Environmental Monitoring Environmental factors like heat, humidity and moisture pose a severe threat to your mission-critical infrastructure. These dangers can be minimized by incorporating a network of Geist sensors to collect data and alert users to potential threats. Geist s line of monitoring products allows users to observe conditions from a secure Web interface and receive SNMP, email, text message or voice call * alert notifi cations when environmental sensors detect a problem. The Web interface can display live video surveillance and environmental measurements including temperature, humidity, airfl ow, light, sound, power and water detection. Measurements are logged to track trends. Digital sensors can be controlled by programmed values or manually through the Web interface. Applications Data Center Viruses, spyware and network threats get most of the attention, but environmental factors like heat, humidity, water leakage, electricity, smoke and intrusion can be equally devastating to daily IT operations. Geist s line of environmental monitors enables administrators to strategically monitor the data center, server room and network closet environments to protect critical infrastructure and prevent system downtime hardware damage and data loss. Cold Storage Geist products are trusted by restaurants, cafeterias, grocery stores and warehouses across the globe to protect food quality by accurately monitoring cold storage facilities. Telecom Our environmental monitors are ideal for managing the conditions for base transceiver stations, cell sites and technical rooms to ensure sensitive equipment is operating effi ciently under appropriate conditions. Health Care Monitor and validate temperature among various environments within pharmaceutical plants, warehouses, hospitals, blood and tissue banks and laboratories. *Available with auto-dialer accessory. -1- geistglobal.com
> Free Tech Support > Free Firmware Updates > No Annual Fee Data Center Telecom Monitor Prevent Temperature Humidity/Dew Point Airflow Light x! $ Equipment Failure Downtime Loss of Revenue Loss of Reputation Strategically monitor data center, server room and network closet environments to protect critical infrastructure and prevent system downtime, hardware damage and data loss. Monitor climate and power conditions within base transceiver stations, cell sites, and technical rooms to ensure your equipment is running in optimal conditions. Sound Door Position Water Leaks Power Failure Voltage Alerts > Alert notifications via Email and SNMP Traps when user-adjustable thresholds are breached Health Care Cold Storage Amperage Kilowatt-Hour(s) Battery Video Surveillance > > Automation and control of external devices Outlet level power monitoring and switching capabilities with the GRS2 Monitor and validate temperature among various environments within healthcare facilities including hospitals, blood and tissue banks and laboratories. Geist s environmental monitors enable users to monitor cold-storage facilities among restaurants, cafeterias, grocery stores and warehouses across the globe to protect perishable inventory, ensuring food quality and safety. Variety of Environmental Monitors Available Geist environment monitors are used for a wide range of other applications including traffi c control boxes, climate-controlled storage, wine cellars, air-traffi c control communications closets, research laboratories, stability chambers, greenhouses, livestock, poultry farms and museums. Our products are fully scalable to meet various special needs. 877.449.4150-2-
GBB15 GBB15 POE Add built-in Power-over-Ethernet (POE) The small size and price makes this Webenabled climate monitor great for hot spots and other problem areas. This unit is especially useful for monitoring temperature and humidity conditions in various applications such as small computer rooms, network closets, server racks or any critical facility requiring climate control. Temperature, Humidity/ Dewpoint, Airfl ow Temperature 6 VDC (optional on GBB15-POE) GBB15 & GBB15 POE Specifications Ethernet Connection Optional Power-over-Ethernet (POE) 6 VDC Power Supply IP Reset Button Two Digital Sensor Ports (capacity of four external sensors) On-board Sensors Temperature Range: -13 F to 176 F (-25 C to 80 C), +/- 0.5 C Humidity: 5% to 95%, +/- 3% Dewpoint: -58 F to 185 F (-50 C to 85 C) Chassis Dimensions: 1.72 H x 5.22 W x 1.29 D FCC Part 15 Class A Conformance GBB100 GBB100 