HVAC HANDBOOK HV AC LPH H B001



Similar documents
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX Q [US gpm]

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Horizontal Jet Pumps 1/3-1-1/2 HP

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

The conditions below apply to the curves shown on the following pages.

Series description: Wilo-Star-Z

Multistage high-pressure multistage centrifugal pumps

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

The demand for hot water distribution systems is growing fast and it s a huge opportunity to build your business. When it comes to dependable hot

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Conlift1, Conlift2, Conlift2 ph+

NDP-50 Specifications

Standard offering (pumps)

08.08 Vic-Check Valves

Model 1210C Battery Powered Pump Shown. Description

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Submittal Data Sheet Wilo IPL - Inline Centrifugal Circulators

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

Light Duty Commercial Electric Water Heater

CRN A-F-G-E-HQQE 3x400D 50 HZ

Assisted lift operated 2/2-way solenoid valves Type EV250B

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

V47 Series Temperature Actuated Modulating Water Valves

Laing industrial pumps

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

MAC-120HE-01 Air-Cooled Chiller

Goulds Water Technology

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

SJT / SJM / SJP Large Vertical Pumps

PRESSURE REDUCING CONTROL VALVE

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

4" SUBMERSIBLE PUMPS

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps

Rental Services Temporary Cooling - Flexible Water Hose

POWERS Controls No. 4 Pneumatic Damper Actuator

Series description: Wilo-Yonos MAXO

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

Copper Meter Resetters

In-Line Air Separators

REGULATORS 175/153 Series

HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

MODEL INSTALLATION INSTRUCTIONS

Wilo Building Services - Price Book

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

FLASH TANK ECONOMIZER PRODUCT GUIDE

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

INSTALLATION & OPERATING INSTRUCTIONS

MUELLER FALLING FILM CHILLERS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Select Radiators Installation Guide

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Series description: Wilo-Yonos MAXO-D

BOWIE PUMPS OPERATION - MAINTENANCE

Many Products...One Source

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Automatic Self-Cleaning Strainers

Thermostatic valve Type AVTA

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features

Heating, air-conditioning, cooling

! WARNING. Before using product, read and understand instructions.

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

45 URAI DSL Roots. Quick Specs. Also Available in: Part Number T

FAIRBANKS NIJHUIS FIRE PUMPS.

MEMBRANE VACUUM MINI PUMPS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Welcome to Grindex Pump handbook! With this handbook we want to share some of our wide experience in pumping with submersible pumps.

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

FI Frame-Mounted End Suction Pumps

Morrison Bros. Co. General Product Specifications

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Standard Bills of Materials Commonly Ordered Models Only

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

300 Series PA Pump and Cooler Assemblies

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Transcription:

HVAC HANDBOOK

We endeavour to become the most responsible, the most future-oriented and first of all the most innovative manufacturer in the world Being responsible is our foundation Thinking ahead makes it possible

With an annual production of 10 million pump units, Grundfos is one of the world's leading manufacturers of pumps. Currently, it is the world's largest manufacturer of circulators, with more than 50% of the world market. The product line includes pumps and accessories for Water Supply, Plumbing/HVAC, Industrial, Environmental, and Wastewater products. Grundfos was established in 1945 by the late Poul Due Jensen. Initially, it was named Bjerringbro Die-Casting and Machine Factory, and in 1968 the name was changed to Grundfos. The word Grundfos means "ground spring" in Danish. The Poul Due Jensen Foundation was established as a self-governing institution in 1975, shortly before Due Jensen's death in 1977. Today, the foundation owns 85% of the shares and the founder's family owns the remaining 15% in Grundfos Holding AG. The aim of the foundation is to expand the economic base of the company and develop the Grundfos Group. The capital and profits of the foundation are re-invested into Grundfos companies worldwide. The Grundfos Group is represented in over 40 countries through more then 60 companies. Each company is locally managed and operated, and the products are sold through distributors and wholesalers worldwide. The Group Management is headquartered in Bjerringbro, Denmark with Niels Due Jensen as the Group President. Grundfos Pumps Corporation (USA), established in 1973, is a member of the Grundfos Group and is headquartered in Olathe, Kansas. The North American Regional Headquarters is located in Olathe, KS with distribution centers in Allentown, PA and Fresno, CA. Outside of the USA, Grundfos Canada Inc. is situated in Toronto, Canada, and Grundfos Mexico is situated in Monterrey, Mexico. Innovation is the essance of all we do

