Liquid Chromatograph Mass Spectrometer LCMS-IT-TOF C146-E093D



Similar documents
C146-E093B LCMS-IT-TOF. Shimadzu High-Speed Liquid Chromatograph Mass Spectrometer LCMS-IT-TOF

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Supplementary Materials and Methods (Metabolomics analysis)

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Pesticide Analysis by Mass Spectrometry

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

AMD Analysis & Technology AG

Introduction. Methods. Sample Processing

Background Information

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

LC-MS/MS for Chromatographers

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Overview. Purpose. Methods. Results

A Streamlined Workflow for Untargeted Metabolomics

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Waters Core Chromatography Training (2 Days)

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

High Resolution LC-MS Data Output and Analysis

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Electrospray Ion Trap Mass Spectrometry. Introduction

Micromass LCT User s Guide

13C NMR Spectroscopy

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

The Theory of HPLC. Gradient HPLC

Mass Frontier Version 7.0

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

MS/MS analysis of Polyphenols

Mass Spectrometry Based Proteomics

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

How To Use An Acquity Qda Detector

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Pep-Miner: A Novel Technology for Mass Spectrometry-Based Proteomics

Mass Frontier 7.0 Quick Start Guide

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Appendix 5 Overview of requirements in English

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

New drugs of abuse? A case study on Phenazepam & Methoxetamine

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Analyzing Small Molecules by EI and GC-MS. July 2014

Expectations for GC-MS Lab

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

WATERS QUANTITATIVE ANALYSIS solutions

Chemical analysis service, Turner s Green Technology Group

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Analysis of Liquid Samples on the Agilent GC-MS

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Multifunctional Autosampler AOC-6000 C146-E272A

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Choices, choices, choices... Which sequence database? Which modifications? What mass tolerance?

TECHNICAL BULLETIN. ProteoMass Peptide & Protein MALDI-MS Calibration Kit. Catalog Number MSCAL1 Store at Room Temperature

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

How To Use Gc-Ms

Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes

How To Test For Contamination In Large Volume Water

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

Transcription:

Liquid Chromatograph Mass Spectrometer LCMS-IT-TF C146-E093D

LCMS-IT-TF High-Speed Liquid Chromatograph Mass Spectrometer LCMS-IT-TF A significantly advanced MS detector enabling LC/MS n high-precision mass analysis High speed and high precision in MS n measurement can provide researchers with a host of new possibilities.

High Resolution & High Precision in MS n measurement The stable, high-resolution spectra achieved throughout a wide mass range and high-precision MS n data are derived from the DSR: Dual-Stage Reflectron (*1) and the use of BIE: Ballistic Ion Extraction (*2). These instrument advances can strongly assist in the use of MS for predicting accurate structural details. High Throughput Increased amounts of information are obtained for each measurement, enabling much higher reliability in structural analysis. High-throughput analysis can be realized with the world s best performance hybrid MS used for structural analysis in terms of high-speed mass spectrum measurement and high-speed ion polarity switching. High Sensitivity High-sensitivity detection of low concentration samples is derived through the use of Compressed Ion Injection (CII) within the ion optics (*3), allowing for the ions to be placed efficiently into the ion trap. *1 Patent US6384410, US6803564 and others *2 Patent US6380666 and others *3 Patent US6700116 and others Contents P 04 - riginal and Advanced Technology P 06 - High-Speed and High-Precision MS n Measurement P 08 - Basic Performance Supporting High-Quality Data P 10 - Intelligent Auto MS n Function P 12 - Software to Accelarate Data Analysis

