World s Greenest High Performance Data Center



Similar documents
Product description NCC Data Center

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Sovereign. The made to measure data centre

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Data Centers: Definitions, Concepts and Concerns

Datacentre South London Data sheet

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Strategic Data Centre Site Profiles Data Centre Co-Location London North

Specialty Environment Design Mission Critical Facilities

Data Center Components Overview

Europe s greenest data center

vcloud SERVICE Virtual Tech in partnership with Equinix - vcloud Service

Data Center Combined Heat and Power Benefits and Implementation. Justin Grau, Google Inc. Sam Brewer, GEM Energy

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

Strategic Data Centre Site Profiles. Data Centre Co-Location London East

COMMODITIZING THE DATA CENTER MARKET

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

19 Site Location, Design and Attributes. Site Location, Design and Attributes

De energievoorziening in 2040;

Contents Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

Previder Datacenters it starts here

Colocation. Introduction. Structure of the service. Service Description

Crowne Plaza Copenhagen Towers The world s greenest hotel

Overview of Green Energy Strategies and Techniques for Modern Data Centers

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

NEW JERSEY CENTER OF EXCELLENCE

Data Center Solutions

Aurinkolämpömarkkinat Skandinaviassa ATY Aurinkoseminaari Jari Varjotie, CEO

Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency. Steve Hammond NREL

DATA CENTRE DESIGN AND

Data Center Facility Basics

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

Data Centre Southeast AMS 5, Netherlands Highly connected, premium data centre.

DOE Data Center Energy Efficiency Program

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

How green is your data center?

GREEN DATA CENTER DESIGN

Data Center Checklist

Energy Strategic Plan Los Angeles Community College District Community College League Conference

European Code of Conduct for Data Centre. Presentation of the Awards 2016

Every business owns precious data and every business should recognise the risk of losing their data. Natural Disaster

hong kong//china data center specifications tel: fax: internet + intellectual property + intelligence

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

European Business Reliance Centres when Commodity serves Green IT

ICT and the Green Data Centre

NY-1 DATACENTER AT A GLANCE. NY-1 is a Tier III-rated, SAS SSAE16 and HIPAA-certified data center

Technical specifications. Containerized data centre NTR CDC 40f+

Integrating renewable energy sources and thermal storage

Subject: County of Los Angeles Data Center Space Requirement

Our Hosting Infrastructure. An introduction to our Platform, Data Centres and Data Security.

Automation's Modular Containerized Datacenter Solutions

Smart solutions for fleets of all types & sizes of power generation. Marcus König, E F IE SGS / September 2013

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S.

Energy Storage Activities at New York Power Authority

Data Centre Harbour Exchange Square Campus, London Access to unrivalled connectivity.

SimSafe Data Centre Standards and Accreditation

DATACENTER Vienna 1. Scalable, Safe and Innovative

Eni Green Data Center - Specification

Datacentre Reading East 2 Data sheet

Green Data Centre Design

Ringing at the Door. Boiling an egg. Moving by car. Flows of solar energy. There is no energy crisis. How to boil an egg?

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Improving Data Centers Energy Reliability & Efficiency. December 2015

Siemens turbine solutions for urban cogeneration

Enabling an agile Data Centre in a (Fr)agile market

Case Study. Cool and green: Citigroup s Frankfurt Data Center

Data Center Energy Use, Metrics and Rating Systems

Feasibility Study for Mobile Sorption Storage in Industrial Applications

Fuel cell microchp: Greener and cheaper energy for all

Legacy Data Centres Upgrading the cooling capabilities What are the options?

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency.

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How

Greening Data Centers

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Energy efficient data centre cooling. InRack Cooling & The Intelligent Cooling System. aircold.dk

PAYGO for Data Center -- Modular Infrastructure

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Cost Analysis of District Heating Compared to its Competing Technologies

Introduction to Datacenters & the Cloud

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Sustainable Schools Renewable Energy Technologies. Andrew Lyle RD Energy Solutions

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering % guaranteed uptime

Transcription:

World s Greenest High Performance Data Center

EcoDataCenter Sustainability for future generations

Our Services Colocation Data Center for Mission Critical Requirements Lockable racks, cages, private rooms or own buildings Totally 3 buildings with 11.300 m 2 each Totally 18 MW fully redundant power and cooling Customer office space and storage facility Multiple redundant fiber optic and cross connect options On site support and remote hands Located in Falun, 200 km northwest from Stockholm Average annual temperature 6 C 73 hours > 25 C 436 hours > 20 C (annually) Falun Stockholm

Our Data Center

Our Value Proposition World's Greenest Data Center World Class Performance Tier IV First in North Europe Greener means Lower Cost

World's Greenest Data Center PUE < 1,15 World s Greenest Electricity Mix Energy Efficient Tier IV Design Heat Waste Reuse ERE = 0,45

