Wireless Multi-Zone HVAC Control



Similar documents
Heat Pump Training System

Automatic Storage and Retrieval System Flexible Manufacturing System

Refrigeration Training System

Three-Phase Motor Starters

Alignment and Couplings

3466 Building Energy Management Training Systems

Three-Phase AC Power Circuits

Variable Air Volume - VAV

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

HVAC Processes. Lecture 7

Workshop 7 PC Software - Tracker


SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Digi-Motor Installation Guide

Aurora UPC ZS Zone Sensors User Guide

INSTALLER S & OWNER S MANUAL

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Lighting and Fire Alarm Training System Add-On

Transmission Lines in Communication Systems FACET

Using Time-of-Day Scheduling To Save Energy

HVAC Systems in Schools & Commercial Buildings and Radon

User Manual THR840DUK Digital Thermostat

T7560A,B,C Digital Wall Module

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No

Electricity Fundamentals

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

Fan Coil EC Motor Control

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Portable Air Conditioner

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Ademco Vista-20P/First Alert FA-168C Basic Commands

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

Manual Ranging MultiMeter

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

StorTrends 3400 Hardware Guide for Onsite Support

REMOTE CONTROL MANUAL

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Business/Home GSM. Alarm System(III) Installation and Users guide

Business/Home GSM Alarm System. Installation and User Manual

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

WeatherLink for Alarm Output. Introduction. Hardware Installation and Requirements. Addendum

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Air Conditioning System

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Building Energy Systems. - HVAC: Heating, Distribution -

Insulation Resistance Monitoring System (IRMS) Operator Manual 96A0257 Rev. D

DC-8706K Auto Dial Alarm System

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

A/C-HEATER SYSTEM - AUTOMATIC

Failure code manual. content

Thyristor & Power Control Circuits

SFC-200 SERIES LCD FIRE ALARM PANEL

Business/Home. GSM Alarm system

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

AIR CONDITIONER INSTALLATION MANUAL

PSTN Home Alarm System

Quanser NI-ELVIS Trainer (QNET) Series: QNET HVAC. Heating, Ventilation, and Air Conditioning (HVAC) User Manual. User Manual

IQAN MDM Operation Manual

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Rev. No. 0 January 5, 2009

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Using your LED Plus keypad

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

T5000 T000 LCD Digital Fan Coil Thermostat

DUCT TYPE AIR CONDITIONER

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

Fundamentals of HVAC Control Systems

Drayton Digistat +2RF/+3RF

VSD Series Drives. November 2009 Supersedes September Powered by Eaton Technology. User Manual

Online UPS. PowerWalker VFI 1000R/1U

USER S MANUAL HSC-24A

T-100-R Installation Guide

Controller Automation, Model II+

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay

YSmart Technology Co.,Ltd

Mobile Device Power Monitor Battery Connection Quick Start Guide

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

14. Troubleshooting Guide

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Tebis application software

ADEMCO 4500 Thermostat

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

Transcription:

Refrigeration, Air Conditioning, Heating, and Ventilation Wireless Multi-Zone HVAC Control Courseware Sample 20588-F0 A

First Edition Published July 2014 2014 by Lab-Volt Ltd. Printed in Canada All rights reserved ISBN 978-2-89747-141-5 (Printed version) ISBN 978-2-89747-143-9 (CD-ROM) Legal Deposit Bibliothèque et Archives nationales du Québec, 2014 Legal Deposit Library and Archives Canada, 2014 No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical, photocopied, recorded, or otherwise, without prior written permission from Lab-Volt Ltd. Information in this document is subject to change without notice and does not represent a commitment on the part of Lab-Volt. The Lab-Volt materials described in this document are furnished under a license agreement or a nondisclosure agreement. The Lab-Volt logo is a registered trademark of Lab-Volt Systems. Lab-Volt recognizes product names as trademarks or registered trademarks of their respective holders. All other trademarks are the property of their respective owners. Other trademarks and trade names may be used in this document to refer to either the entity claiming the marks and names or their products. Lab-Volt disclaims any proprietary interest in trademarks and trade names other than its own.

