Series description: Wilo-Yonos MAXO

Size: px
Start display at page:

Download "Series description: Wilo-Yonos MAXO"

Transcription

1 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/, /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/, Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power adjustment. Application Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems. Type key Example: Wilo-Yonos MAXO 3/.5-1 Yonos MAXO High-efficiency pump (screw-end or flange-end pump), electronically controlled 3/ Nominal connection diameter.5-1 Nominal delivery head range [m] Special features/product advantages Maximum efficiency thanks to ECM technology LED display for showing delivery head setting Quick and convenient electrical connection with Wilo-Connector Collective fault signal on all types for assuring system availability Simple installation due to PN 6/PN 1 combination flanges (with DN to DN 65) Can be used in cooling/air-conditioning systems without ambient temperature limits Pump housing with cataphoretic coating for preventing corrosion due to condensation formation Equipment/function Operating modes Δp-c for constant differential pressure Δp-v for variable differential pressure Manual functions Operating mode setting Setting of pump output (delivery head) Automatic functions Variable power adjustment depending on the operating mode Deblocking function Soft start Integrated full motor protection Signal and display functions Collective fault signal (potential-free NC contact) Fault signal light LED segment display for displaying the delivery head and fault codes Equipment Wrench attachment point on pump body (for threaded pipe union pumps) Quick electrical connection with Wilo-Connector. For the connection of the mains and SSM lines, with integrated strain relief For flange-end pumps: Flange versions Standard version for DN to DN 65 pumps: PN 6/1 combination flange (PN 16 flange according to EN 19-) for PN 6 and PN 16 counter flanges Scope of delivery Pump Including gaskets for threaded connection Incl. washers for flange screws (for nominal connection diameters DN - DN 65) Including installation and operating instructions Accessories Screwed connections for threaded connection Adapter fittings Thermal insulation Subject to change without prior notice. 5 Hz EU / 9

2 65/,5-9 ATAC Solutions / Duty chart: Wilo-Yonos MAXO Pump curves /,5-1 1 Wilo-Yonos MAXO 1 5/3/,5-1 5/,5-1 8 /5/,5-8 5/3/,5-7 6 /,5-5/3/,5-1 5/, Subject to change without prior notice. 5 Hz EU 13-7 / 9

3 16 88 / Product list: Wilo-Yonos MAXO Type Pipe connection Nominal flange diameter Rated pressure Overall length Mains connection Gross weight Art no. PN / bar l / mm m / kg Yonos MAXO 5/,5-7 Rp ~3 V, 5/6 Hz Yonos MAXO 5/,5-1 Rp ~3 V, 5/6 Hz Yonos MAXO 5/,5-1 Rp ~3 V, 5/6 Hz Yonos MAXO 3/,5-7 Rp 1¼ ~3 V, 5/6 Hz Yonos MAXO 3/,5-1 Rp 1¼ ~3 V, 5/6 Hz Yonos MAXO 3/,5-1 Rp 1¼ ~3 V, 5/6 Hz 7 16 Yonos MAXO /,5- DN 6/1 1~3 V, 5/6 Hz Yonos MAXO /,5-8 DN 6/1 1~3 V, 5/6 Hz Yonos MAXO /,5-1 DN 6/1 5 1~3 V, 5/6 Hz Yonos MAXO 5/,5-8 DN 5 6/1 1~3 V, 5/6 Hz Yonos MAXO 5/,5-9 DN 5 6/1 8 1~3 V, 5/6 Hz Yonos MAXO 5/,5-1 DN 5 6/1 8 1~3 V, 5/6 Hz Yonos MAXO 65/,5-9 DN 65 6/1 8 1~3 V, 5/6 Hz Subject to change without prior notice. 5 Hz EU / 9

4 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-7 Pump curves v 1 3 Rp 1 m/s,5 1, 1,5,,5 Rp 1¼ Wilo-Yonos MAXO p/kpa 7 5/,5-7, 3/,5-7 1~3 V - Rp 1, Rp 1¼ Δp-c Δp-v 15,,8 1, 1,6, Q/l/s, 1m Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C Maximum permissible operating pressure Pipe connections P max C 1 bar Threaded pipe union Rp 1 Thread G 1½ Overall length l 18 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Dimension drawing G 1½ Protection class Insulation class IP XD F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 9 W Speed n 1-37 rpm Power consumption P W Current consumption I A Motor protection integrated Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Threaded cable connection PG Mx1.5 Materials L N PE SSM SSM: L1 L3 PE SSM L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Pump housing Grey cast iron (EN-GJL-) Impeller Plastic (PPE - 3% GF) Pump shaft Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m Subject to change without prior notice. 5 Hz EU 13-7 / 9