riginal and Advanced Technology What is the IT-TF? There are several types of LC/MS instruments in the market currently. The single quadrupole and triple quadrupole instruments are primarily used for quantitative analysis, while the ion trap, LC-TF and Qq-TF instruments are primarily used for qualitative analysis. Triple quadrupoles are excellent instruments for quantitative analysis, although they falter in comparison to other types of mass spectrometers in terms of mass accuracy and resolution. Ion traps excel in structural analysis due to their ability to perform MS n ; however, the mass accuracy and resolution, like with a triple quadrupole MS, are limited. n the other hand, the Qq-TF fea- tures excellent resolution and mass accuracy compared to the above-mentioned types of instruments. They do exhibit a downside in that it is not possible for Qq-TF instruments to perform MS 3 or greater as their construction does not support MS n. Shimadzu developed a new type of hybrid mass spectrometer, the LCMS-IT-TF, which possesses both the MS n ability of an ion trap and the excellent resolution and mass accuracy of a TF. The LCMS-IT-TF opens new doors to the prediction of elemental composition and structural analysis. Compressed Ion Introduction (CII ) The ion optical system used in the LCMS-IT-TF leads to a novel ion introduction method referred to as Compressed Ion Introduction or CII, where the combination of the skimmer, octopole and first lens converts the continuous stream of ions into pulses for introduction into the ion trap. This method makes it possible to control the accumulation of ions before they are introduced into the ion trap, allowing the RF to be applied to the ring electrode at the instant that all of the CII-accumulated ions enter the ion trap. This new method of controlling the ion trap, which is quite different from a traditional ion trap, is adopted for the LCMS-IT-TF. The development of this CII effectively couples the LC system to the MS and enables a dramatic improvement over the previously deficient ion capture rate of the ion trap, thereby increasing sensitivity. Lens 1 (+60 V) Lens 1 (+60 V) Lens 1 (-80 V) V V V Skimmer (+8 V) "pen" Skimmer (-30 V) "Closed" Skimmer (-30 V) "Closed" Ion trap Skimmer Lens 1 Skimmer Lens 1 Skimmer Lens 1 Ion trap 4

CDL DQarray ctopole lens Ion trap Flight tube with temperature control Atmospheric Ionization Probe Skimmer Lens Detector Dual-Stage Reflectron In the LCMS-IT-TF, rather than simply combining the existing technologies of the QIT (Quadrupole Ion Trap) mass spectrometer and an oatf (rthogonal Acceleration Time of Flight) mass spectrometer, the QIT and TF are arranged linearly in a unique construction. This construction offsets the disadvantages of slow measurement speed, ion capture rate and trap saturation associated with the ion trap, while allowing the advantages of the ion trap and TF to be fully demonstrated. Abundant qualitative information can be obtained within a limited HPLC peak elution time. High-Efficiency Collision-Induced Dissociation using Argon Pulsed Ar CID In the LCMS-IT-TF, Ar gas is introduced into the trap via a pulse valve to perform cleaning just prior to conducting CID (Collision-Induced Dissociation). This introduction of Ar has resulted extremely efficient CID. 60000 50000 without Pulsed Argon m/z 1110 (Precursor ions) m/z 838 (Product ions) 60000 50000 with Pulsed Argon m/z 1110 (Precursor ions) m/z 838 (Product ions) Signal intensity 40000 30000 20000 Signal intensity 40000 30000 20000 10000 10000 0 0 0.2 0.4 0.6 0.8 1 0 0 0.2 0.4 0.6 0.8 1 CID waveform amplitude (V) CID waveform amplitude (V) Sample: atfa Without pulsed Ar introduction, product ion intensity noticeably decreases as the CID energy is increased. n the other hand, with pulsed Ar introduction, the product ion intensity remains unchanged even as the CID energy increases. In the case of traditonal ion traps, it is necessary to adjust the CID energy depending on the m/z value selected; however, with the LCMS-IT-TF, equipped with the unique technology of pulsed Ar CID, MS n measurement of compounds having various m/z s can be performed under a single set of CID conditions. Addressing Sharp Chromatographic Peaks BIE [Ballistic Ion Extraction] In the LCMS-IT-TF, faster spectrum measurement has been achieved by accelerating the ions from the ion trap to the TF using a new technology termed Ballistic Ion Extraction (BIE), which enables high-throughput analysis. BIE is an ion accelerating method to inject ions into the TF instantly by applying a high voltage with opposite polarity to the end-caps and lowering the ring electrode RF voltage to 0V. BIE aids in lowering the spatial distribution of the ions as they enter the TF region. +kv 0 V -kv Reflectron LCMS-IT-TF Liquid Chromatograph Mass Spectrometer 5