TAB ABLE OF CON ONTEN ENTS Table of Contents... i2 Applications / Specifications... i3 Performance at a Glance... i4 SECTION I Small Circulating Pump Quick Fact Sheet... 1-1 UP Terminal Box and Nameplate Convention... 1-3 Submittal Data Sheets Series UP - Open System... 1-5 Series UP - Closed Systems... 1-7 Series UP / 26-116 Sub Data... 1-9 Series UP / 50-75F Sub Data... 1-11 Series UP / BUC5 & BUC7... 1-13 Series UP - Comfort... 1-15 Series UP - MixiMizer... 1-17 Series UP - TLC... 1-19 Series UP - Variable Speed... 1-21 Flanges... 1-23 Timer Control... 1-25 AquaStat (Thermostatic Control)... 1-26 Series UP - Low Voltage Control... 1-27 Product & Flange Part Numbers... 1-28 SECTION II Large Circulating Pump Quick Fact Sheet... 2-1 Submittal Data Sheets VersaFlo / UPS32... 2-3 VersaFlo / UPS40... 2-5 VersaFlo / UPS50... 2-7 VersaFlo / UPS80&100... 2-9 VersaFlo / TP32... 2-11 VersaFlo / TP40... 2-13 VersaFlo / TP50... 2-15 VersaFlo / TP80... 2-17 VersaFlo / TP100... 2-19 Product & Flange Part Numbers... 2-21 SECTION III Submittal Data Sheets Series L / 2.5LM5... 3-1 Series L / 2.5LM6... 3-3 Series L / 2.5LM8... 3-5 Series L / 3.0LM5... 3-7 Series L / 3.0LM6... 3-9 Series L / 3.0LM8... 3-11 Series L / 2.5LP5... 3-13 Series L / 3.0LP5... 3-15 Series L / 3.0LP6... 3-17 Series L / 4.0LP5... 3-19 Product & Flange Part Numbers... 3-21 SECTION IV Technical Data Plumbing & Heating Formulas Pump Formulas & Affinity Laws... 4-1 Conversions... 4-2 NPSH (Net Positive Suction Head)... 4-3 Barometric Readings & Atmospheric Pressures Corresponding to Different Altitudes... 4-3 NSPHA / Vapor Pressure... 4-4 Properties of Water at Various Temperatures... 4-5 Freezing & Boiling Points of Aqueus Solutions of Ethylene Glycol... 4-6 Density of Aqueus Solutions of Ethylene Glycol Viscosity of Aqueus Solutions of Ethylene Glycol... 4-7 Maximum Shock Pressure Caused by Water Hammer... 4-9 Properties of Water at Various Temperatures... 4-10 Formulas... 4-11 Pipe Information Sheets (Steel & Copper)... 4-14 Pressure Loss... 4-16 Friction of Water - Smooth Wall Copper Tubing, Brass, and Plastic Pipe (3/8 to 4 )... 4-20 Friction of Water - New Steel Pipe (1/2 to 4 )... 4-28 Friction Losses Through Pipe Fittings and Valves... 4-36 Hydronic Water Flow Calculator... 4-37 Heat Loss From Bare Steel Pipe & Covered Pipe... 4-38 Typical Symbols... 4-39 Circulator Replacement Guide (UP)... 4-40 VersaFlo UPS/TP Cross Reference Guide... 4-41 Apartment/Condominiums/Office/Hospitals/Schools Capacity Sizing... 4-43 Blank Grids.... 4-48 For the latest information regarding our products, visit our Website at www.grundfos.com i-2

BOILER/HYDRONIC HEATING CHILLED WATER CIRCULATION COOLING TOWERS DEAERATORS DOMESTIC HOT WATER DRAINAGE EFFLUENT FLUID TRANSFER FOUNTAINS GLYCOL SOLUTIONS GROUND SOURCE HEAT PUMPS HEAT PUMPS HOT WATER RECIRCULATION HOT WATER AIR HANDLING HVAC INDUSTRIAL MARINE SERVICE PAINT BOOTH PROCESS WATER QUENCH WATER RADIANT FLOOR HEAT SEWAGE SOLAR SUMP SWIMMING POOLS SNOW MELT SYSTEMS APPLICATIONS IONS 1 2 3 SERIES SERIES SERIES UP VersaFlo L CIRCULATORS PUMPS PUMPS Section In This Handbook Capacity in U.S. gpm SPECIFIC FICATIONS IONS 1 2 2 3 SERIES SERIES SERIES SERIES UP VersaFlo VersaFlo L UPS TP CIRCULATORS PUMPS PUMPS PUMPS 0-46 gpm 9-270 gpm 8 to 300 gpm 30-600 gpm Single: Single: Total Head in feet feet feet feet feet 0-37.5 1-62 3.5-67.5 8-180 HP 1/25 to 1/6 1/3 to 3 1/3 to 3 3/4 to 20 Temp. Range 32 F - 230 F 14 F - 230 F 5 F - 288 F 5 F - 250 F Max. Working Pressure 145 PSI 145 PSI 145 PSI 175 PSI i-3

PERFORMANC ORMANCE AT A GLANC ANCE CIRCULATOR CURVES FLOW IN U.S. GALLONS PER MINUTE i-4 NOTE: Performance curves shown above are approximations only. For more detailed performance information, refer to the Submittal Data pages later in this book.