5 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-7 Information for order placements Make Wilo Type Yonos MAXO 5/,5-7 Art no Weight approx. m.5 kg Subject to change without prior notice. 5 Hz EU / 9

6 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-1 Pump curves v Rp 1 m/s,5 1, 1,5,,5 3, 3,5 Rp 1¼ Wilo-Yonos MAXO p/kpa 5/,5-1, 3/, ~3 V - Rp 1, Rp 1¼ Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) 6 6 Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max 1 bar 6 8,5 1, 1,5,,5 Q/l/s Δp-c Δp-v 15, 1m 1m m 6 8 1, Pipe connections Threaded pipe union Rp 1 Thread G 1½ Overall length l 18 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Dimension drawing G 1½ Protection class Insulation class IP XD F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 1 W Speed n 1 - rpm Power consumption P W Current consumption I A 18 Motor protection integrated Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Threaded cable connection PG Mx1.5 Materials Pump housing Grey cast iron (EN-GJL-) L N PE SSM SSM: L1 L3 PE SSM L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Impeller Plastic (PPE - 3% GF) Pump shaft Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m Subject to change without prior notice. 5 Hz EU / 9

7 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-1 Information for order placements Make Wilo Type Yonos MAXO 5/,5-1 Art no. 16 Weight approx. m.5 kg Subject to change without prior notice. 5 Hz EU / 9

8 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-1 Pump curves 1 8 v Wilo-Yonos MAXO 5/,5-1, 3/,5-1 1~3 V - Rp 1, Rp 1¼ Rp 1 m/s Rp 1¼ p/kpa 1 8 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) 6 6 Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max 1 bar Δp-c Δp-v 3,5 1, 1,5,,5 3, Q/l/s, 1m 11m 1m m 1m Pipe connections Threaded pipe union Rp 1 Thread G 1½ Overall length l 18 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Dimension drawing 6 6 G 1½ Protection class Insulation class IP XD F Mains connection 1~3 V, 5/6 Hz Nominal motor power P W Speed n 1-8 rpm Power consumption P W Current consumption I A 7 5 Motor protection integrated Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Threaded cable connection PG Mx1.5 Materials Pump housing Grey cast iron (EN-GJL-) L N PE SSM SSM: L1 L3 PE SSM L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Impeller Plastic (PPE - 3% GF) Pump shaft Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m Subject to change without prior notice. 5 Hz EU / 9

9 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-1 Information for order placements Make Wilo Type Yonos MAXO 5/,5-1 Art no. 161 Weight approx. m 5.3 kg Subject to change without prior notice. 5 Hz EU / 9

10 16 88 / Data sheet: Wilo-Yonos MAXO 3/,5-7 Pump curves v 1 3 Rp 1 m/s,5 1, 1,5,,5 Rp 1¼ Wilo-Yonos MAXO p/kpa 7 5/,5-7, 3/,5-7 1~3 V - Rp 1, Rp 1¼ Δp-c Δp-v 15,,8 1, 1,6, Q/l/s, 1m Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C Maximum permissible operating pressure Pipe connections Threaded pipe union P max C 1 bar Rp 1¼ Thread G Overall length l 18 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Dimension drawing G Protection class Insulation class IP XD F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 9 W Speed n 1-37 rpm Power consumption P W Current consumption I A Motor protection integrated Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Threaded cable connection PG Mx1.5 Materials L N PE SSM SSM: L1 L3 PE SSM L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Pump housing Grey cast iron (EN-GJL-) Impeller Plastic (PPE - 3% GF) Pump shaft Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m Subject to change without prior notice. 5 Hz EU / 9

11 16 88 / Data sheet: Wilo-Yonos MAXO 3/,5-7 Information for order placements Make Wilo Type Yonos MAXO 3/,5-7 Art no. 16 Weight approx. m.6 kg Subject to change without prior notice. 5 Hz EU / 9

