Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators



Similar documents
Improve competiveness of IDC and enterprise data centers with DCIM

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Top-Level Energy and Environmental Dashboard for Data Center Monitoring

Re Engineering to a "Green" Data Center, with Measurable ROI

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Managing Data Centre Heat Issues

How To Improve Energy Efficiency In A Data Center

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Selecting Rack-Mount Power Distribution Units For High-Efficiency Data Centers

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Benefits of. Air Flow Management. Data Center

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Harmonizing Global Metrics for Data Center Energy Efficiency

Data Centre Infrastructure Assessment

Data Center Infrastructure Management: ERP for the Data Center Manager

One unbelievable solution for rack-level data center power management. Sentry Power Manager. Solutions for the Data Center Equipment Cabinet

Reducing the Annual Cost of a Telecommunications Data Center

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

DataCenter 2020: first results for energy-optimization at existing data centers

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Green Data Centre Design

Power Distribution Units (PDUs): Power monitoring and environmental monitoring to improve uptime and capacity planning

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Data Center Technology: Physical Infrastructure

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Environmental Data Center Management and Monitoring

5 Reasons. Environment Sensors are used in all Modern Data Centers

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Specialty Environment Design Mission Critical Facilities

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

EO and Smart Federal Government Data Center Management

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

How green is your data center?

Data Center Power Distribution at the Cabinet Level: The top 12 questions you need to ask to improve data center energy effciency

Datacenter Efficiency

Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions Sponsored by:

How to Build a Data Centre Cooling Budget. Ian Cathcart

DOE Data Center Air-Management (AM) Tool: Data Collection Guide. Version 1.18 (November 24, 2014)

Design Best Practices for Data Centers

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Metrics for Data Centre Efficiency

Energy Management Services

Server Technology, Inc.

GREEN DATA CENTER DESIGN

An Introduction to Cold Aisle Containment Systems in the Data Centre

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Energy Efficiency and Effective Equipment Cooling In Data Centers. Presentation at ASHRAE Summer Meeting Quebec City, Canada, June 27, 2006

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers

Sealing Gaps Under IT Racks: CFD Analysis Reveals Significant Savings Potential

Recommendation For Incorporating Data Center Specific Sustainability Best Practices into EO13514 Implementation

Data Center Lifecycle and Energy Efficiency

Introduction to Hitachi Group Environment- conscious Data Center Programme for inspiring change

Data center lifecycle and energy efficiency

Reducing Data Center Energy Consumption

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Measure Server delta- T using AUDIT- BUDDY

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

THE GREEN DATA CENTER

ICT and the Green Data Centre

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

1. Data Centre Environment Why focus on Data Centres? Hitachi Eco-Friendly Data Centre Solutions

Data Centre Infrastructure Management DCIM. Where it fits with what s going on

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Data Centre Testing and Commissioning

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Premium Data Centre Europe Pricing, Business Model & Services

The Mission Critical Data Center Understand Complexity Improve Performance

How To Benchmark Power Production

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

Green IT Promotion Council, Japan

Center Thermal Management Can Live Together

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Legacy Data Centres Upgrading the cooling capabilities What are the options?

CenterMind P+ Intelligent Power Management for your Data Center

DATA CENTER PHYSICAL INFRASTRUCTURE

DataCenter Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Airflow and Cooling Performance of Data Centers: Two Performance Metrics

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Transcription:

Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators Awareness of environmental protection issues, has many industry types focusing and pursuing energy saving and carbon reduction. New green industry standards and verifications are gaining acceptance including green IT, data center, products and energy management systems, and ISO50001. Everything green is bringing a wave of green opportunities. A ranking report on domestic energy users' energy usage index (EUI) indicates that the top three energy users are telecomm data centers, network data centers, and telecomm carriers. Their average annual unit area power consumption doubles that of a department store, the number four power user. It is clear that an information data center consumes a large amount of power per floor space and with rising cloud applications, green data centers' requirements are expected to grow as well. Recent surveys show that IT/telecomm relevant carbon emissions have topped the global sources of GHG emissions rankings. Emissions are currently at 860 million tons per year, rapid growth is expected along with rising global demands for computing, data storage and telecomm technologies. Despite heavy investments in designing better data centers, improving equipment and data center energy efficiency,