The following safety and common symbols may be used in this manual and on the Lab-Volt equipment: Symbol Description DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. CAUTION used without the Caution, risk of danger sign, indicates a hazard with a potentially hazardous situation which, if not avoided, may result in property damage. Caution, risk of electric shock Caution, hot surface Caution, risk of danger Caution, lifting hazard Caution, hand entanglement hazard Notice, non-ionizing radiation Direct current Alternating current Both direct and alternating current Three-phase alternating current Earth (ground) terminal A Wireless Multi-Zone HVAC Control v

Symbol Description Protective conductor terminal Frame or chassis terminal Equipotentiality On (supply) Off (supply) Equipment protected throughout by double insulation or reinforced insulation In position of a bi-stable push control Out position of a bi-stable push control vi Wireless Multi-Zone HVAC Control A

Preface...xi About This Manual... xiii To the Instructor... xv Introduction HVAC Systems... 1 DISCUSSION OF FUNDAMENTALS... 1 What is HVAC?... 1 Anatomy of an HVAC system... 2 Rooftop unit... 3 Rooftop unit controller... 8 Multi-zone HVAC... 10 In the zone... 10 Multiple zones... 11 Heating vs cooling... 12 The concepts of heat and energy... 12 Heat transfer mechanisms... 13 Conduction... 13 Convection... 14 Radiation... 15 Exercise 1 Familiarization... 17 DISCUSSION... 17 The Multi-Zone Wireless Control Training System... 17 System overview... 17 Power source... 18 Control transformer... 19 Rooftop unit controller... 21 Analog controller... 23 Floating controller... 24 Main module... 27 PROCEDURE... 31 Set up and connections... 31 Configuring the analog controller... 35 Configuring the floating controller... 38 Configuring the RTU controller... 40 Testing the controllers... 43 Exercise 2 Rooftop Unit Control... 49 DISCUSSION... 49 Zoning information... 49 Behavior of the RTU... 50 Scheduling... 50 Free cooling with the economizer... 51 Static pressure and the role of the bypass damper... 52 A Wireless Multi-Zone HVAC Control vii

Analog control... 53 PROCEDURE... 54 Set up and connections... 54 User menu of the RTU controller... 56 Setting the system mode... 56 Setting the schedule for one day... 56 Setting the clock... 57 Fan control and cooling... 57 Free cooling scenario (economizer)... 58 Static pressure control with the bypass damper... 58 Heating... 59 Guided troubleshooting... 59 Inserting a fault... 59 Observation... 59 Deduction... 59 Measurements... 59 Conclusion... 60 End of the exercise... 60 Exercise 3 Single-Zone Control (Floating and Analog)... 63 DISCUSSION... 63 Floating control compared to analog control... 63 Wiring of the controller outputs... 64 What is a terminal box?... 66 Supplemental (baseboard) heating... 67 Zone sensors... 67 Zone occupancy... 67 Occupancy status override... 68 Changes in cooling and heating set points... 68 Example... 68 Modification to the set point on the zone controller... 69 PROCEDURE... 70 Set up and connections... 70 Floating control (single zone)... 73 Local override... 74 Stand-by mode... 74 Occupied mode... 75 Analog control (single zone)... 76 Troubleshooting... 79 End of the exercise... 80 viii Wireless Multi-Zone HVAC Control A

Exercise 4 Multi-Zone Control... 83 DISCUSSION... 83 Managing the zones... 83 Voting system... 83 The weight of a zone... 83 Zone control scenarios... 84 RTU in cooling mode... 84 RTU in heating mode... 85 PROCEDURE... 86 Set up and connections... 86 Zone reaction when the RTU is in cooling mode... 90 Zone reaction when the RTU is in heating mode... 92 Analysis... 93 RTU in cooling mode... 93 RTU in heating mode... 95 Battle of the zones... 96 Final troubleshooting... 97 End of the exercise... 99 Appendix A Equipment Utilization Chart... 103 Appendix B Conversion Table... 105 Appendix C Answers to Test Questions... 107 Index... 109 Bibliography... 111 We Value Your Opinion!... 113 A Wireless Multi-Zone HVAC Control ix

