceable parts inside the unit. In the event that service is required to this unit, please direct all inquiries to: American Fibertek, Inc. Phone: (877) Belmont Drive Phone: (732) Somerset, NJ FAX (732) [email protected] 12
USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A
USER S MANUAL Ethernet 10/100 Transceiver Series DL221/DL221A June 1999 ETHERNET 10/100 TRANSCEIVER INSTRUCTION MANUAL SERIES DL221/DL221A INTRODUCTION Thank you for purchasing the Radiant Communications
16-Port and 24-Port 10/100 Switches
16-Port and 24-Port 10/100 Switches Use this guide to install the following products: SR216 SR224 16-Port 10/100 Switch 24-Port 10/100 Switch User Guide COPYRIGHT & TRADEMARKS Specifications are subject
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports (800-0037) Doc. PUBTPASXSFPU Rev., 07/08 Contents Introduction.... Key Features... Unpacking and Inspection....3 Product
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU. 800-0045-001 Doc. PUBTPACUU Rev. 1, 12/08. In-Line
Installation Guide for 10/100 to Triple-speed Port Aggregator Model TPA-CU In-Line 800-0045-001 Doc. PUBTPACUU Rev. 1, 12/08 Contents Introduction.....................................................
FriendlyNET FX4000 4-Slot Modular Switch. User s Manual
FriendlyNET FX4000 4-Slot Modular Switch User s Manual 2 Asanté FriendlyNET FX4000 Table of Contents Chapter 1. Introduction 5 Key Features 5 Package Contents 5 Chapter 2. Product Overview 7 Front Panel
Gigabit Ethernet Copper-to-Fiber Converters
Gigabit Ethernet Copper-to-Fiber Converters GFT-10XX Standard multi-mode & single-mode 1000BASE-T GFT-1055E Extended Reach Multi-Mode over standard fiber GFT-1037A/B Single-Fiber, Bi-Directional Single-Mode
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)
USER MANUAL MODEL 2300M SERIES OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M) An ISO-9001 Certified Company Part# 07M2300M Doc# 077321U Rev. A Revised 4/14/03 SALES OFFICE (301) 975-1000
Gigabit Switching Ethernet Media Converters - Product User Guide
Gigabit Switching Ethernet Media Converters - Product User Guide PL0338 Issue3 Introduction These Tyco Electronics Gigabit Media Converters translate between 1000Base-T copper and 1000Base-X fiber optic
M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide
M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual
FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual Asanté Technologies, Inc. 821 Fox Lane San Jose, CA 95131 Copyright Notice Copyright 1997 by Asanté Technologies, Inc. All rights reserved. No
Cisco CWDM GBIC and CWDM SFP Installation Note
Cisco CWDM GBIC and CWDM SFP Installation Note, Product Numbers: CWDM-GBIC-1470= CWDM-GBIC-1550= CWDM-SFP-1470= CWDM-SFP-1550= CWDM-GBIC-1490= CWDM-GBIC-1570= CWDM-SFP-1490= CWDM-SFP-1570= CWDM-GBIC-1510=
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL
OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: [email protected] www.olsontech.com
FlexPoint T1/E1 Copper to Fiber Line Driver
BLACK BOX NETWORK SERVICES MT660A-MM MT661A-SM MT660A-MM-E MT661A-SM-E FlexPoint T1/E1 Copper to Fiber Line Driver CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX SUPPORT (outside U.S. call 724-746-5500)
Connector and Cable Specifications
APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page
Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap
Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap 800-0150-001 Rev. F PUBTPCU3ZDU 8/10 Gig Zero Delay Tap PLEASE READ THESE LEGAL NOTICES CAREFULLY. By using a Net Optics Tap you agree
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
2-Pair HDSL1 Adtran Fiber Optic Link System
ISSUE 2 June 01, 2004 Data Sheet #37 2-Pair HDSL1 Adtran Fiber Optic Link System Contents 1. General. 1 2. Application... 2 3. Housings.. 2 4. Installation 3 5. Provisioning. 5 6. LED Indicators. 6 7.