World s Greenest Electricity Mix 100% Renewable 7 g CO 2 eq. /kwh CO 2 emissions (life cycle analysis) 0,75 Primary energy Factor (High resource Efficiency) Hydroelectric power locally from Sundborn Power Station and 715 MW from regional power stations with regional 130 kv grid CHP plant with secondary forest fuels 16 MW Wind power 5 x 2 MW 3,484 hrs production (39.8%) during 2013 Own Solar PV cell park 2 MW

World's Greenest Data Center PUE < 1,15 World s Greenest Electricity Mix Energy Efficient Tier IV Design Heat Waste Reuse ERE = 0,45

Power Usage Effectiveness PUE = Total Energy* IT Energy EcoDataCenter Tier IV 1,15 SuperNap Tier IV ViaWest Lone Mountain Tier IV 1,18 1,20 Facility Energy Reduced by 77% Uptime Institute 2013 Data Centre Industry Survey 1,65 US Environmental Protection Agency 1,91-0,50 1,00 1,50 2,00 2,50 * Total Energy = Facility Energy + IT Energy

PUE < 1.15 Energy Efficient Tier IV Design Ultra Efficient Ultra Efficient Optimized Energy Electrical Cooling Air Efficient System Plant Management Building

World's Greenest Data Center PUE < 1,15 World s Greenest Electricity Mix Energy Efficient Tier IV Design Heat Waste Reuse ERE = 0,45

Heat Island around Data Centers Power Usage Effectiveness Energy Reuse Effectiveness PUE = Total Energy IT Energy ERE = Total Energy Reused Energy IT Energy 100% of all electricity used in servers is converted to heat waste PUE = ERE Global Warming

Our Energy Ecosystem Hydro Power Wind Power Solar Power Data Center Power Cooling Cooling Waste Heat Heating District Heating & Cooling System Forest Fuels Combined Cooling Heating & Power Plant Wood pellets Heating Plant

Our Heat Balance Warm season Excess heat in CHP plant used to cool data center during warm season with steam driven absorption chiller 35% of hours per year Cold season Waste heat in data center reused to heat city during cold season with steam driven absorption heat pump 65% of hours per year Data Center Cooling Waste Heat Heating District Heating & Cooling System Combined Cooling Heating & Power Plant ERE 0,45

CO 2 emissions -20 g CO 2 eq /kwh electricty

Our Value Proposition World's Greenest Data Center World Class Performance Tier IV First in North Europe Greener means Lower Cost

World Class Performance Uptime Multi-Tier Data Center Uptime for Tier IV 100% World Class Physical Security Hi Density 20 kw available for all racks

Tier IV Design Certified Colocation DC s

Tier IV Power and Cooling Infrastructure Power Four separate electrical systems (transformer, generators, UPS, PDU) Multi-tier power supply (Tier IV and III) Redundant high & medium voltage supply 2 own CHP power plants for backup Busway with full flexibility in PDU power (16A 1-P, 16A 3-P, 32A 1-P, 32A 3-P, 63A 1-P, 63A 3-P) Cooling Two fully separate cooling circuits (A + B) Primary cooling from centralized CCHP plant with absorption chiller and absorption heat pump for heat reuse Secondary cooling with free cooling and Turbocor compressor CRAH with hot/cold air containment

World Class Performance Uptime Multi-Tier Data Center Uptime for Tier IV 100% World Class Physical Security Hi Density 20 kw available for all racks

Security Zone System (4-5 Zones) Standby generators Cooling room A1 Standby generators Cooling room B1 Cooling room B2 Data Rooms Data Rooms S t o r a g e S t o r a g e E n t r a n c e Standby generators Cooling room A2 Standby generators

Security Systems Precast concrete walls for fire and intrusion protection VESDA smoke detection Argonite Fire Supression Fire alarm High protection locks High protection doors Advanced access control systems Video surveillance Alarm system

World Class Performance Uptime Multi-Tier Data Center Uptime for Tier IV 100% World Class Physical Security Hi Density 20 kw available for all racks

High Density Colocation 20 kw power and cooling available for all racks Full flexibility to change capacity with busway

Our Value Proposition World's Greenest Data Center World Class Performance Tier IV First in North Europe Greener means Lower Cost

Our Cost Position Energy Opex Capex

Reduced Energy Cost EcoDataCenter Cost Base Case PUE 1,65 Energy Efficiency PUE 1,15 vs. 1,65 Waste Heat Reuse Energy Tax Reduction Own Wind Power Possible Energy Tax Reduction DC > 5 MW Alternative Case

Our Value Proposition World's Greenest Data Center World Class Performance Tier IV First in North Europe Greener means Lower Cost

EcoDataCenter Healthy environment for future generations