PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet



Similar documents
Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Communicate and view data from meters with one simple device

Access valuable energy and power information from your system

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

scalable data centre energy management solution

Waveguide Access Point WGA631. Product Guide

Electrical Network Management System

Telephone- and leased line modem for industrial applications TD-36

Rack mounted telephone- and leased line modem for industrial applications

Indoor / Outdoor Antenna

Device Log Export ENGLISH

Technology & Evolution

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Modbus Server SAMSUNG Air Conditioners

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Easily connect your switchboards to facility management solutions

T200, PTP/IEEE 1588 Grandmaster Clock and

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Square D Model 6 Motor Control Centers

Power Meter Series 700

IntesisBox KNX Modbus TCP master

IntesisBox Modbus Server Fidelio IP

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

TCP/IP Network Connectivity and ION Meters

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ORION TELECOM NETWORKS INC. T1

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

IntesisBox KNX Modbus RTU master

Broadband Router ESG-103. User s Guide

IntesisBox KNX LG Air Conditioning

IntesisBox Modbus Server SAMSUNG Air Conditioners

1 Serial RS232 to Ethernet Adapter Installation Guide

HWg-STE HWg-STE PoE MANUAL

C24-CAMANL Video Server/Encoder

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

How To Run An Nport I5000A Device Server

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Power quality monitoring and analysis with reliability

Internet-bridge XPort

Power Meter Series 800

EMR. WAN Compact Router for Industrial Ethernet Networks. A secure access to Ethernet industrial networks making use of the public operator networks

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

TK800-Series Industrial GPRS / UMTS / LTE Router

IntesisBox Modbus Server - Mitsubishi Electric G50

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

ACCESS 9340 and 9360 Meter Ethernet Communications Card ETHER

ION Tips and Tricks. Q&A Session PowerLogic ION Users Conference 2009

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

KNX Panasonic Air Conditioners

TSX ETG 1000 Module User's Manual

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Network Management Card. User Manual

Communication Unit 560CMU05 Data sheet

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Network Management Card

EAP N Wall Mount Access Point / WDS AP / Universal Repeater

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

PowerLogic PowerView Software Restricted to Schneider Personnel. POWERLOGIC PowerView Power Monitoring Software Version 2.

Personalise energy solutions

IntesisBox KNX - LON

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Intelligent power sockets IQsocket tm IQSB-PicoIP. makes your life more comfortable. User guide. IQSB-PicoIP documentation v1.0 R1

User Guide. Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário WNA-100. Wireless Network Adapter

Zero-Variable Outdoor Wireless Radio. Datasheet. Models: BM2-Ti, BM5-Ti. Fully Integrated Radio. Weatherproof Aluminum Casing

Simple Electrical Utility Cost Allocation Solutions

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server

Operating Instruction MEW01652 Revision -

Network Management Card. Installation and Quick Start Manual

NMS300 Network Management System

Modbus Communications System for Micrologic A, P, and H Trip Units

TX OPEN RS232/485 module

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

GV-Data Capture V3 Series User's Manual

PowerLogic ION7550 / ION7650

SNMP Web Management. User s Manual For SNMP Web Card/Box

Demo of Data transferring (.CSV Files) from EGX300 to Our local PC/Laptop using- FTP

First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200

EAP300. Long Range Ceiling Mount Access Point PRODUCT OVERVIEW

PowerLogic ION Enterprise 5.6

EZ-View Network Communications Guide

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Network Management Card

Three-phase monitoring relay CM-PFE

AXIS T81B22 DC 30W Midspan

Foxboro Evo Process Automation System

Cisco S380 and Cisco S680 Web Security Appliance

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Cisco TelePresence MSE 8000

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Using IDENT M System T with Modbus/TCP

Cisco TelePresence MSE 8000

Temperature Alert. LAN-based Temperature and Humidity Data Logger

QUICK START GUIDE. Cisco S170 Web Security Appliance. Web Security Appliance

Transcription:

PowerLogic communication devices EGX100 Ethernet gateway EGX300 Integrated gateway-server Technical data sheet 2011

PowerLogic EGX100 Ethernet gateway PE86138 Function The EGX100 serves as an Ethernet gateway for PowerLogic system devices and for any other communicating devices utilising the Modus protocol. The EGX100 gateway offers complete access to status and measurement information provided y the connected devices via PowerLogic software installed on a PC. PowerLogic software compatiility PowerLogic software is recommeded as a user interface ecause they provide access to all status and measurement information. They also prepare summary reports. The EGX100 is compatile with: PowerLogic ION EEM enterprise enery management software PowerLogic ION Enterprise power management software PowerLogic System Manager power management software PowerLogic PowerView power monitoring software PowerLogic EGX100 Architecture PowerLogic software Ethernet Modus TCP/IP EGX100 gateway Modus RS485 serial link Setup Setup via an Ethernet network Once connected to an Ethernet network, the EGX100 gateway can e accessed y a standard internet rowser via its IP address to: specify the IP address, sunet mask and gateway address of the EGX gateway configure the serial port parameters (aud rate, parity, protocol, mode, physical interface and timeout value) create user accounts create or update the list of the connected products with their Modus or PowerLogic communication parameters configure IP filtering to control access to serial devices access Ethernet and serial port diagnostic data update the firmware specify the user language Setup via a serial connection Serial setup is carried out using a PC connected to the EGX100 via an RS232 link. This setup: specifies the IP address, sunet mask and gateway address of the EGX gateway specifies the language used for the setup session Part numers ION6200 PM800 Micrologic Sepam Powerlogic EGX100 Schneider Electric Square D EGX100 EGX100MG EGX100SD 2 Version 7.1 432E4020.indd

PowerLogic EGX100 Ethernet gateway Characteristics Weight EGX100 170g PE86138 Dimensions (HxWxD) Mounting 80.8 x 72 x 65.8 mm Din rail Power-over-Ethernet (PoE) Class 3 Power supply Maximum urden 24 Vdc if not using PoE 4 W Operating temperature -25 to 70ºC Humidity rating 5 to 95% relative humidity (without condensation) at +55ºC Regulatory/standards compliance for electromagenetic interference Emissions (radiated and conducted) EN55022/EN55011/FCC class A Immunity for industrial environments: - electrostatic discharge EN 61000-6-2 PowerLogic EGX100 - radiated RF EN 61000-4-2 - electrical fast transients EN 61000-4-3 - surge EN 61000-4-4 - conducted RF EN 61000-4-5 - power frequency EN 61000-4-6 - magnetic field EN 61000-4-8 Regulatory/standards compliance for safety International (CB scheme) IEC 60950 USA UL508/UL60950 Canada cul (complies with CSA C22.2, no. 60950) Europe EN 60950 Australia/New Zealand AS/NZS25 60950 Serial ports Numer of ports 1 Types of ports RS232 or RS485 (2-wire or 4-wire), depending on settings Maximum aud rate Maximum numer of connected devices Modus RTU/ASCII, PowerLogic (SY/MAX), Jus 38400 or 57600 aud depending on settings 32 (directly) 247 (indirectly) Ethernet port Numer of ports 1 Type of port 10/100 Base TX (802.3af) port HTTP, Modus TCP/IP, FTP, SNMP (MIB II) Installation Din rail mounting 65.8 72 35 57.9 80.8 90.7 45.2 49.5 2.5 68.3 432E4020.indd Version 7.1 3