GRUNDFOS SERIES UP SECTION 1

QUICK FACT SHEET Small Circulating Pumps Series UP15 s Open & Closed Systems AVAILABLE MODELS (Closed Systems): UPS15-42F & FR (3 Speed) UP15-42F & FR BRUTE II UP15-10F & FR UP15-42FC & FRC CONNECTIONS: Flange, cast iron, (2) 1/2 diameter bolt holes AVAILABLE MODELS (Open Systems): UP15-10B5 UP15-18B5 UP15-18SU & SF UP15-42B5 UP15-10B7 UP15-18B7 UP15-42SU & SF UP15-42B7 UPS15-42SU & SF CONNECTIONS: B5 - Sweat fittings, Bronze, 1/2 SU - Union, stainless steel, 1-1/4 NPSM B7 - Sweat fittings, Bronze, 3/4 SF - Flange, stainless steel, (2) 1/2 diam. bolt holes FLOW RANGE: 0 to 20 gpm MAXIMUM FLUID TEMPERATURE MINIMUM FLUID HEAD RANGE: 0 to 16.5 feet (Open Systems): 220 F* (104 C) TEMPERATURE: (Closed Systems): 230 F (110 C) 36 F (2 C) MOTOR: 2 pole, single phase PRESSURE: 145 psi maximum (working) Series UP26 s Open & Closed Systems AVAILABLE MODELS (Closed Systems): UP26-64F UP26-96F UP26-99F UP43-75F UP26-116F CONNECTIONS: Flange, cast iron, (2) 1/2 diameter bolt holes AVAILABLE MODELS (Open Systems): UP25-64SU & SF UP26-96BF UP26-99BF UP43-75BF UP26-116BF CONNECTIONS: SU - Union, stainless steel, 1-1/4 NPSM BF - Flange, bronze, (2) 1/2 diam. bolt holes SF - Flange, stainless steel, (2) 1/2 diam. bolt holes FLOW RANGE: 0 to 46 gpm HEAD RANGE: 0 to 37.5 feet MOTOR: 2 pole, single phase Series UP BUC5 & BUC7 MAXIMUM FLUID TEMPERATURE (Open Systems): 220 F* (104 C) (Closed Systems): 230 F (110 C) MINIMUM FLUID TEMPERATURE: 32 F (0 C) PRESSURE: 145 psi maximum (working) AVAILABLE MODELS: UP15-18BUC5 UP15-42BUC5 UP15-18BUC7 UP15-42BUC7 CONNECTIONS: BUC5 = 1/2 copper pipe, female sweat fittings BUC7 = 3/4 copper pipe, female sweat fittings FLOW RANGE: 0 to 16 gpm HEAD RANGE: 0 to 15 feet MOTOR: 2 pole, single phase MAXIMUM FLUID TEMPERATURE: 200 F* (93 C) MINIMUM FLUID TEMPERATURE: 36 F (2 C) PRESSURE: 145 psi max. (working) *NOTE: It is recommended to keep the operating temperature as low as possible (ie., below 140 F, 60 C to avoid precipitation of calcium). 1-1

Grundfos Circulators Series UP 50-75F Closed System FLANGE: 2 slotted, 4-bolt FLOW RANGE: 0 to 45 gpm HEAD RANGE: 0 to 26 feet MODEL: UP50-75F, 60 Hz MOTOR: 2 pole, single phase MAXIMUM FLUID TEMPERATURE: 230 F (110 C) MINIMUM FLUID TEMPERATURE: 32 F (0 C) PRESSURE: 145 psi maximum (working) MATERIALS OF CONSTRUCTION: Closed Systems & Open Systems DESCRIPTION (Closed) MATERIAL DESCRIPTION (Open) MATERIAL Shaft, Upper & Lower Radial Aluminum Oxide Inlet Cone, Bearing Plate, Stainless Steel Bearings Ceramic Bearing Retainers, Rotor Can, 304 Thrust Bearing Metal Rotor Cladding, Shaft Retainer, Impregnated Check Valve Spring on Carbon (UP BUC5 & BUC7) O-ring & Gaskets Impeller EP (Ethylene Propylene Rubber) PES Composite (30% Glass Filled) Volute Retainer (SU & SF Models) & Stator Housing Pump Housing (Volute ) Aluminum Silicon Bronze (c875) or 304SS or Cast Iron Non Asbestos Fiber Union Gasket on BUC5 & BUC7 Tail Piece & Union Nut on Brass BUC5 & BUC7 (UNS C36000) Teminal Box Noryl Check Valve Housing, Valve POM and Torpedo (Polyoxymehtylene) Noryl is a registered trademark of General Electric Company. BRUTE II is a registered trademark of Grundfos Pumps Corporation. 1-2 L-PH-QF-002 Rev. 01/01 PRINTED IN USA

UP Terminal Box and Nameplate Convention Prior Convention Orientation: Pumping Down Terminal Box: TB2 Nameplate: 270 Clockwise from TB Current Convention Orientation: Pumping Up Terminal Box: 9H Nameplate: 12H 1-3

1-4

Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps Submittal Data JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: APPROVED BY: ORDER NO: SPECIFICATION REF: Series UP OPEN SYSTEMS 60 Cycle QUANTITY TAG NO. MODEL NO. GPM FEET VOLT PHASE COMMENTS Technical Data FLOW RANGE: 0 to 46 U.S. GPM MIN. FLUID TEMPERATURE for UP15: 36 F (2 C) HEAD RANGE: 0 to 32 Feet MIN. FLUID TEMPERATURE for ALL OTHERS: 32 F (0 C) MOTORS: 2 Pole, Single Phase MAXIMUM FLUID TEMPERATURE: 220 F (104 C), Maximum design temperature. FOR OPEN SYSTEMS - 140 F (60 C) Is the maximum recommended fluid temperature to avoid precipitation of calcium in water. FOR CLOSED SYSTEMS - 230 F (110 C) Ambient Air Temp. 130 F (55 C) 140 F (60 C) 160 F (71 C) 175 F (79 C) Maximum Water Temp. 220 F (104 C) 210 F (99 C) 190 F (88 C) 175 F (79 C) MAXIMUM WORKING PRESSURE: 145 PSI MINIMUM REQUIRED INLET PRESSURE: Temperature 220 F (104 C) 190 F (88 C) 140 F (60 C) Pressure 36 Ft. (11m) 9.0 Ft. (2.8m) 3.0 Ft. (0.9m) 15.6 psi 4.0 psi 1.3 psi Mounting Positions Recommended Optional DO NOT Mount Motor Shaft in Vertical Position FOR INDOOR USE ONLY Dimensions, and Weights UP26-96BF, UP26-99BF, & UP43-75BF UP15-18SF, UP15-42SF, UPS15-42SF & UP25-64SF UP15-18SU, UP15-42SU, UPS15-42SU & UP25-64SU UP15-10B5 & B7, UP15-18B5 & B7, UP15-42B5 & B7 Shipping OPEN SYSTEM MODELS A B C D E F Connection Type and Size Wt. (Lbs.) UP15-10B5 5 4 11 /16 4 4 3 1 /2 Sweat 1 /2" 6 UP15-10B7 6 3 /8 5 1 /8 4 3 13 /16 3 1 /4 Sweat 3 /4" 6.7 UP15-18SU & UP/UPS15-42SU 5 7 /8 5 1 /16 4 3 7 /16 3 1 /4 Union 1 1 /4" NPSM 5 UP15-18SF & UP/UPS15-42SF 6 1 /2 5 1 /4 4 4 3 /16 3 1 /4 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 6 UP15-18B5 & UP15-42B5 5 4 11 /16 4 3 1 /2 3 1 /4 Sweat 1 /2" 6 UP15-18B7 & UP15-42B7 6 3 /8 5 1 /8 4 3 13 /16 3 1 /4 Sweat 3 /4" 6.7 UP25-64SU 5 7 /8 5 13 /16 4 13 /16 4 3 1 /2 Union 1 1 /4" NPSM 9 UP25-64SF 6 1 /2 6 1 /16 4 13 /16 4 3 /16 3 1 /2 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 10 UP26-96BF 6 1 /2 6 3 /8 5 1 /16 4 1 /8 3 1 /2 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 12.5 UP26-99BF 6 1 /2 6 3 /8 5 1 /16 4 1 /8 3 1 /2 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 12.5 UP43-75BF 8 1 /2 6 11 /16 5 3 /16 4 3 /4 3 1 /2 3 7 /16 Flange (2) 1 /2" Dia. Bolt Holes 15 NOTES: All dimensions are in inches. "F" dimension is the flange bolt centerline to centerline. 1-5