POE Add built-in Power-over-Ethernet (POE) The GBB100 is a self-contained unit with onboard temperature and humidity/dew-point sensors. It has an input capacity of eight external sensors (four digital and four analog) and an output of one NO/NC relay contact for triggering external devices like an auto-dialer. As with all other Geist environmental monitors, the GBB100 allows users to view remote conditions from a secure Web interface. In addition, emails, text messages and voice call * alert notifi cations can be generated when user-adjustable thresholds are exceeded. Leak Detection City Power Monitor -48 VDC Auto-dialer Temperature * auto-dialer required. GBB100 & GBB100 POE Specifications Ethernet Connection 6 VDC Power Supply Optional Power-over-Ethernet (POE) Power On Indicator Idle/Activity Indicator IP Reset Button One Digital Sensor Port (connect up to four using splitters) Four Analog Sensor Ports One Output Relay Max Switching Capacity: DC: 60V, 30W / AC: 30V rms, 1A On-board Sensors Temperature Range: -4 F to 176 F (-20 C to 80 C), +/- 0.5 C Humidity: 5% to 95%, +/- 3% Dewpoint: -58 F to 185 F (-50 C to 85 C) Chassis Dimensions: 1.6 H x 8.5 W x 2.5 D (with 19" mounting brackets) -3- geistglobal.com
GRSMini163 With 16 digital sensor ports, the GRSMini163 is ideal for applications that require a low-cost climate monitor and a large number of remote sensors. The GRSMini163 connects up to 16 digital and three analog sensors in a convenient 1U device. Satisfy ASHRAE standards by monitoring top, middle and bottom cabinet inlet temperatures on up to fi ve cabinets with a single GRSMini163. The addition of analog sensors allows parameter monitoring of water, smoke, power failure or room entry. Temperature, Humidity/ Dewpoint, Airfl ow Temperature Door Position Water City Power Monitor GRSMini163 Specifications Ethernet Connection 6 VDC Power Supply Power On Indicator Idle/Activity Indicator IP Reset Button 16 Digital Sensor Ports Three Analog Sensor Ports On-board Sensors Temperature Range: -22 F to 185 F (-30 C to 85 C), +/-.5 C Chassis Dimensions: 1.61 H x 17 W x 1.61 D FCC Part 15 Class A Conformance GRSE-B and GRSE2X16 The GRSE-B and GRSE2X16 contain fi ve on-board environmental sensors and additional sensor ports for connecting external digital and analog sensors. The GRSE2X16 comes with an audible alarm and LCD display. GRSE-B On-board Temp, Humidity/ Dewpoint, Airfl ow Sensors IP Reset Light and Sound Sensors GRSE2X16 Audible Alarm LCD Display Temperature RS2 Leak Detection Smoke Alarm GRSE-B/GRSE2X16 Specifications Ethernet Connection 6 VDC Power Supply Power On Indicator Idle/Activity Indicator IP Reset Button Five Digital Sensor Ports (capacity of 16 with splitters) Three Analog Sensor Ports LCD Display (RSE2X16) Audible Alarm (RSE2X16) On-board Sensors Temperature Range: -22 F to 185 F (-30 C to 85 C), +/-.5 C Humidity: 0-100%, +/- 5% Dewpoint: -22 F to 185 F (-30 C to 85 C) Airfl ow, Sound & Light: 0-99, relative Chassis Dimensions: 1.61 H x 17 W x 1.61 D FCC Part 15 Class A Conformance 877.449.4150-4-
GRSO GRSO POE Add built-in Power-over-Ethernet (POE) The GRSO offers climate monitoring with three relay outputs. Equipped with an onboard temperature sensor and six analog inputs, the GRSO supports up to 16 remote digital sensors. The relay outputs enable users to trigger external devices like autodialers, strobe lights or back-up A/C units on alarm or manually through the Web interface. RS2 City Power Monitor 60VDC Sensor Warning Light Contractor Auto-dialer GRSO & GRSO POE Specifications Ethernet Connection Power On Indicator 6 VDC Power Supply Idle/Activity Indicator Optional Power-over-Ethernet (POE) IP Reset Button Four Digital Sensor Ports (capacity of 16 with splitters) Six Analog Sensor Ports Three Relay Outputs Max Switching Capacity: DC: 60V, 30W / AC: 30V rms, 1A On-board Sensors Temperature Range: -22 F to 185 F (-30 C to 85 C), +/-.5 C Audible Alarm LCD Display Chassis Dimensions: 1.61 H x 17 W x 1.61 D FCC Part 15 Class A Conformance Environmental Monitor Comparison ENVIRONMENTAL MONITORS GBB15 GBB100 GRSMini163 GRSE-B GRSE2X16 On-board Sensors GRSO Temperature X X X X X X Humidity/Dewpoint X X X X Airfl ow X X Light Level X X Sound Level X X External Sensors Digital Sensor Ports 2 1 16 5 5 4 Maximum Digital Sensor Capacity 4 4 16 16 16 16 0-5 VDC Analog Sensor Ports 4 3 3 3 6 Hardware Features Optional built-in POE X X X Built-in Alarm Buzzer X Relay Outputs 1 3 LCD Display w/ Scrolling Measurements X X Rackmount 1U X X X X X Ethernet X X X X X X -5- geistglobal.com