High-Speed and High-Accuracy MS n Measurement The LCMS-IT-TF is intended to strongly assist in the identification of target compounds by using high-speed/high-accuracy MS n data in R&D fields such as impurity analysis, metabolic profiling and biomarker research. H H H H ( 10,000,000) H H H H H3C H H3C 1.00 aloxone altrexone 6-beta-naltrexol Buprenorphine MS 1 scan points Half Height Peak Width: 1.2 sec 0.50 2.4 4.8 7.2 sec 1 min+ 0.00 0.0 0.5 1.0 1.5 2.0 min MS 1 [M+H] + Expected 342.1705 H 342.1691 4.09 ppm H C20H234 100 150 200 250 300 350 400 450 m/z MS 2 [342-H2] + Expected 324.1600 324.1605-1.54 ppm 100 150 200 250 300 350 400 450 m/z MS 3 [324-C4H6] + Expected 270.1130 270.1137-2.59 ppm 100 150 200 250 300 350 400 450 m/z External Standard Method The data above shows the analysis of four compounds within 2.0 minutes. The Auto MS n function makes it possible to obtain highly accurate MS n data via an external standard, taking advantage of high-speed mass spectrum measurement performance. Column Mobile phase A Mobile phase B Time program Flow speed Injection volume Column oven temperature : : : : : : : Shim-pack XR-DS (2.0 30 mm, 2.2 µm) 0.1 % formic acid 0.1 % formic acid in methanol 4 % B (0 min) 100 % B (0.5 min) 4 % B (0.51 2.00 min) 0.5 ml/min 5 µl (1 ng/µl) 50 C 6

Ion fragmentation is very useful in structural analysis. The LCMS-IT- TF has a unique design in that it connects an ion trap with a TF and provides high-precision mass information for either MS or MS n. This makes it possible to perform highly reliable structural analysis. H3C R S C19H2133S R MS 1 [M+H] + Expected 372.1376 372.1365-2.96 ppm 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 m/z MS 2 [372--S2Me] + Expected 293.1523 293.1511-4.09 ppm -78.9854 Da (Expected 78.9854) 0.0 mda 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 m/z MS 3 [293--C2H3] + Expected 250.1339 250.1331-3.20 ppm -43.0180 Da (Expected 43.0184) -0.4 mda 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 m/z MS 4 [250--C7H9] + Expected 143.0604 143.0606 1.40 ppm -107.0725 Da (Expected 107.0735) -1.0 mda 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 450.0 m/z External Standard Method The above examples show that the low-mass product ions can be analyzed precisely and the new compounds can be identified by MS n measurement. Sample provided by: AstraZeneca (UK) Dr. Richard Gallagher LCMS-IT-TF Liquid Chromatograph Mass Spectrometer 7

Basic Performance Supporting High-Quality Data Compatibility of High Sensitivity and Mass Accuracy 100 attomol of Fibrinopeptide A MS 1 768.8472 M.W. 1535.6852 ADSGEGDFLA EGGGVR Ion Measured Expected Error (ppm) [M+2H] 2 + 768.8472 768.8506-4.4 760.0 770.0 780.0 790.0 m/z Ion y4 Measured 388.2332 Expected 388.2308 Error (ppm) 6.2 y5 445.2506 445.2523-3.8 y6 574.3000 574.2949 8.9 MS 2 b7 y 7 y7 y8 645.3255 758.4197 645.3320 758.4161-10.1 4.7 y 5 b9 y9 905.4801 905.4845-4.9 y 6 y11 1077.5442 1077.5329 10.5 y 4 y 8 y 9 y 11 b7 632.2098 632.2164-10.4 400 600 800 1000 1200 1400 m/z b9 892.3636 892.3688-5.8 Extended Stability in Mass Accuracy The high-accuracy temperature control mechanism of the flight tube, the localized ion due to BIE from the QIT, and the effective 10-bit high-speed transient recorder enable extremely stable mass accuracy using the external standard method. Due to labor-intensive work required when using an internal standard for LC/MS anal- ysis, it is extremely important to achieve stable high mass accuracy over a wide mass range using an external standard. In the LCMS-IT- TF, TF mass calibration can be automatically performed to maintain the stability for an extended period of time. 1064.820 1064.818 1064.816 1064.814 1064.812 1064.810 1064.808 1064.806 1064.804 1064.802 1064.800 m/z External Standard Method (m/z 1064: atfa) 2 ppm 0 200 400 600 800 1000 1200 1400 1600 1800 min 8