Performance Stainless Steel or Bronze Construction - Flange, Union, or Sweat Mount UP 1 15-42 B5 UP 2 15-18 B5 UP 3 15-10 B5 4 UP 4 15-42 B7 UP 5 15-18 B7 UP 6 15-10 B7 HEAD (FT.) 2 1 HEAD (FT.) 5 3 6 CAPACITY (U.S. GPM) CAPACITY (U.S. GPM) 7 UP 7 26-99 BF 11 UP 8 43-75 BF UP 9 26-96 BF 12 UP 10 25-64 SU & SF UP 11 15-42 SU & SF 13 UPS 12 15-42 SU & SF Spd. 3 HEAD (FT.) 10 8 9 UPS 13 15-42 SU & SF Spd. 2 112 UP 14 15-18 SU & SF UPS 15-42 SU & SF Spd. 1 15 15 Note: Performance shown is for 115V models. 230V models will 16 vary slightly. 12 12 13 14 15 11 12 Electrical Data MODEL VOLTS AMPS WATTS HP CAPACITOR UP15-10B5 & B7 115.55 58 1 /25 8µF/180V UP15-18SU, SF, & B5 115.74 85 1 /25 10µF/180V 230.40 90 1 /25 2µF/400V UP15-18B7 115.74 85 1 /25 10µF/180V 230.40 96 1 /25 2µF/400V UP15-42SU, SF, & B5 115.74 85 1 /25 10µF/180V 230.41 95 1 /25 2µF/400V UP15-42B7 115.74 85 1 /25 10µF/180V 230.41 95 1 /25 2µF/400V Materials of Construction DESCRIPTION Inlet Cone, Bearing Plate, Bearing Retainers, Rotor Can, Rotor Cladding, Shaft Retainer. Volute Retainer (SU & SF Models) & Stator Housing Shaft, Upper & Lower Radial Bearings Thrust Bearing CAPACITY (U.S. GPM) MATERIAL 304 Stainless Steel Aluminum Aluminum Oxide Ceramic Metal Impregnated Carbon MODEL VOLTS AMPS WATTS HP CAPACITOR UP25-64SU & SF 115 1.70 180 1 /12 8µF/180V 230.80 175 1 /12 2.5µF/380V UP26-96BF 115 1.70 205 1 /12 10µF/180V 230.80 205 1 /12 2.5µF/380V UP26-99BF 115 2.15 245 1 /6 10µF/180V 230 1.07 245 1 /6 2.5µF/380V UP43-75BF 115 2.15 215 1 /6 10µF/180V 230 1.07 220 1 /6 2.5µF/380V DESCRIPTION O'Ring & Gaskets Pump Housing (Volute) MATERIAL EP (Ethylene Propylene Rubber) Silicone Bronze C875 or Stainless Steel Impeller PES Composite (30% Glass Filled) Terminal Box Noryl 1-6 L-UP-TL-007 Rev. 01/01 PRINTED IN USA

Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps Submittal Data JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: APPROVED BY: ORDER NO: SPECIFICATION REF: Series UP CLOSED SYSTEMS 60 Cycle QUANTITY TAG NO. MODEL NO. GPM FEET VOLT PHASE COMMENTS Technical Data FLOW RANGE: 0 to 46 U.S. GPM MIN. FLUID TEMPERATURE for UP15: 36 F (2 C) HEAD RANGE: 0 to 32 Feet MIN. FLUID TEMPERATURE for ALL OTHERS: 32 F (0 C) MOTOR: 2Pole, Single Phase MAXIMUM FLUID TEMPERATURE CLOSED SYSTEMS: 230 F (110 C) Ambient Air Temp. 95 F (35 C) 130 F (55 C) 140 F (60 C) 160 F (71 C) 175 F (79 C) Maximum Water Temp. 230 F (110 C) 220 F (104 C) 210 F (99 C) 190 F (88 C) 175 F (79 C) Mounting Positions Recommended MAXIMUM WORKING PRESSURE: 145 PSI Dimensions, and Weights B C Fluid Temp Feet of Water Inlet Pressure MINIMUM REQUIRED INLET PRESSURE 230 F (110 C) 190 F (88 C) 140 F (60 C) Optional 36 Ft. (1.10m) 9.0 Ft. (2.8m) 3.0 Ft. (0.9m) 15.6 psi 4.0 psi 1.3 psi FOR INDOOR USE ONLY B C B C DO NOT Mount Motor Shaft in Vertical Position E E E A D A D F A D F F UP15-42FR UPS15-42FR UP15-42F/FC UPS15-42F UP26/43 Shipping À CLOSED SYSTEM MODELS A B C D E F Connection Type and Size Wt. (Lbs.) UP15-42F (BRUTE II ) & UPS15-42F 6 1 /2 5 1 /4 4 4 3 /16 3 1 /4 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 7 1 /4 UP15-FR (BRUTE II ) & UPS15-42FR 6 1 /2 5 15 /16 4 3 3 /4 3 1 /4 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 7 1 /4 UP15-42FC (*Brute II w/ check valve) 6 1 /2 5 1 /4 4 4 3 /16 3 1 /4 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 7 1 /4 UP26-64F & UP26-96F 6 1 /2 6 3 /8 5 1 /16 4 1 /8 3 1 /2 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 11 1 /4 UP26-99F 6 1 /2 6 3 /8 5 1 /16 4 1 /8 3 1 /2 3 5 /32 Flange (2) 1 /2" Dia. Bolt Holes 12 1 /2 UP43-75F 8 1 /2 6 11 /16 5 3 /16 4 3 /4 3 1 /2 3 7 /16 Flange (2) 1 /2" Dia. Bolt Holes 13 1 /2 NOTES: All dimensions are in inches. "F" dimension is the flange bolt centerline to centerline. *Criculators w/ check valve have a maximum water temperature of 200 F. 1-7

Performance Curves Cast Iron Construction Flange Mount Note: Performance shown is for 115V Models. 230V models will vary slightly. Electrical Data MODEL VOLTS AMPS WATTS HP CAPACITOR UP15-42F/FR/FC 115.74 85 1 /25 10µF/180V (BRUTE II ) 230.43 95 1 /25 2µF/400V UPS15-42F Spd. 3 115.74 85 1 /25 10µF/180V (115V) Spd. 2 ---.57 65 --- --- Spd. 1 ---.40 45 --- --- UPS15-42F Spd. 3 230.43 95 1 /25 2µF/400V (230V) Spd. 2 ---.19 40 --- --- Spd. 1 ---.14 30 --- --- NOTE: All UP models are single speed except for the 3-speed UPS15-42F, 115 and 230 volt. MODEL VOLTS AMPS WATTS HP CAPACITOR UP26-64F 115 1.70 185 1 /12 8µF/180V 230.80 175 1 /12 2.5µF/380V UP26-96F 115 1.70 205 1 /12 10µF/180V 230.80 205 1 /12 2.5µF/380V UP26-99F 115 2.15 245 1 /6 10µF/180V 230 1.07 245 1 /6 2.5µF/380V UP43-75F 115 2.15 215 1 /6 10µF/180V 230 1.07 220 1 /6 2.5µF/380V Materials of Construction DESCRIPTION MATERIAL DESCRIPTION MATERIAL Inlet Cone, Bearing Plate, Bearing Retainers, 304 Stainless Steel Pump Housing (Volute) Cast Iron Rotor Can, Rotor Cladding, Shaft Retainer O'Ring & Gaskets EP (Ethylene Propylene Rubber) Stator Housing Aluminum Impeller PES Composite (30% Shaft, Upper & Lower Radial Bearings Aluminum Oxide Ceramic Glass Filled) Thrust Bearing Metal Impregnated Carbon Terminal Box Noryl Check Valve ACETAL With 302 Stainless Steel Spring & Nitrile Rubber Seats NOTE: Noryl is a registered trademark of General Electric Company. BRUTE II is a registered trademark of Grundfos Pumps Corporation. 1-8 L-UP-TL-107 Rev. 12/00 PRINTED IN USA

Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps Submittal Data JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: APPROVED BY: ORDER NO: SPECIFICATION REF: UP 26-116 60 Cycle QUANTITY TAG NO. MODEL NO. GPM FEET VOLT PHASE COMMENTS Technical Data FLOW RANGE: 0 38.5 U.S. GPM HEAD RANGE: 0 37.5 Feet MOTOR: 2 Pole, Single Phase, PSC MINIMUM FLUID TEMPERATURE: 32 F (0 C) MAXIMUM FLUID TEMPERATURE: 150 F (65 C) MAXIMUM WORKING PRESSURE: 145 PSI (10 Bars) Performance Curves HEAD (FT.) CONNECTION TYPE & SIZE: Flange - (2)-1/2 Dia. Bolt Holes MINIMUM REQUIRED INLET PRESSURE: Fluid Temp. 150 F (65.5 C) 140 F (60 C) Feet of Water 4 Ft. 3 Ft. Inlet Pressure 1.7 psi 1.3 psi Materials of Construction Inlet Cone, Bearing Plate, Bearing Retainers, Rotor Can, Rotor Cladding, Shaft Retainer Impeller Stator Housing Shaft, Upper and Lower Radial Bearings Thrust Bearing Pump Housing (volute) O-Ring and Gaskets Terminal Box Mounting Positions Recommended FOR INDOOR USE ONLY 304 Stainless Steel Note: Noryl is a registered trademark of General Electric Company Optional DO NOT Mount Motor Shaft in Vertical Position PES Composite (30% Glass Filled) Aluminum Aluminum Oxide Ceramic Metal Impregnated Carbon Cast Iron or Silicon Bronze C875 EP (Ethylene Propylene Rubber) Noryl CAPACITY (U.S. GPM) Nomenclature UP 26-116 B F Circulator Pump Nominal diameter of ports in mm Flange Bronze Maximum head in meters x 10 Dimensions and Weight MODEL A B C D E F1 SHIP. WT. UP26-116F & BF 6-1/2 6-3/8 5-1/16 4-1/8 3-1/2 3-5/32 12-1/2 lbs. Electrical Data MODEL VOLTS AMPS WATTS HP CAPACITOR UP26-116F & BF 230 1.75 385 1/6 2.5µF/380V NOTES: All dimensions are in inches. 1 F dimension is the flange bolt centerline to centerline. Subject to change without notice. L-UP-TL-017 01/01 PRINTED IN USA 1-9