This line of products introduces students to the basic principles of heating, ventilation, and air conditioning (HVAC) systems. It covers all components commonly used in HVAC systems today, and teaches students the skills required to work in the HVAC field. Throughout the activities of the manuals, students develop practical knowledge on how to install, maintain, and troubleshoot HVAC systems, and they become familiar with a large variety of HVAC systems as well as with their different characteristics. The training systems in this line of products are specially designed for full modularity. This particularity allows them to be used to implement a wide variety of HVAC systems and circuits. The training systems also incorporate actual residential, industrial, and commercial devices in order to give students an experience that is as close as possible to actual work in the HVAC field. A Wireless Multi-Zone HVAC Control xi

Manual objectives When you have completed this manual, you will be able to: understand how HVAC systems, sub-systems, and components operate. wire HVAC control circuits. read and understand technical documents such as diagrams. identify and document potential malfunctions and correct them if possible. Safety considerations Safety symbols that may be used in this manual and on the Lab-Volt equipment are listed in the Safety Symbols table at the beginning of the manual. Safety procedures related to the tasks that you will be asked to perform are indicated in each exercise. Make sure that you are wearing appropriate protective equipment when performing the tasks. You should never perform a task if you have any reason to think that a manipulation could be dangerous for you or your teammates. Reference material Refer to the textbook titled Refrigeration and Air Conditioning Technology written by Bill Whitman, Bill Johnson, John Tomczyk, and Eugene Silberstein. Additional information can be found on the website of the different component manufacturers. Prerequisite Basic electrical knowledge is a prerequisite to this series of manuals. It is assumed that you have a general understanding of these concepts: Voltage, current, and power, both in dc and ac circuits Basic electrical components (resistor/potentiometer, inductor, capacitor, diode, transistor) Ohm s law Series and parallel circuits Electrical measurement using a digital multimeter (DMM) Systems of units Units are expressed using the U.S. customary system of units followed by the units expressed in the SI system of units (between parentheses). A Wireless Multi-Zone HVAC Control xiii

You will find in this Instructor Guide all the elements included in the Student Manual together with the answers to all questions, results of measurements, graphs, explanations, suggestions, and, in some cases, instructions to help you guide the students through their learning process. All the information that applies to you is placed between markers and appears in blue. Accuracy of measurements The numerical results of the hands-on exercises may differ from one student to another. For this reason, the results and answers given in this manual should be considered as a guide. Students who correctly performed the exercises should expect to demonstrate the principles involved and make observations and measurements similar to those given as answers. A Wireless Multi-Zone HVAC Control xv

Sample Exercise Extracted from the Student Manual and the Instructor Guide

EXERCISE OBJECTIVE In this exercise, you will: Connect the RTU controller inputs and outputs to the RTU section of the main module. Observe how the RTU controller commands the fan, the heating elements, and the cooling elements. Observe how the RTU controller controls the economizer and bypass dampers. Learn the difference between occupied and unoccupied modes. Troubleshoot the system. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Zoning information Behavior of the RTU Scheduling. Free cooling with the economizer. Static pressure and the role of the bypass damper. Analog control DISCUSSION Zoning information The following figure illustrates the information that the RTU controller exchanges with the zone controllers. In short, the RTU controller informs the zone controllers of the outdoor temperature, the current occupancy mode, and the RTU active mode. For their part, the zone controllers only ask for hot or cool air. A Wireless Multi-Zone HVAC Control 49

Exercise 2 Rooftop Unit Control Discussion RTU controller System occupancy (schedule) Active mode (hot air / cool air supplied) Outdoor air temperature - OS Heating / Cooling demand Heating / Cooling demand Zone controller 1 Zone controller 2 Figure 37. Information exchange between the RTU controller and the zone controllers. Behavior of the RTU It is not easy to get a grasp of how the whole RTU operates. Therefore, let us consider some simpler, separate tasks that it accomplishes. Scheduling Outside of working hours, having cooler or hotter temperatures than normal does not create discomfort to anyone. Additionally, extending the acceptable temperature range provides for substantial energy savings because the heating and cooling elements can be turned off for longer periods. 9 am 5 pm 9 am 5 pm 9 am 5 pm 9 am 5 pm 9 am 5 pm Closed Closed Closed Figure 38. The occupied period may correspond to regular office hours. 50 Wireless Multi-Zone HVAC Control A