RS-Wi Wireless Monitoring System The RS-Wi Wireless Gateway is designed for easy integration with Geist's DCiM systems. The convenient wireless design helps reduce installation costs associated with hard-wired sensors. An auto-discovery mechanism detects sensors as they are installed within the monitoring network. Wireless design 900MHz & 418MHz receivers Operates on a mesh network Receives transmissions up to 100 feet in open air with the 418MHz antenna RS-Wi Compatible Sensors Digital temperature sensor Digital temperature measurement and dry contact Receives transmissions up to a quarter mile in open air with the 900MHz antenna Provides direct alarm notifi cation Ability to output to Modbus, BACnet and SNMP Analog input sensor Analog input transmitter Point repeater Digital temperature/ humidity sensor Wireless Gateway 10/100BaseT Ethernet 10/100BaseT Ethernet Network Wireless Gateway RS-Wi as a mesh network RS-Wi Wireless Temperature Sensor Part # RS-Wi ENV-AS1 (0-20Ma transmitter) ENV-AS2 (0-5V transmitter) ENV-DIT (temp + dry contact sensor) ENV-MS (motion sensor) ENV-PR (point repeater) ENV-THS-2 (temp/hum sensor) ENV-TS (temp sensor) RS-Wi Wireless Gateway Description Wireless Gateway Analog Input (0-20MA), 418 MHz Wireless Transmitter Analog Input 0-5V, 418 MHz Wireless Transmitter Digital (DI) and Temperature Sensor, 418 MHz Wireless Transmitter Motion Sensor, 418 MHz Wireless Transmitter Point Repeater (Mesh), 418 MHz Receiver with 900 MHz Transceiver Temperature and Humidity Sensor, 418 MHz Wireless Transmitter Temperature Sensor, 418 MHz Wireless Transmitter Wireless Gateway RS-Wi as a network repeater 877.449.4150-6-
Analog Sensors Smoke Alarms City Power Monitor Leak Detection Photoelectric Smoke Alarm Part # SA9120F (120V) SA9220F (220V) The Photoelectric Smoke Alarm is designed for 120VAC/9VDC and 220VAC/9VDC single or multiple (tandem) station and specialty applications. The smoke alarms are equipped with a 9VDC battery backup as an auxiliary power source in the event of an electrical failure and feature a warning signal for a low or missing battery. Smoke Alarm Kit Part # SA-1 The Kidde Smoke Alarm will sound an alert upon detecting smoke. The kit will trigger the environmental monitor to send a notifi cation as confi gured. The smoke alarm has a back-up battery and a wired 120V plug. Carbon Monoxide Alarm Part # GRCP-2-100 US The City Power Monitor plugs into a standard outlet and sounds an alarm when city power is lost and backup power is activated. Direct Current Volts Sensors Part # G60VDCM 60VDC remotely monitors the charge of 0-60V telephone batteries or cell phone systems. Part # -48VDCM -48VDC is designed to monitor -48 volt telephone batteries. The sensor converts the positively grounded batteries into a negatively grounded 0-5VDC signal. No separate power supply is required. Part # 8706 (10' cable) 8707 (25' cable) 8708 (50' cable) 8709 (100' cable) Water-sensing kits feature detection cables that recognize the presence of water along the entire cable length. The kits discover moisture over a wide area such as the perimeter of a group of racks and cabinets. Analog Inputs on Device Fault Alarm C 1 2 3 C J-clips White (-) Green (+) Red (+) Black (-) Water Detect Wall-Mounted Components Interface Box Top View of Server Room Floor Water Sensor 5VDC Power Supply Leader cable Water sensing cable Current Transducer Part # CODCO1209F (120V) This 120VAC/9VDC single/multiple station detects monoxide and supports tandem interconnect capabilities. Cameras Call for details D-Link Wireless G network cameras connect to wired or wireless networks to remotely provide high-quality video surveillance. Part # CT 30/60/120 The Current Transducer monitors the current being drawn by a particular device or group of devices. It also measures current ranges of 30, 60 and 120 amps. The unit outputs 0 to 5 VDC (proportional to current). Part # RWS (20 ft cord) Part # RWS-100 (100 ft cord) The water sensor measures conductivity and indicates whether the sensor is dry, damp or completely immersed in water. Door Position Sensor Part # RDPS (30 ft wire) Part # RDPS-50/100 (50 or 100 ft wire) The Door Position Sensor detects unauthorized cabinet access. -7- geistglobal.com