High-Speed Ion Polarity Switching Mode [up to 2.5 Hz] High-Speed Ion Polarity Switching can be especially useful when it cannot be judged whether samples will be detected as positive or negative ions. The LCMS-IT-TF utilizes a newly developed, highly accurate and stable power supply as well as a newly developed high-voltage switch that allows for polarity switching in only 0.1 sec or less (necessary for the sharp HPLC peaks available with the advances in high-speed chromatography). The maximum rate for polarity switching is 2.5 Hz, which allows for a pair of positive and negative ion MS spectra to be obtained 2.5 times per second. Voltage change monitored with an oscilloscope 10 8 3 4 2 Time (sec) 0-0.6-0.5-0.4-0.3-0.2-0.1 0 0.1 0.2 0.3 0.4 0.5 0.6-2 Voltage (kv) -4-6 -8-10 High-Speed Ion Polarity Switching Mode Measurement Example Total Ion Chromatogram 2.5 Inten.( 10,000,000) Positive/egative Sum TIC Positive ion TIC egative Ion TIC Sample Column Mobile phase Flow rate : glycosylceramide (C16,18,20,22,23,24:0-d18:1), (C24:1-d18:1) : Imtakt Cadenza CD-C18 : 5 mm Acetic acid in methanol : 0.2 ml/min 0.0 0.0 2.5 5.0 7.5 min Positive Ion Mass Chromatogram Inten. ( 10,000,000) 2.5 722.55 832.66 750.58 806.65 906.27 820.66 980.29 834.68 722.5527 2.75ppm [M+a] + Expected 722.5547 500 1000 1500 m/z 0.0 0.0 2.5 5.0 7.5 min egative Ion Mass Chromatogram Inten. ( 10,000,000) 5.0 812.55 896.65 840.58 910.66 868.62 924.68 922.66 812.5475 3.02ppm [M+TFA-H] - Expected 812.5497 500 1000 1500 m/z 0.0 0.0 2.5 5.0 7.5 min Provided by RIKE LCMS-IT-TF Liquid Chromatograph Mass Spectrometer 9

Intelligent Auto MS n Function What is the Auto MS n Function? Samples cannot be recaptured once injected for LC/MS analysis; therefore, it is vital that instruments can automatically select the appropriate precursor ions. With the LCMS-IT-TF, a variety of precursor ion selection criteria, such as the selection of ions in order of intensity or m/z is available, in addition to intelligent automatic precursor selection, such as a monoisotopic peak selector and chargestate filtering. Main Functions for Precursor Ion Selection MS 1 TIC Threshold MS 1 Threshold Selection in the order of intensity or m/z Charge state filter Monoisotopic filter Exclusion ion (Automatic exclusion) Pair peak selection Preference Ion Selection eutral Loss Survey m/z Selecting precursor ions automatically and measuring MS 2 MS 2 m/z m/z Principles of eutral Loss Survey MS 3 measurements are automatically performed if the specified neutral loss is observed in the MS 2 spectrum. With the eutral Loss Survey, only the target ions are measured in MS 3, enabling one to obtain desired information effectively without loss of time. As detailed information about target ions is obtained using the neutral loss survey function, it can become a powerful tool for supporting the identification of compounds (e.g., phase II metabolites for drug discovery research). Judgment of neutral loss MS 2 [Ma-m] + Ma + MS 3 [Ma-m] + Setting neutral loss m MS 1 Mb + Ma + m m/z MS 2 measurement with Ma + as precursor ion m/z MS 3 measurement with [Ma-m] + as precursor ion m/z MS 2 [Mb-n] + Mb + n ot going on MS 3 measurement m/z MS 2 measurement with Mb + as precursor ion 10