PowerLogic EGX300 Integrated gateway-server PE86181 Function The EGX300 is an Ethernet-ased device providing a simple transparent interface etween Ethernet-ased networks and field devices. These include meter, monitors, protective relays, trip units, motor controls and other devices that communicate using ModusTCP/IP, Modud, JBUS, or PowerLogic protocol. The EGX300 can form a simple, scalale we-ased monitoring solution providing real-time data views, on-oard data logging/trending, and simple control for field devices. The EGX300 helps provide a system solution that can upgrade to include monitoring software for more advanced data collection, trending, alarm/event management, analysis and other functions. The EGX300 is compatile with: PowerLogic EGX300 PowerLogic ION EEM enterprise energy management software PowerLogic ION Enterprise power management software PowerLogic System Manager power management software PowerLogic PowerView power monitoring software Architecture View real-time data and trend plots through a simple rowser no software needed EGX300 we page Trend plots Data log files Ethernet Modus TCP/IP EGX100 gateway EGX300 integrated gateway-server Pull information into we pages from other PowerLogic gateways (PM8ECC, EGX100) Modus RS485 serial link Features View real-time and historical information and real-time trending from multiple locations via any standard we rowser Automatically detect attached Modus serial devices for easy setup Automatically email, FTP, or HTTP selected logged data to your PC for additional analysis Select the logging intervals and topics you want logged Ensures data and system security through password protection and controlled network access to individual/custom we pages Simplifies installation y receiving control power through the Ethernet cale utilising Power-over-Ethernet and offers the option to utilise 24 Vdc control power Perform simple control reset commands for supported devices (e.g. min/max, accumulated energy, etc.) Log equipment maintenance activities via the EGX we interface Part numers ION6200 PM800 Micrologic Sepam Powerlogic EGX300 Schneider Electric Square D EGX300 EGX300 EGX300SD 4 Version 7.1 432E4020.indd

PowerLogic EGX300 Integrated gateway-server Characteristics Weight EGX300 170g PE86181 Dimensions (HxWxD) Mounting 80.8 x 72 x 65.8 mm Din rail Power-over-Ethernet (PoE) Class 3 Power supply Maximum urden 24 Vdc if not using PoE 4 W Operating temperature -25 to 70ºC Humidity rating 5 to 95% relative humidity (without condensation) at +55ºC Regulatory/standards compliance for electromagenetic interference Emissions (radiated and conducted) EN55022/EN55011/FCC class A Immunity for industrial environments: PowerLogic EGX300 - electrostatic discharge EN 61000-6-2 - radiated RF EN 61000-4-2 - electrical fast transients EN 61000-4-3 - surge EN 61000-4-4 - conducted RF EN 61000-4-5 - power frequency EN 61000-4-6 - magnetic field EN 61000-4-8 Regulatory/standards compliance for safety International (CB scheme) IEC 60950 USA UL508/UL60950 Canada cul (complies with CSA C22.2, no. 60950) Europe EN 60950 Australia/New Zealand AS/NZS 60950 Serial ports Numer of ports 1 Types of ports RS232 or RS485 (2-wire or 4-wire), depending on settings Maximum aud rate Maximum numer of connected devices Modus RTU/ASCII, PowerLogic (SY/MAX), Jus 38400 or 57600 aud depending on settings 32 (directly) 64 (indirectly) Ethernet port Numer of ports 1 Type of port 10/100 Base TX (802.3af) port HTTP, Modus TCP/IP, FTP, SNMP (MIB II), BootP We server Memory for logging, custom we pages and documentation 512 M Installation Din rail mounting 65.8 72 35 57.9 80.8 90.7 45.2 49.5 2.5 68.3 432E4020.indd Version 7.1 5

Schneider Electric 35 Rue Joseph Monier CS 30323 92506 Rueil Malmaison Cedex Tel : +33 (0)1 41 29 70 00 http://www.schneider-electric.com http://www.powerlogic.com PLSED309034EN ART#837617 Dec 2010 2011 - Schneider Electric - All rights reserved As standards, specifications and designs develop from time to time, always ask for confirmation of the information given in this pulication. ION, ION Enterprise, Modus, PowerLogic and PowerView are either trademarks or registered trademarks of Schneider Electric. All other trademarks are property of their respective owners. Printed on recycled paper Pulishing : Schneider Electric Production : Schneider Electric PMC Printing : Made in France