12 16 88 / Data sheet: Wilo-Yonos MAXO 3/,5-1 Pump curves v Rp 1 m/s,5 1, 1,5,,5 3, 3,5 Rp 1¼ Wilo-Yonos MAXO p/kpa 5/,5-1, 3/, ~3 V - Rp 1, Rp 1¼ Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) 6 6 Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max 1 bar 6 8,5 1, 1,5,,5 Q/l/s Δp-c Δp-v 15, 1m 1m m 6 8 1, Pipe connections Threaded pipe union Rp 1¼ Thread G Overall length l 18 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Dimension drawing G Protection class Insulation class IP XD F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 1 W Speed n 1 - rpm Power consumption P W Current consumption I A 18 Motor protection integrated Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Threaded cable connection PG Mx1.5 Materials Pump housing Grey cast iron (EN-GJL-) L N PE SSM SSM: L1 L3 PE SSM L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Impeller Plastic (PPE - 3% GF) Pump shaft Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m Subject to change without prior notice. 5 Hz EU / 9

13 16 88 / Data sheet: Wilo-Yonos MAXO 3/,5-1 Information for order placements Make Wilo Type Yonos MAXO 3/,5-1 Art no. 163 Weight approx. m.6 kg Subject to change without prior notice. 5 Hz EU / 9

14 16 88 / Data sheet: Wilo-Yonos MAXO 3/,5-1 Pump curves 1 8 v Wilo-Yonos MAXO 5/,5-1, 3/,5-1 1~3 V - Rp 1, Rp 1¼ Rp 1 m/s Rp 1¼ p/kpa 1 8 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) 6 6 Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max 1 bar Δp-c Δp-v 3,5 1, 1,5,,5 3, Q/l/s, 1m 11m 1m m 1m Pipe connections Threaded pipe union Rp 1¼ Thread G Overall length l 18 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Dimension drawing 6 6 G Protection class Insulation class IP XD F Mains connection 1~3 V, 5/6 Hz Nominal motor power P W Speed n 1-8 rpm Power consumption P W Current consumption I A 7 5 Motor protection integrated Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Threaded cable connection PG Mx1.5 Materials Pump housing Grey cast iron (EN-GJL-) L N PE SSM SSM: L1 L3 PE SSM L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Impeller Plastic (PPE - 3% GF) Pump shaft Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m Subject to change without prior notice. 5 Hz EU / 9

15 16 88 / Data sheet: Wilo-Yonos MAXO 3/,5-1 Information for order placements Make Wilo Type Yonos MAXO 3/,5-1 Art no. 16 Weight approx. m 5. kg Subject to change without prior notice. 5 Hz EU / 9

16 16 88 / Data sheet: Wilo-Yonos MAXO /,5- Pump curves 5 v,,8 1, 1,6,, m/s Wilo-Yonos MAXO /,5-1~3 V - DN p/kpa 5 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) 3 3 Permitted field of application Temperature range at ambient temperature + C C 1 1 Maximum permissible operating pressure P max 6/1 bar 6 8 1,5 1, 1,5,,5 3, Q/l/s Δp-c 1 8 Δp-v 1, ,, 3, 3,, 1m 1,, Pipe connections Flange Combination flange PN6/1 (PN 16 flange according to EN 19-) Nominal flange diameter DN Overall length l mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Dimension drawing Emitted interference EN Interference resistance EN Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 9 W Speed n 1-37 rpm Dimension drawing, flange Ø 15 Ø 11 Ø 1 Ø 8 DN Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials 65 Pump housing Grey cast iron (EN-GJL-5) x Ø1 x Ø19 65 Impeller Pump shaft Plastic (PPS - % GF) Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU / 9

17 16 88 / Data sheet: Wilo-Yonos MAXO /,5- Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m L N PE SSM L1 L3 PE SSM Information for order placements SSM: L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Make Wilo Type Yonos MAXO /,5- Art no. 165 Weight approx. m 8.6 kg Subject to change without prior notice. 5 Hz EU / 9

18 16 88 / Data sheet: Wilo-Yonos MAXO /,5-8 Pump curves v,5 1, 1,5,,5 3, DN m/s,,8 1, 1,6, DN5 Wilo-Yonos MAXO p/kpa /,5-8, 5/,5-8 1~3 V - DN / Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max 6/1 bar Pipe connections 1 3 Q/l/s Δp-c 3 1 Δp-v 3 1m, Flange Combination flange PN6/1 (PN 16 flange according to EN 19-) Nominal flange diameter DN Overall length l mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Dimension drawing 6 6 Speed control Protection class Frequency converter IP XD Insulation class Mains connection F 1~3 V, 5/6 Hz Nominal motor power P W 135 Speed n 1-8 rpm Dimension drawing, flange Ø 15 Ø 11 Ø 1 Ø 8 DN 8 5 Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials 65 Pump housing Grey cast iron (EN-GJL-5) x Ø1 x Ø19 65 Impeller Pump shaft Plastic (PPS - % GF) Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU / 9