it is estimated that global IT related carbon emission may rise to 1.54 billion tons by 2020. This shifts more and more attention toward the construction of green data centers. Aiming at optimizing equipment energy efficiency within data centers, ATEN has developed a green data center equipment and energy performance benchmarking system to improve performance on power usage. Combining a dynamic rack cooling index (RCI) and return temperature index (RTI) with its energy saving sensor, eco-pdu devices, the system's eco-sensor software provides energy usage data accessing, diagnosis and forecasting tools to optimize energy usage, based on the system's recommendations, without dampening the reliability of the IT equipment. A data center's IT equipment and infrastructure consume the lion's share of energy. In general, only one-third of electricity used by a typical data center goes to IT equipment, with the remaining two-thirds going to infrastructure. Reducing infrastructure power requirements, improving energy usage efficiency, and improving cooling efficiency of HVAC system has become the key of large scale data center construction projects. A data center's greening and energy saving process is a long term and continuous process that require a multi-dimensional approach instead of piecemeal equipment considerations. The first step is to identify the ingredients of a data center's infrastructure power consumption, power usage status and potential of power usage cut to shape a comprehensive solution. A strategy aimed at a single layer and isolated problem does not work. Suppliers who have skills in limited tiers gain little results in data center's green and energy saving markets. Better data center energy saving comes from improved energy usage efficiency. That is, to apply every watt of power to its maximum benefit. You have to manage a data center's power consumption before you can talk about power efficiency. This, in turn, means to take good power consumption measurements, as you cannot manage anything without it being measured and quantified. The very first job in improving a data center's power efficiency is to take accurate measurements of the power consumed. The intelligent rack PDU (IRP) is by far the most accurate tool in measuring power consumed by information equipment. Located within individual cabinets, the rack PDU is the last device distributing power to information equipment, and so is the best

point for taking their power consumption measurements let alone the remote on/off and ambient parameter measurement function possessed by some high end IRPs. By working together with the most advanced software eco-sensors, ATEN's eco-pdu ensures the green data center's environment and energy performance benchmark system come true. The free-of-charge eco-sensors are critical to your energy saving goal and improve ATEN products' competitiveness. The basic features are: 1. Graphical display of racks in data center for easy control by data center administrator - Fundamental data center monitoring: Comprehensive monitoring display

2. Instant data display to enable data center administrators' direct control at their office or control center Fundamental data center instant monitoring: Instant power status (KW) 3. Historical data analysis Fundamental data center electricity monitoring: Historical power usage report (KW)

4. Ambient situation and benchmarking analysis Fundamental data center instant monitoring: Rack Cooling Index (RCI) Rack Cooling Index (RCI) and Return Temperature Index (RTI) measuring temperature, humidity and differential pressure are common features of intelligent environment protection PDUs. The RCI is the air-conditioning safety performance indicator of any data center. Defined by the ASHRAE (American Association of Refrigeration and Air Conditioning) as the main air-conditioning improvement indicator and the parameter for rack cooling efficiency measurement and appraisal, this RCI was invented by air-conditioning expert Dr. Magnus Herrlin, who is also a senior ASHRAE member and host of the DOE's data center energy expert training and certification program. ASHRAE suggests to keep data center temperature between 18~27 C. The higher the temperature is, the more energy is saved. Temperature safety and air-conditioning performance should be benchmarked with RCI and RTI parameters.

The ISO50001 directive launched in June 2011 mandates every ISO50001 unit must set its critical energy use area as its prioritized management item. A data center, for its high electricity density, is definitely a critical energy use area and so must be the top goal in ISO50001 implementation. To be certified with ISO50001, the data center must look into its Power Usage Effectiveness (PUE) indicator, the ratio of total data center power consumption VS. information equipments power consumption. This index indicates the ratios of power used and wasted by a data center, which in turn, indicates the proportions of total power input used by IT equipments. The larger the data center's PUE value is, the bigger amount of power is consumed by the motor and environment protection infrastructure for secure IT equipment operation including PDU, UPS, air-conditioning system, input/output power supply and distribution system, and lighting system. In essence, a lower PUE value always represents better energy saving in data center. Most domestic data centers' PUE value is around 2.5 while their western counterparts' average 1.8 or even lower. The PUE value is a good indicator to the level of a data center's "green". ATEN eco-sensor software's comprehensive measurement function can accurately measure data center's PUE, RCI, and RTI value, identify existing cold and hot spots, as well as racks with improvement potential. RTI = (ΔTAHU /ΔTEquip) 100% ΔTAHU = Temperature drop across the air-handler units (airflow weighted average) ΔTEquip = Temperature rise across the IT-equipment (airflow weighted average)

The American Association of Refrigeration and Air-conditioning suggests that air-conditioning power consumption should be around 1/3 of that consumed by the information equipment. Most data centers set their temperature lower level to avoid shortened server life span caused by overheating. This is indicated by a relatively low RCI. If the air-conditioning is not set too low and the RCI remains normal, then some hot air that should be removed from the data center is returned into the air-conditioning's cooling passage to cool hot air rather than IT equipment, including the server, switch and router. This means more power is consumed by air-conditioning to reach the same cooling effects. ATEN's green data center environment and energy performance benchmarking system helps data center administrators acquire PUE, RCI, and RTI energy performance index to manage green data center's power usage, identify cold and hot spots for energy usage efficiency improvement for enhanced green energy saving results. This article highlights ATEN's green data center environment and energy performance benchmarking system eco-sensors, ATEN intelligent environment protection power distribution unit (eco PDU) and the applications of couple of important energy performance indicators. As mentioned at the beginning, the key to data center's energy saving management endeavor is a software system together with intelligent environment protection power distribution unit for energy performance indicator

measurement and appraisal. We hope this helps data center administrators in selecting appropriate data center energy saving management system.