Exercise 2 Rooftop Unit Control Discussion Scheduling means programming the RTU controller so that it behaves differently when the building is occupied than when it is not. Figure 39 shows how a week can be divided into occupied (green) and unoccupied (light gray) periods. Special events may also be added to account for holidays. Figure 39. Occupied period (in green) on a supervisory controller. In occupied mode, the blower is always on to maintain a proper ventilation of the building. In unoccupied mode, the blower can be turned off if the zone temperatures fall within the unoccupied temperature dead band and the heating and cooling elements are off. However, the blower is turned back on if a zone has a heating or cooling demand to make the conditioned air reach the zone. a The bypass damper opens if the blower is off to avoid overpressure when the blower restarts. Free cooling with the economizer There are two means by which the RTU provides cool air to the zones: using cooling coils through which the supplied air passes, or opening a damper that lets some cool air from outside enter as shown in Figure 40. The latter case is called free cooling because no energy is used to chill the air. However, this scenario is only possible when the outside air is below a certain temperature set point and the zones require cooling. With the multi-zone system, this means that: the outdoor temperature (OS) is below the free cooling set point (Chngstpt) of 55 F (13 C) by default. a the zone temperature is higher than the current cooling set point (Occ CL or Unocc CL). Higher supply temperature (DS) accelerates the opening of the economizer damper. A Wireless Multi-Zone HVAC Control 51

Exercise 2 Rooftop Unit Control Discussion Fresh air damper opens Return air damper closes Figure 40. Free cooling. Static pressure and the role of the bypass damper In a variable air volume (VAV) system, the flow of air varies depending on the opening and closing of various dampers. When all zone dampers are fully open, maximum airflow is needed. On the other hand, if many zone dampers go to their minimum opening position, the need for air supply decreases. In this case, static pressure in the supply duct rises and more air enters the zone for a same damper opening. However, if static pressure somehow remains stable, the air flow rate delivered to the zones can stay relatively constant. To regulate the supplied air flow and prevent overpressure, the fan speed or the opening of a bypass damper is varied according to the reading of a pressure transmitter. The multi-zone system shown in Figure 41 is an example where the fan speed remains constant but a bypass damper opens as static pressure increases. Pressure reading Bypass damper opens as pressure increases Figure 41. The bypass damper opens when static pressure is high. 52 Wireless Multi-Zone HVAC Control A

Exercise 2 Rooftop Unit Control Discussion Analog control Electrical signals convey information to and from the controllers. Each controller analog input receives a low-level electrical signal (in volts or milliamperes) that corresponds to a real physical value. For example, the static pressure (SP) signal of the RTU controller is a 0-5 V input. Figure 42 shows that 0 V corresponds to 0 inh 2 O (0 Pa) and 5 V corresponds to 2 inh 2 O (500 Pa). If 2.5 V are received, this means a pressure of 1 inh 2 O (250 Pa). 0 inh 2 O (0 Pa) 1 inh 2 O (250 Pa) 2 inh 2 O (500 Pa) 0 V 2.5 V 5 V Figure 42. Correspondence between an analog input signal and static pressure. The same principle applies to analog outputs. The multi-zone system dampers operate on 0-10 V signals. If the RTU controller sends 5 V, the damper should open half-way. Note that, in this case, the damper will remain partly open even if no voltage is received to ensure minimal air circulation. A Wireless Multi-Zone HVAC Control 53

Exercise 2 Rooftop Unit Control Procedure Outline PROCEDURE OUTLINE The Procedure is divided into the following sections: Set up and connections User menu of the RTU controller Setting the system mode. Setting the schedule for one day. Setting the clock. Fan control and cooling Free cooling scenario (economizer). Static pressure control with the bypass damper Heating Guided troubleshooting Inserting a fault. Observation. Deduction. Measurements. Conclusion. End of the exercise PROCEDURE Set up and connections This section shows the recommended setup and wiring to test the RTU controller behavior. 1. Install all the system modules in the workstation as shown in Figure 43. Figure 43. All modules installed on the workstation. 54 Wireless Multi-Zone HVAC Control A