Examples Highlighting the eutral Loss Survey Function The combination of the neutral loss survey and MS 3 measurement provides accurate mass information that can lead to highly reliable structural analyses of phospholipids. MS 1 measurement phospholipid CH2--P (H) --X MS 2 measurement : Polar radical-specific neutral loss (L) Polar radical information CH --C-R2 CH2--C-R1 MS 3 measurement : Lipid chain information Setting PS (Polar radical X : serine) - specific L (87 Da) and performing the neutral loss survey MS 1 [M-H] - for diacyl 40:5 PS Expected 836.5442 [M+CH3C] - for diacyl 36:6 PC Expected 836.5442 PS or PC? 810.5225 834.5237 836.5431-1.31 ppm 100 200 300 400 500 600 700 800 900 m/z PC : Phosphatidilcholine PS : Phosphatidilserine PA : Phosphatidic acid FA : Fatty acid R1 R2 PA-H P - loss of 87.0320 Da : C2H2 (H2)CH H2 CH MS 2 of m/z 836.5 [M-H] - for diacyl 40:5 PA Expected 749.5121 749.5150-3.87 ppm L of 87 Da 100 200 300 400 500 600 700 800 900 m/z MS 3 of m/z 749.5 283.2636-0.35 ppm 419.2550-3.10 ppm [M-H] - for acyl 18:0 FA Expected 283.2637 [M-H] - for acyl 18:0 cyclicpa Expected 419.2563 100 200 300 400 500 600 700 800 900 m/z Using neutral loss survey, diacyl 18:0 22:5 PCs in the lipid mixture were easily identified. Mass accuracy of less than 5 ppm was obtained in MS 1 through MS 3 using an external standard. Detection of PS-specific L: Polar radical information Performing MS 3 measurement of precursor ions at m/z 749 by neutral loss survey R1 +H 1-lysoPA--H -H2 FA--H P FA--H H - R2 +H -H2 2-lysoPA--H 1-cyclicPA--H 2-cyclicPA--H MS 3 measurement: Lipid chain information Sample : lipid mixture from rat liver Column : Si column (1.0 10 mm) Mobile phase : gradient of acetonitrile (A) and methanol (B) (including 0.3 % formic acid and 0.1 % ammonia water in (A) and (B) each) LCMS-IT-TF Liquid Chromatograph Mass Spectrometer 11

Software to Accelerate Data Analysis Composition Prediction Software (ptional product) Effectiveness of Accurate MS n In composition prediction, target constituents having a small mass and high mass accuracy associated with their measured values, provide fewer numbers of candidates and greater prediction reliability. When using MS 2 data with the Composition Prediction Software, formula prediction starts with the product ion having the smallest mass, and uses that result in the effective prediction of the parent ion by reducing the number of candidates. Accurate MS n Analysis umber of Candidates Mass decreases Candidates decrease exponentially MS n MS 2 MS 1 Mass C 17H 26 2 5S+H + (m/z 371.1641) Composition Prediction Example MS 1 50 371.1654 MS 2 of m/z 371.1 H2S- H 6-hydroxy-5-methoxy-diisopropyltryptamine-sulfate 372.1676 373.1664 371.4059 371.8783 371.0 371.5 372.0 372.5 373.0 373.5 374.0 m/z 158.0610 190.0848 291.2090 270.0443 100 150 200 250 300 350 400 450 m/z H3C CH (CH3)2 CH (CH3)2 Take, for example, the case of predicting the elemental composition of the ion at m/z 371.1645. The correct composition is C17H2625S+H + (m/z 371.1641). The composition prediction procedure is as follows: (1) Composition Calculated from Mass When simply calculating the composition only from the mass value, the proper composition is ranked fifth. (1) Composition Calculated from Mass (2) Using Isotopic Pattern (3) MS n Spectral Filtering # 1 2 3 4 5 6 7 8 9 10 11 12 Formula C18 H22 6 S C10 H18 12 4 C25 H22 3 C13 H26 2 10 C17 H26 2 5 S C9 H22 8 8 C6 H26 8 8 S C14 H22 6 6 C22 H26 3 S C8 H26 4 12 C7 H22 12 4 S C21 H18 6 # 1 2 3 4 5 6 7 8 9 10 11 12 Formula C17 H26 2 5 S C10 H18 12 4 C18 H22 6 S C9 H22 8 8 C13 H26 2 10 C25 H22 3 C6 H26 8 8 S C8 H26 4 12 C14 H22 6 6 C22 H26 3 S C21 H18 6 C7 H22 12 4 S # 1 2 Formula C17 H26 2 5 S C6 H26 8 8 S (2) Using lsotopic Pattern When additionally comparing and ranking the isotopic patterns, the correct composition is ranked first. (3) MS n Spectral Filtering Finally, taking into account the MS n data enables 12 candidates to be reduced to 2, as shown in the table. In this way, using the isotopic patterns enables the correct formula to achieve a higher ranking. Furthermore, using MS n data enables a reduction in the number of candidates. 12

