WAGO-I/O-SYSTEM. Using library WagoLibMSSQL_03.lib in CoDeSys 2.3 for interface to Microsoft SQL Server 200x. Application Note



Similar documents
Application Note. WAGO EtherNet/IP Communications with a CompactLogix PLC Using Explicit Messaging. A500620e, English Version: 1.0.

Remote Connection to a WAGO using a High-Speed Internet connection Application note

Using library WagoLibMySQL to communicate with MySQL-Databases Application note

Ethernet/IP Comms between a WAGO and a Mettler Toledo JAGXTREME Terminal Application note

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

Accessing EtherNet/IP Network Variables in a WAGO with a ControlLogix PLC Application note

Using the SysLibFile.lib and the WagoLibFtp.lib for file access Application note

Ethernet PFC Sending Application note

Transmitting s in a local network with a WAGO CONTROLLER Application note

Application note. A103202, English Version 1.0.1

Connect Ethernet-Controller to TO-PASS web portal via GPRS-Router Application note

WAGO-I/O-SYSTEM in ABB robot control systems Application note

WAGO Software CODESYS Library WagoLibDiagnosticIDs.lib for accessing the internal diagnostics protocol

Immotec Systems, Inc. SQL Server 2005 Installation Document

Configuration a Profibus-DP node using Step7 and WAGO-I/O components Application note

WAGO PFC 750-8xx Interface to Horner HMI Application note

Transmitting s with the WAGO IPC Application note

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

Install MS SQL Server 2012 Express Edition

Transmitting s with the library "WagoLibMail_02.lib" Application note

Installation Guide for Microsoft SQL Server 2008 R2 Express. October 2011 (GUIDE 1)

1. CONFIGURING REMOTE ACCESS TO SQL SERVER EXPRESS

EtherNet/IP communications between a WAGO PFC and a SICK IVC-2D Camera Application note

NetSupport DNA Configuration of Microsoft SQL Server Express

Setting up an MS SQL Server for IGSS

Print Audit 6 - SQL Server 2005 Express Edition

Project management - integrated into Outlook

General Tips: Page 1 of 20. By Khaled Elshaer.

The Project Management Software for Outlook, Web and Smartphone

NetSupport DNA Configuration of Microsoft SQL Server Express

QUANTIFY INSTALLATION GUIDE

Sending / receiving SMS using a GSM modem Application note

SQL Server 2008 R2 Express Edition Installation Guide

Setting Up ALERE with Client/Server Data

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

SQL EXPRESS INSTALLATION...

Cloud Services ADM. Agent Deployment Guide

WAGO PFC as a MODBUS MASTER Application note

Installing LearningBay Enterprise Part 2

USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. August 2014 Phone: Publication: , Rev. C

BillQuick Installation Guide for Microsoft SQL Server 2005 Express Edition

Active Directory Management. Agent Deployment Guide

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

Network DK2 DESkey Installation Guide

Installing SQL Express. For CribMaster 9.2 and Later

SMS Database System Quick Start. [Version 1.0.3]

Microsoft SQL Server 2008 R2 (64-bit) Standard Edition Installation Guide

Connecting to SQL server

Omgeo OASYS Workstation Installation Guide. Version 6.4 December 13, 2011

Moving the TRITON Reporting Databases

Microsoft SQL Server 2008 R2 Express Edition with Advanced Services Installation Guide

Sage 200 Web Time & Expenses Guide

This manual will also describe how to get Photo Supreme SQLServer up and running with an existing instance of SQLServer.

Using SQL Server Management Studio

Installation Instruction STATISTICA Enterprise Small Business

Microsoft SQL Server Installation Guide

GETTING STARTED WITH SQL SERVER

Portions of this product were created using LEADTOOLS LEAD Technologies, Inc. ALL RIGHTS RESERVED.