Exercise 2 Rooftop Unit Control Procedure 2. Make sure that the main power switch on the power source is set to the O (off) position, and then connect the module to an ac power outlet. Always check the power specification of a module before connecting it to the power source. 3. Use the test leads to connect the power source, control transformer, RTU controller, and RTU as shown in Figure 44. 24 V Figure 44. Connecting the RTU. 4. Set the controls of the RTU section according to Table 15. Table 15. RTU section settings (main module). Button or switch Fresh air flow (AI) Static pressure (SP) Outdoor temperature (OS) Return temperature (RS) Supply temperature (DS) Setting 10 000 CFM (283 m 3 /min) 1 inh 2 O (250 Pa) 70 F (21 C) 70 F (21 C) 70 F (21 C) A Wireless Multi-Zone HVAC Control 55

Exercise 2 Rooftop Unit Control Procedure 5. Connect the 24 V - HOT and 24 V - COM terminals of the floating zone controller to the control transformer so that the module can be powered. Set the controls according to Table 16. Table 16. Floating zone controller settings. Button or switch Temperature sensor Occupancy sensor Temperature CO 2 level Setting Remote (RS) Open 70 F (21 C) 0 ppm 6. Ground all modules by connecting them in series to one of the ground terminals of the power source. 7. Once everything is properly connected, turn the power source on. The display of each controller should light up. 8. Make sure the default parameters from Exercise 1 are entered in the RTU controller and in the floating zone controller. User menu of the RTU controller Setting the system mode 9. Press the MENU button briefly to access the user menu. If you are in unoccupied mode, the controller will ask if you want to override the schedule (Override Sched? Y/N). Press NO. a The user menu is different from the configuration menu. You need to press MENU for several seconds to access the configuration menu. If the controller is already in override mode (Cancel Ovrd? Y/N), press YES to cancel the override. 10. When asked to set the system mode (Sys mode set? Y/N), press YES, select Sys mode auto using the arrows, and press YES again to confirm your choice. The auto mode allows the RTU controller to switch between heating and cooling modes. Setting the schedule for one day 11. The RTU controller follows a schedule to operate according to preset occupied and unoccupied periods. By default, two events are entered each day: The time when the occupied period starts (e.g., 8 AM) 56 Wireless Multi-Zone HVAC Control A

Exercise 2 Rooftop Unit Control Procedure The time when the unoccupied period starts (e.g., 5 PM) Press NO until you obtain the current day (e.g., Tuesday set? Y/N). Then press YES. 12. Set the occupied period to start in about 10 minutes from now so we can observe the change of mode. Use the buttons to modify the time, press YES to confirm the value, and note the value below. Occupied start time: 13. Set the unoccupied period to start after you are done with this exercise. Use the buttons to modify the time and press YES again to confirm the value. Unoccupied start time: Setting the clock 14. In order to establish a meaningful schedule, we need to set the correct time (Clock Set? Y/N). If necessary, press YES and use the buttons to establish the time, day, and time format. 15. Exit the menu. Fan control and cooling 16. What is the mode indicated on the RTU controller and on the zone controller? Unoccupied for both 17. What is the state (on/off) of the blower and bypass damper? Why is it so? The blower is off and the bypass damper is open because we are in unoccupied mode and the zone controller does not call for cooling or heating (the temperature is between 65 F and 80 F). 18. Turn up the zone temperature to a maximum. Describe what happens with the blower and why. a The LEDs under the blower, snowflake, and fire icons on the controllers are good indicators of what is going on with the controllers. The blower starts within a few seconds because the zone controller asks for cooling. Note that the bypass damper closes at least in part. A Wireless Multi-Zone HVAC Control 57

Exercise 2 Rooftop Unit Control Procedure 19. Wait until the RTU controller switches to occupied mode (see step 12). What is the mode on each controller? RTU controller: occupied Zone controller: stand-by 20. Turn the OCCUPANCY SENSOR (BI1) switch to CLOSED as if someone entered the zone at the beginning of the workday. What is the mode on each controller now? RTU controller: occupied Zone controller: occupied Free cooling scenario (economizer) 21. Since it is hot in the zone (zone temperature is maximum), the RTU is in cooling mode with the cooling elements on. Turn down the OUTDOOR TEMPERATURE (OS) to MIN to simulate that the air outside the building is cool. Observe the indicators on the main module and describe how the RTU controller responds to the situation. The cooling elements turn off and the economizer damper opens. We are in free cooling mode. 22. Return the zone temperature and outdoor temperature to 70 F (21 C) to stabilize the system. Since the cooling demand is dropping, you might be able to see that only one of the two cooling stages remains on. Static pressure control with the bypass damper 23. Increase the static pressure to the maximum level. Describe what happens with the bypass damper with more pressure in the supply air duct. The bypass damper opens completely to try to diminish the pressure in the duct. 24. Decrease the static pressure to the minimum level. Describe what happens with the bypass damper. The bypass damper closes entirely to help build some pressure in the duct. 25. Return the static pressure to 1 inh 2 O (250 Pa). 58 Wireless Multi-Zone HVAC Control A