MetID Solution Metabolite Structural Analysis Software (ptional product) Comprehensive Metabolite Detection and Structure Prediction Using Accurate Mass Information from HPLC and nline MS n This software compares data from an unmetabolized control sample and a metabolized target sample to detect metabolites, and the built-in Composition Prediction Software predicts the composition. Peaks existing in the target sample data but not in the control sample data are possible metabolites. Metabolite candidates are accurately selected through comparison of their isotopic patterns and these are used to support identification. Comprehensive metabolite candidate information can also be acquired for metabolites with an unknown pathway by exploiting the high-speed data measuring capacity of the LCMS-IT-TF to conduct MS n measurements of accurate mass information with online HPLC, and then applying unique multivariate analysis. Moreover, an isotope filter chromatogram (IFC) function is available to extract required data from the huge amount of information. IFC is useful for the detection of compounds labeled with stable isotopes or radio isotopes and assists with the detection of reactive metabolites. More generally, it is also effective for highly reliable detection of compounds containing elements with characteristic isotopic patterns, such as chlorine or bromine. The MetID Solution approach of applying multivariate analysis to exhaustively detect compounds with a structure resembling the major components is also extremely effective for the efficient analysis of impurities and natural products in synthetic compounds. pen Access Software pen Solution ComponentID (ptional product) Fully Automated, from Precision Mass Spectrometry Measurements to Formula Prediction and Report Creation pen Solution ComponentID is a software tool developed in response to customer requests for open access software that allows performing precision mass spec- Log into pen Solution ComponentID. Specify the number of vials and set the vials in their specified positions Click the [START] button. trometry measurements using LCMS-IT- TF, without relying on specialized operators. It enables running analyses in only 3 steps. After measurements are finished, it automatically sends a report of formula prediction results to the email address of PDF report the user currently logged in. End analysis. Send e-mail. LCMS-IT-TF Liquid Chromatograph Mass Spectrometer 13

Software to Accelerate Data Analysis Data Processing Software for Profiling Profiling Solution Ver. 1.0 (ptional product) Creates Data Array by Extracting Peaks from Multiple Data Files This software automatically detects peaks in multiple data files analyzed using the LCMS-IT-TF, performs any additional operations, such as listing peak retention times, as necessary, and then tabulates results. This step of creating a table from measurement data is a critical step that can determine the success or failure of metabolomics or differential analysis for food products, cosmetics, or other fields. riginal data can be easily referenced from the table, which helps to ensure highly reliable data analysis. Tabulated data can be analyzed using commercial statistical analysis software, which enables utilizing a wide variety of analytical techniques. This is especially useful for metabolomics or impurities profiling applications using LCMS-IT-TF, which enables high-speed analysis. Analytical instrument File 1 File 2 File 3 File 4 m/z, retention time set Multiple data Data table Multivariate analysis software Automatic Extraction and Display of Peaks from a Large umber of Data Files Simply drag and drop multiple measurement data files and click the run button to output the tabulated content of data files. This tabulated data can be used as data for multivariate analysis. Table of peaks extracted from each data file Chromatograms and mass spectra can be displayed for all data. perations (division, integration, logic operations) and filtering functions for the signal intensities are provided to allow comparison and overview of the data. List of data files TIC, XIC, and spectrum display area Mass Spectra Display XIC Display 14

Protein Analysis Software (ptional product) By combining LCMSsolution with the newest addition to the solutions suite, Protein Analysis, the LCMS-IT-TF can be set up for automated protein identification experiments. Protein Analysis features the same user-friendly interface as LCMSsolution. By setting the peak-list generation and database search parameters in the protein method, the process can be automated from analysis to protein identification. The identification results can be viewed directly from the Protein Analysis software, enabling easy data management. Moreover, the parameters can be easily changed for follow-up searches. The valuable time saved with the efficiency of this software makes it indispensable for protein analysis. A screen capture of the Protein Analysis software The MS data from the Protein Analysis software data file and the Mascot search results can be viewed together. Data Explorer Chromatogram Precursor ion information (Charge state and retention time) MS Spectrum Chromatogram preview Measurement Example (BSA Tryptic digest 50 fmol) As a result of the Mascot search, BSA s score is 1180 and the o.1 ranking protein hit. Furthermore, all of the peptide masses are reported to be within the error range of 4 ppm or less in the identification results (data collected using an external standard). This data exemplifies the high-quality measurement obtainable with the high-accuracy LCMS-IT-TF. LCMS-IT-TF Liquid Chromatograph Mass Spectrometer 15

Series Semi-micron high-pressure liquid chromatography front end system + LCMS-IT-TF The LCMS-IT-TF has been awarded the R&D 100 chosen by the U.S. technology information magazine R&D LCMS-IT-TF Installation View 57 cm 26 cm 26 cm 26 cm 168.5 cm Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. www.shimadzu.com/an/ For Research Use nly. ot for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2012 Printed in Japan 3655-04203-50AS