Dell Statistica Statistica Enterprise Installation Instructions

EntroWatch - Software Installation Troubleshooting Guide

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents

UNICORN 7.0. Administration and Technical Manual

KonyOne Server Prerequisites _ MS SQL Server

Accounting Manager. User Guide A31003-P1030-U

Server Installation Guide ZENworks Patch Management 6.4 SP2

UNICORN 6.4. Administration and Technical Manual

SiteCount v2.0 Revised: 10/30/2009

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Ingenious Testcraft Technical Documentation Installation Guide

NovaBACKUP xsp Version 15.0 Upgrade Guide

for Networks Installation Guide for the application on the server July 2014 (GUIDE 2) Lucid Rapid Version 6.05-N and later

CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES

FieldIT Limited FieldIT CRM. Installation Manual v1.3.i3 (Enterprise Install)

Upgrade ProTracker Advantage Access database to a SQL database

Microsoft SQL Server 2008 R2 Express Edition with Advanced Services Installation Guide

VMware vcenter Discovered Machines Import Tool User's Guide Version for vcenter Configuration Manager 5.3

Upgrading from MSDE to SQL Server 2005 Express Edition with Advanced Services SP2

Table of Contents. CHAPTER 1 About This Guide CHAPTER 2 Introduction CHAPTER 3 Database Backup and Restoration... 15

ScriptLogic File System Auditor User Guide

Virtual CD v10. Network Management Server Manual. H+H Software GmbH

Upgrading to Document Manager 2.7

Interworks. Interworks Cloud Platform Installation Guide

Server Installation, Administration and Integration Guide

ManageEngine IT360. Professional Edition Installation Guide.

TSM Studio Server User Guide

Bosch ReadykeyPRO Unlimited Installation Guide, product version 6.5. This guide is item number DOC , revision 2.029, May 2012.

INSTALLING MICROSOFT SQL SERVER AND CONFIGURING REPORTING SERVICES

TecLocal 4.0 MultiUser Database

Creating a New Database and a Table Owner in SQL Server 2005 for exchange@pam

Download and Installation of MS SQL Server

Introduction and Overview

EPSON Scan Server & EPSON TWAIN Pro Network

Knowledge Base Article: Article 218 Revision 2 How to connect BAI to a Remote SQL Server Database?

Backup Server DOC-OEMSPP-S/6-BUS-EN

PigCHAMP Knowledge Software. Enterprise Edition Installation Guide

How To Set Up Total Recall Web On A Microsoft Memorybook (For A Microtron)

Portions of this product were created using LEADTOOLS LEAD Technologies, Inc. ALL RIGHTS RESERVED.

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Transcription:

Application Note Using library WagoLibMSSQL_03.lib in CoDeSys 2.3 for interface to Microsoft SQL Server 200x WAGO-I/O-SYSTEM a302510, English Version: 1.0.0

2 Impressum 2012 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 0 Fax: +49 (0) 571/8 87 1 69 E-Mail: Web: info@wago.com http://www.wago.com Technical Support Phone: +49 (0) 571/8 87 7 77 Fax: +49 (0) 571/8 87 87 77 E-Mail: tcba@wago.com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation. However, as errors can never be fully excluded, we always appreciate any information or suggestions for improving the documentation. We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally protected by trademark or patent.

Table of Contents 3 Table of Contents 1 Important Notes... 4 1.1 Legal Principles... 4 1.1.1 Subject to Changes... 4 1.1.2 Copyright... 4 1.1.3 Personnel Qualification... 4 1.1.4 Intended Use... 4 1.2 Scope of Validity... 5 1.3 Number Notation... 5 1.4 Font Conventions... 5 2 Description... 6 2.1 Components... 6 3 Setup database... 7 3.1 Enable TCP/IP... 7 3.2 Enable SQL Server Authentication... 9 3.3 Enable remote connection... 12 3.4 Enable or create database account sa... 14 3.5 Create database testdb... 15 4 WagoLibMSSQL03_Example01.pro... 17