8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual
IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400 User s Manual - 1 - Trademarks Disclaimer Copyright PLANET Technology Corp. 2006. Contents subject to revision without prior notice. PLANET
Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB
Kramer Electronics, Ltd. USER MANUAL Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 2 4 Your Kramer
MICROSENS Media Converter 10/100/1000T to Gigabit Fiber
MICROSENS Media Converter 10/100/1000T to Gigabit Fiber User Guide 10/100/100 TX to Gigabit Fiber Media Converter Page 2/7 Package Contents Please refer to the package content list below to verify them
Boca s Family of Ethernet Products
1 Boca s Family of Ethernet Products BOCAHUB-16 Plus TM Installation Guide PRODUCT CODE: BEN220 2 BOCAHUB-16Plus Boca s Family of Ethernet Products 3 BOCAHUB-16 Plus 4 Boca s Family of Ethernet Products
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
HP ProCurve High-Speed Transceivers Installation Guide
HP ProCurve High-Speed Transceivers Installation Guide Introduction The HP ProCurve High-Speed Transceivers can be installed into a number of HP ProCurve networking devices to provide 100 Mbps and 1000
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
OPT-700 - SERIAL TO FIBER OPTIC CONVERTER
USER S MANUAL OPT-700 - SERIAL TO FIBER OPTIC CONVERTER JUL / 05 OPT-700 VERSION 1 TM FOUNDATION OPT700ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date
ECR Shelf System Installation Guide Centralized Rack Mount Call Recording
Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: [email protected] [email protected] www.algosolutions.com
c o m m u n i c a t i o n n e t w o r k s
c o m m u n i c a t i o n n e t w o r k s Founded in 2007, by George Lichtblau Former founder and owner of IFS. Majority of ComNet employees came from IFS. Massive industry experience. Same faces. New
16-Port and 24-Port 10/100/1000 Gigabit Switches
16-Port and 24-Port 10/100/1000 Gigabit Switches Use this guide to install the following products: SR2016 16-Port 10/100/1000 Gigabit Switch SR2024 24-Port 10/100/1000 Gigabit Switch User Guide COPYRIGHT
Installation Guide for GigaBit Fiber Media Converter
Installation Guide for GigaBit Fiber Media Converter Doc. PUBCVSX/GCUU Rev.1, 06/06 Contents Introduction..................................................... 1 Key Features.....................................................
NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT
Main Power Connections NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT Camlok style "J" series connectors are for connection of up to a 300 Amp 120/240 VAC or 120/208 VAC electrical service. These connections
USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)
USER MANUAL MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun) An ISO-9001 Certified Company Part #07M460-E Doc. #019021UE Revised 02/23/00 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)
Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide
Copper to Fiber Stand-Alone Media Converter Quick Installation Guide Model No. FVT-2001 FVT-2002 FVT-2201 FVT-2401 GVT-2000 GVT-2001 Description 10/100BASE-TX to 100BASE-FX MMF SC Converter, 2km 10/100BASE-TX
User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter
User Guide MC100CM MC110CS Fast Ethernet Media Converter MC111CS MC112CS WDM Fast Ethernet Media Converter COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark
Installation Guide for. 10/100BaseT Port Aggregator Tap with Active Response. Models PA-CU-AR, PAD-CU-AR. Doc. PUBPACUARU Rev.
Installation Guide for /0BaseT Port Aggregator Tap with Active Response Models PA-CU-AR, PAD-CU-AR Doc. PUBPACUARU Rev. 1, 06/06 /0 Port Aggregator Tap Contents Introduction.....................................................
Cisco TelePresence VCR MSE 8220
Cisco TelePresence VCR MSE 8220 Getting started 61-0008-05 Contents General information... 3 About the Cisco TelePresence VCR MSE 8220... 3 Port and LED location... 3 LED behavior... 4 Installing the VCR
HARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
INTRODUCTION TO MEDIA CONVERSION
WHITE PAPER INTRODUCTION TO MEDIA CONVERSION Table of Contents Introduction 1 What is a Media Converter? 1 Advantages of Media Conversion Technology 1 Benefits of Fiber Optic Cabling 2 Types of Media Converters
Perle 10/100/1000 Ethernet Media Converter Module
Perle 10/100/1000 Ethernet Media Converter Module Installation Guide C-1110-XXXXX CM-1110-XXXXX C-1110-SFP CM-1110-SFP Unmanaged Module Managed Module Unmanaged Module Managed Module P/N 5500308-21 Overview
CISCO WDM SERIES OF CWDM PASSIVE DEVICES
DATA SHEET CISCO WDM SERIES OF CWDM PASSIVE DEVICES Cisco Systems introduces its second generation of coarse wavelength-division multiplexing (CWDM) passive devices boasting increased functions and improved
TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use
Standard Shipping Contents of the TW-SSBP-007: 1 qty Site Survey Battery Pack (Diagram 1) 1 qty Charger (Diagram 2) 1 qty RJ-45 Red (802.3af) POE Cable (Diagram 3) 1 qty 2 56 Volt Power Cord (Diagram 4)
INSTRUCTION MANUAL 2044-01 T1 TO RS422 INTERFACE
INSTRUCTION MANUAL 044-0 T TO RS4 INTERFACE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., and may not be reproduced or duplicated in any form without
Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600
Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission
Compact SDI Routers KUMO 1604 KUMO 1616 KUMO CP
Compact SDI Routers 1616 KUMO 1604 KUMO 1616 KUMO CP KUMO Compact SDI Routers Compact SDI Routers NEW 1616 Rear Panel 1604 Rear Panel KUMO compact SDI routers are small and cost-effective, yet robust and
HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide
HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP Part Number: 574412-doc Published: May 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein
Optical Power Meter. Specification & User Manual
Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4
Single Port Gigabit Ethernet Media Converter Board (P/N 201350-xxx) User s Manual And Troubleshooting Guide
Single Port Gigabit Ethernet Media Converter Board (P/N 201350-xxx) User s Manual And Troubleshooting Guide August 12, 2009 Rev C Moog Components Group Springfield Operations 750 West Sproul Road Springfield,
USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company
USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0
MS900AC-B-LS User Information
MS900AC-B-LS User Information MS900-R-AC-B-LS systems equipped with MR900 Micro Receiver are Receive-Only. MS900-X-AC-B-LS systems equipped with MX900 Micro Transceiver will Send and Receive. The model
2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.