1-10

Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps Submittal Data JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: APPROVED BY: ORDER NO: SPECIFICATION REF: Series UP 50-75F 60 Cycle QUANTITY TAG NO. MODEL NO. GPM FEET VOLT PHASE COMMENTS Technical Data FLOW RANGE: 0 to 45 U.S. GPM HEAD RANGE: 0 to 27 Feet MOTOR: 2 Pole, Single Phase MINIMUM FLUID TEMPERATURE: 32 F (0 C) MAXIMUM FLUID TEMPERATURE: 230 F (110 C) Ambient Air Temp. 95 F (35 C) 130 F (55 C) 140 F* (60 C) 160 F (71 C) 175 F (79 C) Maximum Water Temp. 230 F (110 C) 220 F (104 C) 210 F (99 C) 190 F (88 C) 175 F (79 C) MAXIMUM WORKING PRESSURE: 145 PSI 230 F (110 C) 190 F (88 C) 140 F* (60 C) MINIMUM REQUIRED INLET PRESSURE : 36 Ft. (1.10m) 9.0 Ft. (2.8m) 3.0 Ft. (0.9m) 15.6 psi 4.0 psi 1.3 psi Performance Curves Dimensions and Weight UP50-75F 60Hz MODEL A B C D E F Shipping Wt. UP50-75F 8 1 /2 7 1 /2 5 1 /16 4 7 /8 3 1 /2 4 1 /16 15 1 /2 lbs. NOTES: All dimensions are in inches. "F" dimension is the flange bolt centerline to centerline. Mounting Positions Recommended Optional DO NOT Mount Motor Shaft in Vertical Position FOR INDOOR USE ONLY Materials of Construction Inlet Cone, Bearing Plate, Bearing Retainers Stainless Steel Rotor Can, Rotor Cladding, Shaft Retainer, Impeller PES Composite (30% Glass Filled) Stator Housing Aluminum Shaft, Upper and Lower Radial Bearings Aluminum Oxide Ceramic Thrust Bearing Metal Impregnated Carbon Pump Housing (volute) Cast Iron O-Ring and Gaskets EP (Ethylene Propylene Rubber) Terminal Box Noryl Note: Noryl is a registered trademark of General Electric Company Electrical Data Model Volts Amps Watts HP Capacitor UP50-75F 115 2.15 215 1 / 6 10µF/180V UP50-75F 230 1.07 220 1 / 6 2.5µF/380V L-UP-TL-015 12/00 PRINTED IN USA 1-11

1-12

Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps with Integral Check Valve and Bronze Union Sweat Fittings Submittal Data JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: APPROVED BY: ORDER NO: SPECIFICATION REF: Series UP BUC5 & BUC7 60 Cycle QUANTITY TAG NO. MODEL NO. GPM FEET VOLT PHASE COMMENTS Technical Data FLOW RANGE: 0 16 U.S. GPM HEAD RANGE: 0 15 Feet MOTORS: 2 Pole, Single Phase MINIMUM FLUID TEMPERATURE: 36 F (2 C) MAXIMUM FLUID TEMPERATURE: 200 F (93 C) MAXIMUM WORKING PRESSURE: 145 PSI Mounting Positions FOR OPEN SYSTEMS - 140 F (60 C) Is the maximum recommended fluid temperature to avoid precipitation of calcium in water. Recommended Ambient Air Temp. 95 F (35 C) 130 F (55 C) 140 F (60 C) 160 F (71 C) 175 F (79 C) Maximum Water Temp. 230 F (110 C) 220 F (104 C) 210 F (99 C) 190 F (88 C) 175 F (79 C) MINIMUM REQUIRED INLET PRESSURE: Temperature 200 F (93 C) 140 F (60 C) Pressure 9.0 Ft. (2.8m) 3.0 Ft. (0.9m) 4.0 psi 1.3 psi Performance Curves HEAD (FT.) 1 3 2 5 1. UP15-10BUC5 2. UP15-10BUC7 3. UP15-18BUC5 4. UP15-18BUC7 5. UP15-42BUC5 6. UP15-42BUC7 60 Hz CAPACITY (U.S. GPM) Dimensions and Weight Model A B C D E Connection Ship Wt. UP15BUC5 6 1 /2 5 1 /4 4 3 3 /16 3 1 /4 Sweat 1 /2 7 1 /4 lbs. UP15BUC7 7 3 /4 5 1 /4 4 3 3 /4 3 1 /4 Sweat 3 /4 8 lbs. 4 6 *NOTES: All dimensions are in inches. Optional Materials of Construction DO NOT Mount Motor Shaft in Vertical Position FOR INDOOR USE ONLY Nomenclature: B-Bronze, lead free pump housing U - Union connection for check valve C-Integral check valve 5-1/2 copper pipe, female sweat fittings 7-3/4 copper pipe, female sweat fittings Inlet Cone, Bearing Plate, Bearing Retainers Stainless Steel Rotor Can, Rotor Cladding, Shaft Retainer, Check Valve Spring Stator Housing Aluminum Shaft, Upper and Lower Radial Bearings Aluminum Oxide Ceramic Thrust Bearing Metal Impregnated Carbon Pump Housing (volute) Lead Free Bronze (Alloy C875) Tail Piece and Union Nut Brass (UNS C36000) O-Ring and Gaskets EP (Ethylene Propylene Rubber) Impeller PES Composite (30% Glass Filled) Terminal Box Noryl Check Valve Housing, Valve and Torpedo POM (polyoxymethylene) Union Gasket Non Asbestos Fiber Note: Noryl is a registered trademark of General Electric Company Electrical Data Model Volts Amps Watts HP Capacitor UP15-10BUC5 115 0.55 60 1/25 8µF/180V UP15-10BUC7 115 0.55 60 1/25 8µF/180V UP15-18BUC5 115 0.74 85 1/25 10µF/180V UP15-18BUC7 115 0.74 85 1/25 10µF/180V UP15-42BUC5 115 0.74 85 1/25 10µF/180V UP15-42BUC7 115 0.74 85 1/25 10µF/180V L-UP-TL-013 Rev. 01/01 PRINTED IN USA Grundfos Pumps Corporation 3131 N. Business Park Avenue Fresno, CA 93727 Customer Service Centers: Allentown, PA Fresno, CA Phone: (559) 292-8000 Fax: (559) 291-1357 ISO 9001 REGISTERED Canada: Oakville, Ontario Mexico: Apodaca, N.L. Visit our website at www.us.grundfos.com 1-13