4 Important Notes 1 Important Notes To ensure quick installation and start-up of the units, we strongly recommend that the following information and explanations are carefully read and adhered to. 1.1 Legal Principles 1.1.1 Subject to Changes WAGO Kontakttechnik GmbH & Co. KG reserves the right to provide for any alterations or modifications that serve to increase the efficiency of technical progress. WAGO Kontakttechnik GmbH & Co. KG owns all rights arising from the granting of patents or from the legal protection of utility patents. Third-party products are always mentioned without any reference to patent rights. Thus, the existence of such rights cannot be excluded. 1.1.2 Copyright This Manual, including all figures and illustrations, is copyright-protected. Any further use of this Manual by third parties that violate pertinent copyright provisions is prohibited. Reproduction, translation, electronic and phototechnical filing/archiving (e.g., photocopying) as well as any amendments require the written consent of WAGO Kontakttechnik GmbH & Co. KG, Minden, Germany. Non-observance will involve the right to assert damage claims. 1.1.3 Personnel Qualification The use of the product detailed in this document is exclusively geared to specialists having qualifications in PLC programming, electrical specialists or persons instructed by electrical specialists who are also familiar with the valid standards. WAGO Kontakttechnik GmbH & Co. KG declines any liability resulting from improper action and damage to WAGO products and third party products due to non-observance of the information contained in this document. 1.1.4 Intended Use For each individual application, the components are supplied from the factory with a dedicated hardware and software configuration. Modifications are only admitted within the framework of the possibilities documented in this document. All other changes to the hardware and/or software and the non-conforming use of the components entail the exclusion of liability on part of WAGO Kontakttechnik GmbH & Co. KG. Please direct any requirements pertaining to a modified and/or new hardware or software configuration directly to WAGO Kontakttechnik GmbH & Co. KG.

Important Notes 5 1.2 Scope of Validity This application note is based on the stated hardware and software of the specific manufacturer as well as the associated documentation. This application note is therefore only valid for the described installation. New hardware and software versions may need to be handled differently. Please note the detailed description in the specific manuals. 1.3 Number Notation Table 1: Number Notation Number code Example Note Decimal 100 Normal notation Hexadecimal 0x64 C notation Binary '100' '0110.0100' In quotation marks, nibble separated with dots (.) 1.4 Font Conventions Table 2: Font Conventions Font type Indicates italic Names of paths and data files are marked in italic-type. e.g.: C:\Programme\WAGO-I/O-CHECK Menu Menu items are marked in bold letters. e.g.: Save > A greater-than sign between two names means the selection of a menu item from a menu. e.g.: File > New Input Designation of input or optional fields are marked in bold letters, e.g.: Start of measurement range Value Input or selective values are marked in inverted commas. e.g.: Enter the value 4 ma under Start of measurement range. [Button] Pushbuttons in dialog boxes are marked with bold letters in square brackets. e.g.: [Input] [Key] Keys are marked with bold letters in square brackets. e.g.: [F5]

6 Description 2 Description Library WagoLibMSSQL_03.lib provide function blocks for accessing Microsoft databases for executing SQL-Statements. The WagoLibMSSQL_03.lib library will work with any WAGO Ethernet controller and is based on the SysLibSockets.lib system library. It is expected that the person using this library has a solid base knowledge of CoDeSys and the IEC 61131-3 standard. The configuration of Microsoft SQL Server takes a little time, for this application we used Microsoft SQL Server Management Studio Express with SQL Server Configuration Manager both freely available from the Microsoft website. This application note covers those steps as well as some of the more common errors that could occur from an incorrect set-up as well as an example of how to use the library in an application. 2.1 Components Table 3: Components Supplier Pieces Name Item No. WAGO 1 Programmable Fieldbus Controller 750-8xx WAGO 1 End Module 750-600 WAGO 1 WAGO-I/O-PRO CAA 759-333 Microsoft 1 SQL Server 2005(EXPRESS) Microsoft 1 SQL Server 2008(EXPRESS) Microsoft 1 SQL Server Management Studio Express Microsoft 1 SQL Server Configuration Manager Trademarks: All terms mentioned in this document that are known to be trademarks or service marks have been appropriately capitalized. Use of a term in this document should not be regarded as affecting the validity of any trademark or service mark. Microsoft is a registered trademark of Microsoft Corporation. SQL Server is a trademark of Microsoft Corporation.