19 16 88 / Data sheet: Wilo-Yonos MAXO /,5-8 Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m L N PE SSM L1 L3 PE SSM Information for order placements SSM: L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Make Wilo Type Yonos MAXO /,5-8 Art no. 166 Weight approx. m 9. kg Subject to change without prior notice. 5 Hz EU / 9

20 16 88 / Data sheet: Wilo-Yonos MAXO /,5-1 Pump curves v 1 3 Wilo-Yonos MAXO /,5-1 1~3 V - DN m/s p/kpa Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Q/l/s Δp-c 3 1 Δp-v 1 11m 1m 1m, m 1m Dimension drawing Maximum permissible operating pressure Pipe connections Flange P max 6/1 bar Combination flange PN6/1 (PN 16 flange according to EN 19-) Nominal flange diameter DN Overall length l 5 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 35 W Speed n 95-5 rpm Dimension drawing, flange Ø 15 Ø 11 Ø 1 Ø 8 DN Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials 65 Pump housing Grey cast iron (EN-GJL-5) x Ø1 x Ø19 65 Impeller Pump shaft Plastic (PPS - % GF) Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU 13-7 / 9

21 16 88 / Data sheet: Wilo-Yonos MAXO /,5-1 Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m L N PE SSM L1 L3 PE SSM Information for order placements SSM: L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Make Wilo Type Yonos MAXO /,5-1 Art no. 167 Weight approx. m 13 kg Subject to change without prior notice. 5 Hz EU / 9

22 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-8 Pump curves v,5 1, 1,5,,5 3, DN m/s,,8 1, 1,6, DN5 Wilo-Yonos MAXO p/kpa /,5-8, 5/,5-8 1~3 V - DN / Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max 6/1 bar Pipe connections 1 3 Q/l/s Δp-c 3 1 Δp-v 3 1m, Flange Combination flange PN6/1 (PN 16 flange according to EN 19-) Nominal flange diameter DN 5 Overall length l mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Dimension drawing 6 6 Speed control Protection class Frequency converter IP XD 1 98 Insulation class Mains connection F 1~3 V, 5/6 Hz Nominal motor power P W 135 Speed n 1-8 rpm Dimension drawing, flange Ø 165 Ø 15 Ø 11 Ø 99 DN Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials 7 Pump housing Grey cast iron (EN-GJL-5) x Ø1 x Ø19 7 Impeller Pump shaft Plastic (PPS - % GF) Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU 13-7 / 9

23 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-8 Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m L N PE SSM L1 L3 PE SSM Information for order placements SSM: L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Make Wilo Type Yonos MAXO 5/,5-8 Art no. 169 Weight approx. m 1.5 kg Subject to change without prior notice. 5 Hz EU / 9

24 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-9 Pump curves,5 1, 1,5 8 6 v,,5 3, Wilo-Yonos MAXO 5/,5-9 1~3 V - DN 5 m/s p/kpa 8 6 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max 6/1 bar Δp-v Q/l/s Δp-c , 1m Pipe connections Flange Combination flange PN6/1 (PN 16 flange according to EN 19-) Nominal flange diameter DN 5 Overall length l 8 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Dimension drawing Emitted interference EN Interference resistance EN Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 35 W Speed n 95 - rpm Dimension drawing, flange Ø 165 Ø 15 Ø 11 Ø 99 DN Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials 7 Pump housing Grey cast iron (EN-GJL-5) x Ø1 x Ø19 7 Impeller Pump shaft Plastic (PPS - % GF) Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU 13-7 / 9

25 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-9 Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m L N PE SSM L1 L3 PE SSM Information for order placements SSM: L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Make Wilo Type Yonos MAXO 5/,5-9 Art no. 165 Weight approx. m 1. kg Subject to change without prior notice. 5 Hz EU / 9