Exercise 2 Rooftop Unit Control Procedure Heating 26. Diminish the zone temperature very slowly. Describe what happens as the temperature goes down. If the cooling elements were on, they turn off. Then the first stage of heat is activated, followed by the second stage. 27. Return the zone temperature to 70 F (21 C). Guided troubleshooting Inserting a fault 28. Actuate fault number four on the RTU controller module. This fault will likely disrupt the way the module operates. The question is how. Observation 29. Operate the system in cooling, free cooling, and heating modes. Describe what you observe below. The system operates normally in cooling and in heating modes. However, when the temperature is high in the zone and the outdoor temperature is low, there is something wrong. The cooling stages are turned off for free cooling, but the economizer damper does not open. Deduction 30. What could be the cause(s) of the trouble? There seems to be a problem with the economizer damper. Measurements 31. Because the conditions for free cooling make the RTU controller stop the cooling stages, this is probably a problem with the economizer damper. Use a multimeter to check the economizer output signal on the RTU controller. The multimeter must be in dc voltage mode and the probes connected between the EC and C terminals. Record your reading below. 0 V A Wireless Multi-Zone HVAC Control 59

Exercise 2 Rooftop Unit Control Conclusion Conclusion 32. Clearly, the economizer damper cannot open if it does not get a signal from the controller. Remove the fault. What does the multimeter read? (close to) 10 V 33. We see that the economizer opens as soon as the fault is removed to act according to the free cooling mode. It was a case of bad wiring between the economizer and RTU controller output. End of the exercise 34. Make sure that no fault remains on the modules. 35. Turn off the power source. 36. Disconnect all leads and arrange the modules and leads neatly in preparation for the next laboratory exercise. CONCLUSION In this exercise, you connected the RTU controller to the main module. You entered a schedule and you observed the behavior of the system when the zone temperature, outdoor temperature, or static pressure changes. You also performed a guided troubleshooting activity. REVIEW QUESTIONS 1. Why does the RTU have occupied and unoccupied periods? The unoccupied periods permit energy savings because the fan can be turned off and the heating and cooling stages are off more often. 2. Which heating set point is the highest: the occupied or unoccupied mode set point? Explain. The occupied mode set point is the highest. In other words, the temperature cannot fall as much in occupied mode before heating is triggered. 3. Which cooling set point is the highest: the occupied or unoccupied mode set point? Explain. The unoccupied mode set point is the highest. In other words, the temperature can increase more in unoccupied mode before cooling is triggered. 60 Wireless Multi-Zone HVAC Control A

Exercise 2 Rooftop Unit Control Review Questions 4. What conditions are required for free cooling to happen? The zone controllers must call for cooling and the outside air must be cool enough (below 55 F (13 C) in our case). 5. What is the purpose of the bypass damper? The bypass damper helps regulate the static pressure in the air supply duct, and hence, the air flow. The bypass damper is also open when the blower is off to avoid overpressure when the blower restarts. A Wireless Multi-Zone HVAC Control 61

Whitman, William C., Johnson, William M., Tomczyk, John A., and Silberstein, Eugene, Refrigeration and Air Conditioning Technology, 7 Th ed., Clifton Park, NY: Delmar, Cengage Learning, 2013, ISBN 1-111-64447-0. Herman, Stephen L. and Sparkman, Bennie L., Electricity & Controls for HVAC/R, 6 th ed., Clifton Park: Delmar Cengage Learning, 2010, ISBN 978-1-4354-8427-6. Miller, Rex and Miller, Mark, Electricity and Electronics for HVAC, 1 st ed., New York: McGraw-Hill Companies, 2007, ISBN 0-07-154270-1. Standair inc., Z-air Pour un zonage simple et efficace Manuel technique, Laval (Québec). A Wireless Multi-Zone HVAC Control 111