Setup database 7 3 Setup database Follow the online guide on Microsoft s website to download and install Microsoft SQL Server Management Studio Express Edition and all other relevant software (Microsoft Core XML Services (MSXML) 6.0 and Microsoft.NET Framework 2.0.). These are available on the Microsoft web site. 3.1 Enable TCP/IP After installation TCP/IP driver is disabled by default and have to be enabled manually. Enable TCP/IP access to database by selecting Start>Programs>Microsoft SQL Server 2005> Configuration Tools> SQL Server Configuration Manager. In the configuration manager expand SQL Server 2005 Network Configuration on the left of the window and then select Protocols for SQLEXPRESS Check minimum system specification on Microsoft s website for the SQL Server package. This has been tested with SQL Express 2005 and 2008. For more information on SQL Server components beyond this application note, please consult the Microsoft web site.

8 Setup database If TCP/IP isn t enabled right click on it and select Enable Double click on TCP/IP and expand register card IPAll Edit the TCP Port to the TDS default port 1433. The port number is also used as input parameter of the MSSQL_Login function block and can be changed to meet your IT requirements.

Setup database 9 3.2 Enable SQL Server Authentication SQL Server provides two different authentication methods: - Windows-Authentication (Enabled by default) - SQL Server Authentication (Disabled by default). Libraries function block MSSQL_Login utilizes SQL Server Authentication, where database user and password are input parameters who must match with the one stored inside the database self. Open Microsoft SQL Server Management Studio Express. Select Database Engine, and Windows Authentication as shown in the screenshot below. For Server name: select <Browse for more >. In the new window, select the Network Servers tab and wait a few seconds while it retrieves data. Eventually you will see the Database Engine displayed only, expand this and select the SQLEXPRESS Server.

10 Setup database Click OK to connect to the Server. Now in the object explorer section, right click on the server and select Properties from the drop down menu. Choose the Security page and in the Server authentication section select SQL Server and Authentication mode After clicking OK you will be told that you need to restart the SQL Server.

Setup database 11 You can do this in the object explorer section, right click on the server as before but this time select Restart from the menu. Wait for the server to restart, current state are displayed with green or red icon.

12 Setup database 3.3 Enable remote connection Open the SQL Server Service Area Configuration. The following dialog should be displayed Select Surface Area Configuration for Services and Connections Select Remote Connections and then on the right choose 'Local and remote connections' and press button Apply.

Setup database 13 The final bit to check here is in the SQL Server Browser. Select Service and check that Startup type: is set to Automatic.

14 Setup database 3.4 Enable or create database account sa In Microsoft SQL Server Management Studio Express, go to the object explorer and expand the Security folder then the Logins folder. If sa doesn t exist here, right click on the Logins folder and select New Login If it already exists then double click on it. Create the login name sa if it isn t already there. Set the password to wago00 (2 zeros) which is the password used in the CoDeSys example project. You are free to create other user with more or less access rights, just update login creditals in example project.

Setup database 15 3.5 Create database testdb In Microsoft SQL Server Management Studio Express, go to the object explorer and right click the Databases folder. Select New Database and enter testdb as the Database name. Refresh the object explorer then open the newly created testdb folder.

16 Setup database In here right click on the Tables folder and choose New Table Following steps 1 to 3 in the screenshot below After saving this new table the SQL set-up should now be complete. Alternative you can execute attached SQL-Script Create_aTable.sql in Microsoft SQL Server Management Studio Express, to create the table atable in one step. Menu-> File -> Open -> File... or press [Crtl + O] will show File open dialog. Browse to location where Create_aTable.sql stored and open it. Run SQL-CREATE-Statement with Menu -> Query -> Execute. Microsoft SQL Server Management Studio also useful to take a look into current content of a table, just a right click on the table of interest open the background menu. Select Open Table will show table data with the opportunity to modify it. You can also use function block MSSQL_Execute to create databases and tables from your CoDeSys application, because SQL-CREATE-Statements are nothing else then SQL-Statements who do not return result sets, like INSERT, UPDATE, DELETE, DROP, ALTER and so on.