2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL DTronics Inc. 40 State Highway 94, Suite L2A McAfee, NJ 07428 201-362-1606 Fax: 781-207-0351 UNPACKING Each DVI Link DVI Switch package includes
User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams
Research Isometric Transducer 0 to 5 grams and 0 to 50 grams User's Manual Research Isometric Transducer 0 to 5 g and 0 to 50 g, 110 VAC/60 Hz MA1 72-4481 Research Isometric Transducer 0 to 5 g and 0 to
T-Extender E-Extender
T-Extender E-Extender TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8
CriticalConneX. 100/1000 CriticalTAP User Guide
Network Critical CriticalConneX 100/1000 CriticalTAP User Guide CC1220, CC1225 & CC1230: CriticalConneX TAP Module CC1220-P, CC1225-P & CC1230-P: CriticalConneX Portable TAP Rev D - August 2007. Copyright
How To Install A Power Supply (Uplast) With A Battery Pack
APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects
8-Port HDMI Switch USER MANUAL VS0801H
8-Port HDMI Switch USER MANUAL VS0801H FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
LevelOne User Manual VDS-0120 Ethernet over VDSL2 Converter (PSE)
LevelOne User Manual VDS-0120 Ethernet over VDSL2 Converter (PSE) V1.0 1 Table of Content 1. Introductions... 3 2. Application Notes... 3 3. Features... 4 4. Packing Contents... 4 5. LED Indicators...
USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.
The leader in rugged fiber optic technology. USER GUIDE! Lifetime Warranty U-04 015A-01 Channel POTS Mux DIN Fiber Link System SYSTEM INSTALLATION INFORMATION Introduction The Channel POTS Mux DIN Fiber
DDP-3 Engineering Guide
Issue, May 998 DDP- Engineering Guide Content Page INTRODUCTION... Revision History... List of Changes... Trademark Information... Related Publications... Admonishments.... GERAL... A. Overview of the
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.
Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver. OWNER'S MANUAL VR36A XC18A XM13A MODEL VK69A (INCLUDES XC18A CAMERA, XM13A
Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports
Installation Guide for Gigait Fiber Port ggregator Tap with SFP Monitor Ports Doc. PUPDSXSFPU Rev., 08/06 Gigait Fiber Port ggregator Tap Contents Introduction.....................................................