26 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-1 Pump curves 1 v Wilo-Yonos MAXO 5/,5-1 1~3 V - DN 5 m/s p/kpa 1 8 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) 6 6 Permitted field of application Temperature range at ambient temperature + C C Δp-c 6 Δp-v 6 11m 1m 1m, m 1m Dimension drawing Q/l/s Maximum permissible operating pressure Pipe connections Flange P max 6/1 bar Combination flange PN6/1 (PN 16 flange according to EN 19-) Nominal flange diameter DN 5 Overall length l 8 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 5 W Speed n 95 - rpm Dimension drawing, flange Ø 165 Ø 15 Ø 11 Ø 99 DN Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials 7 Pump housing Grey cast iron (EN-GJL-5) x Ø1 x Ø19 7 Impeller Pump shaft Plastic (PPS - % GF) Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU / 9

27 16 88 / Data sheet: Wilo-Yonos MAXO 5/,5-1 Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m L N PE SSM L1 L3 PE SSM Information for order placements SSM: L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Make Wilo Type Yonos MAXO 5/,5-1 Art no Weight approx. m 1. kg Subject to change without prior notice. 5 Hz EU / 9

28 16 88 / Data sheet: Wilo-Yonos MAXO 65/,5-9 Pump curves 8 6 v,5 1, 1,5, Wilo-Yonos MAXO 65/,5-9 1~3 V - DN 65 m/s p/kpa 8 6 Approved fluids (other fluids on request) Heating water (in accordance with VDI 35) Water-glycol mixtures ( 1:1; above % admixture, the pumping data must be checked) Permitted field of application Temperature range at ambient temperature + C C Maximum permissible operating pressure P max 6/1 bar Δp-c 6 Δp-v , 1m Dimension drawing Q/l/s Pipe connections Flange Combination flange PN6/1 (PN 16 flange according to EN 19-) Nominal flange diameter DN 65 Overall length l 8 mm Motor/electronics Energy efficiency index (EEI).3 Electromagnetic compatibility EN Emitted interference EN Interference resistance EN Speed control Frequency converter Protection class IP XD Insulation class F Mains connection 1~3 V, 5/6 Hz Nominal motor power P 5 W Speed n 95 - rpm Dimension drawing, flange Ø 185 Ø 15 Ø 13 Ø 118 DN Power consumption P W Current consumption I A Motor protection integrated Threaded cable connection PG Mx1.5 Materials 8 Pump housing Grey cast iron (EN-GJL-5) x Ø1 x Ø19 8 Impeller Pump shaft Plastic (PPS - % GF) Stainless steel (X6Cr13) Bearing Carbon, metal impregnated Minimum suction head at suction port for avoiding cavitation at water pumping temperature Subject to change without prior notice. 5 Hz EU / 9

29 16 88 / Data sheet: Wilo-Yonos MAXO 65/,5-9 Terminal diagram 1~ 3 V, 5/6 Hz 3~3 V, 5/6 Hz Minimum suction head at 5 / 95 / 11 C.5 / 3 / 1 m L N PE SSM L1 L3 PE SSM Information for order placements SSM: L L3 L1 L Collective fault signal (NC contact according to VDI 381, load capacity 1 A, 5 V ~) For function, see Wilo catalogue, chapter "Pump management Wilo control, planning guide" Make Wilo Type Yonos MAXO 65/,5-9 Art no Weight approx. m 16.1 kg Subject to change without prior notice. 5 Hz EU / 9

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

Catalogue Wilo- Stratos PARA

Catalogue Wilo- Stratos PARA Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos

More information

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm] Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100 WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Submittal Data Sheet Wilo IPL - Inline Centrifugal Circulators

Submittal Data Sheet Wilo IPL - Inline Centrifugal Circulators Wilo IPL 1.5 175 RPM Project: Engineer: Contractor: Submitted By: Date: Approved By: Date: Tag # Model # Flow Head HP Cycle Phase Voltage RPM IPL 1.5-1/5-6Hz 1,75 ( Pole) 6 1 H[ft] H[m] Wilo-IPL 1.5-1/5-175

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

2- and 3-port valves with flanged connections, PN 10

2- and 3-port valves with flanged connections, PN 10 4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right

More information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

Vertical selfpriming Side-Channel Pumps Type WPV

Vertical selfpriming Side-Channel Pumps Type WPV Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

Simple to install, simply ready for the future Wilo Yonos PICO, Wilo Stratos PICO, Wilo Stratos. Information for installers

Simple to install, simply ready for the future Wilo Yonos PICO, Wilo Stratos PICO, Wilo Stratos. Information for installers Simple to install, simply ready for the future Wilo Yonos PICO, Wilo Stratos PICO, Wilo Stratos Information for installers 2 ErP Directive Everyone's talking about saving electricity We take action Advantages

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve

Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications

More information

SIGMA GROUP a. s. Divize průmyslová čerpadla

SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. INDUSTRIAL PUMP DIVISION Jana Sigmunda 79, 783 50 LUTÍN SEWAGE PUMPS NFPH, NFVH, NFJH, NFRH, NFPV, NFVV, NFJV, NFRV, NFPW NFVW Tel.: +420

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod.