1-14

Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps Submittal Data JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: APPROVED BY: ORDER NO: SPECIFICATION REF: Series UP Timer & Line Cord Models 60 Cycle QUANTITY TAG NO. MODEL NO. GPM FEET VOLT PHASE COMMENTS Technical Data FLOW RANGE: 0 to 17 U.S. GPM HEAD RANGE: 0 to 16 Feet MOTORS: 2 Pole, Single Phase MAXIMUM FLUID TEMPERATURE: 150 F (66 C), Maximum design temperature. MIN. FLUID TEMPERATURE for UP15: 36 F (2 C) TIMER: 24 hours 3 positions (ON/TIMER/OFF) 15 minute interval. LINE CORD: Six-Foot 18-3 with 5-15P grounded plug. MAXIMUM WORKING PRESSURE: 145 PSI MINIMUM REQUIRED INLET PRESSURE: At 150 F (66 C), 3.0 Ft. (0.9m) 1.3 PSI. Dimensions, and Weights Mounting Positions Recommended Optional DO NOT Mount Motor Shaft in Vertical Position FOR INDOOR USE ONLY UP15-10B5 & B7, UP15-18B5 & B7, UP15-42B5 & B7 UP15-18SU UP15-10BUC5 UP15-10BUC7 Timer & Line Cord 1.6 C 2.85.425 2.95 1.25 4.25 3.77 6 F F F Shipping TIMER & LINE CORD MODELS A B C D E F Connection Type and Size Wt. (Lbs.) UP15-10B5/LC & TLC 5 6 3 /16 5 1 /2 4 3 1 /2 4 Sweat 1 /2" 6.5 UP15-10B7/ LC & TLC 6 3 /8 6 5 /8 5 1 /2 3 13 /16 3 1 /4 4 Sweat 3 /4" 7.2 UP15-18B5/LC & TLC 5 6 3 /16 5 1 /2 3 1 /2 3 1 /4 4 Sweat 1 /2" 6.5 UP15-18B7/LC & TLC 6 3 /8 6 5 /8 5 1 /2 3 13 /16 3 1 /4 4 Sweat 3 /4" 7.2 UP15-42B5/LC & TLC 5 6 3 /16 5 1 /2 3 1 /2 3 1 /4 4 Sweat 1 /2" 6.5 UP15-42B7/LC & TLC 6 3 /8 6 5 /8 5 1 /2 3 13 /16 3 1 /4 4 Sweat 3 /4" 7.2 UP15-10BUC5/LC & TLC 6 1 /2 6 3 /4 5 1 /2 3 3 /16 3 1 /4 4 Sweat 1 /2 7.7 UP15-10BUC7/LC & TLC 7 3 /4 6 3 /4 5 1 /2 3 3 /4 3 1 /4 4 Sweat 3 /4 8.5 UP15-18SU/LC & TLC 5 7 /8 6 4 /16 5 1 /2 3 7 /16 3 1 /4 4 Union 1 1 /4" NPSM 5.5 NOTES: All dimensions are in inches. 1-15

Performance Stainless Steel or Bronze Construction - Flange, Union, or Sweat Mount HEAD (FT.) 20 15 10 1. UP15-10B5 2. UP15-10B7 3. UP15-10BUC5 4. UP15-10BUC7 5. UP15-18SU 6. UP15-18B7 7. UP15-18B5 8. UP15-42B5 9. UP15-42B7 Note: Performance shown is for 115V models. 230V models will vary slightly. 5 5 7 8 6 9 3 1 4 2 0 0 5 10 15 20 CAPACITY (U.S. GPM) Electrical Data MODEL VOLTS AMPS WATTS HP CAPACITOR UP15-10B5 & B7 115.55 60 1 /25 8µF/180V UP15-18SU & B5 115.74 85 1 /25 10µF/180V UP15-18B7 115.74 85 1 /25 10µF/180V MODEL VOLTS AMPS WATTS HP CAPACITOR UP15-42B5 115.74 85 1 /25 10µF/180V UP15-42B7 115.74 85 1 /25 10µF/180V UP15-10BUC5/7 115 0.55 60 1/25 8µF/180V Materials of Construction DESCRIPTION Inlet Cone, Bearing Plate, Bearing Retainers, Rotor Can, Rotor Cladding, Shaft Retainer. Pump Housing (Volute) on UP15-18SU/SF Volute Retainer (SU Model) & Stator Housing Shaft, Upper & Lower Radial Bearings Thrust Bearing MATERIAL 304 Stainless Steel Aluminum Aluminum Oxide Ceramic Metal Impregnated Carbon DESCRIPTION O'Ring & Gaskets Pump Housing (Volute) for UP15-10B5 & B7, UP15-18B5 & B7, UP15-42B5 & B7, UP15-10BUC5 & B7 MATERIAL EP (Ethylene Propylene Rubber) Silicone Bronze C875 Impeller PES Composite (30% Glass Filled) Terminal Box Noryl 1-16 L-UP-TL-034 Rev. 8/00 PRINTED IN USA