Digital Sensors and Accessories Analog to Digital Converter PoE Splitter and Injector Kit 5-Port Splitter Part # CCAT-48VDCM Part # CCAT-CITY POWER Part # CCAT-CURRENT Part # CCAT-DIGITAL Part # CCAT-DOOR Part # CCAT-SMOKE ALARM Part # CCAT-WATER Analog to Digital converters, better known as the CCAT, converts an analog sensor for use with a digital sensor port. Useful for monitoring units that don't have an I/O port or for adding additional analog sensors. Temperature Sensor Part # RT-12/20/25/50/100 The Temperature Sensor comes in multiple cord lengths (12', 20', 25', 50', 100') to monitor temperature in a variety of locations. Sensor Details: Temperature: -40 C to 85 C or -40 F to 185 F; Accurate to +/-0.5 Part # POI-2002 (Injector) Part # POS-2002 (Splitter) Power any environmental monitor and/or Web camera over Ethernet using the PoE Spllitter and Injector kit. A standard (300' max) CAT5 is required to carry both data and power to each device. Temperature, Airflow, Humidity and Dewpoint Sensor Part # RTAFHD3-12/20/25/50/100 This sensor monitors temperature and humidity to identify hot spots and adjust the ambient temperature of your data center to reduce cooling power consumption while increasing effi ciency within ASHRAE guidelines. The sensor is plug-and-play with standard RJ12 jacks and comes in a variety of cord lengths (12', 20', 25', 50', 100'). Sensor Details: Accurate to +/-0.5 C within the normal operating range of 20 C to 45 C; Accurate to +/-2% RH within the normal operating range of 20% to 80% RH at 25 C; Extended operating range of -40 C to 85 C (-40 F to 185 F) Part # SP-5 The 5-port splitter simplifi es installation for multiple remote sensors. Connect up to 16 sensors. The splitter comes with one RJ12 plug, 5 receptacles and a 4' cord. -48 Volt DC Power Supply Part # -48VDCPS The -48VDC Power Supply delivers power to any Geist environmental monitor. PSTN and GSM Auto-Dialers Part # ADP-G06 (GSM auto-dialer) Part # ADP-T01 (PSTN auto-dialer) The relay controlled GSM and PSTN auto-dialers add an additional level of alert notifi cation by dialing preprogrammed phone numbers. Battery back-up ensures the autodialer delivers alerts even if its power source is lost. The dialer can be programmed to call up to nine different phone numbers. Each dialer contains two triggers, and each trigger can have its own pre-recorded message. 877.449.4150-8-
Digital Sensors and Accessories GTHD and GT3HD Host Daisy-chain to other sensors Daisy-chain to other sensors GT3HD GT3HD GTHD GTHD 3 cable 3 cable Part # GTHD (Temp, Humidity, Dew) Part # GT3HD (Temp 3x, Humidity, Dew) The GTHD/GT3HD sensors collect and transmit real-time temperature, humidity and dewpoint data to protect data center equipment from heat and moisture. Multiple sensors can be daisy chained using the remote sensor port. The GT3HD model offers two additional RJ12 ports to add remote temperature sensors in alternative locations within the server rack or data center. Sensor Details: Temperature Range: -4 F to 176 F (-20 C to 80 C), +/- 0.5 C Humidity: 5% to 95%, +/- 3% Dewpoint: -58 F to 185 F (-50 C to 85 C) 6 cable 6 cable The plastic enclosure mounts easily anywhere in the data center with screws, magnets or adhesive. Each GT3HD comes standard with a 10 (3.1M) uplink cord (50 (15.3M) cord is optional) and a 3 (.9M) and 6 (1.8M) temperature sensors. -9- geistglobal.com
Expertise In this swiftly changing, technology-driven industry, plenty of companies are forced to react to remain relevant. At Geist, we stay ahead of our competition by constantly, actively evolving to meet the demands of our customers. Through technical expertise and skilled engineering, we provide leading-edge products and comprehensive solutions for our trailblazing customers. Partnership Every employee is ready and eager to help solve our customers problems. Accessible and responsive, our team is committed to delivering exceptional personal service and support every day fulfi lling our mission of providing a premier customer experience. Tailored Geist has been customizing cost-effective solutions for clients for more than 65 years. It s part of our culture. We are committed to quickly meeting each specifi c customer need with technological expertise and unbeatable detail. Quality Geist is decidated to developing the highest performing products and most innovative solutions in the industry. From hand-soldered connections in our power strips, to enterprise level data center infrastructure management (DCiM) software, we consistently except our customers expectations. geistglobal.com