Operation Manual SmartView Duo. Mac OS X Windows
Operation Manual SmartView Duo Mac OS X Windows May 2011 Contents SmartView Duo Operation Manual 4 How to Install 22 Helpful Information SmartView Duo product diagram 5 Pre-installation overview and planning
Product Information D23m Digital I/O System
Product Information D23m Digital I/O System 1-11 Contents 1 SUMMARY PRODUCT DESCRIPTION... 3 2 OVERVIEW... 4 3 SYNC/CLOCKING... 5 4 ETHERNET AND CONTROL... 5 5 POWER AND STATUS... 6 5.1 POWER SUPPLY AND
Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks
Fiber s Role in the Video Security & Surveillance Network Curt Carlson Product Manager Transition Networks Video technology overview Typical video network architecture Limitations of copper-based cabling
Using a Fabric Extender with a Cisco Nexus 5000 Series Switch
CHAPTER Using a Fabric Extender with a Cisco Nexus 5000 Series Switch This chapter describes the Cisco Nexus 000 Series Fabric Extenders (FEXs) and includes these sections: Information About, page - Cisco
Fibre Channel Fiber-to-Fiber Media Converters
Fibre Channel Fiber-to-Fiber Media Converters CM-155-XX CM-131-XX Multi-mode to Single-mode series Single-mode to Single-mode series Low cost CCM-1600 Fibre Channel media converter modules by Canary Communications
T1 Backhaul Connectivity Solution All Products :: Application Note
Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments
ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide
31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM
Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed
8-Port 10/100M N-Way Mini Switch
1 8-Port 10/100M N-Way Mini Switch User Guide Introduction 2 This user guide is applied to the 8 ports 10/100M N-Way Mini Switch. The 8-Port 10/100M N-Way Mini Switch is designed for easy installation
Optimux-34, Optimux-25
Data Sheet Optimux-34, Optimux-25 Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber optic uplink E3 copper uplink for Optimux-34 Single-mode, multimode, single-mode over
MDI/MDIX) FEP-32008T-3
TM Mico-Switch/8 8 Port 10/100Base-TX Switch (Auto MDI/MDIX) FEP-32008T-3 U SER S M ANUAL (Auto MDI/MDIX) FEP-32008T-3 TM TM Package Contents Package contents include the following: Micro-Switch/8; 8 Port
Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features
Description The Light Link Series 2 optical transmitter model employs a high performance thermally stabilised, DFB, low-chirp, isolated laser to transmit CATV signals. Operating on a specific optical wavelength
SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C37.94. Fiber Service Units
SOLUTIONS FOR AN EVOLVING WORLD T1/E1 and C37.94 Fiber Service Units T1/E1 & C37.94 1 April 2013 Your world is changing and so are we. At RFL, we know your needs change much faster than your infrastructure.
HARTING econ 3000 Introduction and features
HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications
Migration Strategy for 40G and 100G Ethernet over Multimode Fiber
Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year
Ethernet over VDSL2 PoE PD Converter
Ethernet over VDSL2 PoE PD Converter UVE7312-MSPD User Manual Ver 1.02 Copyright EUSSO Technologies, Inc. All rights reserve 1 Table of Content 1. Introductions... 2 2. Application Notes... 2 3. Features...
Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8
Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,
T855 Day & Night Security Camera
T855 Day & Night Security Camera For use with Swann 4500 DVR EN INSTRUCTION MANUAL MT855_091014E Swann 2014 Before you begin Introduction Congratulations on your purchase of this T850 Day & Night Security
Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications
Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output
10/100/1000 Base-T to Gigabit Fiber Media Converter
10/100/1000 Base-T to Gigabit Fiber Media Converter Operation Manual DA-MC1101 Powered by Before Using the Product FCC Compliance Statement This device complies with part 15 of the FCC Rules. Operation
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Perle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
NXU RoIP Link to Eliminate Voice-Grade Leased Line
NXU RoIP Link to Eliminate Voice-Grade Leased Line Purpose This Application Note will describe a method at which Network Extension Units (NXUs) can be utilized on an existing digital network to eliminate
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch
Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch CMX-2400G SNMP/Web Manageable, Modular Switch chassis with two GBIC slots Features: Modules with eight 10/100 UTP or LC Fiber ports: CMX-8TX,
Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches
ComNet Fiber Optic and Ethernet Transmission Equipment is setting the standard for value and performance. ComNet is a major provider of video, audio and data transmission, and network communication solutions
Prisma IP 10 GbE VOD Line Card
Digital Transport Prisma IP 10 GbE VOD Line Card Description The Prisma IP 10 GbE Line Card family of products consists of Transmitter (OTX), Receiver (ORX), and Transceiver (OTR) modules. These modules
DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
Terayon DOCSIS Modem Installation. Guide
Terayon DOCSIS Modem Installation Model: TJ 700 Series Modem Guide Power Cable PC Data Test 4988 Great America Parkway Santa Clara, CA 95054 www.terayon.com 8500229 Rev A Table of Contents Table of Contents
TTL to RS232 Adapter User Guide
TTL to RS232 Adapter User Guide Revision D March 28, 2011 Document Part Number GC-800-313d Copyright and Trademark Copyright 2006-2011, Grid Connect, Inc. All rights reserved. No part of this manual may
Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3
Data Sheet Optimux-45, Optimux-45L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Any Traffic over Fiber Combination of T1 and E1 channels Transmission over coax or fiber optic
Dome Security Camera with IR night vision
Dome Security Camera with IR night vision EN INSTRUCTION MANUAL 1 Before you begin Limited Warranty Terms & Conditions Swann Communications warrants this product against defects in workmanship and material
Attaching the PA-A1-ATM Interface Cables
CHAPTER 4 Attaching the PA-A1-ATM Interface Cables To continue your PA-A1-ATM port adapter installation, you must attach the port adapter cables. The instructions that follow apply to all supported platforms.