Wet-Rotor, In-Line, Single Stage, Maintenance Free, Circulator Pumps Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET VOLT PHASE COMMENTS Technical Data FLOW RANGE: 0 3 U.S. GPM HEAD RANGE: 0 5.4 Feet MOTORS: Single Phase, 115V FOR OPEN SYSTEMS - 140 F (60 C) Is the maximum recommended fluid temperature to avoid precipitation of calcium in water. Ambient Air Temp. 149 F (65 C) 169 F (75 C) Maximum Water Temp. 203 F (95 C) 176 F (80 C) MINIMUM REQUIRED INLET PRESSURE: Temperature 203 F (95 C) 185 F (85 C) Pressure 9 Ft. (2.8m) 1.6 Ft. (0.5m) 4.0 psi 0.7 psi MOTOR: A green light on the motor is on when power is supplied to the pump. TIMER: 24-hour AM/PM, 20 minute interval. JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: APPROVED BY: ORDER NO: SPECIFICATION REF: MINIMUM FLUID TEMPERATURE: 36 F (2 C) MAXIMUM FLUID TEMPERATURE: 203 F (95 C) MAXIMUM WORKING PRESSURE: 145 PSI Mounting Positions FOR INDOOR USE ONLY Dimensions and Weights Nomenclature Series UP Comfort 60 Cycle B - Brass, lead free pump housing 5 - ½" Copper Pipe, Female sweat fittings N5 - ½" NPT - Female thread fitting U - Union connection, 1¼" NPSM with Isolation valve & check valve. A - Thermostat T - 24-hour timer LC - Line cord and plug DO NOT Mount in this Position UP 10-16B5/BN5 UP 10-16BU Model Type L1 L2 H1 H2 H3 H4 B1 B2 Wt. Lbs Connection UP 10-16 B5/LC 3 1/8 1 1/2 5 1/4 3 3 1/3 2.9 Sweat 1/2" UP 10-16 B5/TLC 3 1/8 3 1/2 1 1/2 8 1/16 3 3 1/3 3.4 Sweat 1/2" UP 10-16 B5/ATLC 3 1/8 3 1/2 1 1/2 8 1/16 3 3 1/3 3.4 Sweat 1/2" UP 10-16 BN5/LC 3 1/8 1 1/2 5 1/4 3 3 1/3 2.9 NPT 1/2" UP 10-16 BN5/TLC 3 1/8 3 1/2 1 1/2 8 1/16 3 3 1/3 3.4 NPT 1/2" UP 10-16 BN5/ATLC 3 1/8 3 1/2 1 1/2 8 1/16 3 3 1/3 3.4 NPT 1/2" UP 10-16 BU/LC 4 1/3 1 7/8 5 1/4 3 3 1/3 3.4 Union - 11/4" NPSM UP 10-16 BU/TLC 4 1/3 1 7/8 8 1/16 3 3 1/3 3.8 Union - 11/4" NPSM UP 10-16 BU/ATLC 4 1/3 1 7/8 8 1/16 3 3 1/3 3.8 Union - 11/4" NPSM 1-17 New Item New Item New Item New Item New Item New Item New Item New Item New Item New Item New Item

Performance Comfort UP 10-16B/B5 Comfort UP 10-16BU HEAD (FT.) HEAD (FT.) CAPACITY (US GPM) CAPACITY (US GPM) Electrical Data 1 X 115V P1 [W] 1 1/1 [A] 25 0.23 Product Range Electrical connection The pump is fitted with 5 foot cord & 115V plug. Motor protection Impedance-protected. No external motor protection required. Thermostat: The built-in thermostat can be set to stop the pump at a preset liquid temperature. The setting range is 95-150 F. The thermostat function can be interrupted by turning the thermostat to the position. The factory setting of the thermostat is: 95 F (35 C) UP 10-16 B5/LC UP 10-16 B5/TLC UP 10-16 B5/ATLC UP 10-16 BN5/LC UP 10-16 BN5/TLC UP 10-16 BN5/ATLC UP 10-16 BU/LC UP 10-16 BU/TLC UP 10-16 BU/ATLC Materials of Construction DESCRIPTION Stator housing Spherical separator Rotor can complete Rotor, impeller Pump housing Brass MS 58 Isolation Valve PPO MATERIAL Aluminium Stainless steel Stainless steel/tungsten carbide Stainless steel, EPDM, PPO, PFTE, graphite DESCRIPTION MATERIAL Terminal box cover, Motor Cover PA66/6 Screw Stainless steel Light Lexan Cable, Cable Relief PVC Insulating cover EPP 55 Orings EPDM Check Valve POM L-UP-TL-040 Rev. 03/01 PRINTED IN USA 1-18