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod. / Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev ev.a.a Ed./ ecocirc BASIC SERIES INSTALLA ALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Laing industrial pumps

Laing industrial pumps Laing industrial pumps... with spherical motor, robust and reliable! Normal suction centrifugal pumps! Self-priming pumps! Ecocirc DC pumps Summary Chapter Page Normal suction centrifugal pumps... 3 Application...

More information

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted

More information

Safety at a high level!

Safety at a high level! SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Heating, Air-conditioning, Cooling

Heating, Air-conditioning, Cooling Catalogue Building Services Heating, Air-conditioning, Cooling Pumps, pump systems and accessories for heating, secondary hot water, air-conditioning and cooling International edition 2011/2012-50 Hz APPLIES

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Hose and Tube Fittings Series 1-3

Hose and Tube Fittings Series 1-3 Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Automatic Bypass Control AVDO

Automatic Bypass Control AVDO Application AVDO is a self-acting constant flow control primarily used either to maintain minimum flow rates through e.g. a low-capacity gas boiler or to control the differential pressure in a central

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

SJT / SJM / SJP Large Vertical Pumps

SJT / SJM / SJP Large Vertical Pumps SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

SISTO-16TWA/HWA/DLU. Type Series Booklet

SISTO-16TWA/HWA/DLU. Type Series Booklet Diaphragm Valve SISTO-16TWA/HWA/DLU PN16 DN 15-200 Maintenance-free Flanged Ends Type Series Booklet Legal information/copyright Type Series Booklet SISTO-16TWA/HWA/DLU All rights reserved. The contents

More information

Operating Instructions for Plastic Flow Meter. Model: KSK

Operating Instructions for Plastic Flow Meter. Model: KSK Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity

More information

QLM and QLD Series Three-port Control Valves

QLM and QLD Series Three-port Control Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

RTD Temperature Probe for the Food/Pharmaceutical Industry

RTD Temperature Probe for the Food/Pharmaceutical Industry sales@jumo.co.uk Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K

More information

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor

More information

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6 Bimetallic steam trap CONA B Bimetallic steam trap Bimetallic steam trap PN16 - with flanges (Fig. 600...1) - union with butt weld ends (Fig. 600...5) Grey cast iron Fig. 600 Page 2 Bimetallic steam trap

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

ARI-ASTRA / ASTRA Plus Combinend flow regulating valve

ARI-ASTRA / ASTRA Plus Combinend flow regulating valve ARI-ASTRA - Free of maintenance combinend flow regulating valve - soft sealed (to 120 C) ARI-ASTRA Plus - Free of maintenance combinend flow regulating valve (to 175 C resp. 350 C) ARI-ASTRA / ASTRA Plus

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

Type 3353 Angle Seat Valve

Type 3353 Angle Seat Valve Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

VAD Variable Area Desuperheaters

VAD Variable Area Desuperheaters Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01) VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

Replacement Guide Heating

Replacement Guide Heating Replacement Guide Heating Wilo Circulators for Heating and Secondary Hot Water Circulation ab 1975 September 2006 Energy efficiency class A. Also for one- and two-family homes. Up to 80 % power savings.*

More information

Pumps n Valves n Service. The right partner for your project. Heating, ventilation and air-conditioning

Pumps n Valves n Service. The right partner for your project. Heating, ventilation and air-conditioning Pumps n Valves n Service The right partner for your project. Heating, ventilation and air-conditioning 02 Introduction Always the right solution It is not only large projects that place high demands on

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

The right partner for your project. Heating, ventilation and air-conditioning

The right partner for your project. Heating, ventilation and air-conditioning Our technology. Your success. Pumps n Valves n Service The right partner for your project. Heating, ventilation and air-conditioning 02 Introduction Always the right solution It is not only large projects

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP Application Tight-closing butterfly valve for process engineering and industrial applications DN 50 to 300 NPS 2 to 12 Nominal pressure PN 10

More information