WagoLibMSSQL03_Example01.pro 17 4 WagoLibMSSQL03_Example01.pro Copy library file WagoLibMSSQL_03.lib into folder CoDeSys V2.3\Targets\WAGO\Libraries\Application\ first. The start of this program demonstrates how to connect to a database and then add values to a table named atable in the testdb database. Below is an example of what the MSSQL_Login function block should look like in your application. Function block MSSQL_Login establish the connection to your server. Be sure to match the parameters here to those on your server. To run this change the xconnect variable to TRUE. Verify function blocks output params dierror, sstatus and xconnected that the connection is established. Don t forget to Logout after work is done, otherwise you will waste performance and memory on server machine. Also you can not be shure that a TCP/IP connection is working for days and weeks. To run this change the xdisonnect variable to TRUE.

18 WagoLibMSSQL03_Example01.pro The next thing we will do is inserting some data into the database. There for we need a SQL INSERT statement. What we will do is hard code a few values, these will likely be variables in your application. GETDATE() calls a database function who returns servers local time. Its recommended to build and test your SQL-Statement in the SQL Management Studio prior to coding it to ensure proper syntax. INSERT INTO atable (alongdt, abool, adint, areal, anvarchar) VALUES (GETDATE(), 1, 12345, 1.73, 'Hello world') Because the apostrophe [ ] character in CoDeSys used as STRING-BEGIN and STRING-END identifier, each occurrence within the SQL-Statement have to be escaped by character [ ]. So that final CoDeSys-SQL-Statement looks like below: ssql := 'INSERT INTO atable (alongdt, abool, adint, areal, anvarchar) VALUES GETDATE(), 1, 12345, 1.73, $'Hello world$') ; Take time to find the additional and the escaped apostrophe [ ]. To run this, change the xexec1 variable to TRUE. The xexec1 variable will reset itself upon completion. Again, check dierror and sstatus to make sure the command executed. If you received no errors, this will have inserted a record into your database

WagoLibMSSQL03_Example01.pro 19 Next step is to retrieve data from the database. First we need a SQL-SELECT-Statement, this example will get all data sets from table atable. SELECT * from atable Next, the assqlstatement2 needs to be populated with our query. assqlstatement2[0] := SELECT * from atable ; assqlstatement2[1] := ; (* END OF SQL-Statement*) After the statement is populated, Getting the results from the database from CoDeSys requires a few things more in your application. In the example application we have created two user defined data types, one labelled RowData and the other TableData, where RowData descripes all columns of the table as in IEC-Datatypes. TableData will be filled in the Convert2IEC action of PLC_PRG and hold the query data. To run the query, set xquery2 variable to TRUE. The xquery2 variable will reset itself upon completion. This will send the SQL command to the database and the status will come back at Successful executed and list the number of rows that it returned. Now the Convert2IEC action is run, and this will break apart the binary data from the query into meaningful records. The resulting data set is pictured above. For the example, I edited a couple of the records in the MSSQL Server tool to show they are different

20 WagoLibMSSQL03_Example01.pro It is important to understand that the WagoLibMSSQL_03 has no knowledge about the structure and dataypes of a query result set. There are helper functions written to get the different data types from the MS format and convert them to IEC format (CoDeSys.) So after some error checking the Convert2IEC action comes to converting field 1, and executes the MSSQL_GetDATETIME. If the database you are connected to varies, the changes to this routine happen here where the data is broken up. The routine can be followed with the comments to see where columns 2, 3, 4 and 5 are also converted to their respective data types.

Serie 21 Artikelnummer Artikelbezeichnung [eof]

WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Hansastraße 27 D-32423 Minden Phone: +49/5 71/8 87 0 Fax: +49/5 71/8 87 1 69 E-Mail: info@wago.com Internet: